DSE7310 & DSE7320
Contents
1. minute in each of 3 major axes 5Hz to 8Hz 7 5mm constant displacement 8Hz to 500Hz 2gn constant acceleration BS EN 60068 2 27 SHOCK 3 half sine shocks in each of 3 major axes 15gn amplitude 11mS duration BS EN 60529 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES IP65 Front of module when installed into the control panel with the supplied sealing gasket NEMA RATING APPROXIMATE e 12 Front of module when installed into the control panel with the supplied sealing gasket ELECTRONIC ENGINE CAPABILITY BENEFITS e 132 x 64 pixel ratio makes information easy to read Real time clock provides accurate event logging PC software is license free Set maintenance periods can be configured to maintain optimum engine performance Ethernet communications provides advanced remote monitoring at low cost Modules can be integrated into building management systems Preventative maintenance avoids expensive engine down time Advanced PCB layout ensures high reliability Robust design Extensive performance monitoring OPERATION The modules are operated via the START STOP AUTO and MANUAL soft touch membrane buttons on the front panel The DSE7320 also has a TEST button Both modules include load switch buttons The main menu system is accessed using the five navigation buttons to the left of the LCD display CONFIGURATION The modules can be configure
2. DSECONTROL MONITORING WITH INTELLIGENCE DSE7310 amp DSE7320 AUTO START amp AUTO MAINS FAILURE CONTROL MODULES COMMUNICATIONS amp EXPANSION DEEP SEA ELECTRONICS The DSE7310 and DSE7320 are new control modules for single gen set applications The modules have been developed from the successful DSE5310 and DSE5320 Series and incorporate a number of advanced features to meet the most demanding on site applications The DSE7310 is an Automatic Start Control Module and the DSE7320 is an Auto Mains Utility Failure Control Module Both modules have been designed to start and stop diesel and gas generating sets that include electronic and non electronic engines The DSE7320 includes the additional capability of being able to monitor a mains utility supply Both modules include USB RS232 and RS485 ports as well as dedicated DSENet terminals for expansion device connectivity The modules are simple to operate and feature a newly designed menu layout for improved clarity Enhanced features include a real time clock for enhanced event and performance monitoring ethernet communications for low cost monitoring mutual standby to reduce engine wear and tear trend analysis to assist in the detection of patterns in engine status and preventative maintenance designed to detect if engine parts have developed fault conditions so they can be replaced before a major problem occurs FEATURES e Backed up real ti
3. ERGENCY STOP LOW OIL PRESSURE HIGH COOLANT TEMP FUEL LEVEL SENDER 50 aw 55 o qt N xg a ies Eee ees gt gt z 44 1 2 FUEL CRANK BATTERY NEGATIVE MUST BE GROUNDED BATTERY TERMINALS SUITABLE FOR 22 16 AWG 0 6mm 1 3mm FIELD WIRING TIGHTENING TORQUE 0 8Nm 716 ELECTRICAL INTERLOCK 2 AMP 2 AMP FUSES FUSES PEET MODULE 7310 7320 GENERATOR LOADING RELAY OUTPUT D l R S T Ea DSE NET LOADING MAINS VOLTS HIGH SPEED RELAY 7320 PERIPHERAL LINK ALL MODELS MAINS PROGRAMMING PORT 4 FET OUTPUTS PLANT VE T T1 ENGINE ECU 8 INPUTS 1 1 USER CONFIGURABLE VE INPUT A USER CONFIGURABLE VE INPUT B USER CONFIGURABLE VE OUTPUT E USER CONFIGURABLE VE OUTPUT F USER CONFIGURABLE VE OUTPUT G USER CONFIGURABLE VE OUTPUT H USER CONFIGURABLE VE INPUT E USER CONFIGURABLE VE INPUT G USER CONFIGURABLE VE INPUT H USER CONFIGURABLE VE INPUT F mils JM USER CONFIGURABLE VE INPUT C NOTE 2 120 R TERMINATING RESISTOR MAY BE REQUIRED EXTERNALLY SEE ENGINE MANUFACTURERS LITERATURE USER CONFIGURABLE VE INPUT D NOTE 1 THESE GROUND CONNECTIONS MUST BE ON THE ENGINE BLOCK AND MUST BE TO THE SE
4. NDER BODIES THE GROUND WIRE TO TERMINAL 15 MUST NOT BE USED TO PROVIDE A GROUND CONNECTION TO ANY OTHER DEVICE DEEP SEA ELECTRONICS PLC TELEPHONE EMAIL Highfield House 44 0 1723 890099 sales deepseaplic com Hunmanby Industrial Estate Hunmanby North Yorkshire FACSIMILE WEBSITE YO14 OPH England 44 0 1723 893303 www deepseaplic com Registered in England amp Wales No 01319649 VAT No 316923457 DEEP SEA ELECTRONICS INC TELEPHONE EMAIL 3230 Williams Avenue 1 815 316 8706 sales deepseausa com Rockford IL 61101 2668 USA FACSIMILE WEBSITE 1 815 316 8708 www deepseausa com YOUR LOCAL DISTRIBUTOR CE Cg PENDING DEEP SEA ELECTRONICS PLC maintains a policy of continuous development and reserves the right to change the details shown on this data sheet without prior notice The contents are intended for guidance only APC MEMBER ASSOCLATION COMMECTING JCS INOWST AES ELECTAORMCS This data sheet is printed Qlives 55 Silk which is produced with 55 recycled fibre from both pre and post consumer sources together with 45 virgin ECF fibre 055 051 02 09 4
5. d using the front panel buttons or by using the PC software and a USB lead COMMUNICATIONS The DSE7310 amp DSE7320 have a number of different communication capabilities SMS Messaging When the module detects an alarm condition it has the ability to send an SMS message to a dedicated mobile number s notifying an engineer of the exact time date and reason why the engine failed GSM Modem and SIM Card required Remote Communications When the module detects an alarm state it dials out to a PC notifying the user of the condition Modem required Remote Control The module can be controlled remotely using either a GSM Modem Ethernet via DSE860 865 or via RS485 Using a modem allows the module to be controlled from any distance Using RS485 limits the distance to 1km 0 6 miles Building Management The module has been designed to be integrated into new and existing building management systems using RS485 PC Software The module has the ability to be configured and monitored from a remote PC using the PC software and a USB lead INPUTS amp OUTPUTS Analogue inputs are provided for oil pressure coolant temperature and fuel level These connect to conventional engine mounted resistive sender units to provide accurate monitoring and protection facilities They can also be configured to interface with digital switch type inputs for low oil pressure and high coolant temperature shutdowns Eight user configurable digital inputs a
6. k with DSENet compatible control modules DSENet allows up to 20 different expansion devices to be used at a time 10 of these devices can be of the same type excluding DSE2130 The expansion modules available are Available Now DSE2157 Relay Output Expansion Module DSE2130 Input Expansion Module DSE2548 Annunciator Module Remote Display Module Coming Soon FET Output Expansion Module NFPA 110 Interface Module Identification Dongle EVENT LOG The module includes a comprehensive event log that shows the most recent 250 alarm conditions and the date and time that they occurred This function assists the user when fault finding and maintaining a generating set ELECTRONIC ENGINE COMPATABILITY e CAT Cummins Deutz John Deere MTU Perkins Scania Volvo IVECO Generic Plus additional manufacturers DSE7310 amp DSE7320 FROM GENERATOR 1 12 L3 MECHANICAL INTERLOCK ET LOAD DSE7320 ONLY CT s 1 5 AMP SECONDARY PROTECTION CLASS L1 A i i L2 all 2 __ ry 1 l FROM MAINS ee UTILITY i T CT2 V W N Fi Li 12 1 GEN CURRENT GEN VOLTS RS485 RS232 Ute FLEXIBLE IF J1939 IN USE FLEXIBLE IF J1939 IN USE a d m SCR BATTERY SENDER COMMON FUEL FLEXIBLE FLEXIBLE SENDER EM
7. log 250 showing date and time Manual fuel pump control Alternative configuration Multiple date and time scheduler 3 Programmable Maintenance alarms with comms alert e Customisable status screens e Low fuel level alarm delay e Charge alternator fail warning and shutdown alarms with user programmable delay e Independent Earth fault trip Sleep mode e Load switching Load shedding and dummy load outputs Manual speed trim on CAN engines that support this feature Additional display screens to help with modem diagnostics Security levels PC software has password system to control access to PC software features Operator configurable virtual LEDs visible in SCADA DC SUPPLY CONTINUOUS VOLTAGE RATING 8V to 35V Continuous CRANKING DIP PROTECTION Able to survive OV for 50mS providing supply was at least 10V before dropout and supply recovers to 5V This is achieved without the need for internal batteries CHARGE FAIL EXCITATION OV to 35V fixed power source 2 5W MAXIMUM STANDBY CURRENT 160mA at 12V 80mA at 24V MAXIMUM OPERATING CURRENT 340mA at 12V 160mA at 24V ALTERNATOR INPUT RANGE 15V 333V L N 50Hz 60Hz Minimum 15V AC Ph N ACCURACY 1 of full scale true RMS sensing SUPPORTED TOPOLOGIES 3 phase 4 wire 3 phase 3 wire Single phase 2 wire 2 phase 3 wire L1 amp L2 2 phase 3 wire L1 amp L3 MAINS UTILITY INPUT DSE7320 ONLY RANGE 15V 333V L N 50Hz 60H
8. me clock 132 x 64 pixel LCD display Configurable display languages USB connectivity Robust module enclosure Five key menu navigation Durable soft touch membrane buttons Fully configurable via PC software LED and LCD alarm indication Engine exercise mode Configurable start amp fuel outputs kWh monitoring Automatic load transfer Eight configurable digital inputs Six configurable outputs Configurable timers and alarms Modbus RTU Magnetic pick up Front panel programming Multiple date and time exercise scheduler SMS messaging Power save mode PIN protected programming User selectable RS232 amp RS485 communications DSENet compatible e Ethernet communications via DSE860 865 e Customer logo display capability e Multiple date and time maintenance scheduler e Configurable display pages Programmable load shedding acceptance Trend analysis Preventative maintenance kW overload protection Unbalanced load protection PDA compatible PC software Flexible sender input Configurable SCADA output page Lae DEEP SEA ELECTRONICS NEW FEATURES e True dual mutual standby with load balancing timer e Fan control for additional cooling e Protections Disabled facility e Fuel usage monitoring and low fuel alarm e Support for up to three remote display units e Automatic sleep mode e Easy access configurable diagnostics page shows summary of output states Improved programmable event
9. re also included plus one flexible sender Relays are provided for fuel solenoid output start output and six additional configurable outputs On these configurable outputs a range of different functions conditions or alarms can be selected INSTRUMENTATION The modules provide advanced metering facilities displaying the information on the LCD display The information can be accessed using the five key menu navigation to the left of the display 7310 7320 Generator Instruments Volts Hz Amps kW kVA Pf kWh kVAr kVArh KVAh Generator Instruments Volts Hz Amps kW kVA Pf kWh kVAr kVArh KVAh Engine Instruments RPM Oil Pressure Coolant Temperature Hours Run Charging Voltage Battery Volts Engine Instruments RPM Oil Pressure Coolant Temperature Hours Run Charging Voltage Battery Volts Electronic Engines Enhanced Instrumentation and Engine ECU diagnostics via electronic engine interface Electronic Engines Enhanced instrumentation and Engine ECU diagnostics via electronic engine interface Mains Utility Instruments Volts Frequency Amps optional when CT s are fitted load side of the line RELATED MATERIALS TITLE PART NO S DSE7xxx Manual 057 074 DSE72xx 73xx PC Software Manual 057 077 DSE2130 Data Sheet 053 060 DSE2157 Data Sheet 053 061 DSE2548 Data Sheet 053 062 DSE860 865 Data Sheet 055 071 DSENET DSENet is a collection of expansion modules that have been created to wor
10. z Minimum 15V AC Ph N ACCURACY 1 of full scale true RMS sensing SUPPORTED TOPOLOGIES 3 phase 4 wire 3 phase 3 wire Single phase 2 wire 2 phase 3 wire L1 amp L2 2 phase 3 wire L1 amp L3 BURDEN 0 5VA PRIMARY RATING 1A 8000A user selectable SECONDARY RATING 1A or 5A secondary user selectable ACCURACY OF MEASUREMENT 1 of full load rating RECOMMENDATIONS Class 1 required for instrumentation Protection class required if using for protection Continued on page 2 MAGNETIC PICKUP VOLTAGE RANGE 0 5V minimum during cranking to 70V peak FREQUENCY RANGE 10 000 Hz max RELAY OUTPUTS OUTPUT A FUEL 15 Amp DC at supply voltage OUTPUT B START 15 Amp DC at supply voltage OUTPUTS C amp D 8 Amp 250V Volt free AUXILIARY OUTPUTS E F G H 2 Amp DC at supply voltage OVERALL 240mm 181 14mm x 41 7mm CAM SCH SAL PANEL CUT OUT 220mm x 160mm Gi XOS Max panel thickness 8mm 0 3 ELECTRICAL SAFETY ELECTROMAGNETIC COMPATIBILITY BS EN 60950 Safety of Information Technology Equipment including Electrical Business Equipment BS EN 61000 6 2 EMC Generic Immunity Standard Industrial BS EN 61000 6 4 EMC Generic Emission Standard Industrial ENVIRONMENTAL BS EN 60068 2 1 Cold Temperature 30 C BS EN 60068 2 2 Hot Temperature 70 C BS EN60068 2 30 HUMIDITY Test Db cyclic 93 RH 40 C for 48 hours BS EN 60068 2 6 VIBRATION 10 sweeps at 1 octave
Download Pdf Manuals
Related Search
Related Contents
製品をご使用になる前に必ずお読み下さい caution - Jacobsen Samsung UN39H5204AFXZA User's Manual JU 2015 - Université de Strasbourg erfolgsfaktoren mobiler kommunikation im aussendienst diplomarbeit TOUCHSCREEN REPEATER PANEL INSTALLATION MANUAL オーナーズマニュアル N8160-27 Upgrade型DLTライブラリ用増設筐体取扱説明書 吸光光度計 DR3900 Analox 1000 Series User Manual Copyright © All rights reserved.