1. If the device will be directly connected with the local power supply network a disconnection switch with a minimum opening of 3 mm at every pole has to be included in the permanent electrical installation The device must only be connected with an electric installation carried out in compliance with the IEC standards The electric installation must be equipped with a Residual Current Device RCD with a maximum fault current of 30 mA OPERATION After you connected the effect to the mains the T 36 Pinspot starts running CLEANING AND MAINTENANCE The operator has to make sure that safety relating and machine technical installations are inspected by an expert after every four years in the course of an acceptance test 15 16 00061369 DOC Version 2 1 The operator has to make sure that safety relating and machine technical installations are inspected by a skilled person once a year The following points have to be considered during the inspection 1 All screws used for installing the devices or parts of the device have to be tighly connected and must not be corroded 2 There must not be any deformations on housings fixations and installation spots ceiling suspension trussing 3 The electric power supply cables must not show any damages material fatigue e g porous cables or sediments Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have
2. Staub kann die Isolation reduzieren was zu t dlichen Stromschl gen f hren kann St rkere Verschmut zungen im und am Ger t d rfen nur von einem Fachmann beseitigt werden Es d rfen unter keinen Umst nden Fl ssigkeiten aller Art in Steckdosen Steckverbindungen oder in irgendwelche Ger te ffnungen oder Ger teritzen eindringen Besteht der Verdacht dass auch nur minimale Fl ssigkeit in das Ger t eingedrungen sein k nnte muss das Ger t sofort allpolig vom Netz getrennt werden Dies gilt auch wenn das Ger t hoher Luftfeuchtigkeit ausgesetzt war Auch wenn das Ger t scheinbar noch funktioniert muss es von einen Fachmann berpr ft werden ob durch den Fl ssigkeitseintritt eventuell Isolationen beeintr chtigt wurden Reduzierte Isolationen k nnen t dliche Stromschl ge hervorrufen In das Ger t d rfen keine fremden Gegenst nde gelangen Dies gilt insbesondere f r Metallteile Sollten auch nur kleinste Metallteile wie Heft und B roklammern oder gr bere Metallsp ne in das Ger t gelangen so ist das Ger t sofort au er Betrieb zu nehmen und allpolig vom Netz zu trennen Durch Metallteile hervorgerufene Fehlfunktionen und Kurzschl sse k nnen t dliche Verletzungen zur Folge haben Bei der ersten Inbetriebnahme kann es zu Rauch und Geruchserzeugung kommen Hierbei handelt es sich nicht um eine St rung des Ger tes Achtung Niemals das Geh use des Pinspots w hrend des Betriebes mit blo en H nden ber hren Geh u
3. ft werden Vorgehensweise Der Pinspot sollte idealerweise au erhalb des Aufenthaltsbereiches von Personen installiert werden WICHTIG BERKOPFMONTAGE ERFORDERT EIN HOHES MAR AN ERFAHRUNG Dies beinhaltet aber beschr nkt sich nicht allein auf Berechnungen zur Definition der Tragf higkeit verwendetes Installations material und regelm ige Sicherheitsinspektionen des verwendeten Materials und des Pinspots Versuchen Sie niemals die Installation selbst vorzunehmen wenn Sie nicht ber eine solche Qualifikation verf gen sondern beauftragen Sie einen professionellen Installateur Unsachgem e Installationen k nnen zu Verletzungen und oder zur Besch digung von Eigentum f hren Der Pinspot muss au erhalb des Handbereichs von Personen installiert werden Wenn der Pinspot von der Decke oder hochliegenden Tr gern etc abgeh ngt werden soll muss immer mit Traversensystemen gearbeitet werden Der Pinspot darf niemals frei schwingend im Raum befestigt werden Achtung Pinspots k nnen beim Herabst rzen erhebliche Verletzungen verursachen Wenn Sie Zweifel an der Sicherheit einer m glichen Installationsform haben installieren Sie den Pinspot NICHT Vergewissern Sie sich vor der Montage dass die Montagefl che mindestens die 10 fache Punktbelastung des Eigengewichtes des Pinspots aushalten kann BRANDGEFAHR Achten Sie bei der Installation des Ger tes bitte darauf dass sich im Abstand von mind 0 5 m keine leicht entflammbare
4. N he von Hitze oder K ltequellen bringen Bei Missachtung kann es zu Besch digungen der Netzleitung zu Brand oder zu t dlichen Stromschl gen kommen Die Kabeleinf hrung oder die Kupplung am Ger t d rfen nicht durch Zug belastet werden Es muss stets eine ausreichende Kabell nge zum Ger t hin vorhanden sein Andernfalls kann das Kabel besch digt werden was zu t dlichen Stromschl gen f hren kann Achten Sie darauf dass die Netzleitung nicht gequetscht oder durch scharfe Kanten besch digt werden kann berpr fen Sie das Ger t und die Netzleitung in regelm igen Abst nden auf Besch digungen Werden Verl ngerungsleitungen verwendet muss sichergestellt werden dass der Adernquerschnitt f r die ben tigte Stromzufuhr des Ger tes zugelassen ist Alle Warnhinweise f r die Netzleitung gelten auch f r evtl Verl ngerungsleitungen Ger t bei Nichtbenutzung und vor jeder Reinigung vom Netz trennen Fassen Sie dazu den Netzstecker an der Grifflache an und ziehen Sie niemals an der Netzleitung Ansonsten kann das Kabel und der Stecker besch digt werden was zu t dlichen Stromschl gen f hren kann Sind Stecker oder Ger teschalter z B durch Einbau nicht erreichbar so muss netzseitig eine allpolige Abschaltung vorgenommen werden Wenn der Netzstecker oder das Ger t staubig ist dann muss es au er Betrieb genommen werden der Stromkreis muss allpolig unterbrochen werden und das Ger t mit einem trockenen Tuch gereinigt werden
5. ATA ccavecuenssenudvegeueenecaneetencecssedeaeazede 10 OPERATING DETERMINATIONS 6c ciccccccccctccececcuceccccedeceeceteesenedduencdeneuessceuedsecesscessieceddedccenuueeduvendercecsteesientdde 12 INSTALLATION oi ccd ccccecictcs ects cane eis BOEHRAAGECALENFELPEREHEFELREFENELREREEETEFREEREILREEEEEEPEEERTERLEEE ORSCHLEEIEPEEREEFLERERETTORREEEFPELEERES 13 Installing Replacing the lamp 4 ee 2 en ee alien 13 RiggiNg 2 2 einnehmen Olean eee 13 Connection with the Mains tassisin aii aaea edad adeadeasuhdidansabaddeanbadsacsebaadtessued s 15 OPERATION crassana aiana 15 CLEANING AND MAINTENANCE 6 cccccccccccececccceszeietcccecegeerecedeeeesdenectaceuecgcnuedsexevscesccececdeeceusuencnensedtteemeceesieesaee 15 TECHNICAL SPECIFICATIONS wisiccccseccccccssccccccsns cceeciseccccinnectiestecccensnesstanstesticnsnteccansteesccaneestecneaesseennnectaeenees 16 Diese Bedienungsanleitung gilt fur die Artikelnummern This user manual is valid for the article numbers 50800365 50800410 Das neueste Update dieser Bedienungsanleitung finden Sie im Internet unter You can find the latest update of this user manual in the Internet under www eurolite de 2 16 00061369 DOC Version 2 1 Deutsch BEDIENUNGSANLEITUNG euro jle T 36 Pinspot ACHTUNG Ger t vor Feuchtigkeit und N sse sch tzen Vor Offnen des Ger tes vom Netz trennen Alle Personen die mit der Aufstellung Inbetriebnahme Bedienung Wartung und In
6. ENSGEFAHR Bei der Installation sind insbesondere die Bestimmungen der BGV C1 und EN 60598 2 17 zu beachten Die Installation darf nur vom autorisierten Fachhandel ausgef hrt werden 6 16 00061369 DOC Version 2 1 Die Aufhangevorrichtungen des Pinspots muss so gebaut und bemessen sein dass sie 1 Stunde lang ohne dauernde sch dliche Deformierung das 10 fache der Nutzlast aushalten kann Die Installation muss immer mit einer zweiten unabh ngigen Aufh ngung z B einem geeigneten Fangnetz erfolgen Diese zweite Aufh ngung muss so beschaffen und angebracht sein dass im Fehlerfall der Hauptaufh ngung kein Teil der Installation herabfallen kann W hrend des Auf Um und Abbaus ist der unn tige Aufenthalt im Bereich von Bewegungsfl chen auf Beleuchterbr cken unter hochgelegenen Arbeitspl tzen sowie an sonstigen Gefahrbereichen verboten Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen vor der ersten Inbetriebnahme und nach wesentlichen nderungen vor der Wiederinbetriebnahme durch Sachverst ndige gepr ft werden Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen mindestens alle vier Jahre durch einen Sachverst ndigen im Umfang der Abnahmepr fung gepr ft werden Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen mindestens einmal j hrlich durch einen Sachkundigen gepr
7. Lampeninstallation Lampenwechsel LEBENSGEFAHR Lampe nur bei ausgeschaltetem Ger t einsetzen Ger t allpolig von der Netzspannung trennen ACHTUNG Die Lampe muss gewechselt werden wenn diese besch digt ist oder sich durch W rme verformt hat Vor dem Wechseln der Lampe das Ger t allpolig von der Netzspannung trennen und die Lampe unbedingt erst abk hlen lassen ca 5 Minuten Beachten Sie auch unbedingt die Hinweise des Lampenherstellers Setzen Sie keine Lampen mit einer h heren Leistungsangabe ein Lampen mit einer h heren Leistung ent wickeln h here Temperaturen f r die das Ger t nicht ausgelegt ist Bei Zuwiderhandlungen erlischt die Ga rantie Zur Installation ben tigen Sie eine 6 V 30 W PAR 36 Lampe Die verwendete Lampe erreicht Temperaturen von bis zu 130 C Vorgehensweise Schritt 1 Dr cken Sie den Lampenklemmring im Pinspot zusammen und entnehmen Sie ihn aus dem Geh use Schritt 2 Wird eine defekte Lampe ausgetauscht entfernen Sie zun chst die defekte Lampe aus dem Pinspot und l sen Sie die Kabel Schritt 3 L sen Sie die zwei Schrauben an der neuen 6 V 30 W PAR 36 Lampe mit einem Schraubendreher Schritt 4 Schlie en Sie die Kabel des Pinspots an die neue Lampe an Schritt 5 Ziehen Sie die Schrauben fest Schritt 6 Legen Sie die Lampe in den Pinspot ein so dass die Lampe auf dem Wulst aufliegt Schritt 7 Fixieren Sie die Lampe mit dem Lampenklemmring Pinspotmontage LEB
8. as Geh use darf niemals umliegende Gegenst nde oder Fl chen ber hren Achten Sie bei der Montage beim Abbau und bei der Durchf hrung von Servicearbeiten darauf dass der Bereich unterhalb des Montageortes abgesperrt ist Das Ger t ist immer mit einem geeigneten Sicherungsseil zu sichern Die maximale Umgebungstemperatur T 45 C darf niemals berschritten werden Nehmen Sie den Spot erst in Betrieb nachdem Sie sich mit seinen Funktionen vertraut gemacht haben Lassen Sie den Spot nicht von Personen bedienen die sich nicht mit dem Spot auskennen Wenn Spots nicht mehr korrekt funktionieren ist das meist das Ergebnis von unsachgem er Bedienung 5 16 00061369 DOC Version 2 1 Reinigen Sie den Spot niemals mit L sungsmitteln oder scharfen Reinigungsmitteln sondern verwenden Sie ein weiches und angefeuchtetes Tuch Soll das Ger t transportiert werden verwenden Sie bitte die Originalverpackung um Transportsch den zu vermeiden Achten Sie bitte unbedingt darauf dass das Ger t im Lieferzustand verpackt wird Beachten Sie bitte dass eigenm chtige Ver nderungen an dem Spot aus Sicherheitsgr nden verboten sind Wird der Spot anders verwendet als in dieser Bedienungsanleitung beschrieben kann dies zu Sch den am Produkt f hren und der Garantieanspruch erlischt Au erdem ist jede andere Verwendung mit Gefahren wie z B Kurzschluss Brand elektrischem Schlag Lampenexplosion Abst rzen etc verbunden INSTALLATION
9. comes void Furthermore any other operation may lead to dangers like short circuit burns electric shock lamp explosion crash etc INSTALLATION Installing Replacing the lamp DANGER TO LIFE Only install the lamp with the device switched off Disconnect from mains before CAUTION The lamp has to be replaced when it is damaged or deformed due to the heat Before replacing the lamp unplug mains lead and let the lamp cool down approx 5 minutes Please follow the lamp manufacturer s notes Do not install lamps with a higher wattage Lamps with a higher wattage generate temperatures the device was not designed for Damages caused by non observance are not subject to warranty For the installation you need one 6 V 30 W PAR 36 lamp During the operation the lamp reaches temperatures of up to 130 C Procedure Step 1 Please remove the fixation ring by pressing it together Step 2 If replacing the lamp remove the old lamp from the pinspot and loosen the wires Step 3 Loosen the screws on the new 6 V 30W PAR 36 lamp with an appropriate screwdriver Step 4 Connect the wires with the lamp using an appropriate screwdriver Step 5 Tighten the screws Step 6 Insert the lamp in the housing Step 7 Fix the lamp with the fixation ring Rigging DANGER TO LIFE Please consider the EN 60598 2 17and the respective national standards during the installation The installation must only be carried out by an authorize
10. complying with DIN 56927 quick links complying with DIN 56927 shackles complying with DIN EN 1677 1 and BGV C1 carbines The safety bonds quick links shackles and the carbines must be sufficiently dimensioned and used correctly in accordance with the latest industrial safety regulations e g BGV C1 BGI 810 3 Please note for overhead rigging in public or industrial areas a series of safety instructions have to be followed that this manual can only give in part The operator must therefore inform himself on the current safety instructions and consider them The manufacturer cannot be made liable for damages caused by incorrect installations or insufficient safety precautions Pull the safety bond through the hole in the mounting bracket and over the trussing system or a safe fixation spot Insert the end in the quick link with screw cap and tighten the safety screw The maximum drop distance must never exceed 20 cm A safety bond which already hold the strain of a crash or which is defective must not be used again Adjust the desired inclination angle via the mounting bracket and tighten the fixation screws DANGER TO LIFE Before taking into operation for the first time the installation has to be approved by an expert Connection with the mains Connect the device to the mains with the power plug The occupation of the connection cables is as follows Cable Pin _ International Attention The earth has to be connected
11. d dealer The installation of the Pinspot has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation 13 16 00061369 DOC Version 2 1 The installation must always be secured with a secondary safety attachment e g an appropriate catch net This secondary safety attachment must be constructed in a way that no part of the installation can fall down if the main attachment fails When rigging derigging or servicing the fixture staying in the area below the installation place on bridges under high working places and other endangered areas is forbidden The operator has to make sure that safety relating and machine technical installations are approved by an expert before taking into operation for the first time and after changes before taking into operation another time The operator has to make sure that safety relating and machine technical installations are approved by an expert after every four year in the course of an acceptance test The operator has to make sure that safety relating and machine technical installations are approved by a skilled person once a year Procedure The Pinspot should be installed outside areas where persons may walk by or be seated IMPORTANT OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE including but not limited to calculating working load limits installation material being used and periodic safety inspection of all installation materia
12. eat moisture or dust There should not be any cables lying around You endanger your own and the safety of others The symbol d m determines the minimum distance from lighted objects The minimum distance between light output and the illuminated surface must be more than 0 5 meters This spot is only allowed for an installation via the mounting bracket In order to safeguard sufficient ventilation leave 50 cm of free space around the spot The housing must never touch surrounding surfaces or objects Make sure that the area below the installation place is blocked when rigging derigging or servicing the fixture Always fix the device with an appropriate safety bond 12 16 00061369 DOC Version 2 1 The maximum ambient temperature T 45 C must never be exceeded Operate the spot only after having become familiarized with its functions Do not permit operation by persons not qualified for operating the spot Most damages are the result of unprofessional operation Never use solvents or aggressive detergents in order to clean the device Rather use a soft and damp cloth Please use the original packaging if the device is to be transported Make sure that you pack the device in the original state Please consider that unauthorized modifications on the spot are forbidden due to safety reasons If this spot will be operated in any way different to the one described in this manual the product may suffer damages and the guarantee be
13. eurolle BEDIENUNGSANLEITUNG USER MANUAL T 36 Pinspot Nachdruck verboten F r weiteren Gebrauch aufbewahren 5 Copyright Keep this manual for future needs Reproduction prohibited MULTI LANGUAGE INSTRUCTIONS Inhaltsverzeichnis Table of contents EINF HRUNG 2 nee ernennen 3 NOPE PUNMT ANG 25 cscs sca cea WEIHER E TE EHER Gente 3 SICHERHEITSHINWEISE 2 2 2 ss4 224224 00 0200000 00200000 kana aaa a Aa a AEE NE E Ekaa ENNAN S 3 BESTIMMUNGSGEM RE VERWENDUNG uuunsnessnsunnnsnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 5 INSTALLATION 4 s2 2444025 0044400000 anna na aa aa na Dean area rend 6 Lampeninstallation Lampenwechsel 44444440004H4nnH nn nnnnnnnnennnnnnnennnnnnnennnnnnnnnnnnennnnnnnennnnnennnenrnnen 6 Pinspolmontage u 2 ee Hei heben een ee 6 Anschl ss ans Notz asirica aaa a a aeia ee denna ei 8 BEDIENUNG 6esicetsccsccasconnscacecentectennicesteanntececertevadeedeaseceatevectoed teste E EAA E REAN AE EEEE EERE ENSA SEREEN EN 8 REINIGUNG UND WARTUNG 4 22 242 42 2 2822440000400 0022 na ea nah 8 TECHNISCHE DATEN 520u 2220 nee nen 9 INTRODUC TION oe ci css cte cessed ERRAFBPERER ANDERE AANDEHLERLBLUEEHESELRENEAELAHEERFTEEREEEFUEREEEFTEPREFUOEDEREFFUELHEHEFELCLERESEEEREREAAPEREFEFEFLRFERS 10 Delivery inel des u ea liebe 10 SAFETY INSTRUC MONS z 2 4 222244 44242222008 cneneeedcceutedcawetes AAAA ATA
14. he dealer will not accept liability for any resulting defects or problems 10 16 00061369 DOC Version 2 1 If the pinspot has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation water might damage your pinspot Leave the pinspot switched off until it has reached room temperature Please make sure that there are no obvious transport damages Should you notice any damages on the A C connection cable or on the casing do not take the pinspot into operation and immediately consult your local dealer This pinspot falls under protection class I The power plug must only be plugged into a protection class outlet The voltage and frequency must exactly be the same as stated on the pinspot Wrong voltages or power outlets can lead to the destruction of the pinspot and to mortal electrical shock Always plug in the power plug last The power plug must always be inserted without force Make sure that the plug is tightly connected with the outlet Never let the power cord come into contact with other cables Handle the power cord and all connections with the mains with particular caution Never touch them with wet hands as this could lead to mortal electrical shock Never modify bend strain mechanically put pressure on pull or heat up the power cord Never operate next to sources of heat or cold Disregard can lead to power cord damages fire or mortal electrical shoc
15. ighting effects are not designed for permanent operation Consistent operation breaks will ensure that the spot will serve you for a long time without defects Do not shake the spot Avoid brute force when installing or operating the spot When choosing the installation spot please make sure that the spot is not exposed to extreme heat moisture or dust There should not be any cables lying around You endanger your own and the safety of others This spot must never be operated or stockpiled in sourroundings where splash water rain moisture or fog may harm the spot Moisture or very high humidity can reduce the insulation and lead to mortal electrical shocks When using smoke machines make sure that the spot is never exposed to the direct smoke jet and is installed in a distance of 0 5 meters between smoke machine and spot The room must only be saturated with an amount of smoke that the visibility will always be more than 10 meters The ambient temperature must always be between 5 C and 45 C Keep away from direct insulation particularly in cars and heaters The relative humidity must not exceed 50 with an ambient temperature of 45 C This spot must only be operated in an altitude between 20 and 2000 m over NN Never use the spot during thunderstorms Over voltage could destroy the spot Always disconnect the spot during thunderstorms When choosing the installation spot please make sure that the spot is not exposed to extreme h
16. in BEDIENUNG Sobald Sie den Pinspot mit dem Stromkreis verbunden haben beginnt die Lampe zu leuchten REINIGUNG UND WARTUNG Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen mindestens alle vier Jahre durch einen Sachverst ndigen im Umfang der Abnahmepr fung gepr ft werden 8 16 00061369 DOC Version 2 1 Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen mindestens einmal j hrlich durch einen Sachkundigen gepr ft werden Dabei muss unter anderem auf folgende Punkte besonders geachtet werden 1 Alle Schrauben mit denen das Ger t oder Ger teteile montiert sind m ssen fest sitzen und d rfen nicht korrodiert sein 2 An Geh use Befestigungen und Montageort Decke Abh ngung Traverse d rfen keine Verformungen sichtbar sein 3 Die elektrischen Anschlussleitungen d rfen keinerlei Besch digungen Materialalterung z B por se Leitungen oder Ablagerungen aufweisen Weitere auf den jeweiligen Einsatzort und die Nutzung abgestimmte Vorschriften werden vom sachkundigen Installateur beachtet und Sicherheitsm ngel behoben LEBENSGEFAHR Vor Wartungsarbeiten unbedingt allpolig vom Netz trennen Das Ger t sollte regelm ig von Verunreinigungen wie Staub usw gereinigt werden Verwenden Sie zur Reinigung ein fusselfreies angefeuchtetes Tuch Auf keinen Fall Alkohol oder irgendwelche L sungsmittel zur Reinigung ve
17. jle T 36 Pinspot CAUTION Keep this device away from rain and moisture Unplug mains lead before opening the housing For your own safety please read this user manual carefully before you initially start up Every person involved with the installation operation and maintenance of this device has to be qualified follow the instructions of this manual consider this manual to be part of the total product keep this manual for the entire service life of the product pass this manual on to every further owner or user of the product download the latest version of the user manual from the Internet INTRODUCTION Thank you for having chosen a EUROLITE T 36 Pinspot If you follow the instructions given in this manual we are sure that you will enjoy this device for a long period of time Delivery includes 1 Device with installed illuminant 1 User manual Unpack your T 36 Pinspot SAFETY INSTRUCTIONS CAUTION Be careful with your operations With a dangerous voltage you can suffer a dangerous electric shock when touching the wires This pinspot has left our premises in absolutely perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual IE Important Damages caused by the disregard of this user manual are not subject to warranty T
18. k The cable insert or the female part in the pinspot must never be strained There must always be sufficient cable to the pinspot Otherwise the cable may be damaged which may lead to mortal damage Make sure that the power cord is never crimped or damaged by sharp edges Check the pinspot and the power cord from time to time If extension cords are used make sure that the core diameter is sufficient for the required power consumption of the pinspot All warnings concerning the power cords are also valid for possible extension cords Always disconnect from the mains when the pinspot is not in use or before cleaning it Only handle the power cord by the plug Never pull out the plug by tugging the power cord Otherwise the cable or plug can be damaged leading to mortal electrical shock If the power plug or the power switch is not accessible the pinspot must be disconnected via the mains If the power plug or the pinspot is dusty the pinspot must be taken out of operation disconnected and then be cleaned with a dry cloth Dust can reduce the insulation which may lead to mortal electrical shock More severe dirt in and at the pinspot should only be removed by a specialist There must never enter any liquid into power outlets extension cords or any holes in the housing of the pinspot If you suppose that also a minimal amount of liquid may have entered the pinspot it must immediately be disconnected This is also valid if the pinspot was e
19. l and the Pinspot If you lack these qualifications do not attempt the installation yourself but instead use a professional structural rigger Improper installation can result in bodily injury and or damage to property The Pinspot has to be installed out of the reach of people If the Pinspot shall be lowered from the ceiling or high joists professional trussing systems have to be used The Pinspot must never be fixed swinging freely in the room Caution Pinspots may cause severe injuries when crashing down If you have doubts concerning the safety of a possible installation do NOT install the Pinspot Before rigging make sure that the installation area can hold a minimum point load of 10 times the Pinspot s weight DANGER OF FIRE When installing the device make sure there is no highly inflammable material decoration articles etc within a distance of min 0 5 m Mount the Pinspot with the mounting bracket to your trussing system using an appropriate clamp 1 Trussing 2 Hook 3 Mounting bracket 4 Fixation screw 5 Fixation ring 6 PAR 36 lamp 7 Pinspot housing 8 Safety bond hole 9 Safety bond 10 Quick link 14 16 00061369 DOC Version 2 1 or Mount the Pinspot with the mounting bracket to the desired installation spot Do only use an appropriate screw and make sure that the screw is properly connected with the ground For overhead use always install an appropriate safety bond You must only use safety bonds
20. n Materialien Deko etc befinden Befestigen Sie den Pinspot mit dem H ngeb gel ber einen geeigneten Haken an Ihrem Traversensystem 1 Traverse 2 Haken 3 H ngeb gel 4 Feststellschraube 5 Lampenklemmring 6 PAR 36 Lampe 7 Pinspotgeh use 8 Fangseilloch 9 Sicherheitsfangseil 10 Schnellverschlussglied 7 16 00061369 DOC Version 2 1 oder Bringen Sie den Pinspot mit dem Montageb gel am gew nschten Installationsort an Verwenden Sie eine geeignete Schraube und vergewissern Sie sich dass die Schraube fest mit dem Untergrund verbunden ist Sichern Sie das Gerat bei Uberkopfmontage immer mit einem geeigneten Sicherungsseil Es d rfen nur Sicherungsseile gem DIN 56927 Schnellverbindungsglieder gem DIN 56927 Sch kel gem DIN EN 1677 1 und BGV C1 Kettbiner eingesetzt werden Die Fangseile Schnellverbindungsglieder Sch kel und Kettbiner m ssen auf Grundlage der aktuellsten Arbeitsschutzbestimmungen z B BGV C1 BGI 810 3 ausreichend dimensioniert sein und korrekt angewendet werden Bitte beachten Sie Bei berkopfmontage in ffentlichen bzw gewerblichen Bereichen ist eine F lle von Vorschriften zu beachten die hier nur auszugsweise wiedergegeben werden k nnen Der Betreiber muss sich selbst ndig um die Beschaffung der geltenden Sicherheitsvorschriften bem hen und diese einhalten Der Hersteller haftet nicht f r Sch den die durch unsachgem e Installation und unzureichende Sicher hei
21. rwenden Reinigen Sie das Innere des Projektors mindestens einmal im Jahr mit einem Staubsauger oder einer Luftb rste Im Ger teinneren befinden sich au er der Lampe keine zu wartenden Teile Wartungs und Servicearbeiten sind ausschlie lich dem autorisierten Fachhandel vorbehalten Bitte beachten Sie auch die Hinweise unter Lampeninstallation Lampenwechsel Sollten einmal Ersatzteile ben tigt werden verwenden Sie bitte nur Originalersatzteile Wenn die Anschlussleitung dieses Ger tes besch digt wird muss sie durch den autorisierten Fachhandel ersetzt werden um Gef hrdungen zu vermeiden Sollten Sie noch weitere Fragen haben steht Ihnen Ihr Fachh ndler jederzeit gerne zur Verf gung TECHNISCHE DATEN Spannungsversorgung 230 V AC 50 Hz Gesamtanschlusswert Passende Lampe 6 V 30 W PAR 36 Maximale Umgebungstemperatur T Maximale Leuchtentemperatur im Beharrungszustand T Zubehor Best Nr GE 4515 PAR 36 6 4V 30W VNSP 100h 88061000 OMNILUX PAR 36 6 4V 30W G53 VNSP 200h 88061005 GE 4511 PAR 36 6 2V 30W WEL 300h 88061200 GE H4515 PAR 36 6V 30W halo 100h 88062000 Farbrad mit Motor fur Punktstrahler T 36 50805090 Standplatte fur Pinspot schwarz 50800440 Sicherungsseil AG 5 3x600mm bis 5kg 58010360 Bitte beachten Sie Technische nderungen ohne vorherige Ank ndigung und Irrtum vorbehalten euro it berman 9 16 00061369 DOC Version 2 1 English USER MANUAL euro
22. se erw rmt sich Vermeiden Sie es den Pinspot in kurzen Intervallen an und auszuschalten z B Sekundentakt da ansonsten die Lebensdauer der Lampe erheblich reduziert werden w rde 4 16 00061369 DOC Version 2 1 GESUNDHEITSRISIKO Blicken Sie niemals direkt in die Lichtquelle da bei empfindlichen Menschen u U epileptische Anf lle ausgel st werden k nnen gilt besonders f r Epileptiker Kinder und Laien vom Ger t fern halten Das Ger t darf niemals unbeaufsichtigt betrieben werden ACHTUNG F r ausreichenden Splitterschutz muss gesorgt werden BESTIMMUNGSGEM RE VERWENDUNG Bei diesem Spot handelt es sich um einen Effektstrahler mit dem sich dekorative Lichteffekte erzeugen lassen Dieses Produkt ist nur f r den Anschluss an 230 V 50 Hz Wechselspannung zugelassen und wurde ausschlie lich zur Verwendung in Innenr umen konzipiert Dieser Spot ist f r professionelle Anwendungen z B auf B hnen in Diskotheken Theatern etc vorgesehen Lichteffekte sind nicht f r den Dauerbetrieb konzipiert Denken Sie daran dass konsequente Betriebspausen die Lebensdauer des Spots erh hen Vermeiden Sie Ersch tterungen und jegliche Gewaltanwendung bei der Installation oder Inbetriebnahme des Spots Achten Sie bei der Wahl des Installationsortes darauf dass der Spot nicht zu gro er Hitze Feuchtigkeit und Staub ausgesetzt wird Vergewissern Sie sich dass keine Kabel frei herumliegen Sie gef hrden Ihre eigene
23. standhaltung dieses Ger tes zu tun haben m ssen entsprechend qualifiziert sein diese Bedienungsanleitung genau beachten die Bedienungsanleitung als Teil des Produkts betrachten die Bedienungsanleitung w hrend der Lebensdauer des Produkts behalten die Bedienungsanleitung an jeden nachfolgenden Besitzer oder Benutzer des Produkts weitergeben sich die letzte Version der Anleitung im Internet herunter laden EINF HRUNG Wir freuen uns dass Sie sich f r einen EUROLITE T 36 Pinspot entschieden haben Wenn Sie nachfolgende Hinweise beachten sind wir sicher dass Sie lange Zeit Freude an Ihrem Kauf haben werden Lieferumfang 1 Ger t mit eingebautem Leuchtmittel 1 Bedienungsanleitung Nehmen Sie den T 36 Pinspot aus der Verpackung SICHERHEITSHINWEISE ACHTUNG Seien Sie besonders vorsichtig beim Umgang mit gef hrlicher Netzspannung Bei die ser Spannung k nnen Sie einen lebensgef hrlichen elektrischen Schlag erhalten Dieses Ger t hat das Werk in sicherheitstechnisch einwandfreiem Zustand verlassen Um diesen Zustand zu erhalten und einen gefahrlosen Betrieb sicherzustellen muss der Anwender die Sicherheitshinweise und die Warnvermerke unbedingt beachten die in dieser Bedienungsanleitung enthalten sind IE Unbedingt lesen Bei Sch den die durch Nichtbeachtung der Anleitung verursacht werden erlischt der Garantiean spruch F r daraus resultierende Folgesch den bernimmt der Hers
24. teller keine Haftung 3 16 00061369 DOC Version 2 1 Das Ger t darf nicht in Betrieb genommen werden nachdem es von einem kalten in einen warmen Raum gebracht wurde Das dabei entstehende Kondenswasser kann unter Umst nden Ihr Ger t zerst ren Lassen Sie das Ger t solange uneingeschaltet bis es Zimmertemperatur erreicht hat Bitte berpr fen Sie vor der ersten Inbetriebnahme ob kein offensichtlicher Transportschaden vorliegt Sollten Sie Sch den an der Netzleitung oder am Geh use entdecken nehmen Sie das Ger t nicht in Betrieb und setzen sich bitte mit Ihrem Fachh ndler in Verbindung Der Aufbau entspricht der Schutzklasse Der Netzstecker darf nur an eine Schutzkontakt Steckdose angeschlossen werden deren Spannung und Frequenz mit dem Typenschild des Ger tes genau bereinstimmt Ungeeignete Spannungen und ungeeignete Steckdosen k nnen zur Zerst rung des Ger tes und zu t dlichen Stromschl gen f hren Den Netzstecker immer als letztes einstecken Der Netzstecker muss dabei gewaltfrei eingesetzt werden Achten Sie auf einen festen Sitz des Netzsteckers Lassen Sie die Netzleitung nicht mit anderen Kabeln in Kontakt kommen Seien Sie vorsichtig beim Umgang mit Netzleitungen und anschl ssen Fassen Sie diese Teile nie mit feuchten H nden an Feuchte H nde k nnen t dliche Stromschl ge zur Folge haben Netzleitungen nicht ver ndern knicken mechanisch belasten durch Druck belasten ziehen erhitzen und nicht in die
25. to be removed DANGER TO LIFE Disconnect from mains before starting maintenance operation We recommend a frequent cleaning of the device Please use a moist lint free cloth Never use alcohol or solvents The interior of the device should be cleaned at least annually using a vacuum cleaner or an air jet There are no serviceable parts inside the device except for the lamp Maintenance and service operations are only to be carried out by authorized dealers Please refer to the instructions under Installing Replacing the lamp Should you need any spare parts please use genuine parts If the power supply cable of this device becomes damaged it has to be replaced by authorized dealers only in order to avoid hazards Should you have further questions please contact your dealer TECHNICAL SPECIFICATIONS 40 W 1 kg Accessories No GE 4515 PAR 36 6 4V 30W VNSP 100h 88061000 OMNILUX PAR 36 6 4V 30W G53 VNSP 200h 88061005 GE 4511 PAR 36 6 2V 30W WEL 300h 88061200 GE H4515 PAR 36 6V 30W halo 100h 88062000 Color wheel with motor for Pinspot T 36 50805090 Stand for Pinspot black 50800440 Safety bond AG 5 3x600mm up to 5kg 58010360 Please note Every information is subject to change without prior notice 21 06 2011 eu 0 eS Germany 16 16 00061369 DOC Version 2 1
26. tsvorkehrungen verursacht werden H ngen Sie das Sicherheitsfangseil an dem Fangseilloch im H ngeb gel ein und f hren Sie es ber die Traverse bzw einen sicheren Befestigungspunkt H ngen Sie das Ende in dem Schnellverschlussglied ein und ziehen Sie die Sicherungsmutter gut fest Der maximale Fallabstand darf 20 cm nicht berschreiten Ein Sicherungsseil das einmal der Belastung durch Absturz ausgesetzt war oder besch digt ist darf nicht mehr als Sicherungsseil eingesetzt werden Stellen Sie den Neigungswinkel ber den H ngeb gel ein und ziehen Sie die Feststellschrauben gut fest LEBENSGEFAHR Vor der ersten Inbetriebnahme muss die Einrichtung durch einen Sachverst ndigen gepr ft werden Anschluss ans Netz Schlie en Sie das Ger t ber den Netzstecker ans Netz an Die Belegung der Anschlussleitungen ist wie folgt Leitung Pn International Au enleiter Blau Neutralleiter N Gelb Gr n Schutzleiter Hinweis Der Schutzleiter muss unbedingt angeschlossen werden Wenn das Ger t direkt an das rtliche Stromnetz angeschlossen wird muss eine Trennvorrichtung mit mindestens 3 mm Kontakt ffnung an jedem Pol in die festverlegte elektrische Installation eingebaut werden Das Ger t darf nur an eine Elektroinstallation angeschlossen werden die den VDE Bestimmungen DIN VDE 0100 entspricht Die Hausinstallation muss mit einem Fehlerstromschutzschalter RCD mit 30 mA Bemessungsdifferenzstrom ausgestattet se
27. und die Sicherheit Dritter Der Spot darf nicht in einer Umgebung eingesetzt oder gelagert werden in der mit Spritzwasser Regen Feuchtigkeit oder Nebel zu rechnen ist Feuchtigkeit oder sehr hohe Luftfeuchtigkeit kann die Isolation reduzieren und zu t dlichen Stromschl gen f hren Beim Einsatz von Nebelger ten ist zu beachten dass der Spot nie direkt dem Nebelstrahl ausgesetzt ist und mindestens 0 5 m von einem Nebelger t entfernt betrieben wird Der Raum darf nur so stark mit Nebel ges ttigt sein dass eine gute Sichtweite von mindestens 10 m besteht Die Umgebungstemperatur muss zwischen 5 C und 45 C liegen Halten Sie den Spot von direkter Sonneneinstrahlung auch beim Transport in geschlossenen W gen und Heizk rpern fern Die relative Luftfeuchte darf 50 bei einer Umgebungstemperatur von 45 C nicht berschreiten Dieser Spot darf nur in einer H henlage zwischen 20 und 2000 m ber NN betrieben werden Verwenden Sie den Spot nicht bei Gewitter berspannung k nnte den Spot zerst ren Der Spot bei Gewitter allpolig vom Netz trennen Netzstecker ziehen Das Bildzeichen m bezeichnet den Mindestabstand zu beleuchteten Gegenstanden Der Abstand zwischen Lichtaustritt und der zu beleuchteten Flache darf 0 5 Meter nicht unterschreiten Der Spot darf nur ber den Montageb gel installiert werden Um eine gute Luftzirkulation zu gew hrleisten muss um das Spot ein Freiraum von mindestens 50 cm eingehalten werden D
28. xposed to high humidity Also if the pinspot is still running the pinspot must be checked by a specialist if the liquid has reduced any insulation Reduced insulation can cause mortal electrical shock There must never be any objects entering into the pinspot This is especially valid for metal parts If any metal parts like staples or coarse metal chips enter into the pinspot the pinspot must be taken out of operation and disconnected immediately Malfunction or short circuits caused by metal parts may cause mortal injuries During the initial start up some smoke or smell may arise This is a normal process and does not necessarily mean that the Pinspot is defective Caution During the operation the housing becomes very hot Do not switch the Pinspot on and off in short intervals as this would reduce the lamp s life 11 16 00061369 DOC Version 2 1 HEALTH HAZARD AN Never look directly into the light source as sensitive persons may suffer an epileptic shock especially meant for epileptics Keep away children and amateurs Never leave this pinspot running unattended CAUTION Provide for sufficient splinter shield OPERATING DETERMINATIONS This spot is a lighting effect for creating decorative effects This product is only allowed to be operated with an alternating voltage of 230 V 50 Hz and was designed for indoor use only This spot is designed for professional use e g on stages in discotheques theatres etc L
Download Pdf Manuals
Related Search
Related Contents
Ficha de Dados de Segurança LIQUID BLUE – 500 M L Ferramenta de simulação da iluminação pública Tacens Anima AM1 DOS SUPERSCHNELL KLEBFIX ELASTOBOND Newsletter #56 - Le syndicat national des animaleries Owner`s/User`s Manual Photoshop Lightroom User Guide Betriebsanleitung FKL in_ES_PT 201508.pub Velleman KNS2 toy Bedienungsanleitung de Operating instructions en Mode d Copyright © All rights reserved.