Home

Ziton survey kit user guide v3 - Utcfssecurityproductspages.eu

image

Contents

1. Survey Kit User Guide Contents 1 0 INTRODUCTION ounuausa nun a a na una 3 1 1 Identification of partS ae ae ee TEL Re RG 4 152 UNE EAU ee ee aaa 5 2 0 BEFORE YOU START THE SURVEY zunuununnnnunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nun 6 3 0 STEP BY STEP SURVEY GUIDE 1 aus a 8 3 1 How to Carry out the site survey ar ge 8 3 1 1 Results display explained sssnssssssssssnsnsnssnsnenssssnnnsnsersnsnenessnnnnnneenen 11 4 0 CHARGING AND BATTERY REPLACEMENT uzuuuuuuunununnnnunnnnnnnnnnnnnunnnn 12 SO DIAGNOSTICS oirinn EAEE 12 6 0 QUICK SURVEY GUIDE sunsn ia a aa ar 13 7 0 SURVEY RECORD FORM wiisieceidscicsacivententdeedesecdasanssnwatabenntesicewedaneedesenes 14 EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Technical Helpline Tel 44 0 8712 710804 Email enquiries emsgroup co uk Website www emsgroup co uk Ziton Survey kit user guide Iss 3 2 1 0 INTRODUCTION e This manual provides a guide to using the Ziton Radio Survey Kit e The survey kit should be used to determine the radio equipment requirements for the site to ensure that full radio coverage for the areas concerned is achieved with the required signal strengths for reliable communication e The survey will create the footprint for the installed system specifying the final positions for the devices and radio infrastructure e The installed Ziton radio system comprises of a Radio Loop Interface capable of receiving infor
2. andle On Off Keyswitch LCD Display USB Connection Power LED Indicator Transmit and Receive LED indicators Charger Connection EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Technical Helpline Tel 44 0 8712 710804 Email enquiries emsgroup co uk Website www emsgroup co uk Ziton Survey kit user guide Iss 3 5 2 0 BEFORE YOU START THE SURVEY Before you start surveying the premises there are a number of points to take into consideration that will aid the survey These are as follows 1 Identify where the Loop Interface is to be installed on the loop cabling This is the starting point of the radio infrastructure and where you should position your Signal Surveyor 2 Remember to achieve maximum signal range the Loop Interface should be installed 600mm away from metal objects and other equipment and 2 metres from electrical equipment This allows free space around the Loop Interface s internal aerials 600mm AWAY FROM METAL 2m AWAY 2m AWAY FROM OTHER FROM OTHER ELECTRICAL mon ELECTRICAL EQUIPMENT EQUIPMENT 2m AWAY FROM OTHER ELECTRICAL EQUIPMENT 300mm is an acceptable distance where 600mm is not acheivable 3 Consider positioning your Loop Interfaces centrally giving as much 360 degree coverage as possible Interface Pos
3. enquiries emsgroup co uk Website www emsgroup co uk Ziton Survey kit user guide Iss 3 9 STEP 5 The survey poles should be attached to the device survey tool so that tests can be carried out at ceiling level for detectors and against the wall for Callpoints and Sounders STEP 6 Present and hold the device survey tool against the wall or ceiling in the position of the proposed installed device l Device proposed position Device proposed position STEP 7 The unit will beep to indicate a test has started After a few seconds results will be displayed and a high pass or a flat fail tone will be heard LED signal indication is also shown on the device a Green LED indicates a Pass and the Yellow LED indicates a Fail EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Technical Helpline Tel 44 0 8712 710804 Email enquiries emsgroup co uk Website www emsgroup co uk Ziton Survey kit user guide Iss 3 10 STEP 8 Remove the device survey tool from the survey position and record the displayed results An example display is shown below Alternating to Note A level of 24dB or above is required as a pass result Note The background levels are taken into account prior to displaying the events on the units If the required device position fails to pass the test then a further Loop Interface position will need to be found closer to the device and the survey repeated Every dev
4. i GREATER THAN24dB DIN ZINN p __ GREATER THAN GREATER 24dB mm THAN24dB ZINN ZINN LOOP INTERFACE 3 1 How to carry out the site survey STEP 1 Position the surveyor at the proposed position of the Loop Interface EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Technical Helpline Tel 44 0 8712 710804 Email enquiries emsgroup co uk Website www emsgroup co uk Ziton Survey kit user guide Iss 3 8 STEP 2 Switch on the surveyor using the keyswitch on the side of the unit After a few seconds the surveyor display will indicate the background signal level for that particular position The level is displayed in dB and its range is 0 100 The signal should be as low as possible 21 100 11 20 0 10 Therefore it may be necessary to try multiple positions to obtain the lowest background level Example displays are shown below sackeroud oo Ay Inncisreuma aoan l x STEP 3 The background levels should be noted for future reference This can be recorded using the forms at the back of this manual STEP 4 Switch the device survey tool on using the switch located on the front of the unit The tool will then display that it is ready for use Press switch upwards as shown to switch unit on EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Technical Helpline Tel 44 0 8712 710804 Email
5. ice position should be recorded along with the received signal levels 3 1 1 Results display explained The figures shown are explained as follows Signal strength Signal strength Pass or Fail signal Total Number received by the Signal received by the Device result displayed of tests Surveyor from the Survey Tool from the conducted Device Survey Tool in Signal Surveyor in dB dB Alternating to Background Signal success rate Signal success rate Level in dB Surveyor Survey device received by the Device received by the Device Battery Battery Survey Tool from the Survey Tool from the Signal Surveyor in Signal Surveyor in gt 45dB Pass EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Technical Helpline Tel 44 0 8712 710804 Email enquiries emsgroup co uk Website www emsgroup co uk Ziton Survey kit user guide Iss 3 11 4 0 CHARGING AND BATTERY REPLACEMENT The surveyor unit is supplied with a mains charger It can also be left connected if necessary during the survey process The rated charging voltage is between 100 230Vac 10 0 3A at 45 65Hz The surveyor unit can be charged with the keyswitch either in the on or off position Caution The keyswitch does not disconnect the unit from the mains supply If the internal battery shown below should require replacement please ensure the correct polarity connections are used as marked on the battery Y4 6 6V 4Ah C20 red wire posit
6. ition EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Technical Helpline Tel 44 0 8712 710804 Email enquiries emsgroup co uk Website www emsgroup co uk Ziton Survey kit user guide Iss 3 6 4 Remember when choosing a location the Loop Interfaces require a loop in and out cable connection and a maximum of two interfaces per loop are allowed Interface 1 ZONES LII III LITT IT LI II II LIT III 07 Saeeee88 LIT III as 5 Remember the Loop Interfaces can have a maximum of 31 devices allocated to each individual Interface m 2 ZN Maximum 31 Radio Devices Interface 1 ZI 2 ZN DIN EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Technical Helpline Tel 44 0 8712 710804 Email enquiries emsgroup co uk Website www emsgroup co uk Ziton Survey kit user guide Iss 3 7 3 0 STEP BY STEP SURVEY GUIDE The step by step survey guide shown in this section should be used as a guideline only A Quick Guide is also shown in section 6 of this manual The main point to consider is to ensure that all field devices have signal strengths over 24dB All Devices have valid communication paths of over 24dB Pass Result GREATER THAN 24dB GREATER THAN 24dB Im NG 2 MM ZU LOOP INTERFACE m m
7. ive black wire negative The Surveyor Device shown below requires 4 x AA MN1500 LR6 1 5V Batteries Please ensure batteries are installed in the correct polarity as shown on the device case Battery Y4 6 6V 4Ah C20 5 0 DIAGNOSTICS The surveyor box is equipped with a USB port This is used for factory programming and diagnostics purposes The port can be used in conjunction with Windows Hyper Terminal used in capture mode This can provide a real time text file of the survey and will output the test results every time a new position is tested A USB lead and drivers would be required to use this feature For further details please contact EMS technical support on 08712 710804 USB Port Type B EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Technical Helpline Tel 44 0 8712 710804 Email enquiries emsgroup co uk Website www emsgroup co uk Ziton Survey kit user guide Iss 3 12 6 0 QUICK SURVEY GUIDE Position the surveyor in the proposed Loop Interface location Turn on surveyor Note background level displayed and record for future reference Turn on the Device survey tool Position the Device survey tool against the wall or ceiling in the positions of the proposed radio devices Record signal levels displayed Repeat steps 5 6 for all device positions associated with the Loop Interface position If there are multiple Loop Interface positions on si
8. land Technical Helpline Tel 44 0 8712 710804 Email enquiries emsgroup co uk Website www emsgroup co uk Ziton Survey kit user guide Iss 3 3 1 1 Identification of parts e Device Survey Tool 1 per kit This part of the survey equipment is used to mimic the installed device s signal strength The unit works in conjunction with the Signal Surveyor to mimic the achievable range between the device and Loop Interface position e Signal Surveyor 1 per kit This part of the survey equipment is used to mimic the installed Loop Interface to radio device s achievable range e Device Survey Pole 6 per Kit The survey poles are used for connection into the Device Survey Tool This allows results to be taken from device locations which are out of reach e Signal Surveyor mains charger 1 per Kit The mains charger is used for connection into the Signal Surveyor units for recharging the devices onboard battery EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Technical Helpline Tel 44 0 8712 710804 Email enquiries emsgroup co uk Website www emsgroup co uk Ziton Survey kit user guide Iss 3 4 1 2 Unit Features Device Survey Tool Depress switch to ECR initiate test signal Display Green LED Signal Pass indicator Battery compartment and On Off j cover Switch Yellow LED Signal Fail indicator Survey Pole attachment Signal Surveyor Carrying H
9. mation from a maximum of 31 radio devices The radio devices include Multisensor detectors along with manual callpoints sounders sounder beacons and input output units e The communication between devices to the interface is bi directional and utilises the 868Mhz frequency e The Ziton Loop Interface is capable of connection to a ZP Protocol Fire Alarm Control Panel via its Loop in and Loop out connection terminals The interface is addressed on the loop via its onboard 8 way DIP switch A total of 2 Loop Interfaces per loop can be fitted onto a Fire Alarm Control Panel e Each site will have a level of background noise that may affect the signals on site Under EN54 25 Fire detection and fire alarm systems Components using radio links the minimum signal headroom must be checked to ensure reliable communication This is essential to ensure immunity against site attenuation caused by environmental changes and other electrical equipment e It is recommended that the survey results along with the background are recorded for future reference The survey kit automatically calculates the required headroom and then displays the results The results are displayed by showing as a Pass or Fail System Overview m m p __ ee Zi ZI ZI m _ IHN m e o EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ Eng
10. te required repeat steps 1 7 for each Interface Please remember when carrying out the survey Note 1 A maximum of 31 devices can be allocated to a single Interface Note 2 A maximum of 2 Loop Interfaces per fire alarm panel loop EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Technical Helpline Tel 44 0 8712 710804 Email enquiries emsgroup co uk Website www emsgroup co uk Ziton Survey kit user guide Iss 3 13 7 0 SURVEY RECORD FORM Site Date Loop Interface Number Background dB EEE DE HE HE EEE HE HE EEE EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Technical Helpline Tel 44 0 8712 710804 Email enquiries emsgroup co uk Website www emsgroup co uk Ziton Survey kit user guide Iss 3 14