Home

Data Sheet

image

Contents

1. 07 Keysight Advanced Power System N6900 and N7900 Series Power Supplies Brochure Properly powering on and off your DUT with the APS If you work with DUTs that have multiple power supply inputs such as satellite payloads you often need to properly sequence on or off each power supply at strictly repeatable times to prevent current surges and latch up conditions In addition to sequencing on or off each supply you may need to set the ramp rate of each supply at turn on or turn off to a particular rate These requirements add significant complexity to an ATE test system both in hardware and software The APS power supplies can help you overcome this test challenge by providing built in sequencing capability across APS mainframes or with Keysight s popular N6700 family of modular system power supplies Also the APS power supplies provide adjustable slew rate control at turn on or turn off These built in capabilities provide a clean low complexity way to properly power on or off your DUT during test Add power lexibility to your test system by paral leling multiple APS supplies Paralleling multiple power supplies together is a great way to add power flexibility to your test system The down side of paralleling power supplies together is typically you cannot get all the supplies to operate in the desired constant voltage CV or constant current CC mode For instance when trying to operate in CV mode with two parallel
2. Continental Europe 903 Power cord United States and Canada 120 V 904 Power cord United States and Canada 240 V 906 Power cord Switzerland 912 Power cord Denmark 917 Power cord India 918 Power cord Japan 100 V 919 Power cord Israel 920 Power cord Argentina 921 Power cord Chile 922 Power cord China 250 V 923 Power cord South Africa 927 Power cord Thailand and Philippines 929 Power cord Japan 250 V 930 Power cord Brazil 391 Power cord Taiwan 932 Power cord Cambodia PLG Continental European power cord only for EU DISTR W MULT PWR CORD standards 16 Keysight Advanced Power System N6900 and N7900 Series Power Supplies Brochure myKeysight WARRANTY WARRANTY N6 00 provides a modular 500 W and below ATE system DC power solution myKeysight www keysight com find mykeysight A personalized view into the information most relevant to you Three Year Warranty www keysight com find ThreeYearWarranty Keysight s commitment to superior product quality and lower total cost of ownership The only test and measurement company with three year warranty standard on all instruments worldwide Keysight Assurance Plans www keysight com find AssurancePlans Up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements www keysight com go quality Keysight Technologies Inc DEKRA Certi
3. 0 04 2 4 mA 28 1 A to 28 1 A 56 2 A to 56 2 A 1 37 A to 1 37 A 2 7 5 Ato 2 75 A 100 us 200 mV 3 ms 10 ms 0 5 ms 1ms 0to6 4 3 20 0 1296 412 8 mO A 54 uO 27 WO N6976A Oto 120 V 16 7A 1 67 A 16 7 A 2 kW 2 mV 30 mV 4 mV 1 mA 0 03 17 mV 0 03 23 mV 0 03 11 mV 0 03 17 mV 0 1 5 mA 0 04 2 5 mA N A 37 6 A to 37 6 A N A 1 84 A to 1 84 A 100 us 300 mV 3 ms 10 ms 0 5 ms 1 ms 0 to 6 8 Q 0 1296 17 7 mQ A 60 uQ N6977A Oto 160 V 12 5 A 1 25 A 12 5 A 2 kW 3 mV 30 mV 4 mV 0 8 mA 0 03 24 mV 0 03 32 mV 0 03 14 mV 0 03 22 mV 0 1 4 mA 0 04 2 mA N A 28 1 A to 28 1 A N A 1 37 A to 1 37 A 100 us 400 mV 3 ms 10 ms 0 5 ms 1 ms 0to 12 80 0 1296 25 6 mO A 108 uO 12 Keysight Advanced Power System N6900 and N7900 Series Power Supplies Brochure N7900 specifications 1 kW 2 kW Table 5 N7950A 70A N7951A 71A N7952A 72A N7953A 73A N7954A 74A N7976A N7977A DC ratings Voltage range 0 to 9 V Oto 20 V Oto 40 V Oto 60 V Oto 80 V Oto 120 V Oto 160 V Current max 100A 200A 50A 100A 25A 50A 16 7A 33 3A 12 5A 25A 16 7A 12 5A Current sink 10 10A 20A 5A 10A 2 5A 5A 1 67A 3 33A 1 25 A 2 5 A 1 67 A 1 25 A Current sink 100 100 A 200 A 50 A 7 100 A 25 A 50A 16 7 A 33 3 A 12 5 A 25 A 16 7 A 12 5 A Power 900 W 1 8 kW 1 kW 2 kW 1 kW 2 kW 1 kW 2 kW 1 kW 2 kW 2 kW 2 kW Output ripple amp n
4. 30 60 mA 0 04 15 30mA 225 Ato 225A 450 Ato 450A 11 Ato 11A 22 Ato 22 A 100 us 150 mV 3 ms 10 ms 0 5 ms 1 ms 0 to 0 1 0 050 0 12 1 6 mQ A 0 8 uQ 0 4 uQ N6951A 71A Oto 20 V S0A 100A bA 10A 50A 100A 1 kW 2kW 1 mV 9 mV 0 75 mV 3 mA 6 mA 0 03 3 mV 0 03 4 mV 0 03 2 mV 0 03 3 mV 0 1 15 30 mA 0 04 8 15 mA 112 5At0112 5A 225 Ato 225A 5 5 A to 5 5 A 11 Ato 11A 100 us 150 mV 3 ms 10 ms 0 5 ms 1ms 0to0 4 0 20 0 1296 3 2 mO A 3 5 uQ 1 7 uQ N6952A 72A Oto 40 V 25A 50A 2 5A 5A 25A 50A 1 kW 2kW 1 mV 9 mV 1 5 mV 1mA 2mA 0 0396 6 mV 0 0396 47 9 mV 0 03 4 mV 0 03 5 9 mV 0 196 8 15 mA 0 0496 4 8 mA 56 2 A to 56 2 A 112 5 A to 112 5A 2 5 Ato 2 75 A 5 5 A to 5 5 A 100 us 100 mV 3 ms 10 ms 0 5 ms 1 ms 0 to 1 6 0 80 0 12 6 4 mQ A 13 yO 7 WO N6953A 73A Oto 60V 16 7 A 83 3 A 1 67 A 3 33A 16 7 A 33 3 A 1 kW 2kW 1 mV 9 mV 2 mV 1mA 1 5 mA 0 03 9 mV 0 03 12 mV 0 03 6 mV 0 03 9 mV 0 1 5 10mA 0 04 2 5 5mA 37 6 Ato 37 6 A 74 9 A to 74 9 A 1 84 A to 1 84 A 3 67 A to 3 67 A 100 us 150 mV 3 ms 10 ms 0 5 ms 1 ms 0t03 4 170 0 12 8 8 mQ A 30 10 15 po N6954A 74A Oto 80 V 12 5A 25A 1 25A 2 5A 12 5A 25A 1kW 2 kW 1 mv 9 mV 2 mV 0 8 mA 1 5 mA 0 03 12 mV 0 03 16 mV 0 03 8 mV 0 03 12 mV 0 1 4 8 mA
5. positive current measurement ranges 3 Expressed as of setting or of measurement offset At 23 C 5 C after 6 These are supplemental characteristics 13 Keysight Advanced Power System N6900 and N7900 Series Power Supplies Brochure Two quadrant specifications Voltage rating Current 0 Current rating rating Key __ Sourcing power EE Sinking power up to 1096 of rating without dissipater Eee Sinking power up to 10096 of rating with dissipater Table 6 N6950A 70A N6951A 71A N6952A 72A N6953A 73A N6954A 74A N7950A 70A N7951A 71A N7952A 72A N7953A 73A N7954A 74A Voltage rating 9v 20 V 40 V 60 V 80 V Current rating 100 A 200 A 50 A 100 A 25 A 50 A 16 7 A 33 3 A 12 5 A 25 A Curr rating w dissipater 100 A 200 A 50 A 100 A 25 A 50A 16 7 A 33 3 A 12 5 A 25 A V1 0 68 V 0 523 V 1 8 V 1 47 V 2 0 V V2 0 068 V 0 0525 V 19V 147 V 0 2 V N6976A N7976A 120 V 16 7 A 16 7 A 3V 0 3 V N6977A N7977A 160 V 12 5 A 12 5A 4V 0 4 V 14 Keysight Advanced Power System N6900 and N7900 Series Power Supplies Brochure APS General Information APS N6900 Series and N 900 Series power sup ply power requirements Connect the power cord that was supplied with your unit to the AC mains connector on the rear of the unit Note that these cords are standard and are specially rated to handle the power needs of the APS supply they are shipped with The AC input on the back of your unit
6. refer to the APS user manual at www keysight com find APS doc Figure 9 Black box recorder data displayed within the N7906A Power Assistant software Threshold Protect Routing gt Custom OR User ide Threshold E Event1 Event Event2 Figure 10 Configuring a trigger expression with the N7906A Power Assistant software 10 Keysight Advanced Power System N6900 and N7900 Series Power Supplies Brochure Differences Between the APS N6900 Series and N 900 Series Table 3 This table compares performance specifications and features of the N6900 DC Series power supplies and the N7900 Series dynamic DC power supplies Feature N6900 1 kW and 2 kW models N7900 1 kW and 2 kW models Voltage and current programming 16 bit with option 303 16 bit precision Voltage and current measurements 18 bit precision 18 bit precision Voltage up down programming time nade s ms with option 303 0 5 ms 35 ms Transient response time recovery time 100 us 100 us Two quadrant operation 1096 standard 10096 optional Yes Yes omart triggering Yes Yes Power storage and efficiency measurements Yes Yes Output sequencing adjustable slew rate Yes Yes Parallel operation Yes Yes Low current measurement range Yes with option 301 Yes oeamless current measurements Yes with option 301 Yes V and digitizers with programmable sample rates Yes with option 302 Yes External logging capability Yes with option 302 Yes Output list capab
7. is a universal AC input It accepts nominal line voltages in the range of 100 VAC to 240 VAC The frequency can be 50 Hz 60 Hz or 400 Hz AC mains rated below 180 VAC cannot supply enough current to power either the 1 kW or the 2 kW N6900 and N7900 models to their full rated output power In such cases when a 1 kW or 2 kW APS power supply is connected to below 180 VAC AC mains the power supply will still operate normally but its maximum output power will be limited to 700 W In this condition if the power supply exceeds 700 W of output power the instrument turns off the output and sets the CP status bit APS power supply connectivity All APS power supplies come standard with GPIB IEEE 488 LAN LXI Core and USB remote programming interfaces GPIB and LAN parameters can be set via the front panel The APS is LXI Core 2011 compliant and includes a built in Web interface This means you can control the APS remotely using a Web browser and a LAN connection APS weight and dimensions Weight and dimensions are the same for the N6900 Series and N 900 Series APS power supplies 1 kW power supplies Weight 24 lbs 10 9 kg Dimensions L 22 39 in 568 7 mm W 16 81 in 426 9 mm H 1 75 in 44 45 mm 2 kW power supplies Weight 34 lbs 15 5 kg Dimensions L 24 928 in 633 2 mm W 16 81 in 426 9 mm H 3 468 in 88 1 mm Power dissipater unit Weight 18 lbs 8 2 kg Dimensions L 19 81 in 503 3 mm W 16 81
8. operation Note that you can use a single N 909A with a 2 kW APS power supply to achieve 50 current sink capability The N7909A is a separate user configurable hardware accessory You can order it at any time and connect it to your APS power supply otep 4 Order hardware for mounting the APS in an ATE system To mount any N6900 Series or N7900 Series power supply or the N 909A dissipater use the N 90 A APS rack mount kit The N7907A will work with both 1 kW and 2 kW APS power supplies A N7907A APS rack mount kit is needed for every APS power supply or N7909A dissipater that you would like to mount For other rack mount options and for product dimensions refer to the user manual at www keysight com find APS doc otep 5 Choose calibration and power cord options These options only apply to APS power supplies since they are the only units in the APS family that need to be calibrated or plugged into AC power When ordering to specify a particular option with an APS supply simply append the option number to the power supply model number For instance to order a power cord that works in Switzerland for your 40 V 1 kW dynamic DC power supply you would specify N 7952A 906 for your order Table 9 APS N6900 Series and N7900 Series options Option number Description 1A7 ISO 17025 cal certificate UK6 Commercial calibration with test results data 900 Power cord United Kingdom 901 Power cord Australia and New Zealand 902 Power cord
9. supplies one will typically source the bulk of the current and operate in CC mode and the other Supply will source only a fraction of the current and operate in CV mode This condition can highly degrade certain power supply performance specifications such as transient response With the APS you do not have to worry about this since it has built in paralleling capability that ensures each supply equally shares the load current so they all remain in the desired mode whether it is CV or CC Note that paralleling works whether the APS power supplies are sourcing or sinking current from the DUT To take advantage of the APS paralleling capability you need only a simple three wire connection in the rear of the supplies in the parallel configuration see Figure 6 With this capability you can parallel up to five APS power supplies recommended which provides a max power of 10 kW Figure 6 An APS supply s three wire connection for paralleling multiple supplies For more Information on how the APS can help you overcome your power related test challenges including videos application notes and example code visit www keysight com find TestChallenges 08 Keysight Advanced Power System N6900 and N7900 Series Power Supplies Brochure APS Hardware Accessories and Software gt APS N 909A power dissipater unit The optional N 909A power dissipater unit adds current sinking or two quadrant operation to any N6900 or N7900
10. 829 4444 800 629 485 800 810 0189 800 938 693 1 800 11 2626 0120 421 345 080 769 0800 800 888 848 1 800 375 8100 0800 047 866 65 6375 8100 0800 001122 0800 58580 0800 523252 0805 980333 0800 6270999 1800 832700 1 809 343051 800 599100 32 800 58580 0800 0233200 8800 5009286 800 000154 0200 882255 0800 805353 Opt 1 DE Opt 2 FR Opt 3 IT 0800 0260637 For other unlisted countries www keysight com find contactus BP 04 23 15 This information is subject to change without notice Keysight Technologies 2013 2015 Published in USA September 24 2015 5991 2698EN www keysight com
11. 9096 0 5 ms 0 5 ms 0 5 ms 0 5 ms 0 5 ms 0 5 ms 0 5 ms settling time ms ms ms ms ms ms ms Volt down programming timeo 9096 to 1096 0 35 ms 0 35 ms 0 35 ms 0 35 ms 0 35 ms 0 35 ms 0 35 ms settling time 0 8 ms 0 8 ms 0 8 ms 0 8 ms 0 8 ms 0 8 ms 0 8 ms Voltage programming bandwidth no load 3 dB point 2 kHz 2 kHz 2 kHz 2 kHz 2 kHz 2 kHz 2 kHz 1 dB point 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz Curr up programming timeo 1096 to 9096 2 5 ms 2 5 ms 2 5 ms 2 5 ms 2 5 ms 2 5 ms 2 5 ms Current programming bandwidth resistive load 3 dB point 160 Hz 160 Hz 160 Hz 160 Hz 160 Hz 160 Hz 160 Hz 1 dB point 70 Hz 70 Hz 70 Hz 70 Hz 70 Hz 70 Hz 70 Hz Resistance programming SOS Range 0t001 005Q 0t004 020 01016 080 0Q134 170Q 0t06 4 3 20 iio per 0to 12 8 0 Accuracy 0 069641 6 mQ A 0 0696 3 2 mQ A 0 0676 6 4 m 906954 8 8mO A 0 0696 12 8 mQ A Aou 0 08 25 6 mQ A Resolution 08u0 04uQ0 34y40 17gQ 13 0 70 30 10 15 pO 540 27 u0 60 ud 108 uQ 1 Current sinking up to 100 of rated current requires one N7909A power a 30 minute warm up measurement NPLC 1 valid for 1 year dissipater for 1 kW models and two N7909A power dissipaters for 2 kW 4 Time to recover within the settling band following a load change from 50 to models 2 kW models with one power dissipater can sink 5096 of their rated 10096 of full load current 5 When sinking current the negative current measurement ranges match the 2 From 20 Hz to 20 MHz
12. Keysight Technologies Advanced Power system N6900 and N7900 Series Power Supplies 1 Mu iJ i n P P a 4 STREET UT z5 UUA Tr j at i EIE a LI a X 1 i 2 KEYSIGHT TECHNOLOGIES 02 Keysight Advanced Power System N6900 and N7900 Series Power Supplies Brochure Advanced Power System APS Overview Overcome your power test challenges with the Get lots of power in a small test system footprint Advanced Power System family Two power ranges deliver a large amount of power in a small With the Keysight Technologies Advanced Power System APS test system footprint 1 kW and 2 kW system power supplies you get a new level of power supply performance The Advanced Power System APS family was designed with VersaPower architecture to help you overcome your toughest power test challenges by delivering industry leading specifications and innovative features in an integrated solution for today s advanced ATE power testing needs 1 kW models have a 1U full rack footprint 2 kW models have a 2U full rack footprint Both power ranges have built in paralleling capability up to 10 kW VersaPower architecture delivers the fastest most accurate integrated power system 1000 W in 1U l ac All Accelerate test system throughput with m industry leading speed accurate measurements um Reduce your ATE development time and cost with highly integrated capabilities Capture your D
13. N6900 Series DC power supplies Designed for ATE appli cations where high performance is critical N7900 Series dynamic DC power supplies Designed for ATE applications where high speed dynamic sourcing and mea surement is needed Refer to Table 3 on page 10 for an in depth performance and feature comparison of the N6900 Series and the N7900 series For N6900 choose performance options from Table 8 Table 8 APS N6900 Performance Options Option number Description 301 Accuracy Package 307 Measurement Enhancements ou oource and Speed Enhancements 60 761 Disconnect and Polarity Reversal Relays otep 2 Choose the right power voltage and current level Choose the right APS power supply model based on your power voltage and current needs Refer to Table 1 on page 2 for a full list of APS power supplies otep 3 Select the right optional hardware accessories The APS includes two user configurable hardware accessories for increasing the capability of an N6900 Series or N 900 Series power supply APS N7909A power dissipater unit and the APS N 908A black box recorder If you want to have full two quadrant operation for your APS power supply you will need one or two APS N 909A power dissipater units Each N 909A adds 1 kW current sinking capability to an APS power supply so for 1 kW APS power supplies you need one N 909A for full two quadrant operation and for 2 kW APS power supplies you need two N7909As for full two quadrant
14. UT s current profile with 2000 W in ud B Choose the right APS performance class to meet your needs Keysight N6900 Series Designed for ATE applications where high performance is critical DC power supplies Add performance options to get the dynamic test capabilities of the N 900 Keysight N 900 Series Designed for ATE applications where high speed dynamic sourcing and measurement is needed dynamic DC power supplies Choose the APS model with the voltage and current you need Both the N6900 Series DC power supplies and the N7900 Series dynamic DC power supplies provide five voltage and current combinations at the 1 kW power range and seven voltage and current combinations at the 2 kW power range Keysight N6900 Series DC power supplies Keysight N7900 Series dynamic DC power supplies 1 kW models 2 kW models 1 kW models 2 kW models N6950A 9V 100A N6970A 9 V 200A N7950A 9V 100A N7970A 9V 200A N6951A 20V 50A N6971A 20V 100A N7951A 20V 50A N7971A 20V 100A N6952A 40V 25A N6972A 40V 50A N7952A 40V 25A N7972A 40V 50A N6953A 60V 16 7A N6973A 6OV 33A N7953A 60V 16 7A N7973A 60V 33A N6954A 80V 12 5A N6974A 80 V 25A N7954A 80V 12 5A N7974A 80V 25A N6976A 120V 16 7 A N7976A 120V 16 7 A N6977A 160V 12 5 A N7977A 160V 12 5 A 03 Keysight Advanced Power System N6900 and N7900 Series Power Supplies Brochure Test challenges and how the APS helps you overcome them The APS with Keysight s exclusive VersaPower architecture he
15. amount of protection hardware needed in the test system reducing complexity and development time With protection features integrated into the instrumenta tion the amount of hardware needed for the test system is reduced which in turn lowers test system support costs With protection measures implemented in hardware rather than test system software error conditions can be detected and handled much faster reducing the likelihood of the DUT sustaining major damage The APS power supplies feature advanced and fast protection capabilities fully integrated These protection capabilities include Fast CC CV mode crossover as well as user settable voltage and current priority modes to reduce unwanted voltage or current overshoots Smart triggering Over and under voltage and current protection Fast reaction to error conditions Output disconnect relays User configurable watchdog timer Broken and shorted sense line detection Generate voltage and current transients DUTs that are operated in rugged environments such as automotive electronics and avionics can often experience transient behavior from the power source such as voltage dropouts or surges To ensure your DUT can stand up to these real world transients you must simulate worst case power transient conditions in the test process The APS power supplies provide three different functionalities for simulating either voltage or current transients for te
16. ated output current sinking capability without the N7909A power dissipater unit Note Even though the APS s two quadrant operation gives it much of the same functionality as a DC electronic load it cannot simulate current transients as fast as an electronic load For instance the APS can simulate full range current transients at 5 ms where a high performance electronic load can achieve current transients 1 ms See the specifications and user guide at for more information at www keysight com find APS doc APS N 908A black box recorder Much like a flight data recorder the N 908A black box recorder BBR runs continually in the background independent of what the power supply is doing When the power supply is on the BBR Is recording power events and storing measurements in non volatile memory The BBR can be set for either a 24 hour record or a 10 day record period In the 24 hour mode measurements are made at a rate of 100 per second and in the 10 day mode they are made at a rate of 10 per second The BBR data can be accessed via the free APS power assistant software see Figure 9 on page 9 The BBR is a user installable hardware option and it works in all APS N6900 and N 900 power supplies You can purchase the N 908A BBR with an APS power supply or buy it later and install it in your existing APS power supply The BBR hardware board plugs into the bottom of an APS power supply as shown in Figure 8 Figure 8 Installing
17. e control 04 Keysight Advanced Power System N6900 and N7900 Series Power Supplies Brochure A Deeper Look at How the APS Can Help You Overcome Your Power Test Challenges Accelerate test throughput with industry leading specifi cations Shaving seconds or even milliseconds off a test time can lead to significant savings for high volume manufacturers making throughput gains a never ending quest for test system designers The APS is a valuable tool for increasing throughput It provides a number of industry leading specifications and innovative features that can help you achieve significant throughput gains in your testing Some examples Industry leading command processing time lt 2 ms Fast up and down programming speeds up to 500 us Adjustable measurement times for optimum measurements in minimum time Current Seamless ranging capability for fast current Time in saconds measurements without sacrificing accuracy Output lists that allow you to step through timed or Figure 1 Dynamic current measurement triggered voltage or current levels that can also generate triggers for tightly synchronized measurements Accurately measure power storage and efficiency In addition to high accuracy voltage and current measurement capabilities APS Accu rately enaracter power supplies offer built in power peak power amp hour and ize your DUT s power watt hour calculations These measurements help simplify you
18. fied ISO 9001 2008 Quality Management System Keysight Channel Partners www keysight com find channelpartners Get the best of both worlds Keysight s measurement expertise and product breadth combined with channel partner convenience www keysight com ind N6 00 The Keysight N6700 modular power system is small flexible and fast Ideal for ATE systems in R amp D design validation and manufacturing Small size Up to 4 outputs in 1U of rack space Flexible modular system You can mix and match power levels and performance levels to optimize your investment Uses the same modules as the N6 05 DC power analyzer Fast command processing time to improve throughput Connect via GPIB LAN L XI Core or USB Complete specifications can be found in the N6700 Modular Power System Data Sheet publication 5958 1411EN KEYSIGHT TECHNOLOGIES For more information on Keysight Technologies products applications or services please contact your local Keysight office The complete list is available at www keysight com find contactus Americas Canada Brazil Mexico United States Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Other AP Countries Europe amp Middle East Austria Belgium Finland France Germany Ireland Israel Italy Luxembourg Netherlands Russia spain Sweden Switzerland United Kingdom 877 894 4414 o5 1 5991 7010 001 800 254 2440 800
19. g on off a DUT To prevent damage at turn on or turn off you need to properly sequence multiple supplies on off or tune their Slew rates How the APS helps you overcome the challenge Fast up and down programming speeds up to 500 us Fast command processing lt 2 ms List capability to step through a list of voltage or current levels seamless ranging capability for fast current measurements without sacrificing accuracy Full two quadrant glitch free operation across quadrants Voltage and current limit settings to keep your device within its operating range smart triggering Fast output response Output disconnect relays Watchdog timer 18 bit high resolution current digitizer Adjustable measurement sample rate External logging capability Peak triggering and measurements AWG capability step function capability High bandwidth mode High resolution current and voltage digitizers Pre and post triggering for capturing measurement data Large current range that is over 2x the rated output of the power supply Fast transient response to ensure minimal voltage droop to load transients High and low output bandwidth settings for tuning the output to your load Built in Black Box Recorder Records voltage current power trigger events mode changes and more in non volatile memory oequencing capability across multiple APS supplies Sequencing capability with Keysight s N6700 modular power supply family Adjustable slew rat
20. ignal another instrument in the test system to do something after a voltage or current change Track power events with a black box recorder If you are testing expensive prototypes and a power related problem damages or destroys your DUT you need to figure out what went wrong to ensure it does not happen again The APS s optional N7908A black box recorder BBR overcomes this test challenge by creating a power event record inside the power supply Much like an airplane flight data recorder the APS black box recorder is always recording events When the power supply Is on it is always running recording power events and making measurements in non volatile memory regardless of what the power supply is doing or how it is being used 06 Keysight Advanced Power System N6900 and N7900 Series Power Supplies Brochure Examples of what it records Voltage min max and avg current min max and avg and power min max and avg Trigger events Status bits Front panel and command events User defined tags See page 8 for more information on the APS N7908A BBR Avoid damage to your DUT with APS protection When you are testing costly DUTs integrating power protection measures into the test system is critical Using instrumentation with built in protection features provides a huge benefit when DUT protection is required Here s why Built in protection features such as broken sense line de tection reduce the
21. ility Yes with option 303 Yes Arbitrary waveform generation Yes with option 303 Yes Output relays disconnect and polarity reversal Yes with Option 760 761 Yes 1 For detailed speciications see APS user manual 2 N6950A N7950A and N6970A N7970A only have output disconnect relays no polarity reversal relays 11 Keysight Advanced Power System N6900 and N7900 Series Power Supplies Brochure APS Specifications For more detailed specifications refer to the APS user manual at www keysight com find APS doc N6900 specifications 1 kW 2 kW Table 4 DC ratings Voltage range Current max Current sink 1096 Current sink 100 Power Output ripple amp noise CV rms CV peak to peak Load regulation Voltage Current Volt programming amp meas accuracy Lead drop 1 V max Lead drop 2596 of V rating with option 301 Curr programming and measurement accuracy with Option 301 Curr Measurement ranges with Option 301 High range N695x High range N697x Low range N695x Low range N69 x Transient response Recovery time settling band Volt up amp down programming time 1096 to 90 and 90 to 1096 Settling time w Option 302 Volt up programming Time Resistance programming Range Accuracy Resolution N6950A 70A 0to9V 100A 200A 10A 20A 100 A 200 A 900 W 1 8 kW 1 mV 9 mV 0 5 mV 8 mA 15 mA 0 0396 41 5 mV 0 0396 1 9 mV 0 0396 1 mV 0 03 1 4 mV 0 1
22. in 426 9 mm H 1 75 in 44 45 mm APS digital control port On the rear panel of every APS power supply is a digital control port that consists of seven I O pins that provide access to various control functions as shown in Figure 11 Each pin is user con figurable Table 7 describes the possible pin configuration for the digital port functions For more information on the digital control port and how to configure it refer to the Advanced Power System user guide at www keysight com find APS doc Figure 11 Digital control port on rear panel Table 7 Digital control port description Available configurable pins Pins 1 through 7 Pins 1 through 7 Pin function Digital I O and digital in External trigger in out Fault out Pins 1 through 2 Inhibit in Pins 3 Output couple Pins 4 through 7 Common connected to ground Pins 8 Front EKZ EZS Um 44 45 mm 1kW L 16 81 in 426 9 mm L 22 39 in 568 7 mm Ert d 3 468 in F E ront 88 mm 2kW UM 16 81 in 426 9 mm 3 Side 17 EN P L 24 928 in 633 2 m Figure 12 1 KW and 2 KW power supplies front and side dimensions 15 Keysight Advanced Power System N6900 and N7900 Series Power Supplies Brochure APS Ordering Information step 1 Determine performance level Choose the right APS power supply performance level to meet your power test needs
23. integrated features 9 When operated as standalone units APS power supplies can continuously sink up to 10 of their rated output current for an indefinite time With the addition of APS N7909A power dissipater units APS power supplies can continuously sink up to 100 of their rated output current This means you can sink the power supply s full rated output power for an indefinite time Note that the two quadrant sourcing and sinking capability of the DC power supply allows for continuous transitions between sourcing and sinking current without changing the power supply s output characteristics or introducing any disruptive behavior These capabilities make the APS an ideal solution for continuous source and sink testing needs in power storage applications For more information on the APS N 909A see page 8 Continuously source and sink current for power storage test applications TV E Load DC Source Quadrant Quadrant l A 100 lt 10 Figure 2 When you add N7909A power dissipater units to an APS supply you extend its ability to sink current from 10 to 100 of its rated current Voltage response APS ground reference APS sinking 1 current m mm m m m E m um m mmo Nm mm m o M eee Figure 3 shows an example of an APS power supply smoothly pulsing back and forth from sinking current at 10 A to sourcing current at 10 A Notice that the voltage level captu
24. lps you overcome a wide variety of power test challenges Power related test challenge Increasing test system throughput Reducing test time can mean big savings so achieving throughput gains is a never ending quest Building a continuous source and load You need a continuous source and load solution for testing power storage DUTSs ie 4 Protecting against power related damage When testing expensive DUTs designing protection from power damage in the test system is critical F Characterizing dynamic current profiles Your DUT has a current profile with a large dynamic range that you need to characterize J Generating power transients In harsh real world environments DUTs can face power transients such as Surges and interrupts To ensure proper operation of a design in the real world these transients need to be simulated in testing Characterizing inrush current You need to capture the large current surge that occurs when you first turn on power to your DUT with reactive elements at the input Maintaining output integrity under dynamic load conditions Maintaining a stable output voltage free of oscillations and voltage droop can be a challenge under a very dynamic load especially when working with long cable runs Tracking power events for root cause analysis You want to track power events during root cause analysis testing to see why or if you re DUT was damaged during test Me I E Properly powerin
25. oise CV rms 1 mV 1 mV 1 mV 1 mV 1 mV 2 mV 3 mV CV peak to peak 9 mV 9 mV 9 mV 9 mV 9 mV 30 mV 30 mV Load regulation Voltage 0 5 mV 0 75 mV 1 5 mV 2 mV 2 mV 4 mV w4 mV Current 8 mA 15 mA 3 mA 6mA 1 mA 2mA 1 mA 1 5 mA 0 8 mA 1 5 mA 1 mA 0 8 mA Volt programming and measurement accuracy Lead drop 1 V max 0 0396 1 mV 0 03 2 mV 0 03 4 mV 0 03 6 mV 0 03 8 mV 0 03 11 mV 0 03 14 mV Lead drop lt 25 of V rating 0 03 1 4 mV 0 03 3 mV 0 03 5 9 mV 0 03 9 mV 0 03 12 mV 0 03 17 mV 0 03 22 mV Curr programming and measurement accuracy 0 04 415 30mA 0 049648 15 mA 0 04 4 8mA 0 04 2 5 5 mA 0 04 2 4mA 0 04 2 5 mA 0 04 2 mA Current measurement low range accuracy 0 05 3 6 mA 0 05 1 2mA 0 05 0 6 1 2 mA 0 05 0 3 0 6 mA 0 05 0 25 0 5mA 0 05 0 4mA 0 05 0 25 mA Curr Measurement ranges High range N799x 225Ato225A 112 5Ato112 5A 56 2At056 2A 376410376A 28 1 Ato 28 1 A N A N A High range N797x 450 Ato 450A 225Ato225A 112 5At0112 5A 74 9 A to 74 9 A 56 2 Ato 56 2A 37 6At0o37 6A 28 1 Ato 28 1 A Low range N 95x 11 Ato 11A 5 5 A to 5 5 A 2 75 Ato 2 75 A 1 84 A to 1 84 A 1 37 A to 1 37 A N A N A Low range N797x 22 A to 22 A 11 Ato 11 A 5 5 A to 5 5 A 3 67 A to 3 67 A 2 7 5 Ato 2 75A 1 84Ato1 84A 1 37 Ato 1 37 A Transient response Recovery time 100 us 100 us 100 us 100 us 100 us 100 us 100 us Settling and 150 mV 150 mV 100 mV 150 mV 200 mV 300 mV 400 mV Volt up programming time 1096 to
26. power supply Each N 909A provides up to 1 kW of current sinking capability to an APS power supply so you will need two N7909As to achieve full two quadrant operation of a 2 kW APS supply You can use a single N 909A with a 2 kW APS power supply to achieve 5096 current sinking capability The N7909A form factor is 1U and full rack width N 909A connects to an APS power supply via a two wire power connection and a communication connection to provide continuous two quadrant operation The connections are located on the rear panel of both the N7909A and the supply as shown in Figure 7 m HALTI Mm M a penc M ll NN L rr r P a mn nn aa pe l I Ew Figure 7 N7909A power dissipater unit rear connections to a 1 kW APS power supply The N 909A does not operate as a standalone instrument It only works with an APS power supply Additional information on the APS s 2 quadrant operation The APS provides programmable current waveform capabil ity to fully utilize the two quadrant operation The APS provides current limit settings to ensure your de vice is operated in its allowable range By default the APS s current sink capability will perform down programming for pulling down voltage levels when it Is connected to loads with stored energy for instance loads with a large amount of parallel capacitance at their input All these capabilities are also available when you use a stand alone APS power supply s 1096 r
27. r l l power efficiency and storage calculations profile with advanced Additional APS measurement capabilities measurements Adjustable measurement intervals for both average and digi tized measurements Tine AFG provides simultaneous voltage aHa current External logging capability which simplifies data logging in ATE measurement capabilities that deliver high accuracy and software resolution Make measurements using two main modes Pre post and level triggering for pinpointing exactly where averaged or digitized In average mode the APS delivers high and when to measure accuracy DMM quality voltage and current measurements The digitizing capability allows you to capture dynamic current or voltage profiles at much higher resolution than an oscilloscope Capture inrush current APS provides an 18 bit current digitizer with a sample rate up to 200 kS s level triggers and a current measure ment range that is 2 25x as high as the max output current range of the power supply Accurately capture dynamic current profiles APS has two current measurement ranges that allow it to measure micro amps to amps The APS uses seamless ranging technology to transition from one measurement range to the other without discontinuities in the output power or in measurement data see Figure 1 05 Keysight Advanced Power System N6900 and N7900 Series Power Supplies Brochure Reduce ATE development time and support costs with
28. red at high resolution on the top trace remains constant with no glitches To complement the two quadrant operation all APS power Supplies have built in programmable output resistance capability This capability allows an APS power supply to simulate the internal resistance of a battery EE 0 Smart triggering In crease throughput protect your DUT and reduce test complexity The APS s smart triggering system provides trigger capabilities never before seen in a power supply The APS s smart triggering can accelerate your test throughput better protect your DUT and reduce the complexity of your test system The smart triggering system includes all the basic triggering functionality you would expect in a system power supply but it goes well beyond with capabilities such as Level triggering allows you to execute a trigger from five different APS measurement parameters voltage current power amp hour and watt hour Logical triggering gives you the ability to create logical and or and not trigger expressions using various trigger con ditions such as digital input pins level triggers status bits and more Triggers can be used to transition through a list of voltage or current levels as well as through the points of a voltage or current waveform Triggers with precision delays can be sent out from the APS after a voltage or current level change transient These triggers can be used to s
29. sting A one time event that steps the output voltage or current up or down in response to a triggered event Arbitrary waveforms An arbitrary waveform generator arb allows you to generate complex user defined voltage or current waveforms of up to 65 535 data points List A list can consist of up to 512 steps Each step in the list can have a unique dwell time associated with it which specifies the time in seconds that the list will remain at that step before moving on to the next step Lists can also be trigger paced in which case the list advances one step for each trigger received For a demonstration of the APS s arb capability an example interrupt pulse was generated with the N 9514A into a resistive load The interrupt pulse goes from 20 V to 2 V for 10 ms and then returns to 20 V The resulting interrupt pulse was captured Figure 4 and its fall time was measured to be 200 us Figure 5 For more information on the APS s output bandwidth and speed for generating voltage and current transients refer to the specifications section in this document or the APS user manual 10 ms pulse width AX 10 00000000ms 1 AX 100 00Hz AY 1 13 0000V Manual 1 v 50 0000ms 60 0000ms Figure 4 Voltage interrupt pulse generated by N7951A fal time 184 us Fall 184us 5 Source 24 Select Measure Settings Clear Meas Statistics 1 Fall Fall lt Figure 5 Interrupt pulse fall time measurement of lt 200 us
30. the N7908A BBR hardware option on an APS power supply 09 Keysight Advanced Power System N6900 and N7900 Series Power Supplies Brochure APS N7907A rack mount kit The N7907A rack mount kit can be used for all N6900 and N7900 power supplies regardless if they are 1 kW or 2 kW form factors It can also be used for mounting the N 909A N 907A APS rack mount kit is needed for every APS power supply or N 909A dissipater that you would like to mount The N 90 A is intended for use in a 19 inch EIA rack cabinet APS power supplies and power dissipater units can be mounted directly above or below each other without any worry of heat problems For installation instructions and other rack mounting options refer to the APS user manual at www keysight com find APS doc N7906A power assistant software The APS N 906A power assistant software is a free application that works with the APS power supplies The power assistant software provides three main capabilities for working with the APS power supplies Control an APS power supply using the Power assistant soft ware s intuitive graphical user interface Retrieve and view data from the optional APS power supply black box recorder see Figure 9 Perform trigger routing and conigure logical trigger expres sions see Figure 10 The power assistant software is available for download at www keysight com find powerassistant For more information on the APS power assistant software

Download Pdf Manuals

image

Related Search

Related Contents

Manual als PDF - Tommys  Supermicro Superserver 5036I-IF  Demande de qualification de la relation de travail  ASR-X User's Guide - Platinum Audiolab  Hoefer HE-PLUS  Honeywell RTH6350D Use and Care Manual  manual - Jacmoto - Capas protetoras para motos, scooters e  MODE D`EMPLOI SIMPLIFIÉ D`ORPHY GTS II ET REGRESSI  Triarch x 25764 User's Manual  iSleep 20+ - CPAP Australia  