1. on To turn off the UPS please press power button for about 3 seconds OPTA www opti ups com Front amp Rear Panels No Load Shutdown Function F As a battery saving feature the UPS will automatically turn off if none ly 4 of the connected equipment is operating while the UPS is in back up mode Once normal utility power returns the unit will re start automatically You can disable the No Load Shutdown function by pressing the power button of your switched off UPS until you hear two beeps Front panel LED UPS status indicator When the LED is continuously lit and the buzzer is silent the UPS is in normal mode and providing power to your equipment The UPS will continue to filter electrical noise and provide surge protection When the LED blinks every 2 seconds in time with the beeping sound the UPS is providing power from its battery Battery Mode 1 1 Power Button 1 2 RS 232 Port 1 3 Phone LAN Jack 1 4 AC Input 1 5 UPS Outlets 1 6 AC Fuse TS B models only DO NOT PLUG LASER PRINTERS INTO THE UPS BECAUSE THEY TYPICALLY DRAW TOO MUCH POWER When the LED is flashing rapidly and the beeping sound is continuous it indicates that the UPS is overloaded Battery replacement procedure Note Follow this procedure for safe replacement of the battery However small sparks may occur during the process This is normal Fuse Holder i i Turn off the UPS Remove all plugs Remove the fo
2. supplies or parts not meeting our specifications g Normal wear and tear h Any other cause which does not relate to a product defect 3 Removal installation and set up service charges Limitation of implied warranties There are no warranties expressed or implied which extend beyond the description contained herein including the implied warranty of merchantability and fitness for a particular purpose Exclusion of damages Our liability is limited to the cost of repair or replacement of the product We shall not be liable for 1 Damage to other property caused by any defects in the product damages based upon inconvenience loss of use of the product loss of time loss of profits loss of business opportunity loss of goodwill loss of data loss of software costs of substitute equipment interference with business relationships claims by third parties or other commercial loss even if advised of the possibility of such damages 2 Any other damages whether incidental consequential or otherwise 3 Any claim against the customer by any other party Input voltage too high or Checkin voite too low PCB failure Call for service Recharge the battery for 6 hours If the problem is still present replace the battery PCB failure Call for service Battery is not fully Back up time too short charged or defective beeping Contact Information USA Australia Taiwan OPTI UPS Corp OPTI Australia Pty Ltd OPTI Internationa
3. This UPS is intended for indoor use only its internal components are not Connecting your equipment to the UPS For all UPS models except the version with IEC outlets connect the power cord s of your computer equipment to the output receptacle s of the UPS sealed from the environment Please install it in a protected environment away from excessive heat or excessive moisture For UPS with IEC outlets as shown in the illustration use your computer power cord to connect UPS to the wall socket Use the power cord supplied with the UPS to connect your PC to one of UPS outlets Thunder Shield User s Manual Charging the UPS first The battery is fully charged at the factory However it is recommended to charge the battery at least 8 eight hours before using the UPS since energy loss may have occurred during shipping or long duration storage To recharge the battery simply leave the UPS plugged into an AC outlet Plug the PC input to the UPS To the wall outlet Move original computer power cord to the UPS input Turn on the UPS To turn UPS on please press the power button for 3 seconds Pressing the power button shortly under normal mode will enable the self test function The silence function can be enabled disabled by shortly pressing the power button in backup mode In addition the power button can be used as the master on off switch for your equipment by leaving your equipment connected to UPS and switched
4. l Corp Tel 1 909 869 5700 Tel 61 3 9545 5322 Tel 886 2 2246 7272 Toll Free 888 OPTI UPS Toll Free Toll Free 0800 029898 AU 1800 678 428 NZ 088 OPTI UPS info opti ups com au http www opti ups com au info opti ups com tw http www opti ups com tw info opti ups com http www opti ups com Europe United Kingdom OPTI UPS Europe OPTI UK Lindenstrasse 12a DDI 01489 581386 81545 Munchen Office 01489 583708 Tel 49 0 89 31 609 413 Fax 49 0 89 31 609 289
5. product with a like product How long the warranty is effective For accurate warranty period and conditions please contact the local branch offices or your dealers Who the warranty protects This warranty is valid only for the first consumer purchaser What the warranty does not cover 1 Any product on which the serial number has been defaced modified or removed 2 Damage deterioration or malfunction resulting from a Accident misuse neglect fire water or other acts of nature unauthorized product modification or failure to follow instructions supplied with the product b Repair or attempted repair by anyone not authorized by OPTI UPS c The fault is the result of accidental damage or damage in transit or transportation including but not limited to liquid spillage mode d Removal or installation of the product Troubleshooting Possible Cause Press the power switch for more than second until the UPS turns on Power switch not pressed long enough Recharge the battery for 6 hours by leaving the UPS plugged in and the load disconnected from the UPS Battery voltage is less UPS can t turn on than 10V LED does not light Load is less than 20W at battery mode Disable No Load Shutdown Function Call for service PCB failure Input power cord is loose Plug in the power cord firmly UPS always at battery Busted input fuse Replace the fuse e Causes external to the product f Use of
6. ur screws from the side slots Gently remove the top cover Disconnect the two wires connecting the battery to the UPS and pull out the battery Push the new battery into place Connect the wires to the new battery making sure that the red wire is connected to the red battery terminal and the black wire to the black battery terminal Mount the cover and replace the screws Follow the UPS turn on procedure Use a slotted screwdriver to take out the fuse holder Take out the busted fuse from the fuse holder Use the screwdriver to push out the spare fuse from the holder Put the spare fuse in the holder Push the fuse holder back into the AC input socket Follow the UPS turn on procedure Specifications Thunder Shield 400 240W Model Maximum Capacity Thunder Shield 500 B Thunder Shield 650 B Thunder Shield 1000 B 300W 360W 480W Topology On battery Output Waveform Simulated Sine Wave Input Voltage Range 110 120V or 220 230 240V 25 Input Frequency SOHz 60Hz Auto Sensing Communication Port Operating Temperature Unit Dimensions L XW gt H mm 260x97x135 320x97x135 4 2 6 0 6 3 6 2 6 5 TS B models only 6 3 6 7 LIMITED WARRANTY What the warranty covers We guarantee this product to be free from defects in material and workmanship during the warranty period If a product proves to be defective in material or workmanship during the warranty period we will at our sole option repair or replace the