Home
        user manual - Heatrae Sadia
         Contents
1.                   1 Low  trickle   2 Middle  3 Boost     3 1  Remote speed control  hard wired   supplied separately     The speed selector switch does not require  any maintenance    Manual speed selector    You are able to select a speed by hand      gt  itho   11    3 2  Remote speed control  wireless   supplied separately     The ITHO RFT remote controller has been  equipped with a long life battery type  VARTA CR2032 Li Mn 3V  Under normal  circumstances the battery life time will be  approximately 10 years     RFT wireless remote controller   You are able to select a speed by pushing  button                    63  Low  trickle speed     Middle    Boost     X Timer function           itho   12    Every time you push the timer function 3 3  Frost protection  button  the unit will be switched to boost  speed for 10 20 30 minutes  After this time     the set speed returns automatically to the  Note     former speed     In case of very low outside temperatures    In case the former speed was    Boost    then    for more than 24 hours  the fan motor will    the speed returns to low     automatically switch off for several minutes to    avoid a frozen heat exchanger  It will restart    itself when the temperature has risen          gt  itho   13    4  Commissioning    The installer is responsible for commis   sioning the required air volumes rates for  every room  in compliance with the current  local regulations  for England and Wales  this is the Domestic Ventilation Complia
2.       itho   4          1 1 Configuration    The Advance has been developed for  apartments and small houses with  approximately 100 125 m  h balanced  exhaust and supply air volumes  It can be  fitted as a wall  floor  or ceiling mounted  unit for example in the space of a kitchen  cupboard    Dimensions 597 mm width x 280 mm depth  x 760 mm height     Note     Read this manual carefully     Failure to follow these instructions may    cause an adverse effect on your health     Leave these instructions in the unit           gt  itho   5    1 2  Itho conditions    Itho does not accept any liability for  damage caused by non observance of the  installation instructions  Service activities  must exclusively be carried out by Itho or  by suitably qualified competent persons  using original Itho parts                 4    itho   6    13 Serial number  date of commissioning and scheduled service intervals    Serial number    Date of commissioning    Installers company name    Service call telephone number    Next service   filter replacement interval     1  date                      2  date       3  date       4  date       5  date       6  date  7  date  8  date  9  date  10  date                      gt  itho   7    2  Safety    2 1  General    A    Always disconnect the electric power cord    from the mains  before you remove the    motor part     e Do not use this appliance for  functions other than those described  in this booklet        Never touch the appliance with wet or  
3. Itho  Advance           lt   itho    Climate for life    Contents    1     2     Introduction   1 1  Configuration   1 2  Itho conditions   1 3  Serial number  date of  commissioning and scheduled  service intervals    Safety  2 1  General  2 2  Liability of the user      Description controller functions    nano DA    so 00 009    10    3 1  Remote speed control hard wired 10    3 2  Remote speed control wireless    3 3  Frost protection    11  13    4  Commissioning    5     7     4 1  Manual potentiometers low   and boost speed  4 2  Middle speed    Trouble shooting  5 1  FAQ s    Maintenance  6 1  Cleaning  6 2  Filter replacement    Guarantee    Subject to changes without notice     No rights can be derived from this user manual     15  15    18  18  18    20     lt  itho   3    1  Introduction    Indoor air quality and energy efficiency  are very important considerations in  dwellings today  The Itho Advance Heat  Recovery Ventilation Unit has been  developed to meet these demands and  offers controlled and better ventilation for  a healthy and comfortable indoor climate  in full compliance with current building  regulations  while regaining the heat to an  efficiency of up to 90      For the home owner or occupant   This document explains the working  principle of the ventilation system and how  to operate and maintain this unit     Never switch off the ventilation  by  disconnecting the power cord from  the mains supply     Except for service and maintenance  intervals
4. damp hands  or when barefoot    Do not store inflammable products in  the neighbourhood of the unit    The unit is only suitable for 230 VAC   50Hz electric mains    Never modify the fan or electronics by  yourself    Never plug in the power cord if the  motor part is not placed into the unit     itho   8    4    2 2  Liability of the occupant    user Note     g   e The grilles should always be placed back  e Cleaning or replacement of the filters   NN    a      in their original location and position   in the Advance unit at the correct      g If the grilles are changed or placed  time  See chapter 6 2 Maintenance    D SA        in a wrong position  the ventilation  e Cleaning the grilles in the rooms at    volumes will no longer be correct and    regular intervals     A    Replace the filters on time    the ventilation system might not work  properly   Always disconnect the electric    power cord when carrying out any    Filter pollution could damage your health     maintenance         lt  lt  itho   9    3  Description controller  functions    Your Advance heat recovery unit has been You are able to switch the unit 3 speed   equipped with a high performance heat e Low  continuous     recovery exchanger  so there is no need to e Middle  extra comfort   if there are  reduce the air volumes in order to thermal more persons in the dwelling    energy  However  reducing noise and saving e Boost  cooking and bathing      electricity is also an important issue       gt  itho   10 
5. depending on       A  Remove the plastic cover      lt   itho   18                         B  Remove the filter from the unit  C  Clean the filter with a vacuum cleaner       gt  itho   19    7  Guarantee    Warranty  The Advance warranty is valid for 3 years  after the installation date     Disclaimer   e This warranty does not apply to    e Disassembly and assembly costs    e Faults which are caused by incorrect  treatment  negligence or accident    e Faults that have been caused by  repairs by third parties without  authorisation from ITHO UK Ltd     If the appliance does not function correctly  or a fault occurs  please contact your  installer or service technician immediately   Ensure that only genuine spares are used  for repairs       gt  itho   20    Notes                                 Notes                                 Notes                                 Itho UK Ltd  Unit 52 Basepoint Business Park    Metcalf Way  Crawley  West Sussex  RH11 7XX       T  44  0  845 250 8090  F  44  0  845 250 8091  E info itho co uk    www itho co uk          
6. n boost speed at cooking time   e The filters are polluted  clean or  replace both filters   e The grilles are dirty  clean all  grilles     Il  Near the unit    e Condensate trap below the unit is  empty  fill it up with water    e The flexible condensate hose is not  completely in the condensate trap   push it in deeper    Ill  Near the supply air grilles    e The unpleasant air comes from  outside  not a ventilation fault but  to be sure  check and clean supply  air filter       gt  itho   16    e  Too much condensation in the bathroom  g  No speed change after pushing the button    e Too low exhaust air volume  switch on the RFT remote controller   on boost speed while showering or e Replace the battery in the remote  bathing  Check and clean filters controller  type CR2032 Li Mn    and grille  h  If the problem persists  report the details  f  Water leakage near the unit  to your installer or service technician     e Condensate trap is clogged  clean  it    e Condensate flexible hose is clogged  or twisted  clean it and replace it  into the trap     itho   17    4    6  Maintenance    6A  Cleaning the Advance unit environmental pollution from industry or  outside covers traffic and also the activities in the house        Keep the unit surface free from dust     6 2  Filter replacement    For the user  maintenance is limited to  cleaning and replacing the filters   These will need to checked annually and  either cleaned or replaced           This may differ per situation 
7. nce  Guide      4 1  Manual potentiometers  low  and boost speed    A    Do not change the manual potentiometers    on the Advance unit  it has been set by the  installer in accordance to the required air    volumes        4 2  Middle speed    Middle speed has been set in the controllers  software by the manufacturer and cannot be  changed      lt  itho   14    5  Trouble shooting    5 1  FAQ s e The condensate trap below the unit  has a too low water level  fill it up    a  The fan has been switched off with water   unexpectedly  e The flexible condensate hose is not  e Mains voltage failure  check the completely in the condensate trap   Fuse Spur or in the distribution push it deeper   board cabinet meter cupboard  Il  Rattling noise coming out the unit   e Plug in the power cord  e Fan motor fault  please contact your  e Frost protection active  wait for installer or service technician   120 minutes and the fan will be III  Swishing sound coming out of the  switched on  grilles   b  The unit makes a lot of noise  e There is too much air pressure drop     Gurgling noise coming out the unit  in the duct and grilles  clean both    filters in the Advance unit and the      gt  itho   15    grilles in the rooms and check if the  grilles are in their original position   c    want to switch off the unit at night   e Not possible  you also need fresh  air during the night   d  Unpleasant smell      I smell the cooking in the whole  house   e Air extract rates are too low  switch  o
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Untitled - Caldera  para automação de 2, 4, 6 e 8 feixes barreira óptica  Cahier 3 - Restode  Soporte BKT-LA5 de Christie Vive Audio      Copyright © All rights reserved. 
   Failed to retrieve file