Home

BlackBond User`s Guide - Engage Communication, Inc.

image

Contents

1. Gil cngag tion BlackBond User s Guide Engage Communication Inc 9565 Soquel Drive Aptos California 95003 Ph 1 831 688 1021 Fax 1 831 688 1421 www engageinc com Rev 062407 Seller warrants to Buyer that any unit shipped to Buyer under normal and proper use be free from defects in material and workmanship for a period of 24 months from the date of shipment to Buyer This warranty will not be extended to items repaired by anyone other than the Seller or its authorized agent The foregoing warranty is exclusive and in lieu of all other warranties of merchantability fitness for purpose or any other type whether express or implied A All claims for breach of the foregoing warranty shall be deemed waived un less notice of such claim is received by Seller during the applicable warranty period and unless the items to be defective are returned to Seller within thirty 30 days after such claim Failure of Seller to receive written notice of any such claim within the applicable time period shall be deemed an absolute and unconditional waiver by buyer of such claim irrespec tive of whether the facts giving rise to such a claim shall have been discovered or whether processing further manufactur ing other use or resale of such items shall have then taken place B Buyer s exclusive remedy and Seller s total liability for any and all losses and damages arising out of any cause whatsoever whether such cause be based in contract neg
2. T1 Coding B8ZS T1 TxUnderrunAIS Off Interface S2 Type T1 T1 Data Normal T1 Framing ESF T1 Coding B8ZS T1 TxUnderrunAIS Off Interface S3 Type T1 T1 Data Normal T1 Framing ESF T1 Coding B8ZS T1 TxUnderrunAIS Off Chapter 2 Installation QuickStart Engage Communication Example BlackBond T1 FRACTIONAL BlackBond Link Encryptor User s Guide BlackBonds are connected to external T1 WAN circuit that is the T1 clock source Host Name BlackBond Master Host Contact No contact specified Host Location No location specified Telnet On UserTimeout 0 SNMP Off SNMP Traps Off Interface LAN 1 AutoNeg On IP Address 192 168 1 50 24 IP Default router 0 0 0 0 Port On BroadcastRcv On Security AES On Rekey On Rekey Mode Master Rekey Period 1 Day ClockMaster TEL2 Network Channels 1 8 Interface S1 Type T1 T1 Data Normal T1 Framing ESF T1 Coding B8ZS T1 TxUnderrunAIS Off Interface S2 Type TI T1 Data Normal T1 Framing ESF T1 Coding B8ZS T1 TxUnderrunAIS Off Interface S3 Type T1 T1 Data Normal T1 Framing ESF T1 Coding B8ZS T1 TxUnderrunAIS Off Host Name BlackBond Slave Host Contact No contact specified Host Location No location specified Telnet On UserTimeout 0 SNMP Off SNMP Traps Off Interface LAN 1 AutoNeg On IP Address 192 168 1 50 24 IP Default router 0 0 0 0 Port On BroadcastRcv On Security AES On Rekey On Rekey Mode S
3. government is subject to restrictions set forth in subparagraph c 1 ii of the Rights in Technical Data and Computer Software clause in DFARS 52 227 7013 and in similar clauses in the FAR and NASA FAR Supplement Information in this document is subject to change without notice and does not represent a commitment on the part of Engage Communication Inc FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operat ed in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense NOTE Shielded Telecommunication T1 or E1 and ethernet cables must be used with the Engage IP Tube to ensure compli ance with FCC Part 15 Class A limits CAUTION To reduce the risk of fire use only No 26 AWG or larger listed Telecommunication cables Equipment Malfunction lf trouble is experienced with an IP Tube please contact the Engage Communication Service Center If the equipment is Causin
4. the BlackBond can be mounted in a standard 19 inch equipmen rack rack mounts are available from Engage Powering the BlackBond Engage BlackBond units utilize an external power adapter providing DC output The appropriate power adapter is provided with each unit e Ensure the power adapter is not connected to power e Plug the AC adapter into the POWER connector e Connect the power adapter to an appropriate AC power outlet Check the POWER LED on the front panel of the Engage BlackBond The internal diagnostics will then proceed Console Port All BlackBond models include a Console port for configuration The Console port may be used for serial communication from a local workstation or remote LAN via a modem BlackBond models utilize an RJ45 jack for the Console port The Console port is configured as a DTE Data Terminal Equipment port This allows direct connection to a DCE Data Communication Equipment device such as a modem An RJ45 to DB9 adapter is provided with the BlackBond which in addition to providing a physical interface performs the null modem operation permitting direct connection to other DTE equipment such as the COM ports of a PC Pinouts for the Console port as well as Engage supplied adapters are provided in the Appendices Communication to the console port should be set for 9600 baud 1 stop bit no parity 8 bit fixed flow control none Once a serial connection between a workstation and the BlackBond C
5. tive information transmitted over T1 or E1 communication links Key Management The command GENKEY generates an encryption key for use on the local and the remote BlackBond units to assure automated key management for timely key transitions The ENTER KEY command is used to place the key code on both units for encryption and unencryption of data pass ing between nodes 2 Chapter 1 Introduction Engage Communication i B lackBond Link Encryptor User s Guide BlackBond Physical Interfaces Console Port A console port is provided for Terminal access to the unit such as that provided by the COM inter faces of personal computers LAN Interface The BlackBond T1 E1 has a 10 100BaseT interface for local or remote management T1 E1 Interface The Standard BlackBond has 2 T1 E1 DSU CSU interfaces with lightning protection circuitry one for plain text T1 E1 connections the other for encrypted T1 E1 Indicators reveal the port s availability link status and encryption status Optionally a BlackBond can be ordered with a secondary or tertiary T1 E1 WAN interfaces for WAN connection redundancy 3 Chapter 1 Introduction Chapter 2 Installation QuickStart This QuickStart Chapter is intended for users who understand how they want their BlackBond in stalled and configured and only require the mechanics of performing that configuration Communication with the BlackBond Link Encryptor Console Port Telnet Initial communicat
6. CRC4 FAS E1 Coding HDB3 AMI E1 IdleCharacter value E1TxUnderrunsAIS On Off E1 Channels Full Fractional Note Improper configuration of the T1 E1 clocking will result in an overrun or under run condition which causes T1 E1 periodic frame losses One of the BlackBond units must be the master clock source or locked onto a master and the remote end unit uses the network to match the master s T1 E1 clock frequency In the case where a BlackBond is being connected to a T1 E1 line from the Tele phone company the unit connected to the Telco T1 E1 line must be set to T1 E1 Clocking Network Refer to the BlackBond Clocking description that follows 6 Chapter 2 Installation QuickStart Engage Communication BlackBond Link Encryptor User s Guide BlackBond Clocking The BlackBond CLOCKMASTER command is used to set the clocking source TEL1 or TEL2 for the units When TEL1 is chosen as CLOCKMASTER TEL1 provides the clocking source for TEL2 When TEL2 is chosen TEL2 provides the clocking for TEL1 CLOCKMASTER TEL1 TEL2 NETWORK INTERNAL This determines the source of Transmit Clock for the port TEL1 or TEL2 selected by CLOCKMAS TER When set to NETWORK the DSU CSU derives its transmit timing from the port s receive data and is therefore synchronized with the telco the telephone network This is generally used when connecting through commercial carriers When set to INTERNAL the port transmits data at a rate set by an
7. E1 configuration and the BlackBond may need to be set to Full T1 E1 on its interface S1 to thor oughly test the connection A typical problem with T1 E1 circuit extension is the misconfiguration of the Fractional T1 E1 DSOs BlackBond IP Interconnect Verification The most straight forward way to test the T1 E1 Circuit of the BlackBond is to have them connected into the same Ethernet Hub with unique IP addresses that are within the same subnet For Example set one of the BlackBonds to 192 168 1 1 and the other to 192 168 1 2 Note Once a BlackBond has Chapter 6 Troubleshooting Engage Communication BlackBond Link Encryptor User s Guide determined the Mac Ethernet Address of the remote unit it requires a reset to obtain the Mac Ether net Address of a substitute unit BlackBond Off Net IP Interconnect Verification In most applications the BlackBond will be located on different IP networks and the interconnection is through a routed connection At each end of the routed connection the BlackBond s default router IP address needs to be pointed to the first router in the path to that remote IP subnet Through a Telnet connection to an BlackBond it is possible to verify the ability of the BlackBond to ping its local default router and to ping the remote BlackBond Note the console port does not support the Ping Com mand as it does not have an IP Address Show Statistics The CLI command SHOW STATISTICS provides a way to check whether the T1O
8. Internal clock This mode is usu ally used when testing on the bench In a Bench configuration one unit s CLOCKMASTER is TEL1 with NETWORK Timing This unit derives it s clocking from the telco and passes that clocking on to TEL2 The other unit s CLOCKMAS TER is TEL2 which is connected to the TEL2 port of the first unit This second unit has its TEL2 set to CLOCKMASTER TEL2 NETWORK which means it derives its clocking from the first BlackBond via TEL2 and passes it to TEL1 When the T1 E1 WAN is provided by a Service provider most likely clocking needs to be derived from the T1 E1 circuit This is done by setting both BlackBonds to have their clocking from the TEL2 inter face with this configuration CLOCKMASTER TEL2 NETWORK Note the TPS Protection switch TEL3 interface uses the TEL2 clocking configuration Note Improper configuration of the BlackBond clocking will result in an overrun or underrun condition which causes T1 E1 periodic frame losses BlackBond System Parameters Host Name BlackBond Master Host Contact No contact specified Host Location No location specified Telnet On Off UserTimeout 0 SNMP On Off SNMP Traps On Off Ethernet IP address An IP address is needed when commnication with the BlackBond is done via an ethernet connection to your network Assign a unique IP address to each unit wth the command IP ADDRESS IP ADDRESS aaa bbb ccc ddd Note BroadcastRCV must always be on Def
9. network This is generally used when connecting through commercial carriers Note Connection of the BlackBonds to an T1 E1 circuit that is clock source is done by having both Chapter 5 BlackBond T1 E1 Configuration and Operation BlackBonds configured to derive their transmit clocking from the T1 E1 WAN interface TEL2 This is done by having CLOCKMASTER TEL2 NETWORK on both BlackBonds When a BlackBond is set to INTERNAL it transmits data using its internal clock This mode is usually used when testing on the bench one unit is considered the Clock Master the other Clock Slave In the case of setting Clocking on the remote unit is received from the Master unit The remote or secondary unit should be set to receive it s clocking on TEL2 the port used to receive data from the Master The first unit therefore receives it s timing from an outside source and the second unit re ceives it s timing from the Master unit If the clockmaster is TEL2 then the TEL3 clock source is determined by the network internal param eter TYPE T1 E1 The TYPE parameter should be set to T1 or E1 depending on the equipment to which the BlackBond is attached T1 Parameters T1 interface settings are configured by first selecting the appropriate serial interface INTERFACE S 1 S2 T1 interface commands are configured by first selecting INTERFACE S1 these ports are marked on the BlackBond as Tel1 Tel2 Tel3 Tel4 INT S1 DSU CSU
10. routing tables are kept current as changes are made on the internet Hop A hop is a unit count between networks on the internet A hop signifies one router away Node Device on the network TCP IP Networking Terms FTP File Transfer Protocol gives users the ability to transfer files between IP hosts It uses TCP to provide connection initiation and reliable data transfer A5 Glossary Engage Communication Ss BlackBond Link Encryptor User s Guide Host A computer with one or more uses that can act as an endpoint of communication if it has TCP IP ICMP Internet Control Message Protocol provides a means for intermediate gateways and hosts to commu nicate There are several types of ICMP messages and they are used for several purposes including IP flow control routing table correction and host availability IP Internet Protocol which routes the data IP Datagram The basic unit of the information passed across and IP Internet It contains address information and data PING Packet InterNet Groper is a program which uses ICMP echo request message to check if the speci fies IP address is accessible from the current host Port A Destination point used by transport level protocols to distinguish among multiple destinations within a given host computer SubNet Address An extension of the IP addressing scheme which enables an IP site to use a single IP address for multiple physical networks SubNetting is applicable
11. the BlackBond usually from the same network as the BlackBond itself Proceed through the following symptoms if you are unable to communicate with the local BlackBond using Telnet Ping etc IP Addressing should be double checked Ethernet General Cause Network Cabling is faulty Solution Verify cabling is good by swapping BlackBond cabling with a known good connection Check the status LED s on the 10 100BaseT switch to confirm a good connection If necessary cre ate a stand alone LAN with just the workstation and the BlackBond High Ethernet Error Count Cause Bad cabling or building wiring Solution Check all cabling Swap to known good port on 10 100BaseT hub to troubleshoot testing with large Ping Packets to ascertain quality of Ethernet Connection To eliminate issues with build ing wiring connect the BlackBond with a known good Ethernet cable in the same room as the Ether net hub Can t Communicate Telnet with TCP IP 36 Cause IP address is not set properly on the BlackBond Solution The Console Port which requires an RJ45 to DB9 adapter provides direct access to the configuration of the BlackBond and does not need an assigned IP address Note the RJ45 Cable that connects to the Console Port must have 8 connections pinned 1 to 1 Typical Ethernet cables are only 4 wires The Console port utilizes the Command Line interface detailed in Chapter 4 Com mand Line Interface and in the Appendices Interface T1 s I
12. to store and replay an entire configuration Using a cut and paste operation configurations may be edited off line stored and used later to con figure the IP Tube unit System Level or General Commands CONFIG Enter the configuration mode with the command CONFIG at which point the following commands may be used SAVE Save the changes and exit Configuration mode END SAVE Exit Configuration mode The optional SAVE instructs the IP Tube to save configuration changes RESTORE Restores the current P Tube configuration ignoring any changes which have been made during the current Telnet CONFIG session PASSWD Allows setting or modifying the login password The IP Tube ships with no password set Upon enter ing the PASSWD command the user is prompted to enter and confirm the new password BYE QUIT LOGOUT Any of these commands will terminate the Telnet session If you have unsaved configuration chang es you will be prompted to save or discard the new configuration RESET Resets the IP Tube HELP HELP ALL CONFIG SHOW Provides Help information on a selected list of topics Typing HELP with no argument provides the Help summary screen which is the top level list of commands CLEAR LAN1 LAN2 S1 S2 All Clears the port statistics on the selected port Ethernet LAN Port 1 etc For the IP Tube GI1 GE1 use the command CLEAR LAN1 LAN2 S1 S2 S3 S4 All 23 Chapter 4 Command Line I
13. utilize all channels When Fractional is selected additional options are presented For Fractional T1 with contiguous channels NN is the first T1 channel in use 1 24 and XX is the number of channels to be used In the case that a 384 Kbps fractional T1 uses channels 1 through 6 Start Channel 1 and Total Channels 6 where NN defines the Start Channel XX is the total number of channels T1 FRAC 1 6 Alternatively for channels in use that are not contiguous NN and MM are single T1 channels in use and Y Z are a range of T1 channels in use Single channels and ranges are separated by commas and can be combined on a command line For example an ISDN PRI link uses channel 24 for D Channel signaling and 5 20 for voice circuits T1 FRAC 5 20 24 T1 E1 Transmit Clocking 33 CLOCKMASTER TEL1 TEL2 NETWORK INTERNAL The command CLOCKMASTER determines the source interface TEL1 or TEL2 from which clocking is derived and whether the clock is from that Interfaces NETWORK or INTERNAL Oscillator CLOCKMASTER is used on both units to select the source port of the clocking For the first unit to aquire it s clocking from the TEL2 the WAN Interface interface s incoming T1 E1 data it should be set with the commands CLOCKMASTER TEL2 NETWORK This determines the source of Transmit Clock When set to NETWORK the DSU CSU derives its transmit timing from the received data on TEL2 and is therefore synchronized with the telco the phone
14. 1 frames are sent out TEL2 encrypted When AES is OFF TEL1 passes plain text through to TEL2 AES OFF Turns encryption OFF Warning When AES is OFF TEL1 passes plain text through to TEL2 This mode should only be used during debug to assess whether the T1 E1 Circuit is operating without encryption enabled REKEY ON Turns Rekeying ON REKEY OFF Turns Rekeying OFF REKEY PERIOD NN Days Hours Minutes Sets the cryptoperiod for the Rekey function The cryptoperiod can be set to maximum of 45 days NN is the number Days Hours or Minutes of the cryptoperiod NN defaults to a unit of Minutes if Days or Hours are not specified Note When Rekeying occurs T1 E1 bit Errors will occur 30 Chapter 4 Command Line Interface Engage Communication BlackBond Link Encryptor User s Guide CLOCKMASTER TEL1 TEL2 NETWORK INTERNAL The command CLOCKMASTER determines the source interface TEL1 or TEL2 from which clocking is derived and whether the clock is from that Interfaces NETWORK or INTERNAL Oscillator CLOCKMASTER is used on both units to select the source port of the clocking For the BlackBond to aquire it s clocking from the TEL2 the WAN Interface interface s incoming T1 E1 data it should be set with the commands CLOCKMASTER TEL2 NETWORK Note Refer to Chapter 5 for a more indepth CLOCKMASTER explanation CHANNELS FULL FRACTIONAL NN XX NN Y Z LMM Y Z Indicates if T1 E1 interface usage is all chan
15. ClockMaster TEL1 Network Channels Full Interface S1 Type El El Data Normal El Framing CRC4 El Coding HDB3 E1 TxUnderrunAIS Off Interface S2 Type El El Data Normal El Framing CRC4 El Coding HDB3 E1 TxUnderrunAIS Off Interface S3 Type El El Data Normal El Framing CRC4 El Coding HDB3 E1 TxUnderrunAIS Off 13 Host Name BlackBond Slave Host Contact No contact specified Host Location No location specified TPS On Telnet On UserTimeout 0 SNMP Off SNMP Traps Off Interface LAN 1 AutoNeg On IP Address 192 168 1 50 24 IP Default router 0 0 0 0 Port On BroadcastRcv On Security AES On Rekey On Rekey Mode Slave Rekey Period 1 Day ClockMaster TEL2 Network Channels Full Interface S1 Type El El Data Normal El Framing CRC4 El Coding HDB3 E1 TxUnderrunAIS Off Interface S2 Type El El Data Normal El Framing CRC4 El Coding HDB3 E1 TxUnderrunAIS Off Interface S3 Type El El Data Normal El Framing CRC4 El Coding HDB3 E1 TxUnderrunAIS Off Chapter 2 Installation QuickStart Engage Communication BlackBond Link Encryptor User s Guide 14 Chapter 2 Installation QuickStart Chapter 3 Installation of the BlackBond This chapter provides details on the physical connections required for the installation of Engage BlackBond equipment Also covered is the initial communication with the BlackBond References are made to the Configuration and Operation of the Bla
16. NMP Off SNMP Traps Off Interface LAN 1 AutoNeg On IP Address 192 168 1 50 24 IP Default router 0 0 0 0 Port On BroadcastRcev On Security AES On Rekey On Rekey Mode Slave Rekey Period 1 Day ClockMaster TEL2 Network Channels Full Interface S1 Type T1 T1 Data Normal T1 Framing ESF T1 Coding B8ZS T1 TxUnderrunAIS Off Interface S2 Type TI T1 Data Normal T1 Framing ESF T1 Coding B8ZS T1 TxUnderrunAIS Off Interface S3 Type TI T1 Data Normal T1 Framing ESF T1 Coding B8ZS T1 TxUnderrunAIS Off Chapter 2 Installation QuickStart Engage Communication BlackBond Link Encryptor User s Guide Example BlackBond E1 Standard BlackBonds are connected to external E1 WAN circuit that is the E1 clock source Host Name BlackBond Master Host Contact No contact specified Host Location No location specified TPS Off Telnet On UserTimeout 0 SNMP Off SNMP Traps Off Interface LAN 1 AutoNeg On IP Address 192 168 1 50 24 IP Default router 0 0 0 0 Port On BroadcastRcv On Security AES On Rekey On Rekey Mode Master Rekey Period 1 Day ClockMaster TEL2 Network Channels Full Interface S1 Type El El Data Normal El Framing CRC4 El Coding HDB3 E1 TxUnderrunAIS Off Interface S2 Type El El Data Normal El Framing CRC4 El Coding HDB3 E1 TxUnderrunAIS Off Interface S3 Type El El Data Normal El Framing CRC4 El Coding HDB3 E1 TxUnderrunAIS Off 11 H
17. P Address must be in the subnet of the computer that is attempting to access it locally Cause Workstation not on the same subnet as the BlackBond Solution During an initial configuration of a BlackBond communication should come from within the same net subnet With no default router the BlackBond will not be able to reply to communication off its own subnet Cause IP stack on the workstation not configured Chapter 6 Troubleshooting Engage Communication BlackBond Link Encryptor User s Guide Solution Ensure that other devices on the same LAN can be pinged or otherwise seen Can t communicate to the BlackBond Console Port Cause Baud Rate Stop Bits etc set wrong on communication application Solution Ensure the communication software is configured for a fixed asynchronous data rate of 9600 bps 1 stop bit no parity 8 bit fixed and that the Flow control is set to none Cause Transmit and Receive Data swapped Solution The console port RJ45 to DBY adapter is configured as a DCE data communication equip ment port Note the RJ45 Cable that connects to the Console Port must have 8 connections pinned 1 to 1 Typical Ethernet cables are only 4 wires The RJ45 to DB9 adapter has a null modem func tion for connections to other DCE devices such as a modem BlackBond Not Making a WAN Connection Cause BlackBonds not be passing good data or have AES light OFF Solution LNK LED must be ON for both TEL1 and TEL2
18. Parameters The BlackBond T1 serial interface number is configured for T1 operation The following T1 param eters must match the configuration of the DS1 T1 interface to which it is connected Interface S1 Type T1 T1 Data Normal Invert T1 LBO CSU 0dB 7 5 15 22 5 T1 Framing ESF D4 T1 Coding B8ZS AMI E1 Parameters 34 E1 interface settings are configured by first selecting the appropriate serial interface INTERFACE S1 S2 DSU CSU Parameters The following E1 parameters must match the configuration of the E1 interface to which it is connect ed Interface S1 Type E1 E1 Data Normal Invert E1 Framing CRC4 E1 Coding HDB3 AMI Chapter 5 BlackBond T1 E1 Configuration and Operation 35 Chapter 5 BlackBond T1 E1 Configuration and Operation Engage Communication BlackBond Link Encryptor User s Guide Chapter 6 Troubleshooting Communication and Network systems are subject to problems from a variety of sources Fortunately an organized troubleshooting approach usually leads to the area of the problem in short order It is essential to distinguish between problems caused by the LAN network system the WAN equipment communication equipment the T1 E1 Equipment and the BlackBond configuration This troubleshooting chapter is structured with symptoms in the order the user might encounter them Unable to Communicate with the BlackBond Installations first require communication with
19. and for TPS OPTION TEL3 Make sure that the Framing of the T1 or E1 Equipment matches that of the BlackBond Interface For Example T1 Framing of ESF of SF D4 and E1 Framing of CRC4 Solution The T1 E1 connection between the BlackBonds is not functional Try using an T1 E1 cross over on the bench between the BlackBonds if possible Solution AES may not be configured ON both BlackBonds Solution the keys entered using enterkey might not be identical for both units Solution the rekey on off or rekey period parameter may not be identical for both units Solution the rekey mode isn t configured as master for one unit and slave for the other Solution the T1 E1s have errors in show stat possibly clocking config error if the local CPE is internally clocking then the BlackBond it is connected to should have clock master tel1 network and the remote BlackBond should have clockmaster tel2 network if the neither CPE is internally clocking and there is no clocking generated in the line between the Blackbonds then the local Blackbond should have clockmaster tel1 internal and the remote BlackBond should have clockmaster tel2 network if the neither CPE is internally clocking and there is clocking generated in the line between the Blackbonds then both Blackbonds should have clockmaster tel2 network also possible errant t1 or e1 data setting this parameter must match between any two T1 E1 ports being exter
20. ault Router Normal selection of a defalt router is only necessary when the units reside on different network 7 Chapter 2 Installation QuickStart Engage Communication Example BlackBond T1 Standard BlackBond Link Encryptor User s Guide BlackBonds are connected to external T1 WAN circuit that is the T1 clock source Host Name BlackBond Master Host Contact No contact specified Host Location No location specified Telnet On UserTimeout 0 SNMP Off SNMP Traps Off Interface LAN 1 AutoNeg On IP Address 192 168 1 50 24 IP Default router 0 0 0 0 Port On BroadcastRcv On Security AES On Rekey On Rekey Mode Master Rekey Period 1 Day ClockMaster TEL2 Network Channels Full Interface S1 Type T1 T1 Data Normal T1 Framing ESF T1 Coding B8ZS T1 TxUnderrunAIS Off Interface S2 Type TI T1 Data Normal T1 Framing ESF T1 Coding B8ZS T1 TxUnderrunAIS Off Interface S3 Type T1 T1 Data Normal T1 Framing ESF T1 Coding B8ZS T1 TxUnderrunAIS Off Host Name BlackBond Slave Host Contact No contact specified Host Location No location specified Telnet On UserTimeout 0 SNMP Off SNMP Traps Off Interface LAN 1 AutoNeg On IP Address 192 168 1 50 24 IP Default router 0 0 0 0 Port On BroadcastRcv On Security AES On Rekey On Rekey Mode Slave Rekey Period 1 Day ClockMaster TEL2 Network Channels Full Interface S1 Type T1 T1 Data Normal T1 Framing ESF
21. cation service s transmission reception medium and includes T1 Voice Data Multiplexors 64 56 Kilobit DSU CSU s and Fiber Optic Modems The DCE provides the transmit and receive data pathways along with their synchronous clocking signals that are used by the Engage Router s DTE interface for full duplex communication between the remotely intercon nected networks Data Terminal Equipment DTE This equipment such as an Engage Router attaches to the terminal side of Data Communication Equipment Data Carrier Detect DCD A signal that indicates to the DTE that the DCE is receiving a signal from a remote DCE Data Terminal Ready DTR Prepares the DCE to be connected to the phone line then the connection can be established by dial ing Enables the DCE to answer an incoming call on a switched line 47 Glossary
22. cess plus examples to get the experienced user up and running in a minimum of time Chapter 3 nstallation of the Black Bond gives a detailed step by step of the installation and configu ration of the BlackBond unit It covers the physical environment and connections required to install the units then steps the administrator through the configuration process of the console port LAN con nection and the T1 E1 interfaces Chapter 4 Command Line Interface provides a command by command description of the upper level interface as well as the interfaces to the various ports Chapter 5 BlackBond T1 E1 Configuration and Operation discusses the initial configuration and ongoing operation of the BlackBond T1 and E1 models Also included is a brief discussion of SNMP support Chapter 6 Troubleshooting reviews some of the common issues that may occur during installation and normal operation of the units and provides descriptions of causes and solutions to these issues Appendices BlackBond T1 E1 specifications connector pinouts and crossover wiring details and includes diagrams of the units Glossary TCP IP terminology Networking and Communications definitions Intended Audience This manual is intended for IT administrators The technical content is written for readers who have basic computer telecommunication and networking experience It is important that any administrator responsible for the installation and operation of Engage B
23. ckBond as well as to the Com mand Line Interface These topics are covered in detail in later chapters The use of the Engage BlackBond system to provide data encryption requires one BlackBond Unit at each end of a T1 E1 connection A standard BlackBond package includes BlackBond unit with installed interfaces T1 or E1 Console port adapter and cable RJ45 to DB9 connector Two cross over T1 E1 cables Power Converter universal accommodates either 110 or 220 AC with 100 240 at 47 63 hz outputing 12 volts to the unit Alternate 48 upgrade also available Documentation compact disk with BlackBond Link Encryptor User s Guide BlackBond Installation Steps The process of installing a BlackBond T1 E1 involves the following steps 15 Planning for BlackBond interconnect Installing the BlackBond hardware Configuring System and Ethernet parameters Configuring the BlackBond interface parameters Making Ethernet and T1 E1 cabling connections Verifying the BlackBond connection Chapter 3 Installation Engage Communication CBlackBond Link Encryptor User s Guide Installing the Hardware Locating the BlackBond Unit Site consideration is important for proper operation of the BlackBond The user should install the unit in an environment providing e A well ventilated indoor location e Access within six feet of a power outlet e Two feet additional clearance around the unit to permit easy cabling connection e As an option
24. d Off also IP ADDRESS address mask The interface IP address and subnet mask are required for connection to the network configuration with telnet or connectivity tests with ping The subnet mask can be entered in long or short form Examples IP ADDRESS 192 168 1 1 255 255 255 0 IP ADDRESS 192 168 1 1 24 IP DEFAULT ROUTER address Configures the IP address of the default router or gateway for this Ethernet interface This must be an IP address on the same network as the IP Tube Ethernet interface This default router takes pre cedence over the system s default router NOTE If DHCP is ON for this LAN interface the Default Router Gateway is discovered 29 Chapter 4 Command Line Interface Engage Communication BlackBond Link Encryptor User s Guide AES Commands and Key Generation GENKEY A random 256 bit key is generated with the GENKEY command This key is to be used for the en cryption function on the BlackDoors At the system level enter this command and it will create a key to input into both units The Key must be identical for decryption to work ENTERKEY N XXXXXX the actual key is 64 hex characters On both units issue the ENTERKEY command and provide the key generated by the output of the master s GENKEY command The output of the GENKEY command can be copied into an editor an prefaced with ENTERKEY command and pasted onto the CLI when in configuration mode AES ON OFF AES ON Turns encryption ON TEL1 T1 E
25. d SNMPv1 Traps SHOW Commands SHOW INTERFACE LAN 1 LAN2 S1 S2 INFO STATISTICS For the IP Tube GT1 GE1 use the command SHOW INTERFACE LAN 1 S1 S2 S3 S4 INFO STATISTICS Provides details on any LAN or serial interface If no interface is specified either the current interface per the Interface command will be used or all interfaces will be shown INFO Details the port type protocol type port state buffer count etc STATISTICS Lists the packets received and transmitted errors etc SHOW ROUTER Provides general configuration and status information including the Ethernet hardware addresses and the firmware version SHOW IP STATISTICS Provides more detailed statistics on IP packets only SHOW CONFIG ALL Provides a list of all configuration parameters No argument is the same as ALL This list provides the basis for storing an IP Tube configuration into a local text file The full configuration can be edited in a text editor for simple cut and paste configuration of the unit SHOW CONFIG INTERFACE LAN1 LAN2 S1 S2 S3 4 If no interface is specified either the current interface per the interface command will be used or all 29 Chapter 4 Command Line Interface Engage Communication BlackBond Link Encryptor User s Guide interfaces will be shown SHOW CONFIG IP ALL Details the IP configuration No argument is the same as ALL which provides configuration items wh
26. dard RJ45 cable 8 straight 1 to 1 Interface S1 Configuration Interface S1 must have its Type set to T1 or E1 BlackBond T1 Interface Framing Port 1 Green indicates reception of T1 E1 frames from the T1 E1 Equipment attached to Port 1 s T1 E1 interface that matches the T1 E1 framing protocol configuration of BlackBond T1 ESF or D4 E1 CRC4 or FAS and E1 Coding HDB3 or AMI Port 1 will turn green independent of the configu ration of the network parameters and whether the number of DSOs matches Local BlackBond Port 1 LED Green but T1 E1 Circuit Extension not working 38 BlackBond T1 E1OverlIP Interface Loop back A method to locally loop back the T1 E1OverlP interface back to itself in order to test the configura tion of the T1 E1 Equipment and Interface S1 and the cabling Port 1 Green Indicator does not verify Transmit signal connection from the BlackBond to the T1 E1 Equipment Line is to set the unit s destination IP Address to be the same as the IP Address of the Ethernet Interface During this test to insure that interference is not occurring from a BlackBond that is pointed to the BlackBond placed in loop back make sure that all known BlackBond units that could be streaming T1 E1OverlIP packets to it are turned off The T1 E1 equipment should then detect that it is receiving what it is sending A T1 E1 test set could be used to stream a test pattern into Interface S1 for testing Basic T1 E1 sets do not have fractional T1
27. ds is the HELP command providing information on the entire com mand set The Help command can be used in or out of the configuration modes Configuration Modes For the Config and Config Interface commands Engage employs a model approach The user enters the Config mode with the CONFIG command makes changes then SAVEs those changes END enables you to exit the config mode The Config Interface mode within the Config mode is used to set parameters for a specified inter face Once in the Configuration mode the user enters the INTERFACE command specifying the port that is to be configured All subsequent commands apply to the specified interface Example name INTERFACE S1 The command prompt indicates the mode of operation name the single indicates standard Telnet mode name indicates the IP Tube is in the Config mode name LAN1 IP Tube is in Config Interface mode for LAN Port 1 To move up one level from Interface Config mode to Config mode enter the INTERFACE command with no argument To change between interfaces when in Interface Config mode specify the new interface For example name s1 INTERFACE LAN 22 Chapter 4 Command Line Interface Engage Communication BlackBond Link Encryptor User s Guide Syntax for Command Parameters one of the parameters in set is required one of the parameters in set is allowed optional Show Config All The SHOW CONFIG ALL command provides the means
28. e familiar to you General Networking Terms Network A network is a collection of computers server devices and communication devices connected to gether and capable of communication with one another through a transmission medium Internet An internet is any grouping of two or more networks connected by one or more internet routers Network Services Network services are the capabilities that the network system delivers to users such as print servers file servers and electronic mail Addresses Transmitting information in a network system is made possible by an addressing scheme that identi fies the sender and destination of the transmission using network and node addresses Data is trans mitted to and from these addresses in the form of packets Routing Table A routing table is maintained in each router This table lists all networks and routers in the internet and enables routers to determine the most efficient route for each packet The routing table serves as a logical map of the internet specifying the address of the next router in the path to a given desti nation network and the distance in hops The router uses the routing table to determine where and whether to forward a packet Each router periodically broadcasts its routing table to other routers on each of its directly connected networks enabling them to compare and update their own tables with the most recent record of con nected networks and routes In this way
29. e Coding and Clock Source are configurable using the Com mand Line Interface 18 Chapter 3 Installation Engage Communication BlackBond Link Encryptor User s Guide Status LED s Front panel LED s provide Serial Interface Ethernet LAN1 and Console status and an AES on or off indicator The ENA indicators designate that a port is ENAbled Power The Power LED is green when operational It is located at the front left corner of the unit LAN1 Ethernet Interface LEDs The BlackBond provides specific information with TD and RD indicators providing status on packet transmission and receipt respectively on the Ethernet interface When transmitting the LAN1 TD will show a steady GREEN e When receiving the LAN1 RD will show a steady GREEN T1 Interface LEDs The BlackBond T1 E1 provides specific information with TEL1 S1 TD and TEL1 S1 RD indicators providing status on valid framing from the T1 E1 device or line to which the BlackBond is connected e When transmitting the TEL1 TD will show a blinking or steady GREEN e When receiving the TEL1 RD will show a blinking or steady GREEN If the BlackBond is unable to receive valid frames from the connected equipment via the T1 E1 line the RD will be off ENA indicates the port is ENAbled e When connecting to the T1 E1 links ST will show no color for a positive link unless a loopback has been configured e For correct framing status between the BlackBond T1 and the T1 equipmen
30. g 36 Unable to Communicate with the BlackBond36 Ethernet General 36 High Ethernet Error Count 36 Can t Communicate Telnet with TCP IP 36 Can t communicate to the BlackBond Console Port 37 BlackBond Not Making a WAN Connection 37 T1 E1 Circuit Extension to Remote not Functioning 38 Local BlackBond Port 1 LED does not go green 38 Local BlackBond Port 1 LED Green but T1 E1 Circuit Extension not working 38 TCP IP Connection 39 Appendix A BlackBond T1 E1 Specifications 40 T1 Specifications 40 Quality of Service Support 40 TFTP Online Upgrade Capable FLASH ROM s 40 Ethernet Port 40 LAN Protocol 40 BlackBond Protocols 40 Serial Interfaces 40 Management 41 Power Supply 41 Physical 41 Glossary 45 Terms and Concepts 45 General Networking Terms 45 TCP IP Networking Terms 45 Communication Link Definitions 46 Engage Communication Ss BlackBond Link Encryptor User s Guide Chapter 1 Introduction The BlackBond User s Guide provides the information users require to install and operate the BlackBond family of products developed and manufactured by Engage Communication Inc About this Guide Organization Chapter 1 ntroduction provides an overview of the BlackBond Link Encryptor User s Guide as well as feature descriptions for the T1 E1 models which make up the BlackBond family Chapter 2 Installation QuickStart provides a concise description of the installation and configuration pro
31. g harm to the telephone network the telecommunications service provider may request that you disconnect the equipment until the problem is resolved Engage Communication Service Center Phone U S 1 831 688 1021 Fax 1 831 688 1421 Email support engageinc com Web www engageinc com Contents Chapter 1 Introduction 1 About this Guide 1 Organization 1 Intended Audience 1 BlackBond AES Link Encryption Family 2 BlackBond T1 E1 Protection Switch OPTION TPS 2 BlackBond T1 E1 Link Protector Switch OPTION LPT 2 Security 2 BlackBond Physical Interfaces 3 Chapter 2 Installation QuickStart 4 Communication with the BlackBond Link Encryptor 4 Console Port 4 Telnet 4 Editing and Pasting Configurations 4 BlackBond Cabling 5 BlackBond Configuration Parameters 5 BlackBond Securty Parameters 5 Interface Specific T1 E1 Parameters 6 BlackBond Clocking T BlackBond System Parameters 7 Example BlackBond T1 Standard BlackBonds are connected to external T1 WAN circuit that is the T1 clock source 8 Example BlackBond T1 FRACTIONAL BlackBonds are connected to external T1 WAN circuit that is the T1 clock source 9 Example BlackBond T1 TPS OPTION T1 WAN Protection Switch BlackBond Master s Tel is con nected to external T1 circuit that is the T1 clock source 10 Example BlackBond E1 TPS OPTION E1 WAN Protection Switch BlackBond Master s Tel1 is con nected to external E1 circuit that is the E1 c
32. he unit with DIP Switch 1 ON forces the BlackBond to return to factory default settings Factory settings include operation from Base Flash and deleting any download up grades Ensure Switch 1 is returned to the OFF position after clearing an upgrade so future upgrades can be performed successfully Also for the BlackBond T1 E1 models Switch 1 ON allows a login without a password This is useful when a password is forgotten careful not to power off or any upgrades will be lost Switch 1 OFF retains the previously configured password Switch 2 This switch must remain OFF for the unit to be functional Switch 3 Switch 3 is used for testing during manufacturing The switch must be set to OFF for normal operation Switch 4 DIP Switch 4 is used during the manufacture and quality assurance process It must be in the OFF position for normal use BlackBond Cabling The BlackBond uses standard 10 100BaseT Ethernet cabling to connect to an Ethernet switch or hub The cabling that is used to connect the BlackBond T1 Port T1 1 or E1 Port E1 1 to the T1 E1 interface to be extended through the BlackBond depends upon whether it is connecting to equipment or directly to a T1 E1 line In the case of a connection to the T1 E1 interface of T1 E1 Data Terminal Equipment a cross over cable is required Refer to the Appendices for the details of the wiring of this cable Connections to T1 lines is done with a standard T1 cable An E1 connection utilizes
33. hould not occur with Procotol IPTube Receive Overrun Overrun of internal FIFO used in transfer of serial data to memory or a frame was received and dis card due to lack of buffers or a large frame was received Receive Framing Set when a frame containing a number of bits not exactly divisible by eight is received Receive Misc Carrier Dectect Loss during buffer reception Packets Transmitted Number of serial packets transmitted Transmit CSL CTS was lost during frame transmission Transmit UN Underrun the serial controller encountered a transmitter underrun while sending a buffer or a trans mit operation failed due to lack of buffers Transmit Misc Unspecified transmit error not associated with a buffer Packets Out Of Sequence A packet arrived out of sequence This indicates either a missing packet or a packet received out of order If Tube SequenceRecovery is On the packet is placed in the proper order and is not neces sarily a data error If Tube SequenceRecovery is Off this would be an error in the data stream Packet Sequence Disruption x y Packet Sequence Disruption displays the sequence number of packets received adjacent to se quence number gaps For example if the display is 5 7 that means sequence number 6 was miss ing Or 5 56 would indicate 50 packets were missing Note the sequence number is modulo 255 so a display of 255 1 would mean only the packet with sequence number 0 is m
34. ich don t pertain to a specific port i e default router gateway etc SHOW CONFIG ROUTER Lists IP Tube Hostname IP Address etc LAN Interface Statistics Packets Received The number of LAN packets received Receive CRC The packet had a CRC error Receive Overrun Overrun of internal FIFO used in transfer of LAN data to memory or a frame was received and dis card due to lack of buffers or a large frame was received Receive Framing A nonoctect aligned frame was received Receive Misc A short frame was received or a general error indicating an unexpected result in an buffer descriptor or a buffer that was not a complete frame was recieved on the Ethernet channel Packets Transmitted Number of LAN packets transmitted Transmit CSL Carrier sense lost during frame transmission Transmit UN Underrun the Ethernet controller encountered a transmitter underrun while sending a buffer Transmit RL Retransmission Limit The transitter failed attempts to successfully send a message due to repeated collisions statistic not set on IPTube Transmit LC Late collision A collision occured after 64 bytes are sent statistic not set on IPTube Transmit Misc Unspecified transmit error not associated with a buffer 26 Chapter 4 Command Line Interface Engage Communication BlackBond Link Encryptor User s Guide Serial Interface Statistics Packets Received Number serial of packetes received Receive CRC CRC error S
35. ion with Crossover Pinouts TiftracT1 DSUfCSU Pim numbering RxRing RaTip TxRing TxTip Cl fe hI For T1 Crossover allowing connection directly between two T1 fracT1 OSUSC SU devices wire TxTip Pin5S to Pin2 RxTip TxRing Pind to Pini RxRing RxRing Pind to Pind TxRing RxTip Pin to PinS TxTip E1 RJ45 to db15 Cable Signal RJ45 db15 Male TxD Tip 5 1 RxD Tip 2 3 TxD Ring 4 9 RxD Ring 1 11 Frame Ground 7 2 42 Appendices Engage Communication BlackBond Link Encryptor User s Guide 10 100BaseT Port Specification w Crossover cable pinout l0BaseT Plug pin numbering Pind TxD Pin2 TxD Pins RxD Pin RxD For 10BaseT Crossover allowing connection directly between two 10BaseT devices wire TD Pind to Pin3 RD TD Pin to Pin RD RD Pin3 to Pini TD RD Pin6 to Pin TD 43 Appendices Engage Communication 44 BlackBond Link Encryptor User s Guide Console Port Information RJ45 Console Port Pinout RJ45 pin bo BR OF DW W Signal Name TxData RxData RTS CTS Gnd DTR RJ45 db9F Null Modem Adapter RJ45 pin NW BRD Ww db9pin Nn WO W N Appendices Engage Communication SC BlackBornd Link Encryptor User s Guide Glossary Terms and Concepts Before using the Engage BlackBond Link Encryptor you should be familiar with the terms and con cepts that describe TCP IP If you are experienced with internet routers these terms may already b
36. ion mode with the command config Paste the edited text comments and all to the BlackBond then issue the command save The BlackBond will reset and come up with the new configuration To save a BlackBond configuration in a text file for later use issue the command show configura tion all and copy the listing to a file Engage Communication BlackBond Link Encryptor User s Guide BlackBond Cabling The BlackBond uses standard 10 100BaseT cabling to connect to an Ethernet switch or hub A crossover 10 100BaseT cable can be used for direct connection to a Personal Computer The cabling used to connect the BlackBond T1 E1 Port to the T1 E1 interface depends upon whether it is connecting to T1 E1 equipment PBX Phone System Multiplexor or directly to a T1 E1 line In the case of a connection to the T1 E1 interface of Telco equipment a crossover cable is required The BlackBond T1 E1 is shipped with a T1 E1 Crossover Cable that uses yellow cabling Refer to the Appendices for the details of the wiring of this cable Connections to T1 E1 lines are made with a standard straight through T1 E1 cable BlackBond Configuration Parameters The setup of the BlackBond involves configuration of the e BlackBond Security Parameters e Interface Specific T1 E1 parameters e BlackBond Clocking e BlackBond System Parameters BlackBond Securty Parameters AES ON In configuration mode this command turns encryption ON AES OFF In configurati
37. ion with the BlackBond unit is made through the Console port utilizing the Com mand Line Interface CLI detailed in Chapter 4 Command Line Interface Communication to the Console port should be set as 9600 baud 1 stop bit no parity 8 bit fixed and flow control none The Console port on the BlackBond is an RJ45 jack It is configured as a DTE port An RJ45 DB9 adapter is provided with the BlackBond which in addition to providing a physical interface performs the null modem operation permitting direct connection to other DTE equipment such as COM con nections on a PC Once a serial connection between a workstation and the BlackBond Console port is established and a carriage return lt CR gt is entered a Login prompt will appear The default login is root No password is needed for the initial login lf an IP address has been assigned and a connection established to the BlackBond Ethernet LAN port the user can telnet into the unit from anywhere on the network and continue configuration Editing and Pasting Configurations Users of either telnet or the console have the option of editing standard BlackBond configurations in a text editor and pasting that configuration to the BlackBond Each example in this chapter includes a configuration file found on the shipping disk Edit the desired configuration listing using a text editor Connect to the BlackBond through Telnet or the Console port then enter the interface configurat
38. issing Packets Arriving Too Late The packet arrived with a sequence number that had already been transmitted on the serial port The IP network delayed the packet too late for transmission This is a data error Packets Arriving Late are counted only when Tube SequenceRecovery is On or Protocol ADPIPTube is selected Packets Not Arriving A packet for a given sequence number never arrived This is a data error Packets Not Arriving are counted only when Tube SequenceRecovery is On or Protocol ADPIPTube is selected Gaps in sequence due to Packets Arriving Late or Packets Not Arriving are filled with data from the next arriving packet Packets Rcvd w Bad Source IP Addr A packet received with the correct UDP port and destination IP address did not have a source ad dress matching the Tube Destination address This packet is dropped 2 Chapter 4 Command Line Interface Engage Communication BlackBond Link Encryptor User s Guide Packets Rcvd w Bad UDP Port A UDP packet received with the correct destination and source IP address did not have a UDP source and destination port number matching the Tube UDPPort number This packet is dropped Transmit Drain Drops This is a serial transmit queue overflow The number of packets in the serial transmit queue exceeds the setting of Tube Buffers by 3 packets and is dropped Transmit Buffer Queue Depth The number of packets in the serial transmit queue Config Interface Commands Configuration
39. lackBond for use with standard 9 pin COM ports The RJ45 console port is configured as a DTE data terminal equipment port This allows direct con nection to a DCE data communication equipment device such as a modem For connection to other DTE such as a terminal the RJ45 to DB9 adapter which is provided with the BlackBond serves the null modem function permitting direct connection to the COM interface of most PCs Logging in to the BlackBond A Telnet session is opened by configuring the IP address of the BlackBond Upon opening a CLI command line interface session via Telnet or the Console port the login prompt requires entry of a login ID The default login ID root The BlackBond is shipped with no password set Passwords are set or modified with the passwd command detailed below 21 Chapter 4 Command Line Interface Engage Communication BlackBond Link Encryptor User s Guide Overview of Commands The Engage CLI supports shorthand character entry At most 3 characters are required for the pars ing of the commands For example show configuration can be entered as sh con The CLI is not case senstive Description of the commands uses both upper and lower case for syntax definitions and examples A full description of the command line interface follows Categories The command set can be divided into four categories General Show e Config e Config Interface Online Help Included in the General comman
40. lackBond products be familiar with IP networking and data communication concepts such as net work addressing and synchronous serial interfaces These terms are central to an understanding of BlackBond functionality and are covered in the Glossary section 1 Chapter 1 Introduction Engage Communication Ss B lackBond Link Encryptor User s Guide BlackBond AES Link Encryption Family BlackBond T1 E1 models encrypt data on full or fractional T1 or E1 circuits The following BlackBond models are equipped with built in data encryption BlackBond T1 AES Link Encryptor BlackBond E1 AES Link Encryptor BlackBond T1 E1 Protection Switch OPTION TPS The T1 E1 Link Protector provides an automatic backup for E1 circuits with a second E1 WAN inter face The switch over criteria is configured Switching Criteria 1 A loss of sync on TEL2 2 Alarm Indication T1 a yellow alarm in which the ESF DL bits show a repeating pattern E1 remote alarm indicated in framing byte and sync on TEL3 triggers a crossover 3 Sync and absence of any alarm on TEL2 trigger recovery operation over TEL2 BlackBond T1 E1 Link Protector Switch OPTION LPT The T1 E1 Link Protector provides a Secure automatic backup for T1 E1 circuits with E1 Over IP Eth ernet connecting via Wireless Ethernet Gigabit Ethernet IP Satellite Services xDSL Security AES Encryption The BlackBond utilizes the Advanced Encryption Standard AES with 256 bit keys to secure sensi
41. lave Rekey Period 1 Day ClockMaster TEL2 Network Channels 1 8 Interface S1 Type T1 T1 Data Normal T1 Framing ESF T1 Coding B8ZS T1 TxUnderrunAIS Off Interface S2 Type T1 T1 Data Normal T1 Framing ESF T1 Coding B8ZS T1 TxUnderrunAIS Off Interface S3 Type T1 T1 Data Normal T1 Framing ESF T1 Coding B8ZS T1 TxUnderrunAIS Off Chapter 2 Installation QuickStart Engage Communication BlackBond Link Encryptor User s Guide Example BlackBond T1 TPS OPTION T1 WAN Protection Switch BlackBond Master s Tel1 is connected to external T1 circuit that is the T1 clock source Host Name BlackBond Master Host Contact No contact specified Host Location No location specified TPS On Telnet On UserTimeout 0 SNMP Off SNMP Traps Off Interface LAN 1 AutoNeg On IP Address 192 168 1 50 24 IP Default router 0 0 0 0 Port On BroadcastRcv On Security AES On Rekey On Rekey Mode Master Rekey Period 1 Day ClockMaster TEL1 Network Channels Full Interface S1 Type T1 T1 Data Normal T1 Framing ESF T1 Coding B8ZS T1 TxUnderrunAIS Off Interface S2 Type T1 T1 Data Normal T1 Framing ESF T1 Coding B8ZS T1 TxUnderrunAIS Off Interface S3 Type TI T1 Data Normal T1 Framing ESF T1 Coding B8ZS T1 TxUnderrunAIS Off 10 Host Name BlackBond Slave Host Contact No contact specified Host Location No location specified TPS On Telnet On UserTimeout 0 S
42. ligence strict liability other tort or otherwise shall in no event exceed the repair price of the work to which such cause arises In no event shall Seller be liable for incidental consequential or punitive damages resulting from any such cause Seller may at its sole option either repair or replace defective goods or work and shall have no further obligations to Buyer Return of the defective items to Seller shall be at Buyer s risk and expense C Seller shall not be liable for failure to perform its obligations under the con tract if such failure results directly or indirectly from or is contributed to by any act of God or of Buyer riot fire explosion accident flood sabotage epidemics delays in transportation lack of or inability to obtain raw materials components labor fuel or supplies governmental laws regulations or orders other circumstances beyond Seller s reasonable control whether similar or dissimilar to the foregoing or labor trouble strike lockout or injunction whether or not such labor event is within the reasonable control of Seller onah Nat Copyright 2001 2007 Engage Communication Inc All rights reserved This document may not in part or in entirety be copied photocopied reproduced translated or reduced to any electronic medium or machine readable form without first obtaining the express written consent of Engage Communi cation Restricted rights legend Use duplication or disclosure by the U S
43. lock source 13 Chapter 3 Installation of the BlackBond 15 BlackBond Installation Steps 15 Installing the Hardware 16 Locating the BlackBond Unit 16 Powering the BlackBond 16 Console Port 16 Configuring the Engage BlackBond forthe LAN 17 Ethernet Interface 17 BlackBond Serial Interface Options T1 Interface 17 E1 Interface 17 Status LED s 19 LAN1 Ethernet Interface LEDs 19 T1 Interface LEDs 19 E1 Interface LEDs 19 Internal DIP Switches 20 BlackBond Cabling 20 SNMP Support 20 Chapter 4 Command Line Interface 17 21 Console Communication 21 Overview of Commands 22 Categories 22 Online Help 22 Configuration Modes 22 Syntax for Command Parameters 23 Show Config All 23 System Level or General Commands 23 Upgrade Firmware 24 SNMP Configuration 25 SHOW Commands 25 LAN Interface Statistics 26 Serial Interface Statistics 27 Config Interface Commands28 Local Area Network Interfaces 29 AES Commands and Key Generation 30 Interface Configuration 32 The TYPE parameter should be set to T1 or E1 depending on the equipment to which the BlackBond is attached 32 T1 Interface Configuration 32 E1 Interface Configuration 32 Protection Switch OPTION TPS Commands 32 Chapter 5 T1 E1 Interface Configuration amp Operation 33 T1 E1 Timeslot Configuration Full or Fractional 33 T1 E1 Transmit Clocking 33 T1 Parameters 34 E1 Parameters 34 Chapter 6 Troubleshootin
44. ly send messages until the ESC key is pressed Upgrade Firmware UPGRADE TFTP Server Addr Filename TFTP trivial file transfer protocol provides a means for upgrading IP Tube firmware in a TCP IP environment A TFTP upgrade can be accomplished by aquiring the upgrade file from Engage Com munication Technical Support and placing it on your own local TFTP server Example UPGRADE 157 22 234 129 ML107407 COD Ensure IP connectivity between the IP Tube and the TFTP server by pinging from one to the other Then issue the upgrade command Note An IP Tube which is running an upgrade must go through a reset This may cause a Telnet connection to drop If this does occur simply re establish the Telnet connection 24 Chapter 4 Command Line Interface Engage Communication BlackBond Link Encryptor User s Guide SNMP Configuration SNMP ON OFF Turns ON or OFF receipt and transmission of standard SNMP queries excluding traps Note OFF disables processing and responses to standard SNMP queries excluding traps SNMP COMMUNITYNAME Set or modify IP Tube SNMP community name This string is used for authentication of SNMP Se tRequests and SNMP traps SNMP TRAPS ON OFF Turns ON or OFF generation of SNMPv1 Traps The Destination Address for these traps must be configured to be an SNMP management station capable of decoding SNMPv1 traps SNMP TRAPS ADDRESS address Sets the Destination IP Address to which the IP Tube will sen
45. ment and T1 WANS The interface connects to the T1 interface of T1 based telecommunication equipment such as a PBX or a T1 Multi plexer This connection uses a panel RJ48 jack and accepts 8 pin modular plugs T1 circuits use pins 1 amp 2 for RxData and 4 amp 5 for TxData See Appendices for the T1 interface pinout The T1 interface can be configured to operate at rates from 64Kbps to full T1 at 1 544 Mbps All configuration items including Line Coding Framing and TxData clocking are configurable using the Command Line Interface E1 Interface 17 The internal E1 DSU CSU permits direct connection to the E1 interface of E1 based telecommunica tion equipment such as a PBX or an E1 Multiplexer This connection uses a panel RJ48 jack and ac cepts 8 pin modular plugs E1 circuits use pins 1 amp 2 for RxData and 4 amp 5 for TxData An RJ48 db15 adapter cable is available if the E1 line is terminated in a 15 pin male D connector See Appendices for E1 pinout and cable specification Note The E1 interface is 120 ohm balanced The E1 RJ45 interface is converted to the E1 120 bal anced db15 Male interface via a RJ45 to DB15 male adapter Chapter 3 Installation Engage Communication CBlackBoondl Link Encryptor User s Guide An external 120 ohm to 75 ohm Balun can be ordered to convert the RJ45 120 ohm to 75 Coaxial The E1 interface can be set to run at rates from 64Kbps to full E1 speed of 2 048 Mbps All configuration items including Lin
46. nally connected also possible possibly faulty cabling faulty line quality of service provided between the units or faulty CPEs BF Chapter 6 Troubleshooting Engage Communication BlackBond Link Encryptor User s Guide T1 E1 Circuit Extension to Remote not Functioning The T1 E1 Circuit Extension Over IP is Optional Local BlackBond Port 1 LED does not go green All equipment has been configured and connected and the T1 E1 equipment has been turned up yet the port 1 LED does not turn to green Green indicates reception of T1 E1 frames from the T1 E1 Equipment attached to Port 1 s T1 1 E1 1 interface that matches the T1 E1 framing protocol configu ration of BlackBond T1 ESF or D4 E1 CRC4 or FAS Port 1 will turn green independent of the configuration of the network parameters and whether the number of DSOs matches E1 requires that the line coding matches also E1 HDB3 line coding is recommended Proceed through the following steps in sequence BlackBond Cabling The cabling that is used to connect the BlackBond depends upon whether it is connecting to equip ment or directly to a T1 E1 line In the case of a connection to the T1 E interface of T1 E1 Equipment a cross over cable is required For E1 connections the cross over cable is used between the RJ45 connector on the BlackBond and the RJ45 to DB15 Male adapter Refer to the Appendices for the details of the wiring of this cable Connections to a T1 E1 line is done with a stan
47. nels or Fractional FULL will utilize all channels When Fractional is selected additional options are presented For Fractional T1 with contiguous channels NN is the first T1 channel in use 1 24 and XX is the number of channels to be used In the case that a 384 Kbps fractional T1 uses channels 1 through 6 Start Channel 1 and Total Channels 6 where NN defines the Start Channel XX is the total number of channels T1 FRAC 1 6 Alternatively for channels in use that are not contiguous NN and MM are single T1 channels in use and Y Z are a range of T1 channels in use Single channels and ranges are separated by commas and can be combined on a command line For example an ISDN PRI link uses channel 24 for D Channel signaling and 5 20 for voice circuits T1 FRAC 5 20 24 31 Chapter 4 Command Line Interface Engage Communication BlackBond Link Encryptor User s Guide Interface Configuration TYPE T1 E1 The TYPE parameter should be set to T1 or E1 depending on the equipment to which the BlackBond is at tached T1 Interface Configuration The serial Interface commands are applicable to BlackBond T1 models The serial interface com mands include those which configure T1 DSU CSU parameters T1 DATA NORMAL INVERTED Can be set for Normal or Inverted and must match the setting of the DSU CSU on the Telco side T1 FRAMING ESF SF D4 Selects the desired E1 framing format T1 CODING B8ZS AMI Selects whether B8ZS
48. ng CRC4 El Coding HDB3 E1 TxUnderrunAIS Off Interface S3 Type El El Data Normal El Framing CRC4 El Coding HDB3 E1 TxUnderrunAIS Off 12 Host Name BlackBond Slave Host Contact No contact specified Host Location No location specified TPS Off Telnet On UserTimeout 0 SNMP Off SNMP Traps Off Interface LAN 1 AutoNeg On IP Address 192 168 1 50 24 IP Default router 0 0 0 0 Port On BroadcastRcv On Security AES On Rekey On Rekey Mode Slave Rekey Period 1 Day ClockMaster TEL2 Network Channels 1 16 Interface S1 Type El El Data Normal El Framing CRC4 El Coding HDB3 E1 TxUnderrunAIS Off Interface S2 Type El El Data Normal El Framing CRC4 El Coding HDB3 E1 TxUnderrunAIS Off Interface S3 Type El El Data Normal El Framing CRC4 El Coding HDB3 E1 TxUnderrunAIS Off Chapter 2 Installation QuickStart Engage Communication BlackBond Link Encryptor User s Guide Example BlackBond E1 TPS OPTION E1 WAN Protection Switch BlackBond Master s Tel1 is connected to external E1 circuit that is the E1 clock source Host Name BlackBond Master Host Contact No contact specified Host Location No location specified TPS Off Telnet On UserTimeout 0 SNMP Off SNMP Traps Off Interface LAN 1 AutoNeg On IP Address 192 168 1 50 24 IP Default router 0 0 0 0 Port On BroadcastRcv On Security AES On Rekey On Rekey Mode Master Rekey Period 1 Day
49. nterface Engage Communication BlackBond Link Encryptor User s Guide HOST NAME namestring Provide a unique name for the IP Tube The new host name does not take effect until a save and reset is performed Example HOST NAME Aptos IPTube Note Earlier versions of the Engage software use the term ROUTER NAME TELNET ON OFF Turns the ability to telnet into a Tube unit On and Off USER TIMEOUT Off 1 60 This setting can be turned Off or set to the number of minutes you can leave your console or telnet session idle before the system automatically logs you out If logged off you must simply log on again NOTE Setting this value to Off or zero disables automatic user logout TERM NN Allows the user to tailor the number of display lines to their terminal screen size IP DEFAULT ROUTER address Configures the IP address of the default router or gateway for this Unit This default router is the system s default router and is used when a specific interface is not set to a higher precedence default router with the Interface config command IP Default router PING dest address src address number spray Sends an ICMP ECHO message to the specified address Any source address from an interface on the IP Tube can be used This can be useful to test routes across a LAN or WAN interface By default only 1 message packet is sent A numeric value can be entered to send more than one message Also SPRAY can be used to continual
50. of the IP Tube DLT1 DLE1 models involves setting parameters for the Ethernet inter faces LAN1 and LAN2 and the Serial interfaces S1 and S2 which may be T1 or E1 interfaces The user must specify which interface is being configured with the command INTERFACE LAN1 LAN2 S1 S2 Configuration of the IP Tube GT1 GE1 involves setting parameters for the Ethernet interfaces LAN1 and LAN2 and the Serial interfaces S1 S2 S3 S4 which may be T1 or E1 interfaces The user must specify which interface is being configured with the command INTERFACE LAN1 LAN2 S1 S2 S3 S4 Configuration of the RS530 and V35 models include configuring the device port and the ethernet port Specify the port to be configred with the command INTERFACE S1 LAN1 To move up one level from Interface Config mode to Config mode enter the INTERFACE com mand with no argument To change between interfaces whether or not in Interface Config mode specify the new interface Example name s1 INTERFACE LAN 28 Chapter 4 Command Line Interface Engage Communication BlackBond Link Encryptor User s Guide Local Area Network Interfaces PORT OFF ON PORT enables or disables the Ethernet interface AUTONEGOTIATION ON OFF Enable or disable IEEE 802 3 Auto Negotiation on the Ethernet interface Warning If the device connected to LAN1 uses Auto Negotiation and LAN1 is configured to use full duplex without Auto Negotiati
51. on the other device may operate in half duplex mode by default and successful operation cannot be guaranteed DUPLEX HALF FULL Sets the duplex mode for the Ethernet interface This command only takes effect when Auto negotia tion is configured to OFF SPEED 10 100 Sets the line rate in Mbps for the Ethernet interface This command only takes effect when Auto Ne gotiation is configured to OFF Note Full Duplex and Speed of 10 has performance issues BROADCASTRCV OFF ON The Ethernet interface can be configured to disable the reception of Broadcast and Multicast packets The IP protocol uses broadcast packets to resolve the Ethernet MAC Address of the destination IP BROADCASTRCV OFF requires that the destination P Tube or the Default Router and any local de vice that wants to communicate with the P Tube needs to be configured with the MAC address of the IP Tube in its ARP table Due to the complexity involved in setting up the IP Address to Ethernet MAC addresses manually it is recommended that BroadcastRCV is set to ON unless broadcast storms are expected on the network where the IP Tubes reside For the Ethernet interface first specify INT Interface LAN1 Typically if BroadcastRCV is set to Off the IP Tube Ethernet ARP and Tube Ethernet Address need to be configured with the MAC address of the IP Tube packet s Ethernet destination Since the desti nation for the IP Tube packet will have its broadcast receive turne
52. on mode this command turns encryption OFF GENKEY A random 256 bit key is generated with the GENKEY command This key is to be used for the en cryption function on the BlackBonds At the system level enter this command and it will create a key to input into both units ENTERKEY XXXXXX the actual key is 64 hex characters On both units issue the ENTERKEY command and provide the key generated by the output of the GENKEY command 5 Chapter 2 Installation QuickStart Engage Communication BlackBond Link Encryptor User s Guide Interface Specific 11 E1 Parameters T1 Configuration Parameters The BlackBond serial interface Tel1 is configured for T1 operation The T1 clock setting is depen dent upon the source of the T1 Clock Note Unencrypted data is on the TEL1 port and encrypted data is on the TEL2 port The BlackBond s ae connected to each other on the TEL2 port The following T1 parameters must match the configuration of the T1 interface to which it is connected Interface S1 Type T1 T1 Data Normal Invert T1 LBO CSU 0dB 7 5 15 22 5 T1 Framing ESF T1 Coding B8ZS AMI T1 IdleCharacter value T1 Channels Full Fractional E1 Configuration Parameters The BlackBond E1 serial interface TEL1 is configured for E1 operation The following E1 parameters must match the configuration of the TEL1 interface to which it is connected Interface TEL1 Type E1 E1 Data Normal Invert E1 Framing
53. onsole Port for Out of Band Management e SNMP support MIB I MIB II e Remote configuration amp monitoring Power Supply e External 24 Volts AC 1Amp with standard AC plug International power sup plies available Physical e Standard 19 inch rack mount kit available e Dimensions 9 0 x 7 3 x 1 63 inches e Weight approximately 2 Ibs excluding external power adapter BlackBond Switch Settings All Models BlackBond systems contains a four position DIP Switch which is accessible by removing the unit rear panel and sliding out the motherboard The default setting for all DIP switches is OFF Switch 1 Powering cycling the unit with DIP Switch 1 ON forces the BlackBond to return to factory default set tings Factory settings include operation from Base Flash and deleting any downloaded upgrades Ensure Switch 1 is returned to the OFF position after clearing an upgrade so future upgrades can be performed successfully Switch 1 can also be used to reset the password Be sure the unit is not power cycled while switch is OFF or previous upgrades will be lost Switch 2 Must be set in the OFF position Switch 3 Switch 3 is used during manufacturing The switch must be set to OFF for normal operation Switch 4 An ON setting is used only by the manufacture for quality assurance The switch must be in OFF position for normal operation A Appendices Engage Communication BlackBond Link Encryptor User s Guide T1 and E1 Port Specificat
54. onsole port is established and a carriage return lt CR gt is entered a Login prompt will appear The default login is root No password is needed for first login A complete description of all commands is available in Chapter 4 Command Line Interface 100 Chapter 3 Installation Engage Communication CBlackBoornd Link Encryptor User s Guide Configuring the Engage BlackBond for the LAN The BlackBond can be configured with a telnet connection to the command line interface It should be configured with the following parameters for proper operation on the network e Ethernet IP address and subnet mask e Default gateway if the IP data target unit is on another IP network The configuration procedure depends on the network environment in which the BlackBond is to be installed Note Itis strongly suggested that you configure the BlackBond with its unique network identity be fore making any Ethernet or Wide Area connections Ethernet Interface Engage BlackBond systems utilize 10 100BaseT to connect to the Local Area Network Each system provides a 10 100BaseT interface for connection to an Ethernet switch or hub using a straight thru Ethernet cable For direct connection to a PC or other LAN device a 10 100BaseT crossover cable should be used 10 100BaseT cabling and crossover pinouts are provided in the Appendices BlackBond Serial Interface Options T1 Interface The T1 interface is used to connect to T1 communication equip
55. or Alternate Mark Inversion line coding is used Typically the T1 service pro vider will specify E1 Interface Configuration E1 DATA NORMAL INVERTED Can be set for NORMAL or INVERTED and must agree with the setting of the DSU CSU on the other end E1 FRAMING CRC4 FAS Selects the desired E1 framing format E1 CODING HDB3 AMI Selects whether HDB3 or Alternate Mark Inversion line coding is used Protection Switch OPTION TPS Commands TPS ON OFF Enables or disables the TPS functionality TPS gives the failover capability to the BlackBond in the event that TEL2 fails to operate Note This feature requires TEL3 or TEL4 to be available 32 Chapter 4 Command Line Interface Chapter 5 T1 E1 Interface Configuration amp Operation This chapter provides configuration details specific to the T1 E1 interfaces of the BlackBond T1 and BlackBond E1 models With built in DSU CSU interfaces these models have unique requirements regarding clocking and their interface to other T1 E1 equipment Note A T1 E1 crossover cable is typically required to connect the BlackBond T1 E1 interface to the external T1 E1 equipment Direct connections to T1 E1 lines use straight T1 E1 cables T1 E1 Timeslot Configuration Full or Fractional CHANNELS FULL FRACTIONAL NN XX NN Y Z LMM Y Z Indicates if T1 E1 interface usage is all channels or Fractional Note Fractional T1 requires an even number of Timeslots FULL will
56. ost Name BlackBond Slave Host Contact No contact specified Host Location No location specified TPS Off Telnet On UserTimeout 0 SNMP Off SNMP Traps Off Interface LAN 1 AutoNeg On IP Address 192 168 1 50 24 IP Default router 0 0 0 0 Port On BroadcastRcv On Security AES On Rekey On Rekey Mode Slave Rekey Period 1 Day ClockMaster TEL2 Network Channels Full Interface S1 Type El El Data Normal El Framing CRC4 El Coding HDB3 E1 TxUnderrunAIS Off Interface S2 Type El El Data Normal El Framing CRC4 El Coding HDB3 E1 TxUnderrunAIS Off Interface S3 Type El El Data Normal El Framing CRC4 El Coding HDB3 E1 TxUnderrunAIS Off Chapter 2 Installation QuickStart Engage Communication BlackBond Link Encryptor User s Guide Example BlackBond E1 FRACTIONAL BlackBonds are connected to external E1 WAN circuit that is the E1 clock source Host Name BlackBond Master Host Contact No contact specified Host Location No location specified TPS Off Telnet On UserTimeout 0 SNMP Off SNMP Traps Off Interface LAN 1 AutoNeg On IP Address 192 168 1 50 24 IP Default router 0 0 0 0 Port On BroadcastRcv On Security AES On Rekey On Rekey Mode Master Rekey Period 1 Day ClockMaster TEL2 Network Channels 1 16 Interface S1 Type El El Data Normal El Framing CRC4 El Coding HDB3 E1 TxUnderrunAIS Off Interface S2 Type El El Data Normal El Frami
57. t arrive at the Ethernet Interface Usu ally this indicates a problem with the Ethernet interface of the local or remote unit or a problem with the IP network TCP IP Connection 39 An IP Ping program is the best tool for troubleshooting TCP IP connectivity As a sanity check first ensure you can ping the local router If unsuccessful go back to Can t Communicate with the Local BlackBond section Chapter 6 Troubleshooting Engage Communication BlackBond Link Encryptor User s Guide Appendix A BlackBond T1 E1 Specifications T1 Specifications e All are two Port Models e Connects directly to T1 Line or to a DS1 interface with a Crossover Cable e Framing ESF or D4 e Coding B8ZS or AMI e Supports DSO assignments from 1 to 24 e Not Contguous Configuration x y Z Supported Quality of Service Support e IP Type of Service TOS CLI configurable e IANA Registered UDP Port 3175 TFTP Online Upgrade Capable FLASH ROM s e BlackBond is fully operational during upgrade Ethernet Port 10 100 Base T Full Half Ethernet LAN Protocol IP TCP UDP ICMP e Assured Delivery Protocol BlackBond Protocols e Engage BlackBond e Circuit Extension Over IP HDLC Over IP e SS7 Over IP Serial Interfaces Optional T1 DSU CSU Optional E1 DSU CSU 40 Appendices Engage Communication BlackBond Link Encryptor User s Guide Management e Telnet support with Edit and Paste Template Files e C
58. t that it is attached to LNK will indicate a steady GREEN e The Second T1 interface has an AES indicator that will be ON when AES encryption is synchronized Note AES encryption is be done on the T1 frames when AES is ON E1 Interface LEDs The BlackBond E1 provides specific information with TD and RD indicators providing status on valid framing from the E1 device or line to which the BlackBond is connected When transmitting the TD will show a blinking or steady GREEN e When receiving the RD will show a blinking or steady GREEN If the BlackBond is unable to receive valid frames from the connected equipment via the E1 line the RD will be off ENA indicates the port is available When connecting to the E1 link ST will show no color for a positive link unless a loopback has been configured e For correct framing status between the BlackBond E1 and the E1 equipment that it is attached to LNK will indicate a steady GREEN e The Second E1 interface has an AES indicator that will be ON when AES encryption is synchronized Note AES encryption is be done on the T1 frames when AES is ON 49 Chapter 3 Installation Engage Communication TT BlackBoond Link Encryptor User s Guide Internal DIP Switches BlackBond systems contain an internal four position DIP Switch which is accessible by removing the unit rear panel and sliding out the motherboard The default setting for all DIP switches is OFF Switch 1 Power cycling t
59. the RJ45 to DB15 male adapter and standard RJ45 cabling with all 8 connections SNMP Support All Engage products support SNMP Simple Network Management Protocol version 1 SNMP sup port provides access via IP to groups of administrative configuration related and statistical infor mation objects about the Engage device An IP network connection to the device and a PC with an application which provides an SNMP version 1 client are required 2000 2 2 Chapter 3 Installation Chapter 4 Command Line Interface Command Line access to the BlackBond may be made via a serial connection to the Console port or a Telnet connection to the Ethernet interface For communication through the Console port standard terminal communication software is used The console port may be used to communicate with the BlackBond locally through a terminal or remotely by dialing in through a modem Telnet part of the TCP IP Protocol Suite provides a general communications facility defining a standard method of interfacing terminal devices to each other Any standard Telnet application can be used to communicate to an Engage BlackBond provided there is IP connectivity between the User Host and the BlackBond Console Communication Serial communication to the console port should be configured for 9600 baud 1 stop bit no parity 8 bit fixed flow control none The console port is an RJ45 jack and an appropriate cable and adapter are provided with the B
60. verlP port is receiv ing T1 frames on its Port interface and transmitting them out its Ethernet interface Also reception of packets on its Ethernet interface and transmission out is Port 1 interface can be checked Repeat edly issuing the command SHOW STATISTICS short hand SH ST can help determine the source of a problem For example errors with the Ethernet interface reception of packets will slow or stop the Port interface transmission of packets Errors with Port interface reception of packets will slow or stop the expected rate of the Ethernet interface transmission of packets Certain statistics can indicate clocking problems Port interface Transmit UN under runs indicate the interface ran out of packets to transmit If the Ethernet interface is running without errors then this might indicate the transmit clock on this unit is running faster than the remote unit is clocking recep tion of data on its port interface Improper configuration of the T1 E1 clocking will result in an overrun or under run condition which causes T1 E1 periodic frame losses One of the BlackBond units must be the clock source either internal or locked onto a network source and the remote end unit uses the first unit as it s source In the case where a BlackBond is being connected to a T1 line from the Telephone company the BlackBond connected to the Telco T1 line must be set to T1 Clocking Network Packets Out Of Sequence indicates an expected packet did no
61. when a network grows beyond the number of hosts allowed for the IP address class of the site TCP Transmission Control Protocol ensures reliable sequential delivery of data TCP at each end of the connection ensures that the data is delivered to the application accurately sequential completely and free of duplicates The application passes a stream of bytes to TCP which breaks it into pieces adds a header forming a segment and then passes each segment to IP for transmission Telnet The TCP IP standard protocol for remote terminal connection service A user can telnet from the lo cal host to a host at a remote site UDP User Datagram Protocol provides simple efficient protocol which is connection less and thus un reliable The IP address contained in the UDP header is used to direct the datagram to a specific destination host Well Known Port Any set of port numbers reserved for specific uses transport level protocols TCP amp UDP Well known ports exist for echo servers time servers telnet and FTP servers Communication Link Definitions Synchronous Serial Interfaces A serial interface between two devices which provides for bi directional data transfer as well as clock ing One device the DCE provides the transmit and the receive timing to the second device the DTE A6 Glossary Engage Communication SC BlackBond Link Encryptor User s Guide Data Communication Equipment DCE This interfaces to the communi

Download Pdf Manuals

image

Related Search

Related Contents

DVC Camcorder - Ingo Devices  Infotainment  Hoshizaki KM2100SRH350 User's Manual  C5MR  竹刀のSG基準 - 製品安全協会  EVGA GeForce GTX 470 SuperClocked GeForce GTX 470 1.25GB  Nissan 2009 Altima Hybrid Automobile User Manual  System Specifications T200C/T210C  Propuesta del Grupo ALUGOM  USER MANUAL - BRK Electronics  