Home
Manual
Contents
1. Wall Mount Plate Mounting cccceeeeeeeeeeeeneees 12 Hardware Installation cccccccseeeeeeeeeeeeeeeeeees 13 Installation StEPS cc eccccccececeeeeecseeeeseeeeesseeeesseeeees 13 Network Application ccccccccccseeeseeeeeeeseeeeees 14 TROUDIESMOOUING is ceict sea cpsnteccant A 15 Technical SpecifiCation ccceseccseseeceseeeeeeeeeeeees 16 Introduction The 5 Port 10 100TX with 4 PoE Mode B Passive Injector Industrial Switch is a cost effective solution and meets the high reliability requirements demanded by industrial applications Besides the industrial switch provides the PoE function for kinds of Powered Devices to receive power as well as data over the RJ 45 cable Features System Interface Performance RJ 45 ports support Auto MDI MDI X Function Embedded 4 port PoE Injection Store and Forward Switching Architecture Back plane Switching Fabric 1 0Gbps 2K MAC Address Table Power Supply DC 48V Redundant Power Case Installation IP 30 Protection DIN Rail and Wall Mount Design Provides EFT protection 3 000 VDC for power line Supports 6 000 VDC Ethernet ESD protection Package Contents Please refer to the package contents list below to verify them against the checklist 5 Port 10 100TX with 4 PoE Mode B Passive Injector Industrial SwitchUser manual Pluggable Terminal Block 2 wall mount plates with screws Compare the contents of the industrial switch
2. s Ethernet port e g Switch PC or Server The UTP STP port RJ 45 LED on the Industrial switch will light up when the cable is connected with the network device Please refer to the LED Indicators section for LED light indication 7 When all connections are set and LED lights all show in normal the installation is complete Network Application This segment provides the sample to help user have more actual idea of industrial switch application For a sample application of the industrial switch see the figure below S Control Center Core Upper Level Switch Fiber Cable VOIP Phone IP Camera Wireless AP IEEE 802 3af Compliant Powered Devices Troubleshooting Verify that is using the right power cord adapter DC 48V please don t use the power adapter with DC output voltage higher than 48V or it will burn this equipment down Select the proper UTP STP cable to construct your network Please check that is using the right cable Use unshielded twisted pair UTP or shield twisted pair STP cable for RJ 45 connections 100 Q Category 3 4 or 5 cable for 10Mbps connections 100Q Category 5 cable for 100Mbps connections or 1000 Category 5e above cable for 1000Mbps Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet Diagnosing LED Indicators To assist in identifying problems the Switch can be easily monitored through panel indicators which describe common p
3. D 7 RD 8 TD 8 RD 4 RD 4 TD 5 RD 5 TD Cross Over Cable Schematic Cabling Twisted pair segment can be connected with unshielded twisted pair UTP or shielded twisted pair STP cable The cable must comply with the IEEE 802 3u 100Base TX standard for Category 5 The cable between the converter and the link partner switch hub workstation etc must be less than 100 meters 328 ft long Wiring the Power Inputs Please follow the steps below to insert the power wire V V V W Insert the positive and negative wires into the V and V contacts on the terminal block connector Tighten the wire clamp screws for preventing the wires from loosing Power Restriction under 48VDC power IPES OOO5T 4B only can support one 48VDC power source If using two 48VDC power source IPES 0005T 4B may cause damage 1 battery solution 1 negative power input site ground Rectifier 220VAC 48 VDC 1 battery solution 2 negative power input site ground Rectifier i X Vi 48 VDC Ya a Dual battery solution 2 negative power input different power souce site ground gt ez mm oad Rectifier P 220VAC E koa i 48 VDC ae 4 y2 n mi Rectifier j 220VAC 48 VDC j Wiring the Fault Alarm Contact The fault alarm contact is in the middle of terminal block connector as the picture shows below Inserting the wires it will detect the fault st
4. Lantech IPES OOO5T 4B 5 Port 10 100TX with 4 PoE Mode B Passive Injector Industrial Switch User Manual V1 01 Nov 2007 Recommendation for Shielded network cables STP cables have additional shielding material that is used to reduce external interference The shield also reduces the emission at any point in the path of the cable Our recommendation is to deploy an STP network cable in demanding electrical environments Examples of demanding indoor environments are where the network cable is located in parallel with electrical mains supply cables or where large inductive loads such as motors or contactors are in close vicinity to the camera or its cable It is also mandatory to use an STP cable where the power device like IP camera is used outdoors or where the network cable is routed outdoors Aluminum Foil Shield Twisted Pair Wires FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy It may cause harmful interference to radio communications if the equipment is not installed and used in accordance with the instructions However there is no guarantee that interference will not occur in a particular installation If this equipment does cause ha
5. allation Operating Temp Operating Humidity Storage Temperature Case Dimension EMI Stability testing 10Base T 2 pair UTP STP Cat 3 4 5 5e cable EIA TIA 568 100 ohm 100m 100Base TX 2 pair UTP STP Cat 5 5e cable EIA TIA 568 100 ohm 100m Redundant power DC 48V with connective removable terminal block 3 4Watts without PoE 57 Watts Full load with PoE DIN rail kit for DIN type cabinet install and wall mount ear for wall mounting 40 C to 75 C wide operating temperature model 20 C to 60 C standard model 5 to 95 Non condensing 40 C to 85 C IP 30 30mm W x 95mm D x 140mm H FCC Class A CE EN61000 4 2 3 4 5 6 8 1 1 12 CE EN61000 6 2 CE EN61000 6 4 CE EN60950 1 IEC60068 2 32 Free fall IEC60068 2 27 Shock IEC60068 2 6 Vibration
6. atus including power failure or port link failure managed industrial switch only and form an open circuit An application example for the fault alarm contact is shown as below Insert the wires into the fault alarm contact Note The wire gauge for the terminal block should be in the range between 12 24 AWG Mounting Installation DIN Rail Mounting The DIN Rail is screwed on the industrial switch when out of factory If the DIN Rail is not screwed on the industrial switch please see the following pictures to screw the DIN Rail on the switch Follow the steps below to hang the industrial switch Rear Side DIN Rail 1 Use the screws to screw the DIN Rail on the rear side of the industrial switch 2 To remove the DIN Rail reverse the step 1 3 After the DIN Rail is screwed on the rear side of the switch insert the top of DIN Rail into the track 4 Then lightly push the DIN Rail into the track 5 Check if the DIN Rail is tightened on the track or not 6 To remove the industrial switch from the track reverse steps above Wall Mount Plate Mounting Follow the steps below to mount the industrial switch with wall mount plate 1 Remove the DIN Rail from the industrial switch loose the screws to remove the DIN Rail 2 Place the wall mount plate on the rear panel of the industrial switch 3 Use the screws to screw the wall mount plate on the industrial switch 4 Use the hook holes at
7. nnected to network 1 5 RJ 45 Yellow On Full duplex link Lower Flashing Collision occurs LED Half duplex link or link down Ports RJ 45 ports The UTP RJ 45 Fast Ethernet ports will auto sense for 10Base T or 100Base TX connections Auto MDI MDIX means that the switch can connect to another switch or workstation without changing straight through or crossover cabling See the below figures for straight through and crossover cable schematic RJ 45 Pin Assignments 5 7 Note and signs represent the polarity of the wires that make up each wire pair All ports on this industrial switch support automatic MDI MDI X operation user can use straight through cables See figure below for all network connections to PCs or servers or to other switches or hubs In straight through cable pins 4 5 7 and 8 at one end of the cable are connected straight through to pins 4 5 7 and 8 at the other end of the cable The table below shows the 10BASE T 100BASE TX MDI and MDI X port pin outs Signal Name MDI Signal Name Receive Data plus RD Transmit Data plus TD Receive Data minus RD Transmit Data minus TD Transmit Data plus TD Receive Data plus RD Transmit Data minus TD Receive Data minus RD Switch Router or PC 7 8 4 5 TD gt 7 RD TD 8 RD RD lt __ 4 TD RD lt 5 _ TD Straight Through Cable Schematic Switch Router or PC 7 T
8. rmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate Measures Content MOGUC CUON or r aren oan eoeneaesenee 1 Foa OO aaa EE ata atoadateukes 1 Package COMES iiccteccsscacdincttasesonuancedyenanataatebaras 2 Hardware Description cccccseeceeeeeeeeeeeeeeees 3 PYVSICAL DIMENSION orses a doasebnsiahadeanersueee 3 PON ibe NGI path he teresa ete area eat aaia i ocean 3 SHOP WOW see ana tecianted ame aeaearnacenes 4 LED INGIC ALORS wexcctrazecctarieetecateansncuateterseneaataeaaeahs 5 Fe OS erecta tg aero ena ee sect eerie saad keence 6 COAG cona a E ab ntteumcatnenanee saaes 7 Wiring the Power Inputs ccsccesecseeeeeeeeeeeees 8 Wiring the Fault Alarm Contact cccccsseeeeeeeee 9 Mounting Installation cc cecceeeceeeeeeee eens 10 DIN alll VIQUMUING 2 aecaven cece i a 10
9. roblems the user may encounter and where the user can find possible solutions lf the power indicator does not light on when the power cord is plugged in user may have a problem with power cord Then check for loose power connections power losses or surges at power outlet If you still cannot resolve the problem contact the local dealer for assistance lf the Industrial switch LED indicators are normal and the connected cables are correct but the packets still cannot transmit Please check your system s Ethernet devices configuration or status Technical Specification The 5 10 100TX with 4 PoE Mode B Passive Injector Industrial Switch technical specifications is shown as below IEEE 802 3 10Base T Ethernet IEEE 802 3u 100Base IX Fast Ethernet Standard IEEE802 3x Flow Control and Back Pressure IEEE802 3af Power over Ethernet 14 880 pps for 10Base T Ethernet port Transfer Rate 148 800 pps for 100Base TX Fast Ethernet port MAC Address 2K MAC address table Connector 10 100TX 5 x RJ 45 with auto MDI MDI X function Supports 4 PoE injector function RJ 45 port 1 4 support PoE non standard B mode PoE Pin Positive VCC RJ 45 pin 4 5 Negative VCC RJ 45 pin 7 8 Data 1 2 3 6 Assignment Per unit Power 1 Green Power 2 Green Fault Red Per port Link Activity Green Full duplex Collision Yellow PoE Feeding Power Green Network Cable Power Supply Power Consumption Inst
10. the corners of the wall mount plate to hang the industrial switch on the wall 5 To remove the wall mount plate reverse steps above l Screw the wall mount plates on the Industrial Switch l l amn am am mm EE Em E E E E O E e O E E e e a e o ee e a al Hardware Installation In this paragraph we are going to mention how to install the 5 Port 10 100TX with 4 PoE Mode B Passive Injector Industrial Switch and the installation points to be attended to it Installation Steps 1 Unpack the Industrial switch packing 2 Check if the DIN Rail is screwed on the Industrial switch or not If the DIN Rail is not screwed on the Industrial switch please refer to DIN Rail Mounting section for DIN Rail installation If user want to wall mount the Industrial switch then please refer to Wall Mount Plate Mounting section for wall mount plate installation 3 To hang the Industrial switch on the DIN Rail track or wall please refer to the Mounting Installation section 4 Power on the Industrial switch Please refer to the Wiring the Power Inputs section for knowing the information about how to wire the power The power LED on the Industrial switch will light up Please refer to the LED Indicators section for indication of LED lights 5 Prepare the twisted pair straight through Category 5e above cable for Ethernet connection 6 Insert one side of the RJ 45 cable into the Industrial switch Ethernet port and another side to the network device
11. with the standard checklist above If any item is damaged or missing please contact the local dealer for service Hardware Description In this paragraph the Industrial switch s hardware spec port cabling information and wiring installation will be described Physical Dimension 5 Port 10 100TX with 4 PoE Mode B Passive Injector Industrial Switch Dimension W x D x H is 30mm x 95mm x 140mm Front Panel The Front Panel of the 5 Port 10 100TX with 4 PoE Mode B Passive Injector Industrial Switch is shown as below Front Panel of the PoE Injectors Industrial Switch Top View The top view of the 5 Port 10 100TX with 4 PoE Mode B Passive Injector Industrial Switch has one terminal block connector of two DC power inputs DC 48V PWR2 1A 24V PWRI Top View of the PoE Injectors Industrial Switch LED Indicators The diagnostic LEDs located on the front panel of the industrial switch provide real time information of system and optional status The following table provides the description of the LED status and their meanings for the switch Description Power input 1 is active Power input 1 is inactive Power input 2 is active Power input 2 is inactive Power input 1 or 2 has failed Power input 1 and 2 are both functional or no power inputs The port is supplying power to the powered device No powered device attached or power supplying fails Connected to network Flashing Networking is active Not co
Download Pdf Manuals
Related Search
Manual manual manualslib manual car manuale digitale manually meaning manual timesheet manual transmission manual wheelchair manually update your device drivers windows manual arts high school manual for courts martial manual definition manual labor manual lawn mower manual muscle testing manually register devices with autopilot manual muscle testing grades manualidades manual transfer switch manual therapy cpt code manual blood pressure cuff manual transmission cars for sale manual handling manual digital manual autopilot enrollment