1. VEC251 Manual _051306 qxp 5 17 06 3 58 PM Page 6 TWO YEAR LIMITED WARRANTY PROGRAM This limited warranty program is the only one that applies to this product and it sets forth all the responsibilities of Vector Products Inc regarding this product There is no other warranty other than those described herein Any implied warranty of merchantability or fitness for a particular purpose on this product is limited in duration to the duration of this warranty This Vector Products Inc product is warranted to the original purchaser only to be free of defects in materials and workmanship for two years from the date of purchase without additional charge The warranty does not extend to subsequent purchasers or users Manufacturer will not be responsible for any amount of damage in excess a the retail purchase price of the product under any circumstances Incidental and consequential damages are specifically excluded from coverage under this warranty This product is not intended for commercial use This warranty does not apply to damage to units from misuse or incorrect installation connection Misuse includes wiring or connecting to improper polarity power sources RETURN REPAIR POLICY Defective products may be returned to manufacturer Any defective product that is returned to manufacturer within 30 days 1 the date of purchase will be replaced free of charge If such a product is returned more than 30 days but less than two years from the purch
2. VEC251 Manual _ 051306 qxp 5 17 06 3 58 PM Page 2 Control and Function Guide NOZZLE HATCH COVER LIGHT ON OFF NOZZLES PUSHBUTTON TRIGGER o a LOCK come COMPRESSOR PRESSURE Art TRIGGER TIRE CHUCK LED WORK LIGHT 12 VOLT DC POWER PORT 120 VOLT AC CHARGING CHARGING ADAPTER INDICATOR LED 12 VOLT DC POWER ADAPTER 120 VOLT AC RECHARGE PORT CHARGING RECHARGING THE BATTERY All lead acid batteries suffer from self discharge over time and more rapidly when they are used for prolonged periods or at higher temperatures Therefore these types of batteries need periodic charging to replace energy lost through self discharge The built in rechargeable battery should be recharged as soon as possible after each use If it is allowed to remain in a discharged state battery life will be reduced When the unit is not in frequent use recharge the unit at least once every 60 days Notes The unit is delivered in a partially charged state It MUST be fully charged before using it for the first time using the supplied AC Charging Adapter Initial AC charging time is approximately 20 hours Recharging the battery after each use will prolong battery life frequent heavy discharges between recharges will reduce battery life Overcharging will reduce battery life NEVER CHARGE FOR MORE THAN 36 HOURS The time required to fully recharge the built in battery depends on the charge status after use Approximate
3. latch is closed OO ON O amp O OG KR W NO USING THE LED WORK LIGHT The LED Work Light is controlled by the ON OFF Pushbutton located on the top of the unit behind the Nozzle Hatch see Controls and Functions on page 2 CARE AND MAINTENANCE Cleaning Periodically cables hose nozzles and connectors should be inspected for damage corrosion dust and dirt If surfaces are dirty they can be wiped clean with a cloth moistened with water and a drop of detergent Never submerge this unit in water or any other liquid Replacement Parts For replacement parts 12 Volt DC Power Adapters 120 Volt AC Charging Adapters contact Vector Technical Support toll free 866 584 5504 Fuse Replacement 12 Volt DC Power Adapter 1 Disconnect the 12 Volt DC Power Adapter from the unit and from any 12 volt DC power source Remove the gold cap by turning counterclockwise and lifting off Remove center pin and spring Remove the fuse Replace with a new 15 amp fuse Replace center pin and spring inside plug Oo OM KR W BN Replace the gold cap by turning clockwise 4 Battery Replacement Disposal Battery Replacement The built in battery should be replaced when the operating performance is reduced to about half Make sure that the battery is fully charged before determining whether it should be replaced The unit must be returned to the manufacturer for replacement Do not attempt to open the unit casing as this may dama
4. recharging time is 12 hours The AC Charging Adapter must be powered from a standard 120 volt AC 60 Hz North American household outlet 1 Insert the barrel connector of the AC Charging Adapter into the 120 Volt AC Recharge Port on the back of the unit Plug the AC Charging Adapter into a standard North American 120 volt AC household outlet The red Charging Indicator LED lights indicating the unit is charging 2 Charge for the recommended time Do not overcharge 3 Disconnect the AC Charging Adapter from the unit and the 120 volt AC power source when not in use 2 dh r POWERING THE UNIT The VEC251 can be powered by either the built in rechargeable battery or the 12 Volt DC Power Adapter Powering the Unit Using the Built In Rechargeable Battery The built in battery can power the compressor for short duration cordless operation The battery should be fully charged before first use see Charging Recharging the Battery Powering the Unit Using the 12 Volt DC Power Adapter The DC Power Adapter can operate the Air Compressor from an external 12 volt power source for extended periods of time The DC Power Adapter features a gold tipped fused DC plug at one end and a barrel connecter at the other Simply connect the gold tipped Alig to a working 12 volt DC power source such as a vehicle s 12 volt DC accessory outlet Connect the barrel connector to the 12 Volt DC Power Port on the back of the unit Note When usi
5. alve stem as far as possible before closing thumb latch 5 Press the Air Compressor Trigger to turn it ON for larger items engage the Trigger Lock 6 Observe pressure with the pressure gauge ED a VEC251 Manual _051306 qxp 5 17 06 3 58 PM Page 4 a SL 7 When desired pressure is reached open thumb latch and remove connector from valve stem 8 Release the Air Compressor Trigger to turn it OFF unlock the Trigger Lock if used Inflating Items Without Valve Stems Inflation of items without valve stems requires the use of one of the nozzles The nozzle fits directly in the free end of the tire chuck 1 Open the Nozzle Hatch cover and select the required nozzle With the tire chuck thumb latch open firmly insert the nozzle Close the tire chuck thumb latch Make sure the Nozzle is clean and secure before turning on the Compressor Insert nozzle e g needle into item to be inflated and inflate to desired pressure Press the Air Compressor Trigger to turn it ON Inflate to desired pressure Release the Air Compressor Trigger to turn it OFF After use release the Nozzle by opening the tire chuck thumb latch and return the nozzle to the Nozzle Hatch WARNING Always follow manufacturer s recommendations for pressure on item to be inflated A CAUTION To avoid damage always secure the Air Hose in its storage clamps when the unit is not in use Make sure the tire chuck thumb
6. ase date manufacturer will repair the unit or at its option replace it free of charge If the unit is repaired new or reconditioned replacement parts may be used at manufacturer s option A unit may be replaced with a new or reconditioned unit of the same or comparable design The repaired or replaced unit will then be warranted under the terms of the remainder of the warranty period The customer is responsible for the shipping charges on all returned items During the warranty period manufacturer will be responsible for the return shipping charges to the customer in the United States LIMITATIONS This warranty does not cover accessories such as charging adapters bulbs fuses and batteries damage or defects resulting from normal wear and tear lincluding chips scratches abrasions discoloration or fading due to usage or exposure to sunlight accidents damage during shipping to our service facility alterations Pa a y use or repair neglect misuse abuse Pilur to follow instructions for care and maintenance fire flood and Acts of God If your problem is not covered by this warranty call our Technical Support Department at 954 584 4446 or toll free at 866 584 5504 for general repair information and charges if applicable You may also contact us through our website at www vectormfg com STATE LAW RIGHTS This warranty gives you specific legal rights Some states do not allow limitations on how long an implied oie ee or the excl
7. ge the unit and will void the manufacturer s warranty Contact Vector Technical Support toll free at 866 584 5504 Battery Disposal This unit contains a maintenance free non spillable sealed lead acid battery This battery is fully recyclable and should be accepted at any location that accepts common automotive batteries Examples of places that accept these batteries are county or municipal recyclin drop off centers scrap metal dealers and retailers who sel automotive replacement lead acid batteries A WARNINGS Do not dispose of the battery in fire as this may result in an explosion Before disposing of the battery protect exposed terminals with heavy duty electrical tape to prevent shorting shorting can result in injury or fire Do not expose battery to fire or intense heat as it may explode SPECIFICATIONS Compressor 120 PSI maximum at pump a Current Approx 8 amps Battery 12 Volt 3 A h non spillable sealed lead acid 12 Volt DC Power Adapter Fuse 15 amp 5 E a
8. ng a vehicle s 12 volt DC accessory outlet as a power source be aware that some vehicles require the ignition be turned on to power the accessory outlet OPERATING INSTRUCTIONS This WEC251 is the ultimate compressor for vehicle and trailer tires and recreational inflatables Two different nozzles are supplied The Compressor ON OFF Trigger controls operation of the compressor Just depress and release to control inflation Control pressure by monitoring the gauge and releasing the Trigger when the correct pressure is achieved For longer inflation operations push Trigger Lock on to lock the Trigger in the ON position Pushing the Trigger Lock to the opposite direction releases the Trigger turning it OFF and inflation stops WARNINGS The compressor is capable of inflating to 120 pounds per square inch PSI pressure approximately 8 kg cm To avoid over inflation carefully follow instructions on articles to be inflated Never exceed recommended pressures Bursting articles can cause serious injury Always check pressure with the pressure gauge Never leave compressor unattended while in use Allow the unit to cool for 15 minutes after 15 minutes of continuous operation Inflating Items with Valve Stems 1 Unhook the Air Hose from its storage clamps 2 Open the thumb latch and place the connector chuck on valve stem 3 Push the connector toward valve stem and close the thumb latch 4 Make sure the connector is pushed on to v
9. pe Se y ay Seay ay mee ae Air Compressor with 2 LED Work Light Corded Cordless Rechargeable USER S MANUAL amp WARRANTY INFORMATION IMPORTANT SAFETY INFORMATION SAVE THESE INSTRUCTIONS TO REDUCE THE RISK OF INJURY USER MUST READ AND UNDERSTAND THIS INSTRUCTIONAL MANUAL THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING THE OPERATION AND WARRANTY OF THIS PRODUCT PLEASE RETAIN FOR FUTURE REFERENCE 4140 S W 30th Ave Ft Lauderdale FL 33312 Toll Free 866 584 5504 www vectormfg com E a VEC251 Manual _051306 qxp 5 17 06 3 58 PM Page ii IMPORTANT SAFETY INSTRUCTIONS WARNINGS 1 Wear protective goggles while operating these appliances There is risk of dust or dirt projectiles being released if the compressor hose or nozzles are not ean when the compressor is turned on 2 Do not direct air into eyes ears nose or other parts of the body 3 Do not operate unit if there is any evidence of damage Replace worn or defective parts immediately contact Vector Customer Service Department toll free at 866 584 5504 4 Make sure the AC Charging Adapter is kept away from water or moisture unng use If recharging near water make sure the 120 volt AC outlet is GFCI protected 5 Make sure all cords and adapter wires are placed so they are not tripped over or damaged by pinching abrading or cutting Do not place wires near moving objects doors or sharp objects 6 Never e
10. r offers the power of an advanced high pressure system with the convenience of mobile use The Air Compressor is supplied with a standard tire valve chuck for filling auto truck bicycle and motorcycle tires Also included are two different Nozzles to inflate soccer balls footballs and P ad inflatables These Nozzles are conveniently stored in a built in Nozzle Hatch The Air Compressor is powered by its own built in rechargeable battery to be used anywhere The supplied standard 120 Volt AC Charger can be used to recharge the battery when needed Typically up to three completely flat tires can be inflated before the battery needs recharging The unit can also operate from a standard 12 volt DC electrical system found on most vehicles and boats using the supplied DC Power Adapter if extended operating time in the field is required FEATURES e Trigger Switch with Trigger Lock to allow hands free operation e Corded use includes a DC Power Adapter for use with standard 12 volt DC power sources e Cordless use includes a rechargeable non spillable maintenance free heavy duty sealed high density lead acid battery e Supplied 120 Volt AC Charger is UL safety tested and listed e Battery Charging Indicator LED automatically activates during AC recharge e Built in clamps for storing Air Hose e Backlit Analog Pressure Gauge to 120 PSI e 2 Nozzles and Nozzle Hatch for storage e Built in long life 2 LED Work Light ES wy
11. ries that are not supplied or recommended by the manufacturer for use with this unit 9 Do not carry this unit by its cords or adapters as this can cause damage Never submerge the unit in water or any other liquid See Care and Maintenance on page 4 for cleaning instructions THIS UNIT IS NOT FOR USE BY CHILDREN AND SHOULD ONLY BE OPERATED BY ADULTS Read This User s Manual Before Using This Unit SAVE THESE INSTRUCTIONS as SZ TABLE OF CONTENTS Introduction Features Control and Function Guide cies eae eee se ae Bee bee ce aaehe ike 2 Charging Recharging the Battery 2 0 cee ee 2 Powe mo he Wintec bts ue narr ieee ea a ee er eS 3 Powering the Unit Using the Rechargeable Battery 0000 3 Powering the Unit Using the 12 Volt DC Power Adapter 3 Operating IMSiUCHONS 6 ieee te ee hes a ek anes eae Raw wie ee 3 Inflating Items With a Valve Stem eee 3 Inflating Items Without a Valve Stem 2 eee 4 Using the LED Work bight s lt 0l6 ue ee Com eee ees dete ieee heed 4 Care and Mainienahce siete eo hoe ee a A E ew ete eee hes 4 Replacement Paris mirese iiron Bet A ee es Sea a See A eS 4 Fuse Replacement 12 Volt DC Power Adapter 00000 0c eae 4 Battery Replacement Disposal o n nananana aa 5 PECCI e ra wu e a a a bee bem bee ee 5 INTRODUCTION Congratulations on purchasing the VEC251 Rechargeable Air Compressor with 2 LED Work Light The Air Compresso
12. usion or limitation of incidental or consequential damages so the exclusions or limitations stated herein may not apply This warranty gives the purchaser specific legal rights other rights which vary from state to state may apply TO REQUEST WARRANTY SERVICE FOR THIS PRODUCT Contact Technical Support by telephone fax or mail see below We suggest that you keep the original packaging in case you need to ship the unit When returning a product include your name address phone number dated sales receipt or copy and a description of the reason for return and product serial number After repairing or replacing the unit we will make every effort to return it to you within four weeks WARRANTY ACTIVATION Please complete Warranty Activation Card and mail to Vector Products Inc Enter VEC251 as Model and Airpro Rechargeable Air Compressor with 2 LED Work Light as Product Type All Vector products must be registered within 30 days of purchase to activate this warranty Mail the completed registration form along with a copy of the original sales receipt to ATTN CUSTOMER SERVICE 4140 SW 30th Ave Ft Lauderdale FL 33312 e TOLL FREE 866 584 5504 FAX 954 584 5556 WARRANTY IS NON TRANSFERABLE BDO51306 2006 VECTOR PRODUCTS INC MADE IN CHINA a SL VEC25 1 WECTO PO a peen e A A G d A G A ee 7 4 A G G ey a aa sy Se A ee ee ee ee a a
13. xceed recommended pressures bursting articles can cause serious injury Always check pressure with the pressure gauge 7 There are no user serviceable parts The only replaceable parts are the AC Charging Adapter the 12 Volt DC Power Adapter and the 12 Volt DC Power Adapter fuse 8 Never use air compressor near flammable liquids gas or open flames 9 Keep working area well lit 10 Never cover unit while it is operating CAUTIONS 1 When operating the Air Compressor using an external DC power source make sure the voltage is rated at 12 volts DC DO NOT OPERATE WITH 6 VOLTS OR 24 VOLTS 2 Do not use the Air Compressor continuously for longer than 15 minutes Extended use will cause it to overheat and can damage the product After 15 minutes of continuous use turn the unit OFF and wait 15 minutes before resuming operation 3 Make sure the built in battery is fully charged before operating Recharge for the recommended time after each use or every 60 days when not in frequent use to extend battery life For immediate use attach the 12 Volt DC Adapter and operate the unit from an external 12 volt DC source 4 Do not expose the unit to heat or direct sunlight 5 Do not charge the battery when it is at or above 122 F 50 C Allow the unit to cool before charging 6 To avoid over inflation carefully follow instructions on articles to be inflated 7 Never leave the unit unattended while in use 8 Do not use accesso