Home

APOLLO S-120AM USER`S GUIDE

image

Contents

1. 3 230 Vac option Frequency 50 Hz 0 1 crystal control 60 Hz option Wave form Modified sine wave Charger mode Nominal 12 Vdc Max charge current 10A SYSTEM Inverter maximum efficiency 8096 at full load Pf 1 Low battery disconnect 10 3 11 0 Volt pre adjust PROTECTION Over temperature Overload Short circuit Reverse PV polarity Transient voltage Over charge Over discharge INDICATOR Solar Charger Status Boost charge green Charging green Battery level Full Battery green Medium Battery yellow Low Battery red Inverter Status Inverter normal green Alarm red ALARM LED Low battery Overload Short circuit Over temperature VENTILATION Fan Automatic control OPERATING Temperature 0 45 C CONDITION Relative humidity 0 95 non condensing DIMENSION WxHxD cm 16 5 x 29 5 x 9 6 WEIGHT Approximate in kg 5 5 Continuous product development is our commiment In that manner the above specifications may be change without prior notice
2. batteries and all sec tions of this user s guide For your safety all cables should be wired in the suitable size conduits 4 1 Installation 4 1 1 Turn off Power switch and turn off all breaker 4 1 2 Connect grounding wire at the PE EARTH e position by using copper wire sizing in Figure 1 4 1 3 Connect battery cable from positive battery to positive terminal at rear panel and negative battery to negative terminal at rear panel through battery circuit breaker 4 1 4 Connect PV cable from positive PV array to positive terminal at rear panel and negative PV array to negative terminal at rear panel through PV circuit breaker 4 1 5 Plug in AC loads at AC Output receptacle 4 2 Start up Procedure 4 2 1 Turn off all AC loads that connected to APOLLO S 120AM series 4 2 2 Turn on battery breaker and PV circuit breaker respectively 4 2 3 Turn on the power switch after the INVERTER indicator is lit 4 2 4 Turn on AC loads that connected to APOLLO S 120AM series 4 3 Shut down Procedure 4 3 1 Turn off all AC loads that connected to APOLLO S 120AM series 4 3 2 Turn off the power switch 4 3 3 Turn off PV circuit breaker and battery circuit breaker respectively TROUBLESHOOTING If the inverter does not operate properly and you cannot solve the problem using the troubleshooting information in this users manual please contact your LEONICS local distributors LEONICS Service Center send e mail to su
3. M USER S GUIDE rel LEONICS STAND ALONE INVERTER with MPPT CHARGE CONTROLLER CONTENT SAFETY INSTRUCTIONS INTRODUCTION FRONT AND REAR PANEL INSTALLATION AND OPERATION TROUBLESHOOTING SPECIFICATIONS ON AWW SAFETY INSTRUCTIONS Please read and follow this user s manual carefully and completely Important Please keep this user s manual for later reference It consists of Introduction Front and Rear Panel Installation and Operation and Troubleshooting If the inverter does not operate properly and you cannot solve the problem using the troubleshooting information in this user s manual please contact LEONICS local distributors LEONICS Service Center send e mail to support leonics com or visit www leonics com To help you much more quickly when contact us please record the following information LEONICS APOLLO model Serial number Purchased date Purchased from WARNING Risk of electric shock DO NOT remove cover No user serviceable part inside please refer servicing to qualified service personnel 1 1 Electrical Safety 1 1 1 1 1 2 1 1 3 1 1 4 Do not work alone where there are electrically hazardous conditions Contact with live conductors will cause burns and dangerous electric shock Only qualified electricians should install or service this unit PV panel and batteries Properly install and ground e the equipment in accordance with the ins
4. exposed to sunlight a shock hazard exists at the output cables or exposed terminal To reduce the risk of shock disconnect the array or cover it with an opaque cloth or material before making electrical connec tions or servicing the system Ensure correct polarity connection of PV panels 1 4 Safety Instruction when working with battery 1 4 1 1 4 2 1 4 3 1 4 4 1 4 5 Ensure the area around the battery is well ventilated Never smoke or allow a spark or flam near battery Be extra cautions to reduce the risk of dropping a metal tools onto battery It might spark or short circuit battery or other electrical parts that may cause an explosion Remove all metal items like rings bracelets and watches when working with batteries Have someone within range of your voice or close enough to come to your aid when you work near battery INTRODUCTION APOLLO S 120AM series is a compact high efficiency solar charger built in stand alone inverter controlled by microprocessor Inverter is used for transforming DC power to AC power in order to supply AC loads Solar charger will charge battery when DC power from PV is detected with 3 stages charging And built in MPPT Maximum Power Point Track ing to maximize power generated by PV Features Microprocessor Control Short circuit Overload Overcharge and Overdischarge Protection Quick and smart charging for battery Reverse polarity protection for PV LED indication B
5. pport leonics com or visit www leonics com SYMPTOMS CAUSE SOLUTION ALARM indicator is lit red Short circuit of AC loads APOLLO S 120AM inverter is fault Check AC cable connected to APOLLO S 120AM series Consult service center INVERTER indicator is lit but there is no AC power from AC outlet The inverter is overloaded and shutdown itself overload shutdown condition Turn off AC loads and inverter follow item 4 3 Disconnect some loads the restart again follow item 4 2 The power switch is on but inverter does not operate or INVERTER NORMAL is off Battery voltage is too low until the inverter can not operate Low battery shut down condition Turn off the power switch and restart again and wait until the INVERTER NORMAL indicator is lit or the inverter start battery charging ALARM indicator blink slowly Over temperature condition Ensure that sufficient ventila tion is provided Ensure that the ventilation fan at the rear side work properly SPECIFICATIONS MODEL S 120A M37 S 120A M59 INPUT Inverter mode Nominal voltage 12Vdc Voltage range 10 16 Vdc Charger mode PV maximum voltage 70 Vdc 92 Vdc MPPT tracking voltage 26 70 Vdc 40 92 Vdc OUTPUT Inverter mode Power continuous 150 VA 150 Watt Max surge power 20096 of continuous power Voltage range 220 Vac
6. reen yellow red Full battery lit off off Medium battery off lit off Low battery off off blink Table 3 Indicator Lights and Inverter Status STATUS INVERTER indicator green ALARM indicator red Inverter is operating lit off Over temperature slow blink Low battery alarm blink Overload alarm quick blink Inverter fault alarm lit 3 2 Rear Panel 3 2 1 3 2 2 Oo e POWER FUSE OUTPUT SS SS T SS 9 m 3 2 3 Oc o piede 3 24 3 2 1 POWER SWITCH Switch for turn on off APOLLO S 120AM series 3 2 2 FUSE A safety component for protect system from overload or battery short circuit 3 2 3 TERMINALS The terminal for connecting to ground PV and battery see Installation and Operation 3 2 4 OUTPUT Plug receptacles directly connect to AC loads INSTALLATION AND OPERATION om 0 POWER FUSE OUTPUT e on E SSS B SS a o B I OFF D gt AC LOAD 2 Q 220Vac 50Hz 2 5 mm Modify Sine O o g om o Ircui Battery E Circuit Circuit Breaker Breaker 40A 2P 16A 2P Figure 1 Sample of connection diagram is shown above Before installing or using this unit read all instructions and caution markings on this unit PV panel
7. truction manual Periodically check your cable terminal and power source to make sure that they are in good condition To reduce risk from electric shock disconnect all power source before connecting disconnecting the batteries or loads or when maintaining or servicing this unit 1 2 Safety instruction for installation and operation 1 2 1 1 22 1 2 3 1 2 4 1 2 5 1 2 6 Before installing or using this unit read all instructions and caution markings on the charge controller PV panel battery and all sections of this user guide Install this unit in a temperature and humidity controlled indoor area with adequate air flow and away from chemical particles or flammable substances Avoid installing the unit near radio transmission station heat dissipation equip ment and direct sunlight This unit has ventilation grills Ensure that sufficient ventilation is provided DO NOT block the ventilation grills Use insulated tools to reduce your risk of electric shock Remove all jewelry or other metal objects such as rings necklace bracelets and watches when installing this product Do not install this unit directly above the batteries or in the same compart ment as vented batteries Batteries generate gas which is corrosive to electronic equipment 1 3 Safety instruction for PV panel 1 3 1 1 3 2 1 3 3 Before installation please read instruction books or user s manual for PV panel and system Whenever PV array is
8. uilt in MPPT Maximum Power Point Tracking FRONT AND REAR PANEL LEONICS APOLLO S 120AM www leonics com c STAND ALONE INVERTER WITH MPPT SOLAR CHARGE CONTROLLER www leonics co th lelelelele InSovUs sIlUdIdioS SOLAR CHARGER BOOST CHARGE aie ULUALAATLAN Q a uuALAAT iauna m ae E 4i ITI y A inSooiUaons iaul h INVERTER P INVERTER ANULUA NORMAL Zire uia Lastiauna O ALARM 3 1 Front Panel 3 1 1 3 3 1 2 1 3 1 2 2 3 1 1 SOLAR CHARGER show solar charger and battery status 3 1 1 1 BOOST CHARGE APOLLO S 120AM series is operating in boost charging mode 3 1 1 2 CHARGING battery 3 1 1 3 Battery Level APOLLO S 120AM series is charging the The indicator light show the full medium and low battery level 3 1 2 INVERTER show inverter status 3 1 2 1 INVERTER NORMAL 3 1 2 2 ALARM conditions Table1 Indicator Lights and Charging Status Inverter is operating The APOLLO S 120AM series is in abnormal STATUS BOOST CHARGE indicator green CHARGING indicator green Bulk charging off lit Boost charging blink on 1 4 sec off 0 2 sec blink on 1 4 sec off 0 2 sec Float charging off blink on O 8 sec off 0 8 sec Not operating off off Table 2 Indicator Light and Battery Status STATUS first indicator second indicator third indicator g