1. a standard AVI file INFINITY ANALYZE Changes to the Layout e On initial start up of the software the first time user will be presented with ANALYZE shown in a simple configuration e New options to quickly modify the application layout are provided as Simple Mode and Enable All available from the View Menu e Anew Full Screen display function has been added This feature allocates the maximum amount of the display for either the live preview or for captured images The application can switch in and out of Full Screen mode by using the View menu or with a simple press on the lt Esc gt key e The contrast of the status bar has been improved by making the background color black Some toolbar icons used for image positioning have been removed to reduce clutter These seldom used navigation functions are now accessible only from the View menu as items labelled as Center and Corner The Field Menu entry formerly labelled as Vector Arithmetic has been changed to Math The buttons labelled Video On Off have been removed from the Capture Control panel providing more space The sequence of Control panels from top to bottom has been rearranged for greater ease of use The Measure Menu has undergone a transformation to make the most commonly used options readily accessible and to improve the ease of use for common measurement tasks The Calibration and Micrometer functions have been moved onto this menu Revisions to the Micrometer
2. easily defined A new tool allows for the operator to specify the grid parameters using the cursor position on the captured image e tis now possible to change the units of measurement without re calibrating e Anew auxiliary window called Photometry has been added to ANALYZE It reports pixel intensity values for any defined measurement areas
3. function allow the bar and the text to be re positioned anywhere on the image by placing them in the annotation layer The distance or length measurements tool formerly labelled as Caliper has been changed to Point to Point A new option has been added to the File menu called Close All Images This feature pops up a single confirmation dialog prior to closing down all displayed images in the working area Warnings and information messages now alert the operator when the Field Group memory is consumed or if the number of fields have been used Camera performance and controls The Camera Control panel now includes a new option to provide a Continuous Auto Exposure function In previous revisions of the ANALYZE package the live preview from certain high resolution camera models notably the INFINITY2 3 INFINITY1 5 and INFINITY4 11 would often produce a grid pattern appearance that varied based on the display window dimensions While this artefact was observed only in the live preview and not on captured images it was an undesirable characteristic Modifications have been made to the display capabilities to help eliminate or minimize this problem Other functional changes A Bitmap Overlay function has been added to both the Live Preview display and to Captured images This function is accessed using the File Menu gt Bitmap Overlay The newly designed Grid Options function allows for the origin and size of the grid spacing to be
4. quality of Brightness Contrast and Gamma in 16 bit mode INFINITY ANALYZE e ANALYZE Settings files have been relocated to the standard Windows folder location for Application Data providing better compatibility with future releases of the O S This new location will be different on XP and VISTA platforms For XP Drive Documents and Settings All Users Application Data INFINITY ANALYZE For VISTA Drive ProgramData INFINITY ANALYZE Settings e A problem has been rectified with saving of new camera Presets The original release of INFINITY 5 0 introduced a problem resulting in ANALYZE failing to store the camera white balance settings When a Preset was restored the appropriate color gains were not being set on the camera e An incorrectly imposed restriction on number of decimal places allowed in the Measure Options dialog has been removed Entry of any value less than 2 was not permitted in the first releases of the 5 0 version e An enhancement has been added to the micrometer bar placement allowing the previously selected location to be used again in the current image The option is presented in the pop up dialog after using the mouse to select a location in the image This allows for the micrometer bar to easily be placed in a consistent location on all images if desired e ltalian language files have been added to the installation and the additional entry may now be selected from the View gt Language menu option e The
5. ANALYZE Advanced Features USB Key is now being distributed as a driver less device making for a simpler installation supported across more O S platforms The Release 5 0 2 of INFINITY ANALYZE is required to take advantage of this new style of USB key Includes a correction to the driver for the INFINITY1 3 model This patch release is identical to the 5 0 0 release in all respects for INFINITY Capture and ANALYZE applications Release Highlights The following list summarizes the highlights for this 5 0 0 release Details can be found below with even more information available in the Release Notes and the product documentation 64 bit drivers are now available for all INFINITY cameras on Windows platforms ANALYZE now includes a FULL SCREEN mode Preview grid pattern artefacts have been eliminated from ANALYZE Bitmap Overlay added to Live Preview and Captured images in ANALYZE CAPTURE can now export camera settings to a named ANALYZE preset ANALYZE now offers a Simple layout for demos and first time operators Camera Drivers e Added support for 64 bit Windows XP and Windows Vista operating systems e All drivers are digitally signed for Windows Vista operating systems e Added support for new revision of INFINITY2 2 cameras INFINITY CAPTURE e New function to export current camera settings into an INFINITY ANALYZE preset e Added additional 75 zoom mode to preview zoom control e Improved AVI filenames when converting a RAW AVI file to
6. INFINITY Software v6 0 0 What s New The following list summarizes the highlights for this 6 0 0 release This release incorporates improvements to the installation package device driver updates and some nice additions to the INFINITY ANALYZE package The locations of some application related files have been altered to better accommodate Windows 7 and VISTA permissions Camera Device Drivers Improvements to the INFINITY1 2CB exposure controls to allow this framerate centric camera to respond more like an exposure centric camera INFINITY Capture amp TWAIN interface Changed location of Last Settings file to overcome write protection issues On VISTA amp Windows 7 C Program Data Twain_32 INFINITY On Windows XP C Documents and Settings All Users Application Data TWAIN_32 INFINITY INFINITY ANALYZE Now includes dynamic window zoom for both live preview and captured images New Cell Counting menu item available on the Measure menu allows for interactive thresholding and quantitative results based on pixel intensities The image title bar is updated with the image file name as soon as it has been saved Micrometer bar text and length are now associated to the active calibration User Manual has been fully updated to reflect all menus and dialogs User interface is now available in 7 different languages Help menu provides direct access to video tutorials available on the Lumenera website New Annotation menu item crea
7. tes a bitmap overlay image from displayed graphics All auxiliary windows and toolbars can be interactively enabled disabled from the Help gt Settings dialog on a new tab Photometry auxiliary window displays pixel intensity distribution for measured areas The camera presets file containing calibrations is now located in this folder location On VISTA amp Windows 7 C users User Name AppData Roaming INFINITY ANALYZE On Windows XP C Documents and Settings User Name Application Data INFINITY ANALYZE KNOWN ISSUES e Frame rate of the INFINITY1 2CB is limited to 10fps but can be extended to 15fps in INFINITY Capture although vertical bands may be visible and impact image quality e Frame rate of the INFINITY1 2CB is limited to 5fps in INFINITY ANALYZE but will be increased in a subsequent release e INFINITY ANALYZE does not currently take advantage of the modified exposure centric behavior that has been implemented for the INFINITY1 2CB camera and included with INFINITY Capture This will be addressed in a subsequent release The following list summarizes the highlights for this 5 0 6 release INFINITY ANALYZE e Added the default previewing video mode for the INFINITY2 5 camera Camera Drivers e Improvement of the exposure and gain properties control The following list summarizes the highlights for this 5 0 5 release Camera Drivers e Added support for the new INFINITYLiteB cameras e Improve s
8. upport for the new INFINITY1 2B cameras The following list summarizes the highlights for this 5 0 4 release Camera Drivers Added support for the new INFINITY4 11 cameras Added support for the new INFINITY2 5 cameras Added support for the new INFINITY1 2B cameras using the SOI image sensor Upgrade to new API version 2 1 0 241 e Improve Windows 7 support This section describes all the additions and updates we have made to the latest release of the software Camera Drivers e Added CIM3 support for INFINITY2 1 and INFINITY2 2 cameras The following list summarizes the highlights for this 5 0 2 release Installation and Camera Drivers e The installation process has been revised to include a screen prompting for the INFINITY camera to be disconnected from the PC prior to continuing e New driver file updates are included to correct an issue with the INFINTY4 11 and Lw11057 SCI models that could result in corruption of the live video preview Currently does not support external signaling of start of frame in Video mode GPO4 Video SoF e Corrected an issue where pixels would not fully saturate at default gain for the INFINITY1 5 model In addition the following Still Mode properties have been enabled STILL_EXPOSURE STILL_GAIN STILL_GAIN_RED STILL_GAIN_GREEN1 STILL_GAIN_GREEN2 STILL_GAIN_BLUE STILL_STROBE_DURATION e Corrected issue for the INFINITY4 Lu330 camera models with driver signing for Windows Vista Also improved

Download Pdf Manuals

image

Related Search

Related Contents

Targus 10.2 Crave Netbook Case  Philips SMARTSPOT Recessed spot light 57971/17/16  ViewSonic VS13191 User's Manual  Rio LAHR2 light depilation  EMA&EMB Series servo drive - China EM Technology Limited  衛星通信車調達仕様書(PDF形式)  8 Radiation des cadres pour abandon de poste  純 - あかりの日  pharos - Growers Supply    