ADHESIVE MINI SCALE MANUAL

image

Contents

1. AMAGED BY ACCIDENT EXCEPT FOR THE EXPRESS WARRANTY CONTAINED IN THIS SECTION HENKEL MAKES NO WARRANTY OF ANY KIND WHATSOEVER EXPRESS OR IMPLIED WITH RESPECT TO THE PRODUCTS ALL WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND OTHER WARRANTIES OF WHATEVER KIND INCLUDING AGAINST PATENT OR TRADEMARK INFRINGEMENT ARE HEREBY DISCLAIMED BY HENKEL AND WAIVED BY THE PURCHASER THIS SECTION SETS FORTH EXCLUSIVELY ALL OF LIABILITY FOR HENKEL TO THE PURCHASER IN CONTRACT IN TORT OR OTHERWISE IN THE EVENT OF DEFECTIVE PRODUCTS WITHOUT LIMITATION OF THE FOREGOING TO THE FULLEST EXTENT POSSIBLE UNDER APPLICABLE LAWS HENKEL EXPRESSLY DISCLAIMS ANY LIABILITY WHATSOEVER FOR ANY DAMAGES INCURRED DIRECTLY OR INDIRECTLY IN CONNECTION WITH THE SALE OR USE OF OR OTHERWISE IN CONNECTION WITH THE PRODUCTS INCLUDING WITHOUT LIMITATION LOSS OF PROFITS AND SPECIAL INDIRECT OR CONSEQUENTIAL DAMAGES WHETHER CAUSED BY NEGLIGENCE FROM HENKEL OR OTHERWISE
2. LOCTITE MICRO DISPENSE SCALE Item 1174337 PLEASE READ COMPLETE INSTRUCTIONS BEFORE USE Please read all operating instructions carefully You can contact us at www loctite com Avoid lengthy exposure to extreme heat or cold The scale works best when operated at room temperature If the scale has been subjected to temperature change please allow the scale to acclimate to normal room temperature for at least one hour before use Allow sufficient warm up time Turn the scale On and wait several seconds to give the internal components a chance to stabilize before weighing The cleaner the environment the better Dust dirt moisture vibration air currents and proximity to other electronic equipment can all cause an adverse effect on the reliability and accuracy of your scale Handle with care Do not dispense directly onto scale Gently apply items to be weighed to a sacrificial tray tin foil or a small cup Although the scale is designed to be quite durable try to avoid rough treatment as this may permanently damage the internal sensor and void your warranty Avoid shaking dropping or otherwise shocking the scale This is a precision instrument and MUST BE HANDLED WITH EXTREME CARE Important Advice Place the item to be weighed on the platform close scale cover after the stable weigh is displayed remove the item immediately This will prolong the longevity and accuracy of this weighing instrument The
3. e and accurate weighing However an abused scale will only work until its sensors are damaged KEY PAD FUNCTIONS UNIT For unit mode selection press and release the key once to change weight unit You can select g grams oz ounces dwt pennyweight ozt troy ounces ct carats gn grain or mg PCS Count Sample sizes can be 10 20 50 or 100 The following steps outline the procedure for cumulative weighing of samples Switch the scale On Place a given number of samples of an item on the tray Press the UNIT key several times to put the scale in PCS mode noted by PCS indicator on display Select the sample size the same as you chose above by pressing the PCS key as many times as necessary to put in the correct sample size Press the UNIT key the display will show pass then after 2 seconds the scale will remember the sample size you selected and show the starting sample size on the display you can now remove the samples if you want to return to 0 pcs Place the items that you want counted onto the tray the total number of items will show on the display Press the UNIT key to exit the counting function and return to normal weighing OON OFF Press this key to turn unit on Once the unit is on press and hold the same key to turn the scale off ZERO tare Press Zero to reset the scale to zero This can be used for eliminating from a sample or a tray container the weight value of a container wei
4. ed weight you can purchase one at a local store In emergency situations you can use coins ie 2 US Nickels 10 grams as a calibration weight 1 Place the scale on a Flat very stable surface and turn it OFF 2 Press and hold UNIT first the Press ON OFF don t release the unit button until the display shows the random AD value 3 Wait 2 seconds Press UNIT The display will show OSAVE after 2 seconds the display will show the calibration weight amount 4 Place the correct calibration weight on the platform then press UNIT the display will show OSAVE and return to AD value 5 Calibration is complete Remove the weight and turn the scale OFF Note If after calibration your scale does not read accurately this indicates calibration error and the calibration process should be repeated slower Please calibrate on a very stable surface INACCURACY ERROR The primary reasons for inaccuracy or malfunction are low batteries incorrect calibration overload or operating on an unstable surface Please keep this in mind and maintain and operate your scale properly The scale is a precise instrument and must be handled with the utmost care and caution FEATURE Power Up Segment Test When first turning the unit on all segments of the display will appear The display will remain for approximately 2 seconds and then reset to 0 Overload When an applied load exceeds the capacity EEEE will ap
5. ght is permanently removed for the remainder of the procedure Just turn the scale On place the tray or container on the weighing platform and press the Zero key The scale will show 0 0 or 0 000 on the display and you can add items to the container tray NOTE When all weight is removed from the weighing tray the tarred value of a container will be displayed as a negative number Cycle the power on the scale to reset the scale LIGHT Press the LIGHT key to turn on the backlight press the LIGHT key again and the backlight will turn off These electronic scales are precision instruments Avoid disturbing environmental conditions such as currents vibrations strong electrical and magnetic fields as well as rapid change of the ambient temperature Selection of auto shut off mode Press and hold ZERO then press ON OFF The scale will enter the function settings mode The display will show A ON or A_OFF Press ZERO the display will show A_ON this means auto shut off function is active Press ZERO again the display will show A_OFF this means that the auto shut off function is inactive Manual P N 8901688 Rev B 04 2009 WARRANTY Henkel expressly warrants that all products referred to in the Instruction Manual for 1174337 Henkel Micro Dispense Scale hereafter called Products shall be free from defects in materials and workmanship Liability for Henkel shall be limited as its option to replacing tho
6. pear on the display Remove the excessive load immediately Although the scale uses proprietary overload protection technology it is still possible to damage the weighing sensor by overload Remember You can permanently damage the scale by overloading it TROUBLESHOOTING amp OPERATION NOTES 1 If the display ever becomes locked on EEEE this indicates that the scale was shocked dropped or otherwise damaged and the delicate weighing sensors have been damaged You can try recalibrating the scale if the sensor has not been hurt too badly it will work again after calibration Otherwise you will have to follow the warranty instructions that came with your scale 2 If the display shows Lo b this often indicates low batteries If new batteries do not fix this error the scale will have to be sent to us for replacement under our 1 year warranty program Although the scale is designed to be extremely durable it s important that you never overload or drop shock the scale Scales are delicate instruments and unlike cellular phones scales have delicate sensors that determine how much an item weighs If you drop or shock your scale these sensors feel the shock and are sometimes destroyed this happens with all digital scales Our scales are designed to be resistant to shock or drops as much as possible however this no way to protect 100 against load cell or sensor damage A well treated scale will provide years of reliabl
7. se Products which are shown to be defective in either materials or workmanship or to credit the purchaser the amount of the purchase price thereof plus freight and insurance charges paid therefor by the user The purchaser s sole and exclusive remedy for breach of warranty shall be such replacement or credit A claim of defect in materials or workmanship in any Products shall be allowed only when it is submitted in writing within one month after discovery of the defect or after the time the defect should reasonably have been discovered and in any event within 12 months after the delivery of the Products to the purchaser This warranty does not apply to perishable items such as batteries tray cover lights etc No such claim shall be allowed in respect of products which have been neglected or improperly stored transported handled installed connected operated used or maintained In the event of unauthorized modification of the Products including where products parts or attachments for use in connection with the Products are available from Henkel the use of products parts or attachments which are not manufactured by Henkel no claim shall be allowed No Products shall be returned to Henkel for any reason without prior written approval from Henkel Products shall be returned freight prepaid in accordance with instructions from Henkel NO WARRANTY IS EXTENDED TO ANY EQUIPMENT WHICH HAS BEEN ALTERED MISUSED NEGLECTED OR D
8. se electronic scales are precision instruments Do not operate near an in use cell phone cordless phone radio computer or other electronic device These devices emit RF and can cause unstable scale readings If your scale ever performs poorly try moving the scale to a different room or location This is a very precise scale the display may seem to wander or jump when weighing This is due to air currents or vibration Stable weighing is achieved when the display remains fixed for 3 seconds OPERATION Battery Operation 1 Three AAA size ALKALINE batteries are required 2 To install the batteries a Release the battery cover by sliding outwards b Place batteries into battery compartment aligned correctly C Replace battery cover DO NOT USE EXCESSIVE FORCE amp DO NOT PRESS ON THE TRAY 3 The scale is now ready for battery operation Advanced users only CALIBRATION IMPORTANT This scale was professionally factory calibrated before shipment and does NOT need to be calibrated by the end user However if you wish to recalibrate your scale we provide these instructions for correct calibration Incorrect calibration can occur if you do not follow the steps exactly If your scale does not perform accurately please try replacing the batteries before you calibrate You will need a 20 gram weight to calibrate this scale included Note if you have lost the calibrated weight and you do not have access to a calibrat