Home

Owner`s Manual - Cloudfront.net

image

Contents

1. INSTALLATION INSTALLATION When the unit is operating as an air conditioner heater or dehumidifier the unit draws in fresh outdoor air and exhausts hot air in AC or dehumidifier mode or cool air in Heat mode out of the room to complete the air exchange When the unit is operating in fan mode no outdoor air exchange takes place The window kit and exhaust hose do not need to be installed when the unit is used as a fan NOTE The supplied window kit can be installed in sliding windows and sliding glass doors up to 8 ft long approximate length MOUNTING THE EXHAUST HOSES Choose a suitable location near a grounded electrical outlet and suitable window or door Remove packaging and locate components Extend both ends of the exhaust hoses approximately 6 inches e Screw the window kit adapter onto one end of the exhaust hose clockwise e Screw the hose adapter onto the other end of the exhaust hose clockwise Repeat on the other exhaust hose Remove outlet covers from the back of the unit by screwing them counter clockwise then lifting up e Mount the exhaust hoses onto the back of the unit by locking the hose adapters into place DUAL HOSE WINDOW KIT INSTALLATION ASSEMBLY amp INSTALLATION Quickly and efficiently cool a large area The venting kit must be installed in order for the unit to work correctly in the air conditioning heating or dehumidifying mode The venting kit does not need to be used while the
2. THE CONTROL PANEL Air Conditioner Mode 1 Install the exhaust hoses and window kit properly see pages 5 6 amp 7 2 Plug the Power Cord into an electrical outlet 3 Turn on the unit by pressing the POWER button on the control panel 4 Press the Mode button until the 6 icon appears on the Multi color display 5 Press the Wor A buttons until the desired room temperature appears on the control panel display The temperature ranges from 61 F 88 F 16 C 31 C 6 Select the desired fan speed by pressing the FAN SPEED button 9 CONTROL PANEL DISPLAY amp OPERATING INSTRUCTIONS NOTE During hot days the unit will cool the room most efficiently by setting the tem perature at the lowest setting and the fan speed on high Reducing the length of the exhaust duct insulating the exhaust hose and window kit and keeping direct sunlight to a minimum will also improve the cooling efficiency NOTE When the unit is running on cooling mode the exhaust hoses are required and must be vented outside using the supplied window kit Dehumidifier Mode Install the exhaust hoses and window kit properly see pages 5 6 amp 7 Plug the Power Cord into an electrical outlet Turn on the unit by pressing the POWER Button on the control panel Press the MODE button until the appears on the control panel display um 4 2 3 4 NOTE The unit operates at low fan speed during dehumidifier
3. Track Panel WINDOW KIT C u ASSEMBLY 1 Take the track screws and screw one into each of the small holes found on the hose panels 2 Next take the wing nuts and tighten them around each of the track screws Do not tighten the wing nuts all the way make sure they are somewhat loose 3 Now place the sliding track panel over the track screw on hose panel 4 Next take the other hose panel and connect it to hose panel by placing the sliding track panel over the track screw on hose panel 5 The hose panels should now be connected using the sliding track panel 6 To complete the assembly tighten the wing nuts installed earlier The finished window kit should resemble the image seen below SINGLE HOSE EXHAUST amp WINDOW KIT INSTALLATION When you want quick spot cooling install the CR13000 PAC using the single hose window kit installation For Single Hose Installation Install only the left exhaust hose over the circular air outlet this outlet will be on the left side of the unit when you are facing the back of the unit Cover the right circular air intake using the exhaust intake cover After installing the hose remove the square air intake cover on the back of the unit and install the square air intake vent with removable washable filter a CLOS ik a Air Intake Cover Exhaust Hose Installed Air Intake Vent additional accessory For Single Hose Window Kit Installation To install the window kit f
4. finish of the case or other appearance parts caused by wear e Damage caused by repairs or alterations of the unit by anyone other than those authorized by ClimateRight Freight and Insurance cost for the warranty service ALL WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY CLIMATERIGHT DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT SHALL CLIMATERIGHT S LIABILITY EXCEED THE RETAIL VALUE OF THE UNIT FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THIS UNIT This warranty covers only new products purchased from our authorized dealers or retailers It does not cover used salvaged or refurbished products As some states do not allow the limitation or exclusion of incidental or consequential damages or do not allow limitation on implied warranties the above limitations and exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights that vary from state to state For Technical Support and Warranty Service Please Call Ph 800 725 4628 Or Write To 808 Rhoads Ave Columbus OH 43205 www climaterightair com 16
5. unit 1 Empty any excess water by unplugging the water drainage stop in the back of the unit located at the bottom 2 Unplug the unit 3 The unit should be stored in a cool dry place DISCLAIMER ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER S MANUAL ARE THE PRESENTATION OF THE MANUFACTURER CLIMATE RIGHT HAS NOT CONDUCTED INDEPENDENT TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN 15 WARRANTY One Year Limited Warranty ClimateRight warrants the accompanying ClimateRight Air Portable Air Conditioner with Heat Pump to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE 1 year from the date of original retail purchase in the United States If the unit exhibits a defect in normal use ClimateRight will at its option either repair or replace it free of charge within a reasonable time after the unit is returned during the warranty period As acondition to any warranty service obligation the consumer must present this Warranty Certificate along with a copy of the original purchase invoice THIS WARRANTY DOES NOT COVER e Damage accidental or otherwise to the unit while in the possession of a consumer not caused by a defect in material or workmanship Damage caused by consumer misuse tampering or failure to follow the care and special handling provisions in the instructions Damage to the
6. CLIMATERIGHT Portable Air Conditioner Questions or concerns For assistance please call Customer Service ClimateRight USA 808 Rhoads Ave Columbus OH 43205 www climaterightair com Ph 800 725 4628 OWNER S MANUAL Operating and Servicing Instructions CLIMATERIGHT CR13000 PAC PORTABLE AIR CONDITIONER with HEAT PUMP CLIMATERIGHT IMPORTANT READ CAREFULLY BEFORE ASSEMBLY AND USE Read and follow all safety rules and instructions before operating this equipment THIS PRODUCT IS INTENDED FOR HOUSEHOLD USE ONLY Please keep this manual for future reference CLIMATERIGHT CR13000 PAC Portable Air Conditioner with Heat Pump Thank you for choosing a ClimateRight product This owner s manual will provide you with valuable information necessary for the proper care and maintenance of your new product Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new ClimateRight Air Portable Air Conditioner with Heat Pump For your own records please attach a copy of your sales receipt to this manual Also write the store name location date purchased and serial number below Store Name Location IMPORTANT INSTRUCTIONS Before installing and using your portable air conditioner please read this owner s manual carefully Store this manual in a safe place for future reference 1 Always place the unit on a level surface 2 Never use or
7. ED button It is recommended to set the fan speed to low NOTE When heat mode is selected the unit will shut down for 3 5 minutes then start in heating mode NOTE When the unit is running on heating mode the exhaust hoses are required and must be vented outside using the supplied window kit gt gt 4 2 3 4 10 OPERATING INSTRUCTIONS Auto Mode 1 Install the exhaust hoses and window kit properly see pages 5 6 amp 7 2 Plug the Power Cord into an electrical outlet 3 Turn on the unit by pressing the POWER button on the control panel 4 Press the MODE button until the icon appears on the control panel display Select the fan speed by pressing the FAN SPEED button NOTE During AUTO mode the unit operates in Heating mode when the room temperature is below 68 F Dehumidifier mode when the room temperature is between 68 F to 80 F And Air Conditioner mode when the room temperature is above 80 F Sleep Mode This mode can only be selected when using the Remote control 1 To set Sleep mode make sure the unit is in Air Conditioner mode or Heating mode 2 Press the SLEEP Button on the remote control The y icon appears on the control panel display 3 When in SLEEP mode the fan will run on low to keep fan noise at a minimum 4 When in Air Conditioner mode the temperature setting will gradually increase to 2 F above the original set temperature for 6 hours After 6 hours th
8. e temperature setting will return to the set temperature 5 When in Heating mode the temperature setting will gradually decrease to 2 F below the original set temperature for 6 hours After 6 hours the temperature setting will return to the set temperature 6 When in Dehumidifier mode the temperature will not change when Sleep mode is selected Compressor Indicator The N icon will light up on the control panel display when the compressor turns on The 41 icon will turn off when the compressor shuts off 11 CONTROL PANEL DISPLAY amp OPERATING INSTRUCTIONS Emergency Condensate Holding Tank When the room temperature is low and the indoor humidity is high the air conditioner may not be able to evaporate some of the moisture fast enough When this happens the water will accumulate in an emergency condensate tank inside the unit Once the emergency condensate tank is full the unit will automatically shut off and the Y7 will appear on the control panel display To empty the condensate tank unscrew the screw plug at the bottom back of the unit You will need a small pan approximately 1 high to catch the water coming out of the condensate tank Once the condensate tank is drained the unit will begin working within a few minutes The emergency condensate tank holds approximately 1 5 Liters of water Another option is to purchase a small hose from a hardware store that can fit around the 5 8 drain plug on t
9. he back of the unit and drain the unit into a gravity drain or larger pan for continu ous drainage To resume operation quickly empty the water container according to the following steps 1 Turn the unit off Do not move the unit when the water container is full 2 Place the drain pan accessory under the drainage port at the back of the unit 3 Remove the screw plug from the drain hole The condensate water will drain out automatically When the drain pan is full screw the screw plug back onto the drainage hole to stop the water flow Empty the drain pan Repeat until all the water is emptied Once the water container has been emptied screw the plug back onto the drain hole Do not allow the water to drip continuously into the drain pan as it might easily overflow Screw Plug Drain Hole 12 OPERATING THE UNIT USING THE REMOTE CONTROL LCD Display Mode eunen Power Button Fan a Speed A Temp Setting Swing AU ei re mN Louver Oscillation LA Timer On ie Timer Off u Minute Selector cr CLIMATERIGHT REMOTE CONTROL OPERATING INSTRUCTIONS 1 Power On and Off If the unit is already on press the POWER I O button on the remote while point ing the remote away from the unit This will turn the remote on If the unit is off now press the POWER 1 0 button once to manually turn the unit on Press the Power button once more to turn the unit off When you press the POWER button the upper right square o
10. ith a beep sound from the unit The remote control will not display AUTO under the speed label Once Auto fan speed is selected the unit will beep and there will not be a fan speed displayed on the remote control 4 Temperature Setting When the unit is in Air Conditioner or Heating mode you can select your desired temperature Press the Y or A to select your desired temperature setting The temperature on the LCD dis play on the remote control will increase or decrease accordingly Pressing the w and A buttons simultaneously will change the temperature select between F and C 5 SLEEP MODE See SLEEP MODE on page 11 6 SWING To turn on the oscillation press the SWING button on the remote control Once you press SWING the louvers on the unit will oscillate up and down The bottom left square of the remote control display will show the gt icon when oscillation SWING is selected 7 TIMER To program the timer first press the T ON button Once T ON is pressed the auto on timer will blink in the bottom right rectangle of the remote control display Press the MIN and HOUR buttons to change the clock to the desired time for the unit to automatically turn on The minutes will increase by 10 with each press of the MIN button and the hours will increase by 1 with each press of the HOUR button Press the T OFF button and the remote control display will flash the desired auto off timer Press the MIN and HOUR but
11. mode The unit cools room slightly during the dehumidification Keep the windows and doors closed to aid the effectiveness of the unit in removing the moisture from the room NOTE When the unit is running on dehumidifier mode the exhaust hoses are required and must be vented outside using the supplied window kit NOTE The unit will not perform in dehumidifier mode when the room temperature is lower than 61 F Fan Mode 1 Plug the Power Cord into an electrical outlet 2 Turn on the unit by pressing the POWER button on the control panel 3 Press the MODE button until the icon appears on the control panel display 4 Select the fan speed by pressing the FAN SPEED button 5 To circulate more air press the SWING button on the remote control The louvers will oscillate which moves the louvers up and down to increase air circulation NOTE It is not necessary for the exhaust hoses and window kit to be installed to operate the unit in fan mode Heating Mode Install the exhaust hoses and window kit properly see pages 5 6 4 7 Plug the Power Cord into an electrical outlet Turn on the unit by pressing the POWER button on the control panel Press the MODE button until the AR icon appears on the control panel display 5 Press the Y or A buttons until the desired room temperature appears on the control panel display The temperature ranges from 61 F 88 F 16 C 31 C 6 Select the fan speed by pressing the FAN SPE
12. n the remote control LCD Display will light up When in Air Conditioner Heating and Auto mode the selected temperature will appear on the remote control display When the unit is in Fan mode and Dehumidifier mode you will see the icon instead of the set temperature This shows that temperature selec tion is not available when the unit is in Fan or Dehumidifier mode 13 CONTROL PANEL DISPLAY amp OPERATING INSTRUCTIONS 2 Mode Selection Press the MODE Button repeatedly to cycle between the different modes Auto Air Conditioner Dehumidifier Fan only and Heater mode The upper left square on the Remote control dis play will light up showing which mode is selected In Air Conditioner mode the display will show COOL in Heating mode the display will show HEAT in Dehumidifier mode the display will show DRY in Fan mode the display will show FAN and in Auto mode the display will show AUTO 3 Fan Speed Press the FAN speed button to cycle through high medium and low fan speeds The dis play on the remote control will show High Medium Low under the SPEED label on the remote control LCD display There is an additional auto speed setting that is enabled in only heating and cooling modes This speed is next setting after low when pressing the FAN speed button on the remote control The speeds will cycle through in this order High Medium Low Auto Each change in speed will be associated w
13. ollow the same directions on page 6 for dual hose installation but instead of using the dual hose window kit panel use the single hose panel pictured below Single Hose Window Kit Panel CONTROL PANEL DISPLAY amp OPERATING INSTRUCTIONS Control Panel Temp amp Timer Selection Swing Button Fan Speed Button TMERON TIMER OFF Sie vw A FAN SPEED WODE POWER Timer Buttons Temp Select Mode Button Power Button A Fan Speed Multi Color Display Auto A C Heat en Temp amp Timer Indicator Oscillation On Off CLIMATE Bucket Full Timer On Timer Off Compressor On Off OPERATING INSTRUCTIONS CONTROL PANEL BUTTONS 1 Power On and Off Press the POWER button once to manually turn the unit on Press the POWER button once more to turn the unit off 2 Mode Selection Press the MODE Button repeatedly to cycle between the different modes Auto mode Air Conditioner Dehumidifier Fan only and Heater 3 Fan Speed Control Press the FAN SPEED Button to cycle through the different fan speeds High Medium and Low The fan speed can be visually distinguished by the speed of the fan icon on the front panel There is an additional auto speed setting that is enabled in only heating and cooling modes This speed is next setting after low when pressing the speed control button The speeds will cycle through in this order High Medium Low Auto Each change in speed will be associated wi
14. ource via electrical disconnect circuit trip if the nominal current leakage between the cord shield and either load conductor exceeds a predetermined value The cord will remain de energized until the devise has been manually reset This is intended to reduce the risk of a fire in the power cord or combustible materials nearby The cord shields are not grounded and they must be considered a shock hazards if exposed The cord shield must not be connected to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet 2 Press TEST Button circuit should trip cutting power to the air conditioner 3 Press RESET button for use If test button is pressed and unit can still be turned on current leakage has been detected Do not use the air conditioner or attempt to reset the LCDI Plug Contact ClimateRight Customer Service for troubleshooting recommendations RESET TEST WARNING 1 DO NOT press the TEST button while the air conditioner is operating 2 The TEST and RESET buttons should not be used as ON and OFF switches 3 The cord and plug are not intended to offer protection to externally connected loads or supply circuits 4 The cord and plug are intended for indoor use only PARTS AND ASSEMBLY EXHAUST HOSES Exhaust Hose Hose Adapter Window Kit Adaptor WINDOW KIT ASSEMBLY 8
15. se Installation Additional Accessory 1 Owner s Manual SPECIFICATIONS The cooling capacity is measured at an ambient temperature of DB 86 F WB 78 F e Noise level is measured at a distance of 3 28 ft away from the front of the unit when the unit is in cooling mode Power consumption is measured when the fan runs at the highest speed setting These specifications are for reference only For actual data please refer to the rating label on the back of the unit If the environment temperature is higher than the max operating temperature or lower than the minimum operating temperature the air conditioner may not work properly Model Cooling Capacity Heating Capacity Dehumidifier Capacity Power Cooling Heating Air Flow Volume Power Source Noise Level Net Weight Operating Temp Cooling Heating Product Dimensions Refrigerant CR13000 PAC 13 000 BTU H 12 500 BTU H 60 pts day 1390W 1180W 225CFM 115 V 60 HZ 11 12 5 AMP Heating Cooling 46dB A 88 lbs 60 8 F 107 6 F 23 F 89 6 F TASA SES x81 7 R 410A LCDI POWER CORD AND PLUG This air conditioner is equipped with an LCDI Leakage Current Detection and Interruption power cord and plug as required by US National Electric Code 440 65 This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side The LCDI power cord and plug will remove the supply s
16. store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual 3 Maintain at least 10 inches 25 cm clearance space around this unit Do not block or cover air inlet or outlet grilles The unit must be connected to a correctly grounded power supply Do not start or stop the unit by inserting or pulling out the power plug Do not use an adapter plug or extension cord N Do not use the unit in the immediate surroundings of a bath a shower or a swimming pool 8 Do not insert anything into the air outlet Do not obstruct air inlet or outlet grills unless instructed by this manual 9 Do not let children play near this unit 10 Always inspect the cord for signs of damage before use If the power cord is damaged it must be replaced by the manufacturer or a qualified service technician 11 When cleaning the unit always turn the unit off and unplug the power cord 12 When the unit is not in use always remove the venting kit from window 13 Do Not Mix Old And New Batteries Do Not Mix Alkaline Standard Carbon Zinc or Rechargeable Nickel Cadmium Batteries PACKAGE CONTENTS Model CR13000 PAC Portable Air Conditioner Unit 1 Exhaust Hoses 2 Hose Adapters 2 Window Kit Adapter 2 Air Intake and Outlet Covers 2 Remote Control 1 AAA Batteries 2 Window Kit 4 Sliding Panels 1 dual hose panel 1 single hose panel 2 extension panels Air Intake Vent for Single Ho
17. th a beep sound from the unit 4 Temperature Select the desired temperature by pressing either W or A key when using the unit in cooling or heating mode The temperature indicator flashes to display the desired temperature setting After the temperature is set the unit will display this temperature setting until it is changed by the user The multi color display shows temperature in Celsius or Fahrenheit Pressing the W and A buttons simultaneously will change the temperature select between F and C 5 Timer To program the timer press the TIMER ON button until the display shows a flashing B Press the w or A buttons to change the clock to the desired time for the unit to automatically turn on Press the TIMER OFF button and the display on the unit will flash B o Press the y or A buttons to change the clock to the desired time for the unit to automatically turn off The TIMER OFF indicator will flash for 3 seconds to activate the times you programmed NOTE The timer will also remember your settings when it is set If you set the timer while in Air Conditioning mode the timer will automatically turn the unit on and off in air conditioning mode according to the desired programmed times The timer will also remember the temperature settings fan speed and oscillation setting The timer works when the unit is in Air Conditioner mode Heating mode Dehumidifier mode Fan mode and Auto mode OPERATING THE UNIT USING
18. tons to change the clock to the desired time for the unit to automatically turn off The timer is set when the auto off time stops flashing and the words ON and OFF are displayed next to the time 8 CLOCK To set the clock on the remote control hold down either the MIN or HOUR button until the displayed time flashes on the remote control display Change the minutes by pressing the MIN button and change the hours by pressing the HOUR button 14 MAINTENANCE Note Make sure power is off and the power cord is not plugged into an electrical outlet prior to performing any maintenance on the unit Clean or replace filter If the air filter is blocked with a dust the airflow volume may reduce It is recommended to clean the filter once every two weeks or as needed 1 Remove the filter from the filter compartment on the back of the unit 2 Wash the air filter by immersing it gently into warm water with a neutral detergent Rinse the filter and dry it thoroughly out of sunlight 3 Slide the filter back into the filter compartment after it is thoroughly dried 4 If the filter is torn or unusable order a new filter by calling the customer service number on the warranty page of this manual Clean the unit housing 1 Keep the unit from being exposed directly to the sun to prevent color fading 2 Clean the surface with a damp cloth and dry it with a soft towel Storing the Unit for an Extended Period of Time or Transporting the
19. unit is fanning The window kit has been designed to fit into most vertical and horizontal window openings The window kit can also be used in a sliding door 1 Choose a suitable location near a grounded electrical outlet and a suitable window or door Remove packaging 2 Remove the outlet covers from the back of the unit by screwing them counter clockwise then lifting up 3 Pull out one end of the exhaust hose then screw on the adapter clockwise Repeat on other exhaust hose 4 Pull out the opposite end of the exhaust hose then screw on the window kit adapter clockwise Repeat on other exhaust hose 5 Mount the exhaust hoses onto the back of the unit 6 Open the window or door and adjust the length of the window kit to fit the opening If necessary mark the kit and cut down one end to properly fit the opening 7 Attached the window kit adapters to the window kit Close the window or door tightly Your Portable Air Conditioner is now ready to cool NOTE When using the venting system keep the exhaust hose as short and straight as possible The exhaust hose can be shortened but it is not recommended to increase the length of the exhaust hose Do not use an extension cord with your portable air conditioner When using to a sliding door it is recommend to make the air outlet up to air inlet WINDOW KIT ASSEMBLY PARTS A 2 Track Screws C 2 Hose Panels one with Two Exhaust Hose Openings B 2 Wing Nuts D 1 Sliding

Download Pdf Manuals

image

Related Search

Related Contents

Forms_files/CTvol users guide v2.0  Embedded Linux USB Driver User Guide  Betriebsanleitung Tellerstapler  SISTEMA DE SEGURIDAD LYNX TOUCH  Handheld ECG Monitor  TPR-2000H  Troubleshooting Troubleshooting  Lightolier C3MRPD User's Manual  MANUAL DE INSTRUCCIONES Adaptador de Temperatura para  note méthodologique SU1.04.01  