Home

Oblica Bathysca Focus Hublot

image

Contents

1. This appliance does comply with the requirements of AS NZS 4013 1999 for the configuration tested PAGE 14 6 INSTALLATION CLEARANCE TEST TEST REPORT NO 30A 13 0024 TRP 349705 0 TESTING LABORATORY MANUFACTURER MODEL WORK REQUESTED ISSUE DATE INVESTIGATING OFFICERS CONCLUSION OBLICA BATHYSCAFOCUS HUBLOT INSTALLATION AND USER MANUAL VIPAC Engineers and Scientists FOCUS Bathysca Porthole Assessment of appliance in one configuration to AS NZS 2918 2001 Appendix B with a full length flue kit 09 07 2014 Christain Schmidt Rebecca Searcy This appliance does comply with the requirements of AS NZS 2918 2001 Appendix B for the configuration tested PAGE 15
2. plasterboard 1000mm minimum clearance is required on all sides when the BathyscaFocus Hublot can rotate 360 Combustible FFA d e qnsnquio FULLY ROTATING 730mm minimum clearance trom the back and 1000mm from the side is required if the rotation of the BathyscaFocus Hublot is locked at 90 away from the wall Locking the BathyscaFocus Hublot so that the opening is fixed is an option available on purchase Combustible Z Z 2 750 ejq snquio 1000 lt gt 2 Clearances may be reduced with the application of heat shielding to walls in accordance to the Australian Building Code For information on heat shielding please contact our office on 03 9416 0400 or email infoldoblica com au PAGE 4 3 INSTALLATION 3 1 Installing the suspension bracket The bracket must be structurally secured within the roof as shown in the diagram below The largest cylinder must project down from the ceiling by at least 150mm BCA requirement unless the ceiling is made from a non combustible material such as concrete You must leave a 259mm clearance gap between the bracket and the ceiling This gap will be covered by the ceiling Flange e 2mm ventilation gap between the plasterboard and the ceiling flange e 49mm minimum clearance from the triple skin flue to any combustible material within the roof space e 40mm minimum overlap of the stainless steel H flue into the connector TYPICAL FLAT R
3. CONTINUED 3 3 Installing the internal flue Position the single skin flue inside the suspension bracket and tighten the grab screws Ensure that the flue is perfectly vertical and the grab screws are tight Grab Screw OBLICA BATHYSCAFOCUS HUBLOT INSTALLATION AND USER MANUAL PAGE 8 3 INSTALLATION CONTINUED OBLICA BATHYSCAFOCUS HUBLOT INSTALLATION AND USER MANUAL PAGE 9 3 INSTALLATION CONTINUED low part of the black steel flue parte inferiore del condotto in acciaio nero Hauchrohrende aus schwarzem Stahl bas du conduit en acier noir O E s but es billes ball bearings EH cuscinetti a sfera U Axialkugellager O 20 int N A TF P rVVMh manchon de d part de fum es gt 21 int smoke outlet sleeve manicotto di uscita dei fumi Rauchabzugsmuffe 2 rondelles x washers im EET rondella Unterlegscheibe 19 21 40 CHE 21 int A O 20 int crou M12 nut M12 vc rc 0 13 27 dado M12 Mutter 12 mm pille d ka poupe de securite split pin copiglia di sicurezza Splint ee e Vi gt e 13 TT OBLICA BATHYSCAFOCUS HUBLOT INSTALLATION AND USER MANUAL PAGE 10 3 INSTALLATION CONTINUED 3 4 Protecting the floor Any combustible floor beneath a fireplace must have a floor protector that extends 300mm beyond the diameter of the firebox in all directions
4. f installed directly on combustible material the floor protector must be made of a minimum 6mm thick cement sheet Non combustible finishes can be applied to the floor protector tiles steel sheet light concrete etc the combustible floor is installed on concrete you can replace the combustible material with non combustible material laid directly onto the concrete FLOOR PROTECTOR LAID ON TIMBER FLOOR 300mm Insulative board 6mm non combustible finish Combustible floor eg timber me FLOOR PROTECTOR LAID ON JOIST Insulative board 6mm floor eg timber e non combustible finish Combustible 300mm gesch OBLICA BATHYSCAFOCUS HUBLOT INSTALLATION AND USER MANUAL PAGE 11 3 INSTALLATION CONTINUED FLOOR PROTECTOR LAID ON CONCRETE Combustible floor eg timber Non combustible finish eg tiles FIREBOX NS Floor protector non combustible finish Combustible floor eg timber OBLICA BATHYSCAFOCUS HUBLOT INSTALLATION AND USER MANUAL PAGE 12 4 OPERATION 4 1 What you should burn Untreated air dried hardwood Split logs with a humidity content of less than 20 4 2 Do not burn Trash Painted plastic e Coated or preservative treated wood Waste or black coal e Inflammable liquids Fire gels Moist wood with a residual humidity content of more than 20 this may cause soothing of the chimney IMPORTANT M
5. BATHYSCAFOCUS HUBLOT INSTALLATION AND USER MANUAL 1 TECHNICAL DATA 2 PRE INSTALLATION D 3 INSTALLATION J 4 OPERATION 13 9 EFFICIENCY AND EMISSIONS TEST 14 6 INSTALLATION CLEARANCE TEST 19 Keep for future ep OBLICA 200 Argyle st locus 1 TECHNICAL DATA WEIGHT AND DIMENSIONS Firebox diameter 700mm Firebox weight d i Flue diameter 219mm Flue weight 16Kg meter standard bracket weight 20Kg External flue kit Triple skin 200 250 300mm DETERMINED UNDER TEST CONDITIONS Nominal thermal output 17 8kW Efficiency 29 0 Jo FIREBOX 00 mm uu 006 OBLICA BATHYSCAFOCUS HUBLOT INSTALLATION AND USER MANUAL PAGE 2 2 PRE INSTALLATION Congratulations on your purchase of the BathyscaFocus Hublot This appliance should be installed and checked by a qualified professional Ensure you have read the operation guidelines thoroughly prior to first use For any questions or concerns please contact Oblica on 03 9416 0400 he installation process is outlined below Determine position of firebox and flue carefully observing the clearances described within this section Install the suspension bracket Install the external flue Install the internal flue and engage the firebox Ensure the floor has adequate protection CAUTION Using components or parts other than those provided by the manufacturer or modifying the specification of components m
6. OOF INSTALLATION CHINAMAN HAT Anti Down Draft device 4 TRIPLE SKIN FLUE 200 X 250 X 300 8 x 10 x 12 u RUBBER FLASHING Ke Insulative pad CROSS BAR SET IN BETWEEN RAFTERS E CEILING FLANGE lt SUSPENSION BRACKET CONNECTOR LOWER FLUE 219mm dia OBLICA BATHYSCAFOCUS HUBLOT INSTALLATION AND USER MANUAL PAGE 5 3 INSTALLATION CONTINUED PITCHED ROOF INSTALLATION CUSTOM MADE BRACKET Custom Length amp Anc OBLICA BATHYSCAFOCUS HUBLOT INSTALLATION AND USER MANUAL PAGE 6 3 INSTALLATION CONTINUED 3 2 Installing the external flue Place the connection piece inside the suspension bracket This will join the single skin flue below the bracket and the triple skin flue above the bracket which have different diameters 2 Ensure the triple skin flue is installed as per Australian standards see diagrams below PITCHED ROOF INSTALLATION The top of the flue must be 400mm higher than the highest point of the roof Alternatively there must be a minimum distance of 8 meters from any higher section of roof FLAT ROOF INSTALLATION LESS THAN 5 PITCH The top of the flue must be 1200mm above the roofline Alternatively there must be a minimum distance of meters any higher section of roof 28m gt 120 cm gt 120em gt 120em OBLICA BATHYSCAFOCUS HUBLOT INSTALLATION AND USER MANUAL PAGE 7 3 INSTALLATION
7. ay result in inferior or unsafe operation If such action is necessary consult the manufacturer in the first instance The appliance and flue system must be installed in accordance with AS NZS 2918 and the relevant building code or codes Any modification of the appliance that has not been approved in writing by the testing authority will be in breach of the approval granted for compliance with AS NZS 4013 Once the flue has been installed and approved by a professional installer the flue must not be modified in any way OBLICA BATHYSCAFOCUS HUBLOT INSTALLATION AND USER MANUAL PAGE 3 2 PRE INSTALLATION CONTINUED MINIMUM CLEARANCE INTERNAL 2 1 Clearance from non combustible surfaces eg masonry 3UUmm minimum clearance is required from fully non combustible surfaces Non Combustible FULLY ROTATING ala IsNnquio7 UON W 2 2 Clearance from glass 00mm minimum clearance is required from normal non combustible glass 3oUmm minimum clearance is required from toughened glass Glass frameless or aluminium frame 55 4 FULLY ROTATING Loupe uiniuluun e 40 Sse 9uJeJJ IMPORTANT Frames must also be considered limber window frames must be treated as combustible surfaces see 2 3 Aluminium frames can be treated as non combustible surfaces see 2 2 OBLICA BATHYSCAFOCUS HUBLOT INSTALLATION AND USER MANUAL 2 3 Clearance from combustible surfaces eg timber joist amp
8. isuse may lead to unhealthy and environmentally harmful emissions and will void any warranty or guarantee The maximum load capacity for the Bathyscafocus Hublot is 20kg of wood Burning only seasoned hardwood helps to protect the environment and lower emissions For details of a wood supplier in your area please call our office on 03 9416 0400 or email info doblica com au Do not use flammable liquids or aerosols to start or rekindle the fire Do not use flammable liquids or aerosols in the vicinity of the fireplace when operating Do not store fuel within prescribed installation clearance distances The use of some types of preservative treated woods as a fuel can be hazardous OBLICA BATHYSCAFOCUS HUBLOT INSTALLATION AND USER MANUAL PAGE 13 9 EFFICIENCY AND EMISSIONS TEST TEST REPORT NO 30A 13 0024 TRP 349704 0 TESTING LABORATORY MANUFACTURER MODEL WORK REQUESTED ISSUE DATE INVESTIGATING OFFICERS RESULTS CONCLUSION OBLICA BATHYSCAFOCUS HUBLOT INSTALLATION AND USER MANUAL VIPAC Engineers and Scientists FOCUS Bathysca Porthole Assessment of appliance to AS NZS 4012 1999 tor determination of Power Qutput and Efficiency and AS NZS 4013 1999 for Flue Gas Emission using hardwood fuel 09 07 2014 Christain Schmidt Rebecca Searcy The appliance particulate emission factor established in testing is 1 2g kg of dry wood within the maximum specification of 4 00 0 of dry wood

Download Pdf Manuals

image

Related Search

Related Contents

Samsung SGH-C520 manual de utilizador  Philips SWA3302W 6 ft Fiber optic audio cable  User`s Manual - Lakewood Automation  Manual Usuario KEY USB  L`EXTERMINATEUR PM - 57 POUDRE INSECTICIDE  LG 32LB5800 Energy Guide : Free Download, Borrow, and Streaming : Internet Archive  Zelmer Diana 887.5  User`s manual - VTech Communications  [U1.03.02] Méthodes Python d`accès aux objets Aster  Tripp Lite BCPERS300 User's Manual  