Home

前 言 - SIPVE TM On Line!

image

Contents

1. Off duty2 Work long Stat rule Minutes calculated as a workday 480 Minutes after On duty calculated as late 5 Minutes before Off duty calculated as early 5 Minutes calculated as late if mo clock in 60 Minutes calculated as early if no clock out 60 Minutes after Off duty calculated as overtime 60 v Work time in day off calculated as overtime Save 4 2 1 Workday setting Workday is managed by week cycles easily to set which day is workday and which day is rest day You only need to select the corresponding workday and all setting will be done simply 4 2 2 Holiday setting Click Holiday setting option following window pops up j amp Holiday setting Holiday information Holiday name National Day Add Starting date 200910 1 e Day 18 Del Holiday name Starting date Day National Day 2009 10 01 Add holiday Enter holiday name starting date days and click Add to complete Delete holiday Select the holiday record from holiday list and click Del to complete 4 2 3 Work time setting The setting of work time can be in two time ranges of AM and PM as well as in one time range which can be done according to the real requirements of different companies 18 Please note If there s no work time setting the time attendance reports will not have the calculation of item coming late leaving early working overtime absent from work it 19 Will only calculate th
2. Ze WISE DO NIN ia 6 a OO 6 2 2 4 Management Password SettiNQ cccccccccccooncccnnncconnnonnnnnononononnnnnnnnnnnos 6 29 e ee pe bina 7 System Instala ost teoria 9 3T Operation ENVION ti td id iia 9 e SysteminsialaioN it ii aA DES 9 323 Wrnstalihe roda a dl a 12 Data cCOMMUNIC AMO Mati ridad dd 14 A SAC Oena 14 4 1 1 Department ManageMent ccccsseccccseeeceseeeeeseeeeeseeeecseeeeesaeeeesaaeees 15 412 AMS MAN ss 16 4 1 3 Import Staffer s Information ooocccccnncccccconnccnnnccnononncnnnnonononanenononcnos 17 42 ABASIC GConiguralo Mers ar did 17 AZ Workday SOU cai bai 18 42 2 TAOIGAY Seting unre en he rn eee ed rem seca ahaa eh nel 18 AZO Work tlmMe SetIN ii dida 18 Pm Er ee 19 4 3 T amp A Management cccccseccccssscecceeeeecsseecseseeeseueeecsuseeeseueeessaueeesseseeesaeees 20 431 Forget management oari cake hee a 20 4 3 2 Leave ManageMeNtooccncccnnnncconcnnoconnncnnnconononnnnononnnconananononrnronannnconananenanens 20 A RODO Eee A FEE FRELSE TRE en ete ree 20 4 4 Communication Management cccccccssescccccceessseeeecceeessseeeeeeeeeeeessaeaeeseeeess 21 A A A 25 O A A A IA 25 5 1 1 Fingerprint has been enrolled but often gets failure in identification 25 5 1 2 No records found though staff have clocked in oUt cccccocccccconcnnco 25 5 1 3 T amp A system can t be connected with PC cccooccccccccccccconnncconcncccononononons 25 5 1 4 Time is wor
3. progam fot aed O Randia inthallshon program fit Witte If you want to install the driver you should select the driver for your PC s operating system and then click Finish to install the driver For example Run driver installation program for Windows XP then the driver installs wizard window pop up 10 Mi 23039 Baer Imdaller Program j Welcome bo the linet hand Wiraed loa Pl 24 LUSH bo deial The lribalS hd ition eel reta PL O LS oie im yout Gorpuier Tarira k Ned Licente Agreement Ple s re d thet loko oanad aoreereend caret End Uas Lesmap 4agememer BULE Che nef thal owen the sobrio web ou Raed oa ane red all ol fhe hernan heer lem Aceptence will bend you lo the keene Hand ma legal aniics Donia path Probe Tecinology Ine SOFTWARE LICENSE AND UMITED WARRANTY The ii an agreement beheren pou the end uva aed Prode Tachrvobogge be Prolific Bp usng he talee pu agent in become hed Ey the barma cd then agement ge ORESTES of rp bonat apormend Fortis pete Choose I accept the terms of the license agreement button Click Next gt button to install driver After installation completed the following window will show as below Mi 23039 r rer Imdaller Program Install held Wizad Complete The Ingia hiel viand hea pecera installed the PL 2309 WEB boe Sema inser Penas chick the Frish buon ig sat tha watand TP pour Paver plore ha Lo dee on PL before suring thet tiup
4. selected staff to the appointed department 4 1 3 Import Staffer s Information Click Import and a selection window will pop up as following oo E Select the right Excel file which includes staff information and the software will start to import staff information finally the software will prompt the successfully imported staff number and the total staff number after the import completes See the same as following 3 Total Staffers 2 Imported successfully 2 OK Please note The import requires fixed Excel file format The first row should be field information Staff information comes from row 2 The field information of each list should be in such order Staff number name department Tel and Sex Please refer to the following picture Microsolt Excel teriris f B pe pat je pei F rst pa Bee inden ie Ace PF ax E 222 UA LEA RAN T a Iaj RE E E i E F pis Dept 1 SE Adal l A Admir sa moot Wh Sme ET al aif a p 4 2 Basic Configuration Select Basic Configuration page main including workday shift statistic rule setting 17 amp Function management Staff information Basic config TRA Management Comm Management Work day Y Mon 4 Tue v Wed V Thu v Fri Sati sur f Holiday setting Work time On duty1 09 00 Off duty1 17 00 Work long 480 On duty2
5. setting PD KA Language 2 Y Dormancy time vw Match precision General S e Timing reminding a ee Time Syn Clear transaction record Initialize unit Data communiation Download new records Download all records Backup data Restore data Password Modify the management password of the unit Language Modify the language display of the unit which can make the Chinese English languages shift available Dormancy time Modify the dormancy time of the unit Default is 5 minutes Match precision Modify the fingerprint match precision Default is normal Timing reminding Modify the remind time which can set timings needed to remind 5 timings are available Time synchronization Make the date and time of the unit the same with the current date and time of the computer Clear transaction record Clear all time attendance records stored on the machine Initialize unit Restore the machine to factory default Download new records Download new attendance records from the unit that haven t been downloaded to the computer Ag Download all records Download all attendance records from the unit to computer Backup data Download Staff information and Staff fingerprint templates from machine to computers Restore data Upload Staff information and Staff fingerprint templates to the unit While it is communicating with machine t
6. time 3 EB i Ending time 2006 06 21 e 17 00 00 Leave class Business leave El Leave reason Add I Del Report f A Starting date 2006 06 01 S Ending date 2006 06 07 e Stat g 1 m Preview Daily Report Preview General Report Esport to Excel L 2 ait 4 3 1 Forget management First choose the right department and staff then select appropriate date time and clock status and click Add button to complete 4 3 2 Leave management Add leave record First choose the right department and staff then select the starting date time and the ending date time of leave enter leave reasons select leave classes and click Add to complete Delete leave record First choose the right department and staff then select records from list of leave and click Del to complete 4 3 3 Report First choose the right department either one staff or all staff select the starting date and the ending date of calculation click Stat to complete After calculation is done click one of the three buttons of Preview daily report Preview general report Export to Excel to preview the corresponding statistical information Daily report is as following 20 E f US AY Staff Daily T amp A Report Pat 3j General report is as following es f US AY Staff T amp A General Report Pat sj Export to Excel can export staff transaction recor
7. Del Add I Del I Save Clear Add department click Add button under the department list and a window will pop up as following amp Add department Please enter department name Y OK E Cancel Please enter the department name which needs to be added click OK to finish and the newly added department will be displayed in the department list accordingly Prompt the adding department is sub department of selected department Default is sub department of head office Modify department First select the department name which needs to be modified then click the department name and modify department information directly after the cursor appears Delete department First select the department name which needs to be deleted and then click Del button and a confirmation window will pop up as following amp Please confirm 2 Are you sure to delete the selected department OK l Cancel Click OK and the selected department will be deleted accordingly if there s existing staff information in the deleted department all those staff will be transferred to 15 the head office automatically Please note The head office cannot be deleted 4 1 2 Staffers Management Add staff Choose the right department that the staff belongs to click Add button under the staff list enter information of Staff number name sex Tel photo etc then click Save button under staff lis
8. Geese unplay araj en plug Ue cable agan fey piin daethon Click Finish button and exit install interface and an icon will be added to the desktop Double click it and the T amp A management system will be started In addition Bio office Fingerprint Attendance System has been added to All Programs Please see the picture below 11 9 E sofie Fingenieink Atberdlance System The shortcut of Bio office Fingerprint Attendance System is included in All Programs 3 3 Uninstall the program Click Uninstall Bio office Fingerprint Attendance System in the above picture click Next and the program will be uninstalled automatically Please note All the files and data will be deleted after uninstalling the program so please make sure before operation 12 Chapter 4 Communication The chapter is mainly about how to add delete and set communication between PC and terminal 13 4 Data communication The main functions in data management between attendance software and device include user management device parameter setting real time attendance records monitor exception attendance dealing summarize attendance records and generate attendance statistic report Double click shortcut 9 or run attendance management program in Start All programs Bio office Fingerprint Attendance System Fingerprint Attendance System option the main interface is as following a 4 Bio office Time Attendance Managem
9. If green LED indicator is on it means initialization is successful USER REG FINGER 1 Input ID i n yi x IILI Input PW x Caution initialization will resume to leaving factory status which will delete all data saved in device memory Recommend to backup all data including staff info fingerprints and records before this operation ETT System Installation This chapter mainly discusses the installation and un installation of T amp A software as well as the hardware and operation system requirement 3 System Installation First we should install background management software on the computer Please refer to the following steps 3 1 Operation Environment Hardware requirement Pentium Il 266 and above PentiumIII500 and above is recommended 128 Memory and above Minimum 100M hardware space COM USB Port CD ROM CD ROM needed in installation VGA support 800 600 resolution and above Operation system Microsoft Windows 2000 XP Recommended Microsoft Windows Vista 3 2 System Installation Please insert T amp A disc into CD ROM and the disc will automatically run the installation program If not please run setup exe in the root directory of the disc The following window will pop up ES Welcome lo Dile Finger ltendance Sucker Setup progre This pogam wall naal Diceotice Fingerprint hernan e Cpm om pour e Be iron tected id pos al all Arat prisa bala narra the Seti Frog C
10. Preface Honorable customers Thanks for choosing products of our company The product with world cutting edge technologies fingerprint recognition computer communication as well as microelectronics is considered to be combination of three technologies electronics optics and computer communication It is no doubt that it has become the first choice of standalone time attendance for enterprises with its strong function and veracity New generation BioNano fingerprint identification algorithm which undergoes researching for 10 years with TI 300MHz high speed processor all self owned intellectual property rights unique function of healing the broken fingerprint lines and intelligent fingerprint template update is one of the most efficient and stable fingerprint algorithm in the world Bio office is a sub brand of Anviz USA Bio office series fingerprint products combine fingerprint and traditional RFID technology All models come with powerful background time attendance management software which can support all kinds of complicated shift and generate various reports It is versatile convenient and multi functional Please read this user manual carefully to have an initial understanding of functions and basic knowledge of installation debugging maintenance application and management to better use this product Advantage of Fingerprint Time Attendance e Three level up 1 Management level up 2 Profit level up 3 Enterprise i
11. acking e Standard USB RS485 communication Plug and play Easy installation and operation e Inbuilt high capacity 1000mAH Li ion battery e Identification method ID password ID fingerprint fingerprint only e Fingerprint capacity 1500 Record capacity 32000 e Size 157mm W x 119mm H x 35mm D ETICA Operation Guide This chapter is mainly about appearance illustration and relevant system settings such as how to add and delete users etc 2 Operation Guide 2 1 Key Introduction fi N fe eS AR A AN AN OUT gt M 4 3 i Ree y lr y A ET Y SY a 5 S 7 DN UW e 2 Ey lt N Y Re y 4 JS y S Vd 6 Sa g N Y NS Y WY w TC200 Keypad Key introduction 1 IN OUT In Out convert key 2 0 9 Number key 3 gt Option convert key 4 M Menu Key 5 C Esc Cancel key 6 OK Power OK Key 2 2 Management Mode Press firstly enter the original password 9999 and press to enter into user enrollment status As follows Input Password x In operation mode the default is user registration interface Enable to do user registration deletion time setting and password management through M key 2 2 1 User Registration Systems will auto start with default ID Such as 0001 Enter new ID i e 1082 pr
12. as the corresponding late minutes If the check box is not selected calculation of no clock in will be treated as absence from work Deal with no clock out while off duty If check box before minutes calculated as early if no clock out is selected calculation for no clock out will be counted as the corresponding early minutes If the check box is not selected calculation of no clock out will be treated as absence from work Minutes after off duty calculated as overtime Calculation unit is minute This option won t be valid until the work time is set successfully If it is set to 60 minutes and off duty time is set to 17 00 the records after 18 00 will be counted as overtime work records If the off duty punching is 18 20 the calculation will be counted as overtime work for 80 minutes Work time in day off calculated as overtime If this option is selected work time on 19 day off will be counted as overtime work time 43 T amp A Management Select T amp A Management page main including dealing with forgetting punch in out asking for leave and report statistic amp Function management Staff information Basic config T amp A Management Comm Management artment Headquarter 8 Staff Al M Forget Management Time 2006 06 21 e oe 00 00 e staus Onduy e Add Leave Management Starting time 2006 06 21 08 00 00 Staring time Ending
13. ds daily T amp A reports T amp A general reports and reports of business leave leave to Excel files 4 4 Communication Management If connection between unit and software is unsuccessful it will pop up connection window as following GR amp Connect Connection information fe USB gt RS485 com L vox Before connection please check if the hardware cable connection is ok and if the unit is working normally And then setup connection as above picture select the right Com and click OK If COM is incorrect or the selected Com is occupied the program will prompt Open com port fail If the machine cannot be connected the program will al prompt Connect to the machine overtime Please note If the connection between unit and software is successful the connection window will not pop up again If the unit is successfully connected unit information will be displayed such as Staff number fingerprint template number attendance record number firmware version and serial number Furthermore function buttons such as Modify password Time Syn Clear Transaction record Initialize unit Download new records Download all records Backup data and Restore data will be activated after successful connection amp Function management Staff information Basic config T Management Comm Management Unit information Staff Template Record Firmware ver SN Unit
14. e overall work time according to time attendance records 4 24 Stat Rule Minutes after on duty calculated as late Calculation unit is minute This option won t be valid until the work time is set successfully If it is set to 5 minutes and the setting of on duty time in the timetable is 09 00 any on duty punch time which is after 09 05 will be calculated as coming late If on duty punch time is 09 08 the calculation will be counted as coming late for 8 minutes Minutes before off duty calculated as early Calculation unit is minute This option won t be valid until the work time is set successfully If it is set to 5 minutes and the setting of off duty time in the timetable is 17 00 any off duty punch time which is before 16 55 will be calculated as leaving early If off duty punch time is 16 52 the calculation will be counted as leaving early for 8 minutes Valid time range for clock in and clock out Calculation unit is minute This option won t be valid until the work time is set successfully If it is set to 60 minutes on duty time is set to 09 00 and off duty time is set to 17 00 the records between 08 00 and 10 00 will be counted as on duty records and records between 16 00 and 18 00 will be counted as off duty records All other records will be counted as invalid records Deal with no clock in while on duty If check box before minutes calculated as late if no clock in is selected calculation for no clock in will be counted
15. ent System 1 0 2006 06 Staff Wed ape 162724 Total 2 Passed 0 Connection success Function lt lt Name Dept The main interface displays the current date time total staff times passed the detail staff information that is the finally passed and whether the connection between unit and computer is successful Clicking Function lt lt button to open Function management as following shows amp Function management Staff information Basic contig T amp A Management Comm Management Department list Staff list a Staff Name IS No Picture The function management interface includes 4 pages Staff information Basic configuration T amp A management and Communication management All management operations of this software will be done through these 4 pages For detail operations please refer to following 4 1 Staff information 14 Choose Staff information page mainly including adding deleting and modifying operation for department and staff 4 1 1 Department Management amp t Function management Staff information Basic config T amp A Management Comm Management Department list Staff list El Head Office Staff Name Staff 8102 wv A amp amp D 8101 King Jin Sale gt Name Brandy Male e Sex Tel 13698632563 p View Add
16. ess to select FP or password option i e the 1 FP USER REG FINGER 1 Input ID y O y INDIE Press Finger Press OK to register FP press finger twice on sensor according to LCD indication lf green LED indicator is on it means registration successfully qa Prompt Press to convert registration option default is the FP registration t d The sequence is 1 the 1 fingerprint 2 the 2 fingerprint 3 Password USER REG FINGER 2 USER REG PW Input ID rl J J Input ID 7 O y IDE IDE Press Finger bl i 2 2 2 User Deletion In management mode press M to choose User deletion menu Input ID no j Enter the user ID to be deleted and press OK to confirm If green LED indicator is on it means deletion successfully 2 2 3 Time Setting In management mode press M to choose Time Use number key to input date time Then press OK to save If green LED indicator is on it means setting is successful 2 2 4 Management Password Setting In management mode press M to choose Setting Input Password x Input new password with 4 digits Press OK to confirm Input password twice according to LCD indication If green LED indicator is on it means registration successfully 2 3 Initialization Enter User Registration interface in management mode input 0000 press OK to confirm and input management password default is 9999
17. hek Cancel to qui Setup ar tota Lara apar ola sunno Cd Mest io continue eth Salus piba WARMING Tha Pa en a protein Ep cdo rl naman h Unai isprduch n on deinbubor of la prayer dl np podran ol ds a pk Cd deed cotter parade al vel be piap be e masa exter E under mA Click Next to continue installation see the picture below E Bin alli r Fingerprint Allende Sabe Destination Location Lo Sebup rel evita Barala Frapar Albencdanos Scher m lha kalca loklar To r tal into a diferent folder click Bienes and taisc arcther holder Mou Can Chante not lo instal Biois Fingerp nt A endance Syitem by checking Cancel ho ak Setup Destination Folder CAnC oo Byret Select the target directory to install the program and the default is C TC200 Click Next to continue installation see the picture below a Rir olli r Fieger print Abb olen Sybe eS Staat Installation O Von ate raye bahe bo rilal BETTS TEE EET SE EESTI Chick e Nes butor lo began thes imelala of e Back button lo psenter the rebellerne information TH Ire allshon Wiad Bek Het Cancel Click Back and installation will return to the previous screen and re select target directory Click Next and the installation will start as the following picture shows Fao ollie Fingerprint Mibendancre Syl eee PTT TTT TTT Try ey E All Files Time Messer minutes 4 seconds OE TO Run diver mialan
18. here will be information prompt in the blank display box moreover there s display of rate of progress while it is processing of Download new records Download all records Backup data Restore data 23 Or TIRA Appendix The main theme of this chapter is the additional information of this T amp A including FAQ interface illustration and way of pressing finger 24 9 Appendix 5 1 FAQ 5 1 1 Fingerprint has been enrolled but often gets failure in identification Reason Solution 1 The fingerprint was not Enroll the finger again Please refer captured properly to illustration of pressing finger 2 Direct sun light or too bright Avoid direct sun light or other bright light light 1 Touch the forehead to increase 3 The finger is too dry wet or oily oily level of the finger 2 Make you finger dry and clean 4 Low fingerprint quality with Enroll other fingers with better callus or peeling quality 5 Wrong way in placing fingers Please refer to illustration of when punching in out pressing finger 6 Latent fingerprint on the Clean sensor surface adhesive surface of sensor tapes recommended Place the finger evenly on the 7 Not enough finger pressure i sensor with moderate pressure 8 Influence by fingerprint image Enroll fingerprint again Please refer change to illustration of pressing finger 5 1 2 No records found though staff have clocked in out Reason Solution 1 Unit power brea
19. k for a long time i l Please refer to synchronize the time time turn to zero as default 2 Records have not download Download records again 3 The records space of device is mn T Clear the records in time u 5 1 3 T amp A system can t be connected with PC Reason Solution 1 Communication method not set Select the correct communication 29 2 Able not plugged firmly or cable Plug the cable firmly or change hardware problem another cable 3 Not able to connect COM Please enter the right COM No wrong COM No 5 1 Time is working fine but scanner is off Staffers can not clock in out 1 Unit in dormancy status Press any key to activate 1 Refer to normally disconnect the device in Communication if 2 1he device is communicating disconnecting not correctly the now or there is cable interference device will recover automatically every minute 2 Eliminate the interference i Restart unit or change the 3 Fingerprint scanner abnormal fingerprint module 5 1 5 The ID Fingerprint mode can t pass 1 Wrong ID entered Enter the right ID 2 This user has no right to use Set permission of 1 1 identification 1 1 identification method method for the user 5 1 6 The unit identifies automatically when no one punches in out Reason Solution 1 Direct sun light or too bright Avoid direct sun light or other bright light light 2 Latent fingerprint on the surface Clean sensor surface adhesive
20. king fine but scanner is off Staffers can not clock in out 26 5 1 5 The ID Fingerprint mode can t paSS cccccconnnnncccnnocnncnonnncnncnonannnncnonanonos 26 5 1 6 The unit identifies automatically when no one punches in out 26 g2 Imenace IST sl ene ner ae tT ete Pee mu 26 5 3 Illustration for pressing fingerpriNt oooccccnocnncocccnnccnncnnnnnnnncnnnnnnononcnnnnannnnnnanos 27 II Chapter 1 Introduction The main theme of this chapter is the feature of this T amp A as well as function introduction 1 Product Introduction 1 1 TC200 Introduction Bio series TC200 fingerprint attendance machine is the first desktop standalone time and attendance produced by this company in 2009 With the use of Anviz optical fingerprint sensor and new fingerprint recognition algorithm TC200 can identify all difficult fingerprints and has solved the long lasting problem in fingerprint recognition field TC200 is a desktop 128x64 blue LCD fingerprint T amp A can be used offline or online TC200 Fingerprint T amp A Machine 1 1 1 Product Feature e Korea professional design unique wall mounted desktop design World super slim e USA TI 300MHz high speed processor e USA BioNano core fingerprint algorithm of high speed and stability e New generation fully sealed waterproof and dustproof fingerprint sensor e Musical timing alarm function e Real time data transfer and WEB online tr
21. mage level up e Three reductions 1 Employee dispute reduction 2 Work redundancy reduction 3 Environmental pollution reduction e Three eliminations 1 Buddy punching elimination 2 Loss and damage elimination 3 Circular cost elimination e Full function The system can realize different functions such as attendance remark calculation and report printing The remark can be made for reasons such as business leave absence marriage holiday and etc the checking and calculation can be made in accordance with different time periods departments individual or combination due to various reasons for absence the report generation and printing function can be realized perfectly e Flexible Shift Maintenance The software supports shift on week basis rotation shifts etc Various shifts public holidays individual leave and overtime are available to meet the complicated needs of every enterprise e Standalone The machine can work without connecting to PC convenient in operation and no need to occupy any extra resource e Multi communication in network For large enterprise multiple devices can be applied to do attendance synchronously which will convenient for large quantity of users and save time Contents ProdUCEINTOdUCHON creenin 2 LA TO200 MTOdUCION a a a rs Edel 2 Past Product Feul scs i etc eink a ene 2 Operation GUS cnn adria distin 5 21 KEY MIAO HOP ar d a a ae eats a 5 2 2 Management Mode iii aiii 5 BR User REIS tao O 5
22. of sensor tapes recommended Note Any problems send the compressed Log file to us by e mail which is in the installation path 5 2 Interface Illustration 26 SST rT Port SV USB 5 3 Illustration for pressing fingerprint Correct method EBA Place the center of the finger on the center of scanner window Wrong method Too small valid area left of center right of center Defluxion Too down 1 It is better for each user to register two finger prints in case of one finger can not work 2 Place finger flatly and the center of the finger is on the center of scanner window and press a little hard on scanner so it can scan as large finger area as possible to extract enough minutia 3 Keep the angle and direction of finger the same each time placing on scanner 4 If your finger has sweat or water please make it dry first and then register 5 If your finger is too dry make it a little wet or touch the forehead to increase oily of the finger press a little hard on scanner the dry finger can cause the finger image not clear 6 Avoiding the callus peeling or injury of the finger to ensure the register and identification successful 7 You d better register the thumb first and then index finger or middle finger to increase the precision Al
23. t and the staff information will be saved successfully Note Staff number is the sole number for differentiating each staff which can not be in duplicate if the staff number already exists system will prompt that staff number already exists when clicking Save button Modify staff information First choose the right staff in the staff list that will be modified then directly modify information of Name Sex Tel and Photo etc and click Save button which will successfully save staff modification Please note Photos of staff can be selected or deleted by clicking View and Clear Delete Staff First choose one or multi staff that will be deleted from staff list click Del button under the staff list and a confirmation wndow will pop up as following 2 Are you sure to delete the selected staff OK ci cl Click OK to delete staff Please note lt will delete the time attendance records and records of asking for leave simultaneously with the deletion of staff Right click on the staff list and a short cut menu will pop up accordingly as following Depatman list Shaft let Shalt s Alsen Chit we a Audi 300 Civil HA a Hara F Gales Imunet Ohler Y Tec Femal Select sl Cia Canned Chr Tal TZA Import Import staff information from Excel files to software 16 Select all Select all staff in the staff list Cancel Cancel the selection of staff Transfer to Transfer the