Introduction PWS6300S Operating Guide HITECH
Contents
1. time to download an application to the HME otherwise select Application Download Application The following should appear on the screen while the PWS6300S is downloading Programming AP Uploading an Application An application can also be uploaded from the HMI to the PC Thus a user can save an application as a V6F file in ADP for future use Warning To avoid an electronic shock be sure to switch off the power before connecting the communication cable to the HMI Make sure that the HMI and the PC are connected shown as in Section J Set the dip switch SW7 ON After a self test the System Menu will be displayed on the screen and the PWS6300S is ready to upload an application Also make sure that communication parameters are correctly configured Select File Upload Application in ADP and the Save As dialogue box will appear on the screen Enter the name of a firmware file AF6 to save Click Save Then the HMI will prompt a user to ask for a password enter the password set in ADP from Application Workstation Setup Once a password is entered the PWS6300S starts to upload an application to the PC For setting a password 6 please refer to Section JJ While the PWS6300S is uploading its screen should appear as the following Uploading FW After uploading select File Reconstruct Source in ADPand the Open dia logue box wi
2. PWS630U Operating Guide M Introduction PWS6300S is a Human Machine Interface HMI witha 3 STN LCD of a high resolution 160 80 and is IP65 NEMA4 proof with water and dust resistant The PWS6300S is CE marked and meets your need to be highly transientresistant while it is in operation Also its compact design makes connections with other machinery more flexible thus achieving the optimal performance of yourmachines The latest released ADP Version 6 0 and above is used to design applications of the PWS6300S it is reliable user friendly and compatible with many models PERITECH F7 F8 6 F9 7 8 9 F4 F5 F6 4 5 6 F1 F2 F3 1 2 f3 7 T F10 ae Bs fesc At ean coe RA Self test Once the PWS6300S is turned on it will automatically execute a self test to check its hardware The result of a self test is displayed on the LCD See below The items to check in a self test BIOS Version V1 0 C 2004 HITECH CORP System RAM 128KB Flash Memory 4MB Battery check 2 or xX Parameter check or x BI 2 or X Firmware check or x Application check or x RTC check or x DIP SW 8 1 11011111 or other combinations Figure 1 PWS6300S Power on Self test If any of the above items does not pass a self test the following message will be displayed on the screen for
3. a designer to create a button which displays a Password Table on the HMI so a user with the right of access to the table can register passwords and user s levels in the table Figure 6is an example to display a Password Table on the HMI in this example TBL button is an action button which displays a Password Table Select this button and then a Password Table will be displayed on the screen for the user with the right to access the table Use to move and to highlight an area for entering a value See Figure 7 For the details on the Action Button please refer to ADP User s Manual 6 we 166 Figure 6 An example of setting a password Password Lv1 00000000 00000000 00000000 1 1 Fi 1 00000000 1 1 1 1 CANCEL 00000000 00000000 00000000 00000000 1 Figure 7 Password Table F2 OK ONOoOahaOND After registering passwords and user s levels set the dip switch SW6 ON i e password required Restart the HMI and after a self test a user will be asked to input a password to run the HMI See Figure 8 Password Figure 8 Password required to run the HMI The HMI will determine auser s level from a password entered by a user For instance if the level of a password entered by a user is 1 then the HMI will set the user s level 1 if the level of a password entered by a user is 2 then the HMI will set the user s level 2 The user s lev
4. about two seconds and then disappeared Error code 0x18 Wait for a minute to continue If power to the HMI or the PC was interrupted while downloading the item Firm ware check or Application check will not pass a self test and will be checked with an x mark after power is restored The situation is normal and users can simply follow the download procedures to re download an application or data After downloading all items should pass the next self test 2 System Menu Set the dip switch SW7 ON After a self test the System Menu of the PWS6300S should be displayed on the screen Wait commana Link Copy Run Figure 2s PWS6300S System Menu Note that when a command is highlighted on the screen with a black background this indicates that the command is currently being executed by the PWS6300S Command with gray background e g F7 F8 could be executed if the associated function keys are pressed The functions of the commands are briefly explained in the following table PWS 6300S System Menu Function Link The HMI is connected F7 Confg parameters in the HMI Use and to move to desired field and and to set the value of the field F8 Copy Copy application data to another PWS6300S Set up the internal time clock and communication F9 Run Run an application a Ey Keypad There are 16 keys in the PWS6300S and they can be categorize
5. d into Numerical Keys Navigation Keys and Functional Keys See below The F1 F10 keys are the Functional or Auxiliary Keys which could be defined in ADP The functions of these keys could be for example setting a PLC bit or register changing a screen or displaying a password table etc Please refer to ADP User s Manual for details F1 F10 Keys ENTECH Numerical Key F7 A F8 E F9 a 7 8 9 ae F4 F5 Z F6 2 4 5 6 F1 F2 F3 1 2 73 o z P t F10 DKEA Aee Navigation Key When a key is pressed the HMI will make a beep sound to signal that a command is pressed The default is 200 mill seconds and is configurable EN Bench and Function Tests If the dip switches SW3 and SW4 OFF then one is able to run the Bench and Function Tests for the PWS6300S Turn on the HMI and then the following screen will be displayed Bench Function Test Test Figure 3 PWS6300S Test The test items are listed in the following table PWS6300S Tests Items Keyboard Test 16 keys BIOS System RAM Flash memory Buzzer LED F9 B h T 9 enc est BIOS Battery Status RTC COM port Flash ROM Fl LED F5 RS232 i F2 Buzzer F6 RS422 eS 3 DIP SW F7 RS485 F4 LCD F8 KEY 5 Setting Parameters There are two options to configure working parameters a user can set parame
6. el 1 has the highest privilege and the user s level 9 has the lowest Also note that only a user with the user s level 1 has the right of access to the Password Table Scenario 2 Re enter a password The Object Action Button in ADP is also available for a designer to create a button which asks a user to re enter a password For example select button in Figure 9 and then the HMI will prompta user to re enter a password The HMI will update a user s level according to the most recent password which has been entered Therefore this button can be applied to raise or drop one s privilege while the HMI is in operation For the details on the Action Button please refer to ADP User s Manual Figure 9 The HMI asks for a password Scenario 3 A password is asked to execute a button on the HMI A designer can design a button which requires a password to execute it For example a Goto Screen button can be designed with a high level of security that is it will require a password with a high level of privilege As the button is selected and the current user has a lower privilege than the button which has been set for the HMI will prompt a user to ask for a password also see Figure 9 A user will need a password with at least the level of privilege which the button has been set for This function can restrict a user to access to certain parts of an application Scenario 4 Enter a password to copy or upload an applicati
7. ll appear on the screen Open an uploaded application file C64 or AA6 and then an application screen will show up in the PC Finally select File Save As to save an application as a V6F file Thus a source file can serve the purposes of maintenance and modification 8 Copying In the System Menu select F8 Copy to copy an application from the PWS6300S to the other PWS6300S Set the dip switch SW7 ON and connect two PWS6300S with a download cable in COM2 After a self test the System Menu will be displayed on the screen Select F8 Copy in the System Menu fromthe PWS6300S with the application to be copied The HMI will prompt a user to ask for a password enter the password set in ADP from Application Workstation Setup Once a password is entered the PWS6300S starts to copy an application to the other PWS6300S For setting a password please refer to Section JB The followings should appear on the screens while the PWS6300S is copying an application to the other Copying FW Programming FW IT F IT F Copy Link Figure 7 Copying to the other Figure 5 Copying from the other PWS6300S PWS6300S 9 Setting a Password 4 Scenarios ET Scenario 1 A password is required to start the HMI If the dip switch SW6 is ON then a user needs to enter a password to start the HMI For this purpose the Object Action Button in ADP is available for
8. on Once F8 Copy in the System Menu or File Upload Application in ADPis selected the HMI will also prompt a user to ask for a password A user will need to enter the correct password to copy an application from one HMI to another Note that this password is different from those passwords set in Scenario 1 3 To set this password select Application Workstation Setup in ADP On the Password tab a designer is then able to set the password HITECH ELECTRONICS CORP Web Site http www hitechsite com Head Office 4 FI No 501 15 Chung Cheng Rd Shin Tien Taipei Shien Taiwan R O C Tel 886 2 22183600 Fax 886 2 22183060 Marketing Division 4 FI No 501 15 Chung Cheng Rd Shin Tien Taipei Shien Taiwan R O C Tel 886 2 22180660 Fax 886 2 22189547 Copyright 2004 Hitech Electronics Corp All rights reserved Specification subject to change without notice
9. ters in the HMI or ADP To set parameters in the HMI select F7 Confg in the System Menu Remember to set the dip switch SW5 ON if parameters are set in the HMI A user can also choose to set parameters in ADP To set parameters in ADP select Application Workstation Setup On the Connection tab a user is then able to set communication parameters Remember to set the dip switch SW5 OFF if parameters are set in ADP 6 Downloading an Application First make sure that the HMI and the PC are connected The way to connect the HMI and the PC is illustrated below PWS COM2 PC COM RS232 9 pin male 9 pin female RXD 2 3 SD TXD 3 2RD GND 5 585G RIS 7 ae 8CTS ersg io t 7RTS iat 6 DSR posse 1 CD i 4A DTR PWS _ _ PC Warning To avoid an electronic shock be sure to switch off the power before connecting thd download cable to the HMI Set the dip switch SW7 ON After a self test the System Menu will be displayed on the screen and the PWS6300S is ready to download an application Open an application file to be downloaded in ADP and make sure that communica tion parameters are correctly configured Also remember to compile a file before downloading if not yet Please note that one needs to compile a file before downloading or anytime a change has been made in a file Next select Application Download Firmware and Application in ADP if it is a first
Download Pdf Manuals
Related Search
Related Contents
buoyancy aid / life jackets / floatation garments sortiment British Telecom Diverse 6350 2 - B&B Electronics Manuale dell`utente Commercial Kitchen Exhaust Hoods IMPRESSA E10/20/25 Bedienungsanleitung User Manual T50 Second Edition OEM user manual Samsung Galaxy Y Pro Duos دليل المستخدم Copyright © All rights reserved.