Home

User`s Guide

image

Contents

1. User s Guide Microsoft Systems Center Operations Manager 2007 n Management Pack for InfraStruXure Central SFSCOM2007 Contents Introduction vwtbae isos sete a totes ow ee tas Integration Concepts 2 0 66 sisi wisi eae ene ieee ee eee eee dees Inventory Integration Service Model 0000eeeeeeee 1 Monitoring Integration Health Model 00ceueeeee 2 Console Integration 0 0 c eee eee eee 4 Initial SQwp irse a hey eee eae wawaw we awe ede Installation naian Gisele Deak ree ide bale od Gale eaie eae ee 5 Changing the Default Management Pack Behavior Using an Overrides Management Pack 000eee eee eee eees 6 Registering InfraStruXure Central Servers on Proxy Health Services 00 cece e eee eee eee eee 7 Registry Use in Alarm Collection 0000ee ee eeeee 8 Creating Run As Accounts and Assigning Them to the R n AS Profile ns 2 hc eae eee eee eee 9 Partitioning Large InfraStruXure Central Servers across Multiple Health Services 00 0c cece eee eee eee 9 Setting the Environment Variable ISXCUI 10 Topics Related to Operations 000 e eee eee 10 Inventory Discovery 2 c eee eee eee eee eee 10 Inventory Discovery Segments and Access to the TEMP Folder 2 2 2 e eee eee eee eee 10 Warning Events on Initial Inventory Discovery 11 International Characters in Inventoried Properties 11 Dr
2. OPERATING_MODE com apcc ISXC ISXCSensor State OUTPUT_CURRENT com apcc ISXC IS XCSensor Current OUTPUT_CURRENT_TOTAL com apcc ISXC IS XCSensor Current OUTPUT_LOAD_VA com apcc ISXC ISXCSensor ApparentPower OUTPUT_LOAD_WATTS OUTPUT_POWER_TOTAL_VA com apcec ISXC ISXCSensor Load com apcc ISXC ISXCSensor ApparentPower OUTPUT_POWER_TOTAL_WATTS OUTPUT_VOLTAGE com apcc ISXC IS XCSensor Power com apcc ISXC ISXCSensor Voltage Q1_INPUT_BREAKER Q2_OUTPUT_BREAKER com apcc ISXC ISXCSensor State com apcc ISXC ISXCSensor State Q3_BYPASS_BREAKER com apcc ISXC ISXCSensor State 16 Operations Manager 2007 Management Pack for InfraStruXure Ceniral RACK_INLET_TEMPERATURE com apcc ISXC ISXCSensor Temperature REAR_DOOR_HANDLE_STATUS com apcc ISXC ISXCSensor State REAR_DOOR_LOCK_STATUS com apcc ISXC ISXCSensor State REAR_DOOR_STATUS com apcc ISXC ISXCSensor State RUN_TIME_REMAINING com apcc ISXC ISXCSensor Time SENSOR_STATE com apcc ISXC ISXCSensor State SUPPLEMENTAL_DEVICE_STATUS com apcc ISXC ISXCSensor State SYSTEM_OUTPUT_CURRENT SYSTEM_OUTPUT_POWER_TOTAL com apcc ISXC IS XCSensor Current com apcec ISXC ISXCSensor Power SYSTEM_OUTPUT_POWER_USAGE_TOTAL TIME_ON_BATTERY com apcc ISXC ISXCSensor Power com apcc ISXC ISXCSensor Time UPPER_INLET_TEMPERATURE UTILITY_FAILURE_STATE com apcc ISXC ISXCSensor Temperature c
3. Windows Server i e the Microsoft Windows Server Computer Operations Manager class and looks for the registry keys that are written by the registration utility This rule is disabled by default which renders the Management Pack dormant on import Itis recommended that you create a group containing the computers running Windows Server in the overrides Management Pack and enable the rule for that group The various data collection rules These rules collect data points from various sensor types discovered and insert them into the operational database and data warehouse Because they can generate large amounts of data depending on the environment they are disabled by default It is recommended that you create a group containing sensors in the overrides Management Pack and enable the desired rules for that group See Optimizations to Reduce Impact and the Effect of Overrides on page 13 for an important discussion regarding the ramifications of certain overrides for these rules The alarm to alert mapping rules These rules collect all alarms that are raised on an InfraStruXure Central server and map them to alerts in the Operations Manager console Because these rules can generate a high volume of alerts depending on the environment and because these alerts must be closed manually the rules are disabled by default There are two rules one for devices and one for sensors Two other rules that mirror these rules collect the alarms and
4. State Check the Device State Filter for Warning State Set the State Check the Device State Filter for Critical State Set the State Since Operations Manager realizes that the Check the Device State component module of the workflows are all the same it will run this only once This is what is known as cooking down the script The output from that one invocation of the script will be fed to each filter condition detection and only the one that matches the specified criteria will continue the workflow and set the state accordingly This is the basic theory of operation of any monitor If the Check the Device State script requires the InfraStruXure Central Device Element ID as a parameter the extent to which Operations Manager can cook down the script ends there Although each device has three workflows that use the same invocation of the script Operations Manager will still be required to run the script once for each device This is the common design pattern of a scripted monitor that the script runs against a specific instance of the target and therefore must be run once for each target Operations Manager 2007 Management Pack for InfraStruXure Ceniral 13 14 In this Management Pack the aforementioned scripts do not require the target ID to be passed They only require the endpoint of the InfraStruXure Central server They all contact the InfraStruXure Central server and return a data set that represents all t
5. a single target Take care in specifying overrides in this Management Pack Warning Four of the rules provided in this Management Pack collect the alarms from the InfraStruXure Central server for devices two rules and sensors two rules and create Operations Manager events based on the content of the alarms as well as optionally generate alerts for these events These four rules actually share a common data source that assembles a data set of all alarms that have occurred on a given InfraStruXure Central server since the last collection These four rules must only be overridden together for all devices sensors on a given InfraStruXure Central server and using the same exact values If multiple configuration sets are created by overrides that do not follow these criteria the last collection time will be set in the registry of the Health Service computer by the first such configuration set to run The remaining configuration sets will run but will incorrectly determine the date at which they last ran These rules are designed to be overridden only under the conditions listed above In summary for all of the workflows referenced in the beginning of this section the cook down design pattern must be taken into account when specifying overrides for the values that affect the data source script TimeoutSeconds IntervalSeconds and SyncTime Script Events Generated by the Management Pack Events 2720 and 2721 are logged when the registration
6. acting as proxy before you create Run As accounts and assign them to the Run As profile defined in the Management Pack The first discovery run on a Health Service will run almost immediately after the Run As account is set If the InfraStruXure Central servers are already registered i e present in the registry the initial discovery will discover them Otherwise the initial discovery will not discover any registered InfraStruXure Central servers until the next run 15 minutes later Note When using a Health Service with an InfraStruXure Central server you must enable the Agent Proxy option under Agent Properties gt Security on the Health Service Operations Manager 2007 Management Pack for InfraStruXure Ceniral To use the registration utility start it from the Health Service that will be acting as the proxy A grid will be displayed that shows the InfraStruXure Central servers currently registered on that Health Service To add a new InfraStruXure Central registration click Add You will be asked to provide a name and fully qualified domain name FQDN for the InfraStruXure Central server The name can be any descriptive name The fully qualified domain name should be the IP address or FQDN of the InfraStruXure Central server Do not use a URL here The registry is updated immediately e InfraStruXure Central registrations on a Health Service must contain unique FQDNs as this is a key field in Operations Manager We also recom
7. sensor Dynamically created device groups that are derived from the system group type Note Device groups can be used for overrides but cannot be edited through the user interface Operations Manager 2007 Management Pack for InfraStruXure Ceniral e For the management group A group that contains all InfraStruXure Central servers registered on all Health Services A distributed application root object that represents the hierarchy by device groups the root object which contains component groups for each InfraStruXure Central server Each component group contains device groups discovered for that InfraStruXure Central server A distributed application root object that represents the hierarchy by device types the root object which contains component groups for all InfraStruXure Central servers registered on all Health Services which contain component groups representing each distinct device type for which at least one device was discovered for that InfraStruXure Central server which contain the devices discovered for that InfraStruXure Central servers that are of that particular type The dynamic distributed applications cannot be edited using the Distributed Application Designer The sensor types discovered by the Management Pack represent a subset of sensor types that may be found on an InfraStruXure Central server See Appendix 1 Included Sensor Types on page 16 for a complete list of the included
8. sensor types For any workflow that targets sensors instead of devices only sensor types that are included in the Management Pack will be monitored by the sensor rule Sensor types not included in the Management Pack will be covered by the device rule For instance there are two rules for the overall alarm health state of an entity device or sensor For sensor types that are discovered their overall alarm health state will be monitored by the unit monitor that targets the sensors For sensor types that are not discovered their overall alarm health state will be reflected in the unit monitor that targets the device that hosts that sensor This applies to any monitor or rule that monitors a trait of a sensor that is also reflected in the device alarm state overall state etc Some sensor traits e g data points are not reflected in the device and thus are not available for sensor types not included in the Management Pack Monitoring Integration Health Model The Management Pack defines several integration points of the health model of an InfraStruXure Central server In general all monitors and rules are configured to run every 5 minutes e For Devices Each device is monitored for its overall device state This is an attribute of the device itself whose value is mapped to one of the three Operations Manager health states Healthy Warning and Critical 2 Operations Manager 2007 Management Pack for InfraStruXure Central
9. Each device is monitored for its overall alarm health state This is an indicator of the overall state of the active alarms for a device This monitor will generally follow the health state of the most recent most severe active alarm for a device This is an overall health monitor however and does not map every alarm to a monitor state transition See the Product Knowledge article defined for the monitor in the Management Pack for more details Each device is also targeted by a pair of rules that collect alarms that have been generated since the last collection and perform these actions e Insert them into the Operations Manager operational database and data warehouse for display in event views and reports e Optionally generate an alert for each alarm This rule is disabled by default e For Sensors Each sensor is monitored for its overall sensor state This is an attribute of the sensor itself whose value is mapped to one of the three Operations Manager health states Healthy Warning and Critical Each sensor is monitored for its overall alarm health state This is an indicator of the overall state of the active alarms for a sensor This monitor will generally follow the health state of the most recent most severe active alarm for a sensor This is an overall health monitor however and does not map every alarm to a monitor state transition See the Product Knowledge article defined for the monitor in the Management Pack for
10. InfraStruXure Central server s registration is discovered It discovers all the device groups device group membership relationships devices and sensors visible to the discovery visibility is determined by the rights granted to the InfraStruXure Central server login represented by the Run As account assigned to the Run As Profile for this Health Service Inventory Discovery Segments and Access to the TEMP Folder 10 The maximum size of a single discovery data item in Operations Manager is 4 MB This is a security measure built into Operations Manager The discovery data item is an XML document and as such has the overhead associated with the text associated with starting and ending tags etc The result is that with larger InfraStruXure Central server inventories a single discovery data item cannot represent the entire inventory To overcome this the discovery is divided into segments There are 21 segments that are defined with the base Management Pack which will accommodate even the largest InfraStruXure Central server The operation of these segments is essentially identical with the exception of segment 0 Only segment 0 actually contacts the InfraStruXure Central server to retrieve the visible inventory through the Web Services interface Segment 0 writes the entire inventory to an intermediate file it places in the temporary directory defined by the TEMP variable If the Health Service is running as Local System this will be sSyste
11. a few parameters that are not directly related to the target specifically 1 the endpoint of the InfraStruXure Central server 2 the interval between script runs 3 the synchronization time of the runs and 4 the script timeout in seconds As with any workflow in Operations Manager the Management Pack allows the Operations Manager administrator to override values 2 through 4 to fit any particular need These overrides carry with them special potential consequences that must be understood and taken into account when you specify the overrides Consider the following example The default configuration sets the Device State Health Monitor to run every 5 minutes with no synchronization time and a 15 minute timeout You have three different groups of devices that you have created High Importance Medium Importance and Low Importance You override the monitor interval specifying every 5 minutes for High Importance devices every 15 minutes for Medium Importance devices and every hour for Low Importance Devices Because of the design of the system as described above the ability for Operations Manager to cook down the Check the Device State script has been reduced to one run for each group This is because one of the overridden values is a configuration parameter of the script As such Operations Manager must run the script once for each unique set of configuration parameters Although logically you have separated the devices int
12. al Servers on Proxy Health Services on page 7 for more information Operations Manager 2007 Management Pack for InfraStruXure Ceniral Changing the Default Management Pack Behavior Using an Overrides Management Pack The Management Pack installs in a dormant state and with a minimum monitoring configuration enabled by default An optional unsealed Overrides Management Pack is included in the installation package it enables everything defined in the Management Pack Activating the Overrides is acceptable in a test and evaluation environment however it is imperative that the activities of the Management Pack are completely understood before using this configuration in a production environment Follow this procedure to control the introduction of this Management Pack into your environment 1 N Import this Management Pack into a test environment Create a custom Management Pack for overrides or use the included optional Overrides Management Pack Create a group for the entities targeted by each set of rules you wish to enable or disable Create overrides that target the aforementioned groups Export this custom Management Pack Import the sealed Management Pack with the custom Management Pack into the production environment Populate the groups as required Specifically the following components are disabled by default The InfraStruXure Central Registration discovery This discovery targets computers running
13. argets on that InfraStruXure Central server For the Device State Health Monitor for instance the script returns the Device State for all devices on an InfraStruXure Central server Because the data set contains State for multiple devices each data point also contains the device element ID This causes Operations Manager to feed each data point in the data set to each workflow in the pipeline in this case the three filters for each device To compensate for the lack of specificity in the data source module the filters for each health state are more complex than usual Instead of evaluating only the state returned they evaluate that the device element ID matches the target of any given workflow and the state matches the state of that workflow plus some other criteria that are not directly related to cook down Although this step only shifts the burden to the filter it profoundly reduces the overall impact of the monitor Only one set of transactions is made with the InfraStruXure Central server Only one script is run which requires a separate process and is generally the most resource intensive type of operation in Operations Manager The bulk of the burden is borne by other module types such as filters that are implemented in native or managed code dlls and that are tightly integrated and optimized internal to the Health Service The underlying data source module is not specific in its configuration It is only passed
14. discovery rule runs on a Health Service Event 2720 marks the start of the discovery event 2721 marks the end When this discovery completes all InfraStruXure Central servers registered on the Health Service should be discovered though they will not have any inventory or health state Events 2722 and 2723 are logged when segment 0 of the inventory discovery rule runs on a Health Service Event 2722 marks the start of the discovery event 2723 marks the end When this discovery completes the inventory for the InfraStruXure Central server should be at least partially present in Operations Manager Event 2724 is logged by all scripts and signifies a general exception that the script encountered This event will be logged with the script name an internal function name a descriptive message and the contents of the exception Event 2729 is similar to 2724 but is logged specifically when an exception is encountered during a transaction with an InfraStruXure Central server s Web Services interface The same content is logged with the message as with event 2724 but the message may also include the XML involved in the transaction Operations Manager 2007 Management Pack for InfraStruXure Ceniral 15 Appendices Appendix 1 Included Sensor Types ISXCSensorType AIRFLOW Operations Manager ClassType com apcc ISXC ISXCSensor Airflow ALARM_STATUS AC ALARM_STATUS ENVIRONMENT com apcc ISXC ISXCSensor State com apcc ISXC ISXCSen
15. e for each user account e Assign the Run As profile that installs with the Management Pack to the four user accounts using a different user name for each of the four Health Services on which you would like to partition the load For example On SERVER assign User1 to the APC ISX Central Login Run As Profile On SERVER2 assign User2 to the APC ISX Central Login Run As Profile On SERVER3 assign User3 to the APC ISX Central Login Run As Profile On SERVER4 assign User4 to the APC ISX Central Login Run As Profile Setting the Environment Variable ISXCUI In order to use certain console tasks defined in the Management Pack register the install location of the InfraStruXure Central client application using a system environment variable The variable should be named ISXCUI and should be set to the full pathname of the folder that contains the InfraStruXure Central Client Do not use the full pathname of the client executable You must use the full pathname of the folder that contains that executable to enable the Launch ISX Central console tasks to locate the client executable Topics Related to Operations Inventory Discovery The second phase of the discovery the inventory discovery is targeted to each InfraStruXure Central server that is discovered by the registration discovery This discovery is scheduled to run every 30 minutes with the first run for any given InfraStruXure Central server occurring shortly after the
16. e type For both of these diagram views options have been set that streamline the display of these DA within the view The consequence of this is that the diagram view s tree ends at the device group or device type level These are leaf nodes that cannot be expanded to see the devices below them To further investigate the devices and sensors that are contributing to the overall health state of the leaf node right click on the leaf node and select Open Diagram View A new diagram view will open with the device group or device type as its root object The devices and sensors subordinate to the root object in the hierarchy will be visible in this diagram view Special Parameters for Monitor Overrides 12 Where possible monitors have been equipped with two parameters that you may override to finely tune the health state into which a given monitor enters due to the various states of the underlying InfraStruXure Central server UpgradeWarning and DowngradeCritical As their name implies these two Boolean true false values can upgrade warning conditions to critical conditions or downgrade critical conditions to warning conditions While Operations Manager provides the ability to override the severity of an alert generated from a monitor the severity of the underlying monitor is usually fixed This difference in severity can cause confusion in some cases when investigating the cause of an alert The alert will show one severity but the underlyi
17. ed by default as no meaningful state can be established as the default Operations Manager 2007 Management Pack for InfraStruXure Ceniral e Dependency Monitors Each InfraStruXure Central server has a dependency monitor that gathers the state of the devices it hosts and another dependency monitor that gathers the state of the device groups it contains Each device group has a dependency monitor that gathers the state of the devices in the group Each device has a dependency monitor that gathers the state of the sensors hosted by the device The management group wide group that contains all InfraStruXure Central servers has a dependency monitor that gathers the state of each InfraStruXure Central server Both dynamic DAs have dependency monitors that gathers the health of the component groups at lower levels of the hierarchy to their parent up to the root object Console Integration The Management Pack defines several views and tasks to provide the required window into the InfraStruXure Central server s inventory state e Views A state view that shows the state of all registered InfraStruXure Central servers on all Health Services is provided State detail columns are provided for the hosted device state and the contained device group state A state view that shows the state of all devices discovered on all InfraStruXure Central servers on all Health Services is provided State detail columns are provid
18. ed for the hosted sensor state for state bearing sensors only Three diagram views are provided with the All InfraStruXure Centrals group the root object of the By Device Group DA and the root object of the By Device Type DA as their root object respectively A performance view folder is provided with pre defined performance views for each data bearing sensor class type An environmental dashboard view is provided that displays a 2x2 matrix of the most common performance views e Tasks For an InfraStruXure Central server Tasks to launch the InfraStruXure Central client or a web browser to the InfraStruXure Central server For a device Tasks to launch the InfraStruXure Central client a Web browser to the InfraStruXure Central server or a Web browser to the device itself A special proxy URL is automatically selected to enable devices on the private network of an InfraStruXure Central server to be browsed 4 Operations Manager 2007 Management Pack for InfraStruXure Ceniral For a sensor Tasks to launch the InfraStruXure Central client a Web browser to the InfraStruXure Central server or a Web browser to the device that hosts the sensor A special proxy URL is automatically selected to enable devices on the private network of an InfraStruXure Central server to be contacted e Images Wherever possible images have been provided for the class types discovered by the Management Pack This include
19. generate Operations Manager events for every alarm raised on an InfraStruXure Central server These rules are enabled by default it is only the alert rules that are disabled by default It is strongly recommended that your create a group containing devices and or sensors or multiple groups in the overrides Management Pack and enable the desired rules for those groups See Optimizations to Reduce Impact and the Effect of Overrides on page 13 for an important discussion regarding the ramifications of certain overrides for these rules Operations Manager 2007 Management Pack for InfraStruXure Ceniral Another important override to consider is the TimeoutSeconds parameter defined for rules and monitors The default value for all workflows is 15 minutes 900 seconds As the device count of an InfraStruxure Central server grows the time required by these scripts increases and may exceed 15 minutes You will be alerted to this condition by the standard Operations Manager alerts When notified you will need to override the TimeoutSeconds parameter This condition is not affected by the number of devices visible to the Health Server but is dependent on the total number of devices managed by the InfraStruXure Central server See Partitioning Large InfraStruXure Central Servers across Multiple Health Services on page 9 for more information See Optimizations to Reduce Impact and the Effect of Overrides on page 13 for an impo
20. he Management Pack which is to set the last collection date and time to the current date and time when the collection rules first run This prevents historical alarms from being brought into Operations Manager but allows future alarms to be imported There are certain circumstances under which you may need to change this value for an InfraStruXure Central server e With the registration of an InfraStruXure Central server you wish to specify a date and time from which historical alarms should be collected on the first run e You experience an issue related to the configuration sets that result from a certain combination of overrides as described in the Optimizations to Reduce Impact and the Effect of Overrides on page 13 and wish to reset the collection to a prior date and time after correcting the issue 8 Operations Manager 2007 Management Pack for InfraStruXure Ceniral In these cases you may use the registration tool to specify the date and time from which the Management Pack should collect alarms the next time it does a collection 1 Start the registration tool 2 Click on the row containing the InfraStruXure Central server for which you wish to change the last collection date and time 3 Click the Advanced button 4 Specify the date and time the Management Pack should use the next time it collects alarms Creating Run As Accounts and Assigning Them to the Run As Profile After registering the InfraStruXure Central ser
21. illing Down on Distributed Application DA Diagrams 12 Special Parameters for Monitor Overrides 12 Optimizations to Reduce Impact and the Effect of Overrides 13 Script Events Generated by the Management Pack 15 Appendices ii ieee eee eek eee eee eed ea ee 16 Appendix 1 Included Sensor Types 02eeeeee eres 16 Operations Manager 2007 Management Pack for InfraStruXure Ceniral Introduction The APC InfraStruXure Central server is a network appliance that collects data from and monitors status of devices that support data center critical infrastructure The Microsoft System Center Operations Manager 2007 Management Pack provides a tight integration between the physical infrastructure space for which InfraStruXure Central provides unprecedented visibility and control and the systems infrastructure space for which Operations Manager provides the same type of solution Events from the physical infrastructure space can be viewed side by side with the system events to which they may be related providing an ability to predict respond to and prevent issues in the physical infrastructure from affecting system and application availability The Management Pack integrates with InfraStruXure Central version 5 1 and higher through the new Web Services interface Integration Concepts Inventory Integration Service Model The Management Pack integrates the inventory of InfraStruXure Central server
22. mRoot temp If the Health Service is running as any other account this will be that account s temporary directory Operations Manager 2007 Management Pack for InfraStruXure Ceniral This file includes directives for the class instances and properties for device groups device group members devices and sensors It also includes segment directives with the directive to start segment 0 being the first line in the file As segment 0 writes the contents of this file to disk it estimates the contribution each directive will have on the size of the resultant discovery data item When this estimate approaches 4M it writes a directive to start the next segment in order and resets the estimate The net effect is that the intermediate file will be split into segments that roughly divide the discovery into segments that should be well under the 4M limit All segments read this master intermediate file and create their own copy with only the directives specific to that segment being included This includes segment 0 which proceeds to this step after it completes the inventory and writes the master intermediate file All segments including segment 0 then process this file and create their discovery data item Segment 0 will re write the master intermediate file every time it runs It attempts to minimize the amount of time the file is in an inconsistent state by writing the new file using a temporary file name and then deleting the original and immedia
23. mely capacity and outstanding data in a workflow To mitigate these issues the Management Pack allows multiple Health Services to manage a single InfraStruXure Central server by utilizing device groups and restricted user accounts As an example consider an environment that has a single InfraStruXure Central server that manages 500 devices In testing you discover that the activity from this InfraStruXure Central server overwhelms the Health Service You can partition this InfraStruXure Central server to be managed by multiple Health Services by using the following method e Create device groups on the InfraStruXure Central server and split the device inventory among the device groups For example Group 1 through Group 4 with 125 devices each e Create four restricted logins on the InfraStruXure Central server User1 through User4 and assign them rights to only Group 1 through Group 4 respectively e Use the registration utility to register the InfraStruXure Central server on four different servers for example SERVER1 SERVER2 SERVER3 and SERVER4 While the name and FQDN can be identical across Health Services the proxy Health Service is a key field it is recommended that you appropriately tag the InfraStruXure Central server name in a way that uniquely identifies the partition e g a number Operations Manager 2007 Management Pack for InfraStruXure Ceniral e Create four Simple Authentication Run As accounts in Operations Manager on
24. mend that the name be descriptive and clear as it will be used in the Operations Manager object paths e To remove an InfraStruXure Central registration highlight the row of the registration and click Remove The registry is updated immediately e To set the collection date for an InfraStruXure Central server highlight the row of the registration and click Advanced See Registry Use in Alarm Collection on page 8 for more information All registry changes are made in the key HKEY LOCAL MACHINE Software APC MsScOpsMgrMpForIsxc e The registered names appear as the REG_SZ values Name0 Name lt n gt e The registered FQDNs appear as the REG_SZ values FODNO FODN lt n gt e These values must be consecutively numbered from 0 Registry Use in Alarm Collection The four rules that collect alarms from an InfraStruXure Central server use the registry of the Health Service to manage the collection process by storing the date and time of the last collection in the registry This date and time expressed in the XML date and time format is used as the starting point for the next collection This information is stored under the key HKEY_LOCAL_MACHINE Software APC MsScOpsMerMpForlsxc AlarmCollection e The last collection date appears as a REG_SZ value named for the FQDN of the InfraStruXure Central server it represents The value is the XML formatted date and time value Under normal circumstances you can accept the default behavior of t
25. more details Each sensor is also targeted by a pair of rules that collects alarms that have been generated since the last collection and e Inserts them into the Operations Manager operational database and data warehouse for display in event views and reports e Optionally generates an alert for each alarm This rule is disabled by default All sensor types except state sensors are also targeted by a rule that collects the data point for that sensor and inserts it into the operational database and data warehouse for display in performance views or reports Each state sensor is targeted by a monitor that reads the sensor data point and maps it to a health state There are two variants of this monitor e Pre Defined This monitor will only have an active health state for sensor types whose data point represents a state that is well defined and has a fixed mapping of its state values to Operations Manager health states e User Defined This monitor will only have an active health state for sensor types whose data point represents a state that is undefined outside of a user provided context The user can establish regular expression patterns to determine which states should be considered Healthy Warning and Normal An example of such a state sensor is a generic switch sensor Depending on the switch and the application a state of open closed etc could be normal or cause for warning or a critical condition This monitor is disabl
26. ng monitor states in the Health Explorer will show another severity These parameters allow the state of the underlying monitor to be changed While it is still possible to override the severity of the alert the alert severity can be left to follow the monitor severity in most cases Most monitors defined in the Management Pack use a pre defined mapping to reflect the underlying entity state in the Operations Manager monitor health state Given these two parameters you can change this behavior The net effect of these parameters is given in the following matrix Upgrade Warning DowngradeCritical Net Effect False Default False Default The health state of the monitor will be the health state mapped by the Management Pack from the state of the underlying device or sensor in InfraStruXure Central True False Default All abnormal states of the underlying device or sensor in InfraStruXure Central will be represented as Critical in the health state of the monitor False Default True All abnormal states of the underlying device or sensor in InfraStruXure Central will be represented as Warning in the health state of the monitor True True Warning states will be Critical and Critical states will be Warning Use this option only under unique conditions where the configuration warrants it Operations Manager 2007 Management Pack for InfraStruXure Ceniral Optimizations to Reduce Impact and the Effect of Ove
27. o three groups the script is designed to collect the device state for all devices The overall operation of the monitor will still be intact however For the High Importance devices the script will return the state for all devices every 5 minutes but the filters will ensure that only those device element IDs actually targeted in this group are affected The same is true for the Medium Importance devices and Low Importance devices Operations Manager 2007 Management Pack for InfraStruXure Ceniral Therefore although you have separated the devices and have alleviated Operations Manager from evaluating the monitor on the Medium and Low Importance devices so frequently the script that runs every 5 minutes still does the same amount of work In fact since you are running one script every 5 minutes two every 15 minutes the 5 and 15 and three every 60 minutes the 5 15 and 60 you have actually increased the number of transactions that run against the InfraStruXure Central server e For most workflows this number of transactions will be acceptable The benefits of cooked down scripts far outweigh the overhead incurred when the cook down is counteracted by varying configuration sets caused by overrides Caution If overrides are specified for very small groups or even individual devices or sensors and with even slightly different values the script could be forced to run AN collecting all data points but only being used by
28. om apcc ISXC ISXCSensor State VOLUME_AIRFLOW com apcc ISXC ISXCSensor Airflow Operations Manager 2007 Management Pack for InfraStruXure Ceniral 17 APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways e Visit the APC Web site to access documents in the APC Knowledge Base and to submit customer support requests www apc com Corporate Headquarters Connect to localized APC Web sites for specific countries each of which provides customer support information Www apc com support Global support searching APC Knowledge Base and using e support e Contact the APC Customer Support Center by telephone or e mail Local country specific centers go to www apc com support contact for contact information For information on how to obtain local customer support contact the APC representative or other distributors from whom you purchased your APC product 2009 APC by Schneider Electric APC the APC logo and InfraStruXure are owned by Schneider Electric Industries S A S American Power Conversion Corporation or their affiliated companies All other trademarks are property of their respective owners eee LUMI ee
29. ot be discovered until the second discovery cycle The initial discovery cycle will discover the inventory that fits into the initial 4M discovery data item segment 0 The remainder of the segments will terminate and not produce discovery data until the second cycle This behavior is a consequence of the discovery data item size limit and the lack of synchronization facilities between workflows International Characters in Inventoried Properties Because the InfraStruXure Central interface uses Web Services that are accessed from Operations Manager using a script the output of the script is available in ANSI characters only The output is converted to the UTF 8 encoding upon being picked up from the script by Operations Manager While international characters will import properly some character sets that are double byte only UTF 16 etc will not import correctly The data will import but will be represented as question mark characters in Operations Manager There is no work around for this limitation Operations Manager 2007 Management Pack for InfraStruXure Ceniral 11 Drilling Down on Distributed Application DA Diagrams The Management Pack installs with several pre defined views among them two special diagram views for the two dynamic Distributed Applications that the Management Pack creates One DA is the hierarchy of InfraStruXure Central servers by device group the other is the hierarchy of InfraStruXure Central servers by devic
30. rrides The scripts defined in this Management Pack that collect device and sensor state and data take advantage of Operations Manager s ability to cook down a script This applies to every script that is used in a workflow targeted to a device or sensor which includes the following Device Alarm Health Monitor Collection Rule for Device Alarms Alerting Rule for Device Alarms Device State Health Monitor Sensor Alarm Health Monitor Collection Rule for Sensor Alarms Alerting Rule for Sensor Alarms Sensor State Health Monitor Sensor State Monitor Pre Defined Sensor State Monitor User Defined This design prevents Operations Manager from requiring a separate invocation of any particular script for each instance of a device or sensor If this were not done in large environments the Health Service could be required to run literally thousands of scripts each polling cycle This would be an undue strain on the InfraStruXure Central server the Health Service and the entire Operations Manager Management Group To understand how this design mitigates this risk it is necessary to understand the anatomy of these workflows Consider the Device State Monitor workflow as an example The Device State Health Monitor targets an InfraStruXure Central device and has three states Healthy Warning and Critical Therefore for each device three independent workflows will be required Check the Device State Filter for Healthy State Set the
31. rtant discussion regarding the ramifications of certain overrides for these rules Registering InfraStruXure Central Servers on Proxy Health Services The initial discovery that generates the first instances of class types defined in this Management Pack is the registration discovery This discovery is targeted to computers running Windows Server i e the Microsoft Windows Server Computer Operations Manager class and runs every 15 minutes It discovers the registry keys that are written by the registration tool and maps them to instances of the corresponding ISX Central class types It also defines the management relationship between the Health Service and any InfraStruXure Central servers This ensures that all subsequent activities related to the InfraStruXure Central server are processed by the same Health Service that discovered it The registration discovery also discovers component groups that mirror the InfraStruXure Central server itself which are subsequently linked to the two Dynamic Distributed Application root objects by a separate discovery rule that creates containment relationships between them Any InfraStruXure Central server that is registered on a Health Service will be managed from that Health Service All transactions with the InfraStruXure Central web services interface will be conducted from that Health Service You must register the InfraStruXure Central servers that will be monitored on the Health Services that will be
32. s e Images for each device type e Images for each sensor type e Images for the InfraStruXure Central server e Images for device groups e Images for the dynamic DA Component Groups e Images for the All ISX Centrals group and DA root objects Initial Setup Installation To install the Management Pack install the msi package downloaded from the APC Web site http www apc com tools download into an appropriate directory The installation package consists of four files this document the sealed Management Pack mp the optional Overrides Management Pack xml and the registration utility exe Only the sealed Management Pack is required for import Perform the installation on a system running the Operations Manager console The Management Pack references only built in Operations Manager Management Packs but requires at least Operations Manager 2007 SP1 The registration utility is run on each Health Service that will act as a proxy between Operations Manager and InfraStruXure Central The registration utility is a tool that provides a user interface to set certain registry keys that are used by the Management Pack to perform the initial discovery of the InfraStruXure Central servers that should be managed from that Health Service Therefore the installation should also be performed on the systems that will act as proxy unless you intend to manage these registry keys by some other means See Registering InfraStruXure Centr
33. s in your environment and the inventory that they host using a two part discovery process The first part discovers all InfraStruXure Central servers that are registered on a given Health Service and is called the Registration Discovery The second part discovers the inventory of each InfraStruXure Central server In this document we will make frequent references to Health Service The initial discovery is actually targeted at computers running Windows Server the Microsoft Windows Server Computer Operations Manager class type but it is the Health Service running on that server that is the primary component that performs the functions dictated by this Management Pack The inventory discovered is defined as follows e For each Health Service for which the Registration Discovery is enabled An object representing each registered InfraStruXure Central server Each object becomes the target of several monitoring rules the host for all devices and the container for all device groups An object representing each registered InfraStruXure Central server key properties only as a Component Group for the By Device Group Dynamic Distributed Application An object representing each registered InfraStruXure Central server key properties only as a Component Group for the By Device Type Dynamic Distributed Application e For each discovered InfraStruXure Central server Objects representing every device group hosted device and
34. sor State ANALOG BATTERY_REPLACEMENT com apcc ISXC ISXCSensor Generic com apcc ISXC ISXCSensor State CAMERA MOTION COOLANT_LEVEL com apcc ISXC ISXCSensor State com apcc ISXC ISXCSensor State COOLING_DEMAND COOLING_OUTPUT com apcc ISXC ISXCSensor Power com apcc ISXC ISXCSensor Power DOOR_SWITCH EXTERNAL_CONTACT com apcc ISXC ISXCSensor State com apcc ISXC ISXCSensor State EXTERNAL_HUMIDITY com apcc ISXC ISXCSensor Humidity EXTERNAL_TEMPERATURE com apcc ISXC ISXCSensor Temperature FRONT_DOOR_HANDLE_STATUS com apcc ISXC ISXCSensor State FRONT_DOOR_LOCK_STATUS com apcc ISXC ISXCSensor State FRONT_DOOR_STATUS com apcc ISXC ISXCSensor State GENERATOR_MODE com apcc ISXC ISXCSensor State GENERATOR_STATUS com apcc ISXC ISXCSensor State INPUT_CURRENT com apcc ISXC IS XCSensor Current INPUT_FLUID_TEMPERATURE INPUT_VOLTAGE com apcc ISXC ISXCSensor Temperature com apcc ISXC IS XCSensor Voltage INTEGRATED_HUMIDITY INTEGRATED_TEMPERATURE com apcc ISXC ISXCSensor Humidity com apcc ISXC ISXCSensor Temperature LOWER_INLET_TEMPERATURE MAIN_INPUT_BREAKER com apcc ISXC ISXCSensor Temperature com apcc ISXC ISXCSensor State MIDDLE_INLET_TEMPERATURE OIL_LEVEL com apcc ISXC ISXCSensor Temperature com apcc ISXC ISXCSensor State ON_BATTERY_STATE com apcc ISXC ISXCSensor State ON_BYPASS_STATE com apcc ISXC ISXCSensor State
35. tely renaming the temporary file All segments use this two step process of splitting the file first and then processing it to minimize the amount of time they have the master intermediate file open There are retries built into the process Warning Events on Initial Inventory Discovery Since there are no mechanisms for inter workflow synchronization there is one race condition that occurs on the first discovery cycle for a new InfraStruXure Central server on a Health Service This also occurs on the first discovery after the temporary directory is cleared if that happens All segments except segment 0 will attempt to open the master intermediate file Since it may take segment 0 much longer to create this file than is prudent for the other segments to wait they will log a 2724 event in the Operations Manager log and exit without creating a discovery data item This will also cause event 21405 to be logged by Operations Manager itself indicating that the module was expected to create a data item but did not The discovery process must terminate abnormally in this case On the initial discovery the discovery could return an empty discovery but if this condition is occurring because the temporary directory has been cleared an empty discovery would cause all objects for segments other than 0 to be deleted until the next discovery cycle Another consequence of this behavior is that the entire inventory for larger InfraStruXure Central servers will n
36. vers that will be monitored by the selected Health Services you must create the Run As accounts required to access the InfraStruXure Central servers and assign them to the Run As Profile that is defined in the Management Pack Each Health Service can be assigned a different Run As account You will need multiple Run As accounts in the following cases e If you are partitioning an InfraStruXure Central server across multiple Health Services discussed below e If multiple InfraStruXure Central servers do not share a common login account In this case multiple Health Services may be required to act as proxy for the different InfraStruXure Central servers This is because only one Run As account can be assigned to the Run As profile for a particular Health Service at one time To assign a Run As account to a health service s Run As profile you must select the Simple Authentication Run As option when creating the account Partitioning Large InfraStruXure Central Servers across Multiple Health Services Because there are inherent limits to the number of concurrent workflows that Operations Manager can run the Management Pack has been designed to require a minimum number of transactions with the InfraStruXure Central server This is called cook down and is covered in the section Optimizations to Reduce Impact and the Effect of Overrides on page 13 Cook down solves the problem of concurrent workflows but can introduce other issues na

Download Pdf Manuals