Home
4030 Pulse Generator User Manual
Contents
1. As a pulse period time select switch it has a 8 range of 100ns 10s Also by the crystal oscillator 10MHz 1MHz 100KHz 10KHz 4KHz 100Hz 10Hz and 1Hz Note If using manual trigger 10 MHz must be selected i Manual trigger is not available in any other rate ranges 10 MODE X TAL It is a standard frequency oscillator mode select it is generated the standard frequency by crystal oscillator circuit INT RATE As a internal trigger mode switch to trigger the pulse circuit by internal oscillator frequency and rate is controlled by the RATE pot EXT TRIGGER Ext Trigger rising falling edge selector MAN TRIGGER Manual trigger mode selector Manual trigger available only when rate is set to 10 MHz 100 ns only Not available with other rate ranges 11 POWER ON SWITCH 4 3 PRECAUTIONS This is a Power ON OFF switch To obtain the optimum performance of the 4030 the following procedure should be adopted cios MAINS SELECTOR FUSE DISCONNECT BEFORE CHANGING RANGE OR REPLACING FUSE CAUTION FOR CONTINUED PROTECTION AGAINST FIRE REPLACE ONLY 5 E SELECTED VOLTAGE AND CURRENT RATINGS MAINS IN Fig 2 Rear Panel Controls 12 PUSH ON SWITCH One pulse is generated when push the button under mode setting of manual trigger position 2 Do not operate the instrument where mechanical vibrations are excessive or near a instrument which generates strong electric or magnetic fiel
2. BK PRECISION Instruction Manual Model 4030 10MHz Pulse Generator WARRANTY CARD BK Precision certifies that all products manufactured conform to published specifications and are free from defects in materials and workmanship for a period of One 1 year from the date of delivery when used under normal operating conditions and within the service conditions for which they were furnished The obligation of BK Precision arising from a Warranty claim shall be limited to repairing or at its option replacing without charge any product which in BK Precision sole opinion proves to be defective within the scope of the Warranty BK Precision must be notified in writing of the defect or nonconformity within the Warranty period and the affected product returned to BK Precision within 30 days after discovery of such defect or nonconformity Although Quick Servicing Guidelines are provided in the manual the unit doesn t contain any user serviceable parts BK Precision shall have no responsibility hereunder for any defect or damage caused by improper storage improper installation unauthorized modification neglect inadequate maintenance accident or for any product which has been repaired or altered by anyone other than BK Precision EXCLUSION OF OTHER WARRANTIES The Warranty described above is Buyer s sole and exclusive remedy and no other warranty whether written or oral is expressed or implied BK Precision specifically desclaims the
3. Width switch and the time division switch on your O Scope match There will come a point where the trigger is too fast for your eye to view it using an analog scope If you leave the time division at 500mS or 50mS you will be able to view faster pulses but it will be a very dim and quick dot and you will have to look closely to see it but once again verify the pulse by the counter It should go up 1 every time you push the button
4. ds 1 Select a location free from dust and humidity REAR PANEL CONTROLS 3 Ensure that proper mains voltage 115V AC or 230V AC is selected 1 TRIGGER IN BNC Failure to do so may permanent damage the instrument The maximum input of trigger input BNC connector is 10Vp p 2 FUSE This is a fuse in series with mains supply For 230V 250mA amp For 115V 500mA 3 BNC SYNC OUT rs As a trigger out BNC connector output impedance is 50 ohms with TTL level output 13 4 4 TROUBLESHOOTING Using Manual Trigger In order to use the manual trigger you must have the Rate switch in the 10M 100nS position This is the only way to access the manual trigger function If you set the Rate switch to the 10M position and the Width switch to the 50mS and the Mode switch to manual trigger then set the volt division switch on your O Scope to 2V or 5V and your time division respectively at 50mS When you push the manual trigger you will see a 50mS pulse one division horizontally You may have to push it a couple of times because sometimes the trigger pulses off the screen To verify that the pulse is actually triggering you can hook the unit up to a counter that has a Total feature Every time you push the trigger the counter will count 1 pulse If you change your volts division switch to 500mS and leave all the other settings the same as above you will see the pulses very clearly To continue viewing the trigger make sure that the
5. e rating can result in fire amp or serious damage or harm to human life amp property 1 3 A Refer to Manual 2 1 2 2 Section 2 Technical Specifications FREQUENCY RANGE Internal Stability Internal Mode X tal Spot Frequencies Stability X tal Mode Warm up Time TRIGGERING Internal External Manual Ext Trig Input Trig Output a 0 1Hz to 10MHz in 8 decade ranges amp variable 0 5 10MHz 1MHz 100KHz 10KHz 1KHz 100Hz 10Hz 1Hz 200 ppm 30 minutes 0 1Hz to 10MHz 10Hz to 10MHz 1 pulse out for each switch press 1V to 10V p p sine amp square waveform TTL pulse Zo 50 ohms Manual trigger available for 10 MHz 100 ns rate only Not available with any other rate settings 2 3 2 3 2 4 2 5 FREQUENCY COUNTER Range Display Display Accuracy RATE WIDTH DELAY 0 1Hz to 10MHz 4 digit counter with Internal External and Auxiliary mode 10 5 1 count 100nsec 0 1sec 8 decade range 8 variable adj 50nsec 50msec 0 decade range and variable 0 2usec variable w r t trigger output 2 6 2 7 2 8 2 9 3 1 OUTPUT POLARITY Normal Inverting OUTPUT Pulse Out 0 5V 5V at 50 ohms Impedance 50 ohms Rise amp Fall Time 12nsec Output Terminal BNC connector POWER SUPPLY Voltage 115V 8 230V AC 110 47Hz 63Hz switchable Consumption 10VA PHYSICAL 10 8x 3 4 x 12 2 275 x 86 x 310 mm approx Dimensions WxHxD W
6. eight 6 6 Ibs 3 Kgs approx Section 3 General Description INTRODUCTION BK Precision s Pulse Generator Model 4030 is specifically designed to include only the basic facilities of a Pulse Generator in order to make it handy and easy to operate unit It offers pulse repetition rate from 0 1Hz to 10MHz with rise amp fall time lt 12nsec pulse width from 50nsec to 50msec amp pulse amplitude from 0 5V to 5V across 50 ohms Provision for external triggering and monopulse generation is also done 3 2 3 3 3 4 3 5 See The x tal mode gives accurate eight spot frequencies derived from 10MHz crystal source This manual contains information pertaining to the specifications installation and operation of Pulse Generator Model 4030 APPLICATIONS The name Pulse Generator tends to conjure up images of an instrument that is primarily intended for use with digital circuit The generator can be used to test the digital circuits to provide noise free pulse to define the resonant frequency of the L C circuit defining R C times testing the quality of power supply to test power amplifiers Naturally the most common application of the 4030 pulse generator is in the design testing and servicing of circuits that normally use pulse signals especially digital logic circuits The 4030 can generate the same type of signal as normally used in the circuit for signal substitution or signal tracing methods of troubleshooting The pulse generator is use
7. ful when driving circuitry that cannot accept negative voltages An oscilloscope is normally used to examine the output of the circuit while the pulse generator supplies the input INSTALLATION DATA The instrument is shipped ready for bench operation The front panel must remain unobstructed to allow cable connections and switch knob operation Do not throw the packing material as it can be useful while returning the instrument to factory for calibration servicing POWER REQUIREMENTS Mode 4030 has a three conductor self power cord that grounds the instrument chassis when connected to a compatible power receptacle The instrument operates over a nominal 115V amp 230V AC 10 47Hz 63Hz supply INCOMING CONFIDENCE CHECK Prior to packaging the instrument for shipment extensive operational and calibration procedures were performed to verify conformity to specifications To ensure the electronic integrity of the instrument you must perform the following confidence check 3 6 3 7 3 8 4 1 Adjust the settings by using range select switch and controls 1 Model Select X TAL 2 Rate s 1MHz 3 Width s 50ns to 500ns 4 Width Control Minimum 5 Output Maximum Check the output pulse waveform on oscilloscope Check all the controls and Polarity control ACCESSORIES 1 BNC to BNC 1 No 2 50 ohms Termination 1 No 2 Operation Manual 1 No CLEANING As an electronic instrument due ca
8. implied warranties of merchantability and fitness for a particular purpose No statement representation agreement or understanding oral or written made by an agent distributor representative or employee of BK Precision which is not contained in the foregoing Warranty will be binding upon BK Precision unless made in writing and executed by an authorized BK Precision employee Under no circumstances shall BK Precision be liable for any direct indirect special incidental or consequential damages expenses losses or delays including loss of profits based on contract tort or any legal theory MODEL NO OF THE INSTRUMENT 4030 SR NO OF THE INSTRUMENT Section 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 4 1 4 2 4 3 Contents Description SAFETY INSTRUCTIONS SPECIFICATIONS GENERAL DESCRIPTION introduction Applications Installation Data Power Requirements Incoming Confidence Check Accessories Cleaning Storage OPERATING INSTRUCTIONS amp ADJUSTMENTS Front Panel Controls Rear Panel Controls Precautions Section 1 Safety Instructions 1 1 Prior to applying power to the instrument ensure that earth is available at the power outlet Intentional interruption of the grounding system by use of two wire plug adapters or two wire extension cords must be considered an unsafe practice 1 2 Be sure that only correct power fuse with required V I ratings is installed for replacement purpose Incorrect fus
9. re should be taken to keep the instrument away from dusty environment The customer is advised to clean only the external part of the instrument with a soft moist cloth Special care should be taken while cleaning the front panel No chemicals or solvents must be used to clean the instrument STORAGE There are no special instructions for storage The instrument should be shelved in a reasonably clean environment and protected from dirt and moisture Do not wrap airtight with plastic Section 4 Operating Instructions amp Adjustments FRONT PANEL CONTROLS The front panel controls are functionally grouped and clearly designated for ease of operation Their functions are described below 1 DISPLAY This 4 digit 7 segment display indicates rate frequency 2 RATE Variable The period is short at MIN position counter clockwise and period is long at MAX position as a pulse period or frequency variable controller 3 DELAY Variable To delay the pulse out against trigger output The variable limit is 0 248 4 WIDTH To control the pulse width 5 OUTPUT LEVEL POT Pulse output level controller 1V 10V DELAY EXT EXT wr aes MAH Fig 1 Front Panel Controls 6 POL Output polarity select switch of pulse 7 OUTPUT BNC CONNECTOR The pulse out BNC connector with output impedance of 50 ohms 8 WIDTH S RANGE As a pulse width time select switch it has a 5 range of 50ns 5ms 9 RATE S RANGE
Download Pdf Manuals
Related Search
Related Contents
Unicol VBR mounting kit APC SurgeArrest Essential Patriot Memory 2GB DDR2 240-pin DIMM Kit User Manual - tailoredPOS Manual - Conceito Tecnologia Zebra TLP 3844-Z Whistler 1788 Radar Detector User Manual Delta Meter User's Manual A101 User`s Manual Copyright © All rights reserved.
Failed to retrieve file