Home
Expansion Module Firmware Upgrade Procedure
Contents
1. Expansion Module Firmware Upgrade Procedure Expansion Module Firmware Upgrade Procedure These are instructions for upgrading the SMARTDAC expansion module firmware Please read this document before proceeding with the upgrade Applicable Products GX90EX standard models only Excludes special specifications with suffixes of S1 999 or Z Note that in factory maintenance is required for those models Versions after Upgrade GX90EX R1 02 01 Items to Prepare GX GP main unit m GX GP version R2 01 01 or later with the GX90EX installed m SD memory card Be sure to use the GX GP main unit or SD card formatter software available from the SD Association to format the SD memory card Other formats are not supported by the firmware upgrade m GX10 GX20 GP10 GP20 Paperless Recorder First Step Guide IM 04L51B01 02EN GX10 GX20 GP10 GP20 Paperless Recorder User s Manual IM 04L51B01 01EN GM unit GM10 GM90PS GM90MB with the GX90ExX installed m SD memory card Format the SD memory card using the SD card formatter distributed by the SD Association Other formats are not supported by the firmware upgrade m Data Acquisition System GM First Step Guide IM 04L55B01 02EN m Data Acquisition System GM User s Manual IM 04L55B01 01EN Notes Note 1 This document applies to the free expansion module firmware upgrade Note 2 If in factory maintenance or repair is ever required be sure to inform the factory that t
2. eparing the SD memory card for the upgrade 2 1 Download the upgrade file from our website and save it to your PC 2 2 Double click the file and unzip it to a folder of your choice 2 3 Save the unzipped file see table 1 in the root directory of the SD memory card Confirm that no other files having the same extension are saved on the SD memory card 2 4 Confirm the presence of the file in table 1 Table 1 Firmware used for upgrades Files Folder Name File ex_r10201 iom 21 Notes Expansion Module Firmware Upgrade Procedure Note 1 If installing the expansion module in the GX GP GM main unit you must set the expansion module to Master operation turn dip switch 8 ON 3 Upgrading the expansion module To upgrade the expansion module perform a Batch update or Individual update The Batch update allows you to upgrade the GX GP main unit and the I O modules GX90XA GX90XD GX90YD GX90WD connected to the GM unit at the same time If upgrading the I O modules at the same time the I O module upgrade files must be saved on the upgrade SD memory card 3 1 GX GP main unit m Switch to Update mode 3 1 1 3 1 2 3 1 3 3 1 4 3 1 5 Insert the SD card prepared in step 2 into the SD card slot Check that recording is stopped the START STOP key is unlit If recording is in progress press the START STOP key to stop recording Press the MENU key on the main unit and then tap Browse gt Initial
3. he unit has been upgraded 11 Expansion Module Firmware Upgrade Procedure Upgrade Procedure The expansion module firmware upgrade is performed by using main unit screen operations in the case of the GX GP main unit or through a web application in the case of the GM Note that if the GX GP main unit version is earlier than R2 01 01 you must upgrade to R2 01 01 or later before proceeding with expansion module upgrade described below 1 Checking the version of the expansion module Follow the steps below to check the version of the expansion module before performing the upgrade 1 1 GX GP main unit 1 1 1 1 1 2 1 1 3 1 2 GM 1 2 1 1 2 2 1 2 3 On the main unit press the MENU key Tap Browse gt System information gt Module information to display the module information screen Tap the desired module to view its details Look for the version under Version information If the version matches the post upgrade version you do not need to perform the upgrade Connect to the GM web application from a PC web browser For instructions on viewing or setting the GM s IP address see Configuring the GM via Ethernet Communication in the Data Acquisition System GM First Step Guide IM 04L55B01 02EN On the Data tab click System information to display the structure of connected modules Look under Version If the version matches the post upgrade version you do not need to perform the upgrade 2 Pr
4. ion return to step 3 and retry the upgrade 5l Expansion Module Firmware Upgrade Procedure Yokogawa Electric Corporation ns cs jp yokogawa com www yokogawa com ns Issued in December 2014 copyright Yokogawa Electric Corporation 6l
5. ize calibration gt Menu Update Tap Execute A confirmation screen appears for switching to Update mode Tap OK The unit restarts and switches to Update mode m Update 3 1 6 3 1 7 3 1 8 3 1 9 Tap Module gt Individual update Main unit or unit 1 6 gt I O Expansion module The current version and post update version of the selected module is shown For batch updates tap Module gt Batch update All modules The post update version of the selected module is shown Tap Execute A confirmation screen appears Tap OK The firmware of the selected module is updated Do not perform any operations during updating and especially do not turn the power OFF To return to Normal mode tap Exit If a confirmation screen appears tap Yes The unit restarts and switches to Normal mode For details on Batch Individual updating see section 5 1 6 Updating the Firmware Release number 2 and later in the GX10 GX20 GP10 GP20 Paperless Recorder User s Manual IM 04L51B01 01EN 3 Expansion Module Firmware Upgrade Procedure 3 2 GM m Switch to Update mode 3 2 1 Insert the SD card prepared in step 2 into the SD card slot 3 2 2 Confirm that recording is in progress that the REC status LED is lit If recording is in progress stop recording by holding down the STOP key for at least 3 seconds 3 2 3 Connect to the GM web application from a PC web browser 3 2 4 On the Calib tab click Update A confirmatio
6. n screen appears for switching to Update mode 3 2 5 Click the Next button The Mode Switching dialog box appears 3 2 6 Click OK The unit restarts and switches to Update mode m Update 3 2 7 Inthe Contents area under Update Mode select Module 3 2 8 Click the expansion module to update GX90EX If performing a batch update click All modules 3 2 9 Click the Next button The Update dialog box appears The current version and post update version are shown If performing a batch update the post update version of the selected module is shown 3 2 10 Click Update The firmware of the expansion module is updated When finished the Update dialog box appears Do not perform any operations during updating and especially do not turn the power OFF 3 2 11 Click OK 3 2 12 To return to Normal mode click the End button If the Mode Switching dialog box appears click OK The unit restarts and switches to Normal mode Before performing a batch update first update the GM unit expansion modules to R1 02 01 or later For details on Batch Individual updating see section 5 1 5 Updating the Firmware in the Data Acquisition System GM User s Manual IM 04L55B01 01EN 4 Expansion Module Firmware Upgrade Procedure Checking the version of the expansion module Check whether the upgrade was successful 4 1 Follow the instructions in step 1 to confirm that the version is the latest 4 2 If not the latest vers