Home

INT-TSI

image

Contents

1. File Edit View Run Tools Window Help EI Si Lu Ei Smith s House 258 Theme 1 INT T5I Pl Gi Templates 3 H CH Synchronization ES Theme ihe Users 3 Double click on the template which is to be edited e g Basic displayed on the keypad screen when no user is logged in TSI Builder 1 0 File Edit View Run Tools Window Help DEESSET BO Projects 2 Files Start Page SET Theme 1 INT TSI SR Templates ME Default with authorization H CH Synchronization mn Theme ee Users D 2014 01 14 0932005 24 INT TSI SATEL 5 In the Properties window click on the tab title to enter the text which will be displayed in the keypad e g Welcome screen system Tab Properties amp Basic Title al Wallpaper picture jpg Icon info png Expert Label Comment 6 Click on the button to select the tab wallpaper Welcome screen Tab Properties amp Welcome screen Wallpaper picture jpg icon info png Ip Expert Label Comment 7 Click on the wallpaper which is to be used in the tab You can also add a new wallpaper by clicking on the Import button Images in JPG and PNG format can be imported When importing an image some editing tools are available They allow you to prepare SATEL IN
2. clock DTM data Z1 Z2 zones RSA RSB unused terminals intended for future applications RS 485 2 tamper switch 3 RS 232 connectors for service purposes 4 reader of microSD memory cards 5 USB MINI B socket for future applications 6 RJ 45 socket to connect the Ethernet network Provided with two LEDs The green one indicates connection to the network and data transfer and the yellow one the negotiated transmission rate ON 100 Mb OFF 10 Mb 3 1 microSD memory card On the microSD memory card e the installation file of TSI BUILDER program is provided SATEL INT TSI 3 e the keypad configuration data are stored e new keypad firmware version is placed e the events downloaded from the control panel are saved e the photos which will be used for the slide show can be placed The keypad supports the microSD and microSDHC memory cards To insert or remove the memory card you must open the keypad enclosure therefore if the alarm system works remember to enter the service mode If the microSD card is removed from the working keypad you will only be able to operate the alarm system by using the terminal After you insert the microSD card into the working keypad a window will be displayed in which you should tap to restart the keypad 3 1 1 Inserting the microSD card 1 Open the keypad enclosure see Fig 2 2 Insert the card into its slot and push until it clicks into place T
3. inhibit Bypass clearing Output MONO UN Output Bl switch state LEET Fig 10 User functions definition tab in DLOADX program 8 2 Exporting system data by means of the DloadX program 13 The DLOADX program makes it possible to export the system data file for the purposes of creating a user interface in the TSI BUILDER program The file contains names of partitions zones outputs and expansion modules user data event log ETHM 1 module s settings 14 INT TSI SATEL To export the file 1 Click in turn on File Export Import Export names to xml An Export to XML window will open 2 Select the folder to which the file is to be saved 3 Enter the file name 4 Click on the Save button 8 3 User interface Preparing a user interface which will make it possible to optimally use the capabilities offered by the INT TSI keypad requires an individual approach to each alarm system based on the INTEGRA INTEGRA Plus control panel The alarm systems differ in the way the zones and outputs are used division into partitions devices connected to the control panel etc The alarm system users may have different expectations regarding both the functions which are to be performed and how they should be run The TSI BUILDER program allows you to prepare the user interface which will not only utilize the potential of control panel but will also make the everyday operation of the alarm system easier for
4. may not exceed 15 kQ For the R2 resistor you can program value 0 In such a case the value of resistors used in the Double EOL configuration must be equal to half the value programmed for the R1 resistor the value of one resistor must not be less than 500 Q By default the following values are programmed R1 1 1 KO R2 1 1 kQ The resistor value for Single EOL configuration is the sum of R1 and R2 resistors Keypad State inspections User functions definition EOL resistance value EOL resistance value R1 1100 om R2 1100 a il Read ial write A Out Fig 8 EOL resistance value tab in DLOADX program INTEGRA Plus parameters of the EOL resistors should be defined for the mainboard zones The same parameters will be set automatically for the zones in keypads in which the value of EOL resistors is programmable Therefore the EOL resistance value tab is not available SATEL INT TSI ZEOL NC AEOL IN Fig 9 Numbering of EOL resistors Same for the NO detector T tamper A alarm M masking 8 1 4 User functions definition Code arrows you can define which functions will be started on entering the code and touching the selected arrow key Keypad State inspections User functions definition EOL resistance value Code a Not used Not used Arming Full Arming without interior zones Arming without interno zones no delays Disarmirng Alarm clearing ones bypassing
5. are saved to the microSD memory card in the keypad After synchronization of the event memory the keypad will be automatically downloading new events from the control panel The keypad event memory is unlimited which means that a greater number of events may be saved to the memory card than to the memory of the control panel The DLOADX program makes it possible to export the system data file containing e g the event log see Exporting system data by means of the DloadX program p 13 You can read in this file when creating a user interface project in the TSI BUILDER program see p 16 As a result when synchronizing the event memory the keypad will only have to download the events which took place after the file was exported This solution significantly reduces the synchronization procedure in the case of those control panels in the memory of which a large number of events is saved If the whole event memory of the control panel is to be available in the keypad the synchronization procedure must not be interrupted 8 INT TSI SATEL If the file containing the event memory becomes corrupted or deleted from the memory card then the procedure of synchronizing event memory will be started 8 Keypad configuration 8 1 Parameters and options Parameters and options of the INT TSG keypad can be programmed by means of e LCD keypad terminal P SERVICE MODE STRUCTURE HARDWARE LCD KEYPADS gt SETTINGS keypad name e DLOADX program
6. ferrite ring 6 Pass the cables through the opening in the enclosure base 7 Using wall plugs screw anchors and screws fasten the enclosure base to the wall 8 Connect the DIM CKM and COM keypad terminals to the appropriate terminals of the control panel keypad bus see Fig 4 It is recommended that the unscreened straight through cable be used for making the connection If you use the twisted pair type of cable remember that CKM clock and DTM data signals must not be sent through one twisted pair cable The wires must be run in one cable The length of cables must not exceed 300 m SATEL INT TSI 5 INTEGRA INTEGRA Plus COM KPD DTM CKM a Ee Fig 4 Connection of the keypad to the control panel 9 Connect the wires to the terminals of additional zones if any detectors are to be connected to them the detectors are to be connected in the same way as to the control panel onboard zones 10 Connect the power supply wires to the keypad terminals 12V and COM The keypad can be powered from the control panel mainboard an expander with power supply or from an additional power supply unit The table below shows requirements regarding the power wires 12V and COM if conductors with 0 5 mm diameter are used _ Distance from control panel _ Number of parallel connected wires 25 50 m 50 75 m 75 100 m In the case of INTEGRA 24 INTEGRA 32 and INTEGRA 128 WRL control panels the KPD
7. gt Structure window Hardware tab Keypads item gt keypad name The procedure of entering the service mode by means of the INT TSI keypad is described in section Programming keypad address by means of service function p 6 Shown in square brackets are the names used in keypads 8 1 1 Keypad Name individual name of the keypad up to 16 characters Partitions managed by keypad Partitions the partitions which can be armed disarmed or alarm in which may be cleared from the keypad These functions are available to the users having a suitable authority level and access to those partitions Using the service code you can operate all partitions irrespective of which partitions are operated by the keypad Show alarms of partitions Alarms the keypad can signal burglary alarms from selected partitions Show fire alarms of partitions Fire alarms the keypad can signal fire alarms from selected partitions CHIME signal of zones Chime zones the keypad can audibly signal violation of selected zones If the zone is armed violation will not trigger the CHIME signal Zone disabling CHIME Chime bps zone zone which if violated will disable the CHIME feature for specified time Bypass time Chime bps time time during which the CHIME signal will be disabled after violation of the zone which disables the signaling time is counted from the zone restore If the value 0 is programmed the signaling
8. information on the module can be added after you click on the Add button In the presented example the network address of ETHM 1 module is assigned dynamically hence it has not been exported to the XML file You can check the IP address of the module using the DLOADX program Structure window Hardware tab module name or the ETHM 1 IP MAC user function Having checked the address click on the network device to highlight it and then on the Edit button The Interface window will open Choose Project 2 Name and path r ap e anad p Ay ar Interface Doad data import J Network devices Conmecton LAN 1 Connecton LAN 1 ETHM 1 000 000 000 000 7 E CH Es Ss Network devices connected to the control panel ER that allow TS Builder to communicate with control panel e g to download names and run simulation netsh SATEL 9 Enter the network address of the ETHM 1 module Interface ETHM 1 Display as Connection LAN 1 000 000 000 000 Port 7091 Guardk key errerrrrrree E Show key 10 Click on the Connection test button Interface ETHM 1 Display as Connection LAN 1 Address 192 168 1 73 Port 7091 GuardX key eeeseeenene E Show key SATEL Tt 11 A window will be displayed with information on the connection status Click on the OK button to close the window Address 1921
9. menu displayed after right clicking on the tab KA 1014 01 14 09 32 05 Analog dock H Date Time IER System status DON Text field gt PA Indicator W Button WR Double button 2 Indicating button WW Goto button WW Filter button Zones Outputs Partitions For further information on editing templates adding widgets creating macro commands etc please refer to the TSI BUILDER program and www satel eu website If no terminal is placed on any of the template tabs a tab containing the terminal will be added automatically by the keypad 8 3 3 Saving configuration to the memory card synchronization 1 Right click on the project name File Edit View Run Tools Window Help len B Lu H gt L gt Projects Fies Start Page a Basic no author Smith s House e zm er ER E Theme 1 INT TS Be E SCH Fc 2 Inthe pop up menu click on the Build command File Edit View Run Tools Window Help k a lab Lou fal A 28 3 the BUILD SUCCESSFUL message should appear INT TSI SATEL In the Output window information on the project compilation will be displayed Finally III III KLEEKESSSEE Seed aE FTES FE BLE ceeate DD oa LA E SEET FEFFFFTFTEFEFI tritt Remove the microSD card from the keypad and insert it into the memory card reader of the computer A window will be displayed with information that a microSD card has been detected The name of
10. the keypad will inform about arming with a displayed message Quick control Control 8 if this option is enabled the user can use the zone control widgets in the template available without login start the CONTROL user function from the terminal after tapping in turn the and Di keys without entering the code Keypad zones for each of the keypad zones can be defined whether it will be used or not Tamper signaled in part Tamper in part selection of the partition in which alarm will be signaled if the keypad tamper contact is opened or the keypad is disconnected from the control panel Power supply source Power supply you can define the source from which the keypad is powered control panel mainboard expander with power supply or other power source If you select the control panel mainboard or expander with power supply the keypad SATEL INT TSI 11 backlight intensity will be reduced to approx 15 in case of loss of AC power supply of the control panel or expander 8 1 2 State inspections 1 zone state Zones if this option is enabled the user can check the state of zones on the terminal by long pressing the key with number 1 for about 3 seconds the widget presenting the state of zones will always indicate the status of all zones you can use the widget in the template available without login 4 partitions armed Partitions if this option is enabled the user can c
11. will not be disabled Quick Arm partitions Quickarm part partitions which will be armed in case of the quick arming i e without user authorization Show entry delay of partitions Entry time p the partitions for which counting the entry delay will be indicated by text appearing on the display Show exit delay of partitions Exit time part the partitions for which counting the exit delay will be indicated by text appearing on the display Alarm messages you can define whether the keypad is to display text messages about alarms in partitions Part al msg from zones Zone al msg SATEL LCD keypad addr 07 version 1 00 INT TSI Keypad State inspections User functions definition EOL resistance value Name Partitions managed by keypad z Show alarme of partitions z Show fire alarms of partitions 7 18 19 20 21 22 23 24 25 25 27 28 23 3D 31 32 Oo 34 35 39 J7 38 39 40 one disabling che Bypass time E ei Quick Arm partitions meds Show entry delay of partitions F Show eut delay of partitions A one 127 one 127 f imn LED keypad f ot used Auto backlight C l C Tamper signaled in part MII Io Date Time format 1Jan 12 00 00 jato 012 x prot preset x W Ones LED backlight keps backlight Alarm messages We Partitions Alarms W FIRE W AUS Additional options Silent PANIC aam Sign entry d
12. 68173 Port ion K m nn M 20 INT TSI SATEL 13 Click on button Next to proceed to the next step Conmection LAM 1 Connecton LAN 1 ETHM 1 192 168 1 3 r deere Slee od rer ented ele ER that allow TS Builder to co cate with control panel e g EE A o tear 14 A window will be displayed in which the INT TSI keypad will be selected as the type of target device in future besides the INT TSI keypad mobile devices will be available and selectable after clicking on Enter a name for the device or group of devices whose interface is to be identical e g Theme 1 SATEL INT TSI 21 15 Click on the Next button to proceed to the next step 16 Click on to select a graphical interface theme Restore default system properties Delete all previously imported Bez 22 INT TSI SATEL 17 Click on the Finish button A new folder will be created to which all project files will be saved The New project window will be closed The project structure will be displayed in the Projects window Restore default system properties Delete al previously imported fies 8 3 2 Editing a template first steps 1 Click on next to the target device name in the presented example Theme 1 to expand the structure ie EL ap Theme 1 INT TSI SATEL INT TSI 23 2 Click on next to the Templates to expand the list of templates
13. ILDER program should be used 1 Features e touch screen with 800 x 480 resolution e Fully customizable graphical user interface e Widgets to allow the user to operate the keypad and control the alarm system and automation devices connected to the control panel e Quick launching of different functions by means of macro commands e Displaying images from web cameras JPEG and MJPEG e Ability to display a slide show as screen saver e ARM Cortex A8 single core processor e Built in reader of microSD memory cards e Built in two 2 W speakers e 2 programmable hardwired zones support for NO and NC type detectors as well as roller shutter and vibration detectors support for Single EOL Double EOL and Triple EOL configuration Triple EOL when working with INTEGRA Plus control panels programming end of line resistor values e Tamper contact reacting to the enclosure opening or detaching from the wall 2 Specifications SUPPI VONA e 12 V DC 15 Standby Curent COnSuUMPUON EE 500 mA Maximum Current CONSUMPTION irevessisivotedesi iiris aia in EAEEREN 620 mA Supported memory Cards microSD micro SDHC Environmental class according to EN501 30 38 II A Let leie bet Elle LEE 10 C 4 55 C EAEAN EE 93 3 Enclosure dimensions width x height x uckness 196 x 129 x 22 mm 2 INT TSI SATEL 3 Keypad description Fig 1 Inside of enclosure 1 terminals COM common ground 12V power supply input CKM
14. Naren CE int tsi_i_en 12 13 Keypad INT TSI Installer Manual Firmware version 1 00 SATEL sp z 0 0 ul Schuberta 79 80 172 Gdansk POLAND tel 58 320 94 00 e info satel pl www satel eu WARNINGS The keypad should be installed by qualified personnel Read carefully this manual before proceeding to installation Changes modifications or repairs not authorized by the manufacturer shall void your rights under the warranty Warning This is a Class A product In a domestic environment this product may cause radio frequency interference in which case the user may be required to take adequate measures Section Installation and hook up contains information on how to minimize the radio interference The SATEL s goal is to continually upgrade the quality of its products which may result in alterations of their technical specifications and firmware The current information on the introduced modifications is available on our website Please visit us http www satel eu The declaration of conformity may be consulted at www satel eu ce The following symbols may be used in this manual note A caution The INT TSI keypad makes possible the operation and programming of INTEGRA and INTEGRA Plus control panels with firmware version 1 12 of 2013 11 27 or newer For programming of the keypad settings the DLOADX program version 1 12 or newer is required To set up the user interface the TSI BU
15. T TSI 25 8 Click on the OK button to confirm selection of the wallpaper and close the window 9 Click on the button to select a tab icon screen Tab Properties amp pictures jpg info png 10 Click on the icon which is to be used for the tab in the presented example the default icon will be retained You can also add a new icon by clicking on the Import button Images in JPG and PNG format can be imported for the PNG files you can use the transparency tool When importing an image some editing tools are available They allow you to prepare an icon based on the indicated image 26 INT TSI SATEL 11 Click on the OK button to confirm of the icon selection and close the window 12 Click on the Icon TSI Builder 1 0 File Edit View Run Tools Window Help Rags oe TD BOB CHE if Smith s House Ej Theme 1 INT TSI CO Templates 13 In the Properties window advanced settings of the tab will be displayed You can configure them so as to customize the tab to the needs of the keypad users Welcome screen Tab Properties amp pictures jpg TT 0 0 0 Show control panel name Show date Welcome screen Tai E SATEL INT TSI 2 14 Having configured the tab settings you can proceed to placing widgets on the tab The widgets can be placed on the tab using the drag and drop method or by means of the pop up
16. ad and insert into the computer memory card reader SATEL INT TSI 31 10 Click on the B icon Thumbnails of the pictures located in the Pictures folder on the microSD card will be additionally displayed in the gallery In the upper left corner of the thumbnail the memory card icon will be displayed its color having the following meanings grey the picture has not been saved to the card green the picture has been saved to the card 11 Click on the thumbnail to save the picture to the card or delete it from the card 10 Updating the keypad firmware The TSI Builder program automatically downloads firmware updates for the INT TSI keypad The new firmware version is saved to the memory card during configuration saving synchronization The firmware will be updated after inserting the memory card into the keypad and restarting it When the enclosure is opened in order to remove or insert the card and during updating of the keypad firmware the service mode must be active in the control panel
17. ault settings can provide support for all keypads connected to the bus irrespective of the addresses set in them In all other cases the control panel will block operation of the keypads having identical addresses The address set in the keypad determines the numbers to be given to the keypad zones see the INSTALLER MANUAL for INTEGRA or INTEGRA Plus control panels 5 1 Programming keypad address by means of service function 1 Find the tab in which the terminal is available in the keypad with factory settings tap the icon on the tab bar 2 Enter the service code by default 12345 and touch the key The user menu will be displayed 3 Touch the key The service mode will start up 4 Start the KEYPADS ADDR function P STRUCTURE HARDWARE P IDENTIFICATION KEYPADS ADDR A window will be displayed in which you can set the address after starting the function you can set the address in all Keypads connected to the control panel 5 Using the E and A keys set the address and then tap the V icon The terminal with service menu will be displayed on the screen SATEL INT TSI 7 5 2 Programming address without entering the service mode This method is useful when due to repeating addresses the keypad support has been disabled and entering the service mode is impossible 1 Turn off keypad power supply Disconnect wires from the keypad terminals CKM and DTM Short the keypad terminals CKM and DTM Turn on k
18. elay Sign exit delay Sign alarms Keys sound Sign trol in part arm Sign new trouble lw PANIC 3 wrong codes Exit delay clearing enable Show viol zones Auto Armm delay countdowr Show dizarm messages Show arm messages F M 7 GG 7 F 3 d Quick control one 128 Zone 128 f imn LCD keypad Hot used D a e 1 Living Room ei Copy Main Board k Comments Fig 6 Keypad tab in DLOADX program Power supply source Alarms you can define which alarms will be triggered from the keypad fire using the widget or terminal by long pressing the key for about 3 seconds panic using the widget or terminal by long pressing the Di key for about 3 seconds 10 INT TSI SATEL auxiliary medical using the widget or terminal by long pressing the Di key for about 3 seconds 3 wrong codes entering invalid codes three times Silent PANIC alarm Silent panic with this option enabled the panic alarm triggered from the keypad will be a silent alarm without audible alarm signal Sign entry delay Entry time s with this option enabled the keypad will audibly signal the entry delay countdown Sign exit delay Exit time sig with this option enabled the keypad will audibly signal the exit delay countdown Sign alarms Alarm signal with this option enabled the keypad will signal the alarms audibly Key so
19. eypad power supply A window will be displayed where you can set the address Using the v and A keys set the address and then tap the vV CON Turn off keypad power supply Open the keypad terminals CKM and DTM Connect wires as required to the keypad terminals CKM and DTM Turn on keypad power supply w N oe oS Se 6 Keypad identification The alarm system can only be programmed and operated from keypads that have been identified by the control panel The keypad identification function should be executed at the first start up of the control panel and then each time when adding a new keypad or changing address in a keypad supported by the control panel Disconnecting an identified keypad from the bus will trigger the tamper alarm The identification function can be run by using e the keypad P SERVICE MODE P STRUCTURE P HARDWARE P IDENTIFICATION LCD KEYPADS ID e DLOADX program gt Structure window 2 Hardware tab gt Keypads item gt Keypads identification button The procedure of entering the service mode by means of the INT TSI keypad is described in section Programming keypad address by means of service function p 6 7 Synchronizing event memory After the keypad start up a window will be displayed to inform you that synchronization of the event memory is in progress During that time the keypad is downloading events from the control panel The events read from the control panel memory
20. he card contacts should be directed toward the display 3 Close the keypad enclosure 3 1 2 Removing the microSD card 1 Open the keypad enclosure see Fig 2 2 Push the card to release it 3 Remove the card from its slot 4 Installation and hook up A Disconnect power before making any electrical connections The device is designed to be used only in the local area networks LAN It must not be connected directly to the public computer network MAN WAN Connection to the public network may only be done through a router or xDSL modem The INT TSI keypad is designed for indoor installation The place of installation should be readily accessible to the system users 1 Open the keypad enclosure see Fig 2 The enclosure opening tool shown in the illustration is included in the keypad delivery set 2 Place the enclosure base on the wall and mark the location of mounting holes 3 Drill the holes for wall plugs screw anchors d INT TSI SATEL Fig 2 Opening the enclosure 4 Install in the wall a junction box to which cables will be connected and in which a ferrite ring will be placed The purpose of the ferrite ring delivered with the keypad is to decrease the electromagnetic interference Make sure that the ferrite ring is positioned as close as possible to the enclosure 5 Wrap the cables around the ferrite ring see Fig 3 but no more than 3 turns per cable Fig 3 The cable wrapped around the
21. heck the state of partitions on the terminal by long pressing the key with number 4 for about 3 seconds the widget presenting the state of partitions will always indicate the status of all partitions you can use the widget in the template available without login Keypad State inspections User functions definition EOL resistance value kep hold dowrn one State Partition State fone bypass Partition temporary blocked Inspection KEE Trouble too long violation Entry delay e Trouble no viotations Exit delay less than 10sec Tamper alarm j 5 Exit delay more than 10sec E Alarm FIRE alarm w 4 Partitions armed Aone tamper Alarm Masking W Alam events memory Fire memory one violatior W E Trouble memory Alarm memory Tamper alarm memory Armed wi H i Trouble statis Masking memory Mot ready Al mj a China sief SE jal a il a i a a i ad Not armed MNNM hb NW one UK Hemanentlu displayed partitions SASE Fig 7 State inspections tab in DLOADX program 5 alarm events memory Alarms log if this option is enabled the user can review the alarm memory on the terminal by long pressing the key with number 5 for about 3 seconds 6 trouble memory Troubles log if this option is enabled the user can review the trouble memory on the terminal by long pressing the key with number 6 for about 3 seconds 7 trouble status Troubles
22. if this option is enabled the user can review the current troubles on the terminal by long pressing the key with number 7 for about 3 seconds the widget presenting the troubles can be used in the template available without login 12 INT TSI SATEL 8 chime on off Chime changing if this option is enabled the user can switch on off the CHIME signal in the keypad by means of the terminal long pressing the key with number 8 for about 3 seconds Zone state Zone characters you can define the symbols which will be used by the terminal to illustrate the state of zones Partition state Part characters you can define the symbols which will be used by the terminal to illustrate the state of partitions 8 1 3 EOL resistance value The resistance data are stored in the keypad Before you proceed to programming the resistor values read out the data from the keypad Read button and after the programming is completed write them to the keypad Write button These data are not read and written after you click the button in the program main menu The value of EOL resistors is programmable Depending on the control panel to which the keypad is connected INTEGRA parameters of the EOL resistors should be defined for zones in a single keypad Value of the resistors R1 and R2 is to be programmed numbering of the resistors is shown in Fig 9 You can enter values from 500 Q to 15 KQ The total resistance R1 R2
23. jects Incorrect project name 16 INT TSI SATEL 4 Click on the Next button to go to the next step Name and Project name Smith s House Project path C Users Tomasz Pocuments TSI Builder Projects Project folder C Wsers Tomasz Documents Tol Bulder Projects Smith s House 5 Click on the Browse button to indicate location of the XML file with system data see Exporting system data by means of the DloadX program p 13 or click on D to select one of the files prepared with the use of factory default settings of the alarm control Choose Project Name and path DloadX data import Nebwork devices Target device Theme incorrect fle name 6 At the window bottom the Reading data in progress will appear i Reading data in progress Next gt Finish SATEL INT TSI 17 7 After the file is read in information on the alarm system will appear at the bottom of the window Click on the Next button to proceed to the next step Data file correct Integra 128 Partitions 5 32 Si Zones 47 128 Outputs 60 128 Expanders and keypads 15 72 Users 13 248 8 Information on network devices i e ETHM 1 modules connected to the control panel will be displayed This information is contained in the XML file with the system data If the project is created based on the file with factory settings but the ETHM 1 module is connected to the control panel
24. n be only configured by using the keypad For description of how to configure these settings please refer to the user manual 9 Slide show If a slide show is to be presented as the screen saver see the INT TSI keypad user manual the pictures to be displayed must be located on the microSD card These pictures must be placed in the Pictures folder It is recommended that their size be suitable for the display resolution i e 800 x 480 pixels The BMP GIF JPG and PNG image formats are supported 9 1 Preparing pictures for slide show by means of TSI Builder program 1 Click in turn on Window gt Gallery The Gallery window will be displayed 2 Click on the x icon The Create gallery window will open 3 Enter the gallery name and then click on the OK button 4 Click on the al icon A window will open allowing you to indicate the picture which is to be imported you can indicate a JPG or PNG file 5 Having indicated the picture click on the OK button A window will open allowing you to adjust the picture to the needs of slide show in the keypad 6 Having finished the picture editing click on the OK button A window will be displayed in which you should enter the file name 7 Having entered the name click on the OK button The picture will be saved to the gallery and its thumbnail will be displayed 8 Repeat the steps 4 7 to add further pictures to the gallery 9 Remove the microSD card from the keyp
25. output cannot be used to power the INT TSI keypad You should use the OUT1 or OUT2 high current output programmed as type 41 POWER SUPPLY A function is available in the keypad which makes it possible to check if the keypad power supply is appropriate see the INT TSI keypad user manual 11 If the keypad is to be connected to the Ethernet network image from the web cameras is to be displayed connect the cable terminated with RJ 45 plug to the dedicated socket Use the cable compliant with the 100Base TX standard the same as used for connecting computer to the network It is advisable to use the flat network cable which is more flexible and secure the cable using a cable tie see Fig 5 12 Place the front panel onto the catches snap close the enclosure After the first start up of the keypad downloading of the alarm system data from the control panel will begin It may last up to 20 minutes and make using the keypad somewhat difficult during that time 6 INT TSI SATEL Fig 5 Securing the Ethernet cable 5 Addressing The keypad must have an individual address set in it e from the 0 to 3 range if it is connected to the INTEGRA 24 or INTEGRA 32 control panel e from the O to 7 range if it is connected to the INTEGRA 64 INTEGRA 128 INTEGRA 128 WRL INTEGRA 64 Plus INTEGRA 128 Plus or INTEGRA 256 Plus control panel By default address 0 is set in the keypad When started only the control panel with factory def
26. the keypad from which the card comes will be highlighted in bold font If several projects are open in the program you will be able to select the one to which the card is to be assigned by clicking on Similarly if the project includes several target devices device groups you will be able to select the one to which the card is to be assigned by clicking on le SD card assigned to device INT TSI 7 found You may assign it to a particular project SATEL INT TSI 29 5 Click on the OK button to assign the memory card to the project and target device SD card assigned to device INT TSI 7 found You may assign it to a particular project File Edit View Run Tools Window Help Fags oe TD EO Projecte Fl E Sars Smith s House Ol Em e G E Theme 1 INT TSI SP Gil Templates EE Basic no authorization IE Default with authorization Ee Synchronization GF Theme AA Users Welcome screer 7 Click on the icon to save the configuration to the memory card The Output window will display information on the course of synchronization File Edit View Run Tools Window Help Hees aert BOS 30 INT TSI SATEL 8 Successful end of the synchronization will be confirmed by a suitable message Then it will be possible to install the memory card in the keypad After restarting the keypad the new configuration will be loaded from the card 8 4 Other keypad settings some keypad settings e g volume backlight ca
27. the users The program installation file is placed on the microSD memory card delivered with the keypad it is also available for download on the www satel eu site The minimum hardware and system requirements of the TSI BUILDER program e processor Intel Core 2 Duo 1 8 GHz e RAM memory 1 GB e 7 00 MB free space on hard disk e Microsoft Windows XP operating system It is recommended that the computer have an Internet connection Thus you will be able to e automatically download updates e download names from the control panel and test the user interface provided that the ETHM 1 module is connected to the control panel 8 3 1 Creating a new project 1 Click on the icon TSI Builder 1 0 File Edit View Run Tools Window Help Sieg Oe Start Page amp SATEL INT TSI 15 2 The New project window will open In the Categories field the Base category will be highlighted which contains an entirely new project available is also the Samples category which contains some model projects prepared by SATEL Click on the Next button to proceed to the next step Finish 3 Enter the project name e g Smith s House The Browse button allows you to indicate location of the folder containing the project files if it is to be different than the default one Name and ps eg Projectpath C MkereoenaszocmenteVf ST Builder Projects Browse Project folder C Wsers Tomasz Documents Tsl Bulder Pro
28. unds when this option is enabled touching the keypad screen is confirmed by a beep Sign trbl in part arm Trbl in p arm with this option enabled the keypad signals troubles if some of the operated partitions are armed the troubles are not signaled if all partitions are armed Sign new trouble New trbl sign with this option enabled the keypad can audibly signal the occurrence of a new trouble if the TROUBLE MEMORY UNTIL REVIEW system option is enabled New trouble signaling is cleared after the troubles have been reviewed by the user Exit delay clearing enable Fin exit time with this option enabled the exit delay time in partitions with the EXIT DELAY CLEARING option enabled can be shortened by means of the widget macro command reducing the exit delay time the terminal after tapping in turn the eg and Di keys Show viol zones Zone violation with this option enabled violating the CHIME signal triggering zone result additionally in the zone name being displayed Auto Arm delay countdown Auto arm delay with this option enabled the auto arm delay countdown in partition is signaled acoustically Show disarm messages Show disarming if this option is enabled the keypad will inform about disarming with a displayed message at all times If the option is disabled only in case of disarming from the given keypad Show arm messages Show arm if this option is enabled