Home
USER MANUAL - Rohde & Schwarz
Contents
1. 5 4 3 Figure 4 1 Rear Connections without Options Knockouts for system and user specific connections Analog bus connections Line Inlet Slots for Rear modules System module Oo amp ND 9th Issue 09 11 9th Issue 09 11 Test System Versatile Platform R amp S PowerTSVP TS PWA3 ROHDE amp SCHWARZ In its basic configuration the R amp S PowerTSVP only has the power connection 3 the analog bus connection 2 and the connector for the system module 5 All other connections are system and user specific System specific connectors e g D sub can be installed at the back of the R amp S PowerTSVP 1 You will find more details in Section 4 5 Cabling 4 4 3 Connections at the Front ROHDE amp SCHWARZ Test System Versatile Platform 4 Power Figure 4 2 Front Connections 1 Slots 16 The Test System Versatile Platform R amp S PowerTSVP has no connec tions in its basic configuration The existing slots can be fitted with sys tem and user specific plug in modules and connections Commissioning 4 7 ROHDE amp SCHWARZ Commissioning Test System Versatile Platform R amp S PowerTSVP TS PWA3 4 5 Cabling 4 5 1 Concept The R amp S PowerTSVP offers comprehensive options for inner internal and external cabling Inner cabling Cabling by bus systems permanently installed in the R
2. oc A Ww dD 9th Issue 09 11 9th Issue 09 11 amp SCHWARZ Test System Versatile Plattorm R amp S PowerTSVP TS PWA3 Interface description 8 6 4 Rear Panel X1 of Slot A1 Type 37 pin socket Pin Signal OI A Ww bd 13 GND 14 19 not wired 32 37 not wired 8 23 ROHDE amp SCHWARZ Interface description 8 24 Test System Versatile Platform R amp S PowerTSVP TS PWA3 9th Issue 09 11 9th Issue 09 11 ROHDE amp SCHWARZ Test System Versatile Platform R amp S PowerTSVP TS PWA3 TechnicalData 9 Technical Data NOTE Technical data for the Test System Versatile Platform R amp S PowerTSVP TS PWA3 is specified in the corresponding data sheets If there are discrepancies between the information in this operating manual and the values of the data sheet the val ues of the data sheet take precedence 9 1
3. 8 7 Table 8 8 Assignment of X1 X16 2 2 ee 8 9 Table 8 9 Assignment of X21 une een 8 10 Table 8 10 Assignment OT X22 ne 8 11 Table 8 11 Assignment of X13 8 12 Table 8 12 Assignment of 8 13 Table 8 13 Assignment of X16 ne nennen 8 13 Table 8 14 Assignment OF X1 nei id 8 14 Table 8 15 R amp S TS PSYS2 Assignment 20 8 16 Table 8 16 R amp S TS PSYS2 Assignment 0 8 17 Table 8 17 Assignment of X2 8 20 ROHDE amp SCHWARZ Tables 10 Test System Versatile Platform R amp S PowerTSVP TS PWA3 9th Issue 09 11 9th Issue 09 11 ROHDE amp SCHWARZ Test System Versatile Platform R amp S PowerTSVP TS PWA3 Userinformation 1 User Information 1 1 Foreword We congratulate you on your purchase of a ROHDE amp SCHWARZ Test System Versatile Platform R amp S PowerTSVP We would emphasize that only attendance at one of our regular in house training seminars can ensure your successful operation of the Test System Versatile Platform in the long term Please do not hesitate to contact us should you have any queries whilst working with the Test System Versatile Platform We look forward to working with you amp SCHWARZ GmbH amp Co KG 1 1 ROHDE amp SCHWARZ User Information 1 2 Test System Versatile Platform
4. You may be able to tell blown fuse just by looking at it In case of doubt test the fuse with a multimeter 9th Issue 09 11 9th Issue 09 11 Test System Versatile Platform R amp S PowerTSVP TS PWA3 ROHDE amp SCHWARZ WARNING You should identify the cause of the problem and rectify it before replacing the fuse Fuses are fitted reverse order of removal Maintenance ROHDE amp SCHWARZ Maintenance Test System Versatile Platform R amp S PowerTSVP TS PWA3 9th Issue 09 11 9th Issue 09 11 ROHDE amp SCHWARZ Test System Versatile Plattorm R amp S PowerTSVP TS PWA3 Plug In Modules 7 Plug In Modules 7 1 General Various types of plug in modules can be used in the R amp S PowerTSVP see Figure 7 1 Extended R amp S PowerTSVP ATE modules fitted depth 300 mm Rear I O modules Figure 7 1 Plug in modules in the R amp S PowerTSVP 7 1 ROHDE amp SCHWARZ Plug In Modules Test System Versatile Platform R amp S PowerTSVP TS PWA3 Connectors and connector shells to DIN 41612 suitable for the front connectors of the plug in modules are available from a number of sup pliers including Siemens with the following reference numbers Case C42334 Z61 C2 Locking lever left C42334 Z61 C11 Locking lever right C42334 Z261 C12 Round cable insert 42334 261 16 96 way plug connectortype R V42254 B1240 R960 WireWrap Other suppliers include Harting shells and co
5. 3 6 Figure 3 5 BW 2000 CaSe 3 7 Figure 3 6 Plan View example ae 3 8 Figure 3 7 Side VIEW m 3 9 Figure 3 8 Backplanes and Bus Systems 3 9 Figure 3 9 A Ann 3 10 Figure 3 10 Mountable Threaded Studs on the Control Backplane 3 12 Figure 3 11 Principle of the Analog Bus 3 14 Figure 3 12 Use of the Analog Bus in the R amp S PowerTSVP Example 3 15 Figure 3 13 Ground Concept ini ais 3 18 Figure 3 14 Configuration example TS PCA3 und TS PWAQ3 3 21 Figure 3 15 Layout of Fans in the Frame 3 24 Figure 3 16 Circuit Diagram of the RES 5 2 3 26 Figure 3 17 Connectors and Jumpers on the R amp S TS PSYS2 3 27 Figure 3 18 Module Configuration TS PWAS 3 33 Figure 4 1 Rear Connections without Options 4 6 Figure 4 2 Front CONNECHONS aiiis peus pa ina pe asnicar 4 7 Figure 4 3 Inner and Internal Cabling Variants 4 8 Figure 4 4 R amp S PowerTSVP Rear View 4 11 Figure 6 1 R amp S PowerTSVP Rear View 6 2 Figure 7 1 Plug in modules in the R amp S PowerTSVP 7 1 Figure 8 1 Control Backplane Front View eere 8 1 Fig
6. P47 9th Issue 09 11 9th Issue 09 11 ROHDE amp SCHWARZ Test System Versatile Platform R amp S PowerTSVP TS PWA3 Interface description Pin 2 Signal Name Description 36 V3SENSE V3 Remote Sense 37 M Reserved 38 M DEG Degrade Signal 39 M INH Inhibit 40 Reserved 3 41 V2SHARE V2 Current Share 42 FAL Fail Signal 43 Reserved 3 44 M V3SHARE V3 Current Share 45 E CGND Chassis Ground 46 M CAN AC Input Neutral 47 M ACL AC Input Line Table 8 3 Assignment P47 1 Pin numbers illustrated are of the female backplane connector z L long length pins M medium length pins S short length pins 3 For future options 8 5 ROHDE amp SCHWARZ Interface description Test System Versatile Plattorm R amp S PowerTSVP TS PWA3 8 1 4 ATX Connectors Table 8 4 ATX Connector Assignment 8 1 5 Fan Connectors X90 X91 X92 X93 Pin Signal FANCTRL 12V 4 3 2 NC 1 Table 8 5 Assignment of X90 GND X93 Pin Signal Signal Pin 12 V3 Current Share V2 Current Share 24 11 5 V Sense 3 3 V Sense 23 10 12V 5 V 22 9 FAL V1 Current Share 21 8 PW OK PRST 20 7 GND Sense GND 19 6 5 V GND 18 5 GND GND 17 4 5 V PS ON 16 3 GND GND 15 2 3 3 V 12V 14 1 3 3 V 3 3 V 13 9th Issue 09 11 9th Issue 09 11 Test System Versatile Platform R8S PowerTSVP TS PWA3
7. PxITRIG1 PxiTRIGO LBRSV DcSYNC cn TRIGO PX TRIG3 PXI TRIG4 PXI eno ADS AD 48 c2 gt O gt E 0 ADI5 VO A V UO C BE 7 PXI_LBR8 ENEE o 2 2 zZ 2 4 PXI LBL6 LBL7 rs d au ES Y 2 200 mima a GND 9th Issue 09 11 GND ax s co END OD CND GND GND L GND GND 5V 2 200 Table 8 2 Connector P20 as from Serial Number 100021 Slots 1 16 ROHDE amp SCHWARZ Interface description Test System Versatile Platform R amp S PowerTSVP TS PWA3 8 1 3 Connector X0 P47 47 45 44 42 23 21 20 19 Figure 8 5 Connector 47 Mating Side Pin 2 Signal Name Description 1 4 M V1 V1 Output 5 12 M RTN V1 and V2 Return 13 18 V2 V2 Output 19 M RTN V3 Return 20 M V3 Output 21 4 V4 Output 22 M RTN Signal Return 23 M Reserved Reserved 24 M RTN V4 Return 25 M Reserved 3 26 M Reserved Reserved 27 ENF Enable 28 M Reserved 3 29 M NC Not connected 30 M VISENSE V1 Remote Sense 31 M Reserved 3 32 N NC Not connected 33 M V2SENSE V2 Remote Sense 34 SRTN Sense Return 35 VISHARE V1 Current Share Table 8 3 Assignment
8. N No sit e el producto encima de superficies veh culos estantes o mesas que por sus caracter sticas de peso o de estabilidad no sean aptos para l Siga siempre las instrucciones de instalaci n del fabricante cuando instale y asegure el producto en objetos o estructuras p ej paredes y estantes Si se realiza la instalaci n de modo distinto al indicado en la documentaci n del producto pueden causarse lesiones o incluso la muerte d No ponga el producto sobre aparatos que generen calor p ej radiadores o calefactores La temperatura ambiente no debe superar la temperatura m xima especificada en la documentaci n del producto o en la hoja de datos En caso de sobrecalentamiento del producto pueden producirse choques el ctricos incendios y o lesiones graves con posible consecuencia de muerte 1171 0000 42 05 00 Page 8 Informaciones elementales de seguridad Seguridad el ctrica Si no se siguen o se siguen de modo insuficiente las indicaciones del fabricante en cuanto a seguridad el ctrica pueden producirse choques el ctricos incendios y o lesiones graves con posible consecuencia de muerte 1 10 11 Antes de la puesta en marcha del producto se deber comprobar siempre que la tensi n preseleccionada en el producto coincida con la de la red de alimentaci n el ctrica Si es necesario modificar el ajuste de tensi n tambi n se deber n cambiar en caso dado los fusibles correspondientes del producto
9. 8 1 6 Expansion Connector X80 ROHDE amp SCHWARZ Interface description Pin Signal Signal Pin 1 PS ON GND 2 3 PW OK GND 4 5 RESERVED GND 6 7 CAN H CAN L 8 9 N C N C 10 11 3 3 V GND 12 13 5V GND 14 15 12V GND 16 17 12V GND 18 19 12V GND 20 Table 8 6 Assignment of X80 8 1 7 Jumper Field J1 4 42 J3 PS ON J4 TERM_CAN_L J5 TERM_CAN_H Table 8 7 Jumper Field Assignment ROHDE amp SCHWARZ Interface description Test System Versatile Platform R amp S PowerTSVP TS PWA3 8 2 Analog Bus Backplane 8 2 1 Position of Interfaces Slot1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 X16 Figure 8 6 Analog Bus Backplane Front View to Analog Bus Connector X2 TITIIITITITITTTITEES 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 Slotl Figure 8 7 Analog Bus Backplane Rear View 8 8 9th Issue 09 11 9th Issue 09 11 amp SCHWARZ Test System Versatile Platform R amp S PowerTSVP TS PWA3 Interface description 8 2 2 Analog Bus Connectors X1 X16 D N 000006000 C0000 Oja 00000 0 M oO A Figure 8 8 Connectors X1 X16 Mating Side Pin A B C D E 7 Ix IL2 x 6 GND 5 ABal ABc1 4 ABb1 3 ABb2 ABc2 2 ABa2 1 ABd1 ABd2 Table 8 8 Assignment of X1 X16 Note IL1 x IL1 o
10. An electrically conductive CHA GND chassis GND pad in the mount ing area on the control backplane provides an impedance grounding to the chassis Screw connections and a busbar on the control backplane are used to make a low resistance connection for GND and CHA GND while a star connection between GND and CHA GND using a busbar prevents unwanted ground loops A capacitor creates the HF connection between GND and CHA GND at each slot A 1 MOhm resistor discharges the capacitors and dissipates static A 3 pin connector provides the 230 VAC supply for the PSU on the con trol backplane at XO The optional power backplane is supplied with AC voltage parallel to the control backplane The PE conductor must be bonded to the case with a grounding cable The GND signal of the analog bus backplane is connected by a cable and screw terminal to the GND on the cPCI backplane This prevents the large induction loops that would occur if a return via chassis were to be used The ground screen of the analog bus between two R amp S PowerTSVP is connected to CHA GND chassis In the second R amp S PowerTSVP CHA GND must not be connected to GND to prevent ground loops The connections are sketched in Figure 3 13 GND sense of 5 V and 3 3 V of the second PSU as well are con nected to GND at the grounding star point Description 3 17 ROHDE amp SCHWARZ Description Test System Versatile Platform R amp S PowerTSVP TS PWA3 AC Input
11. Informaciones elementales de seguridad Si un producto se instala en un lugar fijo se deber primero conectar el conductor de protecci n fijo con el conductor de protecci n del producto antes de hacer cualquier otra conexi n La instalaci n y la conexi n deber n ser efectuadas por un electricista especializado En el caso de dispositivos fijos que no est n provistos de fusibles interruptor autom tico ni otros mecanismos de seguridad similares el circuito de alimentaci n debe estar protegido de modo que todas las personas que puedan acceder al producto as como el producto mismo est n a salvo de posibles da os Todo producto debe estar protegido contra sobretensi n debida p ej a una ca da del rayo mediante los correspondientes sistemas de protecci n Si no el personal que lo utilice quedar expuesto al peligro de choque el ctrico No debe introducirse en los orificios de la caja del aparato ning n objeto que no est destinado a ello Esto puede producir cortocircuitos en el producto y o puede causar choques el ctricos fuego o lesiones Salvo indicaci n contraria los productos no est n impermeabilizados ver tambi n el cap tulo Estados operativos y posiciones de funcionamiento punto 1 Por eso es necesario tomar las medidas necesarias para evitar la entrada de l quidos En caso contrario existe peligro de choque el ctrico para el usuario o de da os en el producto que tambi n pueden redundar en peligro p
12. Los productos de la clase de protecci n con alimentaci n m vil y enchufe individual solamente podr n enchufarse a tomas de corriente con contacto de seguridad y con conductor de protecci n conectado Queda prohibida la interrupci n intencionada del conductor de protecci n tanto en la toma de corriente como en el mismo producto La interrupci n puede tener como consecuencia el riesgo de que el producto sea fuente de choques el ctricos Si se utilizan cables alargadores o regletas de enchufe deber garantizarse la realizaci n de un examen regular de los mismos en cuanto a su estado t cnico de seguridad Si el producto no est equipado con un interruptor para desconectarlo de la red se deber considerar el enchufe del cable de conexi n como interruptor En estos casos se deber asegurar que el enchufe siempre sea de f cil acceso de acuerdo con la longitud del cable de conexi n aproximadamente 2 m Los interruptores de funci n o electr nicos no son aptos para el corte de la red el ctrica Si los productos sin interruptor est n integrados en bastidores o instalaciones se deber colocar el interruptor en el nivel de la instalaci n No utilice nunca el producto si est da ado el cable de conexi n a red Compruebe regularmente el correcto estado de los cables de conexi n a red Aseg rese mediante las medidas de protecci n y de instalaci n adecuadas de que el cable de conexi n a red no pueda ser da ado o de que nadie
13. general Caution Danger of Warning PE terminal Ground Ground Be careful when danger location when electric Hot surface terminal handling handling shock electrostatic Observe product heavy sensitive documentation equipment devices ON OFF supply voltage Standby indication Direct current DC AC Alternating current Direct alternating current DC AC Device fully protected by double reinforced insulation 1171 0000 42 05 00 Page 1 Basic Safety Instructions Tags and their meaning The following signal words are used in the product documentation in order to warn the reader about risks and dangers indicates a hazardous situation which if not avoided will result in death or 4 DANGER serious injury indicates a hazardous situation which if not avoided could result in death or indicates a hazardous situation which if not avoided could result in minor or moderate injury indicates the possibility of incorrect operation which can result in damage to NOTICE the product In the product documentation the word 1 used synonymously These tags are in accordance with the standard definition for civil applications in the European Economic Area Definitions that deviate from the standard definition may also exist in other economic areas or military applications It is therefore essential to make sure that the tags described here are always used only in connection with the
14. pueda ser da ado por l p ej al tropezar o por un choque el ctrico Solamente est permitido el funcionamiento en redes de alimentaci n TN TT aseguradas con fusibles de 16 A como m ximo utilizaci n de fusibles de mayor amperaje solo previa consulta con el grupo de empresas Rohde 8 Schwarz Nunca conecte el enchufe en tomas de corriente sucias o llenas de polvo Introduzca el enchufe por completo y fuertemente en la toma de corriente La no observaci n de estas medidas puede provocar chispas fuego y o lesiones No sobrecargue las tomas de corriente los cables alargadores o las regletas de enchufe ya que esto podr a causar fuego o choques el ctricos En las mediciones en circuitos de corriente con una tensi n gt 30 V se deber n tomar las medidas apropiadas para impedir cualquier peligro p ej medios de medici n adecuados seguros limitaci n de tensi n corte protector aislamiento etc Para la conexi n con dispositivos inform ticos como un PC o un ordenador industrial debe comprobarse que stos cumplan los est ndares IEC60950 1 EN60950 1 o IEC61010 1 EN 61010 1 v lidos en cada caso A menos que est permitido expresamente no retire nunca la tapa ni componentes de la carcasa mientras el producto est en servicio Esto pone a descubierto los cables y componentes el ctricos y puede causar lesiones fuego o da os en el producto 1171 0000 42 05 00 Page 9 12 13 14 15 16 17 18
15. 3 3 3 Backplanes The R amp S PowerTSVP contains the following backplanes Control backplane with PICMG Power Interface and Rear sup port e Analog Bus Backplane e Power backplane with PICMG Power Interface optional Figure 3 8 shows the backplanes with the bus systems The assign ment of the connectors is detailed in Section 8 LI Figure 3 8 Backplanes and Bus Systems R amp S Anlog bus a PXI Sync bus ext Power e CAN bus Slot 1 2 3 4 5 6 T 8 9 10 11 12 13 14 15 16 ROHDE amp SCHWARZ Description 3 10 Test System Versatile Platform R amp S PowerTSVP TS PWA3 3 3 3 1 Control Backplane The control backplane is implemented for 16 plug in modules to R amp S format with front slots The P2 connector of the cPCI system is used for the control interface Pin assignment is R amp S specific designation P20 and compatible with the R amp S CompactTSVP so plug in modules for the R amp S PowerTSVP can also be operated in the R amp S Com pactTSVP Connector P47 serves as a power interface for a cPCI standard PSU An additional PSU can be plugged onto an optional power back plane in which case the connection with the control backplane is made with an ATX power supply cable Support for the Rear I O concept according to Standard IEEE 1101 11 1998 is implemented for P20 Voltages up to 125 VDC can be routed in the Rear area The PXI trigger bus according to P
16. Additional Signals 3 11 ROHDE amp SCHWARZ Description Test System Versatile Platform R amp S PowerTSVP TS PWA3 Lines with 5 V and 12 V are taken from connector P47 to option al threaded studs This makes it easy to connect AUX1 to 5 V and AUX2 to 12 V e g using an optional bus bar or cable see Figure 3 10 Mountable Threaded Studs option eo 0000000 0 2 Slot 1 Figure 3 10 Mountable Threaded Studs on the Control Backplane 3 12 9th Issue 09 11 9th Issue 09 11 ROHDE amp SCHWARZ Test System Versatile Platform R amp S PowerTSVP TS PWA3 Description 3 3 3 2 Analog Bus Backplane To make cabling easy the R amp S PowerTSVP contains an analog bus with 8 signals to facilitate the noise immune and variable connection of switching modules and measuring instruments The analog bus back plane is located in the front section above the control backplane Re quirements for high crosstalk attenuation and low capacitance of the signal lines to GND are met by a special layout The C module 2 mm connector system is used as the connectors X1 X16 Plug in modules with no analog bus connector access the analog bus via a 26 pin connector X22 and R amp S switch modules Sig nals IL1 x and IL2 x Instrument Line are passed from slots 5 to 16 to connector X22 see Section 4 4 2 The analog bus signals pass from connector X21 to connector X2 atthe back of the R a
17. PE N L a Analog bus Analog bus Power Filter L GND GND 4 e o Screen power CHA GND GN CHA GND GND Back plane Control Backplane Control Backplane PowerTSVP Rack connection PowerTSVP Figure 3 13 Ground Concept 3 3 5 Geographical Addressing of the Slots with GAO GA5 The physical slot addresses are coded with the signals GAO GA5 see cPCI specification For slot 1 are connected to GND In order to distinguish between slots of different connected R amp S Pow erTSVP basic units GA4 and GAS are configured with jumpers see jumper field in Section 8 3 18 9th Issue 09 11 9th Issue 09 11 ROHDE amp SCHWARZ Test System Versatile Platform R amp S PowerTSVP TS PWA3 Description The coding for slot recognition is carried out with as fol lows Slot Code 1 0000 2 0001 3 0010 4 0011 5 0100 6 0101 7 0110 8 0111 9 1000 10 1001 11 1010 12 1011 13 1100 14 1101 15 1110 16 1111 Note 0 Pin connected to GND via resistor 1 Pin open 3 3 6 CAN Bus For controlling of the switch modules R amp S TS PMB and R amp S TS PSM1 as well as the control modules R amp S TS PSYS1 and R amp S TS PSYS2 the CAN bus is used in TS PCA3 and TS PWA3 The CAN bus num bering results from the following scheme CANu VW X Board Number v Controller
18. PSYS2 Connector X30 30 ROHDE amp SCHWARZ Interface description Figure 8 14 R amp S TS PSYS2 Connector X30 Mating Side Table 8 16 R amp S TS PSYS2 Assignment X30 Pin Signal Pin Signal Pin Signal 1 AUX1 16 CLK10 IN 31 TRIGO 2 AUX2 17 CLK10 OUT 32 TRIG1 3 AUX3 18 Reserved 33 TRIG2 4 AUX4 19 GND 34 TRIG3 5 AUX5 20 4 5 V 35 TRIG4 6 AUX6 21 11 5V 36 TRIG5 7 TEMP OUT 22 GND 37 TRIG6 8 OUT1 COM 23 OUT1 NO 38 TRIG7 9 OUT2 COM 24 OUT2_NO 39 CAN2_H 10 OUT3_COM 25 OUT3_NO 40 CAN2_L 11 OUT4 COM 26 OUT4_NO 41 CAN1_H 12 IN1 H 27 IN1 L 42 1 L 13 IN2 H 28 IN2 L 43 GND 14 IN3 H 29 IN3 L 44 CHA GND 15 IN4_H 30 IN4_L 8 17 ROHDE amp SCHWARZ Interface description 8 18 Test System Versatile Platform R amp S PowerTSVP TS PWA3 8 4 3 R amp S TS PSYS2 Jumper Field X40 DC SYNC Figure 8 15 Signals at the R amp S TS PSYS2 Jumper Field X40 8 4 4 R amp S TS PSYS2 Jumper JP2 CLK10 IN EXT PXI_CLK10 CLK10_LOCAL Figure 8 16 Signals at the R amp S TS PSYS2 Jumper JP2 8 4 5 R amp S TS PSYS2 Jumper JP6 and JP7 CAN1 X20 Transceiver JP6 Figure 8 17 R amp S TS PSYS2 Jumper JP6 and JP7 9th Issue 09 11 9th Issue 09 11 ROHDE amp SCHWARZ Test System Versatile Platform R amp S PowerTSVP TS PWA3 Interface description 8 4 6 R amp S TS PSYS2 Jumper JP8 CLK10 OUT X30 17 Figure 8 18 Signal at the
19. PWA3 Contents Contents 1 User Information 1 1 1 1 Foreword 1 1 1 2 Related Documentation 1 2 1 3 Purpose of the User Manual 1 3 1 4 Explanation of Symbols 1 4 2 Safety 2 1 2 1 General 2 1 2 2 Safety Instructions 2 1 3 Description 3 1 3 1 Usage 3 1 3 1 1 General 3 1 3 1 2 Explanation of Terms 3 2 3 1 3 System Information 3 3 3 2 Views 3 5 3 3 Layout 3 7 3 3 1 Case 3 7 3 3 2 Slot Layout 3 8 3 3 2 1 Plan View 3 8 3 3 2 2 Side View 3 9 3 3 3 Backplanes 3 9 3 3 3 1 Control Backplane 3 10 3 3 3 2 Analog Bus Backplane 3 13 3 3 3 3 Power Backplane 3 16 3 3 3 4 Backplane Extension R amp S TS PXB2 Option 3 16 3 3 4 Ground Concept 3 17 3 3 5 Geographical Addressing of the Slots with GAO GA5 3 18 3 3 6 CAN Bus 3 19 3 3 7 Configurations with several Frames or Option R amp S TS PXB2 3 21 3 3 8 Switching the PSU 3 22 3 3 9 Line Inlet and Power Switch 3 22 3 3 10 Cooling 3 23 3 4 System Module R amp S TS PSYS2 3 25 3 4 1 General 3 25 3 4 2 Characteristics 3 25 3 4 3 Circuit Diagram of the R amp S TS PSYS2 3 26 ROHDE amp SCHWARZ Contents 3 5 3 6 3 4 4 3 4 5 3 4 5 1 3 4 5 2 3 4 5 3 3 4 5 4 3 4 5 5 3 4 6 3 4 7 Test System Versatile Platform R amp S PowerTSVP TS PWA3 Structure of the R amp S TS PSYS2 Functional Description of the R amp S TS PSYS2 Control System Functions System Clock Signal Looping Local Signal Outputs Driver Software Self Test Function Description
20. Permitted Module Configurations 4 Commissioning 4 1 Safety Instructions 4 2 Setting Up 4 2 1 Requirements for Repeatable Measurements 4 2 2 Rack Mounting 4 2 3 Desktop Setup 4 2 4 Operating Position 4 3 Installation 4 3 1 Safety Instructions 4 3 2 Compatibility 4 3 3 Module Installation 4 3 4 Driver Installation 4 4 Connections 4 4 1 Line Inlet 4 4 2 Connections at the Rear 4 4 3 Connections at the Front 4 5 Cabling 4 5 1 Concept 4 5 2 Analog bus 4 5 3 PXI Trigger Bus 4 5 4 External Cabling 4 5 5 Opening the Case 5 Operation 5 1 General 5 2 Self Test 3 26 3 28 3 28 3 28 3 29 3 30 3 30 3 31 3 31 3 31 3 32 4 1 4 1 4 1 4 1 4 1 4 2 4 3 4 4 4 4 4 4 4 4 4 5 4 6 4 6 4 6 4 7 4 8 4 8 4 9 4 10 4 10 4 10 5 1 5 1 9th Issue 09 11 9th Issue 09 11 Test System Versatile Platform R amp S PowerTSVP TS PWA3 Maintenance 6 1 Important User Information 6 2 Cleaning 6 3 Fuse Replacement Plug In Modules 7 1 General 7 2 Configuration Instructions Interface Description 8 1 Control Backplane 8 1 1 Position of Interfaces 8 1 2 Connector P20 Slots 1 16 8 1 3 Connector X0 P47 8 1 4 ATX Connectors 8 1 5 Fan Connectors X90 X91 X92 X93 8 1 6 Expansion Connector X80 8 1 7 Jumper Field 8 2 Analog Bus Backplane 8 2 1 Position of Interfaces 8 2 2 Analog Bus Connectors X1 X16 8 2 3 Analog Bus Connector X21 8 2 4 Analog Bus Connector X22 8 3 Power Backplane Option 8 3 1
21. R amp S TS PSYS2 Jumper JP8 8 19 ROHDE amp SCHWARZ Interface description 8 20 Test System Versatile Platform R amp S PowerTSVP TS PWA3 8 5 External Analog Interface 8 5 1 Analog Bus Connector X2 The analog bus connector X2 is located at the back of the R amp S Pow erTSVP and is connected to analog bus connector X21 on the analog bus backplane 9 Figure 8 19 Analog Bus Connector X2 Mating Side Pin Signal GND ABc1 GND ABc2 GND ABa2 GND ABd2 GND ABa1 GND ABb1 GND 14 ABb2 15 ABd1 Table 8 17 Assignment of X2 N wo 9th Issue 09 11 9th Issue 09 11 ROHDE amp SCHWARZ Test System Versatile Platform R amp S PowerTSVP TS PWA3 Interface description 8 6 Backplane Extension R amp S TS PXB2 Option NOTE The colours the tables serve for highlighting entire ports 8 6 1 Jumpers X10 if plugged X11 GA4 0 if plugged X12 5 V available at the rear I O slot A4 CAN available if plugged 8 6 2 Rear panel slot A4 CAN Type 9 pin socket Pin Signal CAN_L GND GND CAN_H 5V JXJ O O N 8 21 ROHDE amp SCHWARZ Interface description 8 22 Test System Versatile Platform R amp S PowerTSVP TS PWA3 8 6 3 Rear Panel Slot A4 DIO of Slot A2 Type 25 pin socket Pin Signal
22. Safety Instructions Always read through and comply with the following safety instructions All plants and locations of the Rohde 8 Schwarz group of companies make every effort to keep the safety standards of our products up to date and to offer our customers the highest possible degree of safety Our products and the auxiliary equipment they require are designed built and tested in accordance with the safety standards that apply in each case Compliance with these standards is continuously monitored by our quality assurance system The product described here has been designed built and tested in accordance with the attached EC Certificate of Conformity and has left the manufacturer s plant in a condition fully complying with safety standards To maintain this condition and to ensure safe operation you must observe all instructions and warnings provided in this manual If you have any questions regarding these safety instructions the Rohde 8 Schwarz group of companies will be happy to answer them Furthermore it is your responsibility to use the product in an appropriate manner This product is designed for use solely in industrial and laboratory environments or if expressly permitted also in the field and must not be used in any way that may cause personal injury or property damage You are responsible if the product is used for any intention other than its designated purpose or in disregard of the manufacturer s instructions The manufacturer sh
23. Utility Connector X13 Pin Signal Signal Pin 1 PRST FAL 6 2 DEG 3 3 V Sense 7 3 3 3V GND Sense 3 3V 8 4 5V 5V Sense 9 5 GND GND Sense 5V 10 Table 8 11 Assignment of X13 8 12 9th Issue 09 11 9th Issue 09 11 ROHDE amp SCHWARZ Test System Versatile Platform R amp S PowerTSVP TS PWA3 Interface description 8 3 3 Power Backplane ATX Connector X12 Pin Signal Signal Pin 10 12V 5 20 9 5 Y 19 8 PW OK NC 18 7 GND GND 17 6 5 GND 16 5 GND GND 15 4 5 V PS ON 14 3 GND GND 13 2 3 3 V 12 V 12 1 3 3 V 3 3 V 11 Table 8 12 Assignment of X12 8 3 4 Power Backplane Connector X16 Pin Signal 1 V1 Current Share 2 V2 Current Share 3 V3 Current Share 4 NC Table 8 13 Assignment of X16 8 13 ROHDE amp SCHWARZ Interface description Test System Versatile Platform R amp S PowerTSVP TS PWA3 8 3 5 Power Backplane Connector X1 P47 47 45 44 42 23 21 20 19 Figure 8 12 Connector X1 47 Mating Side Pin 1 2 Signal Name Description 1 4 M V1 V1 Output 5 12 M RTN V1 and V2 Return 13 18 V2 V2 Output 19 M RTN V3 Return 20 M V3 V3 Output 21 4 V4 Output 22 M RTN Signal Return 23 M Reserved Reserved 24 M RTN V4 Return 25 M Reserved 3 26 M Reserved Reserved 27 ENF Enable 28 M Reserved 3 29 M NC N
24. amp Schwarz se producen reacciones al rgicas como p ej irritaciones cut neas estornudos continuos enrojecimiento de la conjuntiva o dificultades respiratorias debe avisarse inmediatamente a un m dico para investigar las causas y evitar cualquier molestia o da o a la salud Antes de la manipulaci n mec nica y o t rmica o el desmontaje del producto debe tenerse en cuenta imprescindiblemente el cap tulo Eliminaci n punto 1 1171 0000 42 05 00 Page 10 5 Informaciones elementales de seguridad Ciertos productos como p ej las instalaciones de radiocomunicaci n RF pueden a causa de su funci n natural emitir una radiaci n electromagn tica aumentada Deben tomarse todas las medidas necesarias para la protecci n de las mujeres embarazadas Tambi n las personas con marcapasos pueden correr peligro a causa de la radiaci n electromagn tica El empresario operador tiene la obligaci n de evaluar y se alizar las reas de trabajo en las que exista un riesgo elevado de exposici n a radiaciones Tenga en cuenta que en caso de incendio pueden desprenderse del producto sustancias t xicas gases l quidos etc que pueden generar da os a la salud Por eso en caso de incendio deben usarse medidas adecuadas como p ej m scaras antig s e indumentaria de protecci n En caso de que un producto Rohde amp Schwarz contenga un producto l ser ej un lector de CD DVD no debe usarse ninguna otra configuraci n o funci n
25. amp SCHWARZ Test System Versatile Platform R amp S PowerTSVP TS PWA3 Description 3 2 Views Figure 3 2 and Figure 3 3 show the R amp S PowerTSVP with slots cov ered Test System Versatile Platform Power SV Figure 3 2 Front View ANALOG Figure 3 3 Rear View 3 5 ROHDE amp SCHWARZ Description Test System Versatile Platform R amp S PowerTSVP TS PWA3 The R amp S PowerTSVP can be operated with an adapter interface op tional which is flange mounted to the front panel see Figure 3 4 Figure 3 4 Adapter Interface 9th Issue 09 11 9th Issue 09 11 ROHDE amp SCHWARZ Test System Versatile Platform R amp S PowerTSVP TS PWA3 Description 3 3 Layout 3 3 1 Case The R amp S PowerTSVP uses the standard Rohde amp Schwarz case of the Design 2000 see Figure 3 5 The characteristics of the case are summarized in the Table 3 2 Figure 3 5 BW 2000 Case HF immune case to Rohde amp Schwarz Design 2000 Dimensions 19 height 4U 430mm deep Use as desktop unit or rack mounted case Mounted in 19 rack using the telescopic slide set or on support rails Side case handles that remain on the unit when mounted in the rack Four rugged detachable rubber feet provide rear protection Unused slots can be covered by front sub panels that maintain the integrity of the HF im
26. aparte de las descritas en la documentaci n del producto a fin de evitar lesiones p ej debidas a irradiaci n l ser Reparaci n y mantenimiento 1 El producto solamente debe ser abierto por personal especializado con autorizaci n para ello Antes de manipular el producto o abrirlo es obligatorio desconectarlo de la tensi n de alimentaci n para evitar toda posibilidad de choque el ctrico El ajuste el cambio de partes el mantenimiento y la reparaci n deber n ser efectuadas solamente por electricistas autorizados por Rohde 8 Schwarz Si se reponen partes con importancia para los aspectos de seguridad p ej el enchufe los transformadores o los fusibles solamente podr n ser sustituidos por partes originales Despu s de cada cambio de partes relevantes para la seguridad deber realizarse un control de seguridad control a primera vista control del conductor de protecci n medici n de resistencia de aislamiento medici n de la corriente de fuga control de funcionamiento Con esto queda garantizada la seguridad del producto Bater as y acumuladores o celdas Si no se siguen o se siguen de modo insuficiente las indicaciones en cuanto a las bater as y acumuladores o celdas pueden producirse explosiones incendios y o lesiones graves con posible consecuencia de muerte El manejo de bater as y acumuladores con electrolitos alcalinos p ej celdas de litio debe seguir el est ndar EN 62133 1 2 No deben desmon
27. be plugged in the same way as on the main backplane In this way the addressing range of the CAN bus is expanded to slot codes 0000 slot A1 and 0001 slot A2 If the optional R amp S TS PXB2 backplane extension is used in the R amp S PowerTSVP TS PWA3 the R amp S TS PXB2 must be configured as a new device to prevent addressing collisions with slots 1 and 2 3 3 8 Switching the PSU Signal PS ON is used to power the PSU outputs on and off Jumper 3 is removed for this purpose see jumper field in Section 8 and replaced by an external switch Signal PS ON is available at the extension con nector X80 3 3 9 Line Inlet and Power Switch The line inlet and power switch are at the back of the R amp S PowerTSVP see Figure 3 3 9th Issue 09 11 amp SCHWARZ Test System Versatile Platform R amp S PowerTSVP TS PWA3 Description 3 3 10 Cooling The R amp S PowerTSVP possesses a powerful cooling concept The slots at the front optional in the Rear I O area are cooled by a vertical flow of air The four fans are above the slots and are connected to the back plane by series contact connectors see Figure 3 15 The fan speed is controlled by the internal temperature For the rear I O area fans can be retrofitted through the R amp S TS RFAN option The supply voltage for this fan unit is tapped at the 12 V studs refer to Figure 3 10 and earth sheet metal flashing The R amp S TS RFAN fan unit is especially required i
28. bus into part buses depends on the plug in mod ules which are used and the application that is to be implemented The analog bus concept of the R amp S PowerTSVP corresponds to the most reqirements of the measurement technology A small number of buses for a large number of I O channels e g In Circuit Test with 3 to 6 buses e As many signals as possible simultaneously for a moderate number of I O channels e g function test with 8 buses of 50 to 100 I O channels Parallel test with split analog bus Line paths or higher frequency signals are usually connected locally by special switching modules and not via the analog bus 3 3 3 2 2 Typical Use of the Analog Bus The use of the analog bus and individual bus lines is illustrated with available R amp S modules and standard modules see Figure 3 12 Internal Access to Analog Bus or Switching X22 Analog Bus Connector rear for Monitoring to Analog Bus for External Instruments External Instruments Modular Switching Modules UUT Figure 3 12 Use of the Analog Bus in the R amp S PowerTSVP Example 3 15 ROHDE amp SCHWARZ Description 3 16 Test System Versatile Platform R amp S PowerTSVP TS PWA3 3 3 3 3 Power Backplane The use of a second cPCI PSU in slots A1 A2 requires the optional Power Backplane conforms to standard PICMG 2 0 From the power backplane a cable with three connectors leads to a 2
29. must supplement the operating instructions with national ac cident prevention and environmental protection regulations as appro priate ROHDE amp SCHWARZ User Information 1 4 Test System Versatile Plattorm R amp S PowerTSVP TS PWA3 1 4 Explanation of Symbols The Test System Versatile Platform R amp S PowerTSVP has been ufactured in accordance with accepted engineering practice and the latest scientific and technical findings Nevertheless there are certain risks which cannot be designed out of equipment Additional safety instructions have been developed to provide ade quate safety for the personnel working on the R amp S PowerTSVP A satisfactory level of safety when using the R amp S PowerTSVP cannot be guaranteed unless these instructions are followed Certain sections of text are specially highlighted These sections have the following meaning DANGER Failure to follow instructions can result in personal injury ELECTROCUTION HAZARD Failure to follow instructions can result in personal injury WARNING Failure to following instructions can cause damage to the Test System Versatile Platform R amp S PowerTSVP DER CAUTION Failure to follow instructions can result in incorrect measure ments NOTE Highlights important details to which special attention must be paid and that make work easier 9th Issue 09 11 9th Issue 09 11 ROHDE amp S
30. of the R amp S PowerTSVP The configuration of the R amp S PowerTSVP is shown in Figure 3 1 ROHDE amp SCHWARZ Test System Versatile Platform 4 5 6 7 8 9 10141 1121131141415 16 PowerTSVP B Bus Slot 1 2 4 1 LI 3 1 with option TS PXB2 2 with option TS PCPA Figure 3 1 Configuration of the R amp S PowerTSVP ROHDE amp SCHWARZ Description Test System Versatile Platform R amp S PowerTSVP TS PWA3 Table 3 1 summarizes some further characteristics of the R amp S Pow erTSVP that are important for a Test System Versatile Platform Other Characteristics R amp S PowerTSVP Powerful cPCI PSU for 250 W expandable to 500 W Controlled by CAN Bus The internal analog bus makes it possible to distribute measure ment stimuli signals among the plug in modules with no additional cabling work Optional Front mounted adapter interface on the R amp S Pow erTSVP that uses spring contacts to facilitate rapid and high pole contacting with the UUTs see Figure 3 4 System serviceability is monitored by a built in self test capability and system monitor operating voltages temperature Table 3 1 Other Characteristics R amp S PowerTSVP 9th Issue 09 11 9th Issue 09 11 ROHDE
31. online de Phone 49 61 82 800 0 Fax 49 61 82 800 100 info hameg de Locations Worldwide Please refer to our homepage www rohde schwarz com Sales Locations Service Locations National Websites Customer Support Technical support where and when you need it For quick expert help with any Rohde 8 Schwarz equipment contact one of our Customer Support Centers A team of highly qualified engineers provides telephone support and will work with you to find a solution to your query on any aspect of the operation programming or applications of Rohde amp Schwarz equipment Up to date information and upgrades To keep your instrument up to date and to be informed about new application notes related to your instrument please send an e mail to the Customer Support Center stating your instrument and your wish We will take care that you will get the right information Europe Africa Middle East Phone 49 89 4129 12345 customersupport rohde schwarz com North America Phone 1 888 TEST RSA 1 888 837 8772 customer support rsa rohde schwarz com Latin America Phone 1 410 910 7988 customersupport la rohde schwarz com Asia Pacific Phone 65 65 13 04 88 customersupport asia rohde schwarz com China Phone 86 800 810 8228 86 400 650 5896 customersupport china rohde schwarz com ROHDE amp SCHWARZ 1171 0200 22 06 00 9th Issue 09 11 ROHDE amp SCHWARZ Test System Versatile Platform R amp S PowerTSVP TS
32. prevent personal injury e g due to laser beams 1171 0000 42 05 00 Page 4 Basic Safety Instructions Repair and service 1 The product may be opened only by authorized specially trained personnel Before any work 15 performed on the product or before the product is opened it must be disconnected from the AC supply network Otherwise personnel will be exposed to the risk of an electric shock Adjustments replacement of parts maintenance and repair may be performed only by electrical experts authorized by Rohde amp Schwarz Only original parts may be used for replacing parts relevant to safety e g power switches power transformers fuses A safety test must always be performed after parts relevant to safety have been replaced visual inspection PE conductor test insulation resistance measurement leakage current measurement functional test This helps ensure the continued safety of the product Batteries and rechargeable batteries cells If the information regarding batteries and rechargeable batteries cells is not observed either at all or to the extent necessary product users may be exposed to the risk of explosions fire and or serious personal injury and in some cases death Batteries and rechargeable batteries with alkaline electrolytes e g lithium cells must be handled in accordance with the EN 62133 standard 1 Cells must not be taken apart or crushed 2 Cells or batteries must not be exposed to heat or fir
33. r o Location Spidrova 49 CZ 38501 Vimperk ROHDE amp SCHWARZ GmbH amp Co KG Dienstleistungszentrum K ln Graf Zeppelin Stra e 18 D 51147 K ln P 0 Box 98 02 60 D 51130 K ln Subsidiaries R amp S BICK Mobilfunk GmbH Fritz Hahne Str 7 D 31848 Bad M nder P 0 Box 20 02 D 31844 Bad M nder ROHDE amp SCHWARZ FTK GmbH Wendenschlo stra e 168 Haus 28 D 12557 Berlin ROHDE amp SCHWARZ SIT GmbH Am Studio 3 D 12489 Berlin R amp S Systems GmbH Graf Zeppelin Stra e 18 D 51147 K ln GEDIS GmbH Sophienblatt 100 D 24114 Kiel HAMEG Instruments GmbH IndustriestraRe 6 D 63533 Mainhausen 1171 0200 42 02 00 Phone 49 89 41 29 0 Fax 49 89 41 29 121 64 info rs rohde schwarz com Phone 49 83 31 1 08 0 49 83 31 1 08 1124 info rsmb rohde schwarz com Phone 49 99 23 8 50 0 Fax 49 99 23 8 50 174 info rsdts rohde schwarz com Phone 420 388 45 21 09 Fax 420 388 45 21 13 Phone 49 22 03 49 0 Fax 49 22 03 49 51 229 info rsdc rohde schwarz com service rsdc rohde schwarz com Phone 49 50 42 9 98 0 Fax 49 50 42 9 98 105 info bick rohde schwarz com Phone 49 30 658 91 122 Fax 49 30 655 50 221 info ftk rohde schwarz com Phone 49 30 658 84 0 Fax 49 30 658 84 183 info sit rohde schwarz com Phone 49 22 03 49 5 23 25 Fax 49 22 03 49 5 23 36 info rssys rohde schwarz com Phone 49 431 600 51 0 Fax 49 431 600 51 11 sales gedis
34. related product documentation and the related product The use of tags in connection with unrelated products or documentation can result in misinterpretation and in personal injury or material damage Operating states and operating positions The product may be operated only under the operating conditions and in the positions specified by the manufacturer without the product s ventilation being obstructed Ifthe manufacturer s specifications are not observed this can result in electric shock fire and or serious personal injury or death Applicable local or national safety regulations and rules for the prevention of accidents must be observed in all work performed 1 Unless otherwise specified the following requirements apply to Rohde amp Schwarz products predefined operating position is always with the housing floor facing down IP protection 2X pollution severity 2 overvoltage category 2 use only indoors max operating altitude 2000 m above sea level max transport altitude 4500 m above sea level A tolerance of 10 shall apply to the nominal voltage and 5 to the nominal frequency N Do not place the product on surfaces vehicles cabinets or tables that for reasons of weight or stability are unsuitable for this purpose Always follow the manufacturer s installation instructions when installing the product and fastening it to objects or structures e g walls and shelves An installation that is not carried out as described in t
35. the back for this purpose see Figure 4 1 and Figure 4 3 This concept ensures a high degree of clarity rapid adaption to differ ent test tasks and allows the simple replacement of plug in modules 4 5 5 Opening the Case ELECTROCUTION HAZARD case of the Test System Versatile Platform R amp S Pow erTSVP should only be opened by qualified engineers Before opening the case the R amp S PowerTSVP must pow ered off and isolated from the power supply WARNING The ESD electrostatically sensitive device regulations must be complied with when opening the case of the R amp S PowerTSVP 4 10 9th Issue 09 11 9th Issue 09 11 ROHDE amp SCHWARZ Test System Versatile Plattorm R amp S PowerTSVP TS PWA3 Commissioning a x x2 ANALOG A 2 2 Figure 4 4 R amp S PowerTSVP Rear View 1 Case body 2 Rear case feet 4 The case of the R amp S PowerTSVP must be opened for internal cabling purposes To do this proceed as follows 1 Disconnect all connections at the front and rear of the R amp S Pow erTSVP 2 Unscrew the four feet at the back of the R amp S PowerTSVP 3 Setthe R amp S PowerTSVP on its front handles and carefully pull down the case body from the R amp S PowerTSVP The R amp S PowerTSVP is now accessible from all sides The case is closed in reverse order of opening 4 11 ROHDE amp SCHWARZ Commissioning 4 12 T
36. 4 pin ATX con nector on the control backplane The three connectors are as follows see also Section 8 Interface Description e X12 20 pin e X13 10 pin e X16 4 pin The second PSU can be used to boost the power of the standard PSU when connected in parallel Alternatively it can be used to supply the device on test 3 3 3 4 Backplane Extension R amp S TS PXB2 Option The R amp S TS PXB2 option expands the Test System Versatile Platform R amp S PowerTSVP by 2 CAN bus slots A1 and A2 It can be integrated ex works only The two slots are intended for the R amp S TS PIO3B or R amp S TS PTR op tions The R amp S TS PIO3B is an 8 channel 8 bit Open Collector Digital card with additional functions The R amp S TS PTR is a passive feedthrough circuit board It can be used to feed as many as 24 signals through the device Ports 5 6 and 7 of the R amp S TS PIO3B in slot A1 are routed to connec tor X1 on the rear panel Ports 5 7 of the R amp S TS PIO3B in slot A2 are available on connector DIO on the rear I O slot A4 In addition the system CAN bus is available at the CAN connector on the rear I O slot A4 The option R amp S TS PXB2 cannot be used together with the power backplane The jumpers and the assignment of the connectors in the rear I O area are described in chapter 8 6 9th Issue 09 11 9th Issue 09 11 Test System Versatile Platform R amp S PowerTSVP TS PWA3 ROHDE amp SCHWARZ 3 3 4 Ground Concept
37. 9th Issue 09 11 ROHDE amp SCHWARZ Test System Versatile Platform R amp S PowerTSVP TS PWA3 Description ROHDE amp SCHWARZ Test System Versatile Platform PowerTSVP AAA 5 619 PowerSuppy A FER EE RE ppm INESIS E T dT ro 1525072302 Rear side TS PSYS2 Option TS PDC 1 TS PAC TS PCAL2 TS PRIO TS PRIO4 TS PDC all Versions Frame numbering limited to 1 TS PWA3 frame no restriction with Version 21 Ser 2 100325 Module solder side must be isolated against the front panel in the left neighbor slot 2 3 only with optional backplane extension TS PXB2 Cannot be combined with power backplane TS PCPA 4 only with optional power backplane TS PCPA Cannot be combined with backplane extension TS PXB2 Figure 3 18 Module Configuration TS PWA3 3 33 ROHDE amp SCHWARZ Description 3 34 Test System Versatile Platform R amp S PowerTSVP TS PWA3 9th Issue 09 11 ROHDE amp SCHWARZ Test System Versatile Platform R amp S PowerTSVP TS PWA3 Commissioning 4 Commissioning 4 1 Safety Instructions When commissioning the R amp S PowerTSVP the safety instructions in Section 2 m
38. CHWARZ Test System Versatile Platform R amp S PowerTSVP TS PWA3 Safety 2 Safety 2 1 General The Test System Versatile Platform must be operated in accordance with the safety regulations which apply in the owner s country NOTE Safety risks created by an application that is based on the Test System Versatile Platform must be eliminated by suitable addi tional arrangements e g integration in the Emergency Stop cir cuit NOTE Failure to observe the safety regulations governing the opera tion of the Test System Versatile Platform shall void any liability or guarantee claims against ROHDE amp SCHWARZ GmbH amp Co KG 2 2 Safety Instructions ELECTROCUTION HAZARD The Test System Versatile Platform may only be opened by suit ably trained technical personnel The appropriate regulations governing work carried out on electrical equipment must be complied with The R amp S PowerTSVP must be isolated from the electrical supply be fore work commences WARNING Never link out defective fuses Always replace defective fuses with fuses of the same rating The electrical equipment fitted to the R amp S PowerTSVP must be checked at regular intervals Defects such as loose connections scorched cables etc must be rectified immediately The enclosed safety sheet must be complied with 2 1 ROHDE amp SCHWARZ Safety Test System Versatile Platform R amp S PowerTSVP TS
39. Number w Device Number x Slot Number Board Number and Controller Number are always 0 The Device Number of the frame is determined by the settings of the jumpers on the backplane see Section 3 3 7 For Rear l O modules like R amp S TS PSYS1 and R amp S TS PSYS2 a 4 has to be added to the Device Number 3 19 ROHDE amp SCHWARZ Description Test System Versatile Plattorm R amp S PowerTSVP TS PWA3 Example CANO 0 5 15 Board Number 0 Controller Number 0 Device Number 5 Device 1 Rear l O Slot Number 15 The following table shows the jumper configuration for the bus termina tions CAN1 System und CAN2 User Modul CAN Bus offen terminiert TS PCA3 System Jumper J3 and Jumper J3 and Jumper J4 Jumper J4 open geschlossen TS PWA3 System Jumper J4 and Jumper J4 and Jumper J5 Jumper J5 open closed 3 20 R amp S TS PSYS1 R amp S TS PSYS2 System Jumper JP6 open Jumper JP6 closed R amp S TS PSYS1 R amp S TS PSYS2 2 User Jumper JP7 open Jumper JP7 closed Table 3 5 CAN Bus Termination 9th Issue 09 11 9th Issue 09 11 ROHDE amp SCHWARZ Test System Versatile Platform R amp S PowerTSVP TS PWA3 Description 3 3 7 Configurations with several Frames or Option R amp S TS PXB2 In the following figure the terminating resistors are depicted in yellow CompactTSVP TS PSYS1 p LL Sul PowerTS
40. PWA3 9th Issue 09 11 9th Issue 09 11 Test System Versatile Platform R amp S PowerTSVP TS PWA3 ROHDE amp SCHWARZ 3 Description 3 1 Usage 3 1 1 General The Test System Versatile Platform TSVP is a standardized modular platform for the program controlled testing of modules and terminals in the factory or laboratory With its flexible configuration and the use of worldwide standards it can be perfectly adapted to suitthe needs ofthe user The R amp S PowerTSVP is primarily intended as a flexible switching unit for measurement signals signal sources and UUT loads This facili tates the migration of existing and proprietary Rack and Stack sys tems to a production test platform R amp S CompactTSVP TS PCA3 and R amp S PowerTSVP TS PWA3 can be combined to create more complex ATE Automatic Test Equipment systems with a high number of test pins The R amp S PowerTSVP is con trolled either by the system controller of a R amp S CompactTSVP cPCI system or by an external PC A serial bus system CAN Bus is used to trigger the modules in the R amp S PowerTSVP External cabling is used to make the connection with the measurement and trigger bus of the R amp S CompactTSVP The R amp S PowerTSVP can be fitted with special ROHDE amp SCHWARZ switching and load modules The unit provides an analog bus that can be used to make complex connections The modules can also be used without any modification in the R amp S CompactTSVP U
41. Position of Interfaces 8 3 2 Power Backplane Utility Connector X13 8 3 3 Power Backplane ATX Connector X12 8 3 4 Power Backplane Connector X16 8 3 5 Power Backplane Connector X1 P47 8 4 Interfaces of the R amp S TS PSYS2 8 4 1 R amp S TS PSYS2 Connector X20 8 4 2 R amp S TS PSYS2 Connector X30 8 4 3 R amp S TS PSYS2 Jumper Field X40 8 4 4 R amp S TS PSYS2 Jumper JP2 8 4 5 R amp S TS PSYS2 Jumper JP6 and JP7 8 4 6 R amp S TS PSYS2 Jumper JP8 8 5 External Analog Interface 8 5 1 Analog Bus Connector X2 ROHDE amp SCHWARZ Contents 6 1 6 1 6 1 6 2 7 1 7 1 7 3 8 1 8 1 8 1 8 3 8 4 8 6 8 6 8 7 8 7 8 8 8 8 8 9 8 10 8 11 8 12 8 12 8 12 8 13 8 13 8 14 8 16 8 16 8 17 8 18 8 18 8 18 8 19 8 20 8 20 ROHDE amp SCHWARZ Contents 9 8 6 Backplane Extension R amp S TS PXB2 Option 8 6 1 8 6 2 8 6 3 8 6 4 Technical Data Test System Versatile Platform R amp S PowerTSVP TS PWA3 Jumpers Rear panel slot A4 CAN Rear Panel Slot A4 DIO of Slot A2 Rear Panel X1 of Slot A1 8 21 8 21 8 21 8 22 8 23 9 1 9th Issue 09 11 9th Issue 09 11 ROHDE amp SCHWARZ Test System Versatile Platform R amp S PowerTSVP TS PWA3 Figures Figure 3 1 Configuration of the R amp S 3 3 Figure 3 2 uiu cocina A T 3 5 Figure 3 3 Liza e 3 5 Figure 3 4 Adapter Interface m
42. R amp S PowerTSVP TS PWA3 1 2 Related Documentation Comprehensive documentation is supplied to enable you to use the Test System Versatile Plattorm R amp S PowerTSVP efficiently The oper ating manual comprises the following sections e User Information e Safety e Description e Commissioning Operation Maintenance e Plug In Modules Interface description Technical Data The Appendices contain Declaration of Conformity NOTE In the event of any discrepancies between data in this manual and the technical data in the data sheet the data sheet takes prece dence 9th Issue 09 11 9th Issue 09 11 ROHDE amp SCHWARZ Test System Versatile Platform R amp S PowerTSVP TS PWA3 Userinformation 1 3 Purpose of the User Manual This User Manual provides the information that is necessary for commissioning and the proper and safe operation of the Test System Versatile Platform R amp S PowerTSVP This User Manual must be carefully read by the operator engineer who is responsible for working with the R amp S PowerTSVP before it is pow ered up for the first time As well as the operating instructions and the health and safety instruc tions which apply at the site where the system is used the applicable technical standards and regulations for safe and proper working must be complied with The operating instructions must be available at or near the R amp S Pow erTSVP at all times The owner
43. ROHDE amp SCHWARZ USER MANUAL Test Versatile Platform R amp S PowerTSVP TS PWA3 User Manual for ROHDE 8 SCHWARZ Test System Versatile Platform R amp S PowerTSVP 9th Issue 09 11 1157 8143 12 All rights also translation into foreign languages are reserved No part of this manual is permitted to be reproduced in any form print photocopy or any other method also not for the preparation of lectures or processed reproduced or made available using electronic systems without written permission from ROHDE 8 SCHWARZ The passing on to third parties and the reproduction of this documentation utilisation and com munication of its contents is not permitted unless specifically approved Infringements will incur claims for damages All rights reserved in the case of the award of a patent or registration of a design R amp S is a registered trademark of ROHDE amp SCHWARZ GmbH amp Co KG We draw to your attention that the names of software and hardware used in the Service Manual and the brand names of the respective companies are in general the subject of protection as trademarks or under proprietary rights or patent law ROHDE amp SCHWARZ GmbH amp Co KG Corporate Headquarters Telephone 49 0 89 4129 13774 M hldorfstr 15 Fax 49 0 89 4129 13777 D 81671 M nchen Printed in the Federal Republic of Germany Errors excepted subject to technical change without notice Basic
44. VP TS PWA3 TS PSYS2 Figure 3 14 Configuration example TS PCA3 und TS PWA3 CAN1 System is being connected between the two frames via cable R amp S 2 option The termination is carried out on both back planes The jumpers on the system modules R amp S TS PSYS1 and R amp S TS PSYS2 have to be left open According to Section 3 3 5 the jumpers for device addressing must be set as follows TS PCA3 J1 set Device 1 TS PWAS J1 set J2 not set Device 2 J1 GA4 42 GA5 Device set set 1 not set set 2 set not set 3 not set not set 4 Table 3 6 Device Addressing 3 21 ROHDE amp SCHWARZ Description 3 22 Test System Versatile Platform R amp S PowerTSVP TS PWA3 The optional R amp S TS PXB2 backplane extension also uses the CAN bus For the modules plugged there only R amp S TS PIO3B or R amp S TS PTR permitted GA4 and GAS can also be configured via jumpers For this reason the optional R amp S TS PXB2 backplane extension be haves like a complete device for the purpose of the CAN bus Table 3 7 is applicable to the optional R amp S TS PXB2 backplane exten sion X11 GA4 X10 GA5 Device set set 1 not set set 2 set not set 3 not set not set 4 Table 3 7 Device addressing for R amp S TS PXB2 If the optional R amp S TS PXB2 backplane extension is used in the R amp S CompactTSVP X10 GA5 can remain set and X11 GA4 can
45. XI R2 0 is also implemented The CAN bus 1 is integrated as the management bus and is availa ble at all slots Signals CAN L and CAN can be terminated with jumpers and resistors Figure 3 9 Instead of being terminated the bus can be extended externally using the extension connector X80 1 to standard 2 0b 1Mbit If the optional R amp S TS PXB2 backplane extension is used the CAN bus is also available at slots A1 and A2 The R amp S TS PXB2 is connect ed to the main backplane via X80 The use of the backplane extension does not change the termination principle CANH jue 3 5V lt 710 k 120 10 k GND Jumper 4 CAN L Figure 3 9 CAN Bus Termination 9th Issue 09 11 9th Issue 09 11 ROHDE amp SCHWARZ Test System Versatile Platform R amp S PowerTSVP TS PWA3 Number Pin max Lines VDC 2 5 CAN H P20 C1 CAN L P20 D1 Table 3 3 CAN Bus Description Two additional external signals e g supply voltages can be fed in via a plug in module in P20 This input can come from an internal AC DC module or from other external signal sources One way in which this feature can be used is to provide a primary voltage for generating local supply voltages DC DC converter Number Lines max VDC I _ Slot max ADC Pin 60 2 input for ext signals P20 AUX1 20 E19 P20 AUX2 A20 D19 Table 3 4 External
46. all assume no responsibility for such use of the product The product is used for its designated purpose if it is used in accordance with its product documentation and within its performance limits see data sheet documentation the following safety instructions Using the product requires technical skills and a basic knowledge of English It is therefore essential that only skilled and specialized staff or thoroughly trained personnel with the required skills be allowed to use the product personal safety gear is required for using Rohde 8 Schwarz products this will be indicated at the appropriate place in the product documentation Keep the basic safety instructions and the product documentation in a safe place and pass them on to the subsequent users Observing the safety instructions will help prevent personal injury or damage of any kind caused by dangerous situations Therefore carefully read through and adhere to the following safety instructions before and when using the product It is also absolutely essential to observe the additional safety instructions on personal safety for example that appear in relevant parts of the product documentation In these safety instructions the word product refers to all merchandise sold and distributed by the Rohde amp Schwarz group of companies including instruments systems and all accessories Symbols and safety labels 18 A A 4 Notice
47. amp Schwarz quality management system is certified according to standards such as ISO 9001 and ISO 14001 Environmental commitment 1 Energy efficient products 1 Continuous improvement in environmental sustainability 1150 14001 certified environmental management system Certified Quality System ISO 9001 Certified Environmental System ISO 14001 Cher client Vous avez choisi d acheter un pro duit Rohde amp Schwarz Vous disposez donc d un produit fabriqu d apr s les m thodes les plus avanc es Le d ve loppement la fabrication et les tests respectent nos normes de gestion qualit Le syst me de gestion qualit de Rohde amp Schwarz a t homologu entre autres conform ment aux nor mes ISO 9001 et ISO 14001 Engagement cologique 1 Produits efficience nerg tique 1 Am lioration continue de la durabilit environnementale 1 Syst me de gestion de l environne ment certifi selon ISO 14001 1171 0200 11 V 04 01 Address List Headquarters Plants and Subsidiaries Headquarters ROHDE amp SCHWARZ GmbH amp Co KG M hldorfstra amp e 15 D 81671 M nchen P 0 Box 80 14 69 D 81614 M nchen Plants ROHDE amp SCHWARZ Messger tebau GmbH Riedbachstra e 58 D 87700 Memmingen P 0 Box 16 52 D 87686 Memmingen ROHDE amp SCHWARZ GmbH amp Co KG Werk Teisnach Kaikenrieder Stra e 27 D 94244 Teisnach P 0 Box 11 49 D 94240 Teisnach ROHDE amp SCHWARZ z vod Vimperk s
48. amp S PowerTSVP CAN bus on the control backplane PXI Trigger bus on the control backplane Analog bus on separate backplane Internal cabling Cabling inside the case ofthe R amp S PowerTSVP Here plug in modules are connected with connectors used in the R amp S PowerTSVP case Cabling of the analog bus Cabling of ROHDE amp SCHWARZ modules to rear connectors or to each other External cabling Cabling outside the case Extended Compact TSVP ATE Module m Figure 4 3 Inner and Internal Cabling Variants 1 Analog bus 2 PXI Trigger Bus 3 Cabling of R amp S modules to rear connectors 9th Issue 09 11 9th Issue 09 11 ROHDE amp SCHWARZ Test System Versatile Platform R amp S PowerTSVP TS PWA3 Commissioning These various cabling options provide a number of benefits e Separating the adapter side front from the infeed of external de vices rear creates a clear signal concept with no cross wiring out side the case Wiring is kept safe from inadvertent changes simple inner cabling concept means that modules can be quickly replaced during servicing Bus connections are used in stead of cable connections System specific connectors e g D sub can be installed at the rear from where signals are connected to the analog bus or the adapter interface HF signals can also be carried in this way for example 4 5 2 Analog bus The analog bus is availa
49. ances that induce an allergic reaction allergens such as nickel cannot be generally excluded you develop an allergic reaction such as a skin rash frequent sneezing red eyes or respiratory difficulties when using Rohde amp Schwarz product consult a physician immediately to determine the cause and to prevent health problems or stress Before you start processing the product mechanically and or thermally or before you take it apart be sure to read and pay special attention to the section titled Waste disposal item 1 Depending on the function certain products such as RF radio equipment can produce an elevated level of electromagnetic radiation Considering that unborn babies require increased protection pregnant women must be protected by appropriate measures Persons with pacemakers may also be exposed to risks from electromagnetic radiation The employer operator must evaluate workplaces where there is a special risk of exposure to radiation and if necessary take measures to avert the potential danger Should a fire occur the product may release hazardous substances gases fluids etc that can cause health problems Therefore suitable measures must be taken e g protective masks and protective clothing must be worn If a laser product e g a CD DVD drive is integrated into a Rohde amp Schwarz product absolutely no other settings or functions may be used as described in the product documentation The objective 1 to
50. ara las personas No utilice el producto en condiciones en las que pueda producirse o ya se hayan producido condensaciones sobre el producto o en el interior de ste como p ej al desplazarlo de un lugar fr o a otro caliente La entrada de agua aumenta el riesgo de choque el ctrico Antes de la limpieza desconecte por completo el producto de la alimentaci n de tensi n p ej red de alimentaci n o bater a Realice la limpieza de los aparatos con un pa o suave que no se deshilache No utilice bajo ning n concepto productos de limpieza qu micos como alcohol acetona o diluyentes para lacas nitrocelul sicas Funcionamiento 1 2 3 4 El uso del producto requiere instrucciones especiales y una alta concentraci n durante el manejo Debe asegurarse que las personas que manejen el producto est n a la altura de los requerimientos necesarios en cuanto a aptitudes f sicas ps quicas y emocionales ya que de otra manera no se pueden excluir lesiones o da os de objetos El empresario u operador es responsable de seleccionar el personal usuario apto para el manejo del producto Antes de desplazar o transportar el producto lea y tenga en cuenta el cap tulo Transporte Como con todo producto de fabricaci n industrial no puede quedar excluida en general la posibilidad de que se produzcan alergias provocadas por algunos materiales empleados los llamados al rgenos ej el n quel Si durante el manejo de productos Rohde
51. aria indumentaria de seguridad para el uso de productos de Rohde amp Schwarz encontrar a la informaci n debida en la documentaci n del producto en el cap tulo correspondiente Guarde bien las informaciones de seguridad elementales as como la documentaci n del producto y entr guelas a usuarios posteriores Tener en cuenta las informaciones de seguridad sirve para evitar en lo posible lesiones o da os por peligros de toda clase Por eso es imprescindible leer detalladamente y comprender por completo las siguientes informaciones de seguridad antes de usar el producto y respetarlas durante el uso del producto Deber n tenerse en cuenta todas las dem s informaciones de seguridad como p ej las referentes a la protecci n de personas que encontrar n en el cap tulo correspondiente de la documentaci n del producto y que tambi n son de obligado cumplimiento En las presentes informaciones de seguridad se recogen todos los objetos que distribuye el grupo de empresas Rohde 8 Schwarz bajo la denominaci n de producto entre ellos tambi n aparatos instalaciones as como toda clase de accesorios S mbolos y definiciones de seguridad l Aviso punto de Atenci n en Peligro de Adver Conexi n a Conexi n Conexi n Aviso Cuidado peligro general el manejo de choque tencia conductor de a tierra amasa en el manejo de dispositivos el ctrico superficie protecci n dispositivos Observanla de peso caliente sen
52. ble at all slots of the R amp S PowerTSVP with its own backplane Switching modules can access the analog bus via con nectors X1 X16 at the various slots this is described in Section 3 Construction The following are available 8bus structured lines for user defined signal paths up to max 125 VDC 1 A between ROHDE amp SCHWARZ specific plug in mod ules NOTE Only the Rohde amp Schwarz plug in modules use the analog bus directly However external access to the analog bus is possible using R amp S switching modules or the analog bus connector at the back of the unit ROHDE amp SCHWARZ Commissioning Test System Versatile Platform R amp S PowerTSVP TS PWA3 4 5 3 PXI Trigger Bus Measurement and switching modules can be synchronized with the PXI trigger bus The external output of the signals is provided by the system module The following signals are available Trigger bus with 8 lines PXI TRIGO 7 4 5 4 External Cabling External cabling is used to connect measuring and stimuli devices as well as the UUT to the R amp S PowerTSVP Implementing the following concept should ensure the clarity of exter nal cabling design Cabling to the test devices should be at the front of the TSVP An adapter frame can be flange mounted here if required The cabling to measuring and stimuli devices is at the rear of the TSVP System and user specific terminals and plug and sock et connectors can be fitted in
53. caso de un accidente lesiones u otra clase de da os Eliminaci n 1 Si se trabaja de manera mec nica y o t rmica cualquier producto o componente m s all del funcionamiento previsto pueden liberarse sustancias peligrosas polvos con contenido de metales pesados como p ej plomo berilio o n quel Por eso el producto solo debe ser desmontado por personal especializado con formaci n adecuada Un desmontaje inadecuado puede ocasionar da os para la salud Se deben tener en cuenta las directivas nacionales referentes a la eliminaci n de residuos En caso de que durante el trato del producto se formen sustancias peligrosas o combustibles que deban tratarse como residuos especiales p ej refrigerantes o aceites de motor con intervalos de cambio definidos deben tenerse en cuenta las indicaciones de seguridad del fabricante de dichas sustancias y las normas regionales de eliminaci n de residuos Tenga en cuenta tambi n en caso necesario las indicaciones de seguridad especiales contenidas en la documentaci n del producto La eliminaci n incorrecta de sustancias peligrosas o combustibles puede causar da os a la salud o da os al medio ambiente 1171 0000 42 05 00 Page 12 Additional safety instructions Any alteration to the basic equipment is prohibited unless carried out by R amp S authorized persons In case that a module is inserted which is specified for an analog bus operation lt 60 VDC then this limit is also restrictive
54. e Storage in direct sunlight must be avoided Keep cells and batteries clean and dry Clean soiled connectors using a dry clean cloth 3 Cells or batteries must not be short circuited Cells or batteries must not be stored in a box or in a drawer where they can short circuit each other or where they can be short circuited by other conductive materials Cells and batteries must not be removed from their original packaging until they are ready to be used 4 Keep cells and batteries out of the hands of children If a cell or a battery has been swallowed seek medical aid immediately 5 Cells and batteries must not be exposed to any mechanical shocks that are stronger than permitted 6 Ifa cell develops a leak the fluid must not be allowed to come into contact with the skin or eyes If contact occurs wash the affected area with plenty of water and seek medical aid 7 Improperly replacing or charging cells or batteries that contain alkaline electrolytes e g lithium cells can cause explosions Replace cells or batteries only with the matching Rohde amp Schwarz type see parts list in order to ensure the safety of the product 8 Cells and batteries must be recycled and kept separate from residual waste Rechargeable batteries and normal batteries that contain lead mercury or cadmium are hazardous waste Observe the national regulations regarding waste disposal and recycling Transport 1 The product may be very heavy Therefore the produc
55. en reciclarse y no deben tirarse a la basura dom stica Las bater as o acumuladores que contienen plomo mercurio o cadmio deben tratarse como residuos especiales Respete en esta relaci n las normas nacionales de eliminaci n y reciclaje Transporte 1 El producto puede tener un peso elevado Por eso es necesario desplazarlo o transportarlo con precauci n y si es necesario usando un sistema de elevaci n adecuado p ej una carretilla elevadora a fin de evitar lesiones en la espalda u otros da os personales Las asas instaladas en los productos sirven solamente de ayuda para el transporte del producto por personas Por eso no est permitido utilizar las asas para la sujeci n en o sobre medios de transporte como p ej gr as carretillas elevadoras de horquilla carros etc Es responsabilidad suya fijar los productos de manera segura a los medios de transporte o elevaci n Para evitar da os personales o da os en el producto siga las instrucciones de seguridad del fabricante del medio de transporte o elevaci n utilizado Si se utiliza el producto dentro de un veh culo recae de manera exclusiva en el conductor la responsabilidad de conducir el veh culo de manera segura y adecuada El fabricante no asumir ninguna responsabilidad por accidentes o colisiones No utilice nunca el producto dentro de un veh culo en movimiento si esto pudiera distraer al conductor Asegure el producto dentro del veh culo debidamente para evitar en
56. enta que las palabras de se al aqu descritas sean utilizadas siempre solamente en combinaci n con la correspondiente documentaci n del producto y solamente en combinaci n con el producto correspondiente La utilizaci n de las palabras de se al en combinaci n con productos o documentaciones que no les correspondan puede llevar a interpretaciones equivocadas y tener por consecuencia da os en personas u objetos Estados operativos y posiciones de funcionamiento El producto solamente debe ser utilizado seg n lo indicado por el fabricante respecto a los estados operativos y posiciones de funcionamiento sin que se obstruya la ventilaci n Si no se siguen las indicaciones del fabricante pueden producirse choques el ctricos incendios y o lesiones graves con posible consecuencia de muerte En todos los trabajos deber n ser tenidas en cuenta las normas nacionales y locales de seguridad del trabajo y de prevenci n de accidentes 1 Si no se convino de otra manera es para los productos Rohde amp Schwarz v lido lo que sigue como posici n de funcionamiento se define por principio la posici n con el suelo de la caja para abajo modo de protecci n IP 2X grado de suciedad 2 categor a de sobrecarga el ctrica 2 uso solamente en estancias interiores utilizaci n hasta 2000 m sobre el nivel del mar transporte hasta 4500 m sobre el nivel del mar Se aplicar una tolerancia de 10 sobre el voltaje nominal y de 5 sobre la frecuencia nominal
57. est System Versatile Platform R amp S PowerTSVP TS PWA3 9th Issue 09 11 9th Issue 09 11 ROHDE amp SCHWARZ Test System Versatile Platform R amp S PowerTSVP TS PWA3 Operation 5 Operation 5 1 General The R amp S PowerTSVP does not have any controls all operation is per formed by the software HINWEIS Please refer to the appropriate documentation for details of soft ware operation 5 2 Self Test A system self test consists of self test of the R amp S PowerTSVP System self test including connections between the individual de vices e With rack mounting there is a self test of the built in devices whe re supplied GPIB devices PSU etc The system self test is expandable The self test can also be called by remote control HINWEIS The call of the system self test depends on the software that is used The DMM contacts the installed ROHDE amp SCHWARZ plug in modules in succession via the analog measuring bus In this way it is possible to test all connections and relay contacts for volume resistance and insu lation ROHDE amp SCHWARZ Operation Test System Versatile Platform R amp S PowerTSVP TS PWA3 9th Issue 09 11 9th Issue 09 11 ROHDE amp SCHWARZ Test System Versatile Platform R amp S PowerTSVP TS PWA3 Maintenance 6 Maintenance 6 1 Important User Information NOTE The Test System Versatile Platform R amp S PowerTSVP is mainte nance free DANGER Onl
58. f for lack of space slots cannot remain free between modules with DC DC converter module R amp S TS PDC in the rear lO area or the R amp S PowerTSVP is not operated in normal horizon tal standard position WARNING Adequate space for air inlet and outlet should be allowed when the case is rack mounted with at least half a height unit 22 mm being left above and below the chassis For desktop mounting ensure that the case is not covered over 9th Issue 09 11 3 23 ROHDE amp SCHWARZ Description 3 24 Test System Versatile Platform RES PowerTSVP TS PWA3 Figure 3 15 Layout of Fans in the Frame 9th Issue 09 11 9th Issue 09 11 ROHDE amp SCHWARZ Test System Versatile Platform R amp S PowerTSVP TS PWA3 3 4 System Module R amp S TS PSYS2 3 4 1 General Description The R amp S TS PSYS2 is in the Rear I O slot 15 of the R amp S PowerTSVP It acts primarily as a CAN Interface and therefore as an interface for communication with R amp S CAN modules in the R amp S CompactTSVP and R amp S PowerTSVP Additional system functions such as voltage and temperature monitor ing trigger signals and optocoupler interface are used to integrate the R amp S CompactTSVP and R amp S PowerTSVP in a complete system 3 4 2 Characteristics R amp S TS PSYS2 RTM type with cPCI inter
59. f the slot ROHDE amp SCHWARZ Interface description Test System Versatile Platform R amp S PowerTSVP TS PWA3 8 2 3 Analog Bus Connector X21 00000 0000902 Figure 8 9 Connector X21 Mating Side Table 8 9 Assignment of X21 8 10 Pin Signal Pin Signal 1 GND 2 GND 3 ABc1 4 ABa1 B ABc2 6 ABb1 7 ABa2 8 ABb2 9 ABd2 10 ABd1 9th Issue 09 11 9th Issue 09 11 Test System Versatile Platform R amp S PowerTSVP TS PWA3 8 2 4 Analog Bus Connector X22 Figure 8 10 Connector X22 Mating Side ROHDE amp SCHWARZ Interface description Table 8 10 Assignment of X22 Note IL1 5 111 of slot 5 Pin Signal Pin Signal 1 IL1 5 2 12 5 3 IL1 6 4 126 5 IL1 7 6 12 7 7 IL1 8 8 12 8 9 IL1 9 10 12 9 11 IL1 10 12 IL2 10 13 IL1 11 14 IL2 11 15 IL1 12 16 12 12 17 IL1 13 18 12 13 19 IL1 14 20 12 14 21 IL1 15 22 12 15 23 IL1 16 24 IL2 16 25 GND 26 GND 8 11 ROHDE amp SCHWARZ Interface description Test System Versatile Platform R amp S PowerTSVP TS PWA3 8 3 Power Backplane Option 8 3 1 Position of Interfaces Top View Figure 8 11 Power Backplane Made in Germany o a o E en gt Ss gt a a o a E lt gt g o Er lt Bottom View 8 3 2 Power Backplane
60. face 2 independent CAN interfaces 2 0 A B 1 Mb s System functions via CAN node microcontroller Voltage monitor Temperature measuring internal Enable of the PXI trigger signals to the exterior 4 optocoupler outputs 4 optocoupler inputs 2 switchable short circuit proof output voltages System identification Manual selection of the local or external system clock and its buffering with jumper Table 3 8 Characteristics of the R amp S TS PSYS2 3 25 ROHDE amp SCHWARZ Description Test System Versatile Platform R amp S PowerTSVP TS PWA3 3 26 3 4 3 Circuit Diagram of the R amp S TS PSYS2 Figure 3 16 shows the circuit diagram of the R amp S TS PSYS2 JP8 CLK10 OUT CLK10 IN e J SYNC OUT 6 AUX PXI_CLK10 DC_SYNC PhotoMos Output Optocoupler Input 3 3 5V 12 12V Rear 1 0 X20 Voltage PXI_TRIG 8 Front Connector X30 CAN2 User Figure 3 16 Circuit Diagram of the R amp S TS PSYS2 3 4 4 Structure of the R amp S TS PSYS2 The R amp S TS PSYS2 is the size of a standard cPCI RTM Rear Trans mission Module and is mounted in slot 15 atthe rear ofthe TSVP chas sis 9th Issue 09 11 9th Issue 09 11 Test System Versatile Platform R amp S PowerTSVP TS PWA3 ROHDE amp SCHWARZ Description Connector X20 is used to make the connections to
61. he product documentation could result in personal injury or death eo Do not place the product on heat generating devices such as radiators or fan heaters The ambient temperature must not exceed the maximum temperature specified in the product documentation or in the data sheet Product overheating can cause electric shock fire and or serious personal injury or death 1171 0000 42 05 00 Page 2 Basic Safety Instructions Electrical safety If the information on electrical safety is not observed either at all to the extent necessary electric shock fire and or serious personal injury or death may occur 1 Prior to switching on the product always ensure that the nominal voltage setting on the product matches the nominal voltage of the AC supply network If a different voltage 1 to be set the power fuse of the product may have to be changed accordingly 2 In the case of products of safety class with movable power cord and connector operation is permitted only on sockets with an earthing contact and protective earth connection 3 Intentionally breaking the protective earth connection either in the feed line or in the product itself is not permitted Doing so can result in the danger of an electric shock from the product If extension cords or connector strips are implemented they must be checked on a regular basis to ensure that they are safe to use 4 If the product does not have a power switch for disconnection from the AC sup
62. ity 3 AUXA 6 15A 3 6 1 3 1 5 2 CAN2 9th Issue 09 11 9th Issue 09 11 ROHDE amp SCHWARZ Test System Versatile Platform R amp S PowerTSVP TS PWA3 Description 3 4 6 Driver Software The R amp S TS PSYS2 is triggered by a universal driver software The lo cal microcontroller is triggered by the CAN1 bus and the R amp S specific protocol The following software modules are installed during driver installation RSCAN e RSPSYS 3 4 7 Self Test The R amp S TS PSYS2 has no built in self test capability The function of the internal CAN bus can be checked with the local CAN node 3 5 Function Description The functionality of the R amp S PowerTSVP depends essentially on the in stalled plug in modules and the related software The R amp S PowerTSVP is basically suitable for all types of production tests An adapter interface can be flange mounted on the front of the R amp S PowerTSVP for the rapid and high pole adaption of UUTs see Figure 3 4 3 31 ROHDE amp SCHWARZ Description 3 32 Test System Versatile Platform R amp S PowerTSVP TS PWA3 3 6 Permitted Module Configurations Because of the different properties of plug in modules for example control bus power supply rear I O module required controller function power pack there are restrictions on the use of plug in slots Figure 3 18 shows an overview of which modules can be operated in which plug in slots 9th Issue 09 11
63. ly valid for the total system The voltage limits for exposed voltage carrying parts under DIN EN61010 1 6 3 must on no account be exceeded If the use of higher voltages is required this may be done only after consultation with R amp S The total power which may be drawn from the secondary side depends on the format of the relevant backplane segment typically 250VA When installing in racks the ventilation of the system must be such that the specified data sheet values of 0 50 C are adhered to Qualitatszertifikat Certificate of quality Certificat de qualit Sehr geehrter Kunde Sie haben sich f r den Kauf eines Rohde 8 Schwarz Produktes ent schieden Hiermit erhalten Sie ein nach modernsten Fertigungsmethoden hergestelltes Produkt Es wurde nach den Regeln unseres Qualit tsmanage mentsystems entwickelt gefertigt und gepr ft Das Rohde amp Schwarz Qualit tsmanagementsystem ist u a nach ISO 9001 und ISO 14001 zertifiziert Der Umwelt verpflichtet Energie effiziente RoHS konforme Produkte Kontinuierliche Weiterentwicklung nachhaltiger Umweltkonzepte 1 ISO 14001 zertifiziertes Umweltmanagementsystem Dear Customer You have decided to buy a Rohde amp Schwarz product You are thus assured of receiving a product that is manufactured using the most modern methods available This product was developed manufactured and tested in compliance with our quality management system stan dards The Rohde
64. mp S PowerTSVP see Section 4 4 2 The electrical characteristics of the analog lines are e Voltage 125 VDC max Current 1 3 13 ROHDE amp SCHWARZ Description Test System Versatile Platform R amp S PowerTSVP TS PWA3 3 14 3 3 3 2 1 Concept of the Analog Bus do B amp amp an udis D PR T Analogbus Instrument Pins UUT Pins O Channels Figure 3 11 Principle of the Analog Bus The analog bus in the R amp S PowerTSVP connects I O channels of dif ferent plug in modules to each other under program control I O chan nels may be connections of instruments measuring and stimuli devic es and connections of the device on test Up to 8 different signals can be connected simultaneously see Figure 3 11 The analog bus can be used flexibly with the ROHDE amp SCHWARZ specific plug in modules 8 equivalent lines are basically available ABa1 ABa2 ABb1 ABb2 ABc1 ABc2 ABd1 ABd2 External instru ments are usually connected to the R amp S PowerTSVP with a rear I O connection The signals for the UUT are made available at the front end connector of the various plug in modules on the R amp S PowerTSVP The analog bus can be used in different ways e as bus with 8 lines e in2 part buses with 4 lines each 9th Issue 09 11 9th Issue 09 11 ROHDE amp SCHWARZ Test System Versatile Platform R amp S PowerTSVP TS PWA3 Description The split of the analog
65. mperature to voltage converter is used as the sen sor The temperature proportional analog voltage is also output at con nector X30 for monitoring purposes TEMP OUT 3 4 5 2 7 Geographical Addressing According to the cPCI specification each slot is assigned its own digital slot code GA code This code is used internally to directly address the uC 3 4 5 3 System Clock A local quartz crystal generates the 10 MHz system pulse for the PXI system CLK10 Alternatively a very accurate reference pulse can be fed in across X30 Jumper JP2 is used to select an internal or exter nal clock source The jumper functions are shown in Section 8 4 Description 3 29 ROHDE amp SCHWARZ Description Test System Versatile Plattorm R amp S PowerTSVP TS PWA3 3 4 5 4 Signal Looping A number of signal lines are looped from connector X30 to connector X20 These are used to input output Rear I O signals e g for the R amp S switching modules R amp S TS PMB R amp S TS PSAM Number Signal Name Current Carrying Capacity Lines 2 AUXA 2 3A 4 AUX3 6 1 5A 3 4 5 5 Local Signal Outputs Special signals of the Power TSVP can be connected to connector X20 Rear I O with the help of jumper field X40 The jumper functions are described in Section 8 4 WARNING Jumpers only permitted when system voltages are 60 VDC 3 30 Number Signal Name Current Carrying Lines Capac
66. munity Contact springs are mounted between the individual front sub panels for this purpose The case is suitable for 3U high plug in boards The remaining space in the case can be used for adaption to the standard UUT connector or for concealed cross cabling Table 3 2 Features of the BW 2000 Case 3 7 ROHDE amp SCHWARZ Description Test System Versatile Platform R amp S PowerTSVP TS PWA3 3 3 2 Slot Layout 3 3 2 1 Plan View Optional CPCI Power Supply P47 or up to 2 TS PIO3B TS PTR CPCI Power Supply P47 Optional Power Backplane Or AC Backplane Extension Mains TS PXB2 input R amp S CAN Module Control Module R amp S CAN Module Load Module Analogbus Backplane R amp S CAN Module Wire R amp S CAN Module VO Module R amp S CAN Module R amp S CAN Module Load Module R amp S CAN Module R amp S Matrix Module Rear I O R amp S Matrix Module R amp S Matrix Module R amp S Matrix Module R amp S Matrix Module System Module PSYS2 R amp S Matrix Module Figure 3 6 Plan View example 9th Issue 09 11 9th Issue 09 11 ROHDE amp SCHWARZ Test System Versatile Platform R amp S PowerTSVP TS PWA3 Description 3 3 2 2 Side View Control Backplane Figure 3 7 Side View
67. nnectors Erni and Pan duit connectors only NOTE With adapters you should remember that the count sequence on connector P20 at the back of the control backplane is the mirror image of the front NOTE The plug in modules used in the R amp S PowerTSVP are described in separate documents 9th Issue 09 11 9th Issue 09 11 Test System Versatile Platform R amp S PowerTSVP TS PWA3 ROHDE amp SCHWARZ 7 2 Configuration Instructions Care must be taken to observe EMC regulations Sufficient shield ing can only be achieved with sectional front plates and shield springs on the inner and outer fastening level The two levels can be connected with option R amp S TS PSK1 HF shield wall kit One slot is lost in this process If long cards are plugged in next to short ones care must be taken to ensure the sectional front plate of the short card cannot touch the lines of the adjacent module risk of short circuit To achieve even dissipation of heat modules with R amp S TS PDC should not be fitted immediately next to each other if possible This makes it easier to cool the R amp S TS PDCs which can become quite hot The optionally available rear I O fan unit R amp S TS RFAN provides for enhanced cooling of the R amp S TS PDC and is required especially when the installation position is not horizontal R amp S TS PSM1 should be connected to slot 16 so that signals from the power plug can be better directed to the back If an addi
68. onal supply voltages 4 5 V 11 5 V e 3x supply voltage measurement 1 measurement of the internal temperature 3 4 5 2 1 PXI Trigger The input output of trigger signals X20 is controlled separately for each signal On the output side the signals are terminated by pullup re sistors and protected by self healing fuses and d c clamp diodes The external trigger lines are available at connector X30 3 4 5 2 2 Floating Outputs 4 PhotoMos relays with internal current limiter are triggered by a port The signals are available at connector X30 9th Issue 09 11 9th Issue 09 11 Test System Versatile Platform R amp S PowerTSVP TS PWA3 ROHDE amp SCHWARZ 3 4 5 2 3 Floating Inputs A C port reads the status of 4 optocoupler inputs 2 x 2 pin The current at the inputs is limited so that inputs signals can be fed in unconditioned within a wide voltage range These inputs are available at connector X30 3 4 5 2 4 Output voltages Two voltage regulators with output enable control generate switchable short circuit proof voltages of 4 5 V and 11 5 V at X30 These voltag es can be used to supply external components e g signal lamps 3 4 5 2 5 Measuring the cPCI Supply Voltages The supply voltages present at connector X20 5 V 12 V 12 V are measured with the A D ports of the uC 3 4 5 2 6 Temperature Measurement An A D port of the C is used to measure the ambient temperature of the plug in module A te
69. ot connected 30 M V1SENSE V1 Remote Sense 31 M Reserved 3 32 N NC Not connected 33 M V2SENSE V2 Remote Sense 34 M SRTN Sense Return 35 VISHARE V1 Current Share Table 8 14 Assignment of X1 P47 8 14 9th Issue 09 11 9th Issue 09 11 ROHDE amp SCHWARZ Test System Versatile Platform R amp S PowerTSVP TS PWA3 Interface description Pin 1 Signal Name Description 36 M V3SENSE V3 Remote Sense 37 M Reserved 38 M DEG Degrade Signal 39 M INH Inhibit 40 Reserved 3 41 V2SHARE V2 Current Share 42 FAL Fail Signal 43 Reserved 3 44 M V3SHARE V3 Current Share 45 E CGND Chassis Ground 46 M CAN AC Input Neutral 47 M ACL AC Input Line Table 8 14 Assignment of X1 P47 1 Pin numbers illustrated are of the female backplane connector z L long length pins M medium length pins S short length pins 3 For future options 8 15 ROHDE amp SCHWARZ Interface description Test System Versatile Platform R amp S PowerTSVP TS PWA3 8 4 Interfaces of the R amp S TS PSYS2 8 4 1 R amp S TS PSYS2 Connector X20 OOOOOOO0 22 ZABCDEF Figure 8 13 R amp S TS PSYS2 Connector X20 Mating Side NC not connected NP not populated 22 Table 8 15 R amp S TS PSYS2 Assignment X20 8 16 C O C T O R 9th Issue 09 11 9th Issue 09 11 Test System Versatile Platform R amp S PowerTSVP TS PWA3 8 4 2 R amp S TS
70. p S TS PDC rear I O modules without spacing the use of the R amp S TS RFAN fan option is strongly recommended ROHDE amp SCHWARZ Commissioning Test System Versatile Platform R amp S PowerTSVP TS PWA3 4 3 Installation 4 3 1 Safety Instructions WARNING Comply with ESD Electrostatic Discharge regulations when fit ting plug in modules 4 3 2 Compatibility NOTE Only the ROHDE amp SCHWARZ specific modules with CAN bus triggering can be plugged into the R amp S PowerTSVP 4 3 3 Module Installation To install an R amp S plug in module proceed as follows Run down and power off the R amp S PowerTSVP Select a suitable slot see Section 4 3 2 Remove the appropriate front panel by slackening off the screws WARNING Check backplane connectors for bent pins Any bent pins must be straightened Failure to do this may permanently damage the backplane Pushin the plug in module using moderate pressure top snap pin on the module must locate in the right hand and the bottom pin in the left hand hole on the TSVP chassis WARNING Use both hands to guide the module and carefully plug it into the backplane connectors e module is correctly located when a distinct stop can be felt e Tighten the top and bottom screws on the front panel of the plug in module 9th Issue 09 11 9th Issue 09 11 ROHDE amp SCHWARZ Test System Ver
71. p to four R amp S PowerTSVP s can be cascaded The peripheral modules can be quickly and flexibly adapted to the UUTs by preceding the R amp S PowerTSVP with an adapter frame which connects the signals securely and with a low rate of wear Description 3 1 ROHDE amp SCHWARZ Description 3 2 Test System Versatile Platform R amp S PowerTSVP TS PWA3 3 1 2 Explanation of Terms The following terms and standards are used in this manual CompactPCI abbreviated to cPCI in this document is an open standard of the PICMG PCI Industrial Manufacturers Group that adapts the PCI standard for industrial applications It uses high grade connection techniques and mechanical components and applies the same electrical specifications as the PCI standard This makes it pos sible to use inexpensive components and existing PCI developments even under industrial conditions Other features include a high integra tion density the option of a 19 installation and shielding for the plug in modules Its definition as an open standard means that a large world wide variety of cards is available This standard is used in the R amp S CompactTSVP PXI PCI eXtensions for Instrumentation is a standard defined by Na tional Instruments which extends cPCI The R amp S PowerTSVP adopts the same mechanical specifications and the interfacing with the trigger system CAN Controller Area Network is a serial bus system whose high sys tem and configura
72. per disassembly may be hazardous to your health National waste disposal regulations must be observed 2 If handling the product releases hazardous substances or fuels that must be disposed of in a special way e g coolants or engine oils that must be replenished regularly the safety instructions of the manufacturer of the hazardous substances or fuels and the applicable regional waste disposal regulations must be observed Also observe the relevant safety instructions in the product documentation The improper disposal of hazardous substances or fuels can cause health problems and lead to environmental damage Informaciones elementales de seguridad Es imprescindible leer y observar las siguientes instrucciones e informaciones de seguridad El principio del grupo de empresas Rohde amp Schwarz consiste en tener nuestros productos siempre al d a con los est ndares de seguridad y de ofrecer a nuestros clientes el m ximo grado de seguridad Nuestros productos y todos los equipos adicionales son siempre fabricados y examinados seg n las normas de seguridad vigentes Nuestro sistema de garant a de calidad controla constantemente que sean cumplidas estas normas El presente producto ha sido fabricado y examinado seg n el certificado de conformidad adjunto de la UE y ha salido de nuestra planta en estado impecable seg n los est ndares t cnicos de seguridad Para poder preservar este estado y garantizar un funcionamiento libre de peligros el usua
73. ply network the plug of the connecting cable is regarded as the disconnecting device In such cases always ensure that the power plug is easily reachable and accessible at all times corresponding to the length of connecting cable approx 2 m Functional or electronic switches are not suitable for providing disconnection from the AC supply network If products without power switches are integrated into racks or systems a disconnecting device must be provided at the system level 5 Never use the product if the power cable is damaged Check the power cable on a regular basis to ensure that it is in proper operating condition By taking appropriate safety measures and carefully laying the power cable you can ensure that the cable will not be damaged and that no one can be hurt by for example tripping over the cable or suffering an electric shock 6 The product may be operated only from TN TT supply networks fused with max 16 A higher fuse only after consulting with the Rohde amp Schwarz group of companies 7 not insert the plug into sockets that are dusty or dirty Insert the plug firmly and all the way into the socket Otherwise sparks that result in fire and or injuries may occur 8 Do not overload any sockets extension cords or connector strips doing so can cause fire or electric shocks 9 For measurements in circuits with voltages V ms gt 30 V suitable measures e g appropriate measuring equipment fusing current limi
74. rio deber atenerse a todas las indicaciones informaciones de seguridad y notas de alerta El grupo de empresas Rohde amp Schwarz est siempre a su disposici n en caso de que tengan preguntas referentes a estas informaciones de seguridad Adem s queda en la responsabilidad del usuario utilizar el producto en la forma debida Este producto est destinado exclusivamente al uso en la industria y el laboratorio o si ha sido expresamente autorizado para aplicaciones de campo y de ninguna manera deber ser utilizado de modo que alguna persona cosa pueda sufrir da o El uso del producto fuera de sus fines definidos o sin tener en cuenta las instrucciones del fabricante queda en la responsabilidad del usuario El fabricante no se hace en ninguna forma responsable de consecuencias a causa del mal uso del producto 1171 0000 42 05 00 Page 6 Informaciones elementales de seguridad Se parte del uso correcto del producto para los fines definidos si el producto es utilizado conforme a las indicaciones de la correspondiente documentaci n del producto y dentro del margen de rendimiento definido ver hoja de datos documentaci n informaciones de seguridad que siguen El uso del producto hace necesarios conocimientos t cnicos y ciertos conocimientos del idioma ingl s Por eso se debe tener en cuenta que el producto solo pueda ser operado por personal especializado o personas instruidas en profundidad con las capacidades correspondientes Si fuera neces
75. satile Platform R amp S PowerTSVP TS PWA3 Commissioning Please observe the following instructions for installation of a Rear I O module e Rear I O modules for example R amp S TS PDC must be inserted with extra caution making certain the connector is correctly guided into the socket opening in the backplane It must not be inserted at an angle or with incorrect alignment etc The short circuit board guides alone do not ensure absolutely reliable guiding e Multiple adjacent R amp S TS PDC modules should be inserted in or der from left to right and removed in the opposite order Because the spaces are so narrow care must be taken not to damage any components on the solder side of the module 4 3 4 Driver Installation The drivers to be installed for the plug in modules will depend on the operating system and the module itself and you should therefore con sult the documentation supplied for the particular module ROHDE amp SCHWARZ Commissioning Test System Versatile Platform R amp S PowerTSVP TS PWA3 4 4 Connections 4 4 1 Line Inlet The R amp S PowerTSVP requires a supply with the range of 110 60 Hz or 230 Vic 50 Hz Fuse protection for the line inlet must not ex ceed a rating of 16 A The PSU used in the R amp S PowerTSVP has automatic voltage selec tion between 100 and 240 VAC see also Section 9 Technical Data 4 4 2 Connections at the Rear ANALOG 4 2 x1
76. sibles a la documentaci n elevado electrost tica del producto ESD iO o ca Tensi n de Indicaci n de Corriente Corriente alterna Corriente El aparato est protegido alimentaci n de estado de continua DC AC continua en su totalidad por un PUESTA EN espera Corriente alterna aislamiento doble MARCHA Standby DC AC reforzado PARADA 1171 0000 42 05 00 Page 7 Informaciones elementales de seguridad Palabras de se al y su significado En la documentaci n del producto se utilizan las siguientes palabras de se al con el fin de advertir contra riesgos y peligros PELIGRO identifica un peligro inminente con riesgo elevado que 4 PELIGRO provocar muerte o lesiones graves si no se evita ADVERTENCIA identifica un posible peligro con riesgo medio de ADVERTENCIA provocar muerte o lesiones graves si no se evita ATENCI N identifica un peligro con riesgo reducido de provocar ATENCI N lesiones leves o moderadas si se evita AVISO indica la posibilidad de utilizar mal el producto y como consecuencia da arlo En la documentaci n del producto se emplea de forma sin nima el t rmino CUIDADO Las palabras de se al corresponden a la definici n habitual para aplicaciones civiles en el rea econ mica europea Pueden existir definiciones diferentes a esta definici n en otras reas econ micas o en aplicaciones militares Por eso se deber tener en cu
77. t must be handled with care In some cases the user may require a suitable means of lifting or moving the product e g with a lift truck to avoid back or other physical injuries 1171 0000 42 05 00 Page 5 Informaciones elementales de seguridad 2 Handles on the products are designed exclusively to enable personnel to transport the product It is therefore not permissible to use handles to fasten the product to or on transport equipment such as cranes fork lifts wagons etc The user is responsible for securely fastening the products to or on the means of transport or lifting Observe the safety regulations of the manufacturer of the means of transport or lifting Noncompliance can result in personal injury or material damage 3 If you use the product in a vehicle it is the sole responsibility of the driver to drive the vehicle safely and properly The manufacturer assumes no responsibility for accidents or collisions Never use the product in a moving vehicle if doing so could distract the driver of the vehicle Adequately secure the product in the vehicle to prevent injuries or other damage in the event of an accident Waste disposal 1 If products or their components are mechanically and or thermally processed in a manner that goes beyond their intended use hazardous substances heavy metal dust such as lead beryllium nickel may be released For this reason the product may only be disassembled by specially trained personnel Impro
78. tarse abrirse ni triturarse las celdas Las celdas o bater as no deben someterse a calor ni fuego Debe evitarse el almacenamiento a la luz directa del sol Las celdas y bater as deben mantenerse limpias y secas Limpiar las conexiones sucias con un pa o seco y limpio Las celdas o bater as no deben cortocircuitarse Es peligroso almacenar las celdas o bater as en estuches o cajones en cuyo interior puedan cortocircuitarse por contacto rec proco o por contacto con otros materiales conductores No deben extraerse las celdas o bater as de sus embalajes originales hasta el momento en que vayan a utilizarse Mantener bater as y celdas fuera del alcance de los ni os En caso de ingesti n de una celda o bater a avisar inmediatamente a un m dico Las celdas o bater as no deben someterse a impactos mec nicos fuertes indebidos 1171 0000 42 05 00 Page 11 Informaciones elementales de seguridad 6 En caso de falta de estanqueidad de una celda el l quido vertido no debe entrar en contacto con la piel ni los ojos Si se produce contacto lavar con agua abundante la zona afectada y avisar a un m dico En caso de cambio o recarga inadecuados las celdas o bater as que contienen electrolitos alcalinos p ej las celdas de litio pueden explotar Para garantizar la seguridad del producto las celdas o bater as solo deben ser sustituidas por el tipo Rohde 8 Schwarz correspondiente ver lista de recambios Las bater as y celdas deb
79. the R amp S TS PSYS2 Jumper 8 8 19 Analog Bus Connector X2 Mating Side 8 20 9th Issue 09 11 ROHDE amp SCHWARZ 9th Issue 09 11 Test System Versatile Platform R amp S PowerTSVP TS PWA3 Tables Tables Table 3 1 Other Characteristics R amp S PowerTSVP 3 4 Table 3 2 Features of the BW 2000 Case eee 3 7 Table 3 3 CAN BUS 3 11 Table 3 4 External Additional Signals 3 11 Table 3 5 CAN Bus TerminatiOn lt lt 3 20 Table 3 6 Device Addressing nee 3 21 Table 3 7 Device addressing for R amp S TS PXB2 3 22 Table 3 8 Characteristics of the R amp S 5 2 3 25 Table 3 9 Connectors on the R amp S 2 3 27 Table 8 1 Connector P20 up to Serial Number 100020 Slots 1 16 8 3 Table 8 2 Connector P20 as from Serial Number 100021 Slots 1 16 8 3 Table 8 3 Assignment XO PAT rss 8 4 Table 8 4 ATX Connector Assignment ns 8 6 Table 8 5 Assignment of X90 X93 224 444 444 444400000000n000n000nuu00000 0000000000 8 6 Table 8 6 to nid gts 8 7 Table 8 7 Jumper Field Assignment
80. the Rear I O side of the control backplane in the R amp S PowerTSVP Connector X30 is a 44 pin D sub socket High Density Jumper field X40 as well as the Jump ers JP2 JP6 JP7 and JP8 are placed on the circuit board Figure 3 17 Connectors and Jumpers on the R amp S TS PSYS2 Symbol Use X20 Rear I O X30 Front Connector X40 Jumper field Rear I O signals Table 3 9 Connectors on the R amp S TS PSYS2 3 27 ROHDE amp SCHWARZ Description 3 28 Test System Versatile Platform R amp S PowerTSVP TS PWA3 3 4 5 Functional Description of the R amp S TS PSYS2 see also Figure 3 16 3 4 5 1 Control The R amp S TS PSYS2 is controlled by the R amp S CompactTSVP or PC It provides two CAN bus channels type 2 0 A B to ISO 11898 CAN Internal connection for controlling the R amp S modules CAN2 General Usage The CAN lines are terminated manually with a jumper on the PSYS2 see Section 8 4 3 4 5 2 System Functions The system functions are implemented by an 8 bit microcontroller which operates at a 10 MHz system speed It communicates with the system controller in the R amp S CompactTSVP or PC across the CAN1 port The following functions are available 8x enable of PXI trigger signals to the outside e g R amp S Pow erTSVP 4x optocoupler outputs for PLC or handling systems 4x optocoupler inputs for PLC or handling systems e 2x enable for additi
81. the rear four feet as this will loosen the body of the case Affix the self adhesive plastic slide rails Place the unit into the rack on prepared aluminum rails Fix the R amp S PowerTSVP by screwing the 19 inch side brackets to the rack NOTE Check the position of the locknuts in the rack before sliding in the R amp S PowerTSVP If required insert and attach filter mats above and below the TSVP An optional telescopic rail set is also available The telescopic rails are fitted to the side of the BW 2000 case The R amp S PowerTSVP can then be pushed into the prepared support in the rack 4 2 3 Desktop Setup When the TSVP is set up on a desktop the minimum gap under the unit is provided by the feet on the BW 2000 case WARNING Do not obscure the ventilation louvers on the top of the unit The minimum clearance of half a height unit must be ensured 4 2 9th Issue 09 11 9th Issue 09 11 ROHDE amp SCHWARZ Test System Versatile Platform R amp S PowerTSVP TS PWA3 Commissioning 4 2 4 Operating Position The Test System Versatile Plattorm R amp S PowerTSVP can be operated in the following operating positions 1 Normally upright on the device bases on the bottom of the device 2 Supported on the rear bases on the bases holding the tube 3 Anytilt angles between the two above positions are possible NOTE For operating positions 2 and 3 or when equipped with R am
82. ting electrical separation insulation should be taken to avoid any hazards 10 Ensure that the connections with information technology equipment e g PCs or other industrial computers comply with the IEC60950 1 EN60950 1 or IEC61010 1 EN 61010 1 standards that apply in each case 11 Unless expressly permitted never remove the cover or any part of the housing while the product is in operation Doing so will expose circuits and components and can lead to injuries fire or damage to the product 12 If a product is to be permanently installed the connection between the PE terminal on site and the product s PE conductor must be made first before any other connection is made The product may be installed and connected only by a licensed electrician 13 For permanently installed equipment without built in fuses circuit breakers or similar protective devices the supply circuit must be fused in such a way that anyone who has access to the product as well as the product itself is adequately protected from injury or damage 1171 0000 42 05 00 Page 3 14 15 16 17 18 Basic Safety Instructions Use suitable overvoltage protection to ensure that no overvoltage such as that caused by a bolt of lightning can reach the product Otherwise the person operating the product will be exposed to the danger of an electric shock Any object that is not designed to be placed in the openings of the housing must not be used for this p
83. tion flexibility is achieved by a content oriented ad dressing scheme i e it defines so called message identifiers and not device addresses Systems can be added to an existing network with out the need for hardware or software modifications The CAN proto cols is defined in ISO 11898 Rear I O is the name given to a design that allows input and output lines of the cPCI connectors P1 and P2 to be accessed from the rear of a backplane Pluggable Rear I O modules can be used for this purpose in the R amp S CompactTSVP and the R amp S PowerTSVP 9th Issue 09 11 9th Issue 09 11 amp SCHWARZ Test System Versatile Platform R amp S PowerTSVP TS PWA3 Description 3 1 3 System Information R amp S PowerTSVP has a modular structure that allows a range of system configurations tailored to the specific needs of the user The R amp S PowerTSVP contains 16 slots for front plug in modules con forming to Rohde 8 Schwarz format The connector P2 that is defined in the cPCI standard is referred to here as P20 because of a different assignment Slots A4 are fitted with a PSU as standard An optional R amp S TS PCPA power pack or the optional R amp S TS PXB2 backplane extension can be plugged into slots A1 and A2 Slots 1 to 16 provide access to the PXI trigger bus CAN bus and analog bus If an optional R amp S TS PXB2 is used the CAN bus is also available at slots A1 and A2 Space for Rear I O modules is provided at the back
84. tional TS PSM1 is required it should be connected to slot 15 Plug In Modules ROHDE amp SCHWARZ Plug In Modules Test System Versatile Platform R amp S PowerTSVP TS PWA3 9th Issue 09 11 9th Issue 09 11 ROHDE amp SCHWARZ Test System Versatile Platform R amp S PowerTSVP TS PWA3 Interface description 8 Interface Description 8 1 Control Backplane 8 1 1 Position of Interfaces Slot1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Figure 8 1 Control Backplane Front View 0000000 22 Figure 8 2 Connector P20 Front Mating Side ROHDE amp SCHWARZ Interface description Test System Versatile Platform R amp S PowerTSVP TS PWA3 20 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 Slot EI Figure 8 3 Control Backplane Rear View 0000000 22 0000000 OOO00000 1 FEDCBAZ Figure 8 4 Connector P20 Rear Mating Side Note The count sequence is the mirror image of the front 9th Issue 09 11 ROHDE amp SCHWARZ Test System Versatile Platform R amp S PowerTSVP TS PWA3 Interface description 8 1 2 Connector P20 Slots 1 16 NC not connected NP not populated BPIO Backpanel I O c MEM LL n NO GO mau amr eee am um ce 2 run un numi PXLTRIGS Zz E PXI_STAR NC MICH Anasi
85. ure 8 2 Connector P20 Front Mating 5 8 1 Figure 8 3 Control Backplane Rear View 8 2 Figure 8 4 Connector P20 Rear Mating 8 2 Figure 8 5 Connector P47 Mating Side 8 4 Figure 8 6 Analog Bus Backplane Front 8 8 Figure 8 7 Analog Bus Backplane Rear 8 8 Figures ROHDE amp SCHWARZ Figures Figure 8 8 Figure 8 9 Figure 8 10 Figure 8 11 Figure 8 12 Figure 8 13 Figure 8 14 Figure 8 15 Figure 8 16 Figure 8 17 Figure 8 18 Figure 8 19 Test System Versatile Platform R amp S PowerTSVP TS PWA3 Connectors X1 X16 Mating Side 8 9 Connector X21 Mating nn 8 10 Connector X22 Mating Side 8 11 Power Backplane m ie 8 12 Connector X1 P47 Mating Side 8 14 R amp S TS PSYS2 Connector X20 Mating Side 8 16 R amp S TS PSYS2 Connector X30 Mating Side 8 17 Signals at the R amp S TS PSYS2 Jumper Field X4A0 8 18 Signals at the R amp S TS PSYS2 Jumper 2 8 18 R amp S TS PSYS2 Jumper JP6 and 8 18 Signal at
86. urpose Doing so can cause short circuits inside the product and or electric shocks fire or injuries Unless specified otherwise products are not liquid proof see also section Operating states and operating positions item 1 Therefore the equipment must be protected against penetration by liquids the necessary precautions are not taken the user may suffer electric shock or the product itself may be damaged which can also lead to personal injury Never use the product under conditions in which condensation has formed or can form in or on the product e g if the product has been moved from a cold to a warm environment Penetration by water increases the risk of electric shock Prior to cleaning the product disconnect it completely from the power supply e g AC supply network or battery Use a soft non linting cloth to clean the product Never use chemical cleaning agents such as alcohol acetone or diluents for cellulose lacquers Operation 1 Operating the products requires special training and intense concentration Make sure that persons who use the products are physically mentally and emotionally fit enough to do so otherwise injuries or material damage may occur It is the responsibility of the employer operator to select suitable personnel for operating the products Before you move or transport the product read and observe the section titled Transport As with all industrially manufactured goods the use of subst
87. ust be followed 4 2 Setting Up 4 2 1 Requirements for Repeatable Measurements The ambient conditions listed below are recommended for the installa tion site of a Test System Versatile Platform with R amp S PowerTSVP Temperature variance within 24 hours not to exceed approx 3 Maximum temperature variance within one hour not to exceed ap prox 0 5 C Extreme vibrations from mechanical or dynamic sources such as presses power punches etc must be avoided The TSVP should be warmed up for approx 15 minutes before measurements commence This time will depend on the type of measuring modules and can be longer Compliance with these guidelines will ensure accurate and re peatable measurements 4 2 2 Rack Mounting The rack mounting kit supplied by ROHDE amp SCHWARZ must be used for rack mounting the TSVP WARNING 3 A minimum clearance of half a height unit should be allowed above and below the R amp S PowerTSVP This space can be used to fit filter mats 9th Issue 09 11 The TSVP is installed in six steps Unscrew the four case feet from the base e Screw the 19 inch brackets contained the rack mounting kit un der the side handles replacing the old screws with the longer ROHDE amp SCHWARZ Commissioning Test System Versatile Platform R amp S PowerTSVP TS PWA3 SCrews Remove the four rubber tips from the feet WARNING Do not unscrew
88. y clean the R amp S PowerTSVP when it is powered down WARNING Electrical interfaces must not be cleaned with liquid products such as contact spray 6 2 Cleaning The following equipment and materials are recommended for cleaning the Test System Versatile Platform R amp S PowerTSVP Vacuum cleaner Brush Soft lint free cloths WARNING Never use aggressive products to clean the R amp S PowerTSVP Depending on the environmental conditions it may be necessary to re move the individual plug in modules from the R amp S PowerTSVP and clean them with a vacuum cleaner WARNING Comply with ESD electrostatic discharge regulations when working on the plug in modules of the R amp S PowerTSVP 6 1 ROHDE8SCHWARZ Maintenance Test System Versatile Platform R amp S PowerTSVP TS PWA3 6 3 Fuse Replacement The power supply to the R amp S PowerTSVP is protected by fuses These are located in the built in plug at the rear of the R amp S PowerTSVP x 2 ANALOG DNE Figure 6 1 R amp S PowerTSVP Rear View 1 Built in plug with fuses 2 x IEC 127 T6 3H 250V blown fuse is replaced as follows 2 3 4 Power off the R amp S PowerTSVP Isolate the R amp S PowerTSVP from the power supply built in plug Remove the fuseholder from the built in plug Replace the blown fuses NOTE
Download Pdf Manuals