ONYX-2122GS Manual_1st Ed
Contents
1. LAN Driver Step 4 Install Audio Driver Step 5 Install Touch Driver Optional Step 6 Install iAMT Driver Optional Please read instructions below for further detailed installations Chapter 4 Driver Installation 4 2 Medical Station ONYX 2122GS 4 1 Installation Insert the ONYX 2122GS CD ROM into the CD ROM drive And install the drivers from Step 1 to Step 6 in order Step 1 Install Intel INF Driver 1 Click on the Step 1 Inf Driver folder and double click on the infinst911autol exe 2 Follow the instructions that the window shows 3 The system will help you install the driver automatically Step 2 Install Intel VGA Driver 1 Click on the Step 2 VGA Driver folder and select the OS folder your system is 2 Double click on the exe file located in the OS folder 3 Follow the instructions that the window shows 4 The system will help you install the driver automatically Step 3 Install Intel LAN Driver 1 Click on the LAN driver folder and select the Winx32 folder and double click on exe for x86 32bit OS if the OS is Windows 64bit OS please select the Winx64 folder and double click on exe file 2 Follow the instructions that the window shows 3 The system will help you install the driver automatically Chapter 4 Driver Installation 4 3 Medical Station ONYX 2122GS Step 4 Install Audio Driver 1 Click on the Step 4 AUDIO driver folder and select the correspondin
2. 1 General Information 1 3 Emart Healthcare y AAEON Medical Station ONYX 2122GS 1 3 Specification Hardware Specifications Display 21 5 wide color TFT LCD Type System DDR3 SODIMM x 2 supports Up to 8GB Memory CPU Board Intel Core 2 Duo ULV 1 86GHz SL9400 Celeron M 1 2 GHz LV723 Drive Bay 2 5 Hard Disk Drive Expansion Internal Mini PCI Mini Card Button Brightness Sound Power SW 1 0 1x RS 232 422 485 1 x Isolated RS 232 10 x USB2 0 8 x external 1 for touch 1 for Mini card 1 x Isolated USB full speed 12MHz 2 x 3W speaker on back side 2 x Isolated Giga LAN RJ 45 connector 1 x Mic In 1 x Lin Out LCD Specifications Model Name ONYX 2122GS Display Type 21 5 color TFT LCD Max Resolution Full HD 1920 x 1080 Max Colors 16 7M Dot Size mm 0 248 x 0 248 Luminance cd m2 300 TYP Chapter 1 General Information 1 4 Emart Healthcare y AAEON Medical Station ONYX 2122GS Viewing Angle 170 H 160 V Contrast Ratio 1000 1 Brightness Control Yes Back Light MTBF 50 000 Hrs Note All ONYX s LCD products are manufactured with High precision technology However there are a small number of defective pixels in all LCD panels that are not able to change color This is a normal occurrence for all LCD displays from all manufacturers and should not be
3. System CMOS real time clock Microsoft ACPI Compliant System PS 2 Compatible Mouse Numeric data processor Intel R ICH9 Family SMBus Controller 2930 Intel R ICH9 Family PCI Express Root Port 1 2940 Intel R ICH9 Family USB Universal Host Controller 2937 Intel R Management Engine Interface Mobile Intel R 4 Series Chipset PCI Express Root Port 2A41 Mobile Intel R 4 Series Express Chipset Family Intel R Active Management Technology SOL COM3 Intel R Gigabit CT Desktop Adapter Intel R ICH9 Family PCI Express Root Port 2 2942 Intel R ICH9 Family PCI Express Root Port 3 2944 Intel R ICH9 Family USB Universal Host Controller 2936 Intel R ICH9 Family USB2 Enhanced Host Controller 293C Standard Dual Channel PCI IDE Controller Intel R ICH9 Family PCI Express Root Port 4 2946 Intel R ICH9 Family USB Universal Host Controller 2939 Intel R ICH9 Family USB Universal Host Controller 2935 Intel R ICH9M M E 2 port Serial ATA Storage Controller 1 2928 Intel R ICH9M M E 2 port Serial ATA Storage Controller 2 292D Intel R 82567LM Gigabit Network Connection Intel R ICH9 Family USB Universal Host Controller 2938 Microsoft UAA Bus Driver For High Definition Audio Intel R ICH9 Family USB Universal Host Controller 2934 Intel R ICH9 Family USB2 Enhanced Host Controller 2934 Appendix B I O Information B 4 Emart Healthcare y AAEON Medical Station ONYX 2122GS B 4 DMA Channel Assignments M
4. before touching the board ag e X Modern electronic devices are very sensitive to static electric charges please remember to use a grounding wrist strap at all times e Place all electronic components on a static dissipative surface or in a static shielded bag when they are not in the chassis Chapter 2 Hardware Installation 2 2 Smart Hoaithcaro y AAEON Medical Station ONYX 2122GS 2 2 A Quick Tour of the ONYX 2122GS Before you start to set up the ONYX 2122GS take a moment to become familiar with the locations and purposes of the controls drives connections and ports which are illustrated in the figures below When you place the ONYX 2122GS upright on the desktop its front panel appears as shown in Picture 2 1 Die Picture 2 1 Front View of the Medical Station When you turn the Medical Station around and look at its rear cover the sunken I O section is at the bottom of the station as shown in Picture 2 2 The I O section includes various I O ports including DC in COM ports Ethernet DVI USB The medical Station integrates with WLAN function by using Mini PCI Chapter 2 Hardware Installation 2 3 Smart Hosttica ro y AAEON Medical Station ONYX 2122GS 4x USB Isolated USB 4 x USB 2x Isolated LAN VI Isolated COM COM DC 9V 30V Line Out Mic In Figure 2 2 Rear view of the Medical Station Chapter 2 Hardware Installation 2 4 Smart Healthes ro y AAEON Medical Station ONYX 21
5. 002 5692 DA Son The Netherlands Tel 31 0 499 462020 Fax 31 0 499 462010 E mail eusales onyx healthcare com Onyx Healthcare Technology GmbH An der Trift65d 63303 Dreieich Germany TEL 49 0 61033 7479 00 Fax 449 0 61033 7479 49 E mail eusales onyx healthcare com Onyx Healthcare Technology Nanjing Inc Room 1318 Metallurgy Building East Zhongshan Road Nanjing China Tel 86 025 58859841 Fax 86 025 85088078 E mail Jonwang onyx healthcare com Medical Station ONYX 2122GS Onyx Healthcare Singapore PTE LTD 57 Genting Lane 07 00 Singapore 349564 Tel 65 67498749 Fax 65 67461595 Email sgsales onyx healthcare com Medical Station ONYX 2122GS Safety amp Warranty 1 Read these safety instructions carefully 2 Keep this user s manual for later reference 3 Disconnect this equipment from any AC outlet before cleaning Do not use liquid or spray detergents for cleaning Use a damp cloth 4 For pluggable equipment the power outlet must be installed near the equipment and must be easily accessible 5 Keep this equipment away from humidity 6 Putthis equipment on a reliable surface during installation Dropping it or letting it fall could cause damage 7 The openings on the enclosure are for air convection Protect the equipment from overheating DO NOT COVER THE OPENINGS 8 Make sure the voltage of the power source is correct before connecting the equipment to the power outle
6. 22GS 2 3 VESA Mounting Holes Onyx 2122GS is suitable for VESA75 100mm interface pads for desktop stand VESA Screws M4 x 0 7 x 20mm m DIET mu Nm E E a Ill qu i e NN TNT il i 100 00 ONYX 2122GS Chapter 2 Hardware Installation 2 5 Smart Hoaithcaro y AAEON Medical Station ONYX 2122GS Chapter Award BIOS Setup Chapter 3 Award BIOS Setup 3 1 Medical Station ONYX 2122GS 3 1 System Test and Initialization These routines test and initialize board hardware If the routines encounter an error during the tests you will either hear a few short beeps or see an error message on the screen There are two kinds of errors fatal and non fatal The system can usually continue the boot up sequence with non fatal errors Non fatal error messages usually appear on the screen along with the following instructions Press lt F1 gt to RESUME Write down the message and press the F1 key to continue the boot up sequence System configuration verification These routines check the current system configuration against the values stored in the CMOS memory If they do not match the program outputs an error message You will then need to run the BIOS setup program to set the configuration information in memory There are three situations in which you will need to change the CMOS settings 1 You are starting your system for the first time 2 You have
7. GS Contents Chapter 1 General Information 1 1 Introduetion ssn a iia 1 2 JU atu T 1 3 1 9 Specification sd nad a 1 4 1 4 DIMENSION a 1 8 Chapter 2 Hardware Installation 2 1 Safety Precautions raras 2 2 2 2 A Quick Tour of the ONYX 2122GS 2 3 2 3 VESA Mounting Holes pp 2 5 Chapter 3 Award BIOS Setup 3 1 System Test and Initialization sessssses 3 2 3 2 Award BIOS Setyup ii 3 3 Chapter 4 Driver Installation 4 1 Installation 0 4 3 Appendix A I O Information A 1 1 0 Address Map seen A 2 A 2 Memory Address Map nein uer nur Lnnnuo A 2 A 3 IRQ Mapping Chart A 3 A 4 DMA Channel Assignments sess A 5 Appendix B Miscellanea B 1 General Cleaning Tips B 2 Medical Station ONYX 2122GS B 2 Cleaning TOOIS e B 3 B 3 Scrap Computer Recycling ee B 5 Medical Station ONYX 2122GS Chapter General Information Chapter 1 General Information 1 1 Medical Station ONYX 2122GS 1 1 Introduction The ONYX 2122GS is a Slim Medical Panel PC with Intel Core 2 Duo ULV processor based computer that is designed to serve as a point of care station It is a PC based system with 21 5 true color TFT LCD display Zero Noise solution integrated multimedia functions make them the perfect platforms to build comprehensive lifestyle computing applications The ONYX 2122GS inc
8. Medical Station ONYX 2122GS ONYX 2122GS 21 5 Intel Core 2 Duo Processor LCD display COM USB Isolation Fanless Slim Medical Panel PC ONYX 2122GS Manual 1 Edition April 2011 Medical Station ONYX 2122GS Copyright Notice This document is copyrighted 2011 All rights are reserved The original manufacturer reserves the right to make improvements to the products described in this manual at any time without notice No part of this manual may be reproduced copied translated or transmitted in any form or by any means without the prior written permission of the original manufacturer Information provided in this manual is intended to be accurate and reliable However the original manufacturer assumes no responsibility for its use nor for any infringements upon the rights of third parties which may result from its use The material in this document is for product information only and is subject to change without notice While reasonable efforts have been made in the preparation of this document to assure its accuracy ONYX Healthcare Inc assumes no liabilities resulting from errors or omissions in this document or from the use of the information contained herein ONYX Healthcare Inc reserves the right to make changes in the product design without notice to its users Medical Station ONYX 2122GS Acknowledgments e Intel Core Duo are registered trademarks of Intel Corporation e IBM PC AT P
9. S 2 are trademarks of International Business Machines Corporation e Microsoft Windows is a registered trademark of Microsoft Corporation e RTL is a trademark of Realtek Semi Conductor Co Ltd e C amp T is a trademark of Chips and Technologies Inc e UMC is a trademark of United Microelectronics Corporation e ITE is a trademark of Integrated Technology Express Inc All other product names or trademarks are properties of their respective owners Medical Station ONYX 2122GS Packing List Before you begin installing your Bedside Terminal please make sure that the following items have been shipped m ONYX 2122GS Medical Station m HDD Screws VESA Screws M4 x 0 7 x 20mm m Utility CD ROM Please insert the ONYX 2122GS CD ROM into external CD ROM drive which Contains User s Manual in PDF format Drivers and Utilities If any of these items are missing or damaged you should contact your distributor or sales representative immediately Headquarters Onyx Healthcare Inc 2F No 135 Lane 235 Pao Chiao Rd Hsin Tien City Taipei 231 Taiwan R O C TEL 886 2 8919 2188 FAX 886 2 8919 1699 E mail sales onyx healthcare com http www onyx healthcare com Medical Station ONYX 2122GS Worldwide Offices Onyx Healthcare USA Inc 2663 Saturn street Brea CA 92821 USA Tel 1 714 996 1800 Fax 41 714 996 1811 E mail usasales onyx healthcare com Onyx Healthcare EUROPE B V Ekkersrijt 4
10. changed the hardware attached to your system 3 The CMOS memory has lost power and the configuration information has been erased The ONYX 2122GS CMOS memory has an integral lithium battery backup for data retention However you will need to replace the complete unit when it finally runs down Chapter 3 Award BIOS Setup 3 2 Medical Station ONYX 2122GS 3 2 Award BIOS Setup Awards BIOS ROM has a built in Setup program that allows users to modify the basic system configuration This type of information is stored in battery backed CMOS RAM so that it retains the Setup information when the power is turned off Entering setup Power on the computer and press lt Del gt immediately This will allow you to enter Setup Standard CMOS Features Use this menu for basic system configuration Date time IDE etc Advanced BIOS Features Use this menu to set the advanced features available on your system Advanced Chipset Features Use this menu to change the values in the chipset registers and optimize your system performance Integrated Peripherals Use this menu to specify your settings for integrated peripherals Primary slave secondary slave keyboard mouse etc Power Management Setup Use this menu to specify your settings for power management HDD power down power on by ring etc Chapter 3 Award BIOS Setup 3 3 Medical Station ONYX 2122GS PnP PCI Configurations This entry appears if your sy
11. g folder for your operating system and double click on Setup exe file 2 Follow the instructions that the window shows 3 The system will help you install the driver automatically Step 5 Install Touch Panel Driver 1 Click on the Touch folder Optional and and select the PenMount Windows Universal Driver V2 2 0 283 folder and double click on the setup exe Follow the instructions that the window shows The system will help you install the driver automatically Step 6 Install iAMT Driver 1 Click on the iAMT folder Optional and select the LMS SOL folder and double click on the setup exe 2 Click on the iAMT folder and select the MEI folder and double click on the setup exe Follow the instructions that the window shows The system will help you install the driver automatically Chapter 4 Driver Installation 4 4 Medical Station ONYX 2122GS Notes A When you need to have iAMT function you have to set iAMT as Enable in BIOS setup menu B When system enters into S3 mode which iAMT function disable user continues to knock machine twice system will wake up Otherwise when the machine encounters to continuous vibration period of time simulate machines to install in the cart the cart pass through continuous lame road the system will enter the S3 sleep mode to protect hard disk function Chapter 4 Driver Installation 4 5 Medical Station ONYX 2122GS Appendix I O Information Appendix B I O Informat
12. il Direct memory access DMA g_4_ Direct memory access controller Appendix B I O Information B 5 Medical Station ONYX 2122GS Appendix Miscellanea Appendix C Miscellanea C 1 Medical Station ONYX 2122GS C 1 General Cleaning Tips You may need the following precautions before you begin to clean the computer When you clean any single part or component for the computer please read and understand the details below fully 1 Neversprayor squirt the liquids directly onto any computer component If you need to clean the device please rub it with a piece of dry cloth 2 Be cautious of the tiny removable components when you use a vacuum cleaner to absorb the dirt on the floor 3 Turn the system off before you start to clean up the component or computer 4 Never drop the components inside the computer or get circuit board damp or wet 5 Be cautious of all kinds of cleaning solvents or chemicals when you use it for the sake of cleaning Some individuals may be allergic to the ingredients 6 Try not to put any food drink or cigarette around the computer Appendix C Miscellanea C 2 Medical Station ONYX 2122GS C 2 Cleaning tools Although many companies have created products to help improve the process of cleaning your computer and peripherals users can also use household items to clean their computers and peripherals Below is a listing of items you may need or want to use while cleaning you
13. ion B 2 Medical Station ONYX 2122GS B 1 1 0 Address Map Ml Input output IO Y 00000000 00000CF7 PCI bus X 00000000 DODOFFFF PCI bus Appendix B I O Information B 2 Medical Station ONYX 2122GS B 2 Memory Address Map MN Memory 4 00000000 0009FFFF System board X 00040000 ODOBFFFF PCI bus 000C0000 ODODFFFF PCI bus 000E0000 OOOEFFFF System board 000F0000 ODOFFFFF System board 00100000 TACSFFFF System board 7AC90000 7ACFFFFF System board 74D00000 FEBFFFFF PCI bus 4 E 4 3 3 4 FEC00000 FECODFFF System board 4 4 E 4 4 FED13000 FED1FFFF System board FED20000 FED9FFFF System board FEEODDDD FEEODFFF System board FFB00000 FFB7FFFF System board FFB80000 FFBFFFFF Intel R 82802 Firmware Hub Device FFF00000 FFFFFFFF System board Appendix B I O Information B 3 Medical Station ONYX 2122GS B 3 IRQ Mapping Chart BN Interrupt request IRO y asa o y SA 1 Y 54 3 3 5A 4 asa 8 W ISA 9 15 asa 12 ISA 13 PCI 11 PCI 16 PCI 16 PCI 16 PCI 16 PCI 16 Y PCI 17 PCI 17 3 3 i T d PCI 17 PCI 18 PCI 18 PCI 18 PCI 18 PCI 19 PCI 19 PCI 19 B PCI 19 S PCI 19 Eg PCI 20 amp PCI 21 PCI 22 PCI 23 PCI 23 System timer Standard 101 102 Key or Microsoft Natural PS 2 Keyboard Communications Port COM2 Communications Port COM1
14. ludes all the features of a powerful computer into a slim and attractive chassis The ONYX 2122GS has 300 nits TFT displays with Full HD 1920 x 1080 resolution Integrating with high brightness LCD is easier to analyze DICOM images It supports 2 5 Hard Disk Drive storage function and one Mini PCI for WLAN expansion Moreover they feature flexible I O ports such as eight USB2 0 one Isolated USB one Isolated RS 232 one RS 232 422 485 two Isolated Gigabit LAN one DVI one Line Out and one Mic In Convenient operation Silent compact mobility and highly integrated multimedia system let you to focus on healthcare utility interactive information displays automation control systems general desktop usage multimedia recreation and other medical requirements Chapter 1 General Information 1 2 Emart Healthcare y AAEON Medical Station ONYX 2122GS Note Customers must be noted that storage media shall be bundled and purchased together with ONYX 2122GS while it is shipped out 1 2 Feature e Intel Core 2 Duo Processor Celeron Mobile Processor e 21 5 Full HD Resolution LCD e Easy To Use Compact Simple Design e Fanless Zero Noise e 300 nits high brightness 1000 1 contrast to X ray films e 1 COMs 1 USB Isolation Optional e 5 Wire Resistive Touchscreen Optional e Mini PCI 802 11a b g n Wireless Antenna internal Optional e CE FCC Class B EN UL60601 1 Medical Certification Chapter
15. noticeable or objectionable under normal operation ONYX LCD panels are gualified for industry standard conditions in the following total 7 dead pixels on a screen or if there are 3 within 1 inch sguare area of each other on the display Mechanical Specifications Architecture Close frame Front Bezel Plastic bezel with resistive touch screen Color White Mounting Holder VESA 75 100mm Construction 3mm ABS PC TYPE Plastic housing Dimension 21 5 x 13 8 x 2 8 546mm x 351 4mm x 70mm W x H x D Carton Dimension 29 5 x 10 2 x 21 7 750mm x 260mm x 550mm Net Weight 15 2 Ib 6 9 kg Gross Weight 19 8 Ib 9 0 kg Chapter 1 General Information 1 5 Smart Healthcare y AAEON Medical Station ONYX 2122GS Packing Filler Power Supply Specifications Model Item PROTEK Power PMP90 14 B16 Power Requirement DC 9 30V Input Voltage 100 240V AC O 47 63Hz 1 06 0 45A Output Voltage 24V 3 75A 90W Max MTBF 100 000 hrs operation at 25 C Environmental Specifications Operating Temperature 0 C to 35 C Operating Humidity 30 75 Operating Atmospheric Pressure 850 1000hpa Storage Temperature 20 C to 60 C 4 F 140 F Storage Humidity 5 to 95 40 C non condensing Storage Atmospheric Pressure 850 1000hpa Vibration 0 5G 5 500Hz Random ope
16. plying with UL 60601 1 shall be kept outside environment as defined in the standard Caution lt may cause the danger of explosion if battery is incorrectly replaced Replace only with same or equivalent type recommended by the manufacturer Medical Station ONYX 2122GS 17 Unplug the power cord from the power adapter jack to disconnect the device Medical Station ONYX 2122GS Classification 1 Degreeof production against electric shock not classified 2 Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide Mode of operation Continuous Type of protection against electric shock Class equipment Class I No Applied part No AP APG Medical Station ONYX 2122GS FCC Warning This device complies with Part 15 FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Medical Station ONYX 2122GS UL Module Description o SI He OL Onyx 2122GS AC modules are developed to suitable for the Classification Mark requirement Medical Station ONYX 2122GS Safety Symbol Description The following safety symbols are the further explanations for your reference stia Medical equipment with respect to electric cydym shock fi
17. r computer or computer peripherals Keep in mind that some components in your computer may only be able to be cleaned using a product designed for cleaning that component if this is the case it will be mentioned in the cleaning tips e Cloth A piece of cloth is the best tool to use when rubbing up a component Although paper towels or tissues can be used on most hardware as well we still recommend you to rub it with a piece of cloth e Water or rubbing alcohol You may moisten a piece of cloth a bit with some water or rubbing alcohol and rub it on the computer Unknown solvents may be harmful to the plastics parts e Vacuum cleaner Absorb the dust dirt hair cigarette particles and other particles out of a computer can be one of the best methods of cleaning a computer Over time these items can restrict the airflow in a computer and cause circuitry to corrode Appendix C Miscellanea C 3 Medical Station ONYX 2122GS e Cotton swabs Cotton swaps moistened with rubbing alcohol or water are excellent tools for wiping hard to reach areas in your keyboard mouse and other locations e Foam swabs Whenever possible it is better to use lint free swabs such as foam swabs Note We strongly recommended that you should shut down the system before you start to clean any single components Please follow the steps below d 2 3 4 bi Close all application programs Close operating software Turn off po
18. ration Shock 20G peak acceleration 11 msec duration operation Drop 76cm 1 Corner 3 Edge 6 Surface EMI Safety CE FCC Class B UL 60601 1 EN 60601 1 2006 Noise Zero noise Chapter 1 General Information 1 6 Smart Healthcare y AAEON Medical Station ONYX 2122GS Input Power Rating 100 240V 47 63Hz 1 06 0 45A TouchScreen Optional Type 5 wire Analog Resistive Interface USB Interface Resolution 2048 x 2048 Light Transmission gt 80 2 Life Time 35 million times Chapter 1 General Information 1 7 Medical Station ONYX 2122GS 1 4 Dimension ONYX 2122GS Chapter 1 General Information 1 8 Smart Healthcare y AAEON Medical Station ONYX 2122GS sini alll Im E oo E BUE it CE E Chapter 1 General Information 1 9 Medical Station ONYX 2122GS Chapter Hardware Installation Chapter 2 Hardware Installation 2 1 Smart Healthesre y AAEON Medical Station ONYX 2122GS 2 1 Safety Precautions Warning Always completely disconnect the power cord from your board whenever you are working on it e Donot make connections while the power is on because a sudden rush of power can damage sensitive electronic components Caution e Always ground yourself to remove any static charge
19. re and mechanical hazards only in accordance with UL 60601 1 and CAN CSA C22 2 NO 601 1 Attention consult ACCOMPANYING DOCUMENTS o US TE Ground wire Protective Ground wire Medical eguipment with respect to electric ta shock fire and mechanical hazards only in C US accordance with UL 60601 1 and CAN CSA C22 2 NO 601 1 Medical Station ONYX 2122GS Below Table for China RoHS Requirements Onyx Panel PC Workstation 6 ze i RAR Pb Hg Cd Cr VI PBB PBDE x o o o o o x o o o o o Ne x o o o o o x o o o o o HE EET HERE x o o o o o X O O O O O x o o O O O MPAA x o O O o O x o o o o o O ENA BA ED IS AI ISTE SJ T 11363 2006 X SJ T 11363 2006 fist Z ERAMA HRA aO gt BERR OGER ATERIA RER Medical Station ONYX 2122
20. stem supports PnP PCI PC Health Status This menu shows you the status of PC Frequency Voltage Control This menu shows you the display of freguency Voltage Control Load Fail Safe Defaults Use this menu to load the BIOS default values for the minimal stable performance for your system to operate Load Optimized Defaults Use this menu to load the BIOS default values that are factory settings for optimal performance system operations While AWARD has designated the custom BIOS to maximize performance the factory has the right to change these defaults to meet their needs Set Supervisor User Password Use this menu to set Supervisor User Passwords Save and Exit Setup Save CMOS value changes to CMOS and exit setup Exit Without Saving Abandon all CMOS value changes and exit setup Chapter 3 Award BIOS Setup 3 4 Medical Station ONYX 2122GS Chapter Driver Installation Chapter 4 Driver Installation 4 1 Emart Healthcare yx Medical Station ONYX 2122GS The ONYX 2122GS comes with an AutoRun CD ROM that contains all drivers and utilities that can help you to install the driver automatically Insert the driver CD the driver CD title will auto start and show the installation guide If not please follow the sequence below to install the drivers Follow the sequence below to install the drivers Step 1 Install Intel INF Driver Step 2 Install Intel VGA Driver Step 3 Install Intel
21. t 9 Position the power cord so that people cannot step on it Do not place anything over the power cord 10 All cautions and warnings on the equipment should be noted 11 If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient over voltage 12 Never pour any liquid into an opening This could cause fire or electrical shock 13 Never open the equipment For safety reasons only qualified service personnel should open the equipment Medical Station ONYX 2122GS 14 If any of the following situations arises get the equipment checked by service personnel a The power cord or plug is damaged b Liquid has penetrated into the equipment c The equipment has been exposed to moisture d The equipment does not work well or you cannot get it to work according to the user s manual e The equipment has been dropped and damaged f The equipment has obvious signs of breakage 15 DO NOT LEAVE THIS EQUIPMENT IN AN UNCONTROLLED ENVIRONMENT WHERE THE STORAGE TEMPERATURE IS BELOW 20 C 4 F OR ABOVE 60 C 140 F IT MAY DAMAGE THE EQUIPMENT 16 External equipment intended for connection to signal input output or other connectors shall comply with relevant UL IEC standard e g UL 1950 for IT equipment and UL 60601 1 IEC 60601 series for systems shall comply with the standard IEC 60601 1 1 Safety requirements for medical electrical systems Equipment not com
22. wer switch Remove all device Pull out power cable Appendix C Miscellanea C 4 Medical Station ONYX 2122GS C 3 Scrap Computer Recycling If the computer equipments need the maintenance or are beyond repair we strongly recommended that you should inform us as soon as possible for the suitable solution For the computers that are no longer useful or work well please contact with worldwide distributors for recycling The worldwide distributors show on the following website http www onyx healthcare com tw Contact php Note Follow the national requirements to dispose unit Appendix C Miscellanea C 5