Home

Installation & Operation Manual

image

Contents

1. strobe alarm of the home security device This siren is a Z Wave enabled device interoperable two way RF mesh networking 1 Remove the bracket from the siren by press the locking tab and then gently slide technology and is fully compatible with any Z Wave enabled network Every main up the siren Observe the correct polarity before insert the batteries powered Z Wave enabled device acts as a signal repeater and multiple devices result in 2 Using the screws or adhesive tape to affix the bracket on the chosen location more possible transmission routes which helps eliminate RF dead sports 3 Slide back the cover and screw fastening with the front cover the LED should go off Z Wave enabled devices displaying the Z Wave logo can also be used with it regardless of the manufacturer and ours can also be used in other manufacturer s Z Wave enabled networks This product will sound a loud siren and flash a strobe light when an alarm message or alert is received on any Z Wave enabled network Use Screws or Adhesive Tape Product Description and Specification For indoor use only For Inclusion in adding to a network Put the Z Wave Interface Controller into inclusion mode and following its instruction to add the ZM 1601 to your controller To get in the inclusion mode the distance between siren and controller is Suggested to be in one meter Open the bracket and press the program sw
2. Federal Communications Commission Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction may cause harmful interference to radio communications However there is no guarantee that interference will not occur ina particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try and correct the interferene by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into and outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undersired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for com
3. itch of ZM 1601 for 1 second at least amp release to be included After setting the LED Switch Setting Lighting should go off if not please try again LED setting light LED Strobe Lighting Locking Tab For Exclusion from removing from a network Set up the Z Wave Interface Controller into exclusion mode and following its instruction to delete the ZM 1601 Specification Package Content from your controller Press the program switch of ZM 1601 for 1 second at least amp 7 T release to be excluded ice ia ZM3102N 1pc ZM kag Siren Note LED setting light will flash orange color continuously in Exclusion condition tpc Adhesive tape 5 Configuration command class 868 42MHz ZM1602EU 2pcs Screw Parameter 0 Siren Strobe Mode 1 Byte Value 0 siren and Strobe enable 908 42MHz ZM1602US 921 42MHz ZM1602AU default 1 siren only 2 Strobe only Spee ARE Neier BAUGE Parameter 1 Alarm auto stop time command 0 30 seconds default 1 60 secs Operating Range Up to 100 feet line of sight 1pc Aa amp Operation 2 120 secs 3 siren will not automatically stop Loud Audible Alarm gt 105Db 1 meter aie LED Strobe Lighting Operation ea ae a z aad F 1 Normal operation the LED light will not on ai Perge Panes 2 Self Protection Mode After put back the bracket over 5 seconds ZM 1601 will enter Self Protection Mode If the back cover is opened will trigger the Self Protection Mode The alarm time i
4. pliance could void the user s authority to operate this equipment Limited Warranty Vision Guarantees that every wireless siren amp strobe alarm is free from physical defects in material and workmanship under normal use for one year from the date of purchase If the product proves defective during this one year warranty period Vision will replace it free of charge Vision does not issue any refunds This warranty is extended to the Original end user purchase only and is not transferable This warranty does not apply to 1 damage to units caused by accident dropping or abuse in handling or any negligent use 2 units which have been subject to unauthorized repair taken apart or otherwise modified 3 units not used in accordance with instruction 4 damages exceeding the cost of the product 5 transit damage initial installation costs removal cost or reinstallation cost For information on addional devices plesae visit us at www visionsecurity com tw ZM 1601 1001227 6B1Z 16001 The Ultimate in Security amp Automation Installation amp Operation Manual ZM 1601 EU ZM 1601 US ZM 1601 AU Wireless Siren amp Strobe Alarm Battery Power Installation Note If you are installing the entire Z Wave system for the first time please refer to the installation guide of Z Wave Interface Controller before installing ZM 1601 Introduction Thanks for choosing the Vision s wireless siren amp
5. s default 30 seconds 3 User s controller should support Z wave FLIRS technology 4 Alarm Mode It s the status of alarm triggered It s based on the user s configuration setting of LED flash ON OFF and Siren ON OFF Note for Default setting Siren Strobe Mode Parameter will be All enable Alarm Auto Stop Time Parameter will be 30 sec 5 For safety reason replace new battery whenever ZM 1601 is triggered aD

Download Pdf Manuals

image

Related Search

Related Contents

M8128 User`s Manual - Sunrise Instruments  Service Service Service  Manual placa GA-8SDX  Consignes Mode d`emploi - Territoire des Alpes Maritimes  User manual / Bedienungsanleitung / Инструкция по    Fujitsu fi-6400  USER MANUAL Made in the USA!  User manual  User Manual for the Gigabit Ethernet Adapter  

Copyright © All rights reserved.
Failed to retrieve file