Home
Technical manual for Multi Apartment Gateway 1456B
Contents
1. STATIC IP ADDRESS 192 168 1 200 default FIXED POE SETTABLE POE NON POE 192 168 0 X ROUTER 192 168 0 1 Installer PC interface A must be assigned a new Static IP address belonging to the same network as the devices connected to interface A PERFORM A DHCP SYSTEM SCAN AND ASSIGN A VIP ADDRESS Follow the procedure below to perform a system scan in DHCP to locate all the devices connected to interfaces A and B address will be automatically assigned to the devices in addressing mode Autoip connected to interface e IP address will be automatically assigned to the devices in addressing mode DHCP connected to interface if the system is connected to a server with the DHCP function active e devices with Static IP address will be identified only if they have a network address that is compatible with that of interface A iL Bee aoin 5 Local ScanSystem Selective T Tel Device Groups T Scan Name Device type ViP address IP address Device List Options General Remote Connections Connessione 1456B Impianto UTCE AN IP COMPATIBLE WITH THE SYSTEM WILL BE ASSIGNED TO THE PC E G 192 168 1 30 SYSTEM SCAN IN DHCP Installer PC lt BACK 1 From Options a Local connections b tick DHCP Enable c and confirm d L Wl Output Window aM NE o Sw Y Filter
2. EE f amp P 11 Wee 4 0 Synoptic C Local Scan System Selective Download Restart Group Configure SendMessage SER 12 Device Groups Scan Firmware device Devices Messages Navigation Tree Name Device type ViP address IP address 1456B Device List 14568 App connection settings 1456 Third party module 00123459 UTcE Planux H264 00000028 9 i Switchboard 00001003 92 1 IP address Smart H264 00000005 92 1 address 316 H264 00000103 92 1 Local UDP port 64100 64100 Description Local address 192 168 1 200 192 168 1 200 Local TCP port 64100 64100 Remote address nome host4 comelitdns com Main Settings Remote TCP port 64100 Apartments App connection settings Remote UDP port DynDNS Licenses Video connections Message server SIP phone lines SIP settings Maximum video connections on tunnel App Users Maximum video connections on net Read page Clear A Warnings Messages Show Last Time Description 15 06 2015 11 01 51 Start scan 15 06 2015 11 02 20 Start scan lt BACK 17 Connection to the configuration web pages From the web pages you can perform all of the operations available on ViP Manager except license activation The backup and restore function is only available on the web pages 1A Remote connect
3. 4 Warnings Messages Show Last Time Description 15 06 2015 11 01 52 Scan completed Found 0 device s 15 06 2015 11 02 20 Start scan o 15 06 2015 11 02 21 Scan completed Found 0 device s 15 06 2015 11 02 36 Start scan In main settings Licenses 9 you can view all the licenses installed h amp Manager Local Online 7 52 SoH X 55 Synoptic 975 sre Local Scan System Selective Download Restart Addlicense Configure Send Message TE Device Groups Scan Firmware device brena Messages Navigation Tree Name i ViP address 1456B ll Device List 14568 Information Licenses 14566 Third party module 00123459 192 168 1 65 i Planux H264 00000028 192 168 1 54 Switchboard 00001003 192 168 1 64 Description UTCE Smart H264 00000006 192 168 1 56 UTCE 316 H264 00000103 192 168 1 55 Main Settings Addressing Apartments App connection settings DynDNS Message server SIP phone lines SIP settings Users lt BACK 8 LICENSES AVAILABLE FOR PURCHASE EXAMPLE APARTMENT WITH MASTER LICENSE AUDIO TELEPHONE BACKUP INTERNET Moma YES 65 NETWORK DATA AVAILABLE xComelit SIP PROVIDER it is possible to add internal units in Slave mode EXAMPLE APARTMENT WITH SLAVE LICENSE AUDIO TELEPHONE BACKUP VES NETWORK DATA AVAILABLE
4. TECHNICAL MANUAL 40 56 Cornnelit Technical manual for Multi Apartment Gateway 1456B 4 amp Cornelit Passion Technology Design Article 14568 is multi apartment gateway that can serve up to 200 apartments with a maximum of 15 slave devices per apartment can answer calls from a external unit via a virtual door entry monitor App for smart phone tablet or using a normal GSM or landline telephone incorporates the SIP protocol to enable telephone calls via SIP server or via virtual lines purchased from a SIP services provider allows up to 4 simultaneous audio video calls can be configured remotely from a web page Description of Art 1456B NO oO FB OND A d SOLO CON CAVO ROSSO COMELIT 2E7T000500 zT ONLY WITH COMELIT RED CABLE 2E7T000500 FIXED POE Al Ethernet port for system riser input default addressing Autoip Dip switches for the procedures Reboot with predetermined network settings on page 19 and Restoring factory settings on page 20 Power supply input via Art 1441 Art 1441B CV1 and CV2 for setting port A2 CV3 and CVA for setting port A3 A4 non POE Ethernet port for PC or router connection default Static IP address 192 168 1 200 netmask 255 255 255 0 non POE settable Ethernet port POE default Static IP address 192 168 1 200 netmask 255 255 255 0 Set the port as POE if you wan
5. _ ONLY WITH COMELIT RED CABLE 2E7T000500 ONLY WITH COMELIT RED CABLE 2E7T000500 ONLY WITH COMELIT RED CABLE 2271000500 STATIC IP ADDRESS 1 STATIC IP ADDRESS 192 168 1 200 default 192 168 1 200 default SYSTEM ROUTER ROUTER with active with active internet connection internet connection Installer PC Installer PC with Manager with ViP Manager version 2 3 0 and higher version 2 3 0 and higher Take particular care with regard to the network All system devices form part of a single network so it it is A interface settings and do not configure interfaces A only necessary to configure interface A and B with the same addresses or similar parameters In this case DO NOT alter the configuration of interface B each IP address must be unequivocal the addresses of the interfaces A and B must not belong to the same subnet lt BACK 3 2 Manager addressing default address of the device 192 168 1 200 belonging to the same router network e g 192 168 1 1 ONLY WITH COMELIT RED CABLE 2E7T000500 M STATIC IP ADDRESS 192 168 1 200 default 192 168 1 X ROUTER 192 168 1 1 Installer PC CASE 1 lt Comelit default address of the device 192 168 1 200 NOT belonging to the same router network e g 192 168 0 1 A ONLY WITH COMELIT RED CABLE 2E7T000500 F
6. Comelit SIP PROVIDER it is possible to add internal units in Slave mode EXAMPLE APARTMENT WITH TELEPHONE LICENSE SLAVE DOOR ENTRY MONITOR OPTIONAL SIP PROVIDER itis possible to add internal units in Slave mode BACK 9 4 amp Cornelit 4 DynDNS configuration for remote connection The DynDNS adaress Dynamic DNS allows a DNS name to be permanently associated with the IP address of the same host even if that address subsequently changes A DynDNS must be registered in order to make the 1456B accessible from a remote web page and to allow operation of the Comelit ViP remote application V An active internet connection is required to complete the license activation procedure Select article 1456B and select Main Settings DynDNS a Select ComelitDNS b in order to use the free ComelitDNS service Press Register CDNS c to register a ComelitDNS hostname Complete the registration panel NB make a note of the data entered or copy and paste them directly into the configuration page and press to complete the registration Enter the hostname user name and password in the DynDNS settings screen of the Manager software d 6 Press Write page e to confirm the current settings A OND Manager Local Online File Home EME amp Q AK FS Local Scan System Selective Download Restart Group Addl
7. 64100 1 65535 External Ending Port 64100 1 65535 vf Use the same port range for Internal port Internal Starting Port 64 00 1 65535 Internal Ending Port 64100 Internal IP address 192 fies 1i _ 200 BACK 11 Comel lit 6 SIP settings configuration The SIP settings configuration procedure is only to be used when you wish to channel a door entry phone communication to a SIP digital telephone line PSTN GSM It is possible to purchase up to 15 SIP phone lines to be shared between all the apartments Each phone line is a communication channel when a call is received from an external unit to landline or mobile phone the first available SIP line is used Purchase the desired number of SIP phone lines max 15 from a SIP services provider each phone line is a valid account A on the SIP server used to make telephone calls the user settings and password are to be entered in the SIP settings screen see page 13 1 Select the device 1456B and select Main Settings SIP settings a 2 Enter the IP address of the SIP service provider for example sip messagenet it and the UDP port of the server supplied by the service provider for example 5061 b 3 Leave the parameter Codec preference c for audio encoding decoding on the default setting PCMA PCMU US users only select the codec 4 Press Write to save the current settings
8. Add license b 3 Press Add license file s c 4 Look for license files with the extension viplcs d on the USB storage device if supplied at time of purchase or from the folder where it was saved when purchased and confirm by pressing Open e anew line with the newly installed licenses will appear in the license activation wizard window 5 Repeat steps 3 and 4 to install other licences 6 Press Next f T enter a valid email address press Next and confirm Device List Wl Output Window Synoptic Filter Window p 27 Local Scan System Selective Download Restart Group Add licen Send Message 5 Options E Device Groups Scan Firmware device Devices Navigation Tree Name Device type ViP address IP address 1456B Device List a Information 1456G Third party module 00123459 192 168 1 65 idressi IP address 192 168 1 200 i TE Planux H264 00000028 192 168 1 54 ViP address 41111112 Switchboard 00001003 192 168 1 64 UTCE Smart H264 00000006 192 168 1 56 UTCE 316 264 00000103 192 168 1 55 License activation Select license file s Search COMELIT E License code Device licenses recent documents Documents you can select more than one file at a time Computer resources Filename Network resources File type Create Pdf Cear
9. Manager Local Online Device List IR Am 7 Output Window amp i o B im 55 Synoptic 07 Y Filter Window Local scan Syste e Download Restart Group Addlicense Configure Send Message Options Firmware device Devices Messages Navigation Tree ViP address IP address 1456B e Device List Information address Third party module 00123459 1 Addressing FEN Planux H264 00000028 ViP address 11111112 a h Switchboard 00001003 IP address Smart H264 00000006 92 1 9 316 264 00000103 Description Reset pace lt lt Comel lit 3 Licence activation Activation of the licenses for each apartment allows the users of that residential unit to use the special functions provided by the device 1456B see page 9 for further information about licenses e remotely answer an audio video call from an external unit using a smartphone or tablet master and slave license e answer an audio call from a GSM or landline telephone all licenses e perform an audio telephone backup of an unreachable device master and slave license the possibility to dispense with a master internal unit master license v An active internet connection is required to complete the license activation procedure A license is needed for each apartment that wishes to make use of the functions described above 1 Select device 1456B a 2 Press
10. ROUTER 192 168 1 1 100 240 INTERFACE B INTERFACE A AUTO IP IP 192 168 1 X ORANGE WIRE TX WHITE ORANGE WIRE TX GREEN WIRE RX 120 230 V 120 230 V n 22 sez 4 N 4851485 1 24 24 159097 10 0 Vac 4682 33436 4682C 3360A zz F 88 lt 21 amp Cornelit gt z 0 lt zo 6304 I O m O E 6202W amd D 1 gt 1440 g0 ouToutouTou ou in 0 F BM 172 3 4 anga zn VINAPAVAT vial 7 6231 00000000 192 168 1 1 INTERFACE IP 192 168 1 X 1441 1441 gt E IN lou bu E E 1000 o m AN 100 240 100 240 V ORANGE WIRE TX ORANGE WIRE WHITE ORANGE WIRE WHITE ORANGE WIRE TX GREEN WIRE RX GREEN WIRE RX WHITE GREEN WIRE RX WHITE GREEN WIRE RX 120 230 V 120 230 R 5 485485 lt 24 24 Ce G p 2 2 3360A 4682C 33436 I lt BACK 2
11. Window Read Barcode Options b meros Local Connections A v 2 Navigation Tree Name Impianto UTCE Network interface Intel R PRO Wireless 2200BG Netw v Refresh DHCP enable IP address Subnet mask Default gateway lt Comelit 2 Launch the system scan by pressing Scan System e all the devices connected to the system will be displayed in the device list 3 Select device 1456 B f select Addressing ViP address g assign an unequivocal ViP address to the device h and press Write page i to save the current settings CASE 1 Manager Local Online Ris AGE 2 i Bb Pp 5 2 lll Output Window 2 59 Synoptic Y Filter Window JF fio z Local Scan Syste pelective Download Restart Group Addlicense Configure Send Message 12 Device Groups EXE Options Scan Firmware device Devices Messages Navigation Tree ViP address 1456B Information Device List ViP address Third party module 00123459 192 168 1 Addressin Planux H264 00000028 192 168 1 ViP address 11111112 nunp Switchboard 00001003 192 168 1 IP address Smart H264 00000006 192 168 1 9 316 H264 00000103 192 168 1 Description Main Settings reset ove In the case of system with 2 14568 devices it will be necessary to assign to interface A of one of the two devices a new Static IP address as described i
12. sec red 1 sec green 5 Return all the dip switches to OFF aor gt The green LED will flash 5 seconds ON The device will start with the default network settings 6 At the next restart the device will recover the saved settings lt BACK 19 Restoring factory settings lt Comelit This procedure allows you to restore all the factory parameter settings and to delete all the device configurations V With the dip switches in the default positions OFF 12 Switch off the power supply to the device OFF Set the dip switches to ON Wait 20 40 seconds until the LEDs start flashing rapidly and alternately 0 1 sec red 0 1 sec green 2 3 Power on the device 4 5 Return all the dip switches to OFF OFF gt The red LED will flash for 5 seconds ON 12 The device will reset all parameters to the factory settings and restart in the normal way WARNING the full reset procedure also deletes and the licenses installed on the device You can restore the licenses max 2 times using the procedure described in the following paragraph Restoring licenses The following procedure allows you to restore licenses lost during the full reset procedure Select the device 1456B a Press Add license from the main menu b Press Load from server to restore previously activated licenses c PB o mu From ViP Manager look f
13. user ID The procedure for phone lines configuration is described below 1 Select the device 1456B and select Main Settings SIP phone lines a 2 For each SIP phone line purchased enter the respective username and password b 3 For each SIP phone line purchased enter the user ID c only if this has been provided by the SIP services provider otherwise leave the field blank 4 Press Write page d to save the current settings Manager Local Online s Device List dm ae 9 amp e amp o AP Local Scan System Selective Download Restart Group Add license IE Device Groups 5 Firmware device Devices Device type ViP address IP address 1456B Device List 13568 Information 1456c Third party module 00123459 192 168 1 65 Planux H264 00000028 192 168 1 54 8 Switchboard 00001003 192 168 1 64 Description i UTCE Smart H264 00000006 192 168 1 56 316 264 00000103 192 168 1 55 Settings Apartments App connection settings DynDNS Licenses Message server SIP phone lines SIP settings Users A maximum of 15 SIP phone lines may be enabled 24 Configure Send Message Messages SIP phone lines Page Help Output Window e Y Filter Window Options 2 Navigation Tree If the username the password and the user ID supplied by the SIP services provide
14. 2 lt Comelit Glossary Autoip Automatic Private IP Addressing known as APIPA or Auto IP is a method for automatically assigning IP addresses to the devices connected to the network Dynamic DNS Dynamic DNS is a technology that allows a DNS name to be permanently associated with the IP address of the same host even if that address subsequently changes e DHCP In telecommunications and information technology Dynamic Host Configuration Protocol DHCP is an application layer network protocol that enables the devices or terminals of a local network to automatically receive on each request to an IP network i e the internet the necessary IP configuration to establish a connection and operate on a wider network based on Internet Protocol i e to interact with all the other subnets exchanging data provided that they are also integrated in the same way with the IP protocol Gateway a gateway is a network device that operates at network level and above of the ISO OSI model It s main function is to transport network data packets outside a local network LAN Gateway is a generic term for a service that sends data packets outside of the network the hardware device that fulfils this task is usually a router Simpler networks have just one gateway that sends all outbound traffic to the Internet network More complex networks have several subnets each of which refers to a gateway which routes data traffic to other subnets or redir
15. 68 1 2 so that the two devices are able Subnet mask 255 255 255 0 to communicate IP address 192 168 1 2 93 Default gateway lt BACK 9 amp Cornelit Launch the system scan by pressing Scan System e the 1456B will appear in the device list f 4 In Addressing IP address g assign device 1456B a Static IP address h and a IP netmask i compatible with the system for example IP 192 168 0 5 netmask 255 255 255 0 warning the IP address must not already be in use 5 Enable Use default gateway I ONLY for the interface connected to the router interface A by default 6 Set the gateway address m for example 192 168 0 1 press Write page n to save the current settings CASE 2 Manager Local Online File Home Rit A Cl se Device List s a d 18 Pp R 4 55 Synoptic Local Scan Syste Download Restart Group Addlicense Configure Send Message Device Groups Scan Output Window Y Filter Window Options Navigation Tree Firmware device Devices Messages ViP address IP address Name Device type Ga Device List f 14568 14568 14568 11111112 192 168 1 200 Information A Network Interface 4 ports IP address mode Static Addressing IP address 192 168 1 200 address IP netmask 255 255 255 0 Description Use default gateway Main Settings Gateway address 192 168 1 1 B Netwo
16. ViP Manager Local Online amp x Device List ET E Wl Output Window d Rit ft GCE 5 diea e gt EN 55 Synoptic 9 Y Filter Window 4 Local Scan System Selective Download Restart Group Addlicense Configure Send Message Options a r ES TE Device Groups Scan Firmware device Devices Messages Navigation Tree Name Device type ViP address IP address 1456B 5 Device List Information 14568 SIP settings 4 Thi l 34 92 168 1 1456c ird party module 00123459 192 168 1 65 i UTE Planux H264 00000028 192 168 1 54 SIP Server IP Hostname Switchboard 00001003 192 168 1 64 Description SIP Server port UTCE Smart H264 00000006 192 168 1 56 316 H264 00000103 192 168 1 55 Main Settings DTMF open relay 1 Apartments DTMF open relay 2 App connection settings DynDNS DTMF open relay 3 Licenses Codec preference Message server Page d Read page DTMF open relay 1 2 3 sequence of keys to press minimum 3 maximum 6 to send a command to activate the relay from a telephone the default values can be changed lt BACK 12 7 SIP phone lines configuration lt Comel lit Access to SIP phone lines is controlled by the username and password supplied by the SIP services provider at the time of purchase Some providers also provide a User ID which be variously designated User authentication user auth or
17. ects it to other gateways Dynamic IP address dynamic addresses are used to identify non permanent devices in a LAN A server in the LAN automatically dynamically assigns the address selecting it a random from a preset range You can select the range of addresses in accordance with the number of users by setting the netmask i e by telling the DHCP server how many address bits can be assigned dynamically to each single client that accesses it For example if the netmask has the value 255 255 255 0 where each block of numbers separated by a point denotes a group of 8 bits only the last 8 bits can be assigned to the hosts e Static IP address static addresses are used to identify semi permanent devices with a permanent IP address Network servers printers etc typically use this addressing method Static addressing is generally used in preference to dynamic addressing for non permanent network devices if there is a limited number of hosts in the subnet and or for security reasons so that the actions of each host and the relative user can be kept under control Public IP address in telecommunications and information technology a public IP adaress is an IP address in the address range of the internet network that is unequivocally allocated and is potentially accessible from any other public IP address and therefore can be used for addressing and routing via IP protocol POE Power over Ethernet PoE the acronym is a technique fo
18. er having to press a video request button lt BACK 15 lt Comelit 10 Message server configuration The following procedure describes how to specify on the 1456B the IP address of the 1952 device to be used as a message server if present 1 Select device 1456B and select Main Settings Message server a 2 From the pull down menu b select ViP address or IP address and enter the address of the CPS device that is to be used as a message server 3 Press Write page c to save the current settings Manager Local Online 2 amp 02 5 Device List 14568 14566 im i UTCE i BACK Device type Third party module Planux H264 Switchboard Smart H264 316 H264 lel Device Groups amp 4 75 Synoptic address IP address 00123459 00000028 00001003 00000006 00000103 Local Scan System Selective Download Restart Add license Configure Send Message Scan Firmware device icis Messages Navigation Tree 1456B Information Message server Addressing b Description Main Settings Apartments App connection settings DynDNS Licenses Message server phone line amp Cornelit Special configurations App connection settings From the following configuration page you can e set personalised parameters for the app connection fo
19. gure Send Message x Options Device Groups M Scan Firmware device Devices Messages Navigation Tree Name Device type ViP address IP address 1456B 5 Device List 14568 Select apartment 1456c Third party module 00123459 192 168 1 65 Planux H264 00000028 192 168 1 54 Apartment i Switchboard 00001003 192 168 1 64 Description 8 Smart H264 00000006 192 168 1 56 Users 316 H264 00000103 192 168 1 55 Enable Device type Description Phone number Backup Backup of Apartments Disabled App connection settings Enabled App App Mary Disabled DynDNS Enabled Phone John Phone Enabled 1 Message server SIP bun lues Disabled Disabled SIP settings Disabled Disabled Users Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Page Help d Read page Slave ID of the device Each apartment supports 15 devices which are assigned a device ID slave number that identifies the device within the apartment The device ID assigned in this page must correspond to that assigned to the same device in the page Addressing ViP address It is advisable to assign the slave numbers 1 2 3 to devices that can receive the video signal internal units applications so that during a call they can receive the video signal directly without the us
20. ic Y Filter Window 82 320 Local ScanSystem Selective Download Restart Group Addlicense Configure Send Message zi Options IE Device Groups Scan Firmware device Devices Messages Navigation Tree 1456B lll Device List 14568 Information Apartments 14566 Third party module 00123459 192 168 1 65 8 Enable address i Planux H264 00000028 192 168 1 54 il UTCE Switchboard 00001003 192 168 1 64 Description i UTcE Smart H264 00000006 192 168 1 56 316 264 00000103 192 168 1 55 Main Settings ioaren App connection settings DynDNS Licenses Enabled 00000003 John Smith Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Y Message server SIP phone lines SIP settings Users oon Dm AUN Read page lt BACK 14 lt Comelit 9 Users configuration devices In this page you can configure the slave devices that can be activated for each apartment max 15 Each device is identified by its slave number Each device must be assigned a type internal unit app or telephone a description the phone number the case of a telephone mobile phone 1 Select device 1456B and select Main Settings Users a 2 Select the apartment for which you wish to configure the users b 3 Configure the individua
21. icense Configure Send Message 5 E Device Groups Firmware device Devices Messages Navigation Tree Name ViP address IP address 1456B 5 Device List 5 2 168 1 20 Information 11111112 DynDNS settings Third party module 00123459 192 168 1 65 keni Planux H264 00000028 192 168 1 54 DynDNS provider Switchboard 00001003 192 168 1 64 Description Smart H264 00000006 192 168 1 56 316 H264 00000103 192 168 1 55 Main Settings Hitan Hostname Apartments App connection gaat DDNS code Password Comelit DNS Product registration Hostname Email address Password Confirm password have read the service terms and conditions Comelit DNS registration form BACK 10 4 5 Port Forwarding setting for remote connection Port forwarding is the operation that allows the transfer of data from one device to another a specific communication port This procedure enables an external user mobile phone to access a device on a local network 14568 The procedure for opening router ports for the article 1456B is required in order to allow remote access to the system via a web page port TCP 8080 and via an App port TCP 64100 port UDP 64100 For some internet service providers port 64100 is not available In this case try changing the address of the port with one of the following 25 80 110 143 or call your interne
22. ion 1B Local connection Once the DynDNS configuration has been completed see v With the PC connected via Ethernet cable to interface A of page 10 and port 8080 see page 11 on the router has art 1456Ba and IP address belonging to the same network been opened remote access of the device will be possible as interface A AN active internet connection is also required 1B Enter the IP address of interface A as in the following 1A Enter the registered hostname or the public IP address as in example and press enter the following examples and press enter http registered hostname comelitdns com 69 8080 http Interface A IP address 8080 example nome host3 comelitdns com default 192 168 1 200 http nome_host3 comelitdns com 8080 Or http public IP 8080 example 213 149 219 88 Xhttp 213 149 219 88 8080 2 Login 1 Press Login a 2 Enter the installer password default comelit and conform by pressing Login b xComelit Comelit 1456B Login amp Cormelt Index Login cum PASSW OR p 2015 by Comelit S p A All rights reserved Version 1 3 3 Uptime 0 days 04 38 09 Used mem 27 90 MB English lt BACK 18 lt Comel lit Backup and restore The backup function allows you to save the current configuration which can then be subsequently called up at any time using the restore function The backup and
23. l devices max 15 per apartment c e Enabling enable disable the device for the apartment by selecting Enabled Disabled Device type assign the type of device choosing between e Internal unit Comelit internal unit e App Remote App for Android or Apple devices consult the relative manual for further details e Phone virtual device controlled by the 14568 and used to make phone calls to a landline or mobile phone Description Description enter a description to identify the device Phone number if you are configuring a telephone enter the phone number of the device Backup enable disable the backup line to configure the current device as a backup unit to which failed calls to the device specified in the adjacent column Backup of are to be forwarded Backup of specify the device to be backed up by selecting the corresponding slave device Backup example the slave 3 phone number John Phone is enabled as the backup unit of the App slave 1 John App installed on the same device If the App John App cannot be reached after a few seconds the call will be redirected to the phone number John Phone 4 Press Write page d to save the current settings viP Manager Local Online 55 omea s e e E P 5 4 Output Window 5 g Y Filter Window 4 E O Local Scan System Selective Download Restart Group Addlicense Confi
24. n case 2 as each device must have a unequivocal IP address ASSIGN TO INTERFACE A A NEW Siatic IP address The following procedure describes how to assign network settings to the device1456B that are compatible with those of the devices connected to interface A CASE 2 1 Open the software ViP Manager version 2 3 0 or later downloadable from the website www comelitgroup com 2 From Options a Local connections b untick the DHCP enable box and assign an IP address to your PC c in the example 192 168 1 2 that belongs to the same network as the IP address of interface A default 192 168 1 200 and confirm d the last value must be within the range of 2 to 253 excluding 200 assigned to the gateway Art 1456B and the values already assigned to other devices connected to the network Binneas C A OST AK Ter Options LN z 5 amp Local Scan System Selective Download Restart Group Addlicense Configure Send Message IE Device Groups Scan Firmware device Devices Messages Navigation Tree Name Device type ViP address IP address 5 Device List Options a Local Connections Remote Connections Messages Connessione 14568 Impianto UTCE Assign to the PC an Advanced Impianto UTCE Name Language IP address that 15 Network interface Intel R PRO Wireless 2200BG Netw Refresh compa tib le wi t h t he DHCP enable network of the 1456B e g 192 1
25. or the device 1456B as described in the ViP Manager addressing procedure page 4 A Licenses can be restored a maximum of two times only For additional license restore operations contact Comelit technical assistance amp 4 O figure Send Message Fam Local Scan System Selective Download Restart Group 5 Device Groups 5 Firmware device Devices Device List ON am ou gt X Output Window 555 Synoptic Add license Name Device type ViP address IP address 1456B 5 Device List Information 1456B module 00123459 192 168 1 65 Addressing IP address 172 25 160 1 8 264 00000028 192 168 1 54 address 11111112 Switchboard 00001003 192 168 1 64 Description Master Slave UTCE Smart H264 00000006 192 168 1 56 8 316 H264 00000103 License activation wizard License activation Select license file s License code Slave Master Telephone 10 11 10 Add license file s lt BACK Y Filter Window Messages 15 Navigation Tree lt Comelit 8280 71 6304 puin TS TERE crzo 6202W 6231 5 SIS Slate 98 1 PEEL 6501 0 E 6304 6202W c
26. pedia libera http it wikipedia org wiki Indirizzo IP Public IP address 2015 June 8 Wikipedia L enciclopedia libera http it wikipedia org wiki Indirizzo IP pubblico Power over Ethernet 2015 June 8 Wikipedia L enciclopedia libera http it wikipedia org wiki Power over Ethernet Port forwarding 2015 June 8 Wikipedia L enciclopedia libera http it wikipedia org wiki Port forwarding The contents of this page sourced from Wikipedia are distributed through licenza Creative Commons Attribuzione Condividi allo stesso modo 3 0 The brands and commercial names appearing in this publication remain the property of their respective owners BACK 23 1st edition 07 2015 code 2040001422 8 023903 www comelitgroup com amp Cornellit Passion Technology Design
27. r are valid for more than one SIP phone line re enter the username password and user ID in the subsequent rows for all the phone lines purchased For example if 5 SIP phone lines have been purchased for which you have 1 username 1 password and 1 user ID enter the same credentials in each of the first 5 rows d The phone lines are shared between all the users of the system connected to the device 1456B and are managed on a first come first served basis BACK amp Cornelit 8 Apartments configuration In the apartments configuration screen each apartment can be assigned a license a ViP address unequivocal and a description to allow easy identification of the apartment and the user An apartment can be enabled for each available license 1 Select device 1456B and select Main Settings DynDNS a 2 Configure the individual apartments max 200 b e Enabling enable disable the license for the apartment by selecting Enabled Disabled e License type assign the type of license purchased for the apartment choosing between Slave Master Telephone address enter an unequivocal address to identify the apartment e Description enter a description to identify the apartment 3 Press Write page c to save the current settings amp Manager Local Online File Home Device List xe Wl Output Window Ba ftourunao 3207 amp amp AP Kk 58 Synopt
28. r example if you wish to set a different port for connection of the app or if there is a static public address you wish to use for remote connection e change the maximum number of video connections on the network max 16 or on the App max 4 1 Select the device 1456B and select Main Settings App connection settings a 2 Edit the values you wish to personalise App connection settings Local address leave the field empty if you wish to set as the local address the address of interface A as specified in the page Addressing IP address e Local remote TCP UDP port default 64100 for some internet service providers port 64100 is not available if the Remote App fails to register try changing the address of the port with one of the following 25 80 110 143 open the respective ports on the router see page 11 and edit the values on the ComelitViP Remote App Remote address leave the field empty if you wish to set as the remote address the hostname registered during configuration of the DynDNS settings If necessary you can assign a static public address for remote connection Video connections Maximum video connections on net maximum number of simultaneous video connections on the network max 16 Maximum video connections on tunnel App maximum number of simultaneous video connections on the App max 4 3 Press Write page b to save the current settings ViP Manager Local Online
29. r powering equipment the same cable as that used for Ethernet connection It is very useful when there is no convenient electrical power source near the termination or when you wish to reduce the number of elements and wires for example an IP phone on a desk can be powered directly via the Ethernet cable in Power over Ethernet thereby eliminating the need for a power supplier and its cable making for a simpler less cluttered installation For the moment these techniques are used mainly to power devices that consume only a little power such as VoIP telephones access points and webcams Port forwarding in computer networks port forwarding is the operation that allows the transfer of data from one device to another via a specific communication port This technique can be used to allow an external user to reach a host with a private IP address within a LAN via a port of the corresponding public IP address This operation requires a router capable of automatic translation of network addresses or NAT Sources Dynamic DNS 2015 June 8 Wikipedia L enciclopedia libera http it wikipedia org wiki Dynamic DNS Dynamic Host Configuration Protocol 2015 June 8 Wikipedia L enciclopedia libera http it wikipedia org wiki Dynamic Host Configuration Protocol Gateway information technology 2015 June 8 Wikipedia L enciclopedia libera http it wikipedia org wiki Gateway informatica IP Address 2015 June 8 Wikipedia L enciclo
30. restore functions are only available from the configuration web pages to access the web pages see page 18 1 As described on page 18 connect to the web pages of the device in local or remote and log in 2 Access the Backup Restore section by pressing Backup Restore a 3 Press Make Backup b to create a backup of the current configuration 4a Press Restore c and confirm 5a Press Reboot d to activate the saved configuration 4b Press Delete e to cancel backup of the configuration amp cCornelit Comelit 1456B Backup Restore amp cCornelit Apartments Password Change Available Configuration Backups Configuration Backup files max 5 will be saved on the device itself Diagnostics BACKUP FILE DELETE RESTORE ides 000001 tar gz e C b Licenses Installer Logout SIP Parameters amp 2015 by Comelit S p A All rights reserved Version 1 3 rc3 Uptime 0 days 04 39 05 Used mem 26 90 MB English Reboot with predetermined network settings The function reboot with predetermined network settings allows you restart the device with the default network parameter settings interface A 192 168 1 200 while keeping the other settings unchanged v With the dip switches the default positions OFF 1 Switch off the power supply the device Set DIP 1 to ON 2 3 Power on the device 4 Wait 20 40 seconds until the LEDs start flashing slowly and alternately 1
31. rk Interface 1 port IP address mode Autoip Assign to device 1456 network settings that are compatible with those of the devices connected to interface IP address 169 254 129 108 IP netmask 255 255 0 0 Use default gateway False A so that they can communicate Interface Remapping Enable Use default gateway ONLY for the interface connected to Physical ViP interface the router interface A by default DNS servers Primary DNS Secondary DNS Page Help device 1456B will now be in the same network as the router 192 168 0 X A al ONLY WITH COMELIT RED CABLE 2 7 000500 ONLY WITH COMELIT RED CABLE 2E7T000500 FIXED POE POE NON POE INTERFACE A STATIC IP ADDRESS 192 168 0 5 192 168 0 ROUTER 192 168 0 1 Installer PC In the cases of ViP Network Internet connection network systems take particular care with regard to the network interface settings and do not configure interfaces A and B with the same addresses or similar parameters each IP address must be unequivocal the addresses of the interfaces A and B must not belong to the same subnet A lt BACK 6 PERFORM A DHCP SYSTEM SCAN AND ASSIGN ADDRESS Follow the procedure below to perform a system scan in DHCP to locate all the devices connected to interfaces A and B e an IP address will be automatically assigned to
32. t to connect devices that require a power supply door entry monitors for example A2 non POE settable Ethernet port POE default Static IP address 192 168 1 200 netmask 255 255 255 0 Set the port as POE if you want to connect devices that require a power supply door entry monitors for example A1 Ethernet port POE default Static IP address 192 168 1 200 netmask 255 255 255 0 cvi cv2 connect to the router e or PC using the red Comelit cable 2 7 000500 DO NOT USE STANDARD DO NOT USE STANDARD Sh lt CV1 CV2 NON POE STANDARD ETHERNET CV3 CV4 NON POE STANDARD ETHERNET amp Cornelit Configuration of Art 1456B This operation requires a PC loaded with the software Manager version 2 3 0 or later downloadable from the website www comelitgroup com An active internet connection is also required 1 Connection gt Article1456B has 2 network interfaces A and B labelled for easy identification which can be configured separately to meet different system requirements Depending on the type of system connect the devices as shown in the following figures ViP SYSTEM 1441 Art 1441B INTERFACE B B 40 56 Art 1456B IP ADDRESS AUTOIP AGES F 8 ONLY WITH RED CABLE 2E7T000500 E A T
33. t service provider v With the PC still connected by Ethernet cable to article 14568 see page 3 1 Access the browser and enter the IP address of the router in the navigation bar for example 192 168 1 1 eoo S nip 192 198 1 1 2 Log in by entering the username and password these can be found in the router user manual A The port configuration method may differ according to the brand and type of router used 3 Look for the sections Port Opening or Apps and games or Port Forwarding if not displayed on the main menu search for them in Advanced settings and add the ports you wish to configure 4 Fill in the configuration panel see example in the figure below Enter a name Select the desired protocol for example TCP for the port 8080 TCP UDP for the port 64100 For the external port enter the desired value e g 8080 64100 enter the same value in the Starting and Ending fields to open a single port For the internal port enter the desired value 8080 64100 enter the same value in Starting and Ending fields to open a single port Enter the IP address of the ViP gateway for example default 192 168 1 200 Confirm 0 0 5 Repeat the procedure for each port you wish to open Ports Custom Services service Name Intercall remote ViP Service Type TCPJUDP External Starting Port
34. the devices in addressing mode Autoip connected to interface an address will be automatically assigned to the devices in addressing mode DHCP connected to interface A if the system is connected to a server with the DHCP function active e devices with a static address will be identified only if they have a network address that is compatible with that of interface A CASE 2 1 From Options a Local connections b tick DHCP Enable c and confirm d Device List a aa Ge a 1 Output Window 4 E a e b Clase ors x 1 aN P Hier Window a Options g 55 Synoptic AE HI gt 5 Local ScanSystem Selective Read Barcode e M E TE Device Groups 8 Navigation Tree Name Device type ViP address IP address Device List Options General Local Connections Connessione 1456B Name Impianto UTCE Impianto UTCE wv Network interface Intel R PRO Wireless 2200BG Netw Refresh AN IP COMPATIBLE DHCP enable 213 WITH THE SYSTEM WILL BE ASSIGNED TO THE PC 192 168 0 30 SYSTEM SCAN IN DHCP Installer PC 2 Launch the system scan by pressing Scan System e all the devices connected to the system will be displayed in the device list 3 Select the device 1456 B f select Addressing ViP address g assign an unequivocal ViP address to the device h and press Write page i to save the current settings
Download Pdf Manuals
Related Search
Related Contents
0.2VC OpenEyes Technicians and Nurses AC401 international Portugues/Produtos/NXL/00 Doc Serie/Manuais e Apostilas Atelier « boule de graisse » Samsung Galaxy 3 Käyttöopas(Eclair) Français français - Hachette Livre International documents/media17964_OJbtTqZxkyoDnjP Electrolux 2573-4 KA Refrigerator User Manual Port-A-Cool PACJS1600 Use and Care Manual PR 1 old nélkül léc Copyright © All rights reserved.
Failed to retrieve file