ANAESTHESIA WORKSTATION

image

Contents

1. Vital Signs Monitoring TE monitoring systems from the David range o aoe mmmn Parameters ECG 5 T segment analysis Arhythmia Respiration p0 2xTemp NIBP Printer 2xIBP Cardiac Output EtCO Anaesthetic agents Bed to bed view Drug Dose Calculation i4 jea z ve sees PALE aw The Morpheus can be combined with various sitio 0o E Art 786 2003 ANAESTHESIA WORKSTATION TECHNICAL DATA SHEET light aluminiumalloy varnished steel and plastic moulds N 3 Vertical cylinders support On the back side For up to 7 lt capacity cylinders Dimensions O 80x65x144 UxDat em vith monitor supportam Mechanic gas mixing device General description It has the function to regulate the capacity and the concentration of gas mixture Air O2 N20 as well as to deliver it to the anaesthetic gas vaporizer It allows to select the mixture to be delivered Air O2 or N O O gt and the O2 enrichment to the delivered mixture in emergency situations It includes a device which guarantees a minimum concentration of 25 oxygen in all gas erogating conditions MIX LIFE device Through the three pressure gauges on the front panel it allows the continuous control of medical gas feeding pressure coming from the gas pipelines system Oxygen rotameter Scale 0 2 12 l min Resolution 0 1 l min up to 1 l min and 0 5 l min up to 12 l min Accuracy 10 of the displayed value or 1 of end scale whichever is the worse case Nit
2. Description MORPEUS Anaesthesia workstation The Morpheus is a workstation for gaseous anaesthesia It can be used on adult paediatric and neonatal patients The construction materials are the most innovative and suitable for use in hospital environment and they allow to have a light and ergonomic system and easy to clean The electronic control guarantees technologically advanced lung ventilation and it is able to meet the needs of the different application fields for which the systems was designed The Morpheus is designed for administering O2 Air N20 Halothane Enflurane Isoflurane Sevoflurane Desflurane Halocarbon The machine is equipped with an automatic system which verifies at each Start up all important safety parameters for approx 5 minutes AUTO TEST Specially the flows the pressures and all electronic hardware and software are verified as well as the automatic O2 probe calibration with the consequent automatic identification of an eventual gas inversion In order to use the machine in emergency case the above mentioned AUTO TEST can be interrupted at anytime The unit Morpheus is completed with Mechanic gas mixing device O02 N20 AIR Electronic ventilator Breathing monitoring system Heated closed open valves group w 2 5 Kg CO2 absorber Double interlock selectatec support for 2 vaporizers Adultes silicone patient circuit for aut man ventilation User s manual Optionals
3. ERY OF AIR AND N20 Selecting valve on the front panel Deviator with double outlet Device to deviate fresh gas addressing them to the anaesthesia unit valves group or to a To and Fro patient circuit for manual ventilation Auxiliary gas outlets 3 5 bar emergency oxygen 0 75 air compressed oxygen for lung ventilator air compressed oxygen for active gas scavenger if present air compressed oxygen for tracheal aspirator if present O2 emergency By Pass By push button On the front panel Mas flow 901 min Fresh gas outlets N 1 Automatic connection for the Breathing System N 1 On the front panel for the To and Fro system selectable by dedicated lever on the front panel Breathing System General description Compact system with automatic connections easy dismountable and autoclavable Functionality It allows the ventilation in modality real open circuit semi closed circuit closed circuit The system also allows the spontaneous and manual ventilation also in case of machine breakdown or machine off The CO2 absorber canister has a rapid connection and this allows its replacement also during operation The recycling system is a selective type hence the soda lime and fresh gases consumption is reduced to the minimum Reservoir bag orientable support to facilitate the manual ventilation The circuit is heated to reduce condensation and heat the fresh gases The switching from one modality to another is comp
4. letely controlled by ventilator without any user s action on valves group All group internal connections are stainless steel made The group is completely autoclavable and does not have disposable parts Art 786 2003 ANAESTHESIA WORKSTATION Lung Ventilator Type of ventilation IPPV Control modality Electronic by microprocessor The equipment is equipped of an electronic systems which at every start up for around 5 minutes verifies all setted parameters for safety purposes AUTOMATIC TESTS In particular it verifies flows pressures and all the hardware and software electronic parts automatic compensation of dead space O2 cell automatic calibration and the leakages test In order to use the equipment in emergency cases the AUTO TEST can be interrupted at any time Flow generation Proportional valve Gas feeding Medical compressed air or Oxygen at 3 5 bar 0 75 Ventilation modes IPPV AST PCV SPONT SIMV MANUAL performable both by breathing system that with and external manual system for ex To and Fro Measured parameters O2 concentration Max and Mean airways pressure Flow from 1 to 100 I min tidal volume minute volume and breathing rate Breathing rate From 5 to 70 bpm LE Ratio 1 1 1 1 5 1 2 1 3 1 4 2 1 3 1 Settable by inspiratory time Inspiratory time 20 25 33 40 50 67 75 of breathing cycle Frequency in SIMV From 0 to 69 Tidal Volume From 5 to 1500 ml Minute Volume From 1
5. rous oxyde rotameter Scale 0 2 12 l min Resolution 0 1 l min up tol l min and 0 5 l min up to 12 l min Accuracy 10 of the displayed value or 1 of end scale whichever is the worse case Air rotameter Scale 0 2 12 l min Resolution 0 1 l min up to 1 l min and 0 5 l min up to 12 l min Accuracy 10 of the displayed value or 1 of end scale whichever is the worse case Medical gas supply OXYGEN Pressure at 3 5 bar 0 75 Max required flow 90 l min NITROUS OXYDE Pressure at 3 5 bar 0 75 Max required flow 15 l min MEDICAL COMPRESSED AIR Pressure at 3 5 bar 0 75 Max required flow 90 l min Control gauges N 3 Scale 0 10 bar O2 N20 ARIA On the front panel Vaporizer connection Double vaporizer connection Selectatec type with system which avoid the contemporary opening of the 2 vaporizers Art 786 2003 ANAESTHESIA WORKSTATION Safety devices AGAINST THE ADMINISTRATION OF HYPOXIC MIXTURES MIX LIFE Guarantees a minimum concentration of 25 oxygen on mixtures that include nitrous oxide N20 IN CASE OF LACK OR LOW OXYGEN PRESSURE CUT OFF Audible alarm with immediate cut off of nitrous oxide delivery AGAINST HIGH PRESSURE IN SUPPLY Safety valve calibrated at 0 8 bar for the protection of the glass rotameters IN CASE OF LACK OR LOW COMPRESSED AIR PRESSURE All the devices supplied with compressed air are automatically supplied by oxygen except the flowmeter AGAINST THE CONTEMPORANEOUS DELIV
6. to 30 liters with INSP at 33 PEEP 0 20 cm H20 Inspiratory Flow From 0 to 100 litri min O t Built in with display of O2 concentration A Min resolution 1 Automatic calibration procedure Electronic with led bar and display from 10 to 80 cm di H20 Trigger sensibility Electronically adjustable in continuous way from 9 to 20 cm di H20 Power failure Low battery Gas supply Wrong O97 concentration Low and high airway pressure Apnoea Airways pressure limit During the self diagnosys Alarms the machine signals failures or wrong connections suggests the exhaust O7 sensor replacement and every 1000 hours operation it suggests maintenance service Apnoea High and low minute volume failure Electric power supply 220 Vac 50 60 Hz 110 Vac optional Battery operation With internal Pb battery approx 2 hours operation Self diagnosys system User s interface LED Display Led bar bronchomanometer RINE onertinsesoe Conor buttons and knobs Displayed Curves Pressure and flow curves on enlightened LCD monitor External connections RS232 serial connector connector for software refreshments Art 786 2003 ANAESTHESIA WORKSTATION Standard accessories To and Fro Mapleson C code 002627EN O2 supply tube code G60005100 N20 supply tube code G60006100 AIR supply tube code G60007 100 FiO2 cell cable code E75000004 E85500999 Electric supply cable code G30105100 Patient circuit code 102634 Flo
7. w transducer code G80053000 E85501249 Optional Accessories Articulated arm in light alloy for patient circuit Tracheal aspirator kit with Venturi system Oxygen therapy kit Lateral arm for monitor support Active gas scavenger Passive gas scavenger Vaporizers Halothane Isoflurane Sevoflurane Enflurane RGA Anaesthetic Agents Monitor DAVID Serie Vital Signs Monitor TWINRESP a second emergency ventilator presetted with fix data to continue the ventilation in the case of failure of the first ventilator Rate 12 Tidal Volume 600ml I E Ratio 1 2 Limit Pressure 20 cm H20 Lung Ventilators IEC 601 2 12 CEI 62 20 ISO 5369 Anaesthesia equipment IEC 601 2 13 CEI 62 21 BS 4272 part 3 Connections EN 1281 1 Electromagnetic IEC 601 1 2 CEI 62 50 89 336 Compatibility EMC Art 786 2003

Download Pdf Manuals

image

Related Search

Related Contents

HP DL380 Installation Guide  Bosch NDN-733V02-IP surveillance camera  Expiry Date - NHS Leicester City  Approche pratique dans une stratégie marketing de PME  - OMEGA Engineering  Kenwood Electronics KDC-BT42U car media receiver  MANUAL DE INSTRUCCIONES INSTRUCCIONES  DLM 2000 Series - Excalibur Engineering  Manual de usuario  GSP-1700 - Global Marine Networks  