Home
MultiBio700 User Manual
Contents
1. Display the Numb Bit Counts 0 Cancel Input Backspace Confirm Input Clear Input Characters used to define data bits and their meanings c Indicates the card number that is the output contents it can be set to User ID Card Number through menu operations f Indicates the facility code which is O by default Itis not Md configurable To modify it please contact the equipment supplier m Indicates the manufacturer code which is 0 by default It is not configurable To modify it please contact the equipment supplier p Indicates the parity position s Indicates the site code which can be set from 0 to 255 by default 47 MultiBio700 User Manual 1 0 4 Click the entry box below Parity Format to display the following interface Characters used to define parity bits and their meanings o Indicates the odd check that is there is an odd number of 1 s in the bit sequence including one parity bit For example for 1000110 0 the parity bit is O and there are already three 1 s After O is suffixed to 1000110 there is still an odd number of 1 s e Indicates the even check that is there is an even number of 1 s in the bit sequence including one parity bit For example for 1000110 1 the parity bit is 1 and there are already three 1 s After 1 is suffixed to 1000110 there is an even number of 1 s b Indicates both odd check and even check For example Definitions of several
2. Group No 1 as shown in the figure Hole User Photo User Access yacancy wacant a au e ele ETIE Add User tom Fingerprint Password gt Face Group No 1 DKeyboard Area 2 Text Display Area 3 Text List Area 4 Exit G Delete Enter Space Q Character English Upper Lower Case 84 Error Use the Home tab to apply tx 1 to the text that you want to appear here To enter a name proceed as follows 1 Press Name on the Add interface as shown in Figure below 2 Enter the letter characters and a list of characters in relation to the letter is presented in the text display area 3 If the desired character is displayed in the text display area press this character And this character is at the same time displayed on the Name button Enter next character by repeating Step 2 4 After finishing the entry of name press X to exit keyboard interface and return to the previous interface Add User Add User Add User Fingerprint a Password O as Face gt Face Group No 1 Group No 1 Group No 1 f h Role User Photo f User Access Taser aABB0ODO EJEA sace EN 85 MultiBio700 User Manual 1 0 Appendix 2 Introduction of Wiegand Wiegand26 is an access control standard protocol established by the Access Control Standard Subcommittee affiliated to the Security Industry Association SIA It is a non contact IC card reader inter
3. are the site code the 21 to the 36 bits are the card number Wiegand50 Data bits pssssssssssssssssccccccccccccccccccccccccccccccccp Parity bits eeeeeeeeeeeeeeeeeeeeeEEEEO0000000000000000000000000 Note Wiegand50 consists of 50 bits The first bit is the even parity bit of bits 2 to 25 the 50 bit is the odd parity bit of bits 26 to 49 the second to the 16 bits are the site code the 17 to the 49 bits are the card number 49 MultiBio700 User Manual 1 0 5 3 Wiegand Input Wiegand Format The system has two built in formats Wiegand 26 bits and Wiegand 34 bits and also supports the format customization function to meet individualized requirements About the Wiegand format please refer to 5 2 Wiegand Output Bit counts Wiegand data digit length Pulse width Pulse width is 100 microseconds by default which can be adjusted from 20 to 800 Pulse interval lt is 900 microseconds by default which can adjusted between 200 and 20000 Input Content contained in Wiegand input signal including User ID or card number Wiegand Input Wiegand 26 Define Bit Counts 26 Pulse Width us 100 Pulse Interval us 1000 a Input gt User ID lt Exit Save 50 Error Use the Home tab to apply 7 1 to the text that you want to appear here 6 System Configuration Through the System menu you can set system related parameters including the General Display Fingerprint Face Log settings
4. 42 Error Use the Home tab to apply jx 1 to the text that you want to appear here successful verification d 1100110000100011110100000 Even parity bit User ID Binary code of 0013378512 Odd parity bit 3 The Wiegand output is as follows upon verification failure 000000000000000 00000000010 Even parity bit Failed ID Binary code of 1 Odd parity bit 42 Note If the output contents exceed the scope allowed for the Wiegand format the last several bits will be adopted and first several bits are automatically discarded For example the user ID 888 888 888 is 110 100 111 110 110 101 111 000 111 000 in binary format Wiegand26 only supports 24 bits that is it only outputs the last 24 bits and first 6 bits 110 100 are automatically discarded 43 MultiBio700 User Manual 1 0 5 2 2 Wiegand 34 bits Output Description The system has a built in Wiegand 34 bits format Press Wiegand Format and select Standard Wiegand 34 bits The composition of the Wiegand 34 bits format contains 2 parity bits and 32 bits for output contents User ID or Card Number The binary code of 32 bits represent up to 4 294 967 296 0 4 294 967 295 different values 1 2 33 34 User ID Card Number Odd parity bit Table 2 Definition of Fields Even parity bit Judged from bit 2 to bit 17 The even parity bit is 1 if the character has an even number of 1 bits otherwise the even parity bit is 1 User ID Card User ID Card
5. Valid in Holiday KC Exit g N a a inconsistent with the normal state set by the door sensor switch an alarm will be generated and this period of time 10 10 30 3 0 0 Save is regarded as the door sensor delay Value scope 1 99 seconds Door Sensor Mode includes the None Normally Open NO and Normally Closed NC modes None indicates that the door sensor switch is not used NO indicates that the door sensor is open in the normal state NC indicates that the door sensor is closed in the normal state Alarm Delay indicates the duration from the detection of door sensor exceptions to the generation of alarm signals Value scope 1 99 seconds Failure Alarm Threshold When the failed press times reach the set times alarm signal will come out effective value 1 9 times NC Time Zone Set time zone for access control NC Nobody can unlock during this time zone NO Time Zone Set time zone for access control NO The lock is always in enabling state during this time zone Valid in Holiday Define time zone for NO or NC Whether the time zone set in time zone is effective Notice 1 When time zone is set for NO or NC please set door sensor mode as None or alarm signal may come out during time zone of NO or NC 69 MultiBio700 User Manual 1 0 42 Notice 1 If the Time Zone of normally open or normally closed has been set please switch door sensor to no otherw
6. to save or press X to cancel Group No 1 and return to the previous SS h Role User interface r Photo User Access 2 Enter Text Press the Name Add User key The system automatically MI fl lnnnncnnnna displays the text input interface i J g tom After entering the user name Fingerprint O Fingerprint password press X to save and return to i a Face CS the previous interface E Group ost MultiBio700 User Manual 1 0 3 Modify parameters Press the default value of a parameter and the system automatically switches to another value of this parameter General Keyboard Clicks gt DON Voice Prompts gt Ml Volume Lock Power Key a General Keyboard Clicks N Volume Lock Power Key Error Use the Home tab to apply 7 1 to the text that you want to appear here 1 6 Appearance of Device 1 Front View Indicator Touch Screen Touch keys Camera Push Buttons Fingerprint Sensor ID Card Swipe Area 2 Side View Reset Button USB Port MultiBio700 User Manual 1 0 1 7 Main Interface Date 10 10 12 EH D Screen Shortcut Time Attendance Status Face Image 1 1 Switch Key Menu A Ju gt 1 1 Switch button Door Bell Date Current date is displayed Screen Shortcut Keys Press this shortcut keys to display the attendance status and enter the functional interface quickly Users ca
7. 20 Error Use the Home tab to apply 7 1 to the text that you want to appear here 3 2 Entering a Name Use T9 input method to enter the user name through the keyboard 1 Press Name on the Add User interface to display the name input interface 2 On the displayed keyboard interface enter a user name and press X For details of operations on keyboard interface see Appendix 1 T9 Input Instructions 3 After the user name is entered press Save to save current information and return to the previous interface Press Exit to return to the previous interface without saving current information Add User tom Fingerprint Password gt Face Group No 1 Add User Fingerprint Password Face Add User Group No Role User Photo User Access Group No 1 b Role User Photo User ccess BS Tip The device supports the 1 to 12 characters names by default 21 MultiBio700 User Manual 1 0 3 3 Enrolling a Fingerprint 1 Press Fingerprint on the Add User interface to Add User display the Enroll Fingerprint interface 2 On the displayed Enroll Fingerprint interface place p your finger on the fingerprint collector properly Sa se according to the system prompt For details see 1 3 Finger Placement 3 Place the same finger on the fingerprint collector for three consecutive times correctly If the enrollment m oto succeeds the system will display
8. Number Card Code 0 4 294 967 295 Number bit 2 bit 33 Bit 2 is the Most Significant Bit MSB Odd parity bit Judged from bit 18 to bit 33 The odd parity bit is 1 if the character has an even number of 1 bits otherwise the odd parity bit is O For example for a user with user ID of 123456789 the enrolled card number is 0013378512 and the failed ID is set to 1 1 When the output is set to User ID the Wiegand output is as follows upon successful verification 0000001110101101111001101000101011 Even parity bit User ID Binary code of 123456789 Odd parity bit 44 Error Use the Home tab to apply jx 1 to the text that you want to appear here 2 When the output is set to Card Number the Wiegand output is as follows upon successful verification 0000000001100110000100011110100001 Even parity bit User ID Binary code of 0013378512 Odd parity bit 3 The Wiegand output is as follows upon verification failure 0000000000000000000000000000000010 Even parity bit Failed ID Binary code of 1 Odd parity bit 45 MultiBio700 User Manual 1 0 5 2 3 Customized Format Apart from the two built in formats Wiegand 26 bits and Wiegand 34 bits the system also supports the format customization function to meet individualized requirements The customized format consists of two character strings the data bits and parity bits These two character strings need to be defined separately Data bits define the number of
9. PC including the IP address gateway subnet mask baud rate equipment ID and communication password E gt lt Auto Test lt Exit N Data Mgt P e Dn Upload Date Time 2 A Sys Info Communication Network Serial Port Settings Wiegand Input Wiegand Output Network Serial Port Settings IP Address 192 168 8 182 Subnet Mask 255 255 255 0 Gateway 192 168 8 254 RS232 b OFF RS485 b ON Baud Rate 115200 Device ID Comm Key 1 0 38 Error Use the Home tab to apply jx 1 to the text that you want to appear here 5 1 Network Settings When the Device communicates with the PC over Ethernet you need to check the following settings IP Address The IP address is 192 168 1 201 by default and can be changed as required the IP address of the Device and that of the PC cannot be duplicated Subnet Mask The subnet mask is 255 255 255 0 by default and can be changed as required Gateway The gateway is 0 0 0 0 by default If the Device and the PC are not located in the same network segment you need to set the gateway When the Device communicates with the PC over serial ports RS232 RS485 you need to check the following settings RS232 This parameter is used to enable or disable the RS232 communication If the RS232 communication cables are used set this parameter to ON RS485 This parameter is used to enable or disable the RS485 communication If the RS485 communication cables ar
10. Shortcut Def Access Control Set and Firmware Update to enable the device to meet user requirements to the greatest extent in terms of functions and display Settings e de yr oi General Add User User Mgt Comm Display 4 Fingerprint A j ee lt A RB a ata Mgt Date Time Log Settings Sond 2 Access Control Set Auto Test Dn Upload Sys Info E T SN Exit A Exit j 51 MultiBio700 User Manual 1 0 6 1 General Parameters Keyboard Clicks This parameter is used to set whether General to generate beep sound in response to every keyboard PAPA touch Select ON to enable the beep sound and select AAA OFF to mute Volume Voice Prompts This parameter is used to set whether to Koigi play voice prompts during the operation of the Device Select ON to enable the voice prompt and select OFF to mute Volume This parameter is used to adjust the volume of voice prompts Lock Power Key This parameter is used to set whether la z jl gt ON High gt Disable to lock the power key Select ON to disable the power key If you select OFF and press the power key the Device will be shut down in three seconds 52 Error Use the Home tab to apply jx 1 to the text that you want to appear here 6 2 Interface Parameters Language This parameter is used to display the current language used by the Device For multilingual capable Devices you can switch between
11. a prompt message yyy User ccess and automatically return to the Add User interface If the enrollment fails the system will display a prompt message and return to the Enroll Fingerprint interface In this case you need to repeat the operations of step 2 4 You can back up the enrolled fingerprint of a user by pressing Fingerprint A user can enroll 10 fingerprints at maximum 5 Press Save to save current information and return to the previous interface Press Exit to return to the previous interface without saving current information 22 Error Use the Home tab to apply 7 1 to the text that you want to appear here Enroll Fingerprint 201 0 Enroll Fingerprint 201 0 Add User Password Face Enrolled Successfully Place Finger Quality Group No 1 Role User Photo User Access 23 MultiBio700 User Manual 1 0 3 4 Enrolling a Password 1 Press Password on the Add User interface to display Addi ser the password management interface 2 On the displayed keyboard interface enter a password and press OK Re enter the password according to the co kaus system prompt and then press OK Group No 1 45 Tip The device supports the 1 to 8 digits Role User passwords by default 3 After the password is entered an interface is displayed Teper as shown below Press Save to save current information and return to the previous
12. apply 7 1 to the text that you want to appear here 7 Data Management Through the Data Mot Data Mgt menu you can perform A i yT or Delete Transactions management of data stored SS Eee Add User User Mgt Delete All Data on the device for example _ __z deleting the attendance ye ad P no record all data and Sn promotional pictures AA purging management rights and resetting the device to PARRA factory defaults ES 1 Delete Transactions Delete all the attendance records 2 Delete All Data Delete all the information of enrolled personnel including their fingerprints face images and attendance records 3 Clear Administrator Change all administrators to ordinary users 4 Restore to Factory Settings Restore all parameter settings on the device to factory settings 4S Notice The employee information and attendance records will not be deleted during restoration to factory settings 5 Query Record After check in successfully the employee s attendance records are saved in the device You can easily query these attendance records User ID Enter the user ID of the employee to query If this field is left blank you can query the attendance records of all the employees If you enter a user ID you can query the attendance record of the employee with this user ID Query Time Period Select a time period to query including the customized time 74 Error Use the Home tab to
13. apply jx 1 to the text that you want to appear here period yesterday this week last week this month last month and all time periods Start and End When you select a customized time period you need to input a start time and an end time When you select other options for time period the start and end time will be automatically adjusted to the related time After setting the query conditions press Query and the records that meet the specified query conditions will be displayed on screen Select the row where the desired record is located you can query the detailed information of this records Record User ID All Att Log Total Record 16 19 35 19 35 15 56 15 55 15 55 15 55 15 16 15 11 15 11 15 10 19 35 16 25 15 55 15 55 15 54 15 06 Query Time This Week Period StartDate StartTime 00 00 EndDate 2010 10 26 EndTime 23 59 2010 10 24 CU A Press User ID and enter the edit interface input the ID number and press Query the query result will display as below 75 MultiBio700 User Manual 1 0 Att Log User 1D 2 19 35 19 35 15 56 15 55 15 55 15 55 15 16 15 11 15 11 15 10 76 Error Use the Home tab to apply 7 1 to the text that you want to appear here 8 Date Time Setting 8 1 Set Date Time The date and time of the device must be set accurately to x ensure the accuracy of attendance time er 1 Press Menu on the initial interface to display the ma
14. binary bits output by Wiegand as well as the meaning of each bit The data bits output by Wiegand can be a card number C site code s facility code f manufacturer code m and parity bits p Parity bits define the check mode of each bit in data bits and ensure the correctness of data bits during transfer through the parity check The parity bits can be set to odd check 0 even check e and both odd check and even check b There exists a one to one correspondence relationship between the data bits and parity bits For example the Wiegand26 can be customized as follows Definition of data bits pssssssssccccccccccccccccp Definition of parity bits eeeeeeeeeeeeeo000000000000 4S Note Wiegand26 consists of 26 bits The first bit is User Define Format the even parity bit of bits 2 to 13 the 26 bit is the odd Tease parity bit of bits 14 to 25 the second to the ninth bits are the site code the 10 to the 25 bits are the card number sel a For details about the Wiegand protocol see Appendix 3 MEA Introduction of Wiegand To customize Wiegand format proceed as follows 1 Select Define Format and the Set key is then enabled ES Error Use the Home tab to apply 7 1 to the text that you want to appear here 2 Press Set to display the User Define Format interface as shown in the following figure 3 Click the entry box below Card Format to display the following interface Display Input
15. interface Press Exit to return to the previous interface without saving current information Add User Input Password Group No 1 Role User Photo User Access 24 Error Use the Home tab to apply 7 1 to the text that you want to appear here 3 5 Enrolling a Face 1 Press Face on the Add User interface to display the face enrollment interface 2 On the displayed face enrollment interface turn your head to the left and right slightly raise and lower your head according to the voice prompts so as to enroll different parts of your face into the system to assure accurate verification See 1 2 Enrollment Face Expression 3 If your face image is enrolled successfully the system will display a prompt message and automatically return to the Add User interface Add User 4 Press Save to save current information and return to the previous interface Press Exit to return to the previous interface without saving current information Add User Group No 1 Role User Please adjust your pose and O ey distance to the machine Photo User Access Exit qQREAA A 25 MultiBio700 User Manual 1 0 3 6 Entering a Group No During face enrollment the device automatically allocates a group No starting from 1 for every user in sequence When the number of users in Group No 1 reaches the upper limit the rest users fall under Group No 2 automatically Up to 100 face images can b
16. menu After editing B skk di Facer press Save to save current information and return to game invalid previous interface press Exit to directly return to MINAS a i i f Time Zone 2 00 previous interface without saving current information WA Time Zone 3 00 N Exit Delete Save 65 MultiBio700 User Manual 1 0 3 Delete group time zone Select the line to be deleted Press Delete to popup the confirm interface as follows Select Yes to delete this holiday otherwise select No to cancel the operation Edit Group Code 3 VerType FP Holiday No gt Valid Time Zone 1 01 Time Zone 2 00 Are You Sure 66 Error Use the Home tab to apply jx 1 to the text that you want to appear here 6 7 4 Unlock Combination Setting Make various groups into different access controls to achieve multi verification and improve security An access control can be made up of 5 groups at most 1 Add Unlock Combination Unlock Combination Setting 1 Enter holiday add Combination Setting interface press Mi 01 00 00 00 00 the key to edit the items 2 Press the touch screen number key to set the value after setting press OK to save and press X for exit and return to previous interface 3 Press Save to save current information and return to previous interface press Exit to directly return to previous interface without saving current information Add an Unlock Comb
17. none Out anti pass back Only user s last record is in record can the door be open In anti pass back Only user s last record is out record can the door be open Device status There are three options Control in control out and none 94 Error Use the Home tab to apply 7 1 to the text that you want to appear here Control in When it is set the verified record on the device is in record Control out When it is set the verified record on the device is out record None When it is set close the device s anti pass back function 3 Modify device s Wiegand output format When the two devices are communicating only Wiegand signals without device ID are received Enter device menu gt communication option gt Wiegand option or enter software basic setting device management Wiegand to modify defined format as wiegand26 without device ID 4 Enroll user The user must be on master machine and slave machine at the same time and user PIN must be the same Therefore it is necessary to enroll user on master machine and slave machine at the same time 5 Connection instruction Wiegand communication is adopted for master machine and slave machine Refer to the following for connection Master Slave INDO lt gt WDO IND1 lt gt WD1 GND lt gt GND 95 MultiBio700 User Manual 1 0 Appendix 6 Statement on Human Rights and Privacy Dear Customers Thank you for choosing the hybrid b
18. set the value VerType FACE amp FP VerType Select the Group Verify Type eee eve Holiday No Select if the Time zone is valid in holiday a ae FA Time Zone Select the Group Time Zone Time Zone 2 00 i 2 After editing press Save to save current information HE 00 and return to previous interface press Exit to directly return to previous interface without saving current information E E Exit Save SF Note 1 RF means ID Card verification Only the products with a built in ID card module support the ID card verification 2 For Multi combination verification please refer to Appendix 4 Multi combination Authentication Mode 64 Error Use the Home tab to apply 7 1 to the text that you want to appear here VerType VerType FACE amp PIN FP RF PW PWaRF PIN amp FP FPRPW FPRRF FP amp PW amp RF FACE amp PW PINSFP2PW PFACESRF FP FP amp RF PIN PW RF s FACE amp FP amp RF PFACEZ2PIN FPIRF gt FACE amp FP amp Pw G PWIRF G FPIPW lt Exit Morei Exit N k A 2 SES Notice 1 If holiday is effective only when there is intersection between group zone and holiday time zone can the group member open the door 2 If holiday is ineffective the access control time of group member won t be affected by holiday 2 Edit group time zone Edit Group Select the line to be edited Press OK directly or press EE 1 menu to select edit in operating
19. universal Wiegand formats Wiegand34 Data bits pccccccccccccccccccccccccccccccccp Parity bits eeeeeeeeeeeeeeeeCO00000000000000000 Note Wiegand34 consists of 34 bits The first bit is the even parity bit of bits 2 to 17 the 34 bit is the odd parity bit of bits 18 to 33 the second to the ninth bits are the site code the 10 to the 25 bits are the card number Wiegand37a Data bits pmmmmsssssssssssscccccccccccccccccccp Parity bits oceobeobeobeobeobeobeobeobeobeobeobeoe Note Wiegand37a consists of 37 bits The first bit is the odd parity bit of bits 3 4 6 7 9 10 12 13 15 16 18 19 21 22 24 25 27 28 30 31 33 34 and 36 the 37 bit is the odd parity bit of bits 2 4 5 7 8 10 11 13 14 16 17 19 20 22 23 25 26 28 29 31 32 34 and 35 bits 4 7 10 13 16 19 22 25 28 31 and 34 48 Error Use the Home tab to apply jx 1 to the text that you want to appear here participate in both odd and even parity check Bits 2 to 5 are manufacturer code bits 6 to 17 are the site code bits 18 to 36 are the card number Wiegand37 Data bits ommmiffftittfifssssssccccccccccccccccp Parity bits eeeeeeeeceeeeeeeeee0000000000000000000 Note Wiegand37 consists of 37 bits The first bit is the even parity bit of bits 2 to 18 the 34 bit is the odd parity bit of bits 19 to 36 the second to the fourth bits are the manufacturer code the 5 to the 14 bits are facilitate code the 15 to the 20 bits
20. Expressions YES 3 Recommended Posture pose vs poor Posture pose SS Note During enrollment and verification try to have a relaxed unstrained face expression and stand upright MultiBio700 User Manual 1 0 1 2 Enrollment Face Expression During the enrollment position your head such that your face appears in the center of the device display window The device will prompt you how to move your head Follow the voice prompts by first gently turning your head left then right Then your head gently down then up and so on There slight variations of head angles will help the device better recognize your face when you attempt verifying The enrollment face experssion as follows Look ahead Look at screen Bow down Turn left Turn right Error Use the Home tab to apply jx 1 to the text that you want to appear here 1 3 Finger Placement Recommended fingers The index finger middle finger or the ring finger the thumb and little finger are not recommended because they are usually clumsy on the fingerprint collection screen 1 Proper finger placement The finger is flat to the surface and centered in fingered guide 2 Improper finger placement Not flat to the surface Off center Slanting Off center Please enroll and verify your fingerprint by using the proper finger placement mode We shall not be held accountable for any consequences arising out of the degradation in verification perf
21. IN FP RF PW FP amp PW FP amp RF FACESFP FACESPW FACESRF FP PW RF FACE amp PIN FP RF PW RF FP PW PWE8RF PIN amp FP FP amp PW amp RF PINSFPSPW FPS RF PIN FACESFP8RF FACE amp FP amp PW etc For the detail please refer to Appendix 4 Multi combination Authentication Mode 42 Note RF means ID Card verification Only the products with a built in ID card module support the ID card verification VerType PWIRF FPIPW FACE amp PIN FP RF PW PWERF I PIN amp FP FPRPW k FP amp AF FP amp PW amp RF FACE amp FP FACEBPW PIN amp FPRPW FP amp RF PIN FACE amp RF gt FACE amp FP amp RF a oa FACESPIN FP RF e FACES FP8PW FP RF lt Exit Morei Exit A A N Here is the combination verification operation we use the FACE amp FP verification for an example If you verify fingerprint first and then the face verify operation as follows 1 The default main interface is the fingerprint verification mode see the figure below 2 Press your finger on the fingerprint collector by adopting the proper finger placement For details see 1 3 Finger Placement 3 If the verification is successful the device enter the 1 1 face recognition mode 15 MultiBio700 User Manual 1 0 Compare the face in a proper way For details see 1 1 Standing Position Posture and Face Expression 4 If the verification is successful the device prompt Verified The system will
22. MENU 1 1 11 MultiBio700 User Manual 1 0 1 8 2 Face Verification 1 1 face verification In the 1 1 face verification mode the device compares 10 10 25 Monday D current face collected through the camera with that in relation to the user ID entered through keyboard Adopt this mode only when it is difficult to recognize the face 1 Press 1 1 on the screen or 1 1 keyboard to enter the Check In 1 1 recognition mode 2 Enter user ID and then press the 1 1 Face icon to enter 1 1 face recognition mode If the prompt Unregistered user is displayed the user ID is not exist 3 Compare the face in a proper way For details see 1 1 Standing Position Posture and Face Expression 4 If the verification is successful the device prompt Verified The system will return to the main interface if the verification is not passed within 20 seconds Please input user ID 10 10 25 Monday D Score 72 4 User ID 2 Name sun Verify 1 1 Face Verified 12 Error Use the Home tab to apply 7 1 to the text that you want to appear here 1 8 3 Password Verification In the password verification mode the device compares the password entered with that in relation to the user ID 1 Press 1 1 on the screen or 1 1 keyboard to enter the password verification mode 2 Enter the user ID and then press the Key icon to enter password verification mode If the prompt Unregistere
23. MultiBio700 User Manual Version 1 0 Date Oct 2010 About This Manual This document introduces the user interface and menu operations of MultiBio700 For the installation please refer to Installation Guide Table of Contents TABLE OF CONTENTS LSINSTRUCTION FOR USE sicir eain araa a 1 1 1 STANDING POSITION POSTURE AND FACE EXPRESSION cccsseeseeeeeeeeeeeees 1 2 ENROLLMENT FACE EXPRESSION ccsseisssrsseessccsavdsssesneswebeesacnsows seaenswdssenvavwss cars 2 SINGER PONG EMI INI orcas 3 LAUSE OF TOUCHSCREEN caracol 4 es F OUCH OPERAN So 5 LOAPPEARANCE OF DEVICE sus ia a EA T LAMAN INTERFACE aen ee eE E EE 8 ls VERIFICATIONUVIODES inicial onea AE N OEE TOSES 10 t81 Fingeipnnt VONINCATON ise rious ite eile ae e 10 L82 FACE VENCIO AA diacestebsaeetaees 12 1 8 3 Password Verification oooocooonnnnnnonconconnnananononanannnccnnnanoconnna raros Ta 18 4 ID Cal Vertical Mai E E AE 14 L89 Combination VETINCAUON Meta idad iii 15 Z MAIN MENU usa Rocca Rocco 17 S ADD USER AA E e o y a a aaae 19 Sel ENTERING AC SBR ID rasian a A A ees eaane 20 5 2 ENTERING A NAMES decree Ruane nisin sd aie Cuan Raed 21 3 ENROEPING A FINGERPRIN Tila 22 964 ENROLLING ARAS WORD T O 24 JEN ENROLEING ARACENA T 25 5 0 ENTERING A GROUP N O eaa ao 26 2 MODIEY USER RIGH IS a 28 520 ENROLL PHOTOS nadando doods 29 II USERACCESS SETIN casina E A 30 MultiBio700 User Manual 1 0 3 I OENROLUING ANID CARD A e e ei e 33 USER MANAGEMEN L
24. Zone 2 AE 11 Duress FP Reg Duress FP Duress eee Time Zone and Duress FP Can Duress FP management 1 Verify Type VerType VerType 1 ro ea ne If a gt ona user use the group verify mode femm ihat Ke belong lo AA PYY amp RF PWERF PINGFP PIN amp FP 2 Individual verify mode PM i biik ART Select the verify mode for this a binaris See user instead of the group verify Mio a e FP amp RF PIN mode That will not effect the err Faccerranr other user in the group SraccerIn CS Eo racrerPaPW ES Note N Exit Morei 4 N Exit 1 Only the products with a built in ID card module support the ID card verification 2 For the verify type please refer to_Appendix 4 Multi combination Authentication Mode Only some type of device support Multi combination authentication mode 30 Error Use the Home tab to apply jx 1 to the text that you want to appear here 2 Time Zone 1 Group Time Zone If the user use the group time zone that he belong to 2 Individual time zone Select the time zone of this user instead of the group time zone That will not effect the other user in the group 3 Duress FP Enroll a new duress fingerprint or cancel an exist one In any situation only if the enrolled duress fingerprint is verified it will trigger the duress alarm Duress FP management 1 Register Duress FP Press Reg Duress FP on the User Access interface to
25. according to user s recent in out record In record and out record must be matched This machine supports out in or 93 MultiBio700 User Manual 1 0 out in anti pass back When master machine is set as out anti pass back if user wants to come in and go out normally his recent record must be in or he cannot go out Any out record will be anti pass back refused For example a user s recent record is in his second record can be out or in His third record is based on his second record Out record and in record must match Notice If customer has no record before then he can come in but cannot go out When the master machine is set as in anti pass back if the user wants to come in and go out normally his recent record must be out or he cannot go out Any out record will be anti pass back refused by the system Notice If the customer has no former record then he can go out but cannot come in When the master machine is set as out in anti pass back if the user wants to come in and go out normally if his recent record is out and in then his next record must be in and out operation 1 Select model Master machine Machine with Wiegand in function except for F10 reader Slave machine Machine with Wiegand Out function 2 Menu setting Anti pass back There are four options in out anti pass back out anti pass back in anti pass back and
26. ace card password rights group No and user access And add modify or delete the user information 17 2 EKA Comm Through this submenu you can set related parameters for communication between the device and PC including the IP address gateway subnet mask baud rate device No and communication password System Through this submenu you can set system related parameters including the basic parameters interface parameters fingerprint face and attendance parameters Keyboard definitions Access setting firmware update etc to enable the device to meet user requirements to the greatest extent in terms of functions and display Data Mgt Through this submenu you can perform management of data stored on the device for example deleting the attendance record all data clear administrator restore to factory settings and query records Date Time Through this submenu you can set the alarm time and duration or set the Bell Auto Test This submenu enables the system to automatically test whether functions of various modules are normal including the screen collector voice face keyboard clock tests and screen calibration Dn Upload Through this submenu you can import user information and attendance data stored in the device through a USB disk to related software or other fingerprint recognition equipment Sys Info Through this submenu you can browse the records and device information eM nne Any user can acc
27. and Hazardous Substances or Elements Parts Name Chip resistor Chip capacitor Chip inductor ESD components Buzzer Adapter MAC CO px e e e po px e e oe eo px e e e eo Chipdiode x o o o o px e e e fo px e e oe io px e e e fo ERA LAA ea o Indicates that this toxic or hazardous substance contained in all of the homogeneous Screws materials for this part is below the limit requirement in SJ T 11363 2006 x Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials for this part is above the limit requirement in SJ T 11363 2006 Note 80 of the parts in this product are manufactured with non hazardous environment friendly materials The hazardous substances or elements contained cannot be replaced with environment friendly materials at present due to technical or economical constraints 98
28. ata between the device and PC over network to enhance the transfer speed e e e a e e ei e ee MB eM eM eM MB MP MP MP eM MP MP MP BM MP MP eM eM BM MP BM BM BM BM BM BM BM BM BM BM BM BM BM BM BM BM BM Bw BM BM BM BM BM BM BM BM BM BM eB BM eS eS 40 a o a o a Error Use the Home tab to apply jx 1 to the text that you want to appear here 5 2 Wiegand Output Wiegand Format The system has two built in formats Wiegand 26 bits and Wiegand 34 bits and also supports the format customization function to meet individualized requiremenis Failed ID Refers to the value output by the system upon verification failure The output format is subject to the setting of Wiegand Format The default value scope of Failed ID is 0 65535 Site Code The site code is used for customized Wiegand format The site code is similar to the device ID but the site code is customizable and can be duplicated among different devices The default value 0 255 Wiegand Output Wiegand 26 Define 0 0 Pulse Width us 100 Failed ID Site Code Pulse Interval us 1000 Output gt User ID C Exit Save scope of the site code is Pulse Width Refers to the width of the Wiegand pulse in microseconds The default value scope of the pulse width is 1 1000 Pulse Interval Refers to the interval of the Wiegand pulse in microseconds The default value scope of the pulse width is 1 10000 Output Ref
29. atching is successful otherwise the matching is not successful The valid value scope is Te 55 120 The higher the threshold the lower the FAR and the higher the FRR and vice versa 1 1 N Threshold This parameter is used to set the threshold of matching between current face and the face Cat template enrolled in the Device in the 1 N verification mode If the similarity between current face and the face template enrolled in the Device is larger than this threshold the matching is successful otherwise the matching is not successful The valid value scope is 65 120 The higher the threshold the lower the FAR and the higher the FRR and vice versa The recommended thresholds are as follows Threshold FRR High Low Medium Medium 80 70 Low High 75 65 Exposure This parameter is used to set the exposure value of the camera Gain This parameter is used to set the gain value of the camera Quality This parameter is used to set a quality threshold for the face images obtained The Device accepts the face images and processes them by adopting the 56 Error Use the Home tab to apply Fx 1 to the text that you want to appear here face algorithm when their quality is higher than the threshold otherwise it filters these face images SS Note Improper adjustment of the Exposure Gain and Quality parameters may severely affect the performance of the Device Please adjust the Exposure parameter only under the gui
30. b Disable Mid 10 Bell Type Internal K Save 42 Notice Only some models have this function If you need it please contact our business representative or technician 79 Error Use the Home tab to apply 7 1 to the text that you want to appear here 9 Auto Test The auto test enables the system to automatically test whether functions of various modules are normal including the screen collector voice face keyboard and clock tests Auto Test pS gt n A Ri or Test Screen Add User User Mgt Test Fingerprint a Test Yoice a Test Face System Data Mgt Date Time Test Keyboard Sys Info N Exit 1 Test Screen The device automatically tests the display effect of the color TFT display by displaying full color pure white and pure black and checks whether the screen displays properly You can continue the test by touching the screen or exit it by pressing Exit 2 Test Fingerprint The device automatically tests whether the fingerprint collector works properly by checking whether the fingerprint images are clear and acceptable When the user places his her finger in the fingered guide the collected fingerprint image is displayed on the screen in real time Press Exit to exit the test 3 Test Voice The device automatically tests whether the voice files are complete and the voice quality is good by playing the voice files stored in the device You can continue the test by touching t
31. ccscccccsscccscscccccescccsees 77 MS EL DAT IMEI oda 71 PAETE ES IE E AE EE EA IAE ETE I EA E AET 78 AUTO TEST A a a TS 80 10 USB DISK MANAGEMENT eeesseessseecsseccsscccsseecsscccsseecsscecsseecsseessscessse 82 11 SYSTEM INFORMATION eeeeeeeessssecsssssecssssccccsssscccoseccccossccccssececossecccsseseeo 83 12 APPENDIX 0 A A AE en On 84 APPENDIX TO INPUT INSTRUCTIONS cceccsceececcecceccscescecctccscescescscescescesens 84 APPENDIX 2 INTRODUCTION OF WIEGAND 0cccsccecceccecceccecccecctccuccescescesceees 86 APPENDIX 3 PHOTO ID FUNCTION cccecceccecececcecceccscescccscescescescssescescucens 88 APPENDIX 4 MULTI COMBINATION AUTHENTICATION MODE XK cccccccceceeeeeees 89 APPENDIX 5 ANTI PASS BACK Wauconda a 93 APPENDIX 6 STATEMENT ON HUMAN RIGHTS AND PRIVACY 0sceccecceccecescecees 96 APPENDIX 7 ENVIRONMENT FRIENDLY USE DESCRIPTION ccccecececececececes 98 Error Use the Home tab to apply 7 1 to the text that you want to appear here 1 Instruction for Use 1 1 Standing Position Posture and Face Expression 1 Recommended standing distance from device For users 5 6 feet tall 1 5m 1 85m we recommend users stand about 2 feet 0 5m from the wall When viewing your image on the device display window a step away if your image appears too bright Step closer if your image appears too dark e 0 5M 2 Recommended face Expressions vs poor
32. ction is the effective time zone within 24 Monday 00 00 4 hours everyday Every user can set 3 time zones or Tuesday 00 00 E 4 exists among the three zones It is effective if only one is satisfied Every time section format is HH MM HH MM ieee sess namely accurate to minute Friday 00 00 Wednesd 00 00 4 ar 23 59 23 59 23 59 4 E If end time is smaller than start time 23 57 23 56 the EMM whole day is forbidden If end time is bigger than start er Save time 00 00 23 59 it is effective section A Effective time zone for user unlocking 00 00 23 59 or end time is bigger than start time 4 Notice System default time zone 1 as whole day open namely the new enrolled user is unlocking 61 MultiBio700 User Manual 1 0 6 7 2 Holiday setting Special access control time may need during holiday It is Holiday Set different to modify everybody s access control time So a holiday access control time can be set which is applicable for all employees 1 Add holiday 1 Enter holiday add interface press the key to edit the items 2 Press the touch screen number key to set the value after setting press OK to save and press X for exit and return to previous interface 3 Press Save to save current information and return to previous interface press Exit to directly return to previous interface without saving current infor
33. d user is displayed the user ID is not exist 3 Enter the password and press the OK icon to start the password comparison 4 lf the verification is successful the device prompt Verified otherwise the device prompt Verify fail and return to password input interface Please input user ID Input Password 10 10 25 Monday gt a Check In 10 10 25 Monday er J User ID 2 Name sun Verify Password Verified 1 1 13 MultiBio700 User Manual 1 0 1 8 4 ID Card Verification 42 Note Only the products with a built in ID card module 10 10 25 Monday gt support the ID card verification In the fingerprint verification mode the device compares current ID Card collected by the Card Reader with all ID Card data on the device Check In 1 Swipe your ID Card on the Card Swipe Area by adopting the proper way For the Card Swipe Area see 1 6 Appearance of Device 3 If the verification is successful the device prompt Verified 4 If the verification is not successful the device prompt Card not Registered 10 01 19 Tuesday 10 01 19 Tuesday gt Y gt N 7 lt User ID 9 Card No 0000205930 Name Linda Verify PIN Card Verify CARD Verified Not Enrolled 14 Error Use the Home tab to apply 7 1 to the text that you want to appear here 1 8 5 Combination Verification The device support 20 verification modes including FACE amp P
34. dance of the after sales service personnel from our company 57 MultiBio700 User Manual 1 0 6 5 Log Settings Log Alert When the available space is insufficient to store the specified number of attendance records the Device will automatically generate an alarm Value scope 1 99 Dup Punch Period m If a user s attendance record already exists and the user punches in again within the specified period unit minute his her second attendance record will not be stored Value scope 1 60 minutes Log Settings Log Alert Dup Punch Period m 9 E a 58 Error Use the Home tab to apply jx 1 to the text that you want to appear 6 6 Keyboard Definitions Define touch screen functional shortcut keys here 1 Press Shortcut Def to display the Edit interface as shown below Shortcut Def Status Status Status Status Undefine lt Exit 2 If you want to cancel the shortcut key press Status to enter the edit interface select the value to Undefine Check In Check Out OT In OT Out Function Code Label Auto Switch Edit 1 Check In gt Status 0 OFF Edit 1 Function Status Code 0 Label Check In Auto Switch Sunday 00 00 Monday 00 00 Tuesday 00 00 Yvednes 00 00 day Thursda 99 99 Friday 00 00 Yy Saturday 00 00 C Exit Save 3 Edit the item Code select Label Six attendance state option Selec
35. different languages through this parameter Toolbar This parameter is used to display style of the shortcut keys on the initial interface It can be set to Auto Hide and Permanent Display By selecting Auto Hide you can manually display or hide the toolbar By selecting Permanent Display you can permanently display the toolbar on the initial interface Sleep Time S This parameter is used to specify a Language ENG Toolbar gt Auto Hide Sleep Time m 0 period after which the Device is put in sleep mode if not operated within this period You can bring up the Device from sleep by pressing any key or touching the screen 53 MultiBio700 User Manual 1 0 6 3 Fingerprint Parameters 1 1 Threshold This parameter is used to set the Hagergetnt threshold of matching between current fingerprint and PMA the fingerprint template enrolled in the device in the 1 1 PPP 35 45 verification mode If the similarity between current ittimnmecsen TT fingerprint and the fingerprint template enrolled in the Fingerprint Image Always Show Device is larger than this threshold the matching is MS successful otherwise the matching is not successful 1 N Threshold This parameter is used to set the threshold of matching between current fingerprint and the fingerprint template enrolled in the device in the 1 N verification mode If the similarity between current fingerprint and the fingerprin
36. display the Enroll Fingerprint interface On the displayed Enroll Fingerprint interface place your finger on the fingerprint collector properly according to the system prompt For details see 1 3 Finger Placement User Access User ID 201 VerType Group Yerif Mode Time Zone I gt Group Set Time Zone 1 0 0 D Time Zone 2 Time Zone 3 Duress FP Reg Duss FP P s Enroll Fingerprint 201 0 Enroll Fingerprint 201 0 Place Finger Enrolled Successfully Quality Quality 70 31 MultiBio700 User Manual 1 0 2 Cancel duress FP Press Can Duress FP on the User Access interface to popup the confirm message Select YES to delete the enrolled duress FP otherwise select NO to cancel the operation User Access User Access User ID 201 User ID 201 VerType Group Verif Mode VerType Group Verif Mode a Time Zone b Set Interval Time Zone gt Set Interval Time Zone 1 Time Zone 1 Time Zone 3 Are You Sure 0 Time Zone 2 0 Time Zone 2 0 Duress FP Can Duress FP Done 32 Error Use the Home tab to apply 7 1 to the text that you want to appear here 3 10 Enrolling an ID Card 1 Press Card on the Add User interface to display the User Info Enroll Card interface i User ID 201 2 The Punch Card interface pops out as shown below LS Swipe your ID card properly in the swiping area For a details see 1 6 Appearance of
37. e enrolled in Group No 1 and only 50 face images can be enrolled in other groups If you use the group No allocated by the device you may skip this section 1 Press Group No on the Add User interface to display the group No management interface 2 On the displayed keyboard interface enter your group No and press OK Add User User Access 3 After the group No is entered an interface is displayed as shown below Press Save to save current information and return to the previous interface Press Exit to return to the previous interface without saving current information BS Tip A valid group No contains 1 24 digits Please remember your own group No 26 Error Use the Home tab to apply 7 1 to the text that you want to appear here Add User 3 O J 6 E b Role User Photo User Access Please Input the Group No 1 9 8 2 MultiBio700 User Manual 1 0 3 Modify User Rights 42 Note There are two types of rights respectively granted to two types of users the ordinary users and administrators Ordinary users are only granted the rights of face fingerprint or password verification while administrators are granted the access to the main menu for various operations apart from having all the privileges granted to ordinary users 1 On the Add User interface press Role User to change the user into an administrator 2 After the modification is done the interface
38. e 00 00 2 Sunday Bell Date Define Monday Ring Tone bell01 wav Tuesday Yolume High a Wednesday Repeat Tu gt Thursday Stat i ate le Disable Friday Bell Type Internal di Saturday Exit Save K Exit Save 1 Add a bell 1 The displayed bell setting interface lists all the bells Click Add to display the Ada interface 2 On the Add interface set the following parameters Bell Time This parameter is used to set a time point when the Device automatically plays a bell ring tone everyday Bell Date This parameter is used to set which day the device automatically plays a bell ring tone 78 Error Use the Home tab to apply jx 1 to the text that you want to appear here Ring Tone This parameter is used to set the bell ring tone Volume This parameter is used to set the volume of ring tone Repeat This parameter is used to set the alarm times State This parameter is used to set whether to enable the bell Bell Type You can select between internal ringing or external ringing For internal ringing the ring tone is played by the loudspeaker of the device For external ringing the ring tone is played by an external electric bell that is wired with the device 2 Edit and delete a bell Edit Press a bell in the list on the bell setting interface to GASGG 00 00 display the Edit interface with the similar operation as Eb Define Add a bell Ring Tone bell01 wav Yolume Repeat State
39. e used set this parameter to ON Baud Rate This parameter is used to set the baud rate for the communication between the Device and the PC It includes five options 9600 19200 38400 57600 and 115200 The high baud rate is recommended for the RS232 communication to achieve high communication speed while the low baud rate is recommended for the RS485 communication to achieve stable low speed communication Device ID This parameter is used to set the ID of device from 1 to 254 If the RS232 RS485 communication is adopted you need to enter the device ID on the software communication interface Comm Key To enhance the security of attendance data you can set a password for the connection between the Device and PC Once the password is set you can connect the PC with the Device to access the attendance data only after entering the correct password The default password is O that is no password Once a password is set you need to enter this password before connecting the PC software with the Device otherwise the connection is unsuccessful 1 to 6 digits passwords are supported 39 MultiBio700 User Manual 1 0 Wy Wwny 37nmr 3nr 3 3 3 f 3 3nf 3m yr 3m nym mn mn mn mn mm wm mM MP mM MP Mm MM mM mM MP mM mM mM mM mM mM mM mM mM mM mM MP mM mM Mw mM eM mM mM mM mM mM mM eM KM NM Ke Considering the massive data including the fingerprint and face templates Istored in the device it is recommended to transfer the d
40. ed 1 FACE 1 N PW OK FP 2 FP PW OK FACE 1 1 3 PIN FP 1 1 PW OK FACE 4 PIN FACE 1 1 PW OK FP 5 PIN PW OK FP FACE BS Note For combined verification it is better to enroll all the elements in need of the using verification mode or verification will fail For example User A use fingerprint for enrollment while password is used for verification then the user cannot pass the verification 92 Error Use the Home tab to apply 7 1 to the text that you want to appear here Appendix 5 Anti Pass Back overview Sometimes some illegal person follows the other one into the gate which will bring security problem To prevent such risk this function is enabled In record must match out record or the gate won t be open This function needs two machines to work together One is installed inside the door master machine hereinafter the other is installed outside the door slave machine hereinafter Wigand signal communication is adopted between the two machines IN Master machine slave machine user UT working principle The master machine has Wigand In and slave machine has Wigand Out Connect Wigand Out of slave machine to Wigand In of master machine Wigand output from slave machine must not own machine ID The number sent to master machine from slave machine must be found in the master machine function Judge whether it is anti pass back
41. ers to the contents output upon successful verification You can select the User ID or Card Number as the output 4 MultiBio700 User Manual 1 0 5 2 1 Wiegand 26 bits Output Description The system has a built in Wiegand 26 bits format Press Wiegand Format and select Standard Wiegand 26 bits The composition of the Wiegand 26 bits format contains 2 parity bits and 24 bits for output contents User ID or Card Number The binary code of 24 bits represent up to 16 777 216 0 16 777 215 different values 1 2 25 26 User ID Card Number Odd parity bit Definition of Fields Even parity bit Judged from bit 2 to bit 13 The even parity bit is 1 if the character has an even number of 1 bits otherwise the even parity bit is 1 User ID Card User ID Card Number Card Code 0 16777215 Number bit 2 bit 25 Bit 2 is the Most Significant Bit MSB Odd parity bit Judged from bit 14 to bit 25 The odd parity bit is 1 if the character has an even number of 1 bits otherwise the odd parity bit is O For example for a user with user ID of 12345 the enrolled card number is 0013378512 and the failed ID is set to 1 1 When the output is set to User ID the Wiegand output is as follows upon successful verification 00000000000110000001110011 Even parity bit User ID Binary code of 12345 Odd parity bit 2 When the output is set to Card Number the Wiegand output is as follows upon
42. ess the main menu by pressing the Menu key if the system is free from administrators After administrators are configured on the device the device needs to verify the administrators identity before granting them access to the main menu To ensure device security it is recommended to set an administrator when using the terminal initially For detailed operations see 3 7 Modify User Rights mmm www www ww ww ww ww ww ww www www www www ww www ww ww iii i i i i i i i i i i ee eS Error Use the Home tab to apply 7 1 to the text that you want to appear here 3 Add User Press Add on the User Mat interface to display the Add User interface as shown below User ID Enter a user ID 1 to 9 digits user IDs are supported by default Name Enter a user name 12 characters user names are supported by default Fingerprint Enroll a user s fingerprint and the Device displays the number of enrolled fingerprints A user can enroll 10 fingerprints at maximum Password Enroll a user s password 1 to 8 digits passwords are supported by default Face Enroll a user s face Group No Set the group that the user belongs to Valid group No 1 24 Role Set the rights of a user A user is set to ordinary user by default and can also be set to administrator Ordinary users are only granted the rights of face fingerprint or password verification while administrators are granted the access to the main menu for various operations a
43. face and output protocol Wiegand26 defines the interface between the card reader and controller used in the access control security and other related industrial fields Wiegand26 helps standardize the work of the card reader designers and controller manufacturers The access control products manufactured by our company are also designed by following this protocol Digital Signals The figure below is a sequence diagram in which the card reader sends digital signals in bit format to the access controller In this sequence diagram Wiegand follows the SIA s access control standard protocol for the 26 bit Wiegand card reader one pulse time ranges between 20us and 100us and the pulse jump time ranges between 200us and 20ms Datai and Data0 are high level larger than Vol signals till the card reader prepares to send a data stream The asynchronous low level pulse smaller than Vol generated by the card reader is sent to the access control panel The saw tooth wave as shown in Figure below through Data1 or Data0 Data1 and Data0 pulses will neither overlap nor be generated synchronously The table below lists the maximum and minimum pulse width a consecutive pulse and pulse jump time time between pulses allowed by the F series fingerprint access control device 86 Error Use the Home tab to apply jx 1 to the text that you want to appear here Figure Sequence Diagram Data 1 Signal i i i i i _ posen A Aaa O dl att i
44. he existing photo in related to the user ID 4 To download user photos select USB Disk Management gt Download gt Download User Photos A folder with the name of photo will be automatically created on the USB disk and all downloaded user photos are stored under this folder 88 Error Use the Home tab to apply Fx 1 to the text that you want to appear here Appendix 4 Multi combination Authentication Mode Besides this function only is owned by the fingerprint access control machine that has been appointed the most fingerprint machine only has two way to verified by fingerprint and password we provide a personal or group Multi combination Authentication Mode for high security Access control area verification type main include five elements that are User Number PIN Fingerprint FP Face FACE Password PW and RF card RF which can combine into multi combination ES Note The RF card is used for ID Card verification the function of ID card verification only is validity in the machine which ID card function is provided with These symbols illustrate what follow the table different means e is or e follow next operation e amp is and e FACE Face e FP fingerprint e PWD Password e RF RF card e PIN user ID If Fingerprint Face Password and Card has been used to enroll user the verification procedure is follow FACE amp PIN FP PW RF FACE PIN or RF or PW or RF is verif
45. he screen or exit it by pressing Exit 4 Test Face The device automatically tests whether the camera works properly by 80 Error Use the Home tab to apply jx 1 to the text that you want to appear here checking whether the collected face images are clear and acceptable Press Auto Test to exit the test 5 Test Keyboard The device tests whether every key on the keyboard works normally Press any key on the Keyboard Test interface to check whether the pressed key matches the key displayed on screen The keys are dark gray before pressed and turn blue after pressed Press Exit to exit the test 6 Test Time The device tests whether its clock works properly by checking the stopwatch of the clock Touch the screen to start counting and touch it again to stop to check whether the counting is accurate Press Exit to exit the test 7 Screen Calibration You can perform all the menu operations by touching the screen with one of your fingers or a touch pen When the touch screen is less sensitive to the touch you can perform screen calibration through menu operations The Screen Calibration Operation 1 Press Menu on the initial interface to display the main menu interface 2 Press Calibration on the Auto Test interface to display the screen calibration interface 3 Touch the center of the cross 4 Repeat Step 3 following the move of the icon to different locations on the screen 5 Touch the center
46. ied 1 PIN FACE 1 1 2 FP 1 N 3 PIN PW OK 4 RF 1 N FP amp PW FP PW are verified 1 FP 1 N PW OK 89 MultiBio700 User Manual 1 0 2 PIN FP 1 1 PW OK AS PIN PW OK FP 1 RF FP 1 1 2 FP 1 N RF 3 PIN FP 1 1 RF FACE amp FP FACE FP are verified 1 FP 1 N FACE 2 FACE 1 N FP 3 PIN FACE 1 1 FP 4 PIN FP 1 1 FACE FACERPW 1 FACE 1 N PW OK 2 PIN FACE 1 1 PW 3 PIN PW FACE 1 FACE 1 N RF A PIN FACE 1 1 RF RF 1 N FACE FP is verified PIN FP 1 1 FP 1 N Only verify PW is verified TE PIN PW Ok RF is verified FACE amp PIN FACE PIN are verified PIN FACE 1 1 90 Error Use the Home tab to apply jx 1 to the text that you want to appear e eee 1 PIN FP 1 1 2 RF 1 N 3 FPCUN PWR 1 PIN PW OK FP PW FP or PW is verified 1 PIN FP 1 1 2 FP 1 N a 3 PIN PW OK PIN amp FP PIN FP are verified PIN FP 1 1 1 FP 1 N PW OK RF 2 PIN FP 1 1 PW OK RE 3 RF 1 N PW OK FP 4 PIN PW OK FP 1 1 RF PIN amp FP amp PW PIN FP PW are verified 1 PIN PW OK FP 1 1 2 PIN FP 1 1 PW 0K 1 RE FP 1 1 2 FP 1 N RF 3 PIN FP 1 1 FACE amp FP amp RF FACE FP RF are verified 1 FACE 1 N FP RF 2 FP FACE 1 1 RF 91 FACE amp FP amp PW MultiBio700 User Manual 1 0 3 RF 1 N FACE FP 4 PIN FP 1 1 FACE RF 5 PIN FACE 1 1 FP RF FACE FP PW are verifi
47. in PARA SE menu interface 2 Press Time Date on the main menu interface to display the time setting interface System 3 Select the desired date and time by pressing the N parameter For the time format there 10 format to select gt Both the 12 hour and 24 hour time systems are SES supported 4 Press Save to save current information and return to the previous interface Press Exit to return to the previous interface without saving current information Date Format Y YIMM IDD YY MM DD MM DD YY B MM DDIYY MM DD YY Date Time Date 2010 10 26 Time 15 00 08 Date Format YY MM DD 24 Hour Time YES Bell Bell 2010 10 25 A DD MM YY DD MMIYY DD MM YY PYYYYMMDD 7 lt Exit Save N T1 MultiBio700 User Manual 1 0 8 2 Bell Setting Lots of companies need to ring their bells to signal the start and end of work shifts and they usually manually ring their bells or use electric bells To lower costs and facilitate management we integrate the time bell function into the device You can set the alarm time and duration for ringing the bell based on your requirements so that the device will automatically play the selected ring tone and trigger the relay at the alarm time and stop playing the ring tone after the set duration Press Bell on the Date Time menu to display the bell setting interface as shown in Figure below Add Bell Date Bell Tim
48. ination Code 2 Group 1 5 01 00 00 00 00 01 00 00 00 00 4 A cal 67 MultiBio700 User Manual 1 0 2 Edit Unlock Combination Select the line to be edited Press OK directly or press Edit an Unlock Combination Code 2 Group 1 5 01 00 00 00 00 menu to select edit in operating menu After editing press Save to save current information and return to previous interface press Exit to directly return to previous interface without saving current information Exit Delete Save 3 Delete Unlock Combination Select the line to be deleted Press Delete to popup Edit an Unlock Combination the confirm interface as follows Select Yes to delete Code 2 this holiday otherwise select No to cancel the Group 1 5 01 00 00 00 00 operation caca Are You Sure 68 Error Use the Home tab to apply jx 1 to the text that you want to appear here 6 7 5 Access control parameter Through the Access menu you can set the parameters of the electronic locks and related access control devices Lock Delay indicates the duration for the Device to place the electric lock in open state Value scope 1 10 seconds Door Sensor Delay indicates the delay in checking the Access Control Parameters None Lock Delay s Door Sensor Delay s Door Sensor ode Alarm Delay s Failure Alarm Thr NC Time Zone door sensor after the door is open If door sensor state is Fi a
49. iometric products designed and manufactured by us As a world renowned provider of biometric technologies and services we pay much attention to the compliance with the laws related to human rights and privacy in every country while constantly performing research and development We hereby make the following statements 1 All of our fingerprint recognition devices for civil use only collect the characteristic points of fingerprints instead of the fingerprint images and therefore no privacy issues are involved 2 The characteristic points of fingerprints collected by our products cannot be used to restore the original fingerprint images and therefore no privacy issues are involved 3 We as the equipment provider shall not be held legally accountable directly or indirectly for any consequences arising due to the use of our products 4 For any dispute involving the human rights or privacy when using our products please contact your employer directly Our fingerprint products for police use or development tools support the collection of the original fingerprint images As for whether such a type of fingerprint collection constitutes an infringement of your privacy please contact the government or the final equipment provider We as the original equipment manufacturer shall not be held legally accountable for any infringement arising thereof The law of the People s Republic of China has the following regulations regarding the perso
50. ion is successful the device prompt Verified 4 If the verification is not successful the device prompt Please try again 10 10 25 Monday 10 10 25 Monday gt User ID 2 Name sun Verify Fingerprint Verify Fingerprint Verified Please try again MENU y MENU 1 1 10 Error Use the Home tab to apply 7 1 to the text that you want to appear here 2 1 1 fingerprint verification In the 1 1 fingerprint verification mode the device compares current fingerprint collected through the fingerprint collector with that in relation to the user ID entered through keyboard Adopt this mode only when it is difficult to recognize the fingerprint 1 Press 1 1 on the screen or 1 1 keyboard to enter the 1 1 fingerprint recognition mode 2 Enter user ID and then press the Fingerprint icon to enter 1 1 fingerprint recognition mode If the prompt Unregistered user is displayed the user ID is not exist 3 Press your finger on the fingerprint collector by 10 10 25 Monday gt Check In adopting the proper finger placement For details see 1 3 Finger Placement 4 If the verification is successful the device prompt Verified otherwise the device prompt Please try again Please input user ID Tees Monday gt User ID 2 Name sun Verify 1 1 FP Match Verified 10 10 25 Monday User ID 2 Verify 1 1 FP Match Please try again 1 1
51. is as shown below Press Save to save current information and return to previous interface press Exit to directly return to previous interface without saving current information Add User Add User Photo User Access 28 Error Use the Home tab to apply 7 1 to the text that you want to appear here 3 8 Enroll Photos If you have enrolled your photo in the system the Add User system will display your enrolled photo in addition to your ID and name after you pass the verification 1 Press Photo on the Add User interface to display the photo enrollment interface 2 On the photo enrollment interface stand naturally in front of the screen For details see 1 1 Standing Position Posture and Face Expression Press Capture to capture the photo 3 After taking the photo press Exit to return to previous interface 4 After the photo is taken press Save to save current information and return to previous interface press Exit to directly return to previous interface without saving current information Add User 4 Exit Capture f Done 29 MultiBio700 User Manual 1 0 3 9 User Access Setting Press User Access on the a Add User interface to display ED SAEN a the user access setting VerType interface li Time Zone la Group Set EA Time Zone 1 0 User Access setting is to set the user right to verify and open the Time Zone 3 0 door Including Verify Type Time
52. ise it will produce alarm signal during Normal close Time Zone or Normal open Time Zone 2 If the normally open or normally closed Time Zone is not defined yet the time the equipment will prompt that you define the Time Zone and transferred to the Time Zone interface to adding 70 Error Use the Home tab to apply jx 1 to the text that you want to appear here 6 7 6 Duress alarm parameter There is duress alarm parameter setting in the device When employee come across duress select duress alarm mode the device will open the door as usual But the alarm signal will be sent to the alarm 1 1 Trigger if select Yes when user use 1 1 match mode alarm signal will come out Or there is no alarm signal 1 N Trigger if select Yes when user use 1 N match mode alarm signal will come out Or there is no alarm signal Password Trigger If select Yes when user use Duress Alarm Parameter 1 1 Trigger gt NO 1 N Trigger gt NO Password Trigger gt NO Alarm Delay 10 password verification mode alarm signal will come out Or there is no alarm signal Alarm Delay After duress alarm gets started the alarm signal is not output directly But it can be defined After some time alarm signal will be generated automatically 0 255 seconds 71 MultiBio700 User Manual 1 0 6 7 7 Anti Pass back setting Set the device Anti Pass back function Anti Passback Setting APB Direction There are four
53. mation Add a Holiday Holiday Set Code 01 01 01 01 01 Start Date 1 End Date 01 Time Zone 62 Error Use the Home tab to apply 5 1 to the text that you want to appear here 2 Edit holiday Select the holiday to be edit and enter the edit interface The edit operation is similar to add holiday After edit press Save to save and return to previous interface 42 Notice If holiday access control time is set user s open door time zone during holiday subject to the time zone here 3 Delete holiday Select the holiday to be deleted Press Delete to popup the confirm interface as follows Select Yes to delete this holiday otherwise select No to cancel the operation Edit a Holiday Code 1 Start Date ppp End Date i 01 Time Zone S Exit l Delete Save L Edit a Holiday Code 1 Start Date 01 01 End Date 01 01 Time Zone 0 Are You Sure 63 MultiBio700 User Manual 1 0 6 7 3 Group time zone setting Grouping is to manage employees in groups Employee oe in groups use group time zone by default Group Y members can also set user time zone Every group can 01 00 00 hold there time zones The new enrolled user belongs to stasis Group 1 by default and can also be allocated to other E groups 1 Add group time zone 1 Enter the Add Group interface press the key to edit Add Group the items Code 2 Code Enter the number edit interface to
54. n customize the function of each shortcut key For details see 6 6 Keyboard Definitions Time Current time is displayed Both the 12 hour and 24 hour time systems are supported dAttendance Status Current attendance status is displayed Fingerprint Image When the fingerprint image is displayed the device is Error Use the Home tab to apply Fx 1 to the text that you want to appear here currently in the fingerprint recognition mode 1 1 Switch Key By pressing this key you can switch to the 1 1 verification modes and enter the digital input interface The function is same to 1 1 Switch Button Menu You can enter the main menu by touching this key SDoor Bell For guest to ring the bell and ask for opening the door Q 1 1 Switch Button You can enter the digital input interface of 1 1 verification mode Error Use the Home tab to apply 7 1 to the text that you want to appear here 1 8 Verification Modes 1 8 1 Fingerprint Verification 1 1 N fingerprint verification 10 10 25 Monday D In the fingerprint verification mode the device compares am current fingerprint collected by the fingerprint collector with all fingerprint data on the device 1 The default main interface is the fingerprint verification Check In mode see the figure on the right 2 Press your finger on the fingerprint collector by adopting the proper finger placement For details see 1 3 Finger Placement 3 If the verificat
55. nal freedom 1 Unlawful arrest detention or search of citizens of the People s Republic of China is prohibited infringement of individual privacy is prohibited 2 The personal dignity of citizens of the People s Republic of China is inviolable 96 Error Use the Home tab to apply jx 1 to the text that you want to appear here 3 The home of citizens of the People s Republic of China is inviolable 4 The freedom and privacy of correspondence of citizens of the People s Republic of China are protected by law At last we stress once again that biometrics as an advanced recognition technology will be applied in a lot of sectors including e commerce banking insurance and legal affairs Every year people around the globe suffer from great loss due to the insecurity of passwords The biometric products actually provide adequate protection for your identity under a high security environment 97 Bata Fa BH Appendix 7 Environment Friendly Use Description The Environment Friendly Use Period EFUP marked on this product refers to the safety period of time in which the product is used under the conditions specified in the product instructions without leakage of noxious and harmful substances The EFUP of this product does not cover the consumable parts that need to be replaced on a regular basis such as batteries and so on The EFUP of batteries is 5 years Names and Concentration of Toxic and Hazardous Substances or Elements Toxic
56. of the cross at five locations on the screen correctly When the message Calibrating screen pls wait is displayed on screen the calibration succeeds and the system automatically returns to the main menu If the calibration fails the system will request recalibration starting from Step 3 81 Error Use the Home tab to apply 7 1 to the text that you want to appear here 10 USB Disk Management Through the Dn Upload menu you can import user information and attendance data stored in a USB disk to related software or other fingerprint recognition equipment Dn Upload de n A Ri or Download Transactions Add User User Mgt Comm Download User E Download user photos an Ee Upload User Data Mgt Date Time Upload User Photo Auto Test Exit N Exit 1 Download Transactions Import all the attendance data from the device to a USB disk 2 Download User Import all the user information fingerprints and face images from the device to a USB disk 3 Download user photos Import the employees photos from the device to a USB disk 4 Upload User Upload the user information fingerprints and face images stored in a USB disk to the device 5 Upload User Photo Upload the JPG documents that are named after the user IDs and stored in a USB disk to the device so that user photos can be displayed after the employees pass the verification See Appendix 3 Photo ID Function 82 Error U
57. options None APB Out PP APB In APB Out In Local Status Exit Control Device Status There are three options Exit Control Entry Control and none Anti Pass back function please refer to Appendix 5 Anti Pass back Anti Pass back setting operation 1 Enter Anti Pass back setting interface press the key to edit the items 2 Press the touch screen number key to set the value after setting press OK to save and press X for exit and return to previous interface 3 Press Save to save current information and return to previous interface press Exit to directly return to previous interface without saving current information APB Direction Local Status APB Out Entry Control APB In None gt APB Outfin Kk Exit 72 Error Use the Home tab to apply jx 1 to the text that you want to appear here 6 8 Update You can upgrade the firmware program of the device by Update using the upgrade file in the USB disk through this function Firmware Version Yer 8 0 0 build 150 Ins USB disk press if ready lt Exit If you need the firmware upgrade file please contact our technical support personnel Generally the firmware upgrade is not recommended a a e ei Bi ei ei ei ei MP eB BP MBP MP MP BP MP BP BP BMP BM BMP BP BM BM BM BP BP BP BP BM BM BM BM BM BM BM BM BM BM BM BM BM BM BM BM Bw BP BP BM BM Bw eS WK 73 1 I I l eee Error Use the Home tab to
58. ormance due to improper i user operations We shall reserve the right of final interpretation and revision of this document l A e e ewe eg Hg a e e ee Bi l l ei eB eB MP MP eM MP eM MP MP eM MP MP BM MBM MP eM BM BM BM eM BM MP BM BM BM BM BM BM BM BM BM BM BM U BM BM BM Bw BM BM Bw Bw UM a P MultiBio700 User Manual 1 0 1 4 Use of Touch Screen Touch the screen with one of your fingertips or the top of the forward edge of a fingernail as shown in the following figure A broad point of contact may lead to inaccurate pointing When the touch screen is less sensitive to the touch you can perform screen calibration through menu operations Press Menu gt Auto Test gt Calibration on the screen and a cross icon will be displayed After you touch the center of the cross at five locations on the screen correctly the system automatically returns to the main menu Press Exit to return to the initial interface For details see the description in 9 Auto Test Smear or dust on the touch screen may affect the performance of the touch screen Therefore try to keep the screen clean and dust free Error Use the Home tab to apply 7 1 to the text that you want to appear here 1 5 Touch Operations 1 Enter numbers Press the Add User Please input user ID User ID key The system automatically displays the number input interface After entering the user ID press OK
59. osantos 34 A E OR 35 4 2 DELETE A USER ora E cia 36 ES QUERY AU SER ca 37 COMMUNICATION SETTINGS ccoococcccccoonocccccoononocccooononccccooooooccccoooooocooos 38 NETWORK SETTING aa wens ctdeaaniteaaneatedeatesvvarciae memiman NA 39 5 2 WIEGAND OUTPUT eerie sien A iaa 41 5 2 1 Wiegand 26 bits Output DesScriptiOD ooooocconoccconoccnnnannonnnnos 42 5 2 2 Wiegand 34 bits Output DesScriptiQD ooooooconoccconcncnnnancnnnonos 44 5 23 Customized FORMO isis lidia 46 Sa WIEGAND INPUT a E E E oa 50 SYSTEM CONFIGURATION 6 ccssccccssssscccssscssccccssscscccsesssssccscesscsceeees 51 6 1 GENERAL PARAMETERS el ada 52 0 2 INTERFACE PARAMETER Sorp ieda aeae E EA OA EROA 53 6 3 FINGERPRINT PARAMETER Sia 54 64 FACE PARAMETER adas 56 OI LOG SETTINGS pieren PR A A 58 6 0 KEYBOARD DEFINITIONS S onaniar id 59 O 7 ACCESS ENG A A 60 OLA Tine zope Seting rr E tase eee 61 07 2 HONDAY SeN tenia 62 6 7 3 Group time zone SEUA ai 64 6 7 4 Unlock Combination Setting ooooonnnnocncnoonccnaanccnnanonananona nacos 67 6 7 5 Access control paraMeter oooooooonncconcnoocnnonaornnnnnarnnnnnarnn nora nn nccnnnos 69 6 7 6 Duress alarm paraMeler coooooconococcconocnccooonnncnonnnnonononoconnnncnnnannncnnnss 71 I Table of Contents 6 7 7 ANU P ASS back SAM ed 72 A EEEIEE EEEE IE EEN O EAEI E 73 7 DATA MANAGEMENT E id 74 8 DATE TIME SETTING 2 2002 cccccsssccccccsccccccccccc
60. part from having all the privileges granted to ordinary users Photo Enroll a user s photo During user verification the user s photo Is displayed on screen q a of i oi User Mgt Comm Auto Test Dn Upload Sys Info lt Exit A Add User PFingerprint Password User Access Set the lock control and access control parameters 19 MultiBio700 User Manual 1 0 3 1 Entering a User ID The device automatically allocates an ID starting from 1 for every user in sequence If you use the ID allocated by the device you may skip this section 1 Press User ID on the Add User interface to display the user ID management interface Tip The user ID can be modified during initial enrollment but once enrolled it cannot be modified 2 On the displayed keyboard interface enter a user ID and press OK If a prompt message The user ID already exists is displayed enter another ID 42 Tip The device supports 1 to 9 digits user IDs by default If you need to extend the length of current user ID numbers please consult our commercial representatives or fore sale technical support personnel 3 After the user ID is entered press Save to save current information and return to the previous interface Press Exit to return to the previous interface without saving current information Add User Group No 1 ho Role User Photo User ccess Please input user ID 4 A Wi
61. return to the main interface if the verification is not passed within 20 seconds 10 10 25 Monday SS 10 10 25 Monday Score 72 gt Check In User ID 2 Name sun Verify 1 1 Face Verified Otherwise the FACE amp FP combination verification can perform such as FACE 1 N FP PIN FACE 1 1 FP PIN FP 1 1 FACE etc The operation is similar to the procedure introduced before 16 Error Use the Home tab to apply 7 1 to the text that you want to appear here 2 Main Menu There are two types of rights respectively granted to two types of users the Ordinary users and administrators Ordinary users are only granted the rights of face fingerprint password or card verification while administrators are granted the access to the main menu for various operations apart from having all the privileges granted to ordinary users Press Menu on the initial interface to access the main menu as shown in the following figure 10 10 25 Monday YT Add User User Mgt Comm SL Im Data Mgt Date Time Sy Auto Test Dn Upload Sys Info Check In The main menu includes nine submenus Add User Through this submenu you can add a new user and input the information on the device including the user ID name fingerprint face card password rights group No and user access User Mgt Through this submenu you can browse the user information stored on the device including the user ID name fingerprint f
62. se the Home tab to apply 7 1 to the text that you want to appear here 11 System Information You can check the storage status as well as version information of the device through the System Information option Records The number of enrolled users administrators and passwords Is displayed on the Records interface the total fingerprint storage capacity and occupied capacity as well as the total attendance storage capacity and occupied capacity are graphically displayed respectively Device The device name serial number version information vendor and date of manufacture are displayed on the Device interface Records Device Name Device Y Add User OS User Mgt Comm Lg Ho Data Mgt Date Time ram gt Auto Test Exit A DnjUpload Sys Serial Number 452161244400 MAC Address 00 17 61 7f 2d 97 Record 100000 Used 91 Free 99909 FP 1500 Vendor Used 10 Face 200 Free 1490 Manu Time Used 9 Free 191 lt Exit Device a lt Records FP Algorithm Finger X10 0 Face Algorithm Face X5 5 Firmware Yer Yer 8 0 0 build 150 2010 09 26 16 01 83 Error Use the Home tab to apply 7 1 to the text that you want to appear here 12 Appendix Appendix 1 T9 Input Instructions The Device supports the input Add User of English characters numbers and symbols Press related button to input text For example press Name to display the text input interface
63. ssword and modify the management rights and group No For example Change the user right from Administrator to ordinary user As the figure shown below User Info User Info User ID 201 User ID 201 a a 35 MultiBio700 User Manual 1 0 4 2 Delete a User On the User Info interface you can delete all or partial user information 1 Press Delete to delete a user 2 On the interface displayed click YES to delete current user and NO to return to previous interface 3 On the User Info interface press Name Fingerprint Face or Password to delete related user information and re enroll the new information follow the device prompt User Info User Info User ID 201 User ID 14 SRN CP 36 Error Use the Home tab to apply jx 1 to the text that you want to appear here 4 3 Query a User To facilitate administrators to locate a user quickly from ci a large number of enrolled users the Device enables user query by his her User ID User ID Query 1 Press Query on the User Management interface to display the User ID query interface 2 Enter the user ID on the displayed interface and click OK to locate the cursor to the desired user Please input user ID 4 7 37 Error Use the Home tab to apply 7 1 to the text that you want to appear here 5 Communication Settings You can set related parameters for the communication between the Device and
64. t if the state Auto Switch value the interface shown as figure above 4 Press Save to save the modification and exit 59 MultiBio700 User Manual 1 0 6 7 Access Setting Access control setting is to set user s open door time zone control lock and related device s parameters To unlock the enrolled user must accord with the following conditions 1 The current unlock time should be in the effective time of user time zone or group zone 2 The group where user is must be in access control or in the same access control with other group to open the door together The system default the new enrolled user as the first group default group time zone as 1 access control as Access Control Set Time Zone Set Holiday Set Group Settings Unlock Combination Setting lt Exit Xx 4 Access Control Parameters Duress Alarm Parameter Anti Passback Setting the first group and the new enrolled user is in unlock if user has modified the related setting of access control the system will be changed with user s modification 60 Error Use the Home tab to apply jx 1 to the text that you want to appear here 6 7 1 Time zone setting Time zone is the minimum unit of access control option Add a Time Zone The whole system can define 50 time zones Every time Code 4 zone defines seven time sections namely a week Sunday 00 00 23 59 23 59 23 59 23 59 Every time se
65. t template enrolled in the Device is larger than this threshold the matching is successful otherwise the matching is not successful The recommended thresholds are as follows Threshold FRR FAR 1 N 1 1 High Low 45 25 Medium Medium 35 15 Low High 25 10 Algorithm Version This parameter is used to select the fingerprint algorithm version between 9 0 and 10 0 Please select the algorithm version with caution because the fingerprint templates of these two algorithm versions are incompatible Fingerprint Image This parameter is used to set whether to display the fingerprint image on the screen during fingerprint enrollment or comparison It has four values Show For Enroll Display the fingerprint on the screen in enrolling process Show For Match Display the fingerprint on the screen in verification process 54 Error Use the Home tab to apply jx 1 to the text that you want to appear here Always Show Display the fingerprint on the screen in enrolling and verifying process Never Show Never display the fingerprint on the screen in any case 55 MultiBio700 User Manual 1 0 6 4 Face Parameters 1 1 Threshold This parameter is used to set the threshold of matching between current face and the face template enrolled in the Device in the 1 1 verification MARISCO mode If the similarity between current face and the face PAID Exposure template enrolled in the Device is larger than this Gain threshold the m
66. talia aia See ae i i i i I i i Vol Zo A Y AAA ala a o UV mn it i i 5V ata OS Sig es re reen Wire Wii ee E av gt RRA AE PS SI E RA RE Te ae 1v ov Lo Tai Tow pie Tot al Table Pulse Time Symbol Typical Value of Reader Tpw Pulse Width 100 us 87 MultiBio700 User Manual 1 0 Appendix 3 Photo ID Function Some Devices also support the Photo ID function The 10 10 25 Monday Photo ID function is used to display the photo enrolled by a user or stored in a USB disk on the screen in addition to such information as the user ID and name Operation Steps 1 When the photo taken by the device is used the photo can be displayed upon successful verification e 2 To use a photo stored in a USB disk proceed as MEAT follows Verify Password Verified 1 Create a folder with the name of photo in the USB disk and store users photos under this folder 2 The user photos must be in JPG format and named after their IDs For example for the user with user ID of 154 the photo name must be 154 jpg 3 Insert the USB disk into USB slot on the device and select USB Disk Management gt Upload gt Upload Photos Then user photos can be displayed upon successful verification SF Note 1 The length of a user name cannot exceed 24 digits 2 The recommended size of a user photo is less than 30kbit 3 The uploaded new user photo will overwrite t
67. the Device 3 If the card passes the verification the Device displays k Card a prompt message Read Successfully Card No EEE and returns to the Add User interface 4 Press Save to save current information and return to the previous interface Press Exit to return to the ammm m len coe Delete Save previous interface without saving current information Enroll Card Enroll Card User Info User ID 201 us nas Punch Card y 7 33 Error Use the Home tab to apply 7 1 to the text that you want to appear here 4 User Management Browse the user information including the user ID ee nr name fingerprint face ID card password rights group Y No and user access settings To add edit or delete the basic information of users Press User Management on the main menu interface to display the user management interface The user is an administrator smith CICR 42 Note The users are listed in alphabetical order by last name If you select a user you can access the editing interface of this user to edit or delete related user information 34 Error Use the Home tab to apply 7 1 to the text that you want to appear here 4 1 Edit a User Select a user from the list to enter User Info interface The User ID cannot be modified and the other operations are similar to those performed to add a user You can re enroll your fingerprint and face image change your pa
Download Pdf Manuals
Related Search
Related Contents
Mode d`emploi du Back Gym Kensington K39558WW mobile phone case Accuview OFU150G Copyright © All rights reserved.
Failed to retrieve file