Home
User Manual - CBM of America
Contents
1. cBMV Communications Technology Solutions Installation Manual CBM IP MPA Internet Protocol Multi Protocol Adapter Version 1 0 7 August 2008 CBM of America Inc 1455 W Newport Center Drive Deerfield Beach FL 33442 800 881 8202 INDEX PREFACE Page 3 Warranty Page 3 Copyright Page 3 Scope Page 3 Organization Page 3 NEBS Compliance Page 3 Support Page 3 Documentation PRODUCT OVERVIEW Page 4 Product Description Page 4 Physical Specifications and Features Page 4 Operational Specifications Page 5 Part Numbers INSTALLATION AND INITIAL CONFIGURATION Page 5 Unpacking and Handling Page 6 Installation of the IP MPA Page 8 Initial Configuration Page 9 Pin Assignments Page 10 Addendum A Optional Accessories amp Parts Preface Warranty CBM of America warrants that its equipment is free from defects in material and workmanship The warranty period is one year from the date of shipment CBM of America s obligation under this warranty is limited to the repair or replacement of the defective equipment provided it is returned to CBM shipping prepaid within a reasonable penod of tme This warranty shall not apply to equipment that has been subject toaccident misuse alterations or repairs not made or authorized by CBM Copyright This publication and the equipment it describes contain propriety information No part of this document may be copied
2. 4 3 x Height 1 1 1 7 with bracket Standard 19 inch relay rack mounting shelf can accommodate 5 IP MPA units the 23 inch relay rack model can house 6 units 1 75 inches high One Rack Unit IRU Mounting IP MPA without shelf in a vertical orientation directly on the rack upright occupies 3 5 inches of relay rack space Unit supports 48VDC and Power Over Ethernet POE 48VDC uses the Mate and Lock Phoenix power connector on the device Unit operates regardless of polarity on this connector Power adapter also available from CBM to convert from 110VAC to A8VDC Fully NEBS Level 3 Certified Operational Specifications O O O Operating Voltage AC to DC Power Supply 9mA Nominal 15mA Maximum DC Standalone 21mA Nominal 30mA Maximum Operating temperature 5 to 40 degrees C 41 to 124 F Operating humidity 5 to 90 non condensing Part Numbers Part Description Included w IP MPA Part Number Ordering IP MPA Unit CBMIP MPA IP MPA Adapter RJ45 DB25F CBMIP MPA ADP l2 Ft Green 10 AWG Ground Wire W Lug CBMIP MPA GND Ground Lug for IP MPA 10 AWG CBMIP MPA GLUG 10X32 Nut amp Star Washer for IP MPA Ground Lug CBMIP MPA NUT Terminal Block Plug Phoenix Connector CBMIP MPA TERMBLK Installation and Operation Unpacking and Handling Inspect the IP MPA carefully for any damage that may have occurred during shipment If any damage is observed contact CBM of America with the se
3. ARTS CBM Part No Adapter Sync 25 Pin DCE M For IPMPA To ADPG148 B SE ADPGI150 Adapter Sync 25 Pin DCE F RS232 To RS449 Converter DB25M to ADPG2116 DB37F 15FT RD BLK Twisted Wire w Terminal CBLG IPMPA DCPWR Block Plug CBLG2124 1 DB25M To DB25F Extender Cable CAT 5E 4PR 24awg PVC WECOS568B CBLG988 X Wiring Gray CBMIP MPA 5PK Mounting Shelf IRU 19 For 5 IP MPAs CBMIP MPA 6PK Mounting Shelf IRU 23 For 6 IP MPAs 9PADPACU F DB9 To RJ45 PC Adapter 10
4. available 24 hrs a day7 days a week via the CBM New Product Support Portal at www cbmusa com product support Enter your email name product catagory and problem severity level and your request for assistance will be routed to one of our support engineers for response If you would like a call back from one of our support engineers please make sure to enter your call back phone number Documentation In addition to this Installation Guide a copy of the IP MPA User Manual amp Software Release Notes can be accessed via www cbmusa com Click Tab On line Manuals Select CBM Products Product Overview Product Description The CBM IP MPA is a DC Powered NEBS Level 3 certified single port multiple protocol conversion mediation adapter The CBM IP MPA provides seamless inter networking of dissimilar network devices and allows for individual mediation of legacy connections to IP based networking infrastructure The CBM IP MPA s serial port is synchronous or asynchronous and supports speeds up to 115 2kbps Protocols such as asynchronous HDLC SDLC and X 25 are all supported and software selectable for the serial port Physical Specifications and Features O OOOHOO One 10 Base T RJ45 Ethernet Port with activity indicator One serial port female DB25 port supporting RS 232 V 11 RS 530 Serial port supports Asynchronous HDLC SDLC BX 25 and X 25 protocols Mediates IP TCP Telnet RTP ARP amp SNMP protocols Unit Width 3 1 x Depth
5. ed into the keyed socket on the front of the IP MPA Tighten the two retaining screws Polarity is anon issue as the IP MPA will accept negative feed and return in either combination Fuse accordingly as maximum draw is 30mA from a direct DC source such as a fuse panel Power Lead Pressure i Screws Retaining Screws pom A 4 aang i a Power Lead Sockets o The unit will operate utilizing POE through the LAN port connection o Both 48VDC and POE can be connected and powered at the same time if the customer wishes to provide diverse power feeds to device o The connection can then be made from the Local Area Network to the LAN port on the rear of the IP MPA Initial Configuration In most cases CBM will stage the IP MPA with an IP address specified by the customer This allows for a plug and play scenario Customer will have the ability to telnet to the unit to provision If this is not the case basic local configuration will be needed to make the unit available to the TCP IP network A local configuration kit will be necessary to connect a local PC to the IP MPA for this step The kit can be ordered or you can build one following the diagram on page 9 under Pin Configurations o Utilize IPMPA ADPTR PC KIT for connection of PC DB9 serial port to DB25 serial port on the IP MPA IP MPA should be powered down at this point o Open Hyperterm or application of choice on PC to allow for serial port communication o Se
6. or reproduced in any form without permission from CBM of Ameria The information in this document is subject to change without notice CBM of America assumes no responsibility for damages resulting from the use of this document included and not limited to lost revenue lost data or other damages Scope This manual describes how to install and initially configure the CBM IP MPA This document is intended for use by trained technicians and installers and assumes a working knowledge of central office procedures and protocols Organization The information contained in this document is arranged in two parts o Product Overview provides a physical description of the IP MPA and associated features o Installation and Operation details the necessary procedures required to install and initially configure the IP MPA NEBS Compliance This Class 2 data communications equipment has been Level 3 NEBS compliance tested and approved under the guidelines specified by the Bellcore GR 63 CORE and Bellcore GR 1089 CORE Technical References The CBMIP MPA conforms to the UL Standad for Safety ANSI UL 1950 Third Edition Support CBM of America maintains a support organization for the installation and operational of this product Call 800 881 8202 to request support between the hours of 8AM amp SPM EDT Monday through Friday Select option 4 for technical support Please have the serial number of the product available Web based support is also
7. rial number and the packing list from the unit Save the shipping container to return any damaged units Connector E ee cP eae ae e 48VDC act LAN Mate and Lock eh ae oye oat i ee a 10 Base T Ethernet Port Phoenix Power fe 2 5 Pr ee eat ae ae l n has lies Th i paced F h ie p estar gh i 4 E 1 T 1 i hess 3 PWR SESTI Front View Serial Port Female DB25 Grounding Lug RS 232 V 11 RS 530 P PESER a Rear View Installation of the IP MPA The IP MPA can be mounted in a standard 19 inch or 23 inch relay rack with or without mounting shelf To install o Mount IP MPA to relay rack This is accomplished by directly mounting to upright of relay rack If mounting shelf is to be used secure shelf first to the rack then mount any IP MPA s on the shelf If multiple IP MPA will be mounted consider attaching ground lead to IP MPA s prior to securing to shelf o Secure Ground Lead to IP MPA with provided nuts and star washers and ground lug after attaching to 10 AWG ground cable o Connect other end of Ground Lead to prepared surface on Relay Rack This will require the attachment of needed ground lug to the other end of the Ground Lead The Relay Rack lug and 10 AWG Ground Lead are included with the IP MPA o With power removed connect power cables to the connector provided see pictures below Tighten the two pressure screws to secure the power leads The connector then can be insert
8. t application to 9600 baud 8 Bits 1 Stop None for parity for the PC serial port o Make the connection from the PC application to the PC serial port then power on the IP MPA o During the boot sequence you receive the following warning Warning serial console will be disabled after 5 seconds Press Cntrl C to maintain use of the serial console You will then receive the console prompt below Enter the following text lt IP MPA gt lt IP MPA gt login passwd initial a lt IP MPA gt remove mod lt IP MPA gt local ipaddr 192 168 1 100 submask 255 255 255 0 lt IP MPA gt gateway ipaddr 192 168 1 1 lt IP MPA gt restore mod Please note that the address information above is provided for example purposes only The actual IP address subnet mask and gateway will need to be obtained from the customer directly and be unique to each IP MPA o After this process is complete and unit is connected to network backbone customer should try a simple ping to the IP MPA to ensure its availability to the network o After a successful ping a telnet to the unit utilizing port 1023 should be attempted Customer on remote machine would enter telnet xxx xxx xxx xxx 1023 x s denote actual IP address of IP MPA prompt lt IP MPA gt should appear Pin Configurations DCE DBS Console Cable PC IPMPA DBS Female DB25 Male For Console Connection to PC Laptop ADDENDUM A OPTIONAL IP MPA ACCESSORIES amp P