Home

QUICK START GUIDE

image

Contents

1. 0 Default Gateway 192 168 0 1 Preferred DNS 192 168 0 1 3 Access Web User Interface Open a web browser and enter the following in the address bar http 192 168 0 1 10000 LOGIN INSTRUCTIONS e User Name admin lowercase letters e Password last six digits of the unit s serial number Upon successfully logging in the web UI will launch Note For security purposes it is recommended that the admin pass word be changed according to your internal policies To change password go to Admin gt Access Settings Web UI e redipn Status Admin Network Services Automation System Information Device Model Number RAM 6021 Device Serial Number 6621 1549 xxxxx Installed Firmware Version SN version 4 xx Current System Uptime 2D 12H 21M 46S Physical Interface Status Interface Name Connection State IP Address Link Status ethO WAN Up 192 168 0 1 Down eth1 LAN Up 192 168 1 1 Down usb Up 192 168 111 1 Up Last Refresh ran A few seconds ago 2014 Red Lion Controls All Rights Reserved 1 You are now connected to the web interface If you should see anything other than the screen shown above please refer to the RAM 6021 User Manual located on our website www redlion net For more information to set up Modbus features please refer to the RAM 6021 User Manual HARDWARE STATUS LEDs LED State Description Power ON Power is applied to the router ON Excellent signal strength Signal FLASH
2. meet the following specifications e Dual Band 800 amp 1900 MHZ e Nominal 50 ohm impedance e Voltage Standing Wave Ratio VSWR less than 2 5 1 There are 4 methods to provide power to the router e 4 pin Molex connector available on RAM 6x00 e 4 pin screw terminal available on RAM 6xx1 EB e Side mounted 2 5mm barrel connector all models e Power over Ethernet available on RAM 6x01EB The modem requires a power source between 8 and 30 VDC to operate LABEL DESCRIPTION GND Ground PWR Power 8 to 30 VDC 12 or 24 VDC nominal IN Digital and analog input OUT Digital output 6 Please allow 2 4 minutes for the unit to recognize the cellular data card and connect to the cellular network When this has occured the Signal Strength LEDs should light up see table on back If sig nal strength is not lit or flashes slowly please refer to the User Manual at www redlion net ACCESSING THE WEB USER INTERFACE 1 Connect PC to the RAM 6000 Router Connect a CAT 5 Ethernet cable between the local PC and the unit s Ethernet port Verify that the green LED is lit 2 Setup PC IP Address For assistance with configuring your PC see the appropri ate Microsoft support webpage listed at http support microsoft com PC to Ethernet Interfaces Select Use the following IP address and fill in the blank fields with the information below Ethernet 0 IP Address 192 168 0 2 Subnet Mask 255 255 255
3. AY DEGRADE THE SEAL ING PROPERTIES OF MATERIALS USED IN THE RELAYS AVERTISSEMENTS POUR INSTALLATION ET ENDROITS DANGEREUX Cet quipement est adapt pour une utilisation en Classe I Division 2 Groupes A B C et D pour endroits dangereux ou endroits non dan gereux seulement Tout c blage lectrique entr e et sortie I O doi vent tre en conformit avec Classe Division 2 m thodes de cablage et conform ment a l autorit comp tente AVERTISSEMENT RISQUE D AVERTISSEMENT NE D BRANCHEZ PAS L QUIPEMENT PENDANT QUE LE CIRCUIT EST DIRECT OU MOINS QUE L ENVIRONNEMENT SOIT CONNU POUR TRE NON DANGEREUX AVERTISSEMENT RISQUE D EXPLOSION LA SUBSTITUTION DE TOUT COMPOSANT PEUT NUIRE LA CONFORMIT DE CLASSE I DIVISION 2 AVERTISSEMENT RISQUE D EXPLOSION LES BATTERIES DOIVENT SEULEMENT TRE REMPLAC ES DANS UNE ZONE RECONNUE COMME TANT NON DANGEREUSE AVERTISSEMENT L EXPOSITION CERTAINS PRODUITS CHIMIQUES PEUT D GRADER LES PROPRI T S D TANCH IT DES MAT RIAUX UTIL IS S DANS LES RELAIS TANCHE P RIPH RIQUE 2014 Red Lion Controls All Rights Reserved 2
4. Flashes faster as signal is stonger OFF Very weak or no signal less than 100dBm ON Wireless link established but no data activity WAN FLASH Data transmitted received on wireless network ON Link established with serial device but no data activity RS232 FLASH Data transmitted received with attached serial device ON Link established with Ethernet device Ethernet FLASH Data transmitted received RED LION CONTROLS TECHNICAL SUPPORT If you have followed all of the instructions up to this point are satisfied that you are not having an authentication problem and your unit is still not communicating then it it is time to contact Red Lion Technical Support at support redlion net or 1 877 432 9908 CONNECT MONITOR CONTROL Quick Start Guide INSTALLATION AND HAZARDOUS AREA WARNINGS Suitable for use in Class Division 2 Groups A B C and D hazardous locations or non hazardous locations only All power input and output I O wiring must be in accordance with Class Division 2 wiring meth ods and in accordance with the authority having jurisdiction WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON HAZARDOUS WARNING EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I DIVISION 2 WARNING EXPLOSION HAZARD BATTERIES MUST ONLY BE CHANGED IN AN AREA KNOWN TO BE NON HAZARDOUS WARNING EXPOSURE TO SOME CHEMICALS M
5. red lon QUICK START GUIDE RAM 6000 Series Router GSM CDMA or HSPA with Modbus UNPACKING INSTRUCTIONS 1 CONNECT MONITOR CONTROL Unpack the Red Lion unit and verify the following components are enclosed for the RAM 6000 Router RAM 6xxx AC adaptre with either barrel connec tor AC or Molex MX or 15ft Molex cable DC can be ordered in a kit ie RAM 6600 xx AC or MX or ordered spearately RAM 6400 not avail able ar eee naza E a RAM 6x01 4 pin plug with screw terminals to connect to an external DC power source Available wth AC adaper with barrel connector AC RAM 6x21 4 pin plug with screw terminals to connect to an external DC power source Available with AC adapter with barrel connector AC Antennas sold separately Contact your cellular provider carrier and request a data account For CDMA models RAM 66xx give the ESN number of the router to the carrier to activate the data account For GSM and HSPA models RAM 64xx amp SN 68xx the carrier should provide you with a SIM card to insert into the router along with the APN username amp password for data connectivity Insert the SIM card GSM and HSPA models only e Locate the SIM slot on the right side of the unit e Insert the card with its cut side facing forward and on the left e Using the tip of a pen push it in until it clicks An antenna with an SMA connector should be connected to the router This antenna should