ADEMCO 6162 / 6162V Custom Alpha Keypad
Contents
1. INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED FOR WARRANTY INFORMATION AND LIMITATIONS OF THE ENTIRE ALARM SYSTEM 2 Corporate Center Drive Suite 100 Hone ell P O Box 9040 Melville NY 11747 YW Copyright 2013 Honeywell International Inc www honeywell com security 800 11507V1 7 13 Rev A
2. of the message is adjustable e Refer to the procedures below when using the Message Center functions To record a message Press 0 keys The MESSAGE ICON 4 will light indicating recording is in progress Note A message cannot be recorded during the Exit Delay period To end recording Press key the keypad will ding twice to indicate recording is ended The MESSAGE ICON will flash indicating a message is waiting to be played To play a message Press 0 3 gt m The recorded message plays and the MESSAGE ICON turns off The recorded message will remain in memory until a new message is recorded To adjust the volume Press 0 16 2 1 to adjust the volume one level Volume levels are Low Off On High and Medium With each level adjustment the keypad announces CHECK at Low Medium and High volumes ON or OFF to verify the current setting Note Adjusting the message volume also adjusts status volume The volume cannot be adjusted while playing a message Voice Mode When Voice mode is enabled the keypad announces basic system arming status upon arming or disarming e g Disarmed Ready to Arm Armed Away To enable the Voice mode Adjust the keypad volume to On or Check at the desired volume To disable the Voice mode Adjust the keypad volume to Off Note See To Adjust the volume in the Message Center se
3. Honeywell ADEMCO 6162 6162V Custom Alpha Keypad User Guide Addressable Custom Alpha Keypads for use with Honeywell Control Panels 4 Line Alpha Display Custom Zone Designators Se l 4 S amp S System ARMED Co System NOT ARMED A K READY to Arm c NOT READY to Arm E Cae Cer E CO C C G o gt 6162V Message Indicators Lye P M0 Recording Message 1 81 20 ON Q181 OYdADHAZ9 19 2919 Message Recorded Z No message See the keypad s User Guide for details C Ce cus Honeywell i 6162V Keys 6162V Microphone Programmable Arming Keys PEN Function Keys a The Function Keys can be be programmed for special functions or panic alarm activations See the Function Keys section and check with the system installer for more information UL NOTE The User Code Quick Programming and Fire related features were not evaluated by UL The Panic feature is not for use for UL 609 and ULC S303 applications 6162V VOICE CONTROL KEYS VOLUME ADJUST PLAY STOP RECORD Refer to the 6162V Keypad Voice Features section for details using these VOICE KEY keys FUNCTION RECORD SETTINGS KEY Displays Settings Menu 1 Set Time Date 2 View Event Log 3 Reboot Keypad Press eemnes 4 Set User Code The
4. User Code option Enter the Master User Code at the Enter Your Code prompt and press to see a user option screen Add a User Press to select Add a User option e At Enter User No screen enter a unique two digit number and press G e At the New User Code prompt enter a new four digit user code and press _ Note Four digit user codes options 0000 9999 The keypad will confirm the User setting and exit the Settings mode Confirmation Meaning Short ding User created successfully Long ding Error that user number already has a user code assigned No sound User not created try again If necessary delete the user and try again Delete a User Press 2 to select Delete a User option e At Enter User No prompt enter the desired two digit number and press The keypad will ding to confirm the User deletion and exit the Settings mode Assign Attributes Press Gra to select Assign Attr option e At Enter User No screen enter the desired two digit user number and press The Assign Attributes menu appears 1 Authority Level 2 Access Group 3 User Partition 4 RF User Number 5 Pager On or Off Refer to the system User Guide for assigning the appropriate user settings in the Assign Attributes Menu SINGLE BUTTON ARMING If desired the Arming Keys can be set for Single Button Arming by following prompts to stor
5. ction Voice Chime Each keypad can be set to announce faulted opened entry exit or perimeter zones when the control panel s Chime mode is on To enable the Voice Chime mode Adjust the keypad volume to On or Check at the desired volume and turn on the keypad Chime mode Code 9 come When enabled Voice Chime provides a voice status annunciation chime and display when any entry exit or perimeter zone is faulted When the Voice mode is disabled but Chime mode is enabled the sounder will still provide Chime annunciations when zones are faulted Voice Status The keypad can be set to announce current system status and display any system and or zone faults if they exist To enable Voice Status make sure Voice Chime mode is on see previous section then e To Announce Status Press 0 _ key once The respective system status is announced e g Disarmed Ready to Arm or Disarmed Not Ready to Arm Note Status cannot be announced during the Exit Delay period e To Announce Faults Press 0 _ and the key a second time within 10 seconds of the first press Up to 3 faulted zones are announced with their zone descriptors if programmed If zone descriptors are not programmed the respective zone numbers are announced FUNCTION KEYS The Function keys may be programmed by the installer Aor and for special functions or alarm activations Key pairs may also be p
6. e a valid user code in the keypad See the system User Guide for details on programming user codes When Single Button Arming is disabled a valid user code is required to arm the system with the Arming keys Enabling Single Button Arming 1 Press and hold down the and Grm keys at the same time for 3 seconds The screen displays the keypad s address Press to move to the USER CODE entry screen Enter a valid four digit user code between 0000 9999 and press to save and exit Recommended Set a dedicated user code for this feature The user code must be entered for each keypad in the system where Single Button Arming is desired EE Disabling Single Button Arming 1 Press and hold down the and 3 gt m keys at the same time for 3 seconds The screen displays the keypad s address 2 Press to move to the USER CODE entry screen 3 Enter 0 and then press to exit COMMERCIAL STAY MODES For commercial controls if Stay Mode 2 is programmed refer to the control s manuals and the table below for Stay mode arming Cw Jat Stay Mode 1 sw 2 Stay Mode 2 Stay Mode 3 both Stay 1 and Stay 2 modes 6162V KEYPAD VOICE FEATURES Message Center The keypads feature a voice message center that lets you record and playback one message e The message can be up to 2 5 minutes long e The message remains in the keypad s memory until a new message is recorded e The volume control
7. menu based user code 1 Add a User programming feature is only 2 Delete a User available with certain systems 3 Assign Attr Check with the system Menu options details below installer for details on features of your system Note For Commercial controls some of the steps are different than described in the following section Refer to the system User Guide for details on setting these options SETTINGS KEY FUNCTION Set Time Date 1 Press sermes to enter Settings mode and press to select Set Time Date option Enter the Master User Code at the Enter Your Code prompt and press The Time Date screen appears Press to edit the time and date e Use the number keys to change the time and date shown PM 0 0 AM The navigation keys to move the cursor G forward o back e When done editing press to save and exit View Event Log i 2 3 4 Press to enter Settings mode and press e to select the View Event Log option Enter the Master User Code at the Enter Your Code prompt and press Press to move forward or e to move backward through events To exit press any key except and e the keys Reboot Keypad 1 Press sermnes to enter Settings mode and press 3 gt m to Reboot the keypad The keypad beeps and the keypad LEDs flash for several seconds Set User Codes 1 Press to enter Settings mode and press to select Set
8. r is encouraged to try to correct the interference by one or more of the following measures If using an indoor antenna have a quality outdoor antenna installed e Reorient the receiving antenna until interference is reduced or eliminated Move the radio or television receiver away from the receiver control Move the antenna leads away from any wire runs to the receiver control e Plug the receiver control into a different outlet so that it and the radio or television receiver are on different branch circuits e Consult the dealer or an experienced radio TV technician for help INDUSTRY CANADA CLASS B STATEMENT This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme a la norme NMB 003 du Canada FCC IC STATEMENT This device complies with Part 15 of the FCC rules and RSS210 of Industry Canada Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Cet appareil est conforme a la partie 15 des r gles de la FCC amp de RSS 210 des Industries Canada Son fonctionnement est soumis aux conditions suivantes 1 Cet appareil ne doit pas causer d interf rences nuisibles 2 Cet appareil doit accepter toute interf rence re ue y compris les interf rences causant une r ception ind sirable REFER TO
9. rogrammed for alarm activations Bor and te To activate the Function keys press and hold the key c d for at least 2 seconds key pairs are activated or G gt an G immediately D Check with the system installer for more information FEDERAL COMMUNICATIONS COMMISSION FCC STATEMENTS The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User s Manual Unauthorized changes or modifications could void the user s authority to operate the equipment Class B digital device Statement This equipment has been tested to FCC requirements and has been found acceptable for use The FCC requires the following statement for your information This equipment generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television reception It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules which are designed to provide reasonable protection against such interference in a residential installation However there is no guarantee that interference will not occur ina particular installation If this equipment does cause interference to radio or television reception which can be determined by turning the equipment off and on the use
Download Pdf Manuals
Related Search
Related Contents
Sony Xperia E4g 8GB 4G White Benutzerhandbuch AGRETO Waagenbausatz User Manual A2 - sounddevices.dk PULSAR Sony VAIO VPCCB23FX Fujifilm Pivi MP-300 User's Manual K330a Guía del usuario ANEXO DE ESPECIFICACIONES SERVICE BULLETIN Copyright © All rights reserved.
Failed to retrieve file