Home

Spec Sheet

image

Contents

1. Dimensions 0 5 20 Hp NEMA Type 1 Style 1 AA1 0 5 20 Hp NEMA Type 1 Style 2 AA2 Maximum Area Factor AO Maximum Area Factor A130 Approximate Weight 43 kg 95 Ibs Approximate Weight 57 kg 125 Ibs millimeters inches millimeters inches 305 8 305 8 E 12 04 S map 220 1 269 8 BA 269 8 8 69 10 62 10 62 E Td A M ELLE AO 667 8 667 8 26 29 A 26 29 i AS O o A 1 TT IM TIED i N IM UEM Y m Y amp U 0 5 20 Hp NEMA Type 1 Style 3 AA3 0 5 20 Hp NEMAType 3 4 outdoor or 4 12 AF Maximum Area Factor A270 indoor Styles 1 through 10 Approximate Weight 70 kg 155 Ibs millimeters inches lt W gt lt D g H j I un Y o EN QUID i MO Y 5 Al 7 H Ww D Style mm in mm in mm in 1 457 2 18 304 8 12 304 8 12 2 457 2 18 406 4 16 304 8 12 3 558 8 22 406 4 16 304 8 12 4 812 8 32 330 2 13 304 8 12 5 812 8 32 609 6 24 406 4 16 6 965 2 38 609 6 24 406 4 16 7 1270 0 150 609 6 24 406 4 16 8 11176 44 914 4 36 406 4 16 9 1270 0 150 914 4 36 406 4
2. Description Must be Used with Cannot be Used with Enclosure A or H HIM 3 A G Brake IGBT Y or Base Drive N Emission A or B Comm Option C D E H Vector Control drives cannot be used with Comm L P R S or N I O Option A B C or D Feedback Options H L or G1 0 or 1 ND or HD Option HIM Options 3 A G Only one HIM option can be selected 3 A G Comm Options Sny on drive mounted comm option can be 1 0 Options Only one I O option can be selected Feedback Options Vector 24V dc or Vector 115V ac Only one feedback option can be selected BO B1 B1 C1 or C5 BO P2 P3 P6 P12 B2 B1 amp J2 C1 C5 C5 C1 E9 G1 HIM codes 3 A G Vector Control I O C or D HD Any base drive unless ND is selected ND J1 J2 Only 2 drive digital outputs J3 Only 2 drive digital outputs J4 Only 2 drive digital outputs J5 Only 2 drive digital outputs J6 Only 2 drive digital outputs J7 Only 2 drive digital outputs J8 J4 L1 L2 M3 J4 N1 N2 N3 N5 ND Any base drive unless HD is selected HD P1 P2 P3 P4 P6 P7 P2 P1 P3 P4 P6 P7 B1 P3 P1 P2 P4 P6 P7 B1 P4 P1 P2 P3 P6 P7 P6 P1 P2 P3 P4 P7 B1 P7 P1 P2 P3 P4 P6 P11 C1 or C5 P12 J2 C1 or C5 B1 B2 S1 S9 Only 2 drive digital outputs
3. kW Hp Amps Cat No Cat No 3 Impedance 2 2 3 0 12 1321 3R12 A 1321 3RA12 A 3 7 5 0 17 5 1321 3R18 A 1321 3RA18 A 5 5 1 5 24 1321 3R25 A 1321 3RA25 A 7 5 10 33 1321 3R35 A 1321 3RA35 A 11 15 49 1321 3R45 A 1321 3RA45 A 15 20 65 1321 3R55 A 1321 3RA55 A 18 5 25 75 1321 3R80 A 1321 3RA80 A 22 30 90 1321 3R80 A 1321 3RA80 A 30 40 120 1321 3R100 A 1321 3RA100 A 37 50 145 1321 3R130 A 1321 3RA130 A 5 Impedance 2 2 3 0 12 1321 3R12 B 1321 3RA12 B 3 7 5 0 17 5 1321 3R18 B 1321 3RA18 B 5 5 7 5 24 1321 3R25 B 1321 3RA25 B 75 10 33 1321 3R35 B 1321 3RA35 B 11 15 49 1321 3R45 B 1321 3RA45 B 15 20 65 1321 3R55 B 1321 3RA55 B 18 5 25 75 1321 3R80 B 1321 3RA80 B 22 30 90 1321 3R80 B 1321 3RA80 B 30 40 120 1321 3R100 B 1321 3RA100 B 37 50 145 1321 3R130 B 1321 3RA130 B 240V 60 Hz Three Phase PowerFlex 400 Ratings IPOO Open Style IP11 NEMA Type 1 kW Hp Amps Cat No Cat No 3 Impedance 2 2 3 0 12 1321 3R12 A 1321 3RA12 A 3 7 5 0 17 5 1321 3R18 A 1321 3RA18 A 5 5 7 5 24 1321 3R25 A 1321 3RA25 A 7 5 10 33 1321 3R35 A 1321 3RA35 A 11 15 49 1321 3R45 A 1321 3RA45 A 15 20 65 1321 3R55 A 1321 3RA55 A 18 5 25 75 1321 3R80 A 1321 3RA80 A 22 30 90 1321 3R80 A 1321 3RA80 A 30 40 120 1321 3R100 A 1321 3RA100 A 37 50 145 1321 3R130 A 1321 3RA130 A 5 Impedance 2 2 3 0 12 1321 3R12 B 1321 3RA12 B 3 7 5 0 17 5 1321 3R18 B 1321 3RA1
4. IP66 NEMA Type Output Amps Nominal Power Ratings 4X 12 with HIM 480V ac Inputx 380 400V ac Input Normal Duty Heavy Duty Cat No Frame Cont 1 Min 3 Sec Cont 1 Min 3 Sec kw Hp kW Hp 20A Size 14 12 1 6 1 3 1 4 1 9 0 37 0 5 0 25 0 33 D1P1C3AYNNNCO B 2 1 2 4 3 2 2 1 2 4 32 0 75 1 0 0 55 0 75 D2P1C3AYNNNCO B 3 4 4 5 6 0 3 5 4 5 6 0 1 5 2 0 1 1 1 5 D3P4C3AYNNNCO B 5 0 5 5 7 5 5 0 5 5 7 5 22 3 0 1 5 2 0 D5POC3AYNNNCO B 8 0 8 8 12 8 7 9 9 13 2 4 0 5 0 3 0 3 0 D8POC3AYNNNCO B 11 12 1 16 5 11 5 13 17 4 5 5 7 5 4 0 5 0 DO11C3AYNANCO D 14 16 5 22 15 4 17 2 23 1 7 5 10 5 5 7 5 D014C3AYNANCO D 22 24 2 33 22 24 2 33 11 15 7 5 10 DO22C3AYNANCO D 27 33 44 30 33 45 15 20 n 15 D027C3AYNANCO D 34 40 5 54 37 45 60 18 5 25 15 20 DO34C3AYNANCO D 40 81 68 43 56 74 22 30 18 5 25 DO40C3AYNANCO D 52 60 80 60 66 90 30 40 22 30 D052C3AYNANCO E 65 78 104 72 90 120 37 50 30 40 D065C3AYNANCO E Catalog code corresponds to output amps in these columns Drive must be programmed to lower voltage to obtain higher currents shown at right 500 600V ac Three Phase Drives IP66 NEMA Type Output Amps Nominal Power Ratings 4X 12 with HIM 600V ac Input Normal Duty Heavy Duty Cat No Cont 1 Min 3 Sec kW Hp kw Hp 20A Frame Size 0 9 1 0 1 4 0 37 0 5 0 25 0 33 EOP9C3AYNNNCO B 17 1 9 2 6 0 75 1 0 0 55 0 75 E1P7CSAYNNNCO B 2T 3 6 4 8 15 2 0 1 1 1 0 E2P7C3AYNNNCO B 3 9 4 3 5
5. Position 1 3 4 5 7 8 9 10 11 12 13 14 15 16 17 20D D 2P1 A 0 E Y N A N A N E a b e d e f g h i j k l m a c2 c3 Drive ND Rating ND Rating Code Type 400V 50 Hz Input 480V 60 Hz Input 20D PowerFlex 700S Code Amps kW Code Amps Hp 2P1 2 1 0 75 2P1 2 1 1 0 3P5 3 5 1 5 3P4 3 4 2 0 b 5P0 5 0 2 2 SRO 5 3 0 Voltage Rating 8P7 8 7 4 0 8P0 8 5 0 Code Voltage Ph Prechg 011 11 5 5 5 011 11 7 5 BS 240V ac 3 015 15 4 7 5 014 14 10 Cs 400V ac 3 022 22 11 022 22 15 D 480V ac 3 030 30 15 027 27 20 Es 600V ac 3 037 37 18 5 034 34 25 F 3e 690V ac 3 043 43 22 040 40 30 H 3e 540V dc N 056 56 30 052 52 40 J 650V de EN N 072 72 37 065 65 50 K3 810V dc N 085 85 45 077 77 60 105 105 55 096 96 75 M amp 932V dc N 125 125 55 125 125 100 Ze u _ Li 140 140 75 156 156 125 um 650V de Y 170 170 90 180 180 150 Note CE Certification testing has not been 260 260 182 248 248 200 performed on 600V class drives Frames 5 amp 6 Only 261 261 132 261 261 200 3 Frames 5 amp up 300 300 160 300 300 250 8 For DC input on Frames 1 4 use the 385 385 200 385 385 300 corresponding AC input code B C D or E 460 460 250 460 460 350 500 500 250 500 500 450 c1 590 590 315 590 590 500 ND Rating 650 650 355 650 650 500 730 730 400 730 730 600 208 240V BORZ Input 820 4 820 450 820 4 820 700 Code rate aud Hp 920 920 500 920 920 800 Amps Amps 4P2 4 8 4 2 1 0 1K0 a
6. Drive Cat No Duty Hp Cat No Cat No Cat No Cat No 20AEOP9 Heavy Duty 0 33 1321 3R1 C 1321 3RA1 C 1321 3R1 B 1321 3RA1 B 20AEOP9 Normal Duty 0 5 1321 3R1 C 1321 3RA1 C 1321 3R1 B 1321 3RA1 B 20AE1P7 Heavy Duty 0 75 1321 3R2 B 1321 3RA2 B 1321 3R2 B 1321 3RA2 B 20AE1P7 Normal Duty 1 0 1321 3R2 B 1321 3RA2 B 1321 3R2 B 1321 3RA2 B 20AE2P7 Heavy Duty 1 5 1321 3R2 A 1321 3RA2 A 1321 3R4 D 1321 3RA4 D 20AE2P7 Normal Duty 2 0 1321 3R4 C 1321 3RA4 C 1321 3R4 D 1321 3RA4 D 20AE3P9 Heavy Duty 2 0 1321 3R4 C 1321 3RA4 C 1321 3R4 C 1321 3RA4 C 20AE3P9 Normal Duty 3 0 1321 3R4 C 1321 3RA4 C 1321 3R4 C 1321 3RA4 C 20AE6P1 Heavy Duty 3 0 1321 3R4 C 1321 3RA4 C 1321 3R8 C 1321 3RA8 C 20AE6P1 Normal Duty 5 0 1321 3R8 C 1321 3RA8 C 1321 3R8 C 1321 3RA8 C 20AE9PO Heavy Duty 5 0 1321 3R8 C 1321 3RA8 C 1321 3R12 C 1321 3RA12 C 20AE9PO Normal Duty 7 5 1321 3R12 C 1321 3RA12 C 1321 3R12 C 1321 3RA12 C 20AE011 Heavy Duty 7 5 1321 3R12 C 1321 3RA12 C 1321 3R12 B 1321 3RA12 B 20AE011 Normal Duty 10 1321 3R12 B 1321 3RA12 B 1321 3R12 B 1321 3RA12 B 20AE017 Heavy Duty 10 1321 3R12 B 1321 3RA12 B 1321 3R18 C 1321 3RA18 C 20AE017 Normal Duty 15 1321 3R18 B 1321 3RA18 B 1321 3R18 C 1321 3RA18 C 20AE022 Heavy Duty 15 1321 3R18 B 1321 3RA18 B 1321 3R25 B 1321 3RA25 B 20AE022 Normal Duty 20 1321 3R25 B 1321 3RA25 B 1321 3R25 B 1321 3RA25 B 20AE027 Heavy Duty 20 1321 3R25 B 1321 3RA25 B 1321 3R35 C 1321 3RA
7. From To Multiply by Length Inches in Millimeters mm 25 4 Inches in Centimeters cm 2 54 Feet ft Meters m 0 305 Yards yd Meters m 0 914 Millimeters mm Inches in 0 0394 Centimeters cm Inches in 0 394 Meters m Feet ft 3 28 Meters m Yards yd 1 09 Area Square inches in Square millimeters mm 645 Square inches in Square centimeters cm 16 45 Square feet ft Square meters m 0 0929 Square yards yd Square meters m 0 836 Square millimeters mm Square inches in 0 00155 Square centimeters cm Square inches in 0 155 Square meters m Square feet ft 10 8 Square meters m Square yards yd 1 20 Weight Ounces oz Grams g 28 3 Pounds Ib Kilograms kg 0 454 Grams g Ounces oz 0 0353 Kilograms kg Pounds Ib 2 20 Volume Cubic inches in Cubic centimeters cm 16 4 Cubic feet ft Cubic meters m 0 0283 Cubic inches in Liters L 0 0164 Cubic feet ft Liters L 28 3 Gallons Imp Liters L 4 55 Gallons US Liters L 3 79 Cubic centimeters cm Cubic inches in 0 061 Cubic meters m Cubic feet ft 35 3 Liters L Cubic inches in 61 0 Liters L Cubic feet ft 0 0353 Liters L Gallons Imp 0 220 Liters L Gallons US 0 264 Pressure Pounds square inch psi Kilopascals kPa 6 89 Pounds square inch psi Bars Bar 0 0689 Kilopascals kPa Pounds square inch psi 0 145 Bars Bar
8. ene Duty Hp Cat No Cat No Cat No Cat No 20DD1P1 Heavy Duty 0 33 1321 3R1 B 1321 3RA1 B 1321 3R2 C 1321 3RA2 C 20DD1P1 Normal Duty 0 5 1321 3R1 B 1321 3RA1 B 1321 3R2 C 1321 3RA2 C 20DD2P1 Heavy Duty 0 75 1321 3R2 C 1321 3RA2 C 1321 3R2 B 1321 3RA2 B 20DD2P1 Normal Duty 1 1321 3R2 B 1321 3RA2 B 1321 3R2 B 1321 3RA2 B 20DD3P4 Heavy Duty 1 5 1321 3R4 D 1321 3RA4 D 1321 3R4 D 1321 3RA4 D 20DD3P4 Normal Duty 2 1321 3R4 D 1321 3RA4 D 1321 3R4 D 1321 3RA4 D 20DD5P0 Heavy Duty 2 1321 3R4 D 1321 3RA4 D 1321 3R8 D 1321 3RA8 D 20DD5P0 Normal Duty 3 1321 3R8 D 1321 3RA8 D 1321 3R8 D 1321 3RA8 D 20DD8P0 Heavy Duty 3 1321 3R8 D 1321 3RA8 D 1321 3R8 C 1321 3RA8 C 20DD8P0 Normal Duty 5 1321 3R8 C 1321 3RA8 C 1321 3R8 C 1321 3RA8 C 20DD011 Heavy Duty 5 1321 3R8 C 1321 3RA8 C 1321 3R12 C 1321 3RA12 C 20DD011 Normal Duty TS 1321 3R12 C 1321 3RA12 C 1321 3R12 C 1321 3RA12 C 20DD014 Heavy Duty 7 5 1321 3R12 C 1321 3RA12 C 1321 3R18 C 1321 3RA18 C 20DD014 Normal Duty 10 1321 3R18 C 1321 3RA18 C 1321 3R18 C 1321 3RA18 C 20DD022 Heavy Duty 10 1321 3R18 C 1321 3RA18 C 1321 3R25 C 1321 3RA25 C 20DD022 Normal Duty 15 1321 3R25 C 1321 3RA25 C 1321 3R25 C 1321 3RA25 C 20DD027 Heavy Duty 15 1321 3R25 C 1321 3RA25 C 1321 3R25 C 1321 3RA25 C 20DD027 Normal Duty 20 1321 3R35 Ct 1321 3RA35 C 1321 3R25 C 1321 3RA25 C 20DD034 Heavy Duty 20 1321 3R35 Ct 1321 3RA35 Ct 1321 3R35 C 1321 3RA35 C
9. Drive Ratings IP20 NEMA Type Open IP20 Flange Mount Output Current kw Hp A Cat No Frame Size Cat No 0 4 0 5 2 3 22B V2P3N104 B 22B V2P3F104 0 75 1 0 5 0 22B V5PON104 B 22B V5POF104 1 1 5 6 0 22B V6PON104 B 22B V6POF104 Meets IP40 54 65 NEMA 1 12 4 4X when installed in an enclosure of like rating 240V ac Single Phase Drives 50 60 Hz Drive Ratings IP20 NEMA Type Open IP20 Flange Mount Output Current kw Hp A Cat No Frame Size Cat No With Integral S Type EMC Filter 0 4 0 5 2 3 22B A2P3N114 B 0 75 1 0 5 0 22B A5PON114 B 1 5 2 0 8 0 22B A8PON114 B 2 2 3 0 12 22B A012N114 C No Filter 0 4 0 5 2 3 22B A2P3N104 B 22B A2P3F104 0 75 1 0 5 0 22B A5PON104 B 22B A5POF104 1 5 2 0 8 0 22B A8PON104 B 22B A8POF104 22 3 0 12 22B A012N104 C 22B A012F104 Meets IP40 54 65 NEMA 1 12 4 4X when installed in an enclosure of like rating This filter is suitable for use with a cable length of up to 10 meters for Class A and 1 meter for Class B environments 240V ac Three Phase Drives 50 60 Hz No Filter Drive Ratings IP20 NEMA Type Open IP20 Flange Mount Output Current kw Hp A Cat No Frame Size Cat No 0 4 0 5 2 3 22B B2P3N104 B 22B B2P3F104 0 75 1 0 5 0 22B B5PON104 B 22B B5POF104 1 5 2 0 8 0 22B B8PON104 B 22B B8P0F104 22 3 0 12 22B B012N104 B 22B B012F104 3 7 5 0 17 5 22B B017N104 B 22B B017F104 5 5 7 5 24 22B B024N104 C 22B B0
10. h Brake Resistor e Code w Resistor I HIM Y Yes N No Feedback Code Operator Interface Not available for Frame 3 drives or larger Code Type 0 Blank Cover m 2 Digital LCD 2 None a 1 Encoder 12V 3 Full Numeric LCD P 4 Analog LCD 5 Prog Only LCD Emission Door Mount IP66 NEMA Type 12 Full Code CE Filter CM Choke n J gt Numeric LCD HIM A Yes Yes E Y Door Mount IP66 NEMA Type 12 Prog B Yes No uture Use K gt Only LCD HIM Note CE Certification testing has not been gt Only available with Stand Alone IP54 drives performed on 600V class drives below 77 Amps n Custom Firmware f j Code Type Documentation M AD gt 60 Hz Maximum Comm Slot Code Type gt Must be used with Vector Control option C or A User Manual Code Version D Position k Postions m n are only required C ControlNet Coax when custom firmware is supplied N No Manual A D DeviceNet E EtherNet IP R RIO S RS 485 N None amp amp 5 Allen Bradley E AC Adjustable Frequency Drives PowerFlex 700 Standard Drives Selection Wall Mount IP21 NEMA Type 1 Position d A 208 240V ac Three Phase Drives 240V ac Input 208V ac Input IP20 NEMA Type 1 Output Amps Normal Heavy Output Amps Normal Heavy Frame Cont 1 Min 3 Sec Duty Hp Duty Hp Cont 1 Min 3 Sec Duty kW Duty kW Cat N
11. Contents Description Standard Product Conformity to Standards this page Drive Description this page Catalog Number Explanation Phase II page 124 Product Selection Phase II page 126 Catalog Number Explanation Phase page 131 Product Selection Phase page 133 User Installed Options page 134 Isolation Transformers page 136 Input amp Output Line Reactors page 137 Drive Application Software page 143 Factory Installed Options page 144 Conformity to Standards The PowerFlex 700S conforms to the following Conformity to Standard Product UL Listed Y c UL Listed Y CE Approved Y C Tick Y IEC Designed to Meet Y Drive Description The PowerFlex 700S AC drive offers optimized integration for the most demanding drive control and drive system applications The PowerFlex 700S with DriveLogix combines the powerful performance and flexible control of a PowerFlex AC drive with the high performance Logix engine to produce a highly functional cost effective drive and control solution Available ratings include e 1 to 100 Hp at 240V ac e 1 to 900 Hp at 480V ac 1 to 900 Hp at 600V ac 50 to 800 kW at 690V ac Allen Bradley Expanded Slim An LCD Human Interface Module also used with the PowerFlex 70 700 and 700H provides local startup metering programming and troubleshooting To meet a wide variety of application needs the PowerFlex 700S AC drive is configurable
12. Description Cat No SynchLink Board for Phase II Control 3 20D P2 SLBO SynchLink Base Block up to 4 splitter blocks 1751SLBAVA SynchLink 4 Port Splitter Block 1751SL4SP A SynchLink Bypass Switch Block 1751SLBP A 2x1 Meter Fiber Link for Power Monitor SynchLink 1403CF001 2x3 Meter Fiber Link for Power Monitor SynchLink 1403CF003 2x5 Meter Fiber Link for Power Monitor SynchLink 1403CF005 10 Meter Fiber Link for Power Monitor SynchLink 1403CF010 20 Meter Fiber Link for Power Monitor SynchLink 1403CF020 50 Meter Fiber Link for Power Monitor SynchLink 1403CF050 100 Meter Fiber Link for Power Monitor SynchLink 1403CF100 250 Meter Fiber Link for Power Monitor SynchLink 1403CF250 36 For use with Phase Il Control ONLY Feedback Option Kits Description Cat No 2nd Encoder 5V 12V gt 20D P2 ENCO Resolver 20D RES A1 Stegmann High Resolution Hyperface Encoder 20D STEG B1 Multi Device Interface 20D MDI C1 Drive Guard Safe Off w 2nd Encoder 20D P2 DG01 Requires Expanded Cassette when used with Phase II Control 3 For use with Phase Il Control ONLY Auxiliary Control Power Supply Description Cat No Auxiliary Control Power Supply 20 24V AUX1 DriveLogix Option Kits Description Cat No Logix Expansion board for DriveLogix5730 20D DL2 LEBO Industrial CompactFlash 64 Mb for DriveLogix5730 1784 CF64 DriveLogix5720 Controller 256k bytes of User Available 20D DL AO Memory DriveLogix5720 Memory Expansion 512k
13. Drive Input Brake Resistance Voltage Q Frame Cat No 62 1 0 5 5 0 Hp 20BB DB1 1 208 240V ac 22 1 7 5 Hp 20BB DB2 1 22 2 20BB DB1 2 115 1 20BD DB1 1 380 480V ac 68 2 20BD DB1 2 460V 60 Hz Three Phase 460V Primary 8 460V Secondary 575V 60 Hz Three Phase 575V Primary 8 575V Secondary IP32 NEMA Type 3R IP32 NEMA Type 3R IP32 NEMA Type 3R Cat No Cat No Cat No 0 25 0 33 1321 3TW005 AA 1321 3TW005 BB 0 37 0 5 1321 3TW005 AA 1321 3TW005 BB 0 55 0 75 1321 3TW005 AA 1321 3TW005 BB 0 75 1 0 1321 3TW005 AA 1321 3TW005 BB 1321 3TW005 CC 1 1 1 5 1321 3TW005 AA 1321 3TW005 BB 1 5 2 0 1321 3TW005 AA 1321 3TW005 BB 1321 3TW005 CC 2 2 3 0 1321 3TW005 AA 1321 3TW005 BB 1321 3TW005 CC 4 0 5 0 1321 3TW007 AA 1321 3TW007 BB 1321 3TW007 CC 5 5 7 5 1321 3TW011 AA 1321 3TW011 BB 1321 3TW011 CC 7 5 10 1321 3TW014 AA 1321 3TW014 BB 1321 3TW014 CC 11 15 1321 3TW020 AA 1321 3TW020 BB 1321 3TW020 CC 15 20 1321 3TW027 AA 1321 3TW027 BB 1321 3TW027 CC 18 5 25 1321 3TW034 AA 1321 3TW034 BB 1321 3TW034 CC 22 30 1321 3TW040 AA 1321 3TW040 BB 1321 3TW040 CC 30 40 1321 3TW051 AA 1321 3TW051 BB 1321 3TW051 CC 37 50 1321 3TH063 AA 1321 3TH063 BB 1321 3TH063 CC 45 60 1321 3TH075 AA 1321 3TH075 BB 1321 3TH075 CC 55 75 1321 3TH093 AA 1321 3TH093 BB 1321 3TH093 CC 75 100 1321 3TH118 BB 1321 3TH118 C
14. Catalog number corresponds to output amps in these columns Drive must be programmed to lower voltage to obtain higher currents shown at right Frame 5 and 6 drives have dual current ratings one for normal duty applications and one for heavy duty applications in parenthesis The drive may be operated at either rating gt Rating is limited to 45 C surrounding air Rating is limited to 40 C surrounding air 810V dc Input Drives 810V dc Input 690V dc Input IP20 NEMA Type 1 Output Amps Normal Heavy Output Amps Normal Heavy DC Pre Cat No Frame Cont 1 Min 3 Sec Duty Hp Duty Hp Cont 1 Min 3 Sec Duty kW Duty kW charge 200 Size 99 77 109 116 126 138 100 75 98 82 108 123 127 140 90 75 Y TO99AOENNANANE 5 144 125 158 188 216 250 150 125 142 119 156 179 213 238 132 110 Y T144A0ENNANANE 6 Catalog number corresponds to output amps in these columns Drive must be programmed to lower voltage to obtain higher currents shown at right Frame 5 and 6 drives have dual current ratings one for normal duty applications and one for heavy duty applications in parenthesis The drive may be operated at either rating Rating is limited to 40 C surrounding air Allen Bradley 129 AC Adjustable Frequency Drives PowerFlex 700S Flange Mount Front IP20 NEMA Type Open Back Heatsink IP54 NEMA Type
15. 111 AC Adjustable Frequency Drives PowerFlex Drive Packages for Fan amp Pump Applications Input and Output Line Reactors Standalone 208V 60 Hz Three Phase Drive Ratings Input Line Reactor Output Line Reactor IPOO Open Style IP11 NEMA Type 1 IPOO Open Style IP11 NEMA Type 1 kw Hp Amps Cat No Cat No Cat No Cat No 3 Impedance 0 75 1 0 4 8 1321 3R8 B 1321 3RA8 B 1321 3R8 B 1321 3RA8 B 1 5 2 0 7 8 1321 3R8 A 1321 3RA8 A 1321 3R8 A 1321 3RA8 A 2 2 3 0 11 1321 3R12 A 1321 3RA12 A 1321 3R12 A 1321 3RA12 A 4 0 5 0 17 5 1321 3R18 A 1321 3RA18 A 1321 3R18 A 1321 3RA18 A 5 5 7 5 25 3 1321 3R25 A 1321 3RA25 A 1321 3R25 A 1321 3RA25 A 7 5 10 32 2 1321 3R35 A 1321 3RA35 A 1321 3R35 A 1321 3RA35 A 11 15 43 1321 3R45 A 1321 3RA45 A 1321 3R45 A 1321 3RA45 A 5 Impedance 0 75 1 0 4 8 1321 3R8 C 1321 3RA8 C 1321 3R8 B 1321 3RA8 B 1 5 2 0 7 8 1321 3R8 B 1321 3RA8 B 1321 3R8 B 1321 3RA8 B 2 2 3 0 11 1321 3R12 B 1321 3RA12 B 1321 3R12 B 1321 3RA12 B 4 0 5 0 17 5 1321 3R18 B 1321 3RA18 B 1321 3R18 B 1321 3RA18 B 5 5 7 5 25 3 1321 3R25 B 1321 3RA25 B 1321 3R25 B 1321 3RA25 B 7 5 10 32 2 1321 3R35 B 1321 3RA35 B 1321 3R35 B 1321 3RA35 B 11 15 43 1321 3R45 B 1321 3RA45 B 1321 3R45 B 1321 3RA45 B Input line reactors were sized based on the NEC fundamental motor amps Output line reactors were sized based on the VFD rating output currents 11
16. Vector Control option utilizes DPI Only Only Series B Cassettes will ship from the factory after February 1 2005 Feedback Options Vector Control Only Description No Encoder Cat Code Position 0 12V Encoder Encoder option can also be used as a pulse input Special Firmware Description 60 Hz Maximum Position m n 1 Cat Code 3 Must be used with Vector Control option C or D position k in the catalog string Allen Bradley AC Adjustable Frequency Drives PowerFlex 700 Packaged Drives Programs Overview The PowerFlex 700 Packaged Drives Program allows users to create drive packages based on their specific needs This program enhances stand a lone drive functionality through additional control power and packaging options which are ideal for OEM and end users with special installation needs The program has three levels Quick Ship Standard Packaged Drives Engineered Drives Quick Ship Quick Ship products are intended to meet faster than normal delivery requirements Pre defined catalog strings are offered to support shipping one to three business days from date of order entry The current offering is based on NEMA 1 IP20 480V top of frame ratings frame 0 3 These packages are manufactured the same as those used within the Standard Packaged Drives Program noted below and can be ordered through the order entry system Standard Packaged Drives Th
17. 1321 3TW051 BB 1321 3TW051 CC 37 60 1321 3TH063 BB 1321 3TH063 CC EMC Filters Description Frame Cat No External 1 Phase 200 240V 8A Filter A 20A RF 08 A1 External 3 Phase 200 480V 5A Filter A 20A RF 05 A3 These external filters are only for Frame A drives Other Frames are available with internal filters See Factory Installed Options Allen Bradley 61 AC Adjustable Frequency Drives PowerFlex 70 Factory Installed Options Human Interface and Wireless Interface Modules IP20 NEMA Type 1 and Flange Type Drives Position e Cat Code 0 No HIM Blank Cover Cat Code 2 LCD Digital Speed Cat Code 5 LCD Programmer Only Cat Code 3 LCD Full Numeric Cat Code 8 DPI WIM IP66 NEMA Type 4X 12 Drives Position e Cat Code 0 No HIM Blank Cat Code 3 LCD Full Numeric 60 o o ooo ooo ooo 908 Cat Code 5 Cat Code 8 LCD Programmer Only DPI WIM Documentation Cat Code Description Position f English User Manual Multi Language Quick Start A No User Manual N 62 Internal Dynamic Brake Resistors Drive Input Brake Resistance Cat Code Voltage Q Frame Position h A M 62 B Y 200 240V ac C M 22 D M A M 115 B M 380 480V ac C b 62 D Y A y 115 B Y 600V ac C Y D Not Available Internal EMC Filter Drive Input Cat Code Voltage CE Filter Frame Position i Optional B 200 240V ac Standard C
18. 2 2 3 0 6 0 22 RF018 CS 4 0 5 0 10 5 22 RF018 CS 5 5 5 12 22 RF018 CS 7 5 10 17 22 RF018 CS 11 15 22 22 RF026 CS 15 20 30 22 RFDO36 18 5 25 38 22 RFD050 22 30 45 5 22 RFD050 30 40 60 22 RFD070 37 50 72 22 RFD100 45 60 88 22 RFD100 55 75 105 22 RFD150 75 100 142 22 RFD180 90 125 170 Consult Factory 110 150 208 Consult Factory 38 Allen Bradley AC Adjustable Frequency Drives PowerFlex 400 Packaged Drives Programs Overview The Packaged Product program allows users to create Disconnect and Contactor Bypass packages based on their specific needs and requirements A limited factory installed option set is offered to optimize package configurations while providing a versatile and cost effective solution All configurations feature wall mount NEMA Type 1 packaging The program has two levels Standard Packaged Drives The Standard Packaged Drives Program allows users to create drive packages based on their specific needs A complete drive package may be specified by assembling a single catalog number string that includes a base drive and all required options Packaging is available for 208V and 480V systems in NEMA Type 1 enclosures The program consists of a fully defined catalog string identified within this price sheet Three packaged configurations are offered which provide consistent manufacturing and minimize customer resources by reducing engineering manufacturing and installation time Typical delivery is 15 20 business days from
19. 308 308 55 45 Y 20BN192A0ANNANCO 6 260 205 286 305 390 410 100 75 260 205 286 305 390 410 66 55 Y 20BN260A0ANNANCO 6 Catalog number corresponds to output amps in these columns Drive must be programmed to lower voltage to obtain higher currents shown at right Frame 5 and 6 drives have dual current ratings one for normal duty applications and one for heavy duty applications in parenthesis The drive may be operated at either rating 650V dc Input Drives 650V dc Input 540V dc Input IP20 NEMA Type 1 Output Amps Normal Heavy Output Amps Normal Heavy DC Pre Frame Cont 1 Min 3 Sec Duty Hp Duty Hp Cont 1 Min 3 Sec Duty kW Duty kW charge Cat No Size 96 77 106 116 144 154 75 60 105 85 116 128 158 170 55 45 N 20BJ096A0ANNANCO 5 96 77 106 116 144 154 75 60 105 85 116 128 158 170 55 45 Y 20BR096A0ANNANCO 5 125 96 138 144 163 168 100 75 125 96 138 144 163 168 55 45 N 20BJ125A0ANNANCO 5 125 96 138 144 163 168 100 75 125 96 138 144 163 168 55 45 Y 20BR125A0ANNANCO 5 156 125 172 188 233 250 125 100 170 140 187 210 255 280 90 75 N 20BJ156A0ANNANCO 6 156 125 172 188 233 250 125 100 170 140 187 210 255 280 90 75 Y 20BR156A0ANNANCO 6 180 156 198 234 270 312 150 125 205 170 220 255 289 313
20. Frame 5 and 6 drives have dual current ratings one for normal duty applications and one for heavy duty applications in parenthesis The drive may be operated at either rating Rating is limited to 40 C surrounding air Flange Mount Front z IP20 NEMA Type Open Back Heatsink IP54 NEMA Type 12 Position d F 380 480V ac Three Phase Drives 480V ac Input 380 400V ac Input Output Amps Normal Heavy Output Amps Normal Heavy Frame Cont 1 Min 3 Sec Duty Hp Duty Hp Cont 1 Min 3 Sec Duty kW Duty kW Cat No Size 9607 s 106 116 144 154 75 60 105 85 116 128 158 170 55 45 20BDO96FOANNANCO 5 125 96 138 144 163 168 100 75 125 96 138 144 163 168 55 45 20BD125FOANNANCO 5 156 125 172 188 1233 250 125 100 170 140 1187 210 255 280 90 75 20BD156FOANNANCO 6 180 156 198 234 1270 312 150 125 205 170 220 255 289 313 110 90 20BD180FOANNANCO 6 P 80 273 270 372 360 200 150 260 205 286 308 390 410 132 110 20BD248FOANNANCO 6 Catalog number corresponds to output amps in these columns Drive must be programmed to lower voltage to obtain higher currents shown at right Frame 5 and 6 drives have dual current ratings one for normal duty applications and one for heavy duty applications in parenthesis The drive may be operated at either rating Rating is limited to 45 C surrounding air Rating i
21. 0 55 0 75 1321 3TW005 AA 1321 3TW005 BB 0 75 1 0 1321 3TW005 AA 1321 3TW005 BB 1321 3TW005 CC 11 45 1321 3TW005 AA 1321 3TW005 BB 1 5 2 0 1321 3TW005 AA 1321 3TW005 BB 1321 3TW005 CC 2 2 3 0 1321 3TW005 AA 1321 3TW005 BB 1321 3TW005 CC 4 0 5 0 1321 3TW007 AA 1321 3TW007 BB 1321 3TW007 CC 5 5 7 5 1321 3TW011 AA 1321 3TW011 BB 1321 3TW011 CC 7 5 10 1321 3TWO14 AA 1321 3TW014 BB 1321 3TW014 CC 11 15 1321 3TW020 AA 1321 3TW020 BB 1321 3TW020 CC 15 20 1321 3TW027 AA 1321 3TW027 BB 1321 3TW027 CC 18 5 25 1321 3TW034 AA 1321 3TW034 BB 1321 3TW034 CC 22 30 1321 3TW040 AA 1321 3TW040 BB 1321 3TW040 CC 30 40 1321 3TW051 AA 1321 3TW051 BB 1321 3TW051 CC 37 60 1321 3TH063 AA 1321 3TH063 BB 1321 3TH063 CC 45 60 1321 3TH075 AA 1321 3TH075 BB 1321 3TH075 CC 55 75 1321 3TH093 AA 1321 3TH093 BB 1321 3TH093 CC 75 100 1321 3TH118 BB 1321 3TH118 CC 90 125 1321 3TH145 BB 1321 3TH145 CC 110 150 1321 3TH175 BB 1321 3TH175 CC 149 200 1321 3TH220 BB Allen Bradley 83 AC Adjustable Frequency Drives PowerFlex 700 Input and Output Line Reactors 240V 60 Hz Three Phase 3 Impedance Input Line Reactor Output Line Reactor IPOO Open Style IP11 NEMA Type 1 IPOO Open Style IP11 NEMA Type 1 Drive Cat No Duty Hp Cat No Cat No Cat No Cat No 20BB2P2 Heavy Du
22. 2 2 3 0 1 5 2 0 33 AK R2 047P500 47 0 166 33 14496 10096 1596 14496 1196 4 0 5 0 3 0 3 0 30 AK R2 047P500 47 0 166 33 7996 7996 1196 N A N A 5 5 7 5 4 0 5 0 23 AK R2 030P1K2 30 0 26 52 9096 9096 1096 N A N A 7 5 10 5 5 7 5 23 AK R2 030P1K2 30 0 26 52 66 66 10 N A N A 400 480 Volt AC Input Drives 0 37 0 5 0 25 0 33 68 AK R2 360P500 360 0 086 UE 305 100 47 150 31 0 75 1 0 0 55 0 75 68 AK R2 360P500 360 0 086 17 220 100 23 150 15 1 5 2 0 1 1 1 5 68 AK R2 360P500 360 0 086 17 110 100 12 110 11 2 2 3 0 1 5 2 0 68 AK R2 120P1K2 120 0 26 52 197 100 24 150 16 4 0 5 0 3 0 3 0 68 AK R2 120P1K2 120 0 26 52 124 100 13 124 10 5 5 7 5 4 0 5 0 74 AK R2 120P1K2 120 0 26 52 90 90 10 N A N A 7 5 10 5 5 7 5 74 AK R2 120P1K2 120 0 26 52 66 66 10 N A N A 11 15 7 5 10 44 E 60 0 52 104 9096 9096 1096 N A N A 150 J 11 15 34 31 E 60 0 52 104 6696 6696 1096 N A N A 500 600 Volt AC Input Drives 0 37 0 5 0 25 0 33 117 AK R2 360P500 360 0 086 17 27496 10096 4696 15096 3196 0 75 1 0 0 55 0 75 117 AK R2 360P500 360 0 086 17 25196 10096 2396 15096 1596 1 5 2 0 1 1 1 5 117 AK R2 360P500 360 0 086 17 17296 10096 1196 15096 896 2 2 3 0 1 5 2 0 117 AK R2 120P1K2 120 0 26 52 19396 10096 2496 15096 1696 4 0 5 0 3 0 3 0 80 AK R2 120P1K2 120 0 26 52 18596 10096 1396 15096 996 5 5 7 5 4 0 5 0 80 AK R2 120P1K2 120 0 26 52 141 100 9 141 7 7 5 10 5 5 7 5 80 AK
23. 20BE052A0AYNANCO 3 62 78 104 60 50 20BE062A0ANNANCO 4 77 63 85 94 116 126 75 60 82 60 90 90 120 123 75 55 20BE077A0ANNANCO 5 99 77 109 116 126 138 100 75 98 82 108 123 127 140 90 75 20BE099A0ANNANCO 5 125 99 138 149 188 198 125 100 119 98 131 147 1179 196 110 90 20BE125A0ANNANCO 6 144 125 158 188 216 250 150 125 142 119 156 179 213 238 132 110 20BE144A0ANNANCO 6 Catalog number corresponds to output amps in these columns Drive must be programmed to lower voltage to obtain higher currents shown at right Frame 5 and 6 drives have dual current ratings one for normal duty applications and one for heavy duty applications in parenthesis The drive may be operated at either rating Rating is limited to 40 C surrounding air 325V dc Input Drives 325V dc Input 280V dc Input IP20 NEMA Type 1 Output Amps Normal Heavy Output Amps Normal Heavy DC Pre Frame Cont 1 Min 3 Sec Duty Hp Duty Hp Cont 1 Min 3 Sec Duty kW Duty kW charge Cat No Size 104 80 115 120 175 160 40 30 120 92 132 138 175 175 30 22 Y 20BN104A0ANNANCO 5 130 104 143 156 175 175 50 40 130 104 143 156 175 175 37 30 Y 20BN130A0ANNANCO 5 154 130 169 195 231 260 60 50 177 150 195 225 266 300 45 37 Y 20BN154A0ANNANCO 6 192 154 211 231 288 308 75 60 221 177 243 266
24. 21A Area Fac Area Fac Area Fac Area Fac Area Fac 208V ac Three Phase Drives 2 5 2 7 3 7 0 5 0 33 A X2P2 AO X2P2 AO AO AO AO A26 48 5 5 7 4 1 0 0 75 A X4P2 AO X4P2 AO AO AO AO A26 7 8 10 3 13 8 2 0 1 5 B X6P8 AO X6P8 AO AO AO AO A26 11 12 1 16 5 3 0 2 0 B X9P6 AO X9P6 AO AO AO AO A26 17 5 19 2 26 2 5 0 3 0 C X015 AO X015 AO AO AO AO A26 25 3 27 8 37 9 75 5 0 D X022 A0 X022 AO AO AO AO A26 32 2 37 9 50 6 10 1 5 D X028 A0 X028 AO AO AO AO A26 240V ac Three Phase Drives 2 2 2 4 3 3 0 5 0 33 A B2P2 A0 B2P2 AO AO AO AO A26 4 2 4 8 6 4 1 0 0 75 A B4P2 AO B4P2 AO AO AO AO A26 6 8 9 0 12 2 0 15 B B6P8 AO B6P8 AO AO AO AO A26 9 6 10 6 14 4 3 0 2 0 B B9P6 AO B9P6 AO AO AO AO A26 15 3 17 4 23 2 5 0 3 0 C B015 AO B015 AO AO AO AO A26 22 24 2 33 7 5 5 0 D B022 AO B022 AO AO AO AO A26 28 33 44 10 75 D B028 AO B028 AO AO AO AO A26 480V ac Three Phase Drives 1 1 1 2 1 6 0 5 0 33 A D1P1 AO D1P1 AO AO AO AO A26 2 1 2 4 3 2 1 0 0 75 A D2P1 A0 D2P1 AO AO AO AO A26 3 4 4 5 6 0 2 0 15 A D3P4 AO D3P4 AO AO AO AO A26 5 0 5 5 7 5 3 0 2 0 B D5PO AO D5PO AO AO AO AO A26 8 0 8 8 12 5 0 3 0 B D8PO AO D8PO AO AO AO AO A26 11 12 1 16 5 7 5 5 0 C D011 AO D011 AO AO AO AO A26 14 16 5 22 10 75 C D014 AO D014 AO AO AO AO A26 22 24 2 33 15 10 D D022 AO D022 AO AO AO AO A26 27 33 44 20 15 D D027 AO D027 AO AO AO AO A26 600V ac Three Phase Drives 0 9 1 0 1 4 0 5 0 33 A EOP9 AO EOP9 AO AO AO AO A26 1 7 1 9 2 6 1 0 0 7
25. Allen Bradley PowerFlex Family of AC Drives Catalog Rockwell Automation AC Adjustable Frequency Drives Table of Contents PowerFlex Selection Guide page 4 PowerFlex 4 AC Drives page 7 PowerFlex 40 AC Drives page 13 PowerFlex 40 AC Packaged Drives page 21 ArmorStart page 27 PowerFlex 400 AC Drives page 31 PowerFlex 400 AC Packaged Drives page 39 PowerFlex 70 AC Drives page 45 PowerFlex 70 AC Packaged Drives page 63 PowerFlex 700 AC Drives page 75 PowerFlex 700 AC Packaged Drives page 91 PowerFlex 70 700 Fan and Pump Packages page 103 PowerFlex 700H AC Drives page 115 PowerFlex 700S AC Drives page 123 PowerFlex 7000 Medium Voltage Drives page 147 Drive Software page 149 Technical Services and Support page 153 Important Safety and Product Information page 155 Allen Bradley 1 AC Adjustable Frequency Drives PowerFlex Family of Drives Powerful Performance Flexible Control For motor control applications from low to medium voltage and from simple to complex the Powerflex family of drives from 0 2 kW 0 25 Hp to 6340 kW 8500 Hp offers world class motor control solutions Motor Control Performance Because you have a wide range of control needs PowerFlex offers a variety of motor control technologies from Volts Hertz Control for the simplest applications to Vector Control with patented FORCE Technology which provides excellent low speed zero speed perf
26. Output Line Reactors 480V 60 Hz Three Phase 3 Impedance Output Line Reactor IPOO Open Style IP11 NEMA Type 1 Drive Cat No Duty Hp Cat No Cat No 20CD261 Heavy Duty 150 1321 3R200 B 1321 3RA200 B 20CD261 Normal Duty 200 1321 3RB250 B 1321 3RAB250 B 20CD300 Heavy Duty 200 1321 3RB250 B 1321 3RAB250 B 20CD300 Normal Duty 250 1321 3RB320 B 1321 3RAB320 B 20CD385 Heavy Duty 250 1321 3RB320 B 1321 3RAB320 B 20CD385 Normal Duty 300 1321 3RB400 B 1321 3RAB400 B 20CD460 Heavy Duty 300 1321 3RB400 B 1321 3RAB400 B 20CD460 Normal Duty 350 1321 3R500 B 1321 3RA500 B 20CD500 Heavy Duty 350 1321 3RB400 B 1321 3RAB400 B 20CD500 Normal Duty 450 1321 3R500 B 1321 3RA500 B 20CD590 Heavy Duty 450 1321 3R500 B 1321 3RA500 B 20CD590 Normal Duty 500 1321 3R600 B 1321 3RA600 B 20CD650 Heavy Duty 500 1321 3R600 B 1321 3RA600 B 20CD650 Normal Duty 500 1321 3R750 B 1321 3RA750 B 20CD730 Heavy Duty 500 1321 3R750 B 1321 3RA750 B 20CD730 Normal Duty 600 1321 3R750 B 1321 3RA750 B 20CD820 Heavy Duty 600 1321 3R750 B 1321 3RA750 B 20CD820 Normal Duty 700 1321 3R850 B 1321 3RA850 B 20CD920 Heavy Duty 700 1321 3R850 B 1321 3RA850 B 20CD920 Normal Duty 800 1321 3R1000 B 1321 3RA1000 B 20CD1030 Heavy Duty 800 1321 3R1000 B 1321 3RA1000 B 20CD1030 Normal Duty 900 1321 3R1000 B 1321 3RA1000 B PowerFlex 700H has an integral input line reactor Output line reactors were size
27. S10 Only 2 drive digital outputs S11 Only 2 drive digital outputs S12 Only 2 drive digital outputs S13 S14 B1 815 S15 B2 S14 S16 S17 B1 102 Allen Bradley AC Adjustable Frequency Drives PowerFlex Drive Packages for Fan amp Pump Applications Contents Conformity to Standards this page Description this page Catalog Number Explanation page 105 Product Selection page 107 Factory Installed Options page 110 Conformity to Standards The PowerFlex Drive Packages for Fan and Pump Applications conform to the following Conformity to Drive Packages for Fan and Pump Applications UL Listed Y CSA Certified C UL Y Allen Bradley PowerFlex Fan Pump Family Drive Description PowerFlex Drive Packages for Fan and Pump Applications are PowerFlex 70 and PowerFlex 700 drives packaged with input Disconnect and Contactor Bypass hardware to create pre configured packages A limited factory installed option set is offered to optimize package configurations while providing a versatile and cost effective solution Standard Features PowerFlex AC Drive NEMA Type 1 Wall Mount Package Documentation Standard Options Choice of Human Interface Modules One required Choice of Internal Brake IGBT Choice of Internal Brake Resistor Choice of Communication Modules Choice of Packaging Selection One required 103 AC Adjustable Freque
28. When solid state equipment is repaired it is important that any replacement part be in accordance with the recommendations of the equipment manufacturer Care should be taken to avoid the use of parts which are no longer compatible with other changes in the equipment Also replacement parts should be inspected for deterioration due to shelf life and for signs of rework or wear which may involve factors critical to safety After repair proper start up procedures should be followed Special precautions should be taken to protect personnel from hazards during start up C 5 3 Repair Explanatory Information Supplementary Comments Not part of NEMA Standards Publication No ICS 1 1 Follow manufacturer s instructions exactly when replacing power semiconductors mounted on heatsinks since improper installation may become the source of further difficulties Torque semiconductors or bolts retaining semiconductors to the value specified with a torque wrench Too much pressure against a heatsink can damage a semiconductor while too little can restrict the amount of heat transferred from the semiconductor to the heatsink resulting in operation at higher temperature with decreased reliability Exercise care when removing modules from a system during maintenance Failed modules are frequently returned to the manufacturer for repair Any physical damage sustained during removal may result in more expensive repair or render the module unrepaira
29. o W h I Allen Bradley 3 AC Adjustable Frequency Drives PowerFlex Selection Guide PowerFlex Selection Guide PowerFlex AC Drives Comparison Chart PowerFlex 40 PowerFlex 400 For Fans and Pumps Attributes PowerFlex 4 Catalog Reference 22A 22B 220 N A Ratings 100 120V 0 2 1 1 kW 0 25 1 5 HP 0 4 1 1 kW 0 5 1 5 HP Ratings 200 240V 0 2 3 7 kW 0 25 5 HP 0 4 7 5 kW 0 5 10 HP 2 2 37 kW 3 0 50 HP Ratings 400 480V 0 4 3 7 kW 0 5 5HP N A 0 4 11 kW 0 5 15 HP 2 2 110 kW 3 0 150 HP Ratings 500 600V 0 75 11 kW 1 15 HP N A N A Ratings 690V N A N A Control Performance Volts per Hertz Slip Compensation Volts per Hertz Sensorless Vector Slip Compensation Volts per Hertz Slip Compensation Features Drive OL Protection Ramp Regulation Drive OL Protection Ramp Regulation Drive Overload OL Protection Ramp Regulation Flying Start Standard PID Control Standard PID Control Flying Start Flying Start StepLogic Hand Off Auto Sleep Wake Purge Input Damper Input Ambient Temperature Limit for Enclosure Types IP 20 Open 50 C IP 30 NEMA 1 40 C Flange 50 C IP 20 Open 50 C IP 30 NEMA 1 40 C Flange 50 C IP 30 NEMA 1 45 C Integral RS485
30. 14 12 1 6 1 3 1 4 1 9 0 37 0 5 0 25 0 33 D1P1AOAYNNNCO A 2 1 2 4 3 2 2 1 2 4 3 2 0 75 1 0 0 55 0 75 D2P1AOAYNNNCO A 3 4 4 5 6 0 3 5 4 5 6 0 1 5 2 0 1 1 1 5 D3P4AOAYNNNCO A 5 0 5 5 7 5 5 0 5 5 7 5 2 2 3 0 1 5 2 0 D5POAOAYNNNCO B 8 0 8 8 12 8 7 9 9 13 2 4 0 5 0 3 0 3 0 D8POAOAYNNNCO B 11 12 1 16 5 11 5 13 17 4 5 5 7 5 4 0 5 0 D011A0AYNANCO C 14 16 5 22 15 4 17 2 23 1 7 5 10 5 5 75 D014A0AYNANCO C 22 24 2 33 22 24 2 33 11 15 7 5 10 D022A0AYNANCO D 2T 33 44 30 33 45 15 20 11 15 D027A0AYNANCO D 34 40 5 54 37 45 60 18 5 25 15 20 DO34A0AYNANCO D 40 51 68 43 56 74 22 30 18 5 25 DO40A0AYNANCO D 52 60 80 60 66 90 30 40 22 30 D052A0AYNANCO E 65 78 104 72 90 120 37 50 30 40 D065A0AYNANCO E Catalog code corresponds to output amps in these columns Drive must be programmed to lower voltage to obtain higher currents shown at right 500 600V ac Three Phase Drives IP20 NEMA Type Output Amps Nominal Power Ratings 1 without HIM 600V ac Input Normal Duty Heavy Duty Cat No Cont 1 Min 3 Sec kW Hp kW Hp 20A Frame Size 0 9 1 0 1 4 0 37 0 5 0 25 0 33 EOP9ADAYNNNCO A 1 7 1 9 2 6 0 75 1 0 0 55 0 75 E1P7A0AYNNNCO A 2T 3 6 4 8 18 2 0 14 1 0 E2P7A0AYNNNCO A 3 9 4 3 5 8 2 2 3 0 18 1 5 E3P9A0AYNNNCO B 6 1 6 7 9 1 4 0 5 0 3 0 3 0 E6P1A0AYNNNCO B 9 0 9 9 13 5 5 5 7 5 4 0 5 0 E9POAOAYNNNCO C 11 13 5 18 75 10 5 5 7 5 E011A0AYNNNCO C 17 18 7 25 5 11 15 2 5 10 E017A0AYNNNCO
31. 20DD034 Normal Duty 25 1321 3R35 C 1321 3RA35 C 1321 3R35 C 1321 3RA35 C 20DD040 Heavy Duty 25 1321 3R35 C 1321 3RA35 C 1321 3R45 C 1321 3RA45 C 20DD040 Normal Duty 30 1321 3R45 C 1321 3RA45 C 1321 3R45 C 1321 3RA45 C 20DD052 Heavy Duty 30 1321 3R45 C 1321 3RA45 C 1321 3R55 C 1321 3RA55 C 20DD052 Normal Duty 40 1321 3R55 C 1321 3RA55 C 1321 3R55 C 1321 3RA55 C 20DD065 Heavy Duty 40 1321 3R55 C 1321 3RA55 C 1321 3R80 C 1321 3RA80 C 20DD065 Normal Duty 50 1321 3R80 C 1321 3RA80 C 1321 3R80 C 1321 3RA80 C 20DD077 Heavy Duty 50 1321 3R80 C 1321 3RA80 C 1321 3R80 C 1321 3RA80 C 20DD077 Normal Duty 60 1321 3R80 C 1321 3RA80 C 1321 3R80 C 1321 3RA80 C 20DD096 Heavy Duty 60 1321 3R80 C 1321 3RA80 C 1321 3R80 C 1321 3RA80 C 20DD096 Normal Duty 75 1321 3R100 C 1321 3RA100 C 1321 3R100 C 1321 3RA100 C 20DD125 Heavy Duty 75 1321 3R100 C 1321 3RA100 C 1321 3R100 C 1321 3RA100 C 20DD125 Normal Duty 100 1321 3R130 C 1321 3RA130 C 1321 3R130 C 1321 3RA130 C 20DD140 Heavy Duty 75 1321 3R100 C 1321 3RA100 C 1321 3R100 C 1321 3RA100 C 20DD140 Normal Duty 100 1321 3R130 C 1321 3RA130 C 1321 3R130 C 1321 3RA130 C 20DD156 Heavy Duty 100 1321 3R130 C 1321 3RA130 C 1321 3R130 C 1321 3RA130 C 20DD156 Normal Duty 125 1321 3R160 C 1321 3RA160 C 1321 3R160 C 1321 3RA160 C 20DD180 Heavy Duty 125 1321 3R160 C 1321 3RA160 C 1321 3R160 C 1321 3RA160 C 20DD180 Normal Duty 150 1321 3R200 C 1321 3RA200 C 1321 3R200 C 1321 3RA200 C 20DD248 Heavy Dut
32. 416 416 325 400 315 For use on ungrounded distribution systems 730 730 650 400 355 460 460 385 450 355 Frame 9 drives only 820 820 730 450 400 500 502 460 500 450 920 920 820 500 450 590 590 502 560 500 1K0 1030 920 560 500 650 650 590 630 560 j 750 750 650 710 630 Comm Slot 820 820 750 800 630 Code Version c2 N None ND Rating d 480V 60Hz Input Enclosure k Code Amps ND HD Hp ND HD Code Enclosure 261 261 205 200 150 A IP 21 NEMA Type 1 VO 300 300 245 250 200 Code O Volts 385 385 300 300 250 E aV de 460 460 385 350 300 E TiSV ae 500 500 420 450 350 HM N Nong Code Operator Interface 590 590 520 500 450 OOO Beni Cover 650 650 590 500 500 Full Numeric LOD 730 730 650 600 500 3 Drive Mounted I 820 820 730 700 600 Full Numeric LCD Feedback 920 920 820 800 700 E Door Mount Code Type 1KO 1030 920 900 800 Frame 10 amp up only 0 None 116 AC Adjustable Frequency Drives PowerFlex 700H Product Selection 380 500V ac Three Phase Drives 480V ac Input 380 400V ac Input 1P21 NEMA Type 1 Output Amps Normal Heavy Output Amps Normal Heavy Cat No Duty Duty Duty Duty Frame Cont 1 Min 2 Sec Hp Hp Cont 1 Min 2 Sec kw kW 20CD 480V Size 261 205 287 308 349 349 200 150 261 205 287 308 349 349 132 110 261A0ANNBNNO 9 300 245 330 368 4
33. C 400V ac 3 D 480V ac 3 E 600V ac 3 c1 ND Rating 208V 60 Hz Input Code Amps kW Hp 2P2 2 5 0 37 0 5 4P2 4 8 0 75 1 0 6P8 7 8 1 5 2 0 9P6 11 2 2 3 0 015 17 5 4 0 5 0 022 25 3 5 5 7 5 028 32 2 7 5 10 042 43 11 15 054 62 1 15 20 070 78 2 18 5 25 c2 ND Rating 240V 60 Hz Input Code Amps kW Hp 2r2 2 2 0 37 0 5 4P2 4 2 0 75 1 0 6P8 6 8 1 5 2 0 9P6 9 6 2 2 3 0 015 15 8 4 0 5 0 022 22 5 5 7 5 028 28 7 5 10 042 42 11 15 054 54 15 20 070 70 18 5 25 46 10 11 12 3 A Y Y f g h c3 ND Rating 400V 50 Hz Input Code Amps kW Hp 1P3 1 3 0 37 0 5 2P1 2 1 0 75 1 0 3P5 3 5 1 5 2 0 5P0 5 0 2 2 3 0 8P7 8 7 4 0 5 0 011 11 5 5 5 7 5 015 15 4 7 5 10 022 22 11 15 030 30 15 20 037 37 18 5 25 043 43 22 30 060 60 30 40 072 72 37 50 c4 ND Rating 480V 60 Hz Input Code Amps kW Hp 1 1 0 37 0 5 2Bi 2 1 0 75 1 0 3P4 3 4 1 5 2 0 5P0 5 0 2 2 3 0 8PO 8 0 3 7 5 0 o Ti 5 5 7 5 014 14 7 5 10 022 22 11 15 027 27 15 20 034 34 18 5 25 040 40 22 30 052 52 30 40 065 65 37 50 i j k I c5 ND Rating 600V 60 Hz Input Code Amps kW Hp OP9 0 9 0 37 0 5 jb 1 0 75 1 0 2p 2 7 1 5 2 0 3P9 3 9 2 2 3 0 6P1 6 1 4 0 5 0 9PO 9 0 5 5 7 5 011 11 7 5 10 017 17 11 15 022 22 15 20 027 27 18 5 25 032 32 22 30 041 41 30 40 052 52 37 50 d Enclosure Code Enclosure A Panel Mount IP 20 NEMA Type
34. Pounds square inch psi 14 5 Torque Pound inch Ib in Newton meters Nem 0 113 Newton meters Nem Pound inch Ib in 8 85 Temperature Degrees Fahrenheit F Degrees Celsius C Degrees Celsius C Degrees Fahrenheit F Conversion Formula 5 9 F 32 F C Conversion Formula 9 5 C 32 F F 155 AC Adjustable Frequency Drives Important Safety and Product Information Conformal Coating Offering Rockwell Automation offers a conformal coating solution on selected Allen Bradley products to satisfy customers who demand that their automation equipment have additional protection against corrosive elements such as sulfuric acid chlorine fungus salt and other chemicals and gases Rockwell Automation reviews conformal coating opportunities on an individual basis and provides customer pricing To receive a quote please contact your local Rockwell Automation Sales Office Service and Installation Conditions Unless otherwise noted the products described in this publication are designed to meet usual service and installation conditions as defined in NEMA National Electrical Manufacturers Association Standards Publication Part ICS 1 108 Open style devices must be provided with environmental and safety protection by proper mounting in enclosures designed for specific application conditions See NEMA Standards Publication 250 and IEC Publication 529 as applicable for explanations
35. Splitter Cable AK UO RJ45 Remote Human Interface Module HIM Panel Mount open a one to two Portspliter cable set Description LCD Display Remote Panel Mount Digital Terminating Resistors AK U0 RJ45 Speed Control CopyCat capable IP66 NEMA Type 4X 12 Description 120 Ohm resistor embedded in an RJ45 TRI indoor use only Includes 2 0 meter cable Note Remote 22 HIM C2S connector 2 pieces HIM display and keypad are different than PowerFlex 400 Terminal Block AK UO RJ45 integral keypad See the PowerFlex 400 User Manual for Description RJ45 two position terminal block 5 pieces sop details with two 120 Ohm terminating resistors loose Remote Human Interface Module HIM Handheld DeviceNet Communication Adapter Description LCD Display Remote Handheld Digital Speed Note Requires a Communication Adapter Cover when 22 COMM D Control Full Numeric Keypad CopyCat capable IP30 used with Frame C PowerFlex 400 drives Ordered NEMA Type 1 Includes 1 0 meter cable Panel Mount with 22 HIM A3 Separately optional Bezel Kit Note Remote HIM display and keypad E are different than PowerFlex 400 integral keypad See the ee ee i as Cover when PowerFlex 400 User Manual for details used with Frame C PowerFlax 400 drives Ordered 22 COMM E Remote Handheld Wireless Interface Module with Separately Bluetooth technology IP30 NEMA Type 1 Panel Mount 22 WIM N1 PROFIBUS DP Communication Adapter with optional Bezel Kit en Note
36. as standard 4 inputs and 2 outputs to be used with sensors and actuators for monitoring the application process The ArmorStart s LED status indication and built in diagnostics capabilities allows ease of maintenance and troubleshooting The optional Hand Off Auto HOA keypad allows for local start stop control at the ArmorStart Distributed Motor Controller Allen Bradley The Bulletin 284 ArmorStart Distributed Motor Controller offers short circuit protection per UL508C and IEC 60947 1 The ArmorsStart is rated for local disconnect service by incorporating the Bulletin 140 Motor Protector as the local disconnect eliminating the need for additional components The ArmorStart Distributed Motor Controllers are rated for group motor installations Mode of Operation Volts per Hertz Sensorless Vector Performance This method provides excellent speed regulation and high levels of torque across the entire speed range of the drive and improved speed regulation even as loading increases Basic control yields the most cost effective performance when sensorless vector control is not required 3 0 g 254 20 amp 15 1 0 0 5 0 0 it Per U Torque 0 10 20 30 40 50 60 70 80 90 Frequency Hz 100 ArmorStart with Sensorless Vector Performance 3 Hp High Speed Additional Features 4 Preset Speeds Flying Start Auto Restart Sensorless Vector Control SVC Sensorless vector contro
37. i e nominal HP voltage Step 2 Specify Options The following pages list and describe the available options The listing is divided into simple categories to assist in quickly locating specific needs Some options are horsepower and or voltage specific or will have special rules associated with them Read all Footnotes Example An application requires a variable speed control for an existing 3 Hp 480V ac conveyor motor Both drive and motor will be located in a clean environment Local control is required for programming start stop speed and emergency stop Operation across the line with selection and mode indication at drive is required A system disconnect switch should be available Control power is required Description Cat No Option Code Position Basic Drive w IP 20 NEMA Type 1 Enclosure 21BD5P0A 8 0 Human Interface Module LCD Drive Mounted 3 e User Manual A f w Brake IGBT M g No Brake Resistor N h Filtered w Common Mode Choke A i No Communication Module N j 115V Vector Control D k No Feedback Option 0 Reserved for Future Options NN m Special Options NN n Normal Duty ND p Bypass Manual with D O B Switch B1 Control Power C1 Drive Bypass Fused Disconnect Switch P7 Drive 8 Bypass Mode Pilot Lights S14 Drive Disable Pushbutton S16 21BD5POA3AYNANDONNNN ND B1 C1 P7 S14 S16 94 Allen Bradley AC Adjustable Frequency Drives PowerFlex 700 Pac
38. 0 9 206 100 2 5 150 1 7 4 0 5 0 3 0 3 0 68 20AD DB1 B 115 0 028 0 9 129 100 1 4 129 1 1 5 5 7 5 4 0 5 0 74 20AD DB1 C 115 0 04 0 9 94 94 1 5 N A N A 7 5 10 5 5 7 5 74 20AD DB1 C 115 0 04 0 9 69 69 1 5 N A N A 11 54 7 5 10 44 20AD DB1 D 62 0 036 0 8 87 87 0 8 N A N A 15 20 11 15 31 20AD DB1 D 62 0 036 0 8 64 64 0 8 N A N A 500 600 Volt AC Input Drives 0 37 0 5 0 25 0 33 117 20AD DB1 A 115 0 048 8 3 287 100 25 9 150 17 3 0 75 1 0 0 55 0 75 117 20AD DB1 A 115 0 048 9 0 263 100 12 8 150 8 5 1 5 2 0 141 1 5 117 20AD DB1 A 115 0 048 2 4 243 100 6 4 150 4 3 2 2 3 0 1 5 2 0 117 20AD DB1 B 115 0 028 0 9 20296 10096 2 596 15096 1 796 4 0 5 0 3 0 3 0 80 20AD DB1 B 115 0 028 0 9 19396 10096 1 496 15096 0 996 5 5 7 5 4 0 5 0 80 20AD DB1 C 115 0 04 0 9 14796 10096 1 596 14796 1 096 7 5 10 5 5 7 5 80 20AD DB1 C 115 0 04 0 9 10896 10096 1 196 10896 1 096 11 15 7 5 10 48 N A N A N A N A N A N A N A N A N A 15 20 11 15 48 N A N A N A N A N A N A N A N A N A Duty cycle listed is based on full speed to zero speed deceleration For constant regen at full speed duty cycle capability is half of what is listed Application Type 1 represents maximum capability up to 10096 braking torque where possible Application Type 2 represents more than 10096 braking torque where possible up to a maximum of 15096 Always check resistor ohms aga
39. 096 96 5 55 75 1258 125 5 75 100 156 8 156 6 90 125 180 180 6 110 150 248 248 6 132 200 PowerFlex 700 options only Allen Bradley Position 10 11 12 13 14 A Y N A R f g h i j c3 ND Rating 600V 60Hz Input Code Amps Frame kw HP 3P9 3 9 B 2 2 3 0 6P1 6 1 B 4 0 5 0 9PO 9 0 C 5 5 7 5 011 11 C 7 5 10 017 17 D 11 15 022 22 D 15 20 027 27 D 18 5 25 032 32 D 22 30 041 41 E 30 40 052 52 E 37 50 062 8 62 4 45 60 0778 77 5 55 75 099 5 99 5 75 100 1258 125 6 90 125 1448 144 6 110 150 8 PowerFlex 700 options only d Enclosure Code Enclosure A IP 20 NEMA Type 1 e HIM Code Operator Interface 0 Blank Cover 2 Digital LCD 3 Full Numeric LCD 4 Analog LCD 5 Prog Only LCD f Documentation Code Type A User Manual g Brake IGBT Code w Brake IGBT Y Yes NS No Brake IGBT is standard on PowerFlex 70 Frames B C D and E and optional on PowerFlex 700 Frames 4 5 and 6 8 PowerFlex 700 options only h Internal Brake Resistor Code w Resistor Y Yes N No Brake resistor only available for PowerFlex 70 208V Frames B C amp D 480V Frames B C amp D 600V Frames B and C 15 16 17 18 19 C 0 d X n O i Emission Code CE Filter A Yes Nx No PowerFlex 70 600V ratings only J Comm Slot Code Version C ControlNet Coa
40. 1 15 3 16 8 23 5 0 3 0 17 5 19 3 26 3 4 0 2 2 BO15A0EYNANNNN 1 22 24 2 33 74 5 0 25 3 27 8 38 5 5 4 0 B022A0EYNANNNN 1 28 33 44 10 25 32 2 38 50 6 21 5 5 5 B028A0EYNANNNN 2 42 46 2 63 15 10 48 3 53 1 72 5 14 75 B042A0EYNANNNN 3 52 63 80 20 15 56 64 86 15 11 B052A0EYNANNNN 3 70 78 105 25 20 78 2 86 117 3 18 5 15 B070A0ENNANNNN 4 80 105 136 30 25 92 117 3 156 4 22 18 5 B080A0ENNANNNN 4 104 80 115 120 175 160 40 30 120 92 132 138 175 175 30 22 B104A0ENNANNNN 5 130 104 143 156 175 175 50 40 130 104 143 156 175 175 30 30 B130A0ENNANNNN 5 154 130 169 195 231 260 60 50 177 150 195 225 266 300 45 37 B154A0ENNANNNN 6 192 154 211 231 288 308 75 60 221 177 243 266 308 308 55 45 B192A0ENNANNNN 6 Catalog number corresponds to output amps in this column Drive must be programmed to lower voltage to obtain higher currents shown at right These drives have dual current ratings one for normal duty applications and one for heavy duty applications in parenthesis The drive may be operated at either rating 380 480V ac Three Phase Drives 480V ac Input 380 400V ac Input IP20 NEMA Type 1 Output Amps Output Amps Cat No Normal Heavy Normal Heavy Frame Cont 1 Min 3 Sec Duty Hp Duty Hp Cont 1 Min 3 Sec Duty kW Duty kW 20D Size 2 1 2 4 3 2 1 0 75 2 1 2 4 3 2 0 75 0
41. 1 operating system The distribution media is 3 5 HD floppy disks and the language supported is English 1 Allen Bradley DriveExplorer Software DriveExplorer DriveExplorer software is an easy to use cost effective application that provides you with an intuitive means for monitoring and configuring your Allen Bradley drives and communication adapters DriveExplorer software is available in two different versions DriveExplorer for PC full version with all features DriveExplorer Lite freeware DriveExplorer software is designed for the following Microsoft operating systems Windows 95 Windows 98 Windows ME Windows NT 4 0 or greater Windows 2000 Product Selection No of Application Cat No Licenses DriveExplorer for PC 9306 4EXPO2ENE 1 DriveExplorer Lite NA 1 Download at http www ab com drives driveexplorer A CD is also included with 1203 SSS and 22 SCM 232 Serial Converters Distribution Media All DriveExplorer versions are distributed on CD ROM in the supported language of English 151 AC Adjustable Frequency Drives Drives Software Pocket DriveExplorer Software LE 3 DriveEx plorer Pocket DriveExplorer is an easy to use software tool for monitoring and configuring Allen Bradley drives and communication adapters Pocket DriveExplorer software is available in two different versions both available on the same CD Pocket DriveExplorer
42. 100 1321 3R100 B 1321 3RA100 B 1321 3R100 B 1321 3RA100 B 20BE125 Heavy Duty 100 1321 3R100 B 1321 3RA100 B 1321 3R100 B 1321 3RA100 B 20BE125 Normal Duty 125 1321 3R130 B 1321 3RA130 B 1321 3R130 B 1321 3RA130 B 20BE144 Heavy Duty 125 1321 3R130 B 1321 3RA130 B 1321 3R130 B 1321 3RA130 B 20BE144 Normal Duty 150 1321 3R160 B 1321 3RA160 B 1321 3R160 B 1321 3RA160 B Input line reactors were sized based on the NEC fundamental motor amps Output line reactors were sized based on the VFD rated output currents 88 Allen Bradley AC Adjustable Frequency Drives PowerFlex 700 Input and Output Line Reactors 600V 60 Hz Three Phase 5 Impedance Input Line Reactor Output Line Reactor IPOO Open Style IP11 NEMA Type 1 IPOO Open Style IP11 NEMA Type 1 Drive Cat No Duty Hp Cat No Cat No Cat No Cat No 20BE1P7 Heavy Duty 0 5 1321 3R1 B 1321 3RA1 B 1321 3R2 C 1321 3RA2 C 20BE1P7 Normal Duty 1 1321 3R2 C 1321 3RA2 C 1321 3R2 C 1321 3RA2 C 20BE2P7 Heavy Duty 1 1321 3R2 C 1321 3RA2 C 1321 3R4 D 1321 3RA4 D 20BE2P7 Normal Duty 2 1321 3R4 Dt 1321 3RA4 Dt 1321 3R4 Dt 1321 3RA4 Dt 20BE3P9 Heavy Duty 2 1321 3R4 Dt 1321 3RA4 Dt 1321 3R4 D 1321 3RA4 D 20BE3P9 Normal Duty 3 1321 3R4 D 1321 3RA4 D 1321 3R4 D 1321 3RA4 D 20BE6P1 Heavy Duty 3 1321 3R4 D 1321 3RA4 D 1321 3R8 D 1321 3RA8 D 20BE6P1
43. 1030 560 1K0 1030 900 6P8 7 8 6 8 2 0 A Release pending at date of printing Verify Release pending at date of printing Verify 9P6 11 9 6 3 0 before ordering before ordering 015 17 5 15 8 5 0 022 25 3 22 7 5 028 32 2 28 10 042 48 3 42 15 052 56 52 20 070 78 2 70 25 080 92 80 30 104 120 104 40 130 130 130 50 154 177 154 60 192 221 192 75 260 260 260 100 124 Allen Bradley AC Adjustable Frequency Drives PowerFlex 700S c4 c5 ND Rating ND Rating 600V 60Hz Input 690V 50 Hz Input Code Amps Hp Code Amps Hp 1P7 1 7 1 052 52 45 227 2 7 2 060 60 55 3P9 3 9 3 082 82 75 6P1 6 1 5 098 98 90 9PO 9 7 5 119 119 110 011 11 10 142 142 132 017 17 15 170 170 160 022 22 20 208 208 200 027 27 25 261 261 250 032 32 30 325 325 315 041 41 40 385 385 355 052 52 50 416 416 400 062 62 60 460 4 460 450 077 77 75 502 502 500 099 99 100 590 590 560 125 125 125 650 650 630 144 144 150 750 4 750 710 170 170 150 820 a 820 800 208 208 200 CE Certification testing has not been 261 261 250 performed on 600V class drives 325 325 350 4 Release pending at date of printing Verify 385 385 400 before ordering 416 416 450 460 460 450 f 502 502 500 Documentation 590 590 600 Code Documents 650 4 650 700 E Quick Start Guide 750 750 800 N No Documentation 820 a 820 900 CE Certification testing has not been perf
44. 1270 x 762 x 523 mm 50 0 x 30 0 x 20 6 in Wall Mount 4 4 1422 x 914 x 622 mm 56 0 x 36 0 x 24 5 in Wall Mount 5 5 5 2200 x 800 x 600 mm 86 6 x 31 5 x 23 6 in Floor Standing 6 6 6 2200 x 1000 x 600 mm 86 6 x 39 5 x 23 6 in Floor Standing Factory Installed Options Human Interface Modules HIM Position e Catalog Code 3 Catalog Code A Catalog Code B Catalog Code C Drive Mounted LCD Full Drive Mounted LCD Full Numeric amp Drive Mounted LCD Full Numeric amp Door Door Mounted Bezel w LCD Numeric NEMA Type 1 12 Door Mounted Bezel w Blank Cover Mounted Bezel w LCD Digital Speed Full Numeric NEMA Type 1 NEMA Type 1 NEMA Type 1 Catalog Code E Catalog Code F Catalog Code G Drive Mounted LCD Full Numeric Drive Mounted LCD Full Numeric amp Drive Mounted LCD Full Numeric amp Door Mounted Bezel w LCD Door Mounted LCD Full Numeric amp Door Mounted Programmer Programmer Only NEMA Type 1 NEMA Type 12 Only NEMA Type 12 96 Allen Bradley AC Adjustable Frequency Drives PowerFlex 700 Packaged Drives Programs Documentation Description Position f User Manual Standard Internal Brake IGBT Cat Code Position g Y Std N Std Frame Internal Dynamic Brake Resistors These resistors have a limited duty cycle Refer to the PowerFlex Dynamic Braking Selection Guide to determine if an internal resistor will be sufficient for your application An external resisto
45. 15 20 HP 380 480V ac C2 PC Programming Software ther Option o Op m Description Description Cat No DriveTools SP Software ne Auxiliary Relay Board DriveExplorer Software un Description Field installed kit Expands drive output AK U9 RLB1 9 P 9 capabilities 34 Pocket DriveExplorer Software Allen Bradley AC Adjustable Frequency Drives PowerFlex 400 Isolation Transformers Loose 208V ac Three Phase 60 Hz Secondary PowerFlex 400 Drive Ratings 1P32 NEMA Type 3R Isolation Transformer 208V Primary kw Hp Amps kVA Cat No 2 2 3 0 12 5 0 1321 3TW005 XX 4 0 5 0 17 5 7 5 1321 3TW007 XX 5 5 7 5 24 11 1321 3TW011 XX 75 10 33 14 1321 3TW014 XX 11 15 49 20 1321 3TW020 XX 15 20 65 27 1321 3TW027 XX 18 5 25 75 34 1321 3TW034 XX 230V ac Three Phase 60 Hz Secondary Allen Bradley PowerFlex 400 Drive Ratings IP32 NEMA Type 3R Isolation Transformer 230V Primary 460V Primary 575V Primary kw Hp Amps kVA Cat No Cat No Cat No 2 2 3 0 12 5 0 1321 3TW005 AA 1321 3TW005 BA 1321 3TW005 CA 3 7 5 0 17 5 1 5 1321 3TW007 AA 1321 3TW007 BA 1321 3TW007 CA 5 5 75 24 11 1321 3TW011 AA 1321 3TW011 BA 1321 3TW011 CA 78 10 33 14 1321 3TW014 AA 1321 3TW014 BA 1321 3TW014 CA 11 15 49 20 1321 3TW020 AA 1321 3TW020 BA 1321 3TW020 CA 15 20 65 27 1321 3TW027
46. 177 8 69 3 i IN 13 25 7 00 T 2 73 a x kg EMI ad E n TT 355 1 13 98 13 48 e e 304 8 z 12 00 J WAN 285 8 11 25 Allen Bradtey Y Y pus Powertiex E y X d b 6 35 0 25 I 1 ll Optional mounting bracket orientation amp L amp Allen Bradley 25 AC Adjustable Frequency Drives PowerFlex 40 Packaged Drives Programs Frame C 160 L 457 2 R a rM R 0 63 18 00 MR k a PET gt 177 8 1661 16 74 7 00 5 75 CE eu U A xh es esl A 460 8 U M KU KU M R 18 14 427 2 y 16 82 406 4 2 16 00 e T e Allen Bradley D PowerFiex Z i N Detail 83 0 38 07 D n n d oO et dm en 19 1 0 75 9 127 050 ES 26 Allen Bradley Bulletin 284 ArmorStart Distributed Motor Controllers Bulletin 284 ArmorStart Distributed motor Controller On Machine Starting Solution Variable Frequency AC Drive using PowerFlex Technology Horsepower Range 0 5 5 Hp 0 4 3 3 kW Robust IP67 Nema Type 4 enclosure rating Modular Plug and Play Design Quick Disconnect conne
47. 20BB080 Normal Duty 30 1321 3R80 A 1321 3RA80 A 1321 3R80 A 1321 3RA80 A 20BB104 Heavy Duty 30 1321 3R80 A 1321 3RA80 A 1321 3R80 A 1321 3RA80 A 20BB104 Normal Duty 40 1321 3R100 A 1321 3RA100 A 1321 3R100 A 1321 3RA100 A 20BB130 Heavy Duty 40 1321 3R100 A 1321 3RA100 A 1321 3R100 A 1321 3RA100 A 20BB130 Normal Duty 50 1321 3R130 A 1321 3RA130 A 1321 3R130 A 1321 3RA130 A 20BB154 Heavy Duty 50 1321 3R130 A 1321 3RA130 A 1321 3R130 A 1321 3RA130 A 20BB154 Normal Duty 60 1321 3R160 A 1321 3RA160 A 1321 3R160 A 1321 3RA160 A 20BB192 Heavy Duty 60 1321 3R160 A 1321 3RA160 A 1321 3R160 A 1321 3RA160 A 20BB192 Normal Duty 75 1321 3R200 A 1321 3RA200 A 1321 3R200 A 1321 3RA200 A 20BB260 Heavy Duty 75 1321 3R200 A 1321 3RA200 A 1321 3R200 A 1321 3RA200 A 20BB260 Normal Duty 100 1321 3RB250 A 1321 3RAB250 A 1321 3RB250 A 1321 3RAB250 A Input line reactors were sized based on the NEC fundamental motor amps Output line reactors were sized based on the VFD rated output currents 84 Allen Bradley AC Adjustable Frequency Drives PowerFlex 700 Input and Output Line Reactors 240V 60 Hz Three Phase 5 Impedance Input Line Reactor Output Line Reactor IPOO Open Style IP11 NEMA Type 1 IPOO Open Style IP11 NEMA Type 1 Drive Cat No Duty Hp Cat No Cat No Cat No Cat No 20BB2P2 Heavy Duty 0 33 1321
48. 240V ac Three Phase Drives IP54 NEMA Type IP20 NEMA Type 12 less HIM Output Amps Nominal Ratings 1 less HIM w Fan amp Filter 240V ac Input Normal Duty Heavy Duty Cat No Cat No Cont 1 Min 3 Sec Hp Hp Frame Size Positions b d Positions b d Engineered Drives Program Only 2 2 2 4 3 3 0 5 0 33 0 21B2P2A 21B2P2H 4 2 4 8 6 4 1 0 75 0 21B4P2A 21B4P2H 6 8 9 12 2 1 5 1 21B6P8A 21B6P8H 9 6 10 6 14 4 3 2 1 21B9P6A 21B9P6H 15 3 16 8 23 5 3 1 21B015A 21B015H 22 24 2 33 7 5 5 1 21B022A 21B022H 28 33 44 10 7 5 2 21B028A 21B028H 42 46 2 63 15 10 3 21B042A 21B042H 52 63 80 20 15 3 21B052A 21B052H Base Drive Catalog Number Includes PowerFlex 700 Drive User Manual Allen Bradley 95 AC Adjustable Frequency Drives PowerFlex 700 Packaged Drives Programs Enclosure Dimensions Position d Frame Approximate Dimensions NEMA Type 12 Fan amp Filter NEMA Type 1 Catalog Code NEMA Type 1 Catalog Code Catalog Code H with or A without Line Reactors A with Line Reactors without Line Reactors HxWxD Style 0 amp 1 813 x 610 x 422 mm 82 0 x 24 0 x 16 6 in Wall Mount 2 0 0 965 x 610 x 422 mm 38 0 x 24 0 x 16 6 in Wall Mount 3 965 x 762 x 422 mm 38 0 x 30 0 x 16 6 in Wall Mount 4 1270 x 762 x 422 mm 50 0 x 30 0 x 16 6 in Wall Mount 1 amp 2 1 amp 2 1118 x 610 x 523 mm 44 0 x 24 0 x 20 6 in Wall Mount 3 3
49. 38 x 24 x 16 T 1270 0 x 609 6 x 406 4 50 x 24 x 16 8 1117 6 x 914 4 x 406 4 44 x 36 x 16 9 1270 0 x 914 4 x 406 4 50 x 36 x 16 10 1574 8 x 914 4 x 406 4 62 x 36 x 16 Allen Bradley 73 AC Adjustable Frequency Drives PowerFlex 70 Packaged Drives Programs Option Selection Reference Guide Option Any Base Drive Must Be Used With 1 of a HO H1 H2 H3 H4 H5 C3 or C5 and one of an AA1 AA2 AAS AF or AH Cannot Be Used With AA1 CB DS FB or NP AA2 AA3 AF AH C3 C5 AA2 CB DS FB or NP AA1 AA3 AF AH C3 C5 AA3 CB DS FB or NP AA1 AA2 AF AH C3 C5 AF AA1 AA2 AA3 AH AH CB DS FB or NP AA1 AA2 AAS AF C3 C5 BA AA1 KMx BM1 AA1 BM2 KM LQH LRH BM2 AA1 BM1 KM LQN LRN BR JF BM1 or BM2 600V AC CB DS FB NP 600V AC NEMA Type 1 CF AA1 AA1 AA2 AA3 AH C5 HO H1 H2 H3 H4 C3 H5 C5 AA1 AA2 AA3 AH C3 HO H1 H2 H3 H4 H5 DS CB FB NP D1A AA1 D2A AA1 D2B p AA1 D2C Maximum of two D2x options AATE D2D AA1 D3A AA1 D4A BM1 or BM2 AA1 BA D4B BA AA1 D5A AA1 D6A BA or BM1 or BM2 AA1 ET FASP FB CB DS NP GC Gl GD GP GR GD AA1 GC GI GP GR GDN2 AA1 GP GC GD Gl GR GR AA1 GC GD Gl GP HO C3 C5 H1 H2 H3 H4 H5 H1 C3 C5 HO H2 H3 H4 H5 H2 C3 C5 HO H1 H3 H4 H5 H3 C3 C5 HO H1 H2 H4 H5 H4 C3
50. 3R2 A 1321 3RA2 A 1321 3R2 A 1321 3RA2 A 20BB2P2 Normal Duty 0 5 1321 3R2 A 1321 3RA2 A 1321 3R2 A 1321 3RA2 A 20BB4P2 Heavy Duty 0 75 1321 3R4 B 1321 3RA4 B 1321 3R4 B 1321 3RA4 B 20BB4P2 Normal Duty 1 1321 3R4 B 1321 3RA4 B 1321 3R4 B 1321 3RA4 B 20BB6P8 Heavy Duty 15 1321 3R8 B 1321 3RA8 B 1321 3R8 B 1321 3RA8 B 20BB6P8 Normal Duty 2 1321 3R8 B 1321 3RA8 B 1321 3R8 B 1321 3RA8 B 20BB9P6 Heavy Duty 2 1321 3R8 B 1321 3RA8 B 1321 3R12 B 1321 3RA12 B 20BB9P6 Normal Duty 3 1321 3R12 B 1321 3RA12 B 1321 3R12 B 1321 3RA12 B 20BB015 Heavy Duty 3 1321 3R12 B 1321 3RA12 B 1321 3R18 B 1321 3RA18 B 20BB015 Normal Duty 5 1321 3R18 B 1321 3RA18 B 1321 3R18 B 1321 3RA18 B 20BB022 Heavy Duty 5 1321 3R18 B 1321 3RA18 B 1321 3R25 B 1321 3RA25 B 20BB022 Normal Duty 7 5 1321 3R25 B 1321 3RA25 B 1321 3R25 B 1321 3RA25 B 20BB028 Heavy Duty 7 5 1321 3R25 B 1321 3RA25 B 1321 3R35 B 1321 3RA35 B 20BB028 Normal Duty 10 1321 3R35 B 1321 3RA35 B 1321 3R35 B 1321 3RA35 B 20BB042 Heavy Duty 10 1321 3R35 B 1321 3RA35 B 1321 3R45 B 1321 3RA45 B 20BB042 Normal Duty 15 1321 3R45 B 1321 3RA45 B 1321 3R45 B 1321 3RA45 B 20BB052 Heavy Duty 15 1321 3R45 B 1321 3RA45 B 1321 3R55 B 1321 3RA55 B 20BB052 Normal Duty 20 1321 3R55 B 1321 3RA55 B 1321 3R55 B 1321 3RA55 B 20BB070 Heavy Duty 20 1321 3R55 B 1321 3RA55 B 1321 3R80 B 1321 3RA80 B 20BB070 Normal Duty 25 1321 3R80 B 1321 3RA80 B 1321 3R80 B 1321 3RA80 B 20BB080 Heavy Duty 25 1321 3R80 B 1321 3RA80 B 1321 3R80 B 1321 3RA80 B 20BB080 Nor
51. 5 w Modbus RTU and Metasys N2 Communications Options Integral RS485 Integral RS485 Optional Optional DeviceNet DeviceNet Optional EtherNet IP EtherNet IP DeviceNet PROFIBUS DP PROFIBUS DP EtherNet IP Bluetooth PROFIBUS DP Bluetooth BOE Optional network for use only with External DSI Communications Kit PowerFlex 70 Enhanced Control 20A N A 0 37 18 5 kW 0 5 25 HP 0 37 37 kW 0 5 50 HP 0 37 37 kW 0 5 50 HP N A Vector Control VC w FORCE Technology Sensorless VC Slip Compensation Encoder Speed Control Encoderless Speed Control Torque Regulation Volts per Hertz User Sets Multi Language Adv Drive OL Protection Adv Bus Regulation Adv PID Control Spd or Trq Droop Analog Trim Invert Adv Flying Start Motor OL Protection DriveGuard Safe Off Flux Braking NEMA 1 IP 20 Open 50 C Flange 50 C NEMA 4X 12 IP 66 40 C DeviceNet ControlNet Coax ControlNet Fiber EtherNet IP Remote 1 0 RS485 DF1 PROFIBUS DP Interbus LonWorks Modbus RTU Metasys N2 Siemens P1 FLN Bluetooth 4 3 Allen Bradley PowerFlex 700 Vector Control 20B N A 0 37 55 kW 0 5 100 HP 0 37 132 kW 0 5 200 HP 0 75 110 kW 1 150 HP 45 132 kW Vector Control VC w FORCE Technology Sensorless VC Slip Compensation Encoder Speed Control Encoderless Speed Control Torque Regulat
52. 51 Feet 22 HIM H30 The 22 HIM C2S is smaller than the 22 HIM C2 and cannot be used as a direct replacement Spare Parts Description Fan Replacement Kit Frame A Cat No Communication Option Kits Description Cat No Serial Converter Module RS485 to RS232 Description Provides serial communication via DF1 protocol for use with DriveExplorer and DriveExecutive software 22 SCM 232 Includes DSI to RS232 serial converter 1203 SFC serial cable 22 RJ45CBL C20 cable and DriveExplorer Lite CD Serial Cable Description 2 0 meter serial cable with a locking low profile 1203 SFC connector to connect to the serial converter and a 9 pin sub miniature D female connector to connect a computer Null Cable Converter Description For use when connecting the serial converter 1203 SNM to DriveExplorer on a handheld PC DSI Cable Description 2 0 meter RJ45 to RJ45 cable male to male d connectors Splitter Cable AK UO RJ45 Description RJ45 one to two port splitter cable SC1 Terminating Resistors An S Description 120 Ohm resistor embedded in an RJ45 AK en connector 2 pieces Terminal Block Description RJ45 two position terminal block 5 pieces AE E with two 120 Ohm terminating resistors loose External DSI Communications Kit Description External mounting kit for 22 COMM D E and 22 XCOMM P DC BASE External Comms Power Supply E 2 Description Optional 100 240V ac Power Supply
53. 6 5 5 8 15 10 D D022 3 4 6 7 5 6 10 20 15 D D027 3 4 6 7 5 6 10 600V ac Three Phase Drive Enclosure Selection 0 5 0 33 A EOP9 1 4 5 5 4 5 5 1 0 0 75 A EIP7 1 4 5 5 4 5 5 2 0 1 0 A EST 1 4 5 5 4 5 6 3 0 1 5 B ESP9 1 4 5 6 4 5 7 5 0 3 0 B E6P1 1 4 5 6 4 5 7 75 5 0 C E9PO 2 4 5 6 4 5 8 10 7 5 C E011 2 4 5 6 B 5 8 15 10 D E017 3 4 6 T 5 6 10 20 15 D E022 3 4 6 7 5 6 10 Drive in a box includes viewing window as standard flange mount drive drive mounted HIM and drive mounted comm Indoor only Includes flange mount drive drive mounted options or door mounted HIM and one drive input option CB DS FB or NP No viewing window is provided Indoor only t Same as footnote plus all options less line reactor 8 Same as footnote plus all options Includes flange mount drive drive mounted options and one drive input option CB DS FB or NP No viewing window or door mounted HIM provided Outdoor gt Same as footnote plus all options less line reactor Same as footnote plus all options 72 Allen Bradley AC Adjustable Frequency Drives PowerFlex 70 Packaged Drives Programs PowerFlex 70 Configured Drive Enclosure Dimensions Dimensions Style mm in 1 457 2 x 304 8 x 304 8 18x 12x 12 2 457 2 x 406 4 x 304 8 18x 16 x 12 3 558 8 x 406 4 x 304 8 22 x 16 x 12 4 812 8 x 330 2 x 304 8 32 x 13x 12 5 812 8 x 609 6 x 406 4 32 x 24 x 16 6 965 2 x 609 6 x 406 4
54. 70 Packaged Drives Programs PowerFlex 70 Quick Ship Program The Quick Ship Program order entry system has been simplified minimizing the time required to place an order To enter your order type in the first 14 characters of the string and the system will complete the rest Quick Ship Catalog Entry Approx Normal Heavy Dimensions Weight Frame Duty Hp Duty Hp Type in Cat No Name Plated Cat No in lb IP20 NEMA Type 1 480V A 2 0 1 5 21AQD3P4 AA DS 21AQD3P4 AA DS C3 CF D1A D2A D2B D3A JF JR 32h x 24w x 16d 225 B 5 0 3 0 21AQD8P0 AA DS 21AQD8P0 AA DS C3 CF D1A D2A D2B D3A JF JR 32h x 24w x 16d 225 C 10 7 5 21AQD014 AA DS 21AQD014 AA DS C3 CF D1A D2A D2B D3A JF JR 32h x 24w x 16d 235 D 20 15 21AQD027 AA DS 21AQD027 AA DS C3 CF D1A D2A D2B D3A JF JR 38h x 24w x 16d 250 IP65 NEMA Type 4 12 480V A 2 0 1 5 21AQD3P4 AF DS 21AQD3P4 AF DS C3 CF D1A D2A D2B D3A JF JR 32h x 24w x 16d 225 B 5 0 3 0 21AQD8P0 AF DS 21AQD8P0 AF DS C3 CF D1A D2A D2B D3A JF JR 32h x 24w x 16d 225 C 10 7 5 21AQD014 AF DS 21AQD014 AF DS C3 CF D1A D2A D2B D3A JF JR 32h x 24w x 16d 235 D 20 15 21AQD027 AF DS 21AQD027 AF DS C3 CF D1A D2A D2B D3A JF JR 38h x 24w x 16d 250 Supports the Standard Control version of the PowerFlex 70 Note Consult factory for orders larger than 1 drive per frame size PowerFlex 70 Packaged Drives Programs How to Order Step 1 Select the basic PowerFlex 70 drive catalog number b
55. 770 350 300 460 385 506 578 770 770 250 200 D460A0ENNBNNNN 10 500 420 550 630 750 840 450 350 500 420 550 630 750 840 250 200 D500A0ENNBNNNN 10 590 520 649 780 1040 1040 500 450 590 520 649 780 1040 1040 315 250 D590A0ENNBNNNN 11 650 590 715 885 1180 1180 500 500 650 590 715 885 1180 1180 355 315 D650A0ENNBNNNN 11 730 650 803 945 1095 1260 600 500 730 650 803 945 1095 1260 400 355 D730A0ENNBNNNN 11 Catalog number corresponds to output amps in this column Drive must be programmed to lower voltage to obtain higher currents shown at right These have dual current ratings one for normal duty applications and one for heavy duty in parenthesis The drive may be operated at either rating t 380 400V 85 A rating is limited to 45 C surrounding air 380 400V 205 A rating is limited to 40 C surrounding air Rating is limited to 40 C surrounding air Allen Bradley 133 AC Adjustable Frequency Drives PowerFlex 700S 600 690V ac Three Phase Drives 600V ac Input 690V ac Input IP20 NEMA Type 1 Output Amps Normal Heavy Duty Output Amps Normal Heavy Duty Cat No Frame Cont 1 Min 3 Sec Duty Hp Hp Cont 1 Min 3 Sec Duty kW kw 20D Size 22 25 5 34 20 15 E022A0ENYANNNN 2 27 33 44 25 20 E027A0ENYANNNN 2 32
56. 965 2 x 609 6 x 406 4 38 x 24 x 16 Style 6 AF AH NIA Description Factor gt 1270 0 x 609 6 x 406 4 50 x 24 x 16 Style 7 AF AH Motor Heater Control 120V AC 180 W 1117 6 x 914 4 x 406 4 44 x 36 x 16 Style 8 AH Remote Power MH3 A10 1270 0 x 914 4 x 406 4 50 x 36 x 16 Style 9 AH gt Applies to NEMA Type 1 enclosures only 1574 8 x 914 4 x 406 4 62 x 36 x 16 Style 10 AH 3 Requires user supplied control power Door Mounted Options Area Description Factor Drive Bypass Motor Run Time Meter Elapsed Hours Non Resettable Nameplate Door Mounted 158 8 x 50 8 mm 6 25 x F 2 in white Lamacoid with black letters ET AO Requires user supplied control power or the CF option Applies to NEMA Type 1 enclosures only Actual message to be defined by user at order entry otherwise will be supplied blank Operator Devices The operator devices listed below are logically grouped into sets Only one option code selection may be made from Set D4 Where possible 800EP style devices will be supplied mounted and wired Loose or individual devices are not available Description Option M H P B Mushroom Head Push Option Area Set Button Code Factor gt D1 Hand Off Auto Start Stop Speed Ref DIA A1 D2 Drive Pilot Lights See Drive Digital Output Options D3 Control Power On Pilot Light D3A A1 Drive Mode amp Bypass Mode Pilot Lights D4Ax A1 D4 a pice la On amp Bypass Mod
57. A Standard D Optional B Standard C 380 480V ac A Standard D Standard E Internal CE filters are not available for PowerFlex 70 A Frame drives If an A Frame rating is ordered with an internal filter option it will be supplied in a B Frame Internal Communication Adapters Cat Code Description Position j ControlNet C DeviceNet D Remote I O R EtherNet I P E RS485 DF 1 S RS485 HVAC H Control Options Cat Code Description Position k Enhanced Control without DriveGuard C Enhanced Control with DriveGuard G Standard Control N Feedback Options Cat Code Description Position I None Standard Control N None Enhanced Control 0 5V 12V Encoder Enhanced Control wy 1 Allen Bradley AC Adjustable Frequency Drives PowerFlex 70 Packaged Drives Programs Overview The PowerFlex 70 Packaged Drives Program allows users to create drive packages based on their specific needs This program enhances stand a lone drive functionality through additional control power and packaging options which are ideal for OEM and end users with special installation needs The program has three levels Quick Ship Quick Ship products are intended to meet faster than normal delivery requirements Pre defined catalog strings are offered to support shipping one to three business days from date of order entry The current offering is based on NEMA 1 IP20 and NEMA 4 12 IP65 480V
58. AA 1321 3TW027 BA 1321 3TW027 CA 18 5 25 75 34 1321 3TW034 AA 1321 3TW034 BA 1321 3TW034 CA 22 30 90 40 1321 3TW040 AA 1321 3TW040 BA 1321 3TW040 CA 30 40 120 51 1321 3TW051 AA 1321 3TW051 BA 1321 3TW051 CA 37 50 145 63 1321 3TH063 AA 1321 3TH063 BA 460V ac Three Phase 60 Hz Secondary PowerFlex 400 Drive Ratings 1P32 NEMA Type 3R Isolation Transformer 230V Primary 460V Primary 575V Primary kw Hp Amps kVA Cat No Cat No Cat No 2 8 3 0 6 0 5 0 1321 3TW005 AB 1321 3TW005 BB 1321 3TW005 CB 4 0 5 0 10 5 7 5 1321 3TW007 AB 1321 3TW007 BB 1321 3TW007 CB 5 5 7 5 12 11 1321 3TW011 AB 1321 3TW011 BB 1321 3TW011 CB 78 10 17 14 1321 3TW014 AB 1321 3TW014 BB 1321 3TW014 CB 11 15 22 20 1321 3TW020 AB 1321 3TW020 BB 1321 3TW020 CB 15 20 30 27 1321 3TW027 AB 1321 3TW027 BB 1321 3TW027 CB 18 5 25 38 34 1321 3TW034 AB 1321 3TW034 BB 1321 3TW034 CB 22 30 45 5 40 1321 3TW040 AB 1321 3TW040 BB 1321 3TW040 CB 30 40 60 51 1321 3TW051 AB 1321 3TW051 BB 1321 3TW051 CB 37 50 72 63 1321 3TH063 AB 1321 3TH063 BB 45 60 88 75 1321 3TH075 AB 1321 3TH075 BB 55 75 105 93 1321 3TH093 AB 1321 3TH093 BB 75 100 142 118 1321 3TH118 AB 1321 3TH118 BB 90 125 170 145 1321 3TH145 AB 1321 3TH145 BB 110 150 208 175 1321 3TH175 AB 1321 3TH175 BB 35 AC Adjustable Frequency Drives PowerFlex 400 Input and Output Line Reactors Loose 208V 60 Hz Three Phase PowerFlex 400 Ratings IPOO Open Style 1P11 NEMA Type 1
59. C surrounding air 3 Rating is limited to 35 C surrounding air Release pending at date of printing Verify before ordering Allen Bradley 127 AC Adjustable Frequency Drives PowerFlex 700S 600 690V ac Three Phase Drives 600V ac Input 690V ac Input IP20 NEMA Type 1 Output Amps Normal Heavy Output Amps Normal Heavy Cat No Frame Cont 1 Min 3 Sec Duty Hp Duty Hp Cont 1 Min 3 Sec Duty kW Duty kW 20D Size Ta 2 0 2 6 1 0 5 E1P7AOEYNANANE 1 2 7 3 6 4 8 2 1 E2P7AOEYNANANE 1 3 9 4 3 5 9 3 2 ESP9AOEYNANANE 1 6 1 6 7 9 2 5 3 E6P1AOEYNANANE 1 9 9 9 13 5 T5 5 E9POAOEYNANANE 1 11 13 5 18 10 7 5 E011A0EYNANANE 1 17 18 7 25 5 15 10 EO17AOEYNANANE 1 22 25 5 34 20 15 EO22AOEYNANANE 2 27 33 44 25 20 E027A0EYNANANE 2 32 40 5 54 30 25 EO32AOEYNANANE 3 41 48 64 40 30 E041A0EYNANANE 3 52 61 5 82 50 40 E052AO0EYNANANE 3 62 78 104 60 50 EO62AOEYNANANE 4 77 63 85 94 116 126 75 60 82 60 90 90 120 123 75 55 E077A0ENNANANE 5 99 77 109 116 126 138 100 75 98 82 108 123 127 140 90 75 EO99ADENNANANE 5 125 99 138 149 188 198 125 100 119 98 131 147 179 196 110 90 E125A0ENNANANE 6 144 125 158 188 216 250 150 125 142 11
60. C5 amp 396 Line Reactor Mounted in Enclosure Input L1 Output L2 Option C1 or C5 must be selected Allen Bradley AC Adjustable Frequency Drives PowerFlex 700 Packaged Drives Programs Technical Information for Thermal Overload Relays Class 10 Bulletin 193 Relays Will trip in 10 seconds or less at 600 of device current rating Trip setting is adjustable per the range chart shown Range is chosen to cover maximum drive current rating f a motor outside the published adjustability range is to be used enter customer order and provide complete motor data 480V AC Three Phase Drives Drive Rating ND Drive Rating HD Class 10 Adjustable Thermal Overload Relay Electronic Adjustable Range Amps Hp Hp Normal Duty Heavy Duty 0 5 0 33 1 0 2 9 0 32 1 0 1 0 75 1 0 2 9 1 0 2 9 2 1 5 1 6 5 0 1 6 5 0 3 2 1 6 5 0 1 6 5 0 5 3 3 7 12 1 6 5 0 75 5 3 7 12 3 7 12 10 7 5 12 32 3 7 12 15 10 13 37 13 37 20 15 13 37 13 37 25 20 13 37 13 37 30 25 14 45 14 45 40 30 26 85 26 85 50 40 26 85 26 85 60 50 26 85 26 85 75 60 66 110 26 85 100 75 57 180 66 110 125 100 57 180 57 180 150 125 57 180 57 180 200 150 96 300 57 180 240V AC Three Phase Drives Drive Rating ND Drive Rating HD Class 10 Adjustable Thermal Overload Relay Electronic Adjustable Range Amps
61. Catalog code corresponds to output amps in these columns Drive must be programmed to lower voltage to obtain higher currents shown at right 500 600V ac Three Phase Drives Flange Type without Output Amps Nominal Power Ratings HIM 600V ac Input Normal Duty Heavy Duty Cat No Cont 1 Min 3 Sec kW Hp kw Hp 20A Frame Size 0 9 1 0 1 4 0 37 0 5 0 25 0 33 EOPSFOAYNNNCO JA 1 7 1 9 2 6 0 75 1 0 0 55 0 75 E1P7FOAYNNNCO JA 24 3 6 4 8 15 2 0 1 1 1 0 E2P7FOAYNNNCO JA 3 9 4 3 5 8 22 3 0 1 5 15 ESP9FOAYNNNCO B 6 1 6 7 9 1 4 0 5 0 3 0 3 0 E6P1FOAYNNNCO B 9 0 9 9 13 5 5 5 7 5 4 0 5 0 E9POFOAYNNNCO C 11 13 5 18 75 10 5 5 75 EO11FOAYNNNCO C 17 18 7 25 5 11 15 7 5 10 E017FOAYNNNCO D 22 25 5 34 15 20 11 15 EO22FOAYNNNCO D 27 33 44 18 5 25 15 20 E027FOAYNNNCO D 32 40 5 54 22 30 18 5 25 E032FOAYNNNCO D 41 48 64 30 40 22 30 E041FOAYNANCO E 52 61 5 82 37 50 30 40 E052FOAYNANCO E 52 Allen Bradley AC Adjustable Frequency Drives PowerFlex 70 User Installed Options Human Interface and Wireless Interface Modules LCD Digital Speed 20 HIM A2 LCD Programmer Only 20 HIM A5 Remote Panel Mount Full Numeric 20 HIM C3 Us Remote Panel Mount Programmer Only DPI NEMA 4 WIM Remote Panel Mount 20 WIM N4S LCD Full Numeric 20 HIM A3 DPI NEMA 1 WIM 20 WIM N1 Remote Panel Mount Full Numeric 20 HIM C3S Remote Panel Mount Programmer Only Human Interface Module A
62. Descriptions of IEC Enclosure Test Requirements below and on page Important 11 For complete test requirements refer to IEC 529 First Numeralx Protection of persons against access to hazardous parts and protection against penetration of solid foreign objects Second Numeral Protection against ingress of water under test conditions specified in IEC 529 Non protected Non protected Back of hand objects greater than 50 mm in diameter Vertically falling drops of water Finger objects greater than 12 5 mm in diameter Vertically falling drops of water with enclosure tilted 15 degrees Tools or objects greater than 2 5 mm in diameter Spraying water Tools or objects greater than 1 0 mm in diameter Splashing water Dust protected dust may enter during specified test but must not interfere with operation of the equipment or impair safety Water jets Dusttight no dust observable inside enclosure at end of test Powerful water jets Temporary submersion Continuous submersion Example IP41 describes an enclosure that is designed to protect against the entry of tools or objects greater than 1 mm in diameter and to protect against vertically dripping water under specified test conditions Note All first numerals and second numerals up to and including characteristic numeral 6 imply compliance also with the requirements for all lower characteristic numerals in thei
63. Drives 480V ac Input 380 400V ac Input IP20 NEMA Type 1 Output Amps Normal Heavy Output Amps Normal Heavy Cat No Frame Cont 1 Min 3 Sec Duty Hp Duty Hp Cont 1 Min 3 Sec Duty kw Duty kw 20D Size 2 1 2 4 3 2 1 0 75 2 1 2 4 3 2 0 75 0 55 D2P1AOEYNANANE 1 3 4 4 5 6 2 1 5 3 5 4 5 6 1 5 0 75 D3P4A0EYNANANE 1 5 5 5 To 3 2 5 5 5 75 22 1 5 D5POAOEYNANANE 1 8 8 8 12 5 3 8 7 9 9 13 2 4 2 2 D8POAOEYNANANE 1 11 12 1 16 5 7 5 5 11 5 13 17 4 5 5 4 DO11AOEYNANANE 1 14 16 5 22 10 Ta 15 4 17 2 23 1 7 5 5 5 DO14A0EYNANANE 1 22 24 2 33 15 10 22 24 2 33 11 7 5 D022AO0EYNANANE 1 27 33 44 20 15 30 33 45 15 11 D027A0EYNANANE 2 34 40 5 54 25 20 37 45 60 18 5 15 DO34A0EYNANANE 2 40 51 68 30 25 43 56 74 22 18 5 DO40A0EYNANANE 3 52 60 80 40 30 56 64 86 30 22 D052AO0EYNANANE 3 65 78 104 50 40 72 84 112 37 30 DO65A0EYNANANE 3 77 65 85 98 116 130 60 50 85 72 94 108 128 144 45 37 D077A0ENNANANE 4 96 77 106 116 144 154 75 60 105 85 116 128 158 170 55 45 DO96A0ENNANANE 5 125 96 138 144 163 168 100 75 125 96 138 144 163 168 55 45 D125A0ENNANANE 5 156 125 172 188 233 250 125 100 170 140 187 210 255 280 90 75 D156A0ENNANANE 6 180 156 198 234 270 3812 150 125 205 170 220 255 289 313 110 90 D180A0ENNANANE 6 248 180 273 270 372 3
64. Duty 0 33 1321 3R1 C 1321 3RA1 C 1321 3R2 B 1321 3RA2 B 20BD1P1 Normal Duty 0 5 1321 3R1 C 1321 3RA1 C 1321 3R2 B 1321 3RA2 B 20BD2P1 Heavy Duty 0 75 1321 3R2 A 1321 3RA2 A 1321 3R2 A 1321 3RA2 A 20BD2P1 Normal Duty 1 1321 3R2 A 1321 3RA2 A 1321 3R2 A 1321 3RA2 A 20BD3P4 Heavy Duty 1 5 1321 3R4 C 1321 3RA4 C 1321 3R4 B 1321 3RA4 B 20BD3P4 Normal Duty 2 1321 3R4 B 1321 3RA4 B 1321 3R4 B 1321 3RA4 B 20BD5PO Heavy Duty 2 1321 3R4 B 1321 3RA4 B 1321 3R8 C 1321 3RA8 C 20BD5PO Normal Duty 3 1321 3R8 C 1321 3RA8 C 1321 3R8 C 1321 3RA8 C 20BD8P0 Heavy Duty 3 1321 3R8 C 1321 3RA8 C 1321 3R8 B 1321 3RA8 B 20BD8PO Normal Duty 5 1321 3R8 B 1321 3RA8 B 1321 3R8 B 1321 3RA8 B 20BD011 Heavy Duty 5 1321 3R8 B 1321 3RA8 B 1321 3R12 B 1321 3RA12 B 20BD011 Normal Duty 7 5 1321 3R12 B 1321 3RA12 B 1321 3R12 B 1321 3RA12 B 20BD014 Heavy Duty 7 5 1321 3R12 B 1321 3RA12 B 1321 3R18 B 1321 3RA18 B 20BD014 Normal Duty 10 1321 3R18 B 1321 3RA18 B 1321 3R18 B 1321 3RA18 B 20BD022 Heavy Duty 10 1321 3R18 B 1321 3RA18 B 1321 3R25 B 1321 3RA25 B 20BD022 Normal Duty 15 1321 3R25 B 1321 3RA25 B 1321 3R25 B 1321 3RA25 B 20BD027 Heavy Duty 15 1321 3R25 B 1321 3RA25 B 1321 3R25 B 1321 3RA25 B 20BD027 Normal Duty 20 1321 3R35 B 1321 3RA35 B 1321 3R25 B 1321 3RA25 B 20BD034 Heavy Duty 20 1321 3R35 B 1321 3RA35 B 1321 3R35 B 1321 3RA35 B 20BD034 Normal Duty 25 1321 3R35 B 1321 3RA35 B 1321 3R35 B 1321 3RA35 B 20BD040 Heavy Duty 25 1321 3R35 B 1321 3RA35 B 1321 3R45 B 1321 3RA45 B 20BD040 Nor
65. Fax 1 414 212 5201 Headquarters for Allen Bradley Products Rockwell Software Products and Global Manufacturing Solutions Americas Rockwell Automation 1201 South Second Street Milwaukee WI 53204 2496 USA Tel 1 414 382 2000 Fax 1 414 382 4444 Europe Middle East Africa Rockwell Automation SA NV Vorstlaan Boulevard du Souverain 36 1170 Brussels Belgium Tel 32 2 663 0600 Fax 32 2 663 0640 Asia Pacific Rockwell Automation 27 F Citicorp Centre 18 Whitfield Road Causeway Bay Hong Kong Tel 852 2887 4788 Fax 852 2508 1846 Headquarters for Dodge and Reliance Electric Products Americas Rockwell Automation 6040 Ponders Court Greenville SC 29615 4617 USA Tel 1 864 297 4800 Fax 1 864 281 2433 Europe Middle East Africa Rockwell Automation Br hlstraBe 22 D 74834 Elztal Dallau Germany Tel 49 6261 9410 Fax 49 6261 17741 Asia Pacific Rockwell Automation 55 Newton Road 11 01 02 Revenue House Singapore 307987 Tel 65 6356 9077 Fax 65 6356 9011 U S Allen Bradley Drives Technical Support Tel 1 262 512 8176 Fax 1 262 512 2222 Email supportOdrives ra rockwell com Online www ab com support abdrives Publication D115 CA001B EN P May 2005 Copyright 2005 Rockwell Automation All rights reserved Printed in USA Supersedes D115 CA001A EN P May 2004
66. Hp Hp Normal Duty Heavy Duty Engineered Drives Program Only 0 5 0 33 1 0 2 9 1 0 2 9 1 0 75 1 6 5 0 1 6 5 0 2 1 5 3 7 12 3 7 12 3 2 3 7 12 3 7 12 5 3 12 32 3 7 12 7 5 5 12 32 12 32 10 7 5 13 37 13 37 15 10 14 45 14 45 20 15 26 85 26 85 25 20 30 25 40 30 50 40 60 50 75 60 100 75 125 100 150 125 99 AC Adjustable Frequency Drives PowerFlex 700 Packaged Drives Programs Control Interface amp Feedback Options Option Description Code Analog Inputs Outputs Isolated Analog Input 0 10V dc N1 amp Isolated Analog Input 4 20 mA N2 Isolated Analog Output 0 10V dc N3 Control Relay Option Control Power On J1 Auxiliary Contacts 2 Form C 2 N O 2 N C Drive Fault J2 Alarm J3 Drive Run J4 At Speed J5 Programmable Relay A J6 Programmable Relay B J7 Building Management Control Interface N5 6 Communication Options Panel Mounted Johnson Controls Metasys Interface G1 Maximum of two drive digital options can be selected NOTE S9 J4 One Digital Output S10 J2 One Digital Output S11 J5 One Digital Output S12 J3 One Digital Output All other combinations One Digital Output This requires option C1 or user supplied 115V option C5 Motor Interface Options Option Description Code Motor Heater Control J8 Requires user supplied control power Oper
67. Interface Options Bypass and Bypass Options Power Conditioning Options Motor Interface Options Order Specific Documentation Additional Custom Capabilities IP 20 NEMA 1 0 to 40 C IP 65 NEMA 4 12 indoor 0 to 40 C IP 54 NEMA 12 Fan amp Filter 0 to 40 C IP 65 NEMA 4 outdoor 0 to 40 C DeviceNet ControlNet Coax ControlNet Fiber EtherNet IP Remote 1 0 RS485 DF1 PROFIBUS DP Interbus LonWorks Modbus RTU Metasys N2 Siemens P1 FLN Bluetooth DeviceNet ControlNet Coax ControlNet Fiber EtherNet IP Remote 1 0 RS485 DF1 PROFIBUS DP Interbus Modbus RTU Bluetooth Allen Bradley AC Adjustable Frequency Drives PowerFlex 4 Contents Standard Product Description this page Conformity to Standards this page Catalog Number Explanation page 8 Product Selection page 9 User Installed Options page 10 Conformity to Standards PowerFlex 4 drives conform to the following Conformity to UL Listed Standard Product IEC Designed to Meet CE Approved C Tick Allen Bradley JEJEJE PowerFlex 4 AC Drive Drive Description PowerFlex 4 drives are designed to worldwide standards and ratings allowing out of the box performance around the globe Drives are available in two frame sizes that cover ratings from 0 2 to 3 7 kW 0 25 to 5 Hp 100 to 120 volts 200 to 240 volts and 380 to 480 volts Drives feature integral RS485 communications and are
68. NEMA 1 IP30 is required must also order 22 JBCB Frame B drives or 22 JBCC Frame C drives PC Programming Software Description DriveTools SP Software DriveExplorer Software Pocket DriveExplorer Software See A B publication 9303 PL002 for ordering pricing information 17 AC Adjustable Frequency Drives PowerFlex 40 Dynamic Brake Resistors Drive Ratings Minimum Resistance Input Voltage kW Hp Q Cat No 0 4 0 5 48 AK R2 091P500 ae 0 75 10 48 AK R2 091P500 14 1 5 48 AK R2 091P500 0 4 0 5 48 AK R2 091P500 240V 50 60 Hz 0 75 1 0 48 AK R2 091P500 1 Phase 1 5 2 0 48 AK R2 091P500 2 2 3 0 32 AK R2 047P500 0 4 0 5 48 AK R2 091P500 0 75 1 0 48 AK R2 091P500 1 5 2 0 48 AK R2 091P500 a ME 2 2 3 0 32 AK R2 047P500 3 7 5 0 19 AK R2 047P500 5 5 7 5 13 AK R2 030P1K2 7 5 10 10 AK R2 030P1K2 0 4 0 5 97 AK R2 360P500 0 75 1 0 97 AK R2 360P500 1 5 2 0 97 AK R2 360P500 480V 50 60 Hz 2 2 3 0 97 AK R2 120P1K2 3 Phase 4 0 5 0 77 AK R2 120P1K2 5 5 75 55 AK R2 120P1K2 7 5 10 39 AK R2 120P1K2 11 15 24 AK R2 120P1K2 0 75 1 0 120 AK R2 360P500 1 5 2 0 120 AK R2 360P500 2 2 3 0 82 AK R2 120P1K2 en 4 0 5 0 82 AK R2 120P1K2 5 5 7 5 51 AK R2 120P1K2 7 5 10 51 AK R2 120P1K2 11 15 51 AK R2 120P1K2 Resistors listed in this table are rated 5 duty cycle Requires two resistors wired in parallel 18 Allen Bradley
69. Normal Duty 15 1321 3R25 C 1321 3RA25 C 1321 3R25 C 1321 3RA25 C 20BD027 Heavy Duty 15 1321 3R25 C 1321 3RA25 C 1321 3R25 C 1321 3RA25 C 20BD027 Normal Duty 20 1321 3R35 Ct 1321 3RA35 C 1321 3R25 C 1321 3RA25 C 20BD034 Heavy Duty 20 1321 3R35 Ct 1321 3RA35 C 1321 3R35 C 1321 3RA35 C 20BD034 Normal Duty 25 1321 3R35 C 1321 3RA35 C 1321 3R35 C 1321 3RA35 C 20BD040 Heavy Duty 25 1321 3R35 C 1321 3RA35 C 1321 3R45 C 1321 3RA45 C 20BD040 Normal Duty 30 1321 3R45 C 1321 3RA45 C 1321 3R45 C 1321 3RA45 C 20BD052 Heavy Duty 30 1321 3R45 C 1321 3RA45 C 1321 3R55 C 1321 3RA55 C 20BD052 Normal Duty 40 1321 3R55 C 1321 3RA55 C 1321 3R55 C 1321 3RA55 C 20BD065 Heavy Duty 40 1321 3R55 C 1321 3RA55 C 1321 3R80 C 1321 3RA80 C 20BD065 Normal Duty 50 1321 3R80 C 1321 3RA80 C 1321 3R80 C 1321 3RA80 C 20BD077 Heavy Duty 50 1321 3R80 C 1321 3RA80 C 1321 3R80 C 1321 3RA80 C 20BD077 Normal Duty 60 1321 3R80 C 1321 3RA80 C 1321 3R80 C 1321 3RA80 C 20BD096 Heavy Duty 60 1321 3R80 C 1321 3RA80 C 1321 3R80 C 1321 3RA80 C 20BD096 Normal Duty 75 1321 3R100 C 1321 3RA100 C 1321 3R100 C 1321 3RA100 C 20BD125 Heavy Duty 75 1321 3R100 C 1321 3RA100 C 1321 3R100 C 1321 3RA100 C 20BD125 Normal Duty 100 1321 3R130 C 1321 3RA130 C 1321 3R130 C 1321 3RA130 C 20BD156 Heavy Duty 100 1321 3R130 C 1321 3RA130 C 1321 3R130 C 1321 3RA130 C 20BD156 Normal Duty 125 1321 3R160 C 1321 3RA160 C 1321 3R160 C 1321 3RA160 C 20BD180 Heavy Duty 125 1321 3R160 C 1321 3RA160 C 1321 3R160 C 1321 3RA160 C 20BD1
70. October 1987 is available from the National Electrical Manufacturers Association 2101 L Street N W Washington DC 20037 Allen Bradley Publication SGI 1 1 is available from www rockwellautomation com literature 5 1 General A well planned and executed maintenance program is essential to the satisfactory operation of solid state electrical equipment The kind and frequency of the maintenance operation will vary with the kind and complexity of the equipment as well as with the nature of the operating conditions Maintenance recommendations of the manufacturer or appropriate product standards should be followed Useful reference publications for setting up a maintenance program are NFPA 70B 1983 Maintenance of Electrical Equipment and NFPA 70E 1983 Electrical Safety Requirements for Employee Workplaces 5 2 Preventive Maintenance The following factors should be considered when formulating a maintenance program 1 Maintenance must be performed by qualified personnel familiar with the construction operation and hazards involved with the control 2 Maintenance should be performed with the control out of operation and disconnected from all sources of power If maintenance must be performed while the control is energized the safety related practices of NFPA 70E should be followed 160 3 Care should be taken when servicing electrostatic sensitive components The manufacturer s recommendations for these components should be
71. Products Program Panel Mount IP 20 NEMA Type 1 Position d A The following catalog numbers represent the PowerFlex 70 U S Stock Products Program which offers the shortest lead time and the lowest price on an IP20 NEMA Type 1 drive with a factory installed LCD full numeric HIM but no other factory installed options other than what comes as standard Brake IGBT on all ratings and EMC Filter on some ratings Allen Bradley recommends ordering a Stock Product from this list along with separate user installed options shown immediately following the Standard Drives Section For other enclosure types other factory installed HIMs including no HIM or additional factory installed options refer to Standard Drives Selection section 200 240V ac Three Phase Drives IP20 NEMA Type Output Amps Nominal Power Ratings 1 with HIM 240V ac Input 208V ac Input Normal Duty Heavy Duty Cat No Cont 1 Min 3 Sec Cont 1 Min 3 Sec kw Hp kw Hp 20A Frame Size 2 2 2 4 3 3 2 5 2 7 3 7 0 37 0 5 0 25 0 33 B2P2ASAYNNNCO A 4 2 4 8 6 4 4 8 5 5 7 4 0 75 1 0 0 55 0 75 BA4P2ASAYNNNCO A 6 8 9 0 12 7 8 10 3 13 8 15 2 0 1 1 1 5 B6P8A3AYNNNCO B 9 6 10 6 14 4 11 12 1 16 5 2 2 3 0 1 5 2 0 B9P6A3AYNNNCO B 15 3 17 4 23 2 17 5 19 2 26 2 4 0 5 0 3 0 3 0 BO15A3AYNANCO C 22 24 2 33 25 3 27 8 37 9 5 5 7 5 4 0 5 0 B022A3AYNANCO D 28 33 44 32 2 37 9 50 6 7 5 10 5 5 7 5 BO28A3AYNANCO D 42 4
72. R2 120P1K2 120 0 26 52 103 100 7 103 7 1105 7 5 10 48 ID 60 0 52 104 14196 10096 996 14196 796 15 20 1 11 15 48 E 60 0 52 104 103 100 7 103 7 Duty cycle listed is based on full speed to zero speed deceleration For constant regen at full speed duty cycle capability is half of what is listed Application Type 1 represents maximum capability up to 100 braking torque where possible Application Type 2 represents more than 100 braking torque where possible up to a maximum of 150 Always check resistor ohms against minimum resistance for drive being used For 11 and 15 kW 15 and 20 Hp applications use two 7 5 kW 10 Hp size resistors wired in parallel External Dynamic Brake Resistor Kits Brake Resistance Continous Power Drive Input Voltage Q WwW Cat No 30 260 AK R2 030P1K2 200 240V ac 47 166 AK R2 047P500 91 86 AK R2 091P500 120 260 AK R2 120P1K2 480 600V ac 360 86 AK R2 360P500 Allen Bradley 55 AC Adjustable Frequency Drives PowerFlex 70 Input and Output Line Reactors 240V 60 Hz Three Phase 3 Impedance Input Line Reactor Output Line Reactor IPOO Open Style IP11 NEMA Type 1 IPOO Open Style IP11 NEMA Type 1 Drive Cat No Duty Hp Cat No Cat No Cat No Cat No 20AB2P2 Heavy Duty 0 33 1321 3R2 D 1321 3RA2 D 132
73. Requires a Communication Adapter Cover when 22 COMM P Remote Panel Mount Wireless Interface Module with used with Frame C PowerFlex 400 drives Ordered y Bluetooth technology IP66 NEMA Type 4X 12 indoor use 22 WIM N4S Separately only External DSI Communications Kit 22 XCOMM Bezel Kit Description External mounting kit for 22 COMM D E and DC BASE Description Panel Mount for LCD Display Remote 22 HIM B1 P A Handheld unit IP30 NEMA Type 1 External Comms Power Supply En DSI HIM Cable Description Optional 100 240V ac Power Supply for AC PS1 Description DSI HIM to RJ45 cable External DSI Communications Kit 1 0 Meter 3 3 Feet 22 HIM H10 2 9 Meter 9 51 Feet 22 HIM H30 Compact I O Module 3 Channel 1769 SM2 E n A A REIS Communication Adapter Cover The 22 HIM C2S is smaller than the 22 HIM C2 and cannot be used as a Description Houses the Communication Adapter for Frame direct replacement C drives Note This cover adds 25 mm 0 98 in to the overall depth ARTIE of the drive and is only required for Frame C PowerFlex Spare Parts 400 drives Serial Flash Firmware Kit HH Description Cat No Description Use a PC to update drive firmware USAS PowerFlex 400 Fan Replacement Kit SK U1 FAN1 Description 1 Fan 3 10 HP 200 240V ac and 3 10 2 If NEMA 1 IP30 is required must also order 22 JBCC Frame C drives HP 380 480V ac only PowerFlex 400 Fan Replacement Kit SK U1 FAN1 Description 1 Fan
74. Yes Expanded G Phasel Na No Slim H is N A Yes Slim I Feedback Code Option N None A Resolver B lt Stegman Hi Resolution Encoder Cc Multi Device Interface E 2nd Encoder S Safe Off w 2nd Encoder Expanded cassette required m Additional Config Code Description E Phase Il Control K Phase Il DriveLogix5730 Phase Il DriveLogix5730 w EtherNet IP 125 AC Adjustable Frequency Drives PowerFlex 700S Phase Il Product Selection Slim Cassette Options Embedded EtherNet IP DPI communication 20 Comm xx DriveLogix5730 controller SynchLink Expanded Cassette Options Speed amp Position Feedback devices 2nd Encoder Resolver Stegmann or Heidenhain DriveLogix Expansion board NetLinx Communication 1788 XXXX Compact I O connection CompactFlash Expanded Cassette Compact I O Connection Logix Expansion NetLinx Daughter Card Compact Flash DriveLogix Feedback Run Rem Prog Options Switch 2nd Encoder Option SynchLink Option DriveLogix on Main Board Expanded I O Embedded EtherNet IP Slim Option Cassette 208 240V ac Three Phase Drives 240V ac Input 208V ac Input IP20 NEMA Type 1 Output Amps Normal Heavy Duty Output Amps Normal Heavy Duty Cat No Frame Cont 1 Min 3 Sec Duty Hp Cort 1 Min 3 Sec Duty kW kw 20D Size 4 2 4 8 6 4 1 0 0 75 4 8 5 6 7 0 0 7
75. and Reversing Y Y Current Limit Soft Start including Soft Stop Y Y Sensorless Vector Performance Y Y Sensorless Vector Control Y Y Environmental Rating IP67 NEMA Type 4 Y Y Y Y Y Y Control Voltage Ratings 24V DC 120V AC and 240V AC Y Y Y Y Y Y Operational Voltage Ratings 200 460V AC Y Y Y Y 200 240V AC Y Y 380 480V AC Y Y Rated for Group Motor Installations Y Y Y Y Y Y nn with DeviceNet including Y y Es Y Y Y VO Capability 4 Inputs and 2 Outputs Y Y Y 2 Outputs Y Y Y Network Communications via ArmorPoint Distributed 1 0 _ Y en a Y Products DeviceNet EtherNet ControlNet 1 0 Expansion with ArmorPoint Distributed I O Products Y Y Y Y Y Y LED Status Indication Y Y Y Y Y Y Cni aa I O Communication and Motor Y y Y Y Y Y Extended Length Motor and Brake Cables Y Y Y Y Y Y Factory Installed Options HOA Keypad Y Y Y Y Y Y Safety Monitor Y Y Y Y Y Y Source Brake Contactor Y Y Y Y Dynamic Brake Connector Y Y Output Contactor Y Y EMI Filter Y Y Shielded Motor Cable Y Y 0 10V Analog Input Y Y Product details are not listed in this catalog refer to the Product Selection Guide publication 280 SG001 30 Allen Bradley AC Adjustable Frequency Drives PowerFlex 400 Contents Conformity to Standard P
76. at 65 gallons 246 liters per minute from a 1 in 25 4 mm diameter nozzle directed at all joints from all angles from a distance of 10 to 12 ft 3 to 3 7 meters Test time is 48 seconds times the test length height width depth of enclosure in ft meters or a minimum of 5 seconds No water shall enter enclosure 6 8 Rust Resistance Test Applicable Only to Enclosures Incorporating External Ferrous Parts Enclosure is subjected to a salt spray fog for 24 hours using water with five parts by weight of salt NaCI at 95 F 35 C then rinsed and dried There shall be no rust except where protection is impractical e g machined mating surfaces sliding surfaces of hinges shafts etc 6 9 Corrosion Protection Sheet steel enclosures are evaluated per Underwriter s Laboratories UL 50 Part 13 test for equivalent protection as G 90 commercial zinc coated sheet steel Other materials per Underwriter s Laboratories UL 508 6 9 or 6 10 6 11 2 Air Pressure Test Alternate Method Enclosure is submerged in water at a pressure equal to water depth of 6 ft 2 meters for 24 hours No water shall enter enclosure 6 12 Oil Exclusion Test Enclosure is subjected to a stream of test liquid for 30 minutes from a 3 8 in 9 5 mm diameter nozzle at 2 gallons 7 57 liters a minute Water with 0 1 wetting agent is directed from all angles from a distance of 12 to 18 in 305 to 457 mm while any externally operated
77. bytes 20D DL ME1 Requires Expanded Cassette when used with Phase II Control For use with Phase Il Control ONLY 135 AC Adjustable Frequency Drives PowerFlex 700S DriveLogix I O Cables Description Cat No DriveLogix5730 Compact I O cable 3 28 ft 1 meter AD Left Bus Cap t 20D DL2 CL3 DriveLogix5730 Compact I O cable 3 28 ft 1 meter HII Right Bus Cap 8 IS DriveLogix 3 Meter RS 232 Programming Cable 1756 CP3 DriveLogix5720 Flex I O Cable 91 4 cm 36 in 4100 CCF3 Phase Control Assembly Cover Kit 20D CVR CA1 DriveLogix5720 Flex I O Cable w Assembly Cover 20D DL FLXO Requires Control Assembly Cover Kit 20D CVR CA1 Requires Expanded Cassette when used with Phase Il Control For use with Phase Il Control ONLY Refer to Publication 1769 SG001 for details and selection of Compact I O Phase II Drive Control Upgrade Kits Description PowerFlex 700S Phase II Control with Expanded Cassette 20D P2 CKEO PowerFlex 7008 DriveLogix5730 Phase Il Control with Expanded Cassette Isolation Transformers Motor Rating kW Hp 20D DL2 CKEO 240V 60 Hz Three Phase 240V Primary amp 240V Secondary Internal Dynamic Brake Resistor Kits These resistors have a limited duty cycle Refer to the PowerFlex Dynamic Braking Selection Guide to determine if an internal resistor will be sufficient for your application An external resistor may be required
78. consent by an authorized representative at Seller s headquarters Products sold or licensed hereunder are not intended to be used nor should they be used in any nuclear related application either as a Basic Component as defined under United States nuclear regulations or under similar nuclear laws and regulations of any other country or otherwise Allen Bradley Export Control Products and associated materials supplied or licensed hereunder may be subject to various export laws and regulations It is the responsibility of the exporter to comply with all such laws and regulations Notwithstanding any other provision herein to the contrary in the event that U S or local law requires export authorization for the export or re export of any Product or associated technology no delivery can be made until such export authorization is obtained regardless of any otherwise promised delivery date In the event that any required export authorization is denied Seller will be relieved of any further obligation relative to the sale and or license and delivery of the Product s subject to such denial without liability of any kind relative to Buyer or any other party Seller will not comply with boycott related requests except to the extent permitted by U S law and then only at Seller s discretion Disputes The parties will attempt in good faith promptly to resolve any dispute arising hereunder by negotiations between representatives of the p
79. drives are designed for high reliability ease of use and lower total cost of ownership Benefits of PowerFlex Medium Voltage Drives 1 Reduced costs Energy savings on fans pumps compressors Reduce maintenance costs on mechanical equipment Increase life of mechanical equipment 2 Improve process control Increase productivity Greater flexibility Environmental compliance 3 Starting large motors on weak power systems Eliminate voltage flicker Reduce inrush current Higher starting torque than reduced voltage starter For more information on PowerFlex 7000 Medium Voltage drives visit the Allen Bradley web site http www ab com drives powerflex Products 7000 htm 147 AC Adjustable Frequency Drives PowerFlex 7000 Medium Voltage Drives Notes 148 Allen Bradley AC Adjustable Frequency Drives Drives Software DriveTools SP Software Product Selection No of Application Cat No Licenses DriveExecutive 9303 4DTEO1ENE 1 DriveTools SP Suite includes DriveExecutive DriveObserver 9303 4DTSO1ENE 1 DriveTools SP Suite Upgrade from DriveExecutive 9303 4DTE2SO1ENE 1 includes DriveExecutive DriveObserver DriveTools SP is a family of software tools designed for Media Microsoft Windows NT v4 0 2000 XP operating systems DriveExecutive alone will also run on Windows 98 ME These applications provide a Simplified Programming interface for programming troubleshoot
80. is indicated by the marking on the product and not by statements in this catalog or any product literature FM Approval A limited number of Allen Bradley branded products have Factory Mutual Approval FM approves products for use in general as well as hazardous locations FM Class I Division 2 Hazardous Location Approval The product is approved by Factory Mutual Research Corporation for use in Class I Division 2 Group A B C and D or non hazardous locations only Although Rockwell Automation is only using the Class I Division 2 Group A B C D designation on its products it should be noted that this hazardous location classification is equivalent to the internationally defined Class I Zone 2 Group IIC area classification see IEC publication 60079 10 Therefore products labeled Class I Division 2 Group A B C D may be used in Class I Zone 2 Group IIC environments Actual FM Approval is indicated by the marking on the product and not by statements in this catalog or any product literature Certification for Marine and Off Shore Applications If a product or its packaging has a certification for marine and off shore applications it is listed in the Marine Certification Applications publication CIG 2 2 Also see www ab com certification 162 Many Allen Bradley branded products such as selected PLC 5 programmable controllers 1771 I O and Dataliner Message Displays have been certified for use in marine and offs
81. manipulate how data is graphed 150 DrivePanel32 This is the graphical implementation of the Human Interface Module HIM used with Allen Bradley AC and DC drive products It duplicates the programming and control functions available with the HIM and includes some special features only available with DrivePanel32 software DriveTrending32 This software provides a simple to use method for programming the internal drive trending functions supported by certain Allen Bradley drives as well as displaying the data stored within the internal drive trend buffers DriveBlockEditor32 This software uses a graphical format to create and monitor function block programs supported by certain Allen Bradley drives Pictorial flow diagrams allow you to easily follow the data flow within your uniquely designed drive application Powerful features such as Composite Blocks multiple level undo redo auto routing and user defined libraries allow you to create modify and maintain highly complex programs with ease Allen Bradley AC Adjustable Frequency Drives Drives Software Product Selection The DriveTools32 software has been packaged so that you can purchase either the entire Suite individual software applications within the family or a convenient Lite Bundle of the most popular applications Catalog numbers used for the DriveTools32 application are dependent on the specific options selected as listed in the followin
82. mount directly to the back surface of the drive and require no extra panel space Internal resistors are non destructive and do not require a resistor overheat external safety circuit PowerFlex 70 AC Drive Small Duty Internal DB Resistor Max Application Type 1 Application Type 2 Min DB Braking Braking Braking Normal Heavy Res Resistance Continuous Torque Torque Torque Duty Duty Ohms Power Max Energy of ND of ND of ND kW Hp kW Hp 10 Part Number Ohms 5 kW kJ Motor Motor Duty Cycle Motor Duty Cycle 200 240 Volt AC Input Drives 0 37 0 5 0 25 0 33 33 20AB DB1 A 62 0 048 8 3 307 100 25 9 150 17 3 0 75 1 0 0 55 0 75 33 20AB DB1 A 62 0 048 7 3 300 100 12 8 150 8 5 1 5 2 0 1 1 1 5 33 20AB DB1 B 62 0 028 0 8 160 100 3 7 150 2 5 2 2 3 0 1 5 2 0 33 20AB DB1 B 62 0 028 0 8 109 100 2 5 109 2 3 4 0 5 0 3 0 3 0 30 20AB DB1 C 62 0 040 0 8 60 60 3 3 N A N A 5 5 7 5 4 0 5 0 23 20AB DB1 D 22 0 036 0 9 117 100 1 3 117 1 1 7 5 10 5 5 7 5 23 20AB DB1 D 22 0 036 0 9 86 86 1 1 N A N A 400 480 Volt AC Input Drives 0 37 0 5 0 25 0 33 68 20AD DB1 A 115 0 048 8 3 320 100 25 9 150 17 3 0 75 1 0 0 55 0 75 68 20AD DB1 A 115 0 048 9 0 259 100 12 8 150 8 5 1 5 2 0 1 1 1 5 68 20AD DB1 A 115 0 048 2 4 243 100 6 4 150 4 3 2 2 3 0 1 5 2 0 68 20AD DB1 B 115 0 028
83. of the degrees of protection provided by different types of enclosures Performance Data Performance data given in this publication is provided only as a guide for the user in determining suitability and do not constitute a performance warranty of any kind Such data may represent the results of accelerated testing at elevated stress levels and the user is responsible for correlating the data to actual application requirements ALL WARRANTIES AS TO ACTUAL PERFORMANCE WHETHER EXPRESS OR IMPLIED ARE EXPRESSLY DISCLAIMED GENERAL TERMS AND CONDITIONS OF SALE These general terms and conditions of sale only apply to purchases of Allen Bradley and Rockwell Software branded products and related services made directly from Rockwell Automation Purchases made from appointed distributors or other independent resellers will be subject to terms and conditions of sale as may be separately established by each such distributor or reseller which will in no event be binding upon Rockwell Automation unless otherwise expressly agreed to Sales outside of North America as well as sales of other Rockwell Automation products and services may be subject to separate or supplemental terms and conditions of sale For further information please consult your nearest Rockwell Automation sales office General These general terms and conditions of sale along with any associated written specification quotation and or supplemental terms and conditions provide
84. order entry and can be ordered through the Passport order entry system Engineered Drives The Engineered Drives Program offers users the ability to create drive packages beyond the Standard Packaged Drives offering Options may or may not be defined within this publication Product can be ordered by Assembling a catalog string from the options listed in this publication Engineered options that are listed within this publication will be specified by the heading Engineered Drives Program Only and will have varied lead times Entering a custom quote request for additional options not listed A custom quote will require a Passport quote using SP SDB CUSTOM as the line item part number and entering a description of the base catalog string and custom options in the Competitive Summary For questions or help with a custom quote please contact the Engineered Drives Group at 262 512 8415 Allen Bradley 39 AC Adjustable Frequency Drives PowerFlex 400 Packaged Drives Programs Catalog Number Explanation To interpret the meaning of a catalog number match the values of the catalog number code in positions a b c etc with the tables labeled a b c etc below 13 4 5 6 8 9 10 23C D 038 A 1 a b C d e a Drive Code Type 23C PowerFlex 400 b Voltage Rating Code Ph X 208V ac 3 D 480V ac 3 el Rating 208V 60Hz Input Code Amps kW Hp Frame 012 12 2 2 3 0 C 017 16 8 3 7 5 0 C 024 2
85. power and I O wiring to the drive custom drive configuration tuning to meet application specific requirements and diagnosing troubleshooting problems that occur during a standalone drive start up ProtectionPlus can also extend an eligible product parts warranty and add a labor warranty For more information about ProtectionPlus Drive Services contact your local Rockwell Automation sales office or authorized distributor or visit http support rockwellautomation com SupportPrograms 154 assistance on the most effective ways to implement the control solution For more information please visit http www ab com support abdrives files supportplus pdf Description Cat No One Hour Design Consultation TS SP1HR Two Hour Design Consultation TS SP2HR On Site Power Analysis TS PASIOS Allen Bradley AC Adjustable Frequency Drives Important Safety and Product Information Contents Description Important User Information this page General Terms and Conditions of Sale page 156 Preventive Maintenance and Repair page 160 Product Compliance page 161 Specifying Enclosures page 163 Important User Information This guide has been developed as a quick reference tool to Allen Bradley industrial automation controls and factory assemblies It is not intended to replace factory user manuals or technical documentation supplied with Allen Bradley equipment Because of the variety of uses for the products desc
86. schematics Copy of Drawings that Shipped with the Job Diskette 1301 FINDISK Electronic Drawings 1301 FINDWG E Black 8 Whites 1301 FINDWG Vellums 1301 FINRV Mylar 1301 FINRM Test Report Drive Only 1301 TESTR Engineered Drives Program Only Approval Drawings 279 x 432 mm 11 x 17 in One set of schematics Manufacture Held Until Approved Prints are Received Diskette 1301 APPDISK Electronic Drawings 1301 APPDWG E Black amp Whites 1301 APPDWG Vellums 1301 APPRV As Commissioned Drawings 279 x 432 mm 11 x 17 in One set of schematics Provided after Field Changes are Returned to the Factory Black amp Whites 1301 COMDWG Certified Motor Dimension Drawing 1301 CERMTR Certified Transformer Dimension Drawing 1301 CERXFR Certified Line Reactor Dimension Drawing 1301 CERLR Disk Copy of Final As Shipped Schematics Autocad 2000 1301 DISK Witness Test User Viewing of Rockwell Automation Standard Test Procedures 1301 WT Includes viewing Rockwell Automation standard test only Any special requirements must be reviewed by Rockwell Automation for acceptance and possible price changes 70 Allen Bradley AC Adjustable Frequency Drives PowerFlex 70 Packaged Drives Programs
87. service mark may be placed on a product its literature and or advertising only after it has successfully passed conformance testing at an official independent test lab of the Open DeviceNet Vendor Association EtherNet IP Conformance The Conformance Tested Service Mark is an ODVA controlled logo protected by law the authorized use of which indicates that a product has passed conformance testing at an official ODVA Test Service Provider TSP The EtherNet IP conformance tested service mark may be placed on a product its literature and or advertising only after it has successfully passed conformance testing at an official independent test lab of the Open DeviceNet Vendor Association Type Designed to For Indoor Use Outdoor Use Indoor or Outdoor For a Degree of Protection Against Meet Tests No 1 12 13 3R 3 4 4X 6P Incidental contact with enclosed equipment 6 2 Y Y Y Y Y Y Y Y Falling dirt 6 2 Y Y Y Y Y Y Y Y Rust 6 8 Y Y Y Y Y Y Y Y Circulating dust lint fibers and flyings 6 5 1 2 2 Y Y Y Y Y Y Windblown dust 6 5 1 1 2 Y Y Y Y Falling liquids and light splashing 6 3 2 2 Y Y Y Y Y Y Rain Test evaluated per 6 4 2 1 6 4 2 1 Y Y Y Y Y Rain Test evaluated per 6 4 2 2 6 4 2 2 Y Y Y Y Snow and sleet 6 6 2 2 Y Y Y Y Y Hosedown and splashing water 6 7 Y Y Y Occasional prolonged submersion 6 11 2 Y Oil and coolant seepage 6 3 2 2 Y Y Oil or coolant spraying and splashing 6 12 Y Co
88. software tools designed for Microsoft Windows 95 Windows 98 and Windows NT 4 0 operating systems These applications provide you with an intuitive means for programming troubleshooting and maintaining your legacy Allen Bradley AC and DC drive products Easy to use menus dialogs and graphic displays help you to quickly start up your Allen Bradley drive product Powerful diagnostic features simplify diagnosing drive as well as system problems DriveManager32 This software is the primary product in the DriveTools32 family It provides you with all the easy to use tools you ll need to create and edit online or offline drive data tables which are used to configure the drive for your application Whether it s your first Allen Bradley drive or you manage a plant full the online product help easy to use search capabilities graphic analog metering and a logic probe tool help to make drive start ups simple File compare utilities help to assure drive data integrity and extensive documentation options keep your maintenance records simple and complete DriveMonitor32 An optional tool within the DriveTools32 family provides you with an advanced method of graphically monitoring drive data You can also chart controller data points when connected to a network such as Data Highway Plus or ControlNet You can easily display live data values in a graphic format The display options in this software tool allow you to easily
89. warranty if any extended by the original manufacturer or vendor directly or indirectly to Buyer Seller does not warrant the compatibility of its Products with the goods of other manufacturers or Buyer s application except to the extent expressly represented in Seller s published specifications or written quotation g Recyclable Materials In keeping with environmental policies and practices Seller reserves the right to utilize in its product manufacturing repair and remanufacturing processes certain recyclable materials e g fasteners plastics and the like or remanufactured parts equivalent to new in performance or parts which may have been subject to incidental use However such utilization will not affect any provided Product warranty or published reliability statistics h Remedies Remedies under the above warranties will be limited at Seller s option to the replacement repair re performance or modification of or issuance of a credit for the purchase price of the Products involved and where applicable Allen Bradley only after the return of such Products pursuant to Seller s instructions Replacement Products may be new remanufactured refurbished or reconditioned at Seller s discretion Buyer requested on site warranty service consisting of time travel and expenses related to such services will be at Buyer s expense The foregoing will be the exclusive remedies for any breach of warranty or breach o
90. 0 16 10 16 A54 AO A58 A58 A58 A58 A16 A26 16 24 10 16 A54 AO A58 A58 A60 A60 A16 A26 18 30 18 30 A54 AO A58 A58 A60 A60 A16 600V ac Three Phase Drives A26 0 6 1 0 0 6 1 0 A54 N A A58 A58 A58 A58 A16 A26 1 6 2 4 1 0 1 6 A54 N A A58 A58 A58 A58 A16 A26 2 4 4 0 1 6 2 4 A54 N A A58 A58 A58 A58 A16 A26 2 4 4 0 2 4 4 0 A54 N A A58 A58 A58 A58 A16 A26 6 0 10 4 0 6 0 A54 N A A58 A58 A58 A58 A16 A26 6 0 10 6 0 10 A54 N A A58 A58 A58 A58 A16 A26 10 16 6 0 10 A54 N A A58 A58 A58 A58 A16 A26 16 24 10 16 A54 N A A58 A58 A60 A60 A16 A26 16 24 16 24 A54 N A A58 A58 A60 A60 A16 Option JF is required Cannot be used with BM1 BM2 or BA Cannot be used with KM BM1 cannot be used with BM2 Bypass duty cycle must match drive duty cycle This option does not provide 115V AC control interface to the drive or MH option Applies to NEMA Type 1 drives only Option includes Drive Off Bypass selector switch Requires CF option or customer supplied 115V Allen Bradley 67 AC Adjustable Frequency Drives PowerFlex 70 Packaged Drives Programs Factory Installed Options Human Interface Modules Cat Code HO No HIM Blank Cover Cat Code H1 LED Digital Speed Cat Code H4 LCD Analog Speed Cat Code H5 LCD Programmer Only Human Interface Modules LED LCD Must Choose One Cat Code H2 LCD Digital Speed Cat Code H3 LCD Full Numeric Ca
91. 0 052 52 50 J 650V de 5 N 072 72 37 062 62 60 E 540V de 3 E Y 085 85 45 077 77 75 R 650V dc 7 Y 105 105 55 099 99 100 3 Frames 5 amp 6 Only 140 140 75 125 125 125 170 170 90 144 144 150 260 260 132 c1 ND Rating c3 208 240V 60 Hz Input ND Rating c5 Code 208V 240V Hp 480V 60 Hz Input ND Rating Amps Amps a aa _ Code Amps Hp 690V 50 Hz Input 2P2 25 2 2 0 5 z pe LL IR UEM 1P1 1 1 0 5 ode Amps kW 4P2 4 8 4 2 1 0 2P1 24 1 0 052 52 45 6P8 78 6 8 2 0 3P4 3 4 2 0 050 60 55 9P6 11 9 6 3 0 5PO 5 0 3 0 082 82 75 015 17 5 15 8 5 0 8P0 8 0 5 0 098 98 90 022 25 3 22 75 om T 25 119 119 110 028 32 2 28 10 m a 35 142 142 132 042 48 3 42 15 E S S I me 052 56 52 20 ee 22 de 070 782 70 25 ver zi zu 080 92 80 30 un 34 29 104 120 104 40 030 40 30 130 130 130 50 052 52 40 154 177 154 60 065 65 50 192 221 192 75 ory LE 60 260 260 260 100 ES E 18 125 125 100 156 156 125 180 180 150 248 248 200 76 Allen Bradley AC Adjustable Frequency Drives PowerFlex 700 d g k Enclosure Brake 1 0 Code Enclosure Code w Brake IGBT Code Control 1 0 Volts A IP21 NEMA Type 1 Y Yes A Std 24V dc ac Flange Mount N No B Std 115V ac F dide ion a Brake IGBT is standard on Frames 0 3 and C Vector 24V de ack Heatsink e yp optional on Frames 4 6 D Vector 115V ac G Stand Alone Wall Mount IP54 NEMA Type 12 N Std None Vector Control Option utilizes DPI Only
92. 0 1 1 1 5 d c2 Enclosure Rating Code Enclosure 200 240V Single Phase Input No Brake N Panel Mount aay NEMA Typ aa Amps kW E Flange Mount IP 20 NEMA Type 1P4 1 4 0 2 0 25 Open 2P1 2 1 0 4 0 5 Replacement Plate Drive IP 20 3P6 3 6 0 75 1 0 NEMA Type Open H 6P8 6 8 1 5 2 0 Contact factory for ordering 9P6 9 6 2 2 8 0 information c3 id Rating HIM 200 240V Single Phase Input Code ie Module Code Amps kW Hp 1 Fixed Keypad IPS 15 0 2 0 25 2P3 2 3 0 4 0 5 4P5 4 5 0 75 1 0 8PO 8 0 1 5 2 0 8 Allen Bradley Product Selection 120V ac Single Phase Drives 50 60 Hz No Filter AC Adjustable Frequency Drives PowerFlex 4 Drive Ratings IP20 NEMA Type Open IP20 Flange Mount Output Current kW Hp A Cat No Frame Size Cat No 0 2 0 25 1 5 22A V1P5N104 A 22A V1P5F104 0 4 0 5 2 3 22A V2P3N104 A 22A V2P3F104 0 75 1 0 4 5 22A V4P5N104 B 22A V4P5F104 14 1 5 6 0 22A V6PON104 B 22A V6POF104 Meets 1P40 54 65 NEMA 1 12 4 4X when installed in an enclosure of like rating 240V ac Single Phase Drives 50 60 Hz No Brake Drive Ratings IP20 NEMA Type Open IP20 Flange Mountx Output Current kw Hp A Cat No Frame Size Cat No With Integral S Type EMC Filter 0 2 0 25 1 4 22A A1P4N113 A 0 4 0 5 2 1 22A A2P1N113 A 0 75 1 0 3 6 22A A3P6N113 A 1 5 2 0 6 8 22A A6P8N113 B 2 2 3 0 9 6 22A A9P6N113 B No Filter 0 2 0 25 1 4 2
93. 0 1321 3R130 B 1321 3RA130 B 1321 3R130 B 1321 3RA130 B 20DD140 Heavy Duty 75 1321 3R100 B 1321 3RA100 B 1321 3R100 B 1321 3RA100 B 20DD140 Normal Duty 100 1321 3R130 B 1321 3RA130 B 1321 3R130 B 1321 3RA130 B 20DD156 Heavy Duty 100 1321 3R130 B 1321 3RA130 B 1321 3R130 B 1321 3RA130 B 20DD156 Normal Duty 125 1321 3R160 B 1321 3RA160 B 1321 3R160 B 1321 3RA160 B 20DD180 Heavy Duty 125 1321 3R160 B 1321 3RA160 B 1321 3R160 B 1321 3RA160 B 20DD180 Normal Duty 150 1321 3R200 B 1321 3RA200 B 1321 3R200 C 1321 3RA200 C 20DD248 Heavy Duty 150 1321 3R200 B 1321 3RA200 B 1321 3R200 C 1321 3RA200 C 20DD248 Normal Duty 200 1321 3RB250 B 1321 3RAB250 B 1321 3RB250 B 1321 3RAB250 B 20DD261 Heavy Duty 150 1321 3R200 B 1321 3RA200 B 1321 3R200 B 1321 3RA200 B 20DD261 Normal Duty 200 1321 3RB250 B 1321 3RAB250 B 1321 3RB250 B 1321 3RAB250 B 20DD300 Heavy Duty 200 1321 3RB250 B 1321 3RAB250 B 1321 3RB250 B 1321 3RAB250 B Input line reactors were sized based on the NEC fundamental motor amps Output line reactors were sized based on the VFD rated output currents Allen Bradley 139 AC Adjustable Frequency Drives PowerFlex 700S Input and Output Line Reactors 480V 60 Hz Three Phase 5 Impedance Input Line Reactor Output Line Reactor IPOO Open Style IP11 NEMA Type 1 IPOO Open Style 1P11 NEMA Type 1
94. 0 2 0 3 0 20 11 3 1321 3R2 B 15 2 0 4 0 6 0 6 5 20 1321 3R4 C 2 2 3 0 4 0 6 0 6 5 20 1321 3R4 B 4 0 5 0 8 0 12 5 0 25 3 1321 3R8 C 5 5 7 5 12 18 2 5 31 1321 3R12 B 7 5 10 12 18 2 5 31 1321 3R12 B 11 15 18 27 1 5 43 1321 3R18 B Catalog numbers listed are for 3 impedance open style units NEMA Type 1 and 5 impedance reactor types are also available Refer to publication 1321 TDOO1 Allen Bradley 19 AC Adjustable Frequency Drives PowerFlex 40 EMC Filters Drive Ratings S Type Filter L Type Filter Input Voltage kW Hp Cat No Cat No 0 4 0 5 E 22 RF018 BL nem 0 75 10 22 RFO18 BL 1 1 1 5 22 RF018 BL 0 4 0 5 22 RF018 BL 240V 50 60 Hz 0 75 1 0 ES 22 RF018 BL 1 Phase 1 5 2 0 22 RF018 BL 2 2 3 0 22 RF025 CL 0 4 0 5 22 RF021 BS 22 RF021 BL 0 75 1 0 22 RF021 BS 22 RF021 BL 1 5 2 0 22 RF021 BS 22 RF021 BL di 2 2 3 0 22 RF021 BS 22 RF021 BL 3 7 5 0 22 RF021 BS 22 RF021 BL 5 5 7 5 22 RF034 CS 22 RF034 CL 7 5 10 22 RF034 CS 22 RF034 CL 0 4 0 5 22 RF012 BS 22 RF012 BL 0 75 1 0 22 RF012 BS 22 RF012 BL 1 5 2 0 22 RF012 BS 22 RF012 BL 480V 50 60 Hz 2 2 3 0 22 RF012 BS 22 RF012 BL 3 Phase 4 0 5 0 22 RF012 BS 22 RF012 BL 5 5 7 5 22 RF018 CS 22 RF018 CL 7 5 10 22 RF018 CS 22 RF018 CL 11 15 22 RF026 CS 22 RF026 CL 0 75 1 0 22 RF8P0 BL 1 5 2 0 22 RF8P0 BL 2 2 3 0 22 RF8P0 BL 2 4 0 5 0 22 RFSPO BL 5 5 7 5 22 RF015
95. 0 B 1321 3RAB250 B 1321 3RB250 B 1321 3RAB250 B Input line reactors were sized based on the NEC fundamental motor amps Output line reactors were sized based on the VFD rated output currents 138 Allen Bradley AC Adjustable Frequency Drives PowerFlex 700S Input and Output Line Reactors 480V 60 Hz Three Phase 3 Impedance Input Line Reactor Output Line Reactor Drive IPOO Open Style IP11 NEMA Type 1 IPOO Open Style IP11 NEMA Type 1 Cat No Duty Hp Cat No Cat No Cat No Cat No 20DD1P1 Heavy Duty 0 33 1321 3R1 C 1321 3RA1 C 1321 3R2 B 1321 3RA2 B 20DD1P1 Normal Duty 0 5 1321 3R1 C 1321 3RA1 C 1321 3R2 B 1321 3RA2 B 20DD2P1 Heavy Duty 0 75 1321 3R2 A 1321 3RA2 A 1321 3R2 A 1321 3RA2 A 20DD2P1 Normal Duty 1 1321 3R2 A 1321 3RA2 A 1321 3R2 A 1321 3RA2 A 20DD3P4 Heavy Duty 15 1321 3R4 C 1321 3RA4 C 1321 3R4 B 1321 3RA4 B 20DD3P4 Normal Duty 2 1321 3R4 B 1321 3RA4 B 1321 3R4 B 1321 3RA4 B 20DD5P0 Heavy Duty 2 1321 3R4 B 1321 3RA4 B 1321 3R8 C 1321 3RA8 C 20DD5P0 Normal Duty 3 1321 3R8 C 1321 3RA8 C 1321 3R8 C 1321 3RA8 C 20DD8P0 Heavy Duty 3 1321 3R8 C 1321 3RA8 C 1321 3R8 B 1321 3RA8 B 20DD8P0 Normal Duty 5 1321 3R8 B 1321 3RA8 B 1321 3R8 B 1321 3RA8 B 20DD011 Heavy Duty 5 1321 3R8 B 1321 3RA8 B 1321 3R12 B 1321 3RA12 B 20DD011 Normal Duty TS 1321 3R12 B 1321 3
96. 042 Heavy Duty 10 1321 3R35 B 1321 3RA35 B 1321 3R45 B 1321 3RA45 B 20AB042 Normal Duty 15 1321 3R45 B 1321 3RA45 B 1321 3R45 B 1321 3RA45 B 20AB054 Heavy Duty 15 1321 3R45 B 1321 3RA45 B 1321 3R55 B 1321 3RA55 B 20AB054 Normal Duty 20 1321 3R55 B 1321 3RA55 B 1321 3R55 B 1321 3RA55 B 20AB070 Heavy Duty 20 1321 3R55 B 1321 3RA55 B 1321 3R80 B 1321 3RA80 B 20AB070 Normal Duty 25 1321 3R80 B 1321 3RA80 B 1321 3R80 B 1321 3RA80 B Input line reactors were sized based on the NEC fundamental motor amps Output line reactors were sized based on the VFD rated output currents 56 Allen Bradley AC Adjustable Frequency Drives PowerFlex 70 Input and Output Line Reactors 480V 60 Hz Three Phase 3 Impedance Input Line Reactor Output Line Reactor IPOO Open Style IP11 NEMA Type 1 IPOO Open Style IP11 NEMA Type 1 Drive Cat No Duty Hp Cat No Cat No Cat No Cat No 20AD1P1 Heavy Duty 0 33 1321 3R1 C 1321 3RA1 C 1321 3R2 B 1321 3RA2 B 20AD1P1 Normal Duty 0 5 1321 3R1 C 1321 3RA1 C 1321 3R2 B 1321 3RA2 B 20AD2P1 Heavy Duty 0 75 1321 3R2 A 1321 3RA2 A 1321 3R2 A 1321 3RA2 A 20AD2P1 Normal Duty 1 0 1321 3R2 A 1321 3RA2 A 1321 3R2 A 1321 3RA2 A 20AD3P4 Heavy Duty 15 1321 3R4 C 1321 3RA4 C 1321 3R4 B 1321 3RA4 B 20AD3P4 Normal Duty 2 0 1321 3R4 B 1321 3RA4 B 1321 3R4 B 1321 3RA4 B 20AD5PO Heavy Duty 2 0 1
97. 1 N Open IPOO x 3 Frames 9 amp up Only e HIM Code Operator Interface 0 Blank Cover 2 Digital LCD 3 Full Numeric LCD 5 Prog Only LCD C Full Numeric LCD Door Mount Frames 10 amp up only 132 h Brake Resistor Code w Resistor Y Yes N No Not available for Frame 3 drives or larger i Emission Code CE Filter CM Choke A Yes Yes B 3 Yes No NS No No Frames 1 6 Only 38 Frames 9 amp up Only 8 For use on ungrounded distribution systems Frame 9 drives only DriveLogix EtherNet IP k Control Options Code Cassette I Feedback Code Option N None A Resolver B Stegman Hi Resolution Encoder C Multi Device Interface m Additional Config Code Description N Phase Control A Phase I DriveLogix5720 B Phase I DriveLogix5720 w Expanded Memory Allen Bradley AC Adjustable Frequency Drives PowerFlex 700S Phase I Product Selection 208 240V ac Three Phase Drives 240V ac Input 208V ac Input IP20 NEMA Type 1 Output Amps Normal Heavy Duty Output Amps Normal Heavy Duty Cat No Frame Cont 1 Min 3 Sec Duty Hp Hp Cont 1 Min 3 Sec Duty kW kw 20D Size 4 2 4 8 6 4 1 0 0 75 4 8 5 6 7 0 0 75 0 37 B4P2A0EYNANNNN 1 6 8 9 0 12 2 0 1 5 7 8 10 4 13 8 1 5 0 75 B6P8AOEYNANNNN 1 9 6 10 6 14 4 3 0 2 0 11 12 1 17 2 2 1 5 B9P6AOEYNANNNN
98. 1 Wall Machine Mount IP66 C NEMA Type 4X 12 for indoor use only Flange Mount Front Chassis F IP 20 NEMA Type 1 Rear Heatsink IP66 UL Type 4x 12 for indoor outdoor use G Wall Machine Mount IP54 NEMA Type 12 e HIM Code Interface Module 0 Blank Cover 2 Digital LCD 3 Full Numeric LCD 5 Prog Only LCD IP66 NEMA Type 4X 12 Enclosure Code C is available only with HIM Codes 0 3 or 5 Allen Bradley AC Adjustable Frequency Drives PowerFlex 70 f Documentation English User Manual and Multi Language Quick Start N No Manual g Brake IGBT Code w Brake IGBT M Yes h Internal Brake Resistor Code w Resistor M Yes N No Allen Bradley i Emission Class Filtered A A 8 B Frames Optional C D amp E Frames Standard Not Filtered N A amp B Frames Optional C D amp E Frames 600V Frames A through D available only without filter Cat Code N 600V Frame E available only with filter Cat Code A Increases size to Frame B J Comm Slot Code Version C ControlNet Coax D DeviceNet E EtherNet IP H RS485 HVAC R RIO S RS485 DF1 N None k Control amp I O Code Safe Off N Standard N A C Enhanced No G Enhanced Yes Not available as factory installed option for 600V ratings I Feedback Code Feedback N N A 0 None 1 5V 12V Encoder 47 AC Adjustable Frequency Drives PowerFlex 70 Stock
99. 1 3R2 D 1321 3RA2 D 20AB2P2 Normal Duty 0 5 1321 3R2 D 1321 3RA2 D 1321 3R2 D 1321 3RA2 D 20AB4P2 Heavy Duty 0 75 1321 3R4 A 1321 3RA4 A 1321 3R4 A 1321 3RA4 A 20AB4P2 Normal Duty 1 0 1321 3R4 A 1321 3RA4 A 1321 3R4 A 1321 3RA4 A 20AB6P8 Heavy Duty 1 5 1321 3R8 B 1321 3RA8 B 1321 3R8 A 1321 3RA8 A 20AB6P8 Normal Duty 2 0 1321 3R8 A 1321 3RA8 A 1321 3R8 A 1321 3RA8 A 20AB9P6 Heavy Duty 2 0 1321 3R8 A 1321 3RA8 A 1321 3R12 A 1321 3RA12 A 20AB9P6 Normal Duty 3 0 1321 3R12 A 1321 3RA12 A 1321 3R12 A 1321 3RA12 A 20AB015 Heavy Duty 3 0 1321 3R12 A 1321 3RA12 A 1321 3R18 A 1321 3RA18 A 20AB015 Normal Duty 5 0 1321 3R18 A 1321 3RA18 A 1321 3R18 A 1321 3RA18 A 20AB022 Heavy Duty 5 0 1321 3R18 A 1321 3RA18 A 1321 3R25 A 1321 3RA25 A 20AB022 Normal Duty 1 5 1321 3R25 A 1321 3RA25 A 1321 3R25 A 1321 3RA25 A 20AB028 Heavy Duty 7 5 1321 3R25 A 1321 3RA25 A 1321 3R35 A 1321 3RA35 A 20AB028 Normal Duty 10 1321 3R35 A 1321 3RA35 A 1321 3R35 A 1321 3RA35 A 20AB042 Heavy Duty 10 1321 3R35 A 1321 3RA35 A 1321 3R45 A 1321 3RA45 A 20AB042 Normal Duty 15 1321 3R45 A 1321 3RA45 A 1321 3R45 A 1321 3RA45 A 20AB054 Heavy Duty 15 1321 3R45 A 1321 3RA45 A 1321 3R55 A 1321 3RA55 A 20AB054 Normal Duty 20 1321 3R55 A 1321 3RA55 A 1321 3R55 A 1321 3RA55 A 20AB070 Heavy Duty 20 1321 3R55 A 1321 3RA55 A 1321 3R80 A 1321 3RA80 A 20AB070 Normal Duty 25 1321 3R80 A 1321 3RA80 A 1321 3R80 A 1321 3RA80 A Input line reactors were sized based on the NEC fu
100. 1 3R55 C 1321 3RA55 C 1321 3R55 C 1321 3RA55 C Input line reactors were sized based on the NEC fundamental motor amps Output line reactors were sized based on the VFD rated output currents t Reactors sized at 496 impedance 60 Allen Bradley Isolation Transformers NEMA 3R Standalone Motor Rating kW Hp 240V 60 Hz Three Phase 230V Primary 8 230V Secondary AC Adjustable Frequency Drives PowerFlex 70 480V 60 Hz Three Phase 460V Primary 8 460V Secondary 600V 60 Hz Three Phase 575V Primary amp 575V Secondary IP32 NEMA Type 3R IP32 NEMA Type 3R IP32 NEMA Type 3R Cat No Cat No Cat No 0 25 0 33 1321 3TW005 AA 1321 3TW005 BB 0 37 0 5 1321 3TW005 AA 1321 3TW005 BB 1321 3TW005 CC 0 55 0 75 1321 3TW005 AA 1321 3TW005 BB 0 75 1 0 1321 3TW005 AA 1321 3TW005 BB 1321 3TW005 CC 14 15 1321 3TW005 AA 1321 3TW005 BB 1 5 2 0 1321 3TW005 AA 1321 3TW005 BB 1321 3TW005 CC 2 2 3 0 1321 3TW005 AA 1321 3TW005 BB 1321 3TW005 CC 4 0 5 0 1321 3TW007 AA 1321 3TW007 BB 1321 3TW007 CC 5 5 7 5 1321 3TW011 AA 1321 3TW011 BB 1321 3TW011 CC 7 5 10 1321 3TW014 AA 1321 3TW014 BB 1321 3TW014 CC 11 15 1321 3TW020 AA 1321 3TW020 BB 1321 3TW020 CC 15 20 1321 3TW027 AA 1321 3TW027 BB 1321 3TW027 CC 18 5 25 1321 3TW034 AA 1321 3TW034 BB 1321 3TW034 CC 22 30 1321 3TW040 BB 1321 3TW040 CC 30 40
101. 110 90 N 20BJ180A0ANNANCO 6 180 156 198 234 270 312 150 125 205 170 220 255 289 313 110 90 Y 20BR180A0ANNANCO 6 248 180 gt 273 270 372 360 200 150 260 205 gt 286 308 390 410 132 110 N 20BJ248A0ANNANCO 6 248 180 gt 273 270 372 360 200 150 260 205 gt 286 308 390 410 132 110 Y 20BR248A0ANNANCO 6 Catalog number corresponds to output amps in these columns Drive must be programmed to lower voltage to obtain higher currents shown at right Frame 5 and 6 drives have dual current ratings one for normal duty applications and one for heavy duty applications in parenthesis The drive may be operated at either rating Rating is limited to 40 C surrounding air Allen Bradley 79 AC Adjustable Frequency Drives PowerFlex 700 810V dc Input Drives 810V dc Input 690V dc Input IP20 NEMA Type 1 Output Amps Normal Heavy Output Amps Normal Heavy DC Pre Frame Cont 1 Min 3 Sec Duty Hp Duty Hp Cont 1 Min 3Sec Duty kW Duty kW charge Cat No Size 99 77 109 116 126 138 100 75 98 82 108 123 127 140 90 75 Y 20BTO99A0ANNANCO 5 144 125 1158 188 216 250 150 125 142 119 156 179 213 238 132 110 Y 20BT144A0ANNANCO 6 Catalog number corresponds to output amps in these columns Drive must be programmed to lower voltage to obtain higher currents shown at right
102. 12 Position d F 380 480V ac Three Phase Drives 480V ac Input 380 400V ac Input Output Amps Normal Heavy Output Amps Normal Heavy Cat No Frame Cont 1 Min 3 Sec Duty Hp Duty Hp Cont 1 Min 3 Sec Duty kW Duty kW 20D Size 96 77 106 116 144 154 75 60 105 85 116 128 1158 170 55 45 DO96FOENNANANE 5 125 96 138 144 163 168 100 15 125 96 138 144 1163 168 55 45 D125FOENNANANE 5 156 125 172 188 233 250 125 100 170 140 187 210 255 280 90 TS D156FOENNANANE 6 180 156 198 234 270 312 150 125 205 170 220 255 289 313 110 90 D180FOENNANANE 6 PG 180 273 270 1372 360 200 150 260 205 gt 286 308 390 410 132 110 D248FOENNANANE 6 Catalog number corresponds to output amps in these columns Drive must be programmed to lower voltage to obtain higher currents shown at right Frame 5 and 6 drives have dual current ratings one for normal duty applications and one for heavy duty applications in parenthesis The drive may be operated at either rating Rating is limited to 45 C surrounding air Rating is limited to 40 C surrounding air Phase I PowerFlex 700S Phase I Control 130 Phase Features Digital Inputs 24V dc Inputs Programmable Enable Inputs Digital Outputs Relay 24V de Analog Inputs Analog Outputs Encoder Inputs Open Coll
103. 125A0AYNANAOBN 90 125 156 172 233 6 21WD156A0AYNANAOBN 110 150 180 198 270 6 21WD180A0AYNANAOBN 460V ac 3 Contactor Basic Bypass with Disconnect Package Code C NEMA Type 1 without HIM amp Drive Ratings Communication Adapter Output Current kW Hp Cont 1 Min 3 Sec Frame Size Cat No 0 75 1 0 2 1 24 3 2 B 21VD2P1A0AYNANCOCN 1 5 2 0 3 4 4 5 6 0 B 21VD3P4A0AYNANCOCN 2 2 3 0 5 0 5 5 7 5 B 21VD5POAOAYNANCOCN 4 0 5 0 8 0 8 8 12 B 21VD8POAOAYNANCOCN 5 5 7 5 11 12 1 16 5 C 21VD011A0AYNANCOCN 7 5 10 14 16 5 22 C 21VD014A0AYNANCOCN 11 15 22 24 2 33 D 21VD022A0AYNANCOCN 15 20 27 33 44 D 21VD027A0AYNANCOCN 18 5 25 34 40 5 54 D 21VD034A0AYNANCOCN 22 30 40 51 68 D 21VD040A0AYNANCOCN 30 40 52 60 80 E 21VD052A0AYNANCOCN 37 50 65 78 104 E 21VD065A0AYNANCOCN 45 60 77 85 116 4 21WD077A0AYNANAOCN 55 75 96 106 144 5 21WD096A0AYNANAOCN 75 100 125 138 163 5 21WD125A0AYNANAOCN 108 Allen Bradley AC Adjustable Frequency Drives PowerFlex Drive Packages for Fan amp Pump Applications 600V ac Main Input Disconnect Package Code A Drive Ratings NEMA Type 1 without HIM 8 Communication Adapter Output Current kW Hp Cont 1 Min 3 Sec Frame Size Cat No 2 2 3 0 3 9 4 3 5 8 B 21VESP9AOAYNNNCOAN 4 0 5 0 6 1 6 7 9 1 B 21VE6P1A0AYNNNCOAN 5 5 7 5 9 0 9 9
104. 12A103NNAANN 7 5 10 14 C 23C D017A103NNAANN 11 15 21 C 23C D022A103NNAANN 15 20 27 C 23C D030A103NNAANN 18 5 25 34 D 23C D038A103NNAANN 22 30 40 D 23C D045A103NNAANN 30 40 52 D 23C D060A103NNAANN 37 50 65 E 23C D072A103NNAANN 45 60 77 E 23C D088A103NNAANN 55 75 96 E 23C D105A103NNAANN 75 100 124 E 23C D142A103NNAANN 90 125 156 F 23C D170A103NNAANN 110 150 180 F 23C D208A103NNAANN Allen Bradley 41 AC Adjustable Frequency Drives PowerFlex 400 Packaged Drives Programs 460V ac 3 Contactor Full Feature Bypass with Disconnect Drive Ratings Single Motor Output Current 40 C kW Hp A Frame Size Cat No 2 2 3 0 4 8 C 23C D6POA103NNBANN 4 0 5 0 7 6 C 23C D010A103NNBANN 5 5 7 5 11 C 23C D012A103NNBANN 7 5 10 14 C 23C D017A103NNBANN 11 15 21 C 23C D022A103NNBANN 15 20 27 C 23C D030A103NNBANN 18 5 25 34 D 23C D038A103NNBANN 22 30 40 D 23C D045A103NNBANN 30 40 52 D 23C D060A103NNBANN 37 50 65 E 23C D072A103NNBANN 45 60 77 E 23C D088A103NNBANN 55 75 96 E 23C D105A103NNBANN 75 100 124 E 23C D142A103NNBANN 90 125 156 F 23C D170A103NNBANN 110 150 180 F 23C D208A103NNBANN 460V ac 3 Contactor Basic Bypass with Disconnect Drive Ratings Single Motor Output Current 40 C kW Hp A Frame Size Cat No 2 2 3 0 4 8 C 23C D6P0A103NNCANN 4 0 5 0 7 6 C 23C D010A103NNCANN 5 5 7 5 11 C 23C D012A103NNCANN 4 5 10 14 C 23C D017A103
105. 13 5 C 21VEQPOAOAYNNNCOAN 7 5 10 11 13 5 18 C 21VE011A0AYNNNCOAN 11 15 17 18 7 25 5 D 21VE017A0AYNNNCOAN 15 20 22 25 5 34 D 21VE022A0AYNNNCOAN 18 5 25 27 33 44 D 21VE027A0AYNNNCOAN 22 30 32 40 5 54 D 21VE032A0AYNNNCOAN 30 40 41 48 64 E 21VE041A0AYNNNCOAN 37 50 52 61 5 82 E 21VE052A0AYNNNCOAN 45 60 62 78 104 4 21WE062A0AYNANAOAN 55 75 77 85 116 5 21WE077A0AYNANAOAN 75 100 99 109 126 5 21WE099A0AYNANAOAN 90 125 125 138 188 6 21WE125A0AYNANAOAN 110 150 144 158 216 6 21WE144A0AYNANAOAN 600V ac 3 Contactor Full Feature Bypass with Disconnect Package Code B NEMA Type 1 without HIM amp Drive Ratings Communication Adapter Output Current kW Hp Cont 1 Min 3 Sec Frame Size Cat No 2 2 3 0 3 9 4 3 5 8 B 21VE3P9AOAYNNNCOBN 4 0 5 0 6 1 6 7 9 1 B 21VE6P1A0AYNNNCOBN 5 5 7 5 9 0 9 9 13 5 G 21VEQPOAOAYNNNCOBN 75 10 11 13 5 18 C 21VE011A0AYNNNCOBN 11 15 17 18 7 25 5 D 21VE017A0AYNNNCOBN 15 20 22 25 5 34 D 21VE022A0AYNNNCOBN 18 5 25 27 33 44 D 21VE027A0AYNNNCOBN 22 30 32 40 5 54 D 21VE032A0AYNNNCOBN 30 40 41 48 64 E 21VE041A0AYNNNCOBN 37 50 52 61 5 82 E 21VE052A0AYNNNCOBN 45 60 62 78 104 4 21WE062A0AYNANCOBN 55 75 77 85 116 5 21WE077A0AYNANCOBN 75 100 99 109 126 5 21WE099A0AYNANAOBN 90 125 125 138 188 6 21WE125A0AYNANAOBN 110 150 144 158 216 6 21WE144A0AYNANAOBN Allen Bradley 109 AC Adjustable Frequency Drives PowerFlex Drive Packages for Fan amp Pump Applications Factory Installed Options Human Interface Module
106. 1321 3RA4 C 1321 3R8 C 1321 3RA8 C 20DE6P1 Normal Duty 5 1321 3R8 C 1321 3RA8 C 1321 3R8 C 1321 3RA8 C 20DE9P0 Heavy Duty 5 1321 3R8 C 1321 3RA8 C 1321 3R12 C 1321 3RA12 C 20DE9P0 Normal Duty 7 5 1321 3R12 C 1321 3RA12 C 1321 3R12 C 1321 3RA12 C 20DE011 Heavy Duty 7 5 1321 3R12 C 1321 3RA12 C 1321 3R12 B 1321 3RA12 B 20DE011 Normal Duty 10 1321 3R12 B 1321 3RA12 B 1321 3R12 B 1321 3RA12 B 20DE017 Heavy Duty 10 1321 3R12 B 1321 3RA12 B 1321 3R18 B 1321 3RA18 B 20DE017 Normal Duty 15 1321 3R18 B 1321 3RA18 B 1321 3R18 B 1321 3RA18 B 20DE022 Heavy Duty 15 1321 3R18 B 1321 3RA18 B 1321 3R25 B 1321 3RA25 B 20DE022 Normal Duty 20 1321 3R25 B 1321 3RA25 B 1321 3R25 B 1321 3RA25 B 20DE027 Heavy Duty 20 1321 3R25 B 1321 3RA25 B 1321 3R35 C 1321 3RA35 C 20DE027 Normal Duty 25 1321 3R35 C 1321 3RA35 C 1321 3R35 C 1321 3RA35 C 20DE032 Heavy Duty 25 1321 3R35 C 1321 3RA35 C 1321 3R35 B 1321 3RA35 B 20DE032 Normal Duty 30 1321 3R35 B 1321 3RA35 B 1321 3R35 B 1321 3RA35 B 20DE041 Heavy Duty 30 1321 3R35 B 1321 3RA35 B 1321 3R45 B 1321 3RA45 B 20DE041 Normal Duty 40 1321 3R45 B 1321 3RA45 B 1321 3R45 B 1321 3RA45 B 20DE052 Heavy Duty 40 1321 3R45 B 1321 3RA45 B 1321 3R55 B 1321 3RA55 B 20DE052 Normal Duty 50 1321 3R55 B 1321 3RA55 B 1321 3R55 B 1321 3RA55 B 20DE062 Heavy Duty 50 1321 3R55 B 1321 3RA55 B 1321 3R80 B 1321 3RA80 B 20DE062 Normal Duty 60 1321 3R80 B 1321 3RA80 B 1321 3R80 B 1321 3RA80 B 20DE077 Heavy Duty 60 1321 3R80 B 1
107. 15 590 590 500 208 240V 60Hz Input 650 650 355 650 650 500 Code 208V 240V Hp 730 730 400 730 730 600 Amps Amps 4P2 4 8 4 2 1 0 6P8 7 8 6 8 2 0 9P6 11 9 6 3 0 015 1755 15 8 5 0 022 25 3 22 7 5 028 32 2 28 10 042 48 3 42 15 052 56 52 20 070 78 2 70 25 080 92 80 30 104 120 104 40 130 130 130 50 154 177 154 60 192 221 192 78 Allen Bradley 131 AC Adjustable Frequency Drives PowerFlex 700S c4 f j ND Rating Documentation Comm Slot 600V 60Hz Input Code Documents Code Version Code Amps Hp E Quick Start Guide N None 022 22 20 N No Documentation C DPI ControlNet Coax 027 27 25 D DPI DeviceNet 032 32 30 E DPI EtherNet IP 041 41 40 Q DPI ControlNet Fiber 052 52 50 g R DPI RIO 062 62 60 Brake S DPI RS 483 DF1 077 77 75 Code w Brake IGBT 1 DriveLogix ControlNet Coax 099 99 100 Y Yes 2 DriveLogix ControlNet Redundant 125 125 125 N No l Coax 144 144 150 Brake IGBT is standard on Frames 1 3 and 2 a Fiber optional on Frames 4 9 ONLY 4 DriveLogix ControlNet Redundant CE Certification testing has not been Fiber performed on 600V class drives 5 DriveLogix DeviceNet Open Conn c5 ND Rating 690V 50 Hz Input Code Amps Hp 052 52 45 060 60 55 082 82 75 098 98 90 119 119 110 142 142 132 CE Certification testing has not been performed on 600V class drives d Enclosure Code Enclosure A IP20 NEMA Type
108. 16 10 15748 62 914 4 36 406 4 16 Allen Bradley 71 AC Adjustable Frequency Drives PowerFlex 70 Packaged Drives Programs Enclosure Selection Enclosure Style for Flange Mounted Drives Ratings NEMA Type 4 12 Indoor AF NEMA Type 3 4 Outdoor AH CB DS FB PowerFlex or NP amp CB DS FB 70 Flange Drive Drive or NP amp Drive Cat Mounted Mounted All Options Drive All Options Normal Duty Heavy Duty Drive Frame No Options Only Options C3 Less Line Mounted Less Line All Options Hp Hp Size 21A or C5 Reactor t All Options Options Reactor 36 208V ac Three Phase Drive Enclosure Selection 0 5 0 33 A X2P2 1 4 5 5 4 5 5 1 0 0 75 A X4P2 1 4 5 5 4 5 6 2 0 1 5 B X6P8 1 4 5 6 4 5 7 3 0 2 0 B X9P6 1 4 5 6 4 5 7 5 0 3 0 C X015 2 4 5 6 5 5 8 7 5 5 0 D X022 3 4 6 7 5 6 9 10 7 5 D X028 3 4 6 7 5 6 10 240V ac Three Phase Drive Enclosure Selection 0 5 0 33 A B2P2 1 4 5 5 4 5 5 1 0 0 75 A B4P2 1 4 5 5 4 5 6 2 0 1 5 B B6P8 1 4 5 6 4 5 7 3 0 2 0 B B9P6 1 4 5 6 4 5 7 5 0 3 0 C B015 2 4 5 6 5 5 8 1 5 5 0 D B022 3 4 6 7 5 6 9 10 7 5 D B028 3 4 6 7 5 6 10 480V ac Three Phase Drive Enclosure Selection 0 5 0 33 A D1P1 1 4 5 5 4 5 5 1 0 0 75 A D2P1 1 4 5 5 4 5 5 2 0 1 5 A D3P4 1 4 5 5 4 5 6 3 0 2 0 B D5P0 1 4 5 6 4 5 7 5 0 3 0 B D8P0 1 4 5 6 4 5 7 1 5 5 0 C D011 2 4 5 6 4 5 8 10 7 5 C D014 2 4 5
109. 2 Allen Bradley AC Adjustable Frequency Drives PowerFlex Drive Packages for Fan amp Pump Applications 460V 60 Hz Three Phase Drive Ratings Input Line Reactor Ouput Line Reactorx IPOO Open Style IP11 NEMA Type 1 IPOO Open Style 1P11 NEMA Type 1 kw Hp Amps Cat No Cat No Cat No Cat No 3 Impedance 0 75 1 0 2 1 1321 3R2 A 1321 3RA2 A 1321 3R2 A 1321 3RA2 A 1 5 2 0 3 4 1321 3R4 B 1321 3RA4 B 1321 3R4 B 1321 3RA4 B 2 2 3 0 5 0 1321 3R8 C 1321 3RA8 C 1321 3R8 C 1321 3RA8 C 4 0 5 0 8 0 1321 3R8 B 1321 3RA8 B 1321 3R8 B 1321 3RA8 B 5 5 7 5 11 1321 3R12 B 1321 3RA12 B 1321 3R12 B 1321 3RA12 B 7 5 10 14 1321 3R18 B 1321 3RA18 B 1321 3R18 C 1321 3RA18 C 11 15 22 1321 3R25 B 1321 3RA25 B 1321 3R25 B 1321 3RA25 B 15 20 27 1321 3R35 B 1321 3RA35 B 1321 3R25 B 1321 3RA25 B 18 5 25 34 1321 3R35 B 1321 3RA35 B 1321 3R35 B 1321 3RA35 B 22 30 40 1321 3R45 B 1321 3RA45 B 1321 3R45 B 1321 3RA45 B 30 40 52 1321 3R55 B 1321 3RA55 B 1321 3R55 B 1321 3RA55 B 37 50 65 1321 3R80 B 1321 3RA80 B 1321 3R80 B 1321 3RA80 B 45 60 77 1321 3R80 B 1321 3RA80 B 1321 3R80 B 1321 3RA80 B 55 75 96 1321 3R100 B 1321 3RA100 B 1321 3R100 B 1321 3RA100 B 75 100 125 1321 3R130 B 1321 3RA130 B 1321 3R130 B 1321 3RA130 B 90 125 156 1321 3R160 B 1321 3RA160 B 1321 3R160 B 1321 3RA160 B 110 150 180 1321 3R200 B 1321 3
110. 2 360 200 150 260 205 286 308 390 410 132 110 20BD248A0ANNANCO 6 Catalog number corresponds to output amps in these columns Drive must be programmed to lower voltage to obtain higher currents shown at right Frame 4 5 and 6 drives have dual current ratings one for normal duty applications and one for heavy duty applications in parenthesis The drive may be operated at either rating gt Rating is limited to 45 C surrounding air Rating is limited to 40 C surrounding air 78 Allen Bradley AC Adjustable Frequency Drives PowerFlex 700 600 690V ac Three Phase Drives 600V ac Input 690V ac Input IP20 NEMA Type 1 Output Amps Normal Heavy Output Amps Normal Heavy Frame Cont 1 Min 3 Sec Duty Hp Duty Hp Cont 1 Min 3 Sec Duty kW Duty kw Cat No Size pe 2 2 6 3 0 5 20BE1P7A0AYNANCO 0 2 7 3 6 4 8 2 1 20BE2P7A0AYNANCO 0 3 9 4 3 5 9 3 2 20BE3P9A0AYNANCO 0 6 1 6 7 9 2 5 3 20BE6P1A0AYNANCO 0 9 9 9 13 5 75 5 20BE9POAOAYNANCO 0 11 13 5 18 10 7 5 20BE011A0AYNANCO 1 17 18 7 25 5 15 10 20BE017A0AYNANCO 1 22 25 5 34 20 15 20BE022A0AYNANCO 2 27 38 44 25 20 20BE027A0AYNANCO 2 32 40 5 54 30 25 20BE032A0AYNANCO 3 41 48 64 40 30 20BE041A0AYNANCO 3 52 61 5 82 50 40
111. 2 0 1321 3R4 Dt 1321 3RA4 Dt 1321 3R4 Dt 1321 3RA4 Dt 20AE3P9 Heavy Duty 2 0 1321 3R4 Dt 1321 3RA4 Dt 1321 3R4 D 1321 3RA4 D 20AE3P9 Normal Duty 3 0 1321 3R4 D 1321 3RA4 D 1321 3R4 D 1321 3RA4 D 20AE6P1 Heavy Duty 3 0 1321 3R4 D 1321 3RA4 D 1321 3R8 D 1321 3RA8 D 20AE6P1 Normal Duty 5 0 1321 3R8 D 1321 3RA8 D 1321 3R8 D 1321 3RA8 D 20AE9PO Heavy Duty 5 0 1321 3R8 D 1321 3RA8 D 1321 3R12 Ct 1321 3RA12 Ct 20AE9PO Normal Duty 7 5 1321 3R12 CH 1321 3RA12 Ct 1321 3R12 CH 1321 3RA12 C 20AE011 Heavy Duty 7 5 1321 3R12 CH 1321 3RA12 C 1321 3R12 C 1321 3RA12 C 20AE011 Normal Duty 10 1321 3R12 C 1321 3RA12 C 1321 3R12 C 1321 3RA12 C 20AE017 Heavy Duty 10 1321 3R12 C 1321 3RA12 C 1321 3R18 C 1321 3RA18 C 20AE017 Normal Duty 15 1321 3R18 C 1321 3RA18 C 1321 3R18 C 1321 3RA18 C 20AE022 Heavy Duty 15 1321 3R18 C 1321 3RA18 C 1321 3R25 C 1321 3RA25 C 20AE022 Normal Duty 20 1321 3R25 C 1321 3RA25 C 1321 3R25 C 1321 3RA25 C 20AE027 Heavy Duty 20 1321 3R25 Ct 1321 3RA25 C 1321 3R35 Ct 1321 3RA35 C 20AE027 Normal Duty 25 1321 3R35 CH 1321 3RA35 C 1321 3R35 CH 1321 3RA35 C 20AE032 Heavy Duty 25 1321 3R35 CH 1321 3RA35 C 1321 3R35 Ct 1321 3RA35 C 20AE032 Normal Duty 30 1321 3R35 CH 1321 3RA35 C 1321 3R35 Ct 1321 3RA35 C 20AE041 Heavy Duty 30 1321 3R35 CH 1321 3RA35 C 1321 3R45 C 1321 3RA45 C 20AE041 Normal Duty 40 1321 3R45 C 1321 3RA45 C 1321 3R45 C 1321 3RA45 C 20AE052 Heavy Duty 40 1321 3R45 C 1321 3RA45 C 1321 3R55 C 1321 3RA55 C 20AE052 Normal Duty 50 132
112. 2 30 45 5 1321 3R45 C 1321 3RA45 C 30 40 60 1321 3R55 C 1321 3RA55 C 37 50 72 1321 3R80 C 1321 3RA80 C 45 60 88 1321 3R80 C 1321 3RA80 C 55 75 105 1321 3R100 C 1321 3RA100 C 75 100 142 1321 3R130 C 1321 3RA130 C 90 125 170 1321 3R160 C 1321 3RA160 C 110 150 208 1321 3R200 C 1321 3RA200 C DC Series Bus Inductors Loose 200 240V 60 Hz Three Phase PowerFlex 400 Drive Ratings IPOO Open Style kw Hp Amps Inductance mH Cat No 2 2 3 0 12 0 92 1321 DC12 1 3 7 5 0 17 5 0 63 1321 DC18 1 5 5 1 9 24 0 85 1321 DC32 1 15 10 33 0 75 1321 DC40 2 380 480V 60 Hz Three Phase PowerFlex 400 Drive Ratings IPOO Open Style kw HP Amps Inductance mH Cat No 2 2 3 0 6 0 3 68 1321 DC9 2 4 0 5 0 10 5 2 1 1321 DC12 2 5 5 7 5 12 3 75 1321 DC18 4 7 5 10 17 1 75 1321 DC25 4 11 15 22 2 68 1321 DC32 2 15 20 30 2 00 1321 DC40 4 Allen Bradley 37 AC Adjustable Frequency Drives PowerFlex 400 EMC Filters Loose 200 240V 50 60 Hz Three Phase PowerFlex 400 Drive Ratings IPOO Open Style kw Hp Amps Cat No 2 2 3 0 12 22 RF034 CS 3 7 5 0 17 5 22 RF034 CS 5 5 1 5 24 22 RF034 CS 7 5 10 33 22 RF034 CS 11 15 49 22 RFD070 15 20 65 22 RFD100 18 5 25 75 22 RFD100 22 30 90 22 RFD150 30 40 120 22 RFD150 37 50 145 22 RFD180 380 480V 50 60 Hz Three Phase PowerFlex 400 Drive Ratings IPOO Open Style kw Hp Amps Cat No
113. 2 Ct 1321 3RA12 C 75 10 11 1321 3R12 C 1321 3RA12 C 1321 3R12 C 1321 3RA12 C 11 15 17 1321 3R18 C 1321 3RA18 C 1321 3R18 C 1321 3RA18 C 15 20 22 1321 3R25 Ct 1321 3RA25 C 1321 3R25 Ct 1321 3RA25 C 18 5 25 27 1321 3R35 Ct 1321 3RA35 C 1321 3R35 Ct 1321 3RA35 C 22 30 32 1321 3R35 Ct 1321 3RA35 C 1321 3R35 Ct 1321 3RA35 C 30 40 41 1321 3R45 C 1321 3RA45 C 1321 3R45 C 1321 3RA45 C 37 50 52 1321 3R55 C 1321 3RA55 C 1321 3R55 C 1321 3RA55 C 45 60 62 1321 3R80 C 1321 3RA80 C 1321 3R80 C 1321 3RA80 C 55 75 77 1321 3R80 C 1321 3RA80 C 1321 3R80 C 1321 3RA80 C 75 100 99 1321 3R100 C 1321 3RA100 C 1321 3R100 C 1321 3RA100 C 90 125 125 1321 3R130 Ct 1321 3RA130 C 1321 3R130 C 1321 3RA130 C 110 150 144 1321 3R160 C 1321 3RA160 C 1321 3R160 C 1321 3RA160 C Input line reactors were sized based on the NEC fundamental motor amps Output line reactors were sized based on the VFD rating output currents 4 impedance reactor 114 Allen Bradley AC Adjustable Frequency Drives PowerFlex 700H Contents Description Page Conformity to Standards this page Description this page Catalog Number Explanation 116 Product Selection 117 User Installed Options 118 Factory Installed Options 121 Conformity to Standards The PowerFlex 700H conforms to the following Standard Conformity to Product UL Listed CSA Certified c UL IEC Designed to Meet CE Approved Allen Bradley SISSI Powe
114. 24F104 7 5 10 33 22B B033N104 C 22B B033F104 Meets IP40 54 65 NEMA 1 12 4 4X when installed in an enclosure of like rating Allen Bradley 15 AC Adjustable Frequency Drives PowerFlex 40 480V ac Three Phase Drives 50 60 Hz No Filter Drive Ratings IP20 NEMA Type Open IP20 Flange Mount Output Current kW Hp A Cat No Frame Size Cat No 0 4 0 5 1 4 22B D1P4N104 B 22B D1P4F104 0 75 1 0 2 3 22B D2P3N104 B 22B D2P3F104 1 5 2 0 4 0 22B D4PON104 B 22B D4P0F104 2 8 3 0 6 0 22B D6PON104 B 22B D6POF104 4 0 5 0 10 5 22B D010N104 B 22B D010F104 5 5 7 5 12 22B D012N104 C 22B D012F104 7 5 10 17 22B D017N104 C 22B D017F104 11 15 24 22B D024N104 C 22B D024F1041 Meets IP40 54 65 NEMA 1 12 4 4X when installed in an enclosure of like rating Requires use of external DC Bus inductor or AC Line Reactor 600V ac Three Phase Drives 50 60 Hz No Filter Drive Ratings IP20 NEMA Type Open IP20 Flange Mount Output Current kw Hp A Cat No Frame Size Cat No 0 75 1 0 1 7 22B E1P7N104 B 22B E1P7F104 15 20 3 0 22B E3PON104 B 22B E3P0F104 2 2 3 0 4 2 22B E4P2N104 B 22B E4P2F104 4 0 5 0 6 6 22B E6P6N104 B 22B E6P6F104 5 5 715 9 9 22B E9P9N104 C 22B E9P9F104 7 5 10 12 22B E012N104 C 22B E012F104 11 15 19 22B E019N104 C 22B E019F104 Meets IP40 54 65 NEMA 1 12 4 4X when installed in an enclosure of like rating 16 Allen Bradley AC Ad
115. 2A A1P4N103 A 0 4 0 5 2 1 22A A2P1N103 A 0 75 1 0 3 6 22A A3P6N103 A 1 5 2 0 6 8 22A A6P8N103 B 22 3 0 9 6 22A A9P6N103 B Meets IP40 54 65 NEMA 1 12 4 4X when installed in an enclosure of like rating This filter is suitable for use with a cable length of up to 10 meters for Class A and 1 meter for Class B environments 240V ac Three Phase Drives 50 60 Hz Drive Ratings IP20 NEMA Type Open IP20 Flange Mount Output Current kw Hp A Cat No Frame Size Cat No With Integral S Type EMC Filter 0 2 0 25 15 22A A1P5N114 A 0 4 0 5 2 3 22A A2P3N114 A 0 75 1 0 4 5 22A A4P5N114 A 1 5 2 0 8 0 22A A8P0N114 B No Filter 0 2 0 25 15 22A A1P5N104 A 22A A1P5F104 0 4 0 5 2 3 22A A2P3N104 A 22A A2P3F104 0 75 1 0 4 5 22A A4P5N104 A 22A A4P5F104 15 2 0 8 0 22A A8P0N104 B 22A A8P0F104 Meets 1P40 54 65 NEMA 1 12 4 4X when installed in an enclosure of like rating This filter is suitable for use with a cable length of up to 10 meters for Class A and 1 meter for Class B environments 480V ac Three Phase Drives Drive Ratings IP20 NEMA Type Open IP20 Flange Mount Output Current kW Hp A Cat No Frame Size Cat No 0 4 0 5 1 4 22A D1P4N104 A 22A D1P4F104 0 75 1 0 2 3 22A D2P3N104 A 22A D2P3F104 1 5 2 0 4 0 22A DA4PON104 A 22A D4P0F104 2 2 3 0 6 0 22A D6PON104 B 22A D6POF104 3 7 5 0 8 7 22A D8P7N104 B 22A D8P7F104 Meets IP40
116. 3 Input Line Reactorx 3 Input Line Reactor only available as integral part of enclosure with Frame C and B drives Allen Bradley AC Adjustable Frequency Drives PowerFlex 400 Packaged Drives Programs Product Selection 208V ac Main Input Disconnect Drive Ratings Single Motor Output Current 40 C kW Hp A Frame Size Cat No 2 2 3 0 12 C 23C X012A103NNAANN 3 7 5 0 16 8 C 23C X017A103NNAANN 5 5 7 5 24 C 23C X024A103NNAANN 7 5 10 30 8 C 23C X033A103NNAANN 11 15 46 2 D 23C X049A103NNAANN 15 20 64 D 23C X065A103NNAANN 18 5 25 75 D 23C X075A103NNAANN 22 30 88 D 23C X090A103NNAANN 30 40 114 E 23C X120A103NNAANN 37 50 143 E 23C X145A103NNAANN 208V ac 3 Contactor Full Feature Bypass with Disconnect Drive Ratings Single Motor Output Current 40 C kW Hp A Frame Size Cat No 2 2 3 0 12 C 23C X012A103NNBANN 3 7 5 0 16 8 C 23C X017A103NNBANN 5 5 7 5 24 C 23C X024A103NNBANN 75 10 30 8 C 23C X033A103NNBANN 11 15 46 2 D 23C X049A103NNBANN 15 20 64 D 23C X065A103NNBANN 18 5 25 75 D 23C X075A103NNBANN 22 30 88 D 23C X090A103NNBANN 30 40 114 E 23C X120A103NNBANN 37 50 143 E 23C X145A103NNBANN 460V ac Main Input Disconnect Drive Ratings Single Motor Output Current 40 C kW Hp A Frame Size Cat No 2 2 3 0 4 8 G 23C D6P0A103NNAANN 4 0 5 0 7 6 Cc 23C D010A103NNAANN 5 5 7 5 11 C 23C D0
117. 3 0 6 0A 284D FHD6P0Z 25 CR 284D FHD6POD 25 CR 284D FHD6POB 25 CR 3 3 5 0 7 6 A 284D FHD7P6Z 25 CR 284D FHD7P6D 25 CR 284D FHD7P6B 25 CR Cat No Input 24V DC 120V AC 240V AC Voltage 3 Phase kW Rating 3 Phase Hp Rating Output Current Control Voltage Control Voltage Control Voltage 200 240v 0 4 0 5 2 3 A 284A FHB2P3Z 10 CR 284A FHB2P3D 10 CR 284A FHB2P3B 10 CR 50 60 Hz l 0 75 1 0 5 0 A 284A FHB4P5Z 10 CR 284A FHB4P5D 10 CR 284A FHB4P5B 10 CR 3 Phase 1 5 2 0 7 6 A 284A FHB7P6Z 25 CR 284A FHB7P6D 25 CR 284A FHB7P6B 25 CR 0 4 0 5 14A 284A FHD1P4Z 10 CR 284A FHD1P4D 10 CR 284A FHD1P4B 10 CR 380 480V 0 75 1 0 2 3A 284A FHD2P3Z 10 CR 284A FHD2P3D 10 CR 284A FHD2P3B 10 CR 50 60 Hz 1 5 2 0 4 0 A 284A FHD4P0Z 10 CR 284A FHD4P0D 10 CR 284A FHD4POB 10 CR 3 Phase 2 2 3 0 6 0A 284A FHD6POZ 25 CR 284A FHD6POD 25 CR 284A FHD6POB 25 CR 3 3 5 0 7 6 A 284A FHD7P6Z 25 CR 284A FHD7P6D 25 CR 284A FHD7P6B 25 CR 29 Bulletin 280 281 283 284 ArmorStart Distributed Motor Controllers Product Line Overview gt E 5 a Bulletin Bulletin Bulletin Bulletin Bulletin Bulletin 280D 281D 280A 281A 283D 283A 284D 284A Horsepower Range 0 5 10 Hp 0 37 7 5 kW Y Y 0 5 10 Hp 0 37 5 5 kW Y Y 0 5 5 Hp 0 4 3 3 kW Y Y Starting Method Full Voltage
118. 321 3R4 B 1321 3RA4 B 1321 3R8 C 1321 3RA8 C 20AD5P0 Normal Duty 3 0 1321 3R8 C 1321 3RA8 C 1321 3R8 C 1321 3RA8 C 20AD8P0 Heavy Duty 3 0 1321 3R8 C 1321 3RA8 C 1321 3R8 B 1321 3RA8 B 20AD8PO Normal Duty 5 0 1321 3R8 B 1321 3RA8 B 1321 3R8 B 1321 3RA8 B 20AD011 Heavy Duty 5 0 1321 3R8 B 1321 3RA8 B 1321 3R12 B 1321 3RA12 B 20AD011 Normal Duty 1 5 1321 3R12 B 1321 3RA12 B 1321 3R12 B 1321 3RA12 B 20AD014 Heavy Duty 7 5 1321 3R12 B 1321 3RA12 B 1321 3R18 B 1321 3RA18 B 20AD014 Normal Duty 10 1321 3R18 B 1321 3RA18 B 1321 3R18 B 1321 3RA18 B 20AD022 Heavy Duty 10 1321 3R18 B 1321 3RA18 B 1321 3R25 B 1321 3RA25 B 20AD022 Normal Duty 15 1321 3R25 B 1321 3RA25 B 1321 3R25 B 1321 3RA25 B 20AD027 Heavy Duty 15 1321 3R25 B 1321 3RA25 B 1321 3R25 B 1321 3RA25 B 20AD027 Normal Duty 20 1321 3R35 B 1321 3RA35 B 1321 3R25 B 1321 3RA25 B 20AD034 Heavy Duty 20 1321 3R35 B 1321 3RA35 B 1321 3R35 B 1321 3RA35 B 20AD034 Normal Duty 25 1321 3R35 B 1321 3RA35 B 1321 3R35 B 1321 3RA35 B 20AD040 Heavy Duty 25 1321 3R35 B 1321 3RA35 B 1321 3R45 B 1321 3RA45 B 20AD040 Normal Duty 30 1321 3R45 B 1321 3RA45 B 1321 3R45 B 1321 3RA45 B 20AD052 Heavy Duty 30 1321 3R45 B 1321 3RA45 B 1321 3R55 B 1321 3RA55 B 20AD052 Normal Duty 40 1321 3R55 B 1321 3RA55 B 1321 3R55 B 1321 3RA55 B 20AD065 Heavy Duty 40 1321 3R55 B 1321 3RA55 B 1321 3R80 B 1321 3RA80 B 20AD065 Normal Duty 50 1321 3R80 B 1321 3RA80 B 1321 3R80 B 1321 3RA80 B Input line reactors were sized b
119. 321 3RA80 B 1321 3R80 B 1321 3RA80 B 20DE077 Normal Duty 75 1321 3R80 B 1321 3RA80 B 1321 3R80 B 1321 3RA80 B 20DE099 Heavy Duty 75 1321 3R80 B 1321 3RA80 B 1321 3R80 B 1321 3RA80 B 20DE099 Normal Duty 100 1321 3R100 B 1321 3RA100 B 1321 3R100 B 1321 3RA100 B 20DE125 Heavy Duty 100 1321 3R100 B 1321 3RA100 B 1321 3R100 B 1321 3RA100 B 20DE125 Normal Duty 125 1321 3R130 B 1321 3RA130 B 1321 3R130 B 1321 3RA130 B 20DE144 Heavy Duty 125 1321 3R130 B 1321 3RA130 B 1321 3R130 B 1321 3RA130 B 20DE144 Normal Duty 150 1321 3R160 B 1321 3RA160 B 1321 3R160 B 1321 3RA160 B Input line reactors were sized based on the NEC fundamental motor amps Output line reactors were sized based on the VFD rated output currents Allen Bradley 141 AC Adjustable Frequency Drives PowerFlex 700S Input and Output Line Reactors 600V 60 Hz Three Phase 5 Impedance Input Line Reactor Output Line Reactor IPOO Open Style IP11 NEMA Type 1 IPOO Open Style IP11 NEMA Type 1 Drive Cat No Duty Hp Cat No Cat No Cat No Cat No 20DE1P7 Heavy Duty 0 5 1321 3R1 B 1321 3RA1 B 1321 3R2 C 1321 3RA2 C 20DE1P7 Normal Duty 1 1321 3R2 C 1321 3RA2 C 1321 3R2 C 1321 3RA2 C 20DE2P7 Heavy Duty 1 1321 3R2 C 1321 3RA2 C 1321 3R4 D 1321 3RA4 D 20DE2P7 Normal Duty 2 1321 3R4 D 1321 3RA4 D 1321 3R4 Dt 1321 3R
120. 35 C 20AE027 Normal Duty 25 1321 3R35 C 1321 3RA35 C 1321 3R35 C 1321 3RA35 C 20AE032 Heavy Duty 25 1321 3R35 C 1321 3RA35 C 1321 3R35 B 1321 3RA35 B 20AE032 Normal Duty 30 1321 3R35 B 1321 3RA35 B 1321 3R35 B 1321 3RA35 B 20AE041 Heavy Duty 30 1321 3R35 B 1321 3RA35 B 1321 3R45 B 1321 3RA45 B 20AE041 Normal Duty 40 1321 3R45 B 1321 3RA45 B 1321 3R45 B 1321 3RA45 B 20AE052 Heavy Duty 40 1321 3R45 B 1321 3RA45 B 1321 3R55 B 1321 3RA55 B 20AE052 Normal Duty 50 1321 3R55 B 1321 3RA55 B 1321 3R55 B 1321 3RA55 B Input line reactors were sized based on the NEC fundamental motor amps Output line reactors were sized based on the VFD rated output currents Allen Bradley 59 AC Adjustable Frequency Drives PowerFlex 70 Input and Output Line Reactors 600V 60 Hz Three Phase 5 Impedance Input Line Reactor Output Line Reactor IPOO Open Style IP11 NEMA Type 1 IPOO Open Style IP11 NEMA Type 1 Drive Cat No Duty Hp Cat No Cat No Cat No Cat No 20AEOP9 Heavy Duty 0 33 1321 3R1 A 1321 3RA1 A 1321 3R1 B 1321 3RA1 B 20AEOP9 Normal Duty 0 5 1321 3R1 B 1321 3RA1 B 1321 3R1 B 1321 3RA1 B 20AE1P7 Heavy Duty 0 75 1321 3R2 C 1321 3RA2 C 1321 3R2 C 1321 3RA2 C 20AE1P7 Normal Duty 1 0 1321 3R2 C 1321 3RA2 C 1321 3R2 C 1321 3RA2 C 20AE2P7 Heavy Duty 1 5 1321 3R2 B 1321 3RA2 B 1321 3R4 Dt 1321 3RA4 Dt 20AE2P7 Normal Duty
121. 3RA12 C 20BE9PO Normal Duty 7 5 1321 3R12 C 1321 3RA12 C 1321 3R12 G 1321 3RA12 C 20BE011 Heavy Duty 7 5 1321 3R12 C 1321 3RA12 C 1321 3R12 B 1321 3RA12 B 20BE011 Normal Duty 10 1321 3R12 B 1321 3RA12 B 1321 3R12 B 1321 3RA12 B 20BE017 Heavy Duty 10 1321 3R12 B 1321 3RA12 B 1321 3R18 B 1321 3RA18 B 20BE017 Normal Duty 15 1321 3R18 B 1321 3RA18 B 1321 3R18 B 1321 3RA18 B 20BE022 Heavy Duty 15 1321 3R18 B 1321 3RA18 B 1321 3R25 B 1321 3RA25 B 20BE022 Normal Duty 20 1321 3R25 B 1321 3RA25 B 1321 3R25 B 1321 3RA25 B 20BE027 Heavy Duty 20 1321 3R25 B 1321 3RA25 B 1321 3R35 C 1321 3RA35 C 20BE027 Normal Duty 25 1321 3R35 C 1321 3RA35 C 1321 3R35 C 1321 3RA35 C 20BE032 Heavy Duty 25 1321 3R35 C 1321 3RA35 C 1321 3R35 B 1321 3RA35 B 20BE032 Normal Duty 30 1321 3R35 B 1321 3RA35 B 1321 3R35 B 1321 3RA35 B 20BE041 Heavy Duty 30 1321 3R35 B 1321 3RA35 B 1321 3R45 B 1321 3RA45 B 20BE041 Normal Duty 40 1321 3R45 B 1321 3RA45 B 1321 3R45 B 1321 3RA45 B 20BE052 Heavy Duty 40 1321 3R45 B 1321 3RA45 B 1321 3R55 B 1321 3RA55 B 20BE052 Normal Duty 50 1321 3R55 B 1321 3RA55 B 1321 3R55 B 1321 3RA55 B 20BE062 Heavy Duty 50 1321 3R55 B 1321 3RA55 B 1321 3R80 B 1321 3RA80 B 20BE062 Normal Duty 60 1321 3R80 B 1321 3RA80 B 1321 3R80 B 1321 3RA80 B 20BE077 Heavy Duty 60 1321 3R80 B 1321 3RA80 B 1321 3R80 B 1321 3RA80 B 20BE077 Normal Duty 75 1321 3R80 B 1321 3RA80 B 1321 3R80 B 1321 3RA80 B 20BE099 Heavy Duty 75 1321 3R80 B 1321 3RA80 B 1321 3R80 B 1321 3RA80 B 20BE099 Normal Duty
122. 3RA25 A 1321 3R35 A 1321 3RA35 A 20DB028 Normal Duty 10 1321 3R35 A 1321 3RA35 A 1321 3R35 A 1321 3RA35 A 20DB042 Heavy Duty 10 1321 3R35 A 1321 3RA35 A 1321 3R45 A 1321 3RA45 A 20DB042 Normal Duty 15 1321 3R45 A 1321 3RA45 A 1321 3R45 A 1321 3RA45 A 20DB052 Heavy Duty 15 1321 3R45 A 1321 3RA45 A 1321 3R55 A 1321 3RA55 A 20DB052 Normal Duty 20 1321 3R55 A 1321 3RA55 A 1321 3R55 A 1321 3RA55 A 20DB070 Heavy Duty 20 1321 3R55 A 1321 3RA55 A 1321 3R80 A 1321 3RA80 A 20DB070 Normal Duty 25 1321 3R80 A 1321 3RA80 A 1321 3R80 A 1321 3RA80 A 20DB080 Heavy Duty 25 1321 3R80 A 1321 3RA80 A 1321 3R80 A 1321 3RA80 A 20DB080 Normal Duty 30 1321 3R80 A 1321 3RA80 A 1321 3R80 A 1321 3RA80 A 20DB104 Heavy Duty 30 1321 3R80 A 1321 3RA80 A 1321 3R80 A 1321 3RA80 A 20DB104 Normal Duty 40 1321 3R100 A 1321 3RA100 A 1321 3R100 A 1321 3RA100 A 20DB130 Heavy Duty 40 1321 3R100 A 1321 3RA100 A 1321 3R100 A 1321 3RA100 A 20DB130 Normal Duty 50 1321 3R130 A 1321 3RA130 A 1321 3R130 A 1321 3RA130 A 20DB154 Heavy Duty 50 1321 3R130 A 1321 3RA130 A 1321 3R130 A 1321 3RA130 A 20DB154 Normal Duty 60 1321 3R160 A 1321 3RA160 A 1321 3R160 A 1321 3RA160 A 20DB192 Heavy Duty 60 1321 3R160 A 1321 3RA160 A 1321 3R160 A 1321 3RA160 A 20DB192 Normal Duty 75 1321 3R200 A 1321 3RA200 A 1321 3R200 A 1321 3RA200 A 20DB260 Heavy Duty 75 1321 3R200 A 1321 3RA200 A 1321 3R200 A 1321 3RA200 A 20DB260 Normal Duty 100 1321 3RB250 A 1321 3RAB250 A 1321 3RB250 A 1321 3
123. 4 5 5 7 5 C 033 30 8 7 5 10 C 049 46 2 11 15 D 065 64 15 20 D 075 75 18 5 25 D 090 88 22 30 D 120 114 30 40 E 145 143 37 50 E Packaged amp ratings may differ from stand alone drive ratings Packaged drives sized per NEC motor amps 40 Rating Reserved Rating Reserved J Package Description Main Input Disconnect 3 Contactor Full Feature Bypass with Disconnect Position 11 12 13 14 15 16 0 3 N N B A f g h i j k c2 Rating Code 460V 60Hz Input N Code Amps kW Hp Frame 6PO 4 8 2 2 3 0 C 010 7 6 4 0 5 0 C Code 012 11 5 5 7 5 C N 017 14 7 5 10 C 022 21 11 15 C 030 27 15 20 C 038 34 18 5 25 D 045 40 22 30 D Code 060 52 30 40 D A 072 65 37 50 E B 088 Lf 45 60 E 105 96 55 75 E C 142 124 75 100 E 170 156 90 125 F 208 180 110 150 F Packaged amp ratings may differ from stand alone drive ratings Packaged drives sized per Code NECmotoramps A d Enclosure Gada Code Enclosure N A NEMA Type 1 E Code HIM N Code Interface Module 1 Fixed Keypad f Code Emission Class EI Code Rating 0 Not Filtered Package Code A g Version Code Version 3 RS485 D DeviceNet Adapter E EtherNet IP Adapter P PROFIBUS DP Adapter wy 3 Contactor Basic Bypass with Disconnect k Control Description Single Motor Rating Reserved m Rating Reserved n Options Description
124. 40 5 54 30 25 E032A0ENYANNNN 3 41 48 64 40 30 E041A0ENYANNNN 3 52 61 5 82 50 40 E052A0ENYANNNN 3 62 78 104 60 50 E062A0ENNANNNN 4 77 63 85 94 116 126 75 60 82 60 90 90 120 123 75 55 E077A0ENNANNNN 5 99 77 109 116 126 138 100 75 98 82 5 108 123 127 140 90 75 E099A0ENNANNNN 5 125 99 138 149 188 198 125 100 119 98 131 147 179 196 110 90 E125A0ENNANNNN 6 144 125 158 188 216 250 150 125 142 119 156 179 213 238 132 110 E144A0ENNANNNN 6 Catalog number corresponds to output amps in this column Drive must be programmed to lower voltage to obtain higher currents shown at right These drives have dual current ratings one for normal duty applications and one for heavy duty applications in parenthesis The drive may be operated at either rating 8 Rating is limited to 40 C surrounding air CE Certification testing has not been performed on 600V class drives User Installed Options Phase I amp Il Drives Human Interface and Wireless Interface Modules No HIM Blank Plate LCD Digital Speed LCD Full Numeric LCD Programmer Only DPI NEMA 1 WIM 20 HIM AO 20 HIM A2 20 HIM A3 20 HIM A5 20 WIM N1 Remote Panel Mount Remote Panel Mount Remote Panel Mount Remote Panel Mount DPI NEMA 4 WIM Full Numeric Full Numeric Programmer Only Programmer Only Remote Panel Mount 20 HIM C3 20 HIM C3S 20 HI
125. 40 Code Amps kW Hp al Fixed Keypad 1P4 1 4 0 4 0 5 b 2P3 2 3 0 75 1 0 f Voltage Rating Ano 40 1 5 2 0 Emission Class Code Voltage Ph 650 6 0 2 2 3 0 Code Rating V 120V ac 1 uM 108 40 6 0 0 Not Filtered 240V ac 1 oig 12 3805 1 Filtered B 240V ac 3 017 17 7 5 10 D 480V ac 3 024 24 11 15 E 600V ac 3 g a c5 Version Code Version c1 oa 3 No Brake IGBT Rating 460 600V Three Phase Input Standard 100 120V Single Phase Input Code Amps kW Hp This position of the Catalog Number now Code Amps kW Hp 1P7 1 7 0 75 1 0 indicates drive version All PowerFlex 40 drives 2P3 2 8 0 4 0 5 3PO 3 0 1 5 2 0 are equipped with RS485 communication 5PO 5 0 0 75 1 0 dE a2 2 2 3 0 SET 50 114 5 6P6 6 6 4 0 5 0 h 989 9 9 5 5 7 5 Optional T un Rating AA through ZZ ao 200 240V Single Phase Input Code Amps kW Hp d 2P3 2 3 0 4 0 5 Enclosure 5PO 50 0 75 1 0 Code Enclosure 8PO 8 0 1 5 2 0 N Panel Mount IP 20 012 12 2 2 3 0 NEMA Iypo Open F Flange Mount IP 20 NEMA Type Open c3 Replacement Plate Rating Drive IP 20 NEMA H Type Open 200 240V Three Phase Input Contact factory for Code Amps kW Hp ordering information 2P3 2 3 0 4 0 5 5PO 5 0 0 75 1 0 8P0 8 0 1 5 2 0 012 12 2 2 3 0 017 17 5 3 7 5 0 024 24 5 5 7 5 033 33 7 5 10 14 Allen Bradley Product Selection 120V ac Single Phase Drives 50 60 Hz No Filter AC Adjustable Frequency Drives PowerFlex 40
126. 44 444 250 200 300 245 330 368 444 444 160 132 300A0ANNBNNO 9 385 300 424 450 540 540 300 250 385 300 424 450 540 540 200 160 385A0ANNBNNO 10 460 385 506 578 693 693 350 300 460 385 506 578 693 693 250 200 460A0ANNBNNO 10 500 420 550 630 828 828 450 350 500 420 550 630 828 828 250 250 500A0ANNBNNO 10 590 520 649 780 956 956 500 450 590 520 649 780 956 956 315 250 590A0ANNBNNO 11 650 590 715 885 1062 1062 500 500 650 590 715 885 1062 1062 355 315 650A0ANNBNNO 11 730 650 803 975 1095 1170 600 500 730 650 803 975 1095 1170 400 355 730A0ANNBNNO 11 820 730 902 1095 1230 1314 700 600 820 730 902 1095 1230 1314 450 400 820A0ANNBNNO 12 920 820 1012 1230 1380 1476 800 700 920 820 1012 1230 1380 1476 500 450 920A0ANNBNNO 12 1030 920 1133 1370 1555 1600 900 800 1030 920 t 1133 1370 1555 1600 560 500 1KOAOANNBNNO 12 These drives have dual current ratings one for normal duty applications and one for heavy duty applications in parenthesis The drive may be operated at either rating The 2 sec output current is only available at initial start or drive operating at light load Heavy duty rating is limited to 35 C surrounding air 600 690V ac Three Phase Drives 600V ac Input 690V ac Input 1P21 NEMA Type 1 Output Amps Normal Heavy Output Amps Normal Heavy Cat No C
127. 480V ac Three Phase Drives 480V ac Input 380 400V ac Input Output Amps Normal Heavy Output Amps Normal Heavy Frame Cont 1 Min 3 Sec Duty Hp Duty Hp Cont 1 Min 3 Sec Duty kW Duty kW Cat No Size 11 12 1 6 0 5 0 33 13 14 19 0 37 0 25 20BD1P1AOAYNANCO 0 24 24 3 2 1 0 75 24 24 3 2 0 75 0 55 20BD2P1AOAYNANCO 0 3 4 45 6 2 15 35 45 6 15 0 75 20BD3P4A0AYNANCO 0 5 55 75 3 2 5 55 75 22 15 20BDSPOAOAYNANCO 0 8 8 8 12 5 3 87 9 9 13 2 4 22 20BD8POAOAYNANCO 0 11 124 16 5 75 5 115 18 174 5 5 4 20BDO11A0AYNANCO 0 14 16 5 22 10 75 154 172 23 1 75 5 5 20BD014A0AYNANCO 1 22 24 2 33 15 10 22 242 33 11 75 20BD022A0AYNANCO 1 27 33 44 20 15 30 33 45 15 11 20BD027A0AYNANCO 2 34 40 5 54 25 20 37 45 60 18 5 15 20BDO34ADAYNANCO 2 40 51 68 30 25 43 56 74 22 18 5 20BDO40A0AYNANCO 3 52 60 80 40 30 56 64 86 30 22 20BDO52A0AYNANCO 3 65 78 104 50 40 72 84 112 37 30 20BDO65A0AYNANCO 3 77 65 85 98 116 130 60 50 85 72 gt 94 108 128 144 45 37 20BD077A0ANNANCO 4 96 77 106 116 144 154 75 60 105 85 116 128 1158 170 55 45 20BDO96ADANNANCO 5 125 96 138 144 163 168 100 75 125 96 138 144 1163 168 55 45 20BD125A0ANNANCO 5 156 125 172 188 233 250 1125 100 170 140 187 210 255 280 90 75 20BD156A0ANNANCO 6 180 156 198 234 270 812 150 125 205 170 220 255 289 313 110 90 20BD180A0ANNANCO 6 180 073 270 37
128. 5 Allen Bradley AC Adjustable Frequency Drives PowerFlex 400 Product Selection 200 240V ac Three Phase Drives Drive Ratings Panel Mount Flange Mount Output Current kW Hp A Frame Size Rating Cat No Cat No 2 8 3 0 12 C IP20 UL Open Type 22C B012N103 22C B012F103 3 7 5 0 17 5 Cc IP20 UL Open Type 22C B017N103 22C B017F103 5 5 75 24 C IP20 UL Open Type 22C B024N103 22C B024F103 75 10 33 Cc IP20 UL Open Type 22C B033N103 22C B033F103 11 15 49 D IP30 NEMA 1 UL Type 1 22C B049A103 15 20 65 D IP30 NEMA 1 UL Type 1 22C B065A103 18 5 25 75 D IP30 NEMA 1 UL Type 1 22C B075A103 22 30 90 D IP30 NEMA 1 UL Type 1 22C B090A103 30 40 120 E IP30 NEMA 1 UL Type 1 22C B120A103 37 50 145 E IP30 NEMA 1 UL Type 1 22C B145A103 Drive terminals are sized according to UL Depending on operating ambient and wire used some local or national codes may require a larger wire size than what the power terminals can accept Multiple conductors 90 C wire and or lugs may be required Refer to the PowerFlex 400 User Manual for details on terminal block wire ranges IP30 NEMA 1 UL Type 1 can be achieved for panel mount drives with top cover and optional conduit box kit installed Field installed conversion kit specified under User Installed Options 380 480V ac Three Phase Drives Drive Ratings Panel Mount Flange Mount Outpu
129. 5 0 37 B4P2A0EYNANANE 1 6 8 9 0 12 2 0 1 5 7 8 10 4 13 8 1 5 0 75 B6P8AOEYNANANE 1 9 6 10 6 14 4 3 0 2 0 11 12 1 17 2 2 1 5 B9P6AOEYNANANE 1 15 3 16 8 23 5 0 3 0 17 5 19 3 26 3 4 0 2 2 BO15A0EYNANANE 1 22 24 2 33 1 5 5 0 25 3 27 8 38 5 5 4 0 B022A0EYNANANE 1 28 33 44 10 7 5 32 2 38 50 6 7 5 5 5 BO28A0EYNANANE 2 42 46 2 63 15 10 48 3 53 1 72 5 11 1 8 BO42A0EYNANANE 3 52 63 80 20 15 56 64 86 15 11 BO52A0EYNANANE 3 70 78 105 25 20 78 2 86 117 3 18 5 15 BO7OAOENNANANE 4 80 105 136 30 25 92 117 3 156 4 22 18 5 BO80AOENNANANE 4 104 80 115 120 175 160 40 30 120 92 132 138 175 175 30 22 B104A0ENNANANE 5 130 104 143 156 175 175 50 40 130 104 143 156 175 175 30 30 B130A0ENNANANE 5 154 130 169 195 231 260 60 50 177 150 195 225 266 300 45 37 B154A0ENNANANE 6 192 154 211 231 288 308 75 60 221 177 243 266 308 308 55 45 B192A0ENNANANE 6 260 205 286 305 390 410 100 75 260 205 286 305 390 410 66 55 B260A0ENNANANE 6 Catalog number corresponds to output amps in this column Drive must be programmed to lower voltage to obtain higher currents shown at right These drives have dual current ratings one for normal duty applications and one for heavy duty applications in parenthesis The drive may be operated at either rating 126 Allen Bradley AC Adjustable Frequency Drives PowerFlex 700S 380 480V ac Three Phase
130. 5 10 14 16 5 22 C 21VD014A0AYNANCOAN 11 15 22 24 2 33 D 21VD022A0AYNANCOAN 15 20 27 33 44 D 21VD027A0AYNANCOAN 18 5 25 34 40 5 54 D 21VD034A0AYNANCOAN 22 30 40 51 68 D 21VD040A0AYNANCOAN 30 40 52 60 80 E 21VD052A0AYNANCOAN 37 50 65 78 104 E 21VD065A0AYNANCOAN 45 60 77 85 116 4 21WD077A0AYNANAOAN 55 75 96 106 144 5 21WD096A0AYNANAOAN 75 100 125 138 163 5 21WD125A0AYNANAOAN 90 125 156 172 233 6 21WD156A0AYNANAOAN 110 150 180 198 270 6 21WD180A0AYNANAOAN 132 200 248 273 372 6 21WD248A0AYNANAOAN Allen Bradley 107 AC Adjustable Frequency Drives PowerFlex Drive Packages for Fan amp Pump Applications 460V ac 3 Contactor Full Feature Bypass with Disconnect Package Code B NEMA Type 1 without HIM 8 Drive Ratings Communication Adapter Output Current kW Hp Cont 1 Min 3 Sec Frame Size Cat No 0 75 1 0 2 1 2 4 3 2 B 21VD2P1A0AYNANCOBN 1 5 2 0 3 4 4 5 6 0 B 21VD3P4A0AYNANCOBN 2 8 3 0 5 0 5 5 7 5 B 21VD5POAOAYNANCOBN 4 0 5 0 8 0 8 8 12 B 21VD8POAOAYNANCOBN 5 5 TS 11 121 16 5 C 21VD011A0AYNANCOBN 78 10 14 16 5 22 C 21VD014A0AYNANCOBN 13 15 22 24 2 33 D 21VD022A0AYNANCOBN 15 20 27 33 44 D 21VD027A0AYNANCOBN 18 5 25 34 40 5 54 D 21VD034A0AYNANCOBN 22 30 40 51 68 D 21VD040A0AYNANCOBN 30 40 52 60 80 E 21VD052A0AYNANCOBN 37 50 65 78 104 E 21VD065A0AYNANCOBN 45 60 77 85 116 4 21WD077A0AYNANAOBN 55 75 96 106 144 5 21WD096A0AYNANAOBN 15 100 125 138 163 5 21WD
131. 5 A E1P7 AO EP AO AO AO AO A26 2 7 3 6 4 8 2 0 1 0 A E2P7 AO E2P7 AO AO AO AO A26 3 9 4 3 5 8 3 0 1 5 B E3P9 AO E3P9 AO AO AO AO A26 6 1 6 7 9 1 5 0 3 0 B E6P1 AO E6P1 AO AO AO AO A26 9 0 9 9 13 5 7 5 5 0 C E9PO AO E9PO AO AO AO AO A26 11 13 5 18 10 75 C E011 A0 E011 AO AO AO AO A26 17 18 7 25 5 15 10 D E017 A0 E017 AO AO AO AO A26 22 25 5 34 20 15 D E022 A0 E022 AO AO AO AO A26 Supports the Standard Control version of the PowerFlex 70 Base drive catalog number includes PowerFlex 70 drive base enclosure and user manual Does not include or require drive input fusing t When FB is selected the power disconnecting means is user supplied Applies to NEMA Type 1 drives only Important If CB DS or FB is not selected power disconnecting means and drive branch circuit protection must be supplied by user gt 600V Only Pricing does not apply to NEMA Type 1 drives CB option not available for 600V NEMA Type 1 drives 3 Indoor AF IP65 NEMA Type 4 12 or Outdoor AH IP65 NEMA Type 3 4 66 Allen Bradley AC Adjustable Frequency Drives PowerFlex 70 Packaged Drives Programs Product Selection continued Optional Choose Any or All 115V Control Manual Bypass Line Reactor Line Reactor Line Reactor Line Reactor Power Output Choo
132. 5 C 1321 3RA55 C 20DE062 Heavy Duty 50 1321 3R55 C 1321 3RA55 C 1321 3R80 C 1321 3RA80 C 20DE062 Normal Duty 60 1321 3R80 C 1321 3RA80 C 1321 3R80 C 1321 3RA80 C 20DE077 Heavy Duty 60 1321 3R80 C 1321 3RA80 C 1321 3R80 C 1321 3RA80 C 20DE077 Normal Duty 75 1321 3R80 C 1321 3RA80 C 1321 3R80 C 1321 3RA80 C 20DE099 Heavy Duty 75 1321 3R80 C 1321 3RA80 C 1321 3R80 C 1321 3RA80 C 20DE099 Normal Duty 100 1321 3R100 C 1321 3RA100 C 1321 3R100 C 1321 3RA100 C 20DE125 Heavy Duty 100 1321 3R100 C 1321 3RA100 C 1321 3R100 C 1321 3RA100 C 20DE125 Normal Duty 125 1321 3R130 C 1321 3RA130 C 1321 3R130 Ct 1321 3RA130 C 20DE144 Heavy Duty 125 1321 3R130 Ct 1321 3RA130 C 1321 3R130 Ct 1321 3RA130 C 20DE144 Normal Duty 150 1321 3R160 C 1321 3RA160 C 1321 3R160 C 1321 3RA160 C Input line reactors were sized based on the NEC fundamental motor amps Output line reactors were sized based on the VFD rated output currents 4 impedance 142 Allen Bradley AC Adjustable Frequency Drives PowerFlex 700S Drive Application Software Drive Application Software brings together an outstanding range of application experience and performance drive products to provide the user with pre engineered and cost effective drive application solutions The following Application Modules are available for installation and use exclusively in the PowerFlex 700S AC drives with DriveLogix that are provided to customers The Drive Application Software is li
133. 54 65 NEMA 1 12 4 4X when installed in an enclosure of like rating amp amp 5 Allen Bradley AC Adjustable Frequency Drives PowerFlex 4 User Installed Options IP30 NEMA 1 UL Type 1 Conversion Kit Description Field installed kit Converts drive to IP30 NEMA Cat No 22 JBAA 1 UL Type 1 enclosure Includes conduit box with mounting screws and plastic top panel B 22 JBAB Human Interface Module Option Kits and Accessories Description Cat No LCD Display Remote Panel Mount Digital Speed Control CopyCat capable IP66 NEMA Type 4X 12 indoor use only 22 HIM C2S Includes 2 0 meter cable LCD Display Remote Panel Mount Digital Speed Control CopyCat capable IP66 NEMA Type 4X 12 indoor use only 22 HIM C2 Includes 2 9 meter cable LCD Display Remote Handheld Digital Speed Control Full Numeric Keypad CopyCat capable IP30 NEMA Type 1 22 HIM A3 Includes 1 0 meter cable Panel Mount with optional Bezel Kit Remote Handheld Wireless Interface Module with Bluetooth technology IP30 NEMA Type 1 Panel Mount 22 WIM N1 with optional Bezel Kit Remote Panel Mount Wireless Interface Module with Bluetooth technology IP66 NEMA Type 4X 12 indoor use 22 WIM N4S only Bezel Kit Panel Mount for LCD Display Remote Handheld unit IP30 NEMA Type 1 Includes a 22 RJ45CBL C20 22 HIM B1 cable DSI HIM Cable DSI HIM to RJ45 cable 1 0 Meter 3 3 Feet 22 HIM H10 2 9 Meter 9
134. 55 D2P1AOEYNANNNN 1 3 4 4 5 6 2 15 3 5 4 5 6 1 5 0 75 D3P4A0EYNANNNN 1 5 5 5 7 5 3 2 5 5 5 7 5 2 2 15 D5POAOEYNANNNN 1 8 8 8 12 5 3 8 7 9 9 13 2 4 2 2 D8POAOEYNANNNN 1 11 12 1 16 5 7 5 5 11 5 13 17 4 5 5 4 DO11A0EYNANNNN 1 14 16 5 22 10 7 5 15 4 17 2 23 1 7 5 5 5 DO14A0EYNANNNN 1 22 24 2 33 15 10 22 24 2 33 11 15 D022A0EYNANNNN 1 27 33 44 20 15 30 33 45 15 11 D027A0EYNANNNN 2 34 40 5 54 25 20 37 45 60 18 5 15 DO34A0EYNANNNN 2 40 51 68 30 25 43 56 74 22 18 5 DO40A0EYNANNNN 3 52 60 80 40 30 56 64 86 30 22 D052A0EYNANNNN 3 65 78 104 50 40 72 84 112 37 30 DO65A0EYNANNNN 3 77 65 85 98 116 130 60 50 85 72 94 108 128 144 45 37 D077A0ENNANNNN 4 96 77 106 116 144 154 75 60 105 85 116 128 158 170 55 45 D096 AOENNANNNN 5 125 96 138 144 163 168 100 75 125 96 138 144 163 168 55 45 D125A0ENNANNNN 5 156 125 172 188 233 250 125 100 170 140 187 210 255 280 90 75 D156A0ENNANNNN 6 180 156 198 234 270 312 150 125 205 170 8 220 255 289 313 110 90 D180A0ENNANNNN 6 248 180 273 270 372 360 200 150 260 205 286 308 390 410 132 110 D248A0ENNANNNN 6 261 205 287 308 410 410 200 150 261 205 287 308 410 410 132 110 D261A0ENNBNNNN 9 300 245 330 368 450 490 250 200 300 245 330 368 450 490 160 132 D300A0ENNBNNNN 9 385 300 424 450 600 600 300 250 385 300 424 450 600 600 200 160 D385A0ENNBNNNN 10 460 385 506 578 770
135. 5P7 AS 22 RF5P7 AL za 15 2 0 22 RF5P7 AS 22 RF5P7 AL 2 2 3 0 22 RF012 BS 22 RF012 BL 3 7 5 0 22 RF012 BS 22 RF012 BL This filter is suitable for use with a cable length of up to 10 meters for Class A and 1 meter for Class B environments Drives are available in these ratings with internal S Type filters t This filter is suitable for use with a cable length of up to 100 meters for Class A and 5 meters for Class B environments 8 The piggyback mounting option cannot be used with Frame B PowerFlex 4 drives and Frame C EMC Line Filters Allen Bradley 11 AC Adjustable Frequency Drives PowerFlex 4 Dynamic Brake Resistors Drive Ratings Minimum Resistance Input Voltage kW Hp Q Cat No 0 2 0 25 48 AK R2 091P500 a 0 4 0 5 48 AK R2 091P500 0 75 1 0 48 AK R2 091P500 0 2 0 25 48 AK R2 091P500 240V 50 60 Hz 0 4 0 5 48 AK R2 091P500 1 Phase 0 75 1 0 48 AK R2 091P500 1 5 2 0 48 AK R2 091P500 0 2 0 25 48 AK R2 091P500 0 4 0 5 48 AK R2 091P500 240V 50 60 Hz 0 75 1 0 48 AK R2 091P500 3 Phase 1 5 2 0 48 AK R2 091P500 2 2 3 0 32 AK R2 047P500 3 7 5 0 19 AK R2 047P500 0 4 0 5 97 AK R2 360P500 0 75 1 0 97 AK R2 360P500 en 15 2 0 97 AK R2 360P500 2 2 3 0 97 AK R2 120P1K2 3 7 5 0 77 AK R2 120P1K2 Resistors listed in this table are rated 5 duty cycle 12 Allen Bradley AC Adjustable Frequency Drives Po
136. 6 2 63 43 55 5 74 11 15 7 5 10 B042A3AYNANCO D 54 63 84 62 1 72 4 96 6 15 20 11 15 BO54A3AYNANCO E 70 81 108 78 2 93 1 124 18 5 25 15 20 B070ASAYNANCO E Catalog code corresponds to output amps in these columns Drive must be programmed to lower voltage to obtain higher currents shown at right 380 480V ac Three Phase Drives IP20 NEMA Type Output Amps Nominal Power Ratings 1 with HIM 480V ac Input 380 400V ac Input Normal Duty Heavy Duty Cat No Cont 1 Min 3 Sec Cont 1 Min 3 Sec kw Hp kw Hp 20A Frame Size 1 1 1 2 1 6 1 8 1 4 1 9 0 37 0 5 0 25 0 33 D1P1A3AYNNNCO A 2 1 2 4 3 2 2 1 2 4 3 2 0 75 1 0 0 55 0 75 D2P1A3AYNNNCO A 3 4 4 5 6 0 3 5 4 5 6 0 1 5 2 0 1 1 1 5 D3P4A3AYNNNCO A 5 0 5 5 7 5 5 0 5 5 TS 2 2 3 0 15 2 0 D5POA3AYNNNCO B 8 0 8 8 12 8 7 9 9 13 2 4 0 5 0 3 0 3 0 D8POA3AYNNNCO B 11 12 1 16 5 11 5 13 17 4 5 5 15 4 0 5 0 D011A3AYNANCO C 14 16 5 22 15 4 17 2 23 1 7 5 10 5 5 7 5 D014A3AYNANCO C 22 24 2 33 22 24 2 33 11 15 TG 10 D022A3AYNANCO D 27 33 44 30 33 45 15 20 11 15 D027A3AYNANCO D 34 40 5 54 37 45 60 18 5 25 15 20 DO34A3AYNANCO D 40 51 68 43 56 74 22 30 18 5 25 DO40A3AYNANCO D 52 60 80 60 66 90 30 40 22 30 D052A3AYNANCO E 65 78 104 72 90 120 37 50 30 40 DO65A3AYNANCO E Catalog code corresponds to output amps in these columns Drive must be programmed to lower voltage to obtain higher currents shown at right 48 Allen B
137. 60 200 150 260 205 286 308 390 410 132 110 D248A0ENNANANE 6 261 205 287 308 410 410 200 150 261 205 287 308 410 410 132 110 D261A0ENNBNANE 9 300 245 1330 368 450 490 250 200 300 245 330 368 450 490 160 130 D300A0ENNBNANE 9 385 300 424 450 600 600 300 250 385 300 424 450 600 600 200 160 D385A0ENNBNANE 10 460 385 506 578 770 770 350 300 460 385 506 578 770 770 250 200 D460A0ENNBNANE 10 500 420 550 630 750 840 450 350 500 420 550 630 750 840 250 250 D500A0ENNBNANE 10 590 520 649 780 956 956 500 450 590 520 649 780 956 956 1315 250 D590A0ENNBNANE 11 650 590 715 885 ns 500 500 650 590 715 885 TEA 355 315 D650A0ENNBNANE 11 730 650 803 975 din 600 500 730 650 803 975 em 400 855 D730A0ENNBNANE 11 N 730 902 1095 ns 700 600 820 730 902 1095 toe 450 400 D820A0ENNBNANE 12 n 820 Hee aa 800 700 920 820 put hara 500 450 D920A0ENNBNANE 12 ose 920 E Aa 900 800 1030 920 AO EN 560 500 D1KOAOENNBNANE 12 Catalog number corresponds to output amps in this column Drive must be programmed to lower voltage to obtain higher currents shown at right These drives have dual current ratings one for normal duty applications and one for heavy duty in parenthesis The drive may be operated at either rating t 380 400V 85 A rating is limited to 45 C surrounding air 8 380 400V 205 A rating is limited to 40
138. 7 6 A 3 3 kW 5 0 Hp 3 Hand Off Auto Selector Keypad Code Description BEN E with Jog Function Volts per Hertz Sensorless f H H Vector Performance a OS J V Sensorless Vector Control and em onono an Option 2 ode escription Volts per Hertz E DB blank DB Brake Connector Fa 24V dc SB blank Source Brake Contactor g D 120V ac See Accessories for extended motor and SB Wx No cable source brake cable lengths B 240V ac k The output contactor is included with the Safety Monitor option SIBI s Code Description OC Output Contactor SM Safety Monitor Product Selection Only a sample of products are listed in the tables below Refer to the Catalog Number Explanation for complete product availability Allen Bradley Cat No Input 24V DC 120V AC 240V AC Voltage 3 Phase kW Rating 3 Phase Hp Rating Output Current Control Voltage Control Voltage Control Voltage 200 240v 0 4 0 5 2 3A 284D FHB2P3Z 10 CR 284D FHB2P3D 10 CR 284D FHB2P3B 10 CR 50 60 Hz 0 75 1 0 45A 284D FHB4P5Z 10 CR 284D FHB4P5D 10 CR 284D FHB4P5B 10 CR 3 Phase 1 5 2 0 7 6 A 284D FHB7P6Z 25 CR 284D FHB7P6D 25 CR 284D FHB7P6B 25 CR 0 4 0 5 14A 284D FHD1P4Z 10 CR 284D FHD1P4D 10 CR 284D FHD1P4B 10 CR 380 480v 0 75 1 0 2 3A 284D FHD2P3Z 10 CR 284D FHD2P3D 10 CR 284D FHD2P3B 10 CR 50 60 Hz 1 5 2 0 4 0A 284D FHD4P0Z 10 CR 284D FHD4POD 10 CR 284D FHD4P0B 10 CR 3 Phase 2 2
139. 7 9 5 5 7 5 4 0 5 0 BO22FOAYNANCO D 28 33 44 32 2 37 9 50 6 75 10 5 5 7 5 BO28FOAYNANCO D 42 46 2 63 43 55 5 74 11 15 7 5 10 B042FOAYNANCO D 54 63 84 62 1 72 4 96 6 15 20 11 15 BO54FOAYNANCO E 70 81 108 78 2 93 1 124 18 5 25 15 20 BO7OFOAYNANCO E Catalog code corresponds to output amps in these columns Drive must be programmed to lower voltage to obtain higher currents shown at right 380 480V ac Three Phase Drives Flange Type without Output Amps Nominal Power Ratings HIM 480V ac Inputx 380 400V ac Input Normal Duty Heavy Duty Cat No Frame Cont 1 Min 3 Sec Cont 1 Min 3 Sec kw Hp kw Hp 20A Size 1 1 1 2 1 6 1 3 1 4 1 9 0 37 05 0 25 0 33 D1P1FOAYNNNCO A 2 1 2 4 3 2 2A 2 4 3 2 0 75 1 0 0 55 0 75 D2P1FOAYNNNCO A 3 4 4 5 6 0 3 5 4 5 6 0 15 2 0 1 1 1 5 D3P4FOAYNNNCO A 5 0 5 5 7 5 5 0 5 5 7 5 2 2 3 0 1 5 2 0 D5POFOAYNNNCO B 8 0 8 8 12 8 7 9 9 13 2 4 0 5 0 3 0 3 0 D8POFOAYNNNCO B 11 12 1 16 5 11 5 13 17 4 5 5 TS 4 0 5 0 DO11FOAYNANCO C 14 16 5 22 15 4 17 2 23 1 7 5 10 5 5 7 5 DO14FOAYNANCO C 22 24 2 33 22 24 2 33 11 15 7 5 10 DO22FOAYNANCO D 27 33 44 30 33 45 15 20 11 15 DO27FOAYNANCO D 34 40 5 54 37 45 60 18 5 25 15 20 DO34FOAYNANCO D 40 51 68 43 56 74 22 30 18 5 25 DO40FOAYNANCO D 52 60 80 60 66 90 30 40 22 30 D052FOAYNANCO E 65 78 104 72 90 120 37 50 30 40 DO65FOAYNANCO E
140. 8 22 3 0 15 1 5 E3P9C3AYNNNCO B 6 1 6 7 9 1 4 0 5 0 3 0 3 0 E6PICSAYNNNCO B 9 0 9 9 13 5 5 5 7 5 4 0 5 0 E9POCZAYNNNCO D 11 13 5 18 7 5 10 55 7 5 E011C3AYNNNCO D 17 18 7 25 5 11 15 75 10 E017C3AYNNNCO D 22 25 5 34 15 20 11 15 E022C3AYNNNCO D 27 33 44 18 5 25 15 20 E027C3AYNNNCO D 32 40 5 54 22 30 18 5 25 E032C3AYNNNCO D 41 48 64 30 40 22 30 E041C3AYNANCO E 52 61 5 82 37 50 30 40 E052C3AYNANCO E 50 Allen Bradley AC Adjustable Frequency Drives PowerFlex 70 Standard Drives Selection Wall Machine Mount IP54 NEMA Type 12 Position d G 200 240V ac Three Phase Drives IP54 NEMA Type 12 Output Amps Nominal Power Ratings with HIM 240V ac Inputx 208V ac Input Normal Duty Heavy Duty Cat No Frame Cont 1 Min 3 Sec Cont 1 Min 3 Sec kW Hp kW Hp 20A Size 54 63 84 62 1 72 4 96 6 15 20 11 15 BO54G3AYNANCO E 70 81 108 78 2 93 1 124 18 5 25 15 20 BO70G3AYNANCO E Catalog code corresponds to output amps in these columns Drive must be programmed to lower voltage to obtain higher currents shown at right 380 480V ac Three Phase Drives IP54 NEMA Type 12 Output Amps Nominal Power Ratings with HIM 480V ac Inputx 380 400V ac Input Normal Duty Heavy Duty Cat No Frame Cont 1 Min 3 Sec Cont 1 Min 3 Sec kw Hp kw Hp 20A Size 52 60 80 60 66 90 30 40 22 30 D052G3AYNANCO E 65 78 104 72 90 120 37 50 30 40 D065G3A
141. 8 B 5 5 7 5 24 1321 3R25 B 1321 3RA25 B 7 5 10 33 1321 3R35 B 1321 3RA35 B 11 15 49 1321 3R45 B 1321 3RA45 B 15 20 65 1321 3R55 B 1321 3RA55 B 18 5 25 75 1321 3R80 B 1321 3RA80 B 22 30 90 1321 3R80 B 1321 3RA80 B 30 40 120 1321 3R100 B 1321 3RA100 B 37 50 145 1321 3R130 B 1321 3RA130 B 36 Allen Bradley AC Adjustable Frequency Drives PowerFlex 400 480V 60 Hz Three Phase PowerFlex 400 Ratings IPOO Open Style 1P11 NEMA Type 1 kW Hp Amps Cat No Cat No 3 Impedance 2 2 3 0 6 0 1321 3R8 C 1321 3RA8 C 4 0 5 0 10 5 1321 3R8 B 1321 3RA12 B 5 5 7 5 12 1321 3R12 B 1321 3RA12 B 1 5 10 AL 1321 3R18 B 1321 3RA18 B 11 15 22 1321 3R25 B 1321 3RA25 B 15 20 30 1321 3R35 B 1321 3RA35 B 18 5 25 38 1321 3R35 B 1321 3RA35 B 22 30 45 5 1321 3R45 B 1321 3RA45 B 30 40 60 1321 3R55 B 1321 3RA55 B 37 50 72 1321 3R80 B 1321 3RA80 B 45 60 88 1321 3R80 B 1321 3RA80 B 55 75 105 1321 3R100 B 1321 3RA100 B 75 100 142 1321 3R130 B 1321 3RA130 B 90 125 170 1321 3R160 B 1321 3RA160 B 110 150 208 1321 3R200 B 1321 3RA200 B 5 Impedance 2 2 3 0 6 0 1321 3R8 D 1321 3RA8 D 4 0 5 0 10 5 1321 3R8 C 1321 3RA12 B 5 5 7 5 12 1321 3R12 C 1321 3RA12 C 7 5 10 17 1321 3R18 C 1321 3RA18 C 11 15 22 1321 3R25 C 1321 3RA25 C 15 20 30 1321 3R35 C 1321 3RA35 C 18 5 25 38 1321 3R35 C 1321 3RA35 C 2
142. 80 Normal Duty 150 1321 3R200 C 1321 3RA200 C 1321 3R200 C 1321 3RA200 C 20BD248 Heavy Duty 150 1321 3R200 C 1321 3RA200 C 1321 3R200 C 1321 3RA200 C 20BD248 Normal Duty 200 1321 3RB250 C 1321 3RAB250 C 1321 3RB250 C 1321 3RAB250 C Input line reactors were sized based on the NEC fundamental motor amps Output line reactors were sized based on the VFD rated output currents 4 impedance Allen Bradley 87 AC Adjustable Frequency Drives PowerFlex 700 Input and Output Line Reactors 600V 60 Hz Three Phase 3 Impedance Input Line Reactor Output Line Reactor IPOO Open Style IP11 NEMA Type 1 IPOO Open Style IP11 NEMA Type 1 Drive Cat No Duty Hp Cat No Cat No Cat No Cat No 20BE1P7 Heavy Duty 0 5 1321 3R1 C 1321 3RA1 C 1321 3R2 B 1321 3RA2 B 20BE1P7 Normal Duty 1 1321 3R2 B 1321 3RA2 B 1321 3R2 B 1321 3RA2 B 20BE2P7 Heavy Duty 1 1321 3R2 B 1321 3RA2 B 1321 3R4 D 1321 3RA4 D 20BE2P7 Normal Duty 2 1321 3R4 D 1321 3RA4 D 1321 3R4 D 1321 3RA4 D 20BE3P9 Heavy Duty 2 1321 3R4 D 1321 3RA4 D 1321 3R4 C 1321 3RA4 C 20BE3P9 Normal Duty 3 1321 3R4 C 1321 3RA4 C 1321 3R4 C 1321 3RA4 C 20BE6P1 Heavy Duty 3 1321 3R4 C 1321 3RA4 C 1321 3R8 C 1321 3RA8 C 20BE6P1 Normal Duty 5 1321 3R8 C 1321 3RA8 C 1321 3R8 C 1321 3RA8 C 20BE9PO Heavy Duty 5 1321 3R8 C 1321 3RA8 C 1321 3R12 G 1321
143. 9 156 179 213 238 132 110 E144A0ENNANANE 6 170 144 187 216 245 245 150 150 170 144 187 216 245 245 160 132 E170A0ENNBNANE 9 208 170 38 230 250 1289 289 200 150 170 230 250 289 289 200 160 E208A0ENNBNANE 9 261 208 287 312 375 375 1250 200 261 208 287 312 375 375 250 200 E261A0ENNBNANE 10 325 261 358 392 470 470 350 250 325 261 358 392 470 470 315 250 E325A0ENNBNANE 10 385 325 424 488 585 585 400 350 385 325 424 488 585 585 355 315 E385A0ENNBNANE 10 416 325 458 488 585 585 450 350 416 325 458 488 585 585 400 315 E416A0ENNBNANE 10 460 385 506 578 693 693 450 400 460 385 506 578 693 693 450 355 E460A0ENNBNANE 11 502 460 4 552 690 828 828 500 450 502 460 552 690 828 828 500 450 E502A0ENNBNANE 11 590 502 649 753 904 904 600 500 590 502 649 753 904 904 560 500 E590A0ENNBNANE 11 650 590 4 715 885 eee 700 650 650 590 715 885 te 630 560 E650A0ENNBNANE 12 750 650 4 825 975 A170 800 700 750 650 825 975 ho 710 630 E750A0ENNBNANE 12 pe en 902 975 en 900 700 820 750 902 975 hare 800 630 E820A0ENNBNANE 12 Catalog number corresponds to output amps in this column Drive must be programmed to lower voltage to obtain higher currents shown at right These drives have dual current ratings one for normal duty applications and one for heavy duty applications in paren
144. A4 D 20DE3P9 Heavy Duty 2 1321 3R4 D 1321 3RA4 D 1321 3R4 D 1321 3RA4 D 20DE3P9 Normal Duty 3 1321 3R4 D 1321 3RA4 D 1321 3R4 D 1321 3RA4 D 20DE6P1 Heavy Duty 3 1321 3R4 D 1321 3RA4 D 1321 3R8 D 1321 3RA8 D 20DE6P1 Normal Duty 5 1321 3R8 D 1321 3RA8 D 1321 3R8 D 1321 3RA8 D 20DE9P0 Heavy Duty 5 1321 3R8 D 1321 3RA8 D 1321 3R12 Ct 1321 3RA12 C 20DE9P0 Normal Duty 7 5 1321 3R12 Ct 1321 3RA12 Ct 1321 3R12 Ct 1321 3RA12 C 20DE011 Heavy Duty 7 5 1321 3R12 Ct 1321 3RA12 Ct 1321 3R12 C 1321 3RA12 C 20DE011 Normal Duty 10 1321 3R12 C 1321 3RA12 C 1321 3R12 C 1321 3RA12 C 20DE017 Heavy Duty 10 1321 3R12 C 1321 3RA12 C 1321 3R18 C 1321 3RA18 C 20DE017 Normal Duty 15 1321 3R18 C 1321 3RA18 C 1321 3R18 C 1321 3RA18 C 20DE022 Heavy Duty 15 1321 3R18 C 1321 3RA18 C 1321 3R25 Ct 1321 3RA25 C 20DE022 Normal Duty 20 1321 3R25 C 1321 3RA25 C 1321 3R25 Ct 1321 3RA25 C 20DE027 Heavy Duty 20 1321 3R25 Ct 1321 3RA25 C 1321 3R35 Ct 1321 3RA35 C 20DE027 Normal Duty 25 1321 3R35 C 1321 3RA35 C 1321 3R35 Ct 1321 3RA35 C 20DE032 Heavy Duty 25 1321 3R35 Ct 1321 3RA35 C 1321 3R35 Ct 1321 3RA35 C 20DE032 Normal Duty 30 1321 3R35 Ct 1321 3RA35 C 1321 3R35 Ct 1321 3RA35 C 20DE041 Heavy Duty 30 1321 3R35 Ct 1321 3RA35 C 1321 3R45 C 1321 3RA45 C 20DE041 Normal Duty 40 1321 3R45 C 1321 3RA45 C 1321 3R45 C 1321 3RA45 C 20DE052 Heavy Duty 40 1321 3R45 C 1321 3RA45 C 1321 3R55 C 1321 3RA55 C 20DE052 Normal Duty 50 1321 3R55 C 1321 3RA55 C 1321 3R5
145. AC Adjustable Frequency Drives PowerFlex 40 Input Line Reactors 240V 50 60 Hz Three Phase 3 Impedance Maximum Fundamental Amps Continuous Amps Inductance Watts Loss kw Hp A A mh Ww Cat No 0 4 0 5 4 0 6 0 12 21 1321 3R4 B 0 75 1 0 8 0 12 3 0 29 1321 3R4 B 1 5 2 0 8 0 12 1 5 19 5 1321 3R8 B 2 8 3 0 12 18 1 25 26 1321 3R12 A 3 7 5 0 18 27 0 8 36 1321 3R18 A 5 5 75 25 37 5 0 5 48 1321 3R25 A 78 10 35 52 5 0 4 49 1321 3R35 A Catalog numbers listed are for 3 impedance open style units NEMA Type 1 and 5 impedance reactor types are also available Refer to publication 1321 TD001 Input Line Reactors 480V 50 60 Hz Three Phase 3 Impedance Maximum Fundamental Amps Continuous Amps Inductance Watts Loss kW Hp A A mh WwW Cat No 0 4 0 5 2 0 3 0 20 11 3 1321 3R2 B 0 75 1 0 4 0 6 0 9 0 20 1321 3R4 C 1 5 2 0 4 0 6 0 6 5 20 1321 3R4 B 2 2 3 0 8 0 12 5 0 25 3 1321 3R8 C 4 0 5 0 12 18 2 5 31 1321 3R8 B 5 5 7 5 12 18 2 5 31 1321 3R12 B 75 10 18 27 1 5 43 1321 3R18 B 11 15 25 37 5 12 52 1321 3R25 B Catalog numbers listed are for 3 impedance open style units NEMA Type 1 and 5 impedance reactor types are also available Refer to publication 1321 TDOO1 Input Line Reactors 600V 50 60 Hz Three Phase 3 Impedance Maximum Fundamental Amps Continuous Amps Inductance Watts Loss kW Hp A A mh Ww Cat No 0 75 1
146. Automation has registered facilities encompassing more than 45 separate sites around the world to the ISO 9001 standard This registration means that its quality system governing the design development manufacture and delivery of its products has been verified by third party audits Contacting Standards Organizations For contact information of organizations regarding standards that may impact the installation application and or interoperability of Allen Bradley branded products refer to the following on line address http www ab com en epub catalogs 12768 229240 229242 284 1186 tab12 html Specifying Enclosures Specify the Correct Enclosure for your Motor Controls Enclosure Selection Criteria Enclosures for Non Hazardous Locations ControlNet Conformance Products which have been determined by ControlNet International to have passed conformance testing receive a Declaration of Conformity from ControlNet International for the product Vendors who have received a Declaration of Conformity for a product have the right to be use the ControlNet CONFORMANCE TESTED certification logo mark and certification word mark on the product and in materials about the product DeviceNet Conformance The Conformance Tested Service Mark is an ODVA controlled logo protected by law the authorized use of which indicates that a product has passed conformance testing at an official ODVA Test Service Provider TSP The DeviceNet conformance tested
147. B028 Heavy Duty 7 5 1321 3R25 B 1321 3RA25 B 1321 3R35 B 1321 3RA35 B 20DB028 Normal Duty 10 1321 3R35 B 1321 3RA35 B 1321 3R35 B 1321 3RA35 B 20DB042 Heavy Duty 10 1321 3R35 B 1321 3RA35 B 1321 3R45 B 1321 3RA45 B 20DB042 Normal Duty 15 1321 3R45 B 1321 3RA45 B 1321 3R45 B 1321 3RA45 B 20DB052 Heavy Duty 15 1321 3R45 B 1321 3RA45 B 1321 3R55 B 1321 3RA55 B 20DB052 Normal Duty 20 1321 3R55 B 1321 3RA55 B 1321 3R55 B 1321 3RA55 B 20DB070 Heavy Duty 20 1321 3R55 B 1321 3RA55 B 1321 3R80 B 1321 3RA80 B 20DB070 Normal Duty 25 1321 3R80 B 1321 3RA80 B 1321 3R80 B 1321 3RA80 B 20DB080 Heavy Duty 25 1321 3R80 B 1321 3RA80 B 1321 3R80 B 1321 3RA80 B 20DB080 Normal Duty 30 1321 3R80 B 1321 3RA80 B 1321 3R80 B 1321 3RA80 B 20DB104 Heavy Duty 30 1321 3R80 B 1321 3RA80 B 1321 3R80 B 1321 3RA80 B 20DB104 Normal Duty 40 1321 3R100 B 1321 3RA100 B 1321 3R100 B 1321 3RA100 B 20DB130 Heavy Duty 40 1321 3R100 B 1321 3RA100 B 1321 3R100 B 1321 3RA100 B 20DB130 Normal Duty 50 1321 3R130 B 1321 3RA130 B 1321 3R130 B 1321 3RA130 B 20DB154 Heavy Duty 50 1321 3R130 B 1321 3RA130 B 1321 3R130 B 1321 3RA130 B 20DB154 Normal Duty 60 1321 3R160 B 1321 3RA160 B 1321 3R160 B 1321 3RA160 B 20DB192 Heavy Duty 60 1321 3R160 B 1321 3RA160 B 1321 3R160 B 1321 3RA160 B 20DB192 Normal Duty 75 1321 3R200 B 1321 3RA200 B 1321 3R200 B 1321 3RA200 B 20DB260 Heavy Duty 75 1321 3R200 B 1321 3RA200 B 1321 3R200 B 1321 3RA200 B 20DB260 Normal Duty 100 1321 3RB25
148. C 90 125 1321 3TH145 BB 1321 3TH145 CC 110 150 1321 3TH175 BB 1321 3TH175 CC 149 200 1321 3TH220 BB 136 Allen Bradley AC Adjustable Frequency Drives PowerFlex 700S Input and Output Line Reactors 240V 60 Hz Three Phase 3 Impedance Input Line Reactor Output Line Reactor IPOO Open Style IP11 NEMA Type 1 IPOO Open Style 1P11 NEMA Type 1 O Duty Hp Cat No Cat No Cat No Cat No 20DB2P2 Heavy Duty 0 33 1321 3R2 D 1321 3RA2 D 1321 3R2 D 1321 3RA2 D 20DB2P2 Normal Duty 0 5 1321 3R2 D 1321 3RA2 D 1321 3R2 D 1321 3RA2 D 20DB4P2 Heavy Duty 0 75 1321 3R4 A 1321 3RA4 A 1321 3R4 A 1321 3RA4 A 20DB4P2 Normal Duty 1 1321 3R4 A 1321 3RA4 A 1321 3R4 A 1321 3RA4 A 20DB6P8 Heavy Duty 1 5 1321 3R8 B 1321 3RA8 B 1321 3R8 A 1321 3RA8 A 20DB6P8 Normal Duty 2 1321 3R8 A 1321 3RA8 A 1321 3R8 A 1321 3RA8 A 20DB9P6 Heavy Duty 2 1321 3R8 A 1321 3RA8 A 1321 3R12 A 1321 3RA12 A 20DB9P6 Normal Duty 3 1321 3R12 A 1321 3RA12 A 1321 3R12 A 1321 3RA12 A 20DB015 Heavy Duty 3 1321 3R12 A 1321 3RA12 A 1321 3R18 A 1321 3RA18 A 20DB015 Normal Duty 5 1321 3R18 A 1321 3RA18 A 1321 3R18 A 1321 3RA18 A 20DB022 Heavy Duty 5 1321 3R18 A 1321 3RA18 A 1321 3R25 A 1321 3RA25 A 20DB022 Normal Duty 7 5 1321 3R25 A 1321 3RA25 A 1321 3R25 A 1321 3RA25 A 20DB028 Heavy Duty 7 5 1321 3R25 A 1321
149. C5 HO H1 H2 H3 H5 H5 C3 C5 HO H1 H2 H3 H4 JC AA1 JF AA1 JM AA1 JR AA1 JT AA1 KD AA1 KM JF AA1 BA BM1 BM2 LQH AA1 BM1 LRH LRN LQN AA1 BM2 LRH LRN LRH AA1 BM1 LQH LQN LRN AA1 BM2 LQH LQN ME JR AA1 MH JR AA1 N1 AA1 N2 AA1 N3 AA1 NP CB DS FB PR1 AA1 PR2 AA1 Can not be used with specific AF or AH options 74 Allen Bradley AC Adjustable Frequency Drives PowerFlex 700 Contents Standard Packaged Description Product Product Conformity to Standards this page this page Description this page page 91 Catalog Number Explanation page 76 page 92 Quick Ship Program page 94 Product Selection page 78 page 95 User Installed Options page 81 m Factory Installed Options page 90 page 96 Conformity to Standards The PowerFlex 700 conforms to the following Standard Packaged Conformity to Product Product UL Listed CSA Certified c UL IEC Designed to Meet CE Approved C Tick See page 100 KATAL AJ Allen Bradley PowerFlex 700 AC Drive Drive Description The PowerFlex 700 AC drive offers a flexible package of power control and operator interface to meet the demands for space flexibility and performance The many features allow the user to easily configure the drive for most application needs including TorqProve which automates torque and brake proving thereby simplif
150. CL 7 5 10 22 RF015 CL 11 15 22 RF024 CL This filter is suitable for use with a cable length of up to 10 meters for Class A and 1 meter for Class B environments Drives are available in these ratings with internal S Type filters Filter must be Series B or later This filter is suitable for use with a cable length of up to 100 meters for Class A and 5 meters for Class B environments 20 Allen Bradley AC Adjustable Frequency Drives PowerFlex 40 Packaged Drives Programs Overview The PowerFlex 40 Packaged Drives Program allows users to create drive packages based on their specific needs This program enhances stand alone drive functionality through additional control power and packaging options which are ideal for OEM and end users with special installation needs The program has two levels Standard Packaged Drives The Standard Packaged Drives Program allows users to create drive packages based on their specific needs A complete drive package may be specified by assembling a single catalog number string that includes a base drive and all required options Packaging is available for 480V requirements in NEMA Type 4 12 IP66 and NEMA Type 4X IP66 The program consists of a fully defined catalog string identified within this price sheet Focused on higher volume repeat business the standard designs provide consistent manufacturing and minimizes customer resources by reducing engineering manufacturing a
151. D 22 25 5 34 15 20 11 15 E022A0AYNNNCO D 27 33 44 18 5 25 15 20 E027A0AYNNNCO D 32 40 5 54 22 30 18 5 25 E032A0AYNNNCO D 41 48 64 30 40 22 30 E041 A0AYNANCO E 52 61 5 82 37 50 30 40 E052A0AYNANCO E Allen Bradley 49 AC Adjustable Frequency Drives PowerFlex 70 Standard Drives Selection Wall Machine Mount IP66 NEMA Type 4X 12 For Indoor Use Position d C 200 240V ac Three Phase Drives IP66 NEMA Type Output Amps Nominal Power Ratings 4X 12 with HIM 240V ac Inputx 208V ac Input Normal Duty Heavy Duty Cat No Frame Cont 1 Min 3 Sec Cont 1 Min 3 Sec kw Hp kw Hp 20A Size 2 2 2 4 3 3 2 5 2 3 7 0 37 0 5 0 25 0 33 B2P2C3AYNNNCO B 4 2 4 8 6 4 4 8 5 5 7 4 0 75 1 0 0 55 0 75 B4P2C3AYNNNCO B 6 8 9 0 12 7 8 10 3 13 8 1 5 2 0 1 1 1 5 B6P8C3AYNNNCO B 9 6 10 6 14 4 11 12 1 16 5 2 2 3 0 1 5 2 0 B9P6C3AYNNNCO B 15 3 17 4 23 2 17 5 19 2 26 2 4 0 5 0 3 0 3 0 B015C3AYNANCO D 22 24 2 33 25 3 27 8 37 9 5 5 1 5 4 0 5 0 BO22C3AYNANCO D 28 33 44 32 2 37 9 50 6 75 10 5 5 75 BO28C3AYNANCO D 42 46 2 63 43 55 5 74 11 15 7 5 10 B042C3AYNANCO D 54 63 84 62 1 72 4 96 6 15 20 11 15 B054C3AYNANCO E 70 81 108 78 2 93 1 124 18 5 25 15 20 BO70C3AYNANCO E Catalog code corresponds to output amps in these columns Drive must be programmed to lower voltage to obtain higher currents shown at right 380 480V ac Three Phase Drives
152. D014 Normal Duty 10 1321 3R18 C 1321 3RA18 C 1321 3R18 C 1321 3RA18 C 20AD022 Heavy Duty 10 1321 3R18 C 1321 3RA18 C 1321 3R25 C 1321 3RA25 C 20AD022 Normal Duty 15 1321 3R25 C 1321 3RA25 C 1321 3R25 C 1321 3RA25 C 20AD027 Heavy Duty 15 1321 3R25 C 1321 3RA25 C 1321 3R25 C 1321 3RA25 C 20AD027 Normal Duty 20 1321 3R35 CH 1321 3RA35 C 1321 3R25 C 1321 3RA25 C 20AD034 Heavy Duty 20 1321 3R35 Ct 1321 3RA35 C 1321 3R35 C 1321 3RA35 C 20AD034 Normal Duty 25 1321 3R35 C 1321 3RA35 C 1321 3R35 C 1321 3RA35 C 20AD040 Heavy Duty 25 1321 3R35 C 1321 3RA35 C 1321 3R45 C 1321 3RA45 C 20AD040 Normal Duty 30 1321 3R45 C 1321 3RA45 C 1321 3R45 C 1321 3RA45 C 20AD052 Heavy Duty 30 1321 3R45 C 1321 3RA45 C 1321 3R55 C 1321 3RA55 C 20AD052 Normal Duty 40 1321 3R55 C 1321 3RA55 C 1321 3R55 C 1321 3RA55 C 20AD065 Heavy Duty 40 1321 3R55 C 1321 3RA55 C 1321 3R80 C 1321 3RA80 C 20AD065 Normal Duty 50 1321 3R80 C 1321 3RA80 C 1321 3R80 C 1321 3RA80 C Input line reactors were sized based on the NEC fundamental motor amps Output line reactors were sized based on the VFD rated output currents Reactors sized at 4 impedance 58 Allen Bradley AC Adjustable Frequency Drives PowerFlex 70 Input and Output Line Reactors 600V 60 Hz Three Phase 3 Impedance Input Line Reactor Output Line Reactor IPOO Open Style IP11 NEMA Type 1 IPOO Open Style IP11 NEMA Type 1
153. DWG E FP Black amp Whites Isolation Transformers NEMA 3R Standalone 1301 APPDWG FP 208V 60 Hz Three Phase Primary 460V 60 Hz Three Phase Primary 575V 60 Hz Three Phase Primary amp Secondary amp Secondary amp Secondary IP32 NEMA Type 3R IP32 NEMA Type 3R IP32 NEMA Type 3R Drive Cat No Motor Rating kW Hp Cat No Cat No Cat No 21VD2P1 0 75 1 0 1321 3TW005 XX 1321 3TW005 BB 21VD3P4 1 5 2 0 1321 3TW005 XX 1321 3TW005 BB 21VD5P0 12 2 3 0 1321 3TW005 XX 1321 3TW005 BB 1321 3TW005 CC 21VD8PO 4 0 5 0 1321 3TW007 XX 1321 3TW007 BB 1321 3TW007 CC 21VD011 5 5 7 5 1321 3TW011 XX 1321 3TW011 BB 1321 3TW011 CC 21VD014 7 5 10 1321 3TW014 XX 1321 3TW014 BB 1321 3TW014 CC 21VD022 11 15 1321 3TW020 XX 1321 3TW020 BB 1321 3TW020 CC 21VD027 15 20 1321 3TW027 BB 1321 3TW027 CC 21WD034 18 5 25 1321 3TW034 BB 1321 3TW034 CC 21WD040 22 30 1321 3TW040 BB 1321 3TW040 CC 21WD052 30 40 1321 3TW051 BB 1321 3TW051 CC 21WD065 37 50 1321 3TH063 BB 1321 3TH063 CC 21WD077 50 60 1321 3TH075 BB 1821 3TH075 CC 21WD095 55 75 1321 3TH093 BB 1321 3TH093 CC 21WD052 75 100 1321 3TH118 BB 1321 3TH118 CC 21WD156 90 125 1321 3TH145 BB 1321 3TH145 CC 21WD180 110 150 1321 3TH175 BB 1321 3TH175 CC 21WD248 132 200 1321 3TH220 BB PowerFlex 700 options only amp amp 5 Allen Bradley
154. M A2 No HIM Blank Plate 20 HIM AO LCD Full Numeric 20 HIM A3 DPI NEMA 1 WIM 20 WIM N1 LCD Programmer Only 20 HIM A5 Remote Panel Mount Full Numeric 20 HIM C3S Remote Panel Mount Full Numeric 20 HIM C3 Human Interface and Wireless Interface Modules cont Remote Panel Mount Programmer Only 20 HIM C5 Remote Panel Handheld Local Mount IP66 UL Drive Mount Type 4x 12 Description Cat No Cat No No HIM Blank Plate 20 HIM AO LCD Display Digital Speed 20 HIM A2 i 20 HIM C3 LCD Display Full Numeric Keypad 20 HIM A3 20 HIM C3S 3 20 HIM C5 LCD Display Programmer Only 20 HIM A5 20 HIM C5S DPI NEMA 1 WIM 20 WIM N1 DPI NEMA 4 WIM 20 WIM N4S For indoor use only Includes a PowerFlex HIM Interface Cable 20 HIM H10 Includes a 1202 C30 interface cable 3 meters for connection to drive Human Interface Module Accessories Description Cat No Bezel Kit for LCD HIMs NEMA 1 20 HIM B1 PowerFlex HIM Interface Cable 1 m 39 in 20 HIM H10 Cable Kit Male Female gt 0 33 Meters 1 1 Feet 1202 H03 1 Meter 3 3 Feet 1202 H10 3 Meter 9 8 Feet 1202 H30 9 Meter 29 5 Feet 1202 H90 DPI SCANport One to Two Port Splitter Cable 1203 S03 t Includes a 1202 C30 interface cable 3 meters for connection to drive Required only when HIM is used as handheld or remote g
155. M C5 20 HIM C5S 20 WIM N4S Handheld Local Drive Remote Panel Mount Mount IP66 UL Type 4x 12 Description Cat No Cat No Blank Plate 20 HIM AO LCD Display Digital Speed 20 HIM A2 i 20 HIM C3 LCD Display Full Numeric Keypad 20 HIM A3 20 HIM C3S F 20 HIM C5 LCD Display Programmer Only 20 HIM A5 20 HIM C5S DPI NEMA 1 WIM 20 WIM N1 DPI NEMA 4 WIM 20 WIM N4S For indoor use only Includes a PowerFlex HIM Interface Cable 20 HIM H10 t Includes a 1202 C30 cable 3 meters 134 Allen Bradley AC Adjustable Frequency Drives PowerFlex 700S Human Interface Module Accessories Description Cat No Bezel Kit for LCD HIMs NEMA 1 8 20 HIM B1 PowerFlex HIM Interface Cable 1 m 39 in 20 HIM H10 Cable Kit Male Female gt 0 33 Meters 1 1 Feet 1202 H03 1 Meter 3 3 Feet 1202 H10 3 Meter 9 8 Feet 1202 H30 9 Meter 29 5 Feet 1202 H90 DPI SCANport One to Two Port Splitter Cable 1203 S03 8 Includes an interface cable 1202 C30 for connection to drive Required only when HIM is used as handheld or remote gt Required in addition to 20 HIM H10 for distances up to a total maximum of 10 Meters 32 8 Feet Communication Option Kits Description Cat No ControlNet Coax Communication Adapter DPI 20 COMM C DeviceNet Communication Adapter DPI 20 COMM D EtherNet IP Communication Adapter DPI 20 COMM E Inte
156. NNCANN 11 15 21 C 23C D022A103NNCANN 15 20 27 C 23C D030A103NNCANN 18 5 25 34 D 23C D038A103NNCANN 22 30 40 D 23C D045A103NNCANN 30 40 52 D 23C D060A103NNCANN 37 50 65 E 23C D072A103NNCANN 45 60 77 E 23C D088A103NNCANN 55 75 96 E 23C D105A103NNCANN 75 100 124 E 23C D142A103NNCANN 42 Allen Bradley AC Adjustable Frequency Drives PowerFlex 400 Packaged Drives Programs Factory Installed Options Version Communication Description Cat Code RS485 3 DeviceNet D EtherNet IP E PROFIBUS DP P Drawing Options Engineered Drives Program Only Description One Set of Cat No Manufacturing Drawings 279 x 432 mm 11 x 17 in One set of schematics Information Only Manufacture Proceeding Not to be used as Approval Drawings Diskette 1301 MFDISK FP Electronic Drawings 1301 MFDWG E FP Black amp Whites 1301 MFDWG FP Final Drawings as shipped 279 x 432 mm 11 x 17 in One set of schematics Copy of Drawings that Shipped with the Job Diskette 1301 FINDISK FP Electronic Drawings 1301 FINDWG E FP Black amp Whites 1301 FINDWG FP Approval Drawings 279 x 432 mm 11 x 17 in One set of schematics Manufacture Held Until Approved Prints are Received Diskette 1301 APPDISK FP Electronic Drawings 1301 APPDWG E FP Black amp Whites 1301 APPDWG FP Allen Bradley 43 AC Adjustable Frequency Drives PowerFlex 400 Notes 44 Allen Brad
157. Normal Duty 5 1321 3R8 D 1321 3RA8 D 1321 3R8 D 1321 3RA8 D 20BE9PO Heavy Duty 5 1321 3R8 D 1321 3RA8 D 1321 3R12 Ct 1321 3RA12 Ct 20BE9PO Normal Duty 7 5 1321 3R12 Ct 1321 3RA12 C 1321 3R12 Ct 1321 3RA12 Ct 20BE011 Heavy Duty 7 5 1321 3R12 Ct 1321 3RA12 C 1321 3R12 G 1321 3RA12 C 20BE011 Normal Duty 10 1321 3R12 C 1321 3RA12 C 1321 3R12 C 1321 3RA12 C 20BE017 Heavy Duty 10 1321 3R12 C 1321 3RA12 C 1321 3R18 C 1321 3RA18 C 20BE017 Normal Duty 15 1321 3R18 C 1321 3RA18 C 1321 3R18 C 1321 3RA18 C 20BE022 Heavy Duty 15 1321 3R18 C 1321 3RA18 C 1321 3R25 Ct 1321 3RA25 C 20BE022 Normal Duty 20 1321 3R25 Ct 1321 3RA25 C 1321 3R25 Ct 1321 3RA25 C 20BE027 Heavy Duty 20 1321 3R25 Ct 1321 3RA25 C 1321 3R35 Ct 1321 3RA35 C 20BE027 Normal Duty 25 1321 3R35 Ct 1321 3RA35 C 1321 3R35 Ct 1321 3RA35 C 20BE032 Heavy Duty 25 1321 3R35 Ct 1321 3RA35 C 1321 3R35 Ct 1321 3RA35 C 20BE032 Normal Duty 30 1321 3R35 Ct 1321 3RA35 C 1321 3R35 Ct 1321 3RA35 C 20BE041 Heavy Duty 30 1321 3R35 Ct 1321 3RA35 C 1321 3R45 C 1321 3RA45 C 20BE041 Normal Duty 40 1321 3R45 C 1321 3RA45 C 1321 3R45 C 1321 3RA45 C 20BE052 Heavy Duty 40 1321 3R45 C 1321 3RA45 C 1321 3R55 C 1321 3RA55 C 20BE052 Normal Duty 50 1321 3R55 C 1321 3RA55 C 1321 3R55 C 1321 3RA55 C 20BE062 Heavy Duty 50 1321 3R55 C 1321 3RA55 C 1321 3R80 C 1321 3RA80 C 20BE062 Normal Duty 60 1321 3R80 C 1321 3RA80 C 1321 3R80 C 1321 3RA80 C 20BE077 Heavy Duty 60 1321 3R80 C 1321 3RA80 C 1321 3R80 C 1321 3RA80 C 20BE077 Norm
158. OMM External DPI I O Option Board IO OPT1 Compact I O Module 3 Channel 1769 SM1 Serial Null Modem Adapter 1203 SNM Smart Self powered Serial Converter RS 232 includes 1203 SSS 1203 SFC and 1202 C10 Cables For use only with External DP Communications Kits 20 XCOMM DC BASE Only ModBus RTU can be used with Vector Control Can only be used with Standard Control Internal Dynamic Brake Resistor Kits These resistors have a limited duty cycle Refer to the PowerFlex Dynamic Braking Selection Guide to determine if an internal resistor will be sufficient for your application An external resistor may be required Drive Input Brake Resistance Voltage Q Frame Cat No 62 0 20BB DB1 0 62 1 2 5 Hp 20BB DB1 1 208 240V ac 22 1 7 5 Hp 20BB DB2 1 22 2 20BB DB1 2 115 0 20BD DB1 0 380 480V ac 115 1 20BD DB1 1 68 2 20BD DB1 2 82 Allen Bradley AC Adjustable Frequency Drives PowerFlex 700 Isolation Transformers Motor Rating kW Hp 240V 60 Hz Three Phase 240V Primary 8 240V Secondary 460V 60 Hz Three Phase 460V Primary 8 460V Secondary 575V 60 Hz Three Phase 575V Primary 8 575V Secondary IP32 NEMA Type 3R IP32 NEMA Type 3R IP32 NEMA Type 3R Cat No Cat No Cat No 0 25 0 33 1321 3TW005 AA 1321 3TW005 BB 0 37 0 5 1321 3TW005 AA 1321 3TW005 BB
159. PowerFlex 700 Input and Output Line Reactors 480V 60 Hz Three Phase 5 Impedance Input Line Reactor Output Line Reactor IPOO Open Style IP11 NEMA Type 1 IPOO Open Style IP11 NEMA Type 1 Drive Cat No Duty Hp Cat No Cat No Cat No Cat No 20BD1P1 Heavy Duty 0 33 1321 3R1 B 1321 3RA1 B 1321 3R2 C 1321 3RA2 C 20BD1P1 Normal Duty 0 5 1321 3R1 B 1321 3RA1 B 1321 3R2 C 1321 3RA2 C 20BD2P1 Heavy Duty 0 75 1321 3R2 C 1321 3RA2 C 1321 3R2 B 1321 3RA2 B 20BD2P1 Normal Duty 1 1321 3R2 B 1321 3RA2 B 1321 3R2 B 1321 3RA2 B 20BD3P4 Heavy Duty 15 1321 3R4 D 1321 3RA4 D 1321 3R4 D 1321 3RA4 D 20BD3P4 Normal Duty 2 1321 3R4 D 1321 3RA4 D 1321 3R4 D 1321 3RA4 D 20BD5PO Heavy Duty 2 1321 3R4 D 1321 3RA4 D 1321 3R8 D 1321 3RA8 D 20BD5PO Normal Duty 3 1321 3R8 D 1321 3RA8 D 1321 3R8 D 1321 3RA8 D 20BD8PO Heavy Duty 3 1321 3R8 D 1321 3RA8 D 1321 3R8 C 1321 3RA8 C 20BD8PO Normal Duty 5 1321 3R8 C 1321 3RA8 C 1321 3R8 C 1321 3RA8 C 20BD011 Heavy Duty 5 1321 3R8 C 1321 3RA8 C 1321 3R12 C 1321 3RA12 C 20BD011 Normal Duty 7 5 1321 3R12 C 1321 3RA12 C 1321 3R12 C 1321 3RA12 C 20BD014 Heavy Duty 7 5 1321 3R12 C 1321 3RA12 C 1321 3R18 C 1321 3RA18 C 20BD014 Normal Duty 10 1321 3R18 C 1321 3RA18 C 1321 3R18 C 1321 3RA18 C 20BD022 Heavy Duty 10 1321 3R18 C 1321 3RA18 C 1321 3R25 C 1321 3RA25 C 20BD022
160. R18 A Catalog numbers listed are for 3 impedance open style units NEMA Type 1 and 5 impedance reactor types are also available Refer to publication 1321 TDOO1 Input Line Reactors 480V 50 60 Hz Three Phase 3 Impedance Maximum Fundamental Amps Continuous Amps Inductance Watts Loss kW Hp A A mh Ww Cat No 0 4 0 5 2 0 3 0 20 11 3 1321 3R2 B 0 75 1 0 4 0 6 0 9 0 20 1321 3R4 C 1 5 2 0 4 0 6 0 6 5 20 1321 3R4 B 2 2 3 0 8 0 12 5 0 25 3 1321 3R8 C 3 7 5 0 8 0 12 3 0 29 1321 3R8 B Catalog numbers listed are for 3 impedance open style units NEMA Type 1 and 5 impedance reactor types are also available Refer to publication 1321 TDOO1 EMC Filters Drive Ratings S Type Filter L Type Filter Input Voltage kW Hp Cat No Cat No t 0 2 0 25 22 RF010 AL 120V 50 60 Hz 0 4 0 5 22 RF010 AL 1 Phase 0 75 1 0 22 RF018 BL 1 1 15 22 RF025 CL 0 2 0 25 22 RF010 AL 240V 50 60 Hz 0 4 0 5 22 RF010 AL 1 Phase 0 75 1 0 E 22 RF010 AL 1 5 2 0 22 RF018 BL 0 2 0 25 22 RFO10 AL 240V 50 60 Hz 0 4 0 5 22 RF010 AL 1 Phase 0 75 1 0 22 RF010 AL NO BRAKE 1 5 2 0 22 RF018 BL 2 2 3 0 22 RF025 CL 0 2 0 25 22 RF9P5 AS 22 RF9P5 AL 0 4 0 5 22 RF9P5 AS 22 RF9P5 AL 240V 50 60 Hz 0 75 1 0 22 RF9P5 AS 22 RF9P5 AL 3 Phase 15 2 0 22 RF9P5 AS 22 RF9P5 AL 2 2 3 0 22 RF021 BS 22 RF021 BL 3 7 5 0 22 RF021 BS 22 RF021 BL 0 4 0 5 22 RF5P7 AS 22 RF5P7 AL 0 75 1 0 22 RF
161. RA12 B 1321 3R12 B 1321 3RA12 B 20DD014 Heavy Duty 7 5 1321 3R12 B 1321 3RA12 B 1321 3R18 B 1321 3RA18 B 20DD014 Normal Duty 10 1321 3R18 B 1321 3RA18 B 1321 3R18 B 1321 3RA18 B 20DD022 Heavy Duty 10 1321 3R18 B 1321 3RA18 B 1321 3R25 B 1321 3RA25 B 20DD022 Normal Duty 15 1321 3R25 B 1321 3RA25 B 1321 3R25 B 1321 3RA25 B 20DD027 Heavy Duty 15 1321 3R25 B 1321 3RA25 B 1321 3R25 B 1321 3RA25 B 20DD027 Normal Duty 20 1321 3R35 B 1321 3RA35 B 1321 3R25 B 1321 3RA25 B 20DD034 Heavy Duty 20 1321 3R35 B 1321 3RA35 B 1321 3R35 B 1321 3RA35 B 20DD034 Normal Duty 25 1321 3R35 B 1321 3RA35 B 1321 3R35 B 1321 3RA35 B 20DD040 Heavy Duty 25 1321 3R35 B 1321 3RA35 B 1321 3R45 B 1321 3RA45 B 20DD040 Normal Duty 30 1321 3R45 B 1321 3RA45 B 1321 3R45 B 1321 3RA45 B 20DD052 Heavy Duty 30 1321 3R45 B 1321 3RA45 B 1321 3R55 B 1321 3RA55 B 20DD052 Normal Duty 40 1321 3R55 B 1321 3RA55 B 1321 3R55 B 1321 3RA55 B 20DD065 Heavy Duty 40 1321 3R55 B 1321 3RA55 B 1321 3R80 B 1321 3RA80 B 20DD065 Normal Duty 50 1321 3R80 B 1321 3RA80 B 1321 3R80 B 1321 3RA80 B 20DD077 Heavy Duty 50 1321 3R80 B 1321 3RA80 B 1321 3R80 B 1321 3RA80 B 20DD077 Normal Duty 60 1321 3R80 B 1321 3RA80 B 1321 3R80 B 1321 3RA80 B 20DD096 Heavy Duty 60 1321 3R80 B 1321 3RA80 B 1321 3R80 B 1321 3RA80 B 20DD096 Normal Duty 75 1321 3R100 B 1321 3RA100 B 1321 3R100 B 1321 3RA100 B 20DD125 Heavy Duty 75 1321 3R100 B 1321 3RA100 B 1321 3R100 B 1321 3RA100 B 20DD125 Normal Duty 10
162. RA200 B 1321 3R200 B 1321 3RA200 B 132 200 248 1321 3RB250 B 1321 3RAB250 B 1321 3RB250 B 1321 3RAB250 B 5 Impedance 0 75 1 0 2 1 1321 3R2 B 1321 3RA2 B 1321 3R2 B 1321 3RA2 B 1 5 2 0 3 4 1321 3R4 D 1321 3RA4 D 1321 3R4 D 1321 3RA4 D 2 2 3 0 5 0 1321 3R8 D 1321 3RA8 D 1321 3R8 D 1321 3RA8 D 4 0 5 0 8 0 1321 3R8 C 1321 3RA8 C 1321 3R8 C 1321 3RA8 C 5 5 7 8 11 1321 3R12 C 1321 3RA12 C 1321 3R12 C 1321 3RA12 C 1 5 10 14 1321 3R18 C 1321 3RA18 C 1321 3R18 C 1321 3RA18 C 11 15 22 1321 3R25 C 1321 3RA25 C 1321 3R25 C 1321 3RA25 C 15 20 27 1321 3R35 Ct 1321 3RA35 C 1321 3R25 C 1321 3RA25 C 18 5 25 34 1321 3R35 C 1321 3RA35 C 1321 3R35 C 1321 3RA35 C 22 30 40 1321 3R45 C 1321 3RA45 C 1321 3R45 C 1321 3RA45 C 30 40 52 1321 3R55 C 1321 3RA55 C 1321 3R55 C 1321 3RA55 C 37 50 65 1321 3R80 C 1321 3RA80 C 1321 3R80 C 1321 3RA80 C 45 60 77 1321 3R80 C 1321 3RA80 C 1321 3R80 C 1321 3RA80 C 55 75 96 1321 3R100 C 1321 3RA100 C 1321 3R100 C 1321 3RA100 C 75 100 125 1321 3R130 C 1321 3RA130 C 1321 3R130 C 1321 3RA130 C 90 125 156 1321 3R160 C 1321 3RA160 C 1321 3R160 C 1321 3RA160 C 110 150 180 1321 3R200 C 1321 3RA200 C 1321 3R200 C 1321 3RA200 C 132 200 248 1321 3RB250 C 1321 3RAB250 C 1321 3RB250 C 1321 3RAB250 C Input line reactors were sized based on the NEC fundamental motor amps Output line reactors were sized based on the VFD rating output currents 4 impedance reactor Allen Bradley 113 AC Adjustable Frequency Drives PowerFlex D
163. RAB250 A Input line reactors were sized based on the NEC fundamental motor amps Output line reactors were sized based on the VFD rated output currents Allen Bradley 137 AC Adjustable Frequency Drives PowerFlex 700S Input and Output Line Reactors 240V 60 Hz Three Phase 5 Impedance Input Line Reactor Output Line Reactor Drive IPOO Open Style IP11 NEMA Type 1 IPOO Open Style IP11 NEMA Type 1 Cat No Duty Hp Cat No Cat No Cat No Cat No 20DB2P2 Heavy Duty 0 33 1321 3R2 A 1321 3RA2 A 1321 3R2 A 1321 3RA2 A 20DB2P2 Normal Duty 0 5 1321 3R2 A 1321 3RA2 A 1321 3R2 A 1321 3RA2 A 20DB4P2 Heavy Duty 0 75 1321 3R4 B 1321 3RA4 B 1321 3R4 B 1321 3RA4 B 20DB4P2 Normal Duty 1 1321 3R4 B 1321 3RA4 B 1321 3R4 B 1321 3RA4 B 20DB6P8 Heavy Duty 1 5 1321 3R8 B 1321 3RA8 B 1321 3R8 B 1321 3RA8 B 20DB6P8 Normal Duty 2 1321 3R8 B 1321 3RA8 B 1321 3R8 B 1321 3RA8 B 20DB9P6 Heavy Duty 2 1321 3R8 B 1321 3RA8 B 1321 3R12 B 1321 3RA12 B 20DB9P6 Normal Duty 3 1321 3R12 B 1321 3RA12 B 1321 3R12 B 1321 3RA12 B 20DB015 Heavy Duty 3 1321 3R12 B 1321 3RA12 B 1321 3R18 B 1321 3RA18 B 20DB015 Normal Duty 5 1321 3R18 B 1321 3RA18 B 1321 3R18 B 1321 3RA18 B 20DB022 Heavy Duty 5 1321 3R18 B 1321 3RA18 B 1321 3R25 B 1321 3RA25 B 20DB022 Normal Duty 7 5 1321 3R25 B 1321 3RA25 B 1321 3R25 B 1321 3RA25 B 20D
164. Y WHETHER OR NOT INSURED WILL NOT EXCEED THE COST OF THE PRODUCT S GIVING RISE TO THE CLAIM OR LIABILITY SELLER DISCLAIMS ALL LIABILITY RELATIVE TO GRATUITOUS INFORMATION OR ASSISTANCE PROVIDED BY BUT NOT REQUIRED OF SELLER HEREUNDER ANY ACTION AGAINST SELLER MUST BE BROUGHT WITHIN EIGHTEEN 18 MONTHS AFTER THE CAUSE OF ACTION ACCRUES THESE DISCLAIMERS AND LIMITATIONS OF LIABILITY WILL APPLY REGARDLESS OF ANY OTHER CONTRARY PROVISION HEREOF AND REGARDLESS OF THE FORM OF ACTION WHETHER IN CONTRACT TORT INCLUDING NEGLIGENCE AND STRICT LIABILITY OR OTHERWISE AND FURTHER WILL EXTEND TO THE BENEFIT OF SELLER S VENDORS APPOINTED DISTRIBUTORS AND OTHER AUTHORIZED RESELLERS AS THIRD PARTY BENEFICIARIES EACH PROVISION HEREOF WHICH PROVIDES FOR A LIMITATION OF LIABILITY DISCLAIMER OF WARRANTY OR CONDITION OR EXCLUSION OF DAMAGES IS SEVERABLE AND INDEPENDENT OF ANY OTHER PROVISION AND IS TO BE ENFORCED AS SUCH 157 AC Adjustable Frequency Drives Important Safety and Product Information Intellectual Property Indemnity Except as excluded herein Seller will defend any suit or proceeding brought against Buyer arising out of a claim that the design or construction of the Products sold or licensed hereunder by Seller infringes any patent copyright or trademark granted or registered in the country of Seller s shipping destination provided a Buyer promptly notifies Seller in writing of any such claim and any suit or proceedin
165. YNANCO E Catalog code corresponds to output amps in these columns Drive must be programmed to lower voltage to obtain higher currents shown at right 500 600V ac Three Phase Drives IP54 NEMA Type 12 Output Amps Nominal Power Ratings with HIM 480V ac Input 500 600V ac Input Normal Duty Heavy Duty Cat No Frame Cont 1 Min 3 Sec Cont 1 Min 3 Sec kW Hp kW Hp 20A Size 41 48 64 41 48 64 30 40 22 30 E041G3AYNANCO E 52 61 5 82 52 61 5 82 37 50 30 40 E052G3AYNANCO E Catalog code corresponds to output amps in these columns Drive must be programmed to lower voltage to obtain higher currents shown at right Allen Bradley 51 AC Adjustable Frequency Drives PowerFlex 70 Standard Drives Selection Flange Mount Front Chassis IP20 NEMA 1 Heatsink IP66 NEMA Type 4X 12 Position d F 200 240V ac Three Phase Drives Flange Type without Output Amps Nominal Power Ratings HIM 240V ac Inputx 208V ac Input Normal Duty Heavy Duty Cat No Frame Cont 1 Min 3 Sec Cont 1 Min 3 Sec kw Hp kW Hp 20A Size 2 2 2 4 3 3 25 2 7 3 7 0 37 0 5 0 25 0 33 B2P2FOAYNNNCO A 4 2 4 8 6 4 4 8 5 5 7 4 0 75 1 0 0 55 0 75 B4P2FOAYNNNCO A 6 8 9 0 12 7 8 10 3 13 8 1 5 2 0 1 1 1 5 B6P8FOAYNNNCO B 9 6 10 6 14 4 11 12 1 16 5 22 3 0 1 5 2 0 B9P6FOAYNNNCO B 15 3 17 4 23 2 17 5 19 2 26 2 4 0 5 0 3 0 3 0 BO15FOAYNANCO C 22 24 2 33 25 3 27 8 3
166. adley AC Adjustable Frequency Drives Important Safety and Product Information IP 2 Water is dripped onto the enclosure from a drip box having spouts spaced on a 20 mm square pattern at a rainfall rate of 3 mm min The enclosure is placed in 4 fixed positions tilted 15 from its normal operating position under the drip box Test time 2 5 min for each position of tilt Tests for Protection Against Access to Hazardous Parts second characteristic numeral IP 3 IP 4 IP 5 IP 6 IP 7 IP 8 Water is sprayed onto all sides of the enclosure over an arc of 60 from vertical using an oscillating tube device with spray holes 50 mm apart or a hand held nozzle for larger enclosures Flow rate oscillating tube device 0 07 l min per hole x number of holes for hand held nozzle 10 l min Test time oscillating tube 10 min for hand held nozzle 1 min m of enclosure surface area 5 min minimum Same as test for IP 3 except spray covers an arc of 180 from vertical Enclosure is sprayed from all practicable directions with a stream of water at 12 5 l min from a 6 3 mm nozzle from a distance of 2 5 to 3 m Test time 1min m of enclosure surface area to be sprayed 3 min minimum Enclosure is sprayed from all practicable directions with a stream of water at 100 l min from a 12 5 mm nozzle from a distance of 2 5 to 3 m Test time 1min m of enclosure surface area to be
167. al DC series bus inductor Allen Bradley 33 AC Adjustable Frequency Drives PowerFlex 400 User Installed Options Communication Option Kits IP30 NEMA 1 UL Type 1 Conversion Kit Description Cat No Serial Converter Module RS485 to RS232 Description Drive Frame Cat No Description Provides serial communication via DF1 IP30 NEMA 1 UL Type 1 Kit protocol for use with DriveExplorer and DriveExecutive Description Field installed kit Converts drive software 22 SCM 232 to IP30 NEMA 1 UL Type 1 enclosure C 22 JBAC Includes DSI to RS232 serial converter 1203 SFC serial Includes conduit box with mounting screws cable f and plastic top panel 22 RJ45CBL C20 cable and DriveExplorer Lite CD IP30 NEMA 1 UL Type 1 Kit with Serial Cable Communication Option Description 2 0 meter serial cable with a locking low profile 1203 SFC Description Field installed kit Converts drive e ARES connector to connect to the serial converter and a 9 pin to IP30 NEMA 1 UL Type 1 enclosure sub miniature D female connector to connect a computer Includes communication option conduit box Null Cable Converter with mounting Screws and plastic top panel Description For use when connecting the serial converter 1203 SNM to DriveExplorer on a handheld PC DSI Cable rd 22 RJ45CBL Human Interface Module Option Kits and Accessories A eps C20 Description Cat No
168. al Duty 75 1321 3R80 C 1321 3RA80 C 1321 3R80 C 1321 3RA80 C 20BE099 Heavy Duty 75 1321 3R80 C 1321 3RA80 C 1321 3R80 C 1321 3RA80 C 20BE099 Normal Duty 100 1321 3R100 C 1321 3RA100 C 1321 3R100 C 1321 3RA100 C 20BE125 Heavy Duty 100 1321 3R100 C 1321 3RA100 C 1321 3R100 C 1321 3RA100 C 20BE125 Normal Duty 125 1321 3R130 Ct 1321 3RA130 C 1321 3R130 Ct 1321 3RA130 C 20BE144 Heavy Duty 125 1321 3R130 C 1321 3RA130 C 1321 3R130 C 1321 3RA130 C 20BE144 Normal Duty 150 1321 3R160 C 1321 3RA160 C 1321 3R160 C 1321 3RA160 C Input line reactors were sized based on the NEC fundamental motor amps Output line reactors were sized based on the VFD rated output currents 4 impedance Allen Bradley 89 AC Adjustable Frequency Drives PowerFlex 700 Factory Installed Options Human Interface and Wireless Interface Modules IP20 NEMA Type 1 Position e Catalog Code 0 Catalog Code 2 Catalog Code 3 Internal Brake IGBT No HIM Blank Cover LCD Digital Speed LCD Full Numeric Catalog Code 5 Catalog Code 8 LCD Programmer Only DPI WIM Catalog Code J Catalog Code K Door Mounted LCD Door Mounted LCD Full Numeric Programmer Only IP66 NEMA Type 12 IP66 NEMA Type 12 Documentation ug Description Position f User Manual A No User Manual N Internal Dynamic Brake Resistors These resistors have a limited duty cycle Refer to the PowerFlex Dynamic Braking Selection Guide to determin
169. anent Magnet Control Adv Drive OL Protection Adv Bus Regulation Adv PI Control Spd or Tra Droop Analog Trim Invert Feedback Loss Switchover Stegmann Interface Heidenhain Interface Resolver Interface Stahltronic and Temposonics SSI Interface Integral Position Loop SynchLink DriveLogix Option Inertia Adaptation User Function Blocks Motor Overload Common Bus Capability IP 20 Open 50 C IP 21 NEMA 1 40 C IP 54 Flange 40 C DeviceNet ControlNet Coax ControlNet Fiber EtherNet IP Remote 1 0 RS485 DF1 PROFIBUS DP Interbus Modbus RTU Bluetooth PowerFlex 7000 Medium Voltage 7000A 7000B 7000C N A 2400V 60Hz 150 1500 kW 200 2000 HP 3300V 50Hz 187 2050 kW 250 2750 HP 4160V 50 60Hz 260 3730 kW 350 5000 HP 6600V 50Hz 400 6340 kW 500 8500 HP Digital Sensorless Direct Vector Full Vector Control with Tach Feedback optional 6 5KV SGCT Power Semiconductor with Integrated Gate Drive Patented PowerCage Converter Modules Set up Wizard Auto Tuning Remote Dial In Access Field Programmable Gate Arrays Drive Identity Module IP 21 NEMA 1 40 C Internal DPI DeviceNet ControlNet Coax ControlNet Fiber EtherNet IP Remote 1 0 RS485 DF1 RS485 HVAC Modbus RTU Modbus Plus PROFIBUS DP RS232 DH Bluetooth AC Adjustable Frequency Drives PowerFlex Selection Guide PowerFlex Standard Packaged Drives PowerFlex 40 Standard Attributes Ca
170. arately DSI HIM Cable DSI HIM to RJ45 cable PROFIBUS DP Communication Adapter 1 0 Meter 3 3 Feet 22 HIM H10 Note Requires a Communication Adapter Cover when 22 COMM P 2 9 Meter 9 51 Feet 22 HIM H30 used with Frame B and C PowerFlex 40 drives Ordered ee Separately The 22 HIM C2S is smaller than the 22 HIM C2 and cannot be used as a External DSI Communications Kit direct replacement Description External mounting kit for 22 COMM D E and 22X CONN P DC BASE Spare Parts External Comms Power Supply 20 XCOMM Description Optional 100 240V ac Power Supply for AC PS1 Description Cat No External DSI Communications Kit Fan Replacement Kit Frame B 1 Fan SK U1 FAN1 B1 Compact I O Module 3 Channel 1769 SM2 Fan Replacement Kit Frame B 2 Fans SK U1 FAN2 B1 Communication Adapter Cover Fan Replacement Kit Frame C 1 Fan SK U1 FAN1 C1 un the Communication Adapter for Frame Fan Replacement Kit Frame C 1 Fan 15 Hp SK U1 FAN1 C2 Note This cover adds 25 mm 0 98 in to the overall depth Frame B Cover with Power Terminal Guard SK U1 BCVR1 B1 of the drive Frame C Cover with Power Terminal Guard SK U1 BCVR1 C1 Frame B Drive 22B CCB Frame B Cover Black without Logo SK U1 CVR2 B1 Frame C Drive 22B CCC Frame C Cover Black without Logo SK U1 CVR2 C1 Frame B Cover for Comm Option Black without Logo SK U1 CVR2 BC Frame C Cover for Comm Option Black without Logo Allen Bradley SK U1 CVR2 CC If
171. arties who have authority to settle the dispute If unsuccessful the parties further will attempt in good faith to settle the dispute by non binding third party mediation with mediator fees and expenses apportioned equally to each side Any dispute not so resolved by negotiation or mediation may then be submitted to a court of competent jurisdiction in accordance with the terms hereof These procedures are the exclusive procedures for the resolution of all such disputes between the parties Governing Law and Forum The agreement evidenced hereby and all disputes arising thereunder will be governed by and interpreted in accordance with the internal laws and will be subject to the exclusive jurisdiction of the courts of the state province or other governmental jurisdiction in which Seller s principal place of business resides but specifically excluding the provisions of the 1980 UN Convention on Contracts for the International Sales of Goods Should any term or provision hereof be held wholly or partly invalid or unenforceable under applicable law the remainder of the agreement evidenced hereby will not be affected thereby Assignment The agreement evidenced hereby may not be assigned by either party without the written consent of the other which consent will not be unreasonably withheld However consent will not be required for internal transfers and assignments as between Seller and its parent company subsidiaries or affiliates as par
172. ased on application requirements i e nominal Hp voltage and duty cycle The basic package for NEMA Type 1 applications will include a standard NEMA Type 1 drive mounted on a back plate The basic package for NEMA Type 4 12 or 3 4 will include a flange mount drive mounted inside the enclosure Step 2 Specify Options The following pages list and describe the available mounted options The listing is divided into simple categories to assist in quickly locating specific needs Some options are horsepower and or voltage specific or will have special rules associated with them Read all Footnotes Step 3 Specify enclosure NEMA Type 1 All options will be further defined by an Area Factor Area Factor is a representation of the mounting space required for a specific option Total all the area factors of all the options selected and choose an enclosure option that is equal or larger in area factor NEMA Type 4 12 Indoor or Type 3 4 Outdoor Enclosure size will be dependent on the type of options selected A combination of heat dissipation and physical space required has been calculated to determine optimal enclosure size Select enclosure size NEMA Type 1 area factors Do Not Apply Example An application requires a variable speed control for an existing 3 Hp 230V normal duty AC conveyor motor The drive and motor will be located in a clean environment Local control is required for programming start stop speed and emergen
173. ased on the NEC fundamental motor amps Output line reactors were sized based on the VFD rated output currents Allen Bradley 57 AC Adjustable Frequency Drives PowerFlex 70 Input and Output Line Reactors 480V 60 Hz Three Phase 5 Impedance Input Line Reactor Output Line Reactor IPOO Open Style IP11 NEMA Type 1 IPOO Open Style IP11 NEMA Type 1 Drive Cat No Duty Hp Cat No Cat No Cat No Cat No 20AD1P1 Heavy Duty 0 33 1321 3R1 B 1321 3RA1 B 1321 3R2 C 1321 3RA2 C 20AD1P1 Normal Duty 0 5 1321 3R1 B 1321 3RA1 B 1321 3R2 C 1321 3RA2 C 20AD2P1 Heavy Duty 0 75 1321 3R2 C 1321 3RA2 C 1321 3R2 B 1321 3RA2 B 20AD2P1 Normal Duty 1 0 1321 3R2 B 1321 3RA2 B 1321 3R2 B 1321 3RA2 B 20AD3P4 Heavy Duty 1 5 1321 3R4 D 1321 3RA4 D 1321 3R4 D 1321 3RA4 D 20AD3P4 Normal Duty 2 0 1321 3R4 D 1321 3RA4 D 1321 3R4 D 1321 3RA4 D 20AD5PO Heavy Duty 2 0 1321 3R4 D 1321 3RA4 D 1321 3R8 D 1321 3RA8 D 20AD5PO Normal Duty 3 0 1321 3R8 D 1321 3RA8 D 1321 3R8 D 1321 3RA8 D 20AD8PO Heavy Duty 3 0 1321 3R8 D 1321 3RA8 D 1321 3R8 C 1321 3RA8 C 20AD8P0 Normal Duty 5 0 1321 3R8 C 1321 3RA8 C 1321 3R8 C 1321 3RA8 C 20AD011 Heavy Duty 5 0 1321 3R8 C 1321 3RA8 C 1321 3R12 C 1321 3RA12 C 20AD011 Normal Duty 7 5 1321 3R12 C 1321 3RA12 C 1321 3R12 C 1321 3RA12 C 20AD014 Heavy Duty 7 5 1321 3R12 C 1321 3RA12 C 1321 3R18 C 1321 3RA18 C 20A
174. ass Std 240V Engineered Drives Program Only m Be Auto Bypass Reseved C1 Drive Only Control Power 05 115V User Supplied Control Power j E9 Enclosure Nameplate Cana Sil G1 Johnson O Metasys Code Version Special Options E Aux Contacts Control Power On c ControlNet Coax Code Type J2 Aux Contacts Drive Fault D DeviceNet Qs Quick Ship J3 Aux Contacts Alarm E EtherNet IP J4 Aux Contacts Run Interbus J5 Aux Contacts At Speed P PROFIBUS J6 Programmable Relay A R RIO J7 Programmable Relay B S RS 485 J8 Motor Heater Control N None L1 396 Input Line Reactor H HVAC L2 3 Output Line Reactor L LonWorks M3 Motor Run Meter Drive Bypass Engineered Drives Program Only N1 Isolated Analog Input 0 10V DC N2 Isolated Analog Input 4 20 mA N3 Isolated Analog Output 0 10V DC k N5 Building Mng Control Interface Vo P18 No Input Protection Code Control 1 0 Volts P2 Input Fuses Drive A Std 24V dc ac P3 Circuit Breaker Drive B Std 115V ac P4 Circuit Breaker Drive Bypass Mode C Vector 24V dc P6 8 Drive Disconnect Switch D Vector 115V ac P7 8 Drive Bypass Mode Fused Disc P11 Drive Input Contactor P12 Drive Output Contactor S1 H O A S S Start Stop Spd Ref S9 Run Pilot Light S10 Drive Fault Pilot Light S11 At Speed Pilot Light S12 Drive Alarm Pilot Light S13 Control Power On Pilot Light S14 Drive 8 Bypass Mode Pilot Lights 815 Bypass Mode amp Auto Bypass En PL 816 Drive D
175. atch the values of the catalog number code in positions a b c etc with the tables labeled a b c etc below 1 3 4 5 6 8 9 220 D 038 A a b C d a c1 Drive Rating Code Type 200 240V Input 22C PowerFlex 400 Code Amps kW Hp Frame 012 12 2 2 8 0 C b 017 17 5 3 7 5 0 C gt 024 24 5 5 17 5 C Voltage Rating 033 33 7 5 10 C Code Ph B 240V ac 3 049 49 11 15 D 065 65 15 20 D D 480V ac 3 075 75 18 5 25 D 090 90 22 30 D 120 120 30 40 E 145 145 37 50 E c2 Rating 380 480V Input Code Amps kW Hp Frame 6PO 6 0 2 2 3 0 C 010 10 5 4 0 5 0 C 012 12 5 5 7 5 C 017 17 7 5 10 C 022 22 11 15 C 030 30 15 20 C 038 38 18 5 25 D 045 45 5 22 30 D 060 60 30 40 D 072 72 37 50 E 088 88 45 60 E 105 105 55 75 E 142 142 75 100 E 170 170 90 125 F 208 208 110 150 F 32 d Enclosure Code Enclosure Panel Mount IP20 UL Open Type Panel Mount A IP30 NEMA 1 UL Type 1 Flange Mount IP20 UL Open Type Frame C drives only available with IP20 UL Open Type enclosure Field installed conversion kit available to achieve IP30 NEMA 1 UL Type 1 rating Frame D E and F drives only available with IP30 NEMA 1 UL Type 1 enclosure Frame C drives only F e HIM Code Interface Module il Fixed Keypad f Emission Class Code Rating 0 Not Filtered g Version Code Version 3 RS48
176. ation Module Cat No Center Winder Unwind 9329 KAA12A 5 hours Inline Tensioning 9329 KAA12B 3 hours Lead Line Control 9329 KAA12C 2 hours Positioning Point to Point 9329 KAA11D 3 hours Process Line Suite 9329 KAA12bE 10 hours Function Modules Spindle Orient None Torque Prove None DriveLogix is required for use with the Drive Application Software Application Modules Phone support is application related technical phone support and is in addition to standard drives support included with hardware purchases t Restricted Access Contact Drive Application Software Product Manager or Drives Negotiation Team to place order These programs are available to OEMs and System Integrators with in house services capable of on site commissioning complete support and service of the applications Media Application Modules User Manuals are distributed on CD ROM The License Agreement with Serial Number is also provided for downloading the software from the Internet at http www ab com drives drvappsw Function Modules User Manuals are located on the internet at http www ab com drives drvappsw A serial number is not needed for download Rockwell Automation is committed to maintaining and supporting Allen Bradley drives and installations Included in this commitment is start up support and consultation for drive applications 143 AC Adjustable Frequency Drives PowerFlex 700S ProtectionP
177. ator Devices Door Mounted Option Description Code H O A S S Start Stop Spd Ref 81 36 Run Pilot Light S9 Drive Fault Pilot Light S10 x At Speed Pilot Light S11 Drive Alarm Pilot Light S12 x Control Power On Pilot Light 813 Drive amp Bypass Mode Pilot Lights 814 E 2 Bypass Mode amp Auto Bypass En PLL S15 gt Drive Disable Mushroom P B S16 3 Motor Fault Pilot Light 817 He Maximum of two drive digital options can be selected NOTE S9 J4 One Digital Output S10 J2 One Digital Output S11 J5 One Digital Output 12 J3 One Digital Output All other combinations One Digital Output This requires option C1 or user supplied 115V option C5 Option available when B1 is selected Option available when B2 is selected 3 Does not require option C1 or user supplied power C5 if 24V ac dc interface is selected Requires option C1 or user supplied power C5 if 115V ac interface is selected 100 Meters Door Mounted Description Drive Bypass Motor Run Time Meter Elapsed Hours Non Resettable dug s This requires option C1 or user supplied 115V option C5 Enclosure Options Option Code Description Nameplate Door Mounted 158 8 x 50 8 mm 6 25 x 2 in white Lamacoid with black letters ABS o UL Type 3 4 12 ae Actual message to be defined by user at order entry otherwise will be supplied blank Codes and Sta
178. ble Frequency Drives PowerFlex 700 Packaged Drives Programs Suggested Power Distribution Schemes Mai Breaker Option P3 Fused Disconnect Option P6 PowerFlex PowerFlex 700 700 Drive Drive Output Contactor I Output Contactor Option P12 Option P12 Circuit Breaker o Option P3 y Bypass System O O Circuit Breaker Option P4 Input Contactor oO Option P11 1 Input Contactor PowerFlex Option P11 700 Dive PowerFlex 700 Drive eL Bypass m T Option B1 add B2 if Auto Bypass is Required A User Connection Point a NE ocu 1 User Supplied No Input Protection User Supplied No Input Protection Protection amp Option P1 Disconnect Option P1 Disconnect Lbl Drive Input Fuses Option P2 PowerFlex 700 Drive PowerFlex 700 Drive Output Contactor Option P12 Output Contactor 98 Option P12 Bypass System Fused Disconnect Option P7 ass Input Contactor Option P11 PowerFlex 700 Drive Bypass Option B1 add B2 if Auto 58 Bypass is Required User Connection Point User Supplied Protection amp Disconnect No Input Protection Option P1 Input Contactor Option P11 PowerFlex 700 Drive us Bypass eS Option B1 add B2 if Auto amp Bypass is Required User Connection Point Allen Bradley Power Disconnecting Means Important Cus
179. ble if damage is too great Modules with electrostatic sensitive components should be handled by the edges without touching components or printed circuit conductors Use packaging material supplied with the replacement module when shipping the module to the manufacturer for repair When the scope of repairs exceeds the manufacturer s recommendations for field repair the module s should be returned to the manufacturer for repair Doing so will help to ensure that only properly selected components are used and that all necessary hardware and firmware revisions are incorporated into the repair Failure to make necessary updates may result in safety compatibility or performance problems which may not become apparent for some time after the repaired module has been placed back in service When firmware is protected by copyright law updates can be provided legally only by the manufacturer or licensee Allen Bradley 5 4 Safety Recommendations for Maintenance Personnel All maintenance work should be done by qualified personnel familiar with the construction operation and hazards involved with the equipment The appropriate work practices of NFPA 70E should be followed Product Compliance Product Compliance Information For your quick reference product certification information can be found at www ab com certification Actual product certification is indicated by the label s on the product and not by a listing on this website o
180. ccessories 20 HIM C5 20 HIM C5S Handheld Local Drive Remote Panel Mount Mount IP66 UL Type 4x 12 Description Cat No Cat No Blank Plate 20 HIM AO LCD Display Digital 20 HIM A2 _ Speed i 20 HIM C3 LCD Display Full DO IMAS Numeric Keypad 20 HIM C3S 8 i 20 HIM C5 LCD Display 20 HIM AB t Programmer Only 20 HIM C5S 5 DPI NEMA 1 WIM 20 WIM N1 DPI NEMA 4 WIM 20 WIM N4S User installed drive mounted available only on IP20 NEMA Type 1 and Flange Type See Factory Installed Options for drive mount IP66 NEMA Type 4X 12 HIM For indoor use only t Includes a PowerFlex HIM Interface Cable 20 HIM H10 5 Includes a 1202 C30 cable 3 Meters Allen Bradley Description Cat No Bezel Kit for LCD HIMs NEMA 1 20 HIM B1 PowerFlex HIM Interface Cable 1 m 39 in 20 HIM H10 HIM Comm Cable Kit Male Female 3 0 33 Meters 1 1 Feet 1202 H03 1 Meter 3 3 Feet 1202 H10 3 Meter 9 8 Feet 1202 H30 9 Meter 29 5 Feet 1202 H90 Comm Option Cable Kit 0 33 Meters 1 1 Feet 1202 C03 1 Meter 3 3 Feet 1202 C10 3 Meter 9 8 Feet 1202 C30 9 Meter 29 5 Feet 1202 C90 De Kit with Connectors Tools and 100 m 328 1202 CBL KIT 100M DPI Cable Connector Kit 1202 TB KIT SET DPI SCANport One to Two Port Splitter Cable 1203 503 Includes an interface cable 1202 C30 for connection to drive Required only when HIM is used a
181. ceNet is the communication protocol provided with the ArmorStart including DeviceLogix The Bulletin 284A ArmorStart Distributed Motor Controller allows connectivity to the ArmorPoint backplane The ArmorPoint I O system can communicate using DeviceNet ControlNet and EtherNet communication protocols In addition to the different network protocols the ArmorPoint Distributed I O products allow the I O capability to be expanded beyond the standard two outputs The two outputs that are 28 provided as standard which are a dual key connector are sourced from the control voltage power of 24V DC 120V AC or 240V AC LED status indication is also provided as standard with ArmorPoint When using the ArmorPoint a maximum of two ArmorPoint Distributed Motor Controllers can be connected to the ArmorPoint Distributed I O product Factory Installed Options HOA Selector Keypad with Jog Function The HOA Selector Keypad with Jog Function allows for local start stop control with capabilities to JOG and to Forward Reverse motor direction EMI Filter The EMI Filter option is required if the Bulletin 284 ArmorStart Distributed Motor requires to be CE compliant If the EMI Filter is selected a 3 meter shielded 4 conductor cordset is provided as standard This option is only available with sensorless vector control Dynamic Brake Connector A 3 meter 3 pin cable for connection to a dynamic brake module is provided as standard when this option i
182. censed and cannot be transferred or resold On site commissioning and support services are not included with Drive Application Software Application Module Center Winder Unwind is used for center driven variable diameter process line applications requiring Loadcell Dancer or Open Loop web tension control Application Module Inline Tensioning is used for constant diameter process line applications requiring Loadcell Dancer or Draw web tension control Application Module Lead Line Control is used for lead section control and line coordination with support for progressive and regressive draw This Application Module works with the Center Winder Unwind and Inline Tensioning Application Modules Application Module Positioning Point to Point is used for point to point position control with support for selectable target positions Learn Target function and Homing functions Function Module Spindle orient is used to position a motor to a precise location regardless of whether the motor is starting from standstill or rotating at high speed The location is defined by a marker pulse Function Module TorqueProv is used to automate torque and brake proving for lifting applications Process Line Suite of Application Modules includes the Lead Line Control Inline Tensioning and Center Winder Unwind application modules Allen Bradley Product Selection Phone Support Applic
183. compatible with PC tools such as DriveExplorer and DriveTools SP which assist with programming monitoring and troubleshooting PowerFlex drives AC Adjustable Frequency Drives PowerFlex 4 Catalog Number Explanation To interpret the meaning of a catalog number match the values of the catalog number code in positions a b c etc with the tables labeled a b c etc below Position 1 3 4 5 6 8 9 10 1f 12 13 14 a b C d e f g h a c4 f Drive Rating Emission Class Code Type 200 240V Three Phase Input Code Rating 22A PowerFlex 4 Code Amps kW Hp 0 Not Filtered 1 5 15 0 2 0 25 1 Filtered b 2PS 2 3 0 4 0 5 Voltage Rating 4P5 4 5 0 75 1 0 g ma oa of 8PO 8 0 1 5 2 0 Code Voltage Ph Version 22957 90 A 012 12 0 2 2 3 0 V 120V ac 1 am 175 37 5 0 Code Version A 240V ac 1 9 No Brake IGBT B 240V ac 3 4 Standard D 480V 3 ico a This position of the Catalog Number now Rating indicates drive version All PowerFlex 4 drives c1 380 480V Three Phase Input are equipped with RS485 communication mum eu ome omm 100 120V Single Phase Input 205 h Goede Amps kW Hp 2P3 2 3 0 75 1 0 j 1P5 15 0 2 0 25 4PO 4 0 1 5 2 0 Optional 2P3 23 0 4 0 5 6PO 6 0 2 2 3 0 Purpose 4P5 45 0 75 1 0 8P7 8 7 3 7 5 0 AA through ZZ Reserved for custom firmware 6PO 6
184. ctions for I O communications and motor 4 Inputs and 2 Outputs Expandable with ArmorPoint LED Status Indication DeviceNet Communications DeviceLogix Component Technology Connectivity to ArmorPoint Distributed I O Products ControlNet and EtherNet Communication via ArmorPoint Factory Installed Options Hand Off Auto HOA Keypad Configuration EMI Filter Dynamic Brake Connector Output Contactor Source Brake Contactor Shielded Motor Cable Safety Monitor 0 10V Analog Input Table of Contents Conformity to Standards this page 27 Description this page Description of Features page 28 Catalog Number Explanation page 29 Product Selection page 29 Product Line Overview page 30 Conformity to Standards cULus File No E207834 UL 508C EN IEC 60947 1 EN 50178 EN 61800 3 CE Marked per Low Voltage Directive 73 23 EEC and EMC Directive 89 336 EEC Description The Bulletin 284 ArmorStart Distributed Motor Controller is an integrated pre engineered combination starter for variable frequency AC drive applications The ArmorStart offers a robust IP 67 Nema Type 4 enclosure design which is suitable for water wash down environments The modular plug and play design offers simplicity in wiring the installation The quick disconnects for the I O communication and motor connection reduce the wiring time and eliminate wiring errors The ArmorStart offers
185. cy stop Operation across the line with selection and mode indication at drive is required A system disconnect switch should be available The speed reference will be supplied either local or from an isolated remote process control and should be selectable at the drive Control power is required Description Cat No Option Code Area Factor Basic Drive 21AB9P6 AO Human Interface Module LED H1 AO Drive Disable Pushbutton D5A Al Bypass Manual with D O B Switch BM1 A54 Drive 8 Bypass Mode Pilot Lights D4A Al Drive Disconnect Switch DS AO Hand Off Auto D1A A1 Control Power CF A16 Total Area Factor A83 IP 20 NEMA Type 1 Enclosure AA2 A130 21AB9P6 AA2 BM1 CF DS D1A D4A D5A H1 Allen Bradley 65 AC Adjustable Frequency Drives PowerFlex 70 Packaged Drives Programs Product Selection Base Enclosure Factory Installed Options 36 Drive Input Protection Must Choose One Optional AF NEMA Base Enclosure Type4 12 Indoor Fused AA1 or AH NEMA Circuit Disconnect Drive Input IP20 NEMA type 3 4 Breaker Switch Drive Input No Input Type 1 Outdoor System System Fusing Protection Contactor Output Amps Ratings Less HIM Less HIM CB gt DS FB t CNP KD Drive Cat Frame No Area Cont 1 Min 3Sec NDHp HDHp Size 21A Fac Cat No
186. d based on the VFD rated output currents Output Line Reactors 480V 60 Hz Three Phase 5 Impedance Output Line Reactor IPOO Open Style IP11 NEMA Type 1 Drive Cat No Duty Hp Cat No Cat No 20CD261 Heavy Duty 150 1321 3R200 C 1321 3RA200 C 20CD261 Normal Duty 200 1321 3RB250 C 1321 3RAB250 C 20CD300 Heavy Duty 200 1321 3RB250 C 1321 3RAB250 C 20CD300 Normal Duty 250 1321 3RB320 C 1321 3RAB320 C 20CD385 Heavy Duty 250 1321 3RB320 C 1321 3RAB320 C 20CD385 Normal Duty 300 1321 3RB400 C 1321 3RAB400 C 20CD460 Heavy Duty 300 1321 3RB400 C 1321 3RAB400 C 20CD460 Normal Duty 350 1321 3R500 C 1321 3RA500 C 20CD500 Heavy Duty 350 1321 3RB400 C 1321 3RAB400 C 20CD500 Normal Duty 450 1321 3R500 C 1321 3RA500 C 20CD590 Heavy Duty 450 1321 3R500 C 1321 3RA500 C 20CD590 Normal Duty 500 1321 3R600 C 1321 3RA600 C 20CD650 Heavy Duty 500 1321 3R600 C 1321 3RA600 C 20CD650 Normal Duty 500 1321 3R750 C 1321 3RA750 C 20CD730 Heavy Duty 500 1321 3R750 C 1321 3RA750 C 20CD730 Normal Duty 600 1321 3R750 C 1321 3RA750 C 20CD820 Heavy Duty 600 1321 3R750 C 1321 3RA750 C 20CD820 Normal Duty 700 1321 3R850 C 1321 3RA850 C 20CD920 Heavy Duty 700 1321 3R850 C 1321 3RA850 C 20CD920 Normal Duty 800 1321 3R1000 C 1321 3RA1000 C 20CD1030 Heavy Duty 800 1321 3R1000 C 1321 3RA1000 C 20CD1030 Normal Duty 900 1321 3R1000 C 1321 3RA1000 C PowerFlex 700H has an integral
187. d by Seller exclusively will govern the sale or licensing by Seller of all goods and services including without limitation hardware firmware and software products training programming maintenance engineering parts repair and 156 remanufacturing services hereinafter Products furnished to Buyer hereunder whether such sale or licensing is effected by paper based transactions or via facsimile or other forms of electronic data interchange EDI or electronic commerce and represents the entire agreement between Buyer and Seller with respect thereto Buyer s receipt or acceptance of delivery of any of the Products ordered or purchased hereunder will constitute its acceptance of these terms and conditions No addition or modification to these terms and conditions will be binding on Seller unless agreed to in writing signed by an authorized representative at Seller s headquarters Seller objects to and rejects other terms and conditions that may be proposed by Buyer or that appear on or are referenced in Buyer s purchase order or requisition that are in addition to or otherwise not consistent with the terms and conditions set forth or referenced herein Payment Terms Net thirty 30 days from date of invoice with ongoing approved credit as determined by Seller Seller may render partial invoices and require progressive payments Seller reserves the right to render invoices electronically and to receive payment by way of
188. d in this publication Engineered options that are listed within this publication will be specified by the heading Engineered Drives Program Only and will have varied lead times Entering a custom quote request for additional options not listed A custom quote will require a Passport quote using SP SDB CUSTOM as the line item part number and entering a description of the base catalog string and custom options in the Competitive Summary For questions or help with a custom quote please contact the Engineered Drives Group at 262 512 8415 104 Allen Bradley AC Adjustable Frequency Drives PowerFlex Drive Packages for Fan amp Pump Applications Catalog Number Explanation 1 3 4 5 7 8 21V D 2P1 A a b e d a Drive Code Type 21V PowerFlex 70 Drive 21W PowerFlex 700 Drive b Voltage Rating Code Voltage Ph x 208V ac 3 D 480V ac 3 E 600V ac 3 c1 ND Rating 208V 60Hz Input Code Amps Frame kW HP 4P2 4 8 B 0 75 1 0 6P8 7 8 B 1 5 2 0 9P6 11 B 2 2 3 0 015 17 5 C 4 0 5 0 022 25 3 D 5 5 7 5 028 32 2 D 7 5 10 042 43 D 11 15 c2 ND Rating 480V 60Hz Input Code Amps Frame kw HP 2P1 2 1 B 0 75 1 0 3P4 3 4 B 1 5 2 0 5PO 5 0 B 2 2 3 0 8PO 8 0 B 4 0 5 0 011 11 C 5 5 7 5 014 14 C 7 5 10 022 22 D 11 15 027 27 D 15 20 034 34 D 18 5 25 040 40 D 22 30 052 52 E 30 40 065 65 E 37 50 0778 77 4 45 60
189. device is operated at 30 operations per minute No test liquid shall enter the enclosure Type For a Degree of Protection Against Designed to Meet Class National 7 Class Group 9 Class Il Group Atmospheres Typically Containing Tests Electrical Code A B C D E F G Acetylene Y Hydrogen Manufactured Gas Explosion Y Y Hydrostatic and Diethyl Ether Ethylene Hydrogen Sulfide Temperature Test Y Acetone Butane Gasoline Propane Toluene Y Y Metal dusts and other combustible dusts with resistivity of less than 10 ohm cm Dust Penetration Test Carbon black charcoal coal or coke dusts with resistivity Temperature Test with X between 10 10 ohm cm Dust Blanket Combustible dusts with resistivity of 10 ohm cm or greater Il Y Fibers flyings ll Y For indoor locations only unless cataloged with additional NEMA Type enclosure number s suitable for outdoor use as shown in table on page Important 9 Some control devices if so listed in the catalog are suitable for Division 2 hazardous location use in enclosures for non hazardous locations For explanation of CLASSES DIVISIONS and GROUPS refer to the National Electrical Code Note Classifications of hazardous locations are subject to the approval of the authority having jurisdiction Refer to the National Electrical Code See abridged description of test requirements below For complete requirements re
190. e DAB Al D5 Drive Disable Push Pull M H P B DBA A1 D6 Motor Fault Pilot Light D6A A1 gt Applies to NEMA Type 1 enclosures only Requires user supplied control power or the CF option Must be used with options BM1 or BM2 Must be used with options BA BM1 or BM2 Allen Bradley gt Applies to NEMA Type 1 enclosures only 8 NEMA Type 1 enclosure size will be dependent on the total option Area Factors Add up all the option Area Factors to determine enclosure size When exact dimensions are required consult factory See Enclosure Selection for proper NEMA Type 3 4 outdoor or 4 12 indoor enclosure selection Codes and Standards Code Standard Action Not available on this CE European Conformance Standard product IEEE519 Not available on this iii Harmonic Distortion Levels product This program provides UL panel recognition from the factory as standard UL c UL CSA 69 AC Adjustable Frequency Drives PowerFlex 70 Packaged Drives Programs Drawing and Test Options Description One Set of Cat No Manufacturing Drawings 279 x 432 mm 11 x 17 in One set of schematics Information Only Manufacture Proceeding Not to be used as Approval Drawings Diskette 1301 MFDISK Electronic Drawings 1301 MFDWG E Black amp Whites 1301 MFDWG Vellums 1301 MFRV Final Drawings as shipped 279 x 432 mm 11 x 17 in One set of
191. e Standard Packaged Drives Program allows users to create drive packages based on their specific needs A complete drive package may be specified by assembling a single catalog number string that includes a base drive and all required options Packaging is available for 480V requirements in NEMA Type 1 IP20 and NEMA 12 IP54 Fan and Filter The program consists of a fully defined catalog string identified within this price sheet Focused on higher volume repeat business the standard designs provide consistent manufacturing and minimizes customer resources by reducing engineering manufacturing and installation time Typical delivery is 10 15 business days from order entry and can be ordered through the order entry system Engineered Drives The Engineered Drives Program offers users the ability to create drive packages beyond the Standard Packaged Drives offering Options may or may not be defined within this publication Product can be ordered by Assembling a catalog string from the options listed in this publication Engineered options that are listed within this publication will be specified by the heading Engineered Drives Program Only and will have varied lead times Entering a custom quote request for additional options not listed A custom quote will require a Passport quote using SP SDB CUSTOM as the line item part number and entering a description of the base catalog string and custom options in the Competitive Summary For qu
192. e and delivery of the Products must be documented in writing and are subject to Seller s prior approval and adjustments in price scheduling and other affected terms and conditions In any event Seller reserves the right to reject any change that it deems unsafe technically inadvisable or inconsistent with established engineering or quality guidelines and standards or incompatible with Seller s design or manufacturing capabilities Seller further reserves the right to substitute using the latest superseding revision or series or equivalent Product having comparable form fit and function Allen Bradley AC Adjustable Frequency Drives Important Safety and Product Information Returns All returns of Products will be pursuant to Seller s instructions Non warranty returns of unused and resalable Products for credit will be subject to Seller s return policies in effect at the time including applicable restocking charges and other conditions of return Products returned under warranty must be properly packed and shipped to Seller specified locations Shipping containers must be clearly marked per Seller s instruction and shipped freight prepaid by Buyer Notwithstanding the foregoing all sales of Open Box Products and any third party branded products are final and do not qualify for non warranty return Order Cancellation Cancellation by Buyer prior to shipment is permitted only by written notice and upon payment to Sell
193. e if an internal resistor will be sufficient for your application An external resistor may be required Drive Input Brake Resistance Cat Code Voltage Frame Position h 0 62 ye 1 2 5 Hp 62 M 208 240V ac 1 7 5 Hp 22 Y 2 22 Y 0 115 Y 380 480V ac 1 115 M 2 68 Y 90 Drive Input Cat Code Voltage Brake IGBT Frame Position g 208 480V ac Standard 0 3 M 208 480V ac Optional 4 M 208 690V ac Optional 5 M 208 690V ac Optional 6 Y The Internal Brake IGBT option can not be field installed Internal EMC Filter and Common Mode Choke Drive Input Common Cat Code Voltage Frame CE Filter Mode Choke Position i 208 240V ac 3 with Filter with Choke A 208 240V ac 0 3 with Filter No Choke B 208 240V ac 4 6 with Filter with Choke A 380 480V ac 0 6 with Filter with Choke A 600 690V ac 0 6 with Filter with Choke A Note CE Certification testing has not been performed on 600V class drives below 77 Amps Internal Communication Adapters Cat Code Description Position j ControlNet C DeviceNet D EtherNet IP E HVAC H Remote l O R RS 485 DF1 S Control and I O Options Cat Code Control Position k Standard Control Open Loop No I O N Standard Control Open Loop 24V dc ac A Standard Control Open Loop 115V ac B Vector Control 24V dct C Vector Control 115V acts D
194. e to male dl 7 indoor use only Includes 2 0 meter cable connectors C20 LCD Display Remote Panel Mount Digital Speed Splitter Cable AK UO RJ45 Control CopyCat capable IP66 NEMA Type 4X 12 22 HIM C2 Description RJ45 one to two port splitter cable SC1 indoor use only Includes 2 9 meter cable xn 7 Terminating Resistors AK U0 RJ45 LCD Display Remote Handheld Digital Speed Control Description 120 Ohm resistor embedded in an RJ45 Full Numeric Keypad CopyCat capable IP30 NEMA connector 2 pieces TRI A 22 HIM A3 p i Type 1 Includes 1 0 meter cable Panel Mount with Terminal Block optional Bezel Kit amparo AK UO RJA5 Description RJ45 two position terminal block 5 pieces TB2P Remote Handheld Wireless Interface Module with with two 120 Ohm terminating resistors loose Bluetooth technology IP30 NEMA Type 1 Panel 22 WIM N1 A aay A DeviceNet Communication Adapter Mount with optional Bezel Kit oae Note Requires a Communication Adapter Cover when Remote Panel Mount Wireless Interface Module with used with Frame B and C PowerFlex 40 drives Ordered 22 COMM D Bluetooth technology IP66 NEMA Type 4X 12 indoor 22 WIM N4S Separately 2 ony EtherNet IP Communication Adapter Bezel Kit Panel Mount for LCD Display Remote Note Requires a Communication Adapter Cover when 22 COMM E Handheld unit IP30 NEMA Type 1 Includes a 22 22 HIM B1 used with Frame B and C PowerFlex 40 drives Ordered RJ45CBL C20 cable Sep
195. ector Max Load 25 mA DriveLogix I O Option Flex I O up to 1 rail 8 modules Allen Bradley AC Adjustable Frequency Drives PowerFlex 700S Phase I Catalog Number Explanation Position 1 3 4 5 7 8 9 10 11 12 13 14 15 16 17 20D D 2P1 A 0 E Y N A N N N N a b e d e f g h i j k l m a c2 c3 Drive ND Rating ND Rating Code Type 400V 50 Hz Input 480V 60 Hz Input 20D PowerFlex 700S Code Amps kW Code Amps Hp 2P1 2 1 0 75 2P1 2 1 1 0 3P5 3 5 1 5 3P4 3 4 2 0 5P0 5 0 2 2 5P0 5 3 0 b 8P7 8 7 4 0 8PO 8 5 0 Voltage Rating 011 11 5 5 5 011 11 7 5 Code Voltage Ph Prechg 015 15 4 7 5 014 14 10 B 240V ac 3 022 22 11 022 22 15 C 400V ac a 030 30 15 027 27 20 D 480V ac 3 037 37 18 5 034 34 25 E 600V ac 3 043 43 22 040 40 30 F 690V ac gt 3 056 56 30 052 52 40 H 540V de 32 m N 072 72 37 065 65 50 J 650V dc N 085 85 45 077 77 60 P 540V de gt Y 105 105 55 096 96 75 125 125 55 125 125 100 R 650V dc gt Y meer 140 140 75 156 156 125 Note CE Certification testing has not been performed on 600V class drives 170 170 90 180 180 150 gt Frames 5 8 6 Only 260 260 132 248 248 200 3e Frames 5 amp up 261 261 132 261 261 200 300 300 160 300 300 250 385 385 200 385 385 300 460 460 250 460 460 350 c1 500 500 250 500 500 450 ND Rating 590 590 3
196. electronic funds transfer Payment by credit card when permitted is subject to credit card validation and authorization both at time of agreement and immediately prior to shipment Seller reserves the right to suspend any further performance hereunder or otherwise in the event payment is not made when due No payment by offset is permitted Interest charges will be added to overdue invoices at the rate of 1 5 per month subject to any limit imposed by applicable law Delivery Terms Delivery terms are Ex Works Seller s plant or warehouse per current Incoterms or as otherwise agreed to as evidenced by Seller s order acknowledgment In all cases title transfers to Buyer upon the earlier of Seller s delivery to Buyer or receipt by the first carrier for transport to Buyer except that title to all intellectual property rights associated with the Products remains with Seller or its suppliers and licensors Acknowledged shipping dates are approximate only and based on prompt receipt of all necessary information from Buyer Seller disclaims all liability for late delivery Where applicable prepaid shipping will be billed as a separate invoice item Warranty a Hardware Seller warrants that new hardware Products furnished hereunder will be free from defects in material workmanship and design for a period of one 1 year from the date of invoice from Seller or its appointed distributor as the case may be Repaired or replacement Product
197. er of reasonable cancellation and restocking charges including reimbursement for direct costs Cancellation charges associated with orders for custom Products or Products specifically manufactured to Buyer s specification may equal the actual selling price of the Products Seller has the right to cancel an order for cause at any time by written notice and Seller will be entitled to cancellation and restocking charges as identified above No termination by Buyer for cause will be effective unless and until Seller has failed to correct such alleged cause within forty five 45 days after receipt of Buyer s written notice specifying such cause Force Majeure Seller will not be liable for any loss damage or delay arising out of its failure or that of its subcontractors to perform hereunder due to causes beyond its reasonable control including without limitation acts of God acts or omissions of Buyer acts of civil or military authority fires strikes floods epidemics quarantine restrictions war riots acts of terrorism delays in transportation or transportation embargoes In the event of such delay Seller s performance date s will be extended for such length of time as may be reasonably necessary to compensate for the delay Government Clauses and Contracts Application of government contract regulations and clauses to the Products or the agreement evidenced by these terms and conditions are subject to the separate review and
198. erFlex 70 drive can be used with the full featured LCD Human Interface Module which provides multilingual text for startup metering programming and troubleshooting The PowerFlex 70 can be programmed for Volts per Hertz Sensorless Vector or Vector Control with Force Technology to cover a wide range of applications from fans to extruders Optional internal communication modules provide fast and efficient control and or data exchange with host controllers over popular interfaces These interfaces include DeviceNet ControlNet EtherNet IP Remote I O Serial Communications and other communication networks PC tools such as DriveExplorer and DriveTools SP assist with programming monitoring and troubleshooting the PowerFlex 70 45 AC Adjustable Frequency Drives PowerFlex 70 Catalog Number Explanation Many of the catalog codes below represent factory installed options which can increase lead times Most of these options can also be ordered as user installed with a shorter lead time Refer to page 48 for normally stocked IP20 NEMA Type 1 drives and page 53 for user installed options Position Number 1 3 4 5 7 8 20A B 2P2 A a b C d a Drive Code Type 20A PowerFlex 70 b Voltage Rating Code Voltage Ph B 240V ac 3
199. erFlex Drive Packages for Fan amp Pump Applications NEMA Type 1 without HIM 8 Communication Adapter kW Hp Cont 1 Min 3 Sec Frame Size Cat No 0 75 1 0 4 8 5 5 7 4 B 21VX4P2A0AYNANCOAN 1 5 2 0 7 8 10 3 13 8 B 21VX6P8A0AYNANCOAN 2 2 3 0 11 12 1 16 5 B 21VX9P6A0AYNANCOAN 4 0 5 0 17 5 19 2 26 2 C 21VX015A0AYNANCOAN 5 5 7 5 25 3 27 8 37 9 D 21VX022A0AYNANCOAN 7 5 10 32 2 37 9 50 6 D 21VX028A0AYNANCOAN 11 15 43 55 5 74 D 21VX042A0AYNANCOAN 208V ac 3 Contactor Full Feature Bypass with Disconnect Package Code B NEMA Type 1 without HIM amp Drive Ratings Communication Adapter Output Current kW Hp Cont 1 Min 3 Sec Frame Size Cat No 0 75 1 0 4 8 5 5 7 4 B 21VX4P2A0AYNANCOBN 1 5 2 0 7 8 10 3 13 8 B 21VX6P8A0AYNANCOBN 2 2 3 0 11 12 1 16 5 B 21VX9P6A0AYNANCOBN 4 0 5 0 17 5 19 2 26 2 C 21VX015A0AYNANCOBN 5 5 TS 25 3 27 8 37 9 D 21VX022A0AYNANCOBN 18 10 32 2 37 9 50 6 D 21VX028A0AYNANCOBN 11 15 43 55 5 74 D 21VX042A0AYNANCOBN 460V ac Main Input Disconnect Package Code A NEMA Type 1 without HIM amp Drive Ratings Communication Adapter Output Current kW Hp Cont 1 Min 3 Sec Frame Size Cat No 0 75 1 0 2 1 2 4 3 2 B 21VD2P1A0AYNANCOAN 1 5 2 0 3 4 4 5 6 0 B 21VD3P4A0AYNANCOAN 2 2 3 0 5 0 5 5 7 5 B 21VD5POA0AYNANCOAN 4 0 5 0 8 0 8 8 12 B 21VD8POAOAYNANCOAN 5 5 TS 11 12 1 16 5 C 21VD011A0AYNANCOAN 7
200. estions or help with a custom quote please contact the Engineered Drives Group at 262 512 8415 Allen Bradley 91 AC Adjustable Frequency Drives PowerFlex 700 Packaged Drives Programs Catalog Number Explanation Position 1 3 4 5 7 8 9 10 11 12 13 14 15 21B D 2P A 3 A Y N A R C a b C d e f g h i j k a c2 Drive Rating Code Type Engineered Drives Program 21B PowerFlex 700 Output 240V 60 Hz Input Code Amps ND Hp HD Hp 2P2 2 2 0 5 0 33 b 4P2 4 2 1 0 0 75 6P8 6 8 2 0 15 Voltage Rating 9P6 9 6 3 0 2 0 Code Voltage Ph Type 015 153 5 0 30 B A 3 022 22 75 5 0 Be 240V ac 3 SA 028 28 10 75 Es 600V ac 3 SA 042 42 15 10 Enginesred Dives Program Oniy 052 52 20 15 t Normal duty continuous amps Engineered Drives Program Only c1 Rating Output 480V 60 Hz Input d Code Amps t ND Hp HD Hp Enclosure 1P1 14 0 5 0 33 Code Enclosure 2P1 2 1 1 0 0 75 A IP 20 NEMA Type 1 3P4 3 4 2 0 15 H IP 54 NEMA Type 12 Fan amp 5PO 5 3 0 2 0 Filter 8P0 8 5 0 3 0 011 11 75 5 0 014 14 10 7 5 022 22 15 10 027 27 20 15 034 34 25 20 040 40 30 25 052 52 40 30 065 65 50 40 077 77 60 50 096 96 75 60 125 125 100 75 156 156 125 100 180 180 150 125 248 248 200 150 Normal duty continuous amps 92 16 17 18 19 20 22 23 I m n O e HIM Code Interface Module 3 Drive Mounted Full Numeric LCD HIM NEMA Type 1 12 Dri
201. eviceNet Point I O w IB4 4 Inputs SRO 6 0 2 2 8 0 R5 R3 plus 4 I O Quick Disconnect wile 10 5 35150 h Hand Off Auto S S 012 12 5 5 7 5 ae E i Start Stop Speed Ref 017 17 7 5 10 a Reseved S4 Auto Manual S S Speed Ref 024 24 11 15 S7 Start and Stop P B P S8 Forward Reverse S S d S20 Local Control with Off Run FWD and E Code Rating a Local Remote S S nclosure m N Reserved Local Off Remote with 1 N O Code Enclosure ee Ze S21 Interposing Relay c NEMA Type 4X IP66 This option changes the enclosure rating to B NEMA Type 4 12 IP66 NEMA 1 IP 20 The design of the PowerFlex 40 Standard Packaged Drive supports indoor and outdoor applications that are not in direct sunlight 22 Allen Bradley AC Adjustable Frequency Drives PowerFlex 40 Product Selection 480V ac Base Drive Single Motor Drive Ratings NEMA 4 12 IP66 NEMA 4X IP66 Output Current 40 C kw Hp A Frame Size Cat No Cat No 0 4 0 5 1 4 B 23B D1P4D104NN 23B D1P4C104NN 0 75 1 0 2 3 B 23B D2P3D104NN 23B D2P3C104NN 1 5 2 0 4 0 B 23B D4P0D104NN 23B D4P0C104NN 2 2 3 0 6 0 B 23B D6P0D104NN 23B D6P0C104NN 4 0 5 0 10 5 B 23B D010D104NN 23B D010C104NN 5 5 T5 12 C 23B D012D104NN 23B D012C104NN 7 5 10 17 C 23B D017D104NN 23B D017C104NN 11 15 24 C 23B D024D104NN 23B D024C104NN Factory Installed Options Versio
202. f contract arising therefrom i General Warranty satisfaction is available only if a Seller is provided prompt written notice of the warranty claim and b Seller s examination discloses that any alleged defect has not been caused by misuse neglect improper installation operation maintenance repair alteration or modification by other than Seller accident or unusual deterioration or degradation of the Products or parts thereof due to physical environment or electrical or electromagnetic noise environment j THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES AND CONDITIONS WHETHER EXPRESSED IMPLIED OR STATUTORY INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE OR PERFORMANCE OR APPLICATION WARRANTIES TO THE FULLEST EXTENT PERMITTED BY APPLICABLE LAW Rights under the above warranties subject to noted limitations extend to Buyer s customers if Buyer is a Seller appointed distributor for the Products Disclaimer and Limitation of Liability TO THE FULLEST EXTENT PERMITTED BY APPLICABLE LAW SELLER WILL NOT BE LIABLE FOR ANY BUSINESS INTERRUPTION OR LOSS OF PROFIT REVENUE MATERIALS ANTICIPATED SAVINGS DATA CONTRACT GOODWILL OR THE LIKE WHETHER DIRECT OR INDIRECT IN NATURE OR FOR ANY OTHER FORM OF INCIDENTAL INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND SELLER S MAXIMUM CUMULATIVE LIABILITY RELATIVE TO ALL OTHER CLAIMS AND LIABILITIES INCLUDING OBLIGATIONS UNDER ANY INDEMNIT
203. fer to UL Standard 698 compliance with which is required by NEMA enclosure standards For listing of additional materials and information noting the properties of liquids gases and solids refer to NFPA 497M 1991 Classification of Gases Vapors and Dusts for Electrical Equipment in Hazardous Classified Locations UL 698 does not include test requirements for Class Ill Products that meet Class Il Group G requirements are acceptable for Class Ill 164 Allen Bradley AC Adjustable Frequency Drives Important Safety and Product Information Abridged Description of UL Standard 698 Test Requirements Explosion Test During a series of tests in which gas air mixtures of the specific gas over its range of explosive concentrations are ignited inside the enclosure the enclosure shall prevent the passage of flame and sparks capable of igniting a similar gas air mixture surrounding the enclosure In addition there shall be no mechanical damage to enclosed electrical mechanisms or the enclosure Hydrostatic Test The enclosure shall withstand for 1 minute a hydrostatic test based on the maximum internal explosion pressure developed during the explosion tests as follows cast metal four times the explosion pressure without rupture or permanent deformation fabricated steel twice the explosion pressure without permanent deformation and three times the explosion pressure without rupture Exception Hydrostatic tests may be
204. followed 4 Ventilation passages should be kept open If the equipment depends upon auxiliary cooling e g air water or oil periodic inspection with filter replacement when necessary should be made of these systems 5 The means employed for grounding or insulating the equipment from ground should be checked to assure its integrity see 4 5 6 Accumulations of dust and dirt on all parts including on semiconductor heat sinks should be removed according to the manufacturer s instructions if provided otherwise the manufacturer should be consulted Care must be taken to avoid damaging any delicate components and to avoid displacing dust dirt or debris in a way that permits it to enter or settle into parts of the control equipment 7 Enclosures should be inspected for evidence of deterioration Accumulated dust and dirt should be removed from the top of the enclosures before opening doors or removing covers 8 Certain hazardous materials removed as part of maintenance or repair procedure e g polychlorinated biphenyls PCB found in some liquid filled capacitors must be disposed of as described in Federal regulations Preventive Maintenance Explanatory Information Supplementary Comments Not part of NEMA Standards Publication No ICS 1 1 Lithium batteries are frequently used for memory backup in solid state equipment due to their excellent shelf life and high energy to weight ratio Lithium is a highly reactive
205. for Volts per Hertz Sensorless Vector Vector Control with Force Technology Permanent Magnet Motor Control The control is housed in a separately removable cassette which is the same for all drive ratings simplifying installation and maintenance for the entire product line Optional internal communication modules provide fast and efficient control and or data exchange over the following interfaces DeviceNet ControlNet EtherNet IP PROFIBUS Remote I O Other open control and communication networks PC tools such as DriveExplorer and DriveTools SP to assist with programming monitoring and troubleshooting Phase Il Features 24V dc and 3 24V dc 120V ac Programmable with Configurable for HW Enable 3 Digital Inputs 6 1 2 Open Collector Max Load 750 mA 1 2 1 2 Digital Outputs Relay 24V dc 120V ac 10V dc 0 20 mA Differential Inputs 13 bit sign 0 10V dc Differential Input 10 bit 10V dc 0 20 mA Differential Outputs 11 bit sign 1 5 12V Encoder Input Quadrature Differential Optional Second Encoder DriveLogix I O Compact I O up to 2 racks Option 16 modules Analog Inputs Analog Outputs Encoder Inputs 123 AC Adjustable Frequency Drives PowerFlex 700S Phase II Catalog Number Explanation
206. for Pocket PC This Windows Mobile version works with Pocket PCs such as the Dell Axim and Hewlett Packard iPAQ Connectivity is via serial Wi Fi EtherNet IP and Bluetooth wireless technology Pocket DriveExplorer for Windows CE This Windows CE version works with VersaView CE Integrated Display Computers running Windows CE 3 0 4 1 HPC s such as an HPC Pro using a SH3 processor and a HPC Pro or HPC 2000 using a StrongARM processor Product Selection No of Application Cat No Licenses Pocket DriveExplorer 9306 4PXP01ENE 1 Distribution Media All DriveExplorer versions are distributed on CD ROM in the supported language of English 152 Allen Bradley AC Adjustable Frequency Drives Technical Services and Support Rockwell Automation is committed to maintaining and supporting your Allen Bradley drives and installations This commitment includes support for active products support for products that are no longer manufactured and consultation for high performance drive applications Our Technical Support Center has knowledgeable and experienced specialists who have the expertise equipment and documentation to answer your product questions accurately and efficiently To help minimize the expense of production downtime our call center provides technical assistance weekdays from 7 00 a m to 6 00 p m CST For technical support 24 hours a day 7 days a week a TechConnect support agreement can be
207. for en External DSI Communications Kit DeviceNet Communication Adapter 22 COMM D EtherNet IP Communication Adapter 22 COMM Et PROFIBUS DP Communication Adapter 22 COMM P Compact I O Module 3 Channel 1769 SM2 If NEMA 1 IP30 is required must also order 22 JBCB Frame B drives or 22 JBCC Frame C drives PowerFlex 4 drives require External DSI Communication Kits SK U1 FAN1 A1 Fan Replacement Kit Frame B 1 Fan SK U1 FAN1 B1 Fan Replacement Kit Frame B 2 Fans SK U1 FAN2 B1 Frame A Cover with Power Terminal Guard SK U1 ACVR1 A1 Frame B Cover with Power Terminal Guard SK U1 ACVR1 B1 Frame A Cover Black without Logo SK U1 CVR2 A1 Communication Adapters cannot be drive mounted PC Programming Software Frame B Cover Black without Logo 10 SK U1 CVR2 B1 DriveExplorer Software Description DriveToolsTM SP Software See A B publication 9303 PL002 for ordering pricing information Pocket DriveExplorer Software Allen Bradley AC Adjustable Frequency Drives PowerFlex 4 Input Line Reactors 240V 50 60 Hz Three Phase 3 Impedance Maximum Fundamental Amps Continuous Amps Inductance Watts Loss kw Hp A A mh Ww Cat No 0 2 0 25 2 0 3 0 12 7 5 1321 3R2 A 0 4 0 5 4 0 6 0 12 21 1321 3R4 B 0 75 1 0 8 0 12 3 0 29 1321 3R8 B 1 5 2 0 8 0 12 1 5 19 5 1321 3R8 A 2 8 3 0 12 18 1 25 26 1321 3R12 A 3 7 5 0 18 27 0 8 36 1321 3
208. from the options listed in this publication Engineered options that are listed within this publication will be specified by the heading Engineered Drives Program Only and will have varied lead times Entering a custom quote request for additional options not listed A custom quote will require a Passport quote using SP SDB CUSTOM as the line item part number and entering a description of the base catalog string and custom options in the Competitive Summary For questions or help with a custom quote please contact the Engineered Drives Group at 262 512 8415 Allen Bradley 63 AC Adjustable Frequency Drives PowerFlex 70 Packaged Drives Programs Catalog Number Explanation To interpret the meaning of a catalog number match the values of the catalog number code in positions a b c etc with the tables labeled a b c etc below Position 1 3 4 5 7 8 10 11 12 13 a b C d e f a c3 f Drive Amp Rating 5 Options as required Code Type 480V 60Hz Input Code Description 21A PowerFlex 70 Packaged Code Amps kW Hp BA Auto Bypass Logic Supports the Standard Control version of the 1P1 1 1 0 37 0 5 BM1 Manual Bypass Normal Duty PowerFlex 70 2P1 2 1 0 75 1 0 BM2 Ma
209. g b at Seller s expense Buyer gives Seller the sole right to defend settle and control the defense of the suit or proceeding c Buyer provides all necessary information and assistance for such defense or settlement and d Buyer takes no position adverse to Seller in connection with such claim In the event Seller is obligated to defend such suit or proceeding Seller will pay all costs and damages finally awarded or agreed upon by Seller that are directly related thereto Seller s obligations under this paragraph will be fulfilled if Seller at its option and expense 1 procures for Buyer the right to continue using such Products ii replaces the same with non infringing equipment software having functionality similar to that of the Products iii modifies the Products to make them non infringing while retaining similar functionality or iv if 1 iii are not commercially practicable refunds to Buyer the purchase price of the affected Products in exchange for their return Seller will have no obligation to defend or for any other liability with respect to a any suit or proceeding to the extent based on or arising out of a configuration or modification made specified or requested by Buyer and which is incorporated into or constitutes the Products b the use of the Products in a process or application specified requested or controlled by Buyer or any third parties or c the use of the Products in combination with other equip
210. g table No of Application Cat No Licenses DriveTools32 Suite includes DriveManager32 DriveMonitor32 DrivePanel32 DriveBlockEditor32 DriveTrending32 9303 3CSOEFF 1 DriveTools32 Lite Bundle includes DriveManager32 DriveMonitor32 9303 3CSOE31 1 DrivePanel32 DriveManager32 9303 3CSOE10 1 DriveMonitor32 9303 3CSOE20 1 DrivePanel32 9303 3CSOEO1 1 DriveTrending32 9303 3CSOE80 1 Media DriveTools32 distribution media is CD ROM and the language supported is English Important Refer to publication 9303 BR001B for System Requirements DriveTools for Windows 3 1 The DriveTools software has been packaged so that you can purchase either the entire family or individual software applications within the family In all cases you must own a copy of the DriveManager application as it maintains the drive database and provides the base level of functional support for all products Catalog numbers used for the DriveTools applications are dependent on the specific options selected as shown in the following table Product Selection No of Application Cat No Licenses DriveTools Suite includes DriveManager DriveMonitor DrivePanel DriveBlockEditor DriveTrending 9303 23SOEFF 1 DriveManager 9303 23S0E10 1 DriveMonitor 9303 23S0E20 1 DrivePanel 9303 23S0E01 1 DriveTrending 9303 23S0E80 1 Media The DriveTools applications are compatible with Windows 3
211. hore applications around the world by Lloyd s Register Registoro Italiano Navale Germanischer Lloyd Korean Register of Shipping American Bureau of Shipping Bureau Veritas Det Norske Veritas Compliance with European Union Directives Allen Bradley branded products covered by European Union Directives are intended for sale and use within the European market and conform to the essential requirements of these directives Products specifically required to do so bear the CE marking per the relevant European Union Directives and CE marking regulations Declarations of Conformity for Allen Bradley branded products are available as required at www ab com certification The necessary technical documentation is on file within Rockwell Automation Actual European Union conformity is indicated by the CE Marking on the product or its packaging and not by statements in this catalog or any product literature EU Hazardous Location Certification In addition to the CE mark a limited number of Allen Bradley branded products have also been issued Type Examination Certificates Ex indicating that the products have been found to comply with the Essential Health and Safety Requirements related to their design and construction as Category 1 2 or 3 equipment intended for use in potentially explosive atmospheres as given in Annex II of EU Directive 94 9 EC The related hazardous location protection methods and installat
212. ic Drawings 1301 APPDWG E Black amp Whites 1301 APPDWG Vellums 1301 APPRV As Commissioned Drawings 279 x 432 mm 11 x 17 in One set of schematics Provided after Field Changes are Returned to the Factory Black amp Whites 1301 COMDWG Certified Motor Dimension Drawing 1301 CERMTR Certified Transformer Dimension Drawing 1301 CERXFR Certified Line Reactor Dimension Drawing 1301 CERLR Disk Copy of Final As Shipped Schematics Autocad 2000 1301 DISK Basic Harmonic Analysis Pre order review of customer s one line 1301 HARM1 power distribution diagram Complete Harmonic Analysis Post order detailed harmonic 1301 HARM2 spectrum analysis and a written report Deluxe Harmonic Analysis Post order site verification of actual 1301 HARM3 harmonics detailed spectrum analysis and a detailed written report Witness Test User Viewing of Rockwell Automation Standard Test Procedures 1301 WT Includes viewing Rockwell Automation standard test only Any special requirements must be reviewed by Rockwell Automation for acceptance and possible price changes Allen Bradley 101 AC Adjustable Frequency Drives PowerFlex 700 Packaged Drives Programs Option Selection Reference Guide Required Options Normal Duty or Heavy Duty Power Disconnecting Means Bypass or No Bypass Control Power or No Control Power when dependent options are selected
213. igital Output D2D JM One Digital Output All Other Combinations One Digital Output Requires user supplied control power or the CF option Applies to NEMA Type 1 drives only 5 Requires JF option Allen Bradley AC Adjustable Frequency Drives PowerFlex 70 Packaged Drives Programs Communication Options Enclosures Must Choose One Option Area Option Area Description Code Factor Description amp Approximate Dimensions in mm in Code Factor gt Communication Options Drive Mounted IP 20 NEMA Type 1 Communication Module ControlNet GC AO 667 8 x 220 7 x 293 1 26 3 x 8 7 x 11 5 Style 1 AA1 AO Communication Module DeviceNet GD AO 667 8 x 441 5 x 293 1 26 3 x 17 4 x 11 5 Style 2 AA2 A130 Communication Module Interbus GI AO 667 8 x 662 2 x 293 1 26 3 x 26 1 x 11 5 Style 3 AA3 A360 Communication Module PROFIBUS GP A0 IP 65 NEMA Type 4 12 Indoor AF amp Communication Module Remote 10 GR A0 IP 65 NEMA Type 3 4 Outdoor AH Johnson Controls Metasys Interface Panel Mount GDN2 A20 457 2 x 304 8 x 304 8 18 x 12 x 12 Style 1 AF 7 i 7 457 2 x 406 4 x 304 8 18 x 16 x 12 Style 2 AF Requires user supplied control power or the CF option 558 8 x 406 4 x 304 8 22 x 16 x 12 Style 3 AF Motor Interface Options 812 8 x 330 2 x 304 8 32 x 13 x 12 Style 4 AF AH 812 8 x 609 6 x 406 4 32 x 24 x 16 Style 5 AF AH Area
214. ing and maintaining your Allen Bradley AC and DC drive products Easy to use menus dialogs wizards and graphic displays help you quickly start up your Allen Bradley drive product Powerful diagnostic features simplify diagnosing drive as well as system problems DriveExecutive and DriveTools SP distribution media is CD ROM and the language supported is English DriveTools SP goes beyond the successes of DriveTools32 by offering more user conveniences such as user files that automatically embed necessary database files single communication set up and more built in intelligence DriveTools SP uses RSLinx Lite for communications DriveExecutive DriveExecutive This software is an online offline drive and adapter configuration tool that leverages Windows Explorer style navigation built in html product help and handy diagnostic and setup wizards A state of the art comparison tool lets you look at differences and make two devices files the same DriveObserver Drive Observer This software provides real time chart displays of drive performance to help you set up tune and troubleshoot your drive applications Charts can contain parameters from multiple drives and or adapters from multiple networks as needed Files save data for offline viewing and chart set up for collecting new data later Allen Bradley 149 AC Adjustable Frequency Drives Drives Software DriveTools32 This suite is a family of
215. input line reactor Output line reactors were sized based on the VFD rated output currents 4 impedance Allen Bradley 119 AC Adjustable Frequency Drives PowerFlex 700H Output Line Reactors 600V 60 Hz Three Phase 3 Impedance Output Line Reactor IPOO Open Style IP11 NEMA Type 1 PowerFlex 700H has an integral input line reactor Output line reactors were sized based on the VFD rated output currents 120 Drive Cat No Duty Hp Cat No Cat No 20CD170 Heavy Duty 150 1321 3R160 C 1321 3RA160 C 20CD170 Normal Duty 150 1321 3R200 C 1321 3RA200 C 20CD208 Heavy Duty 150 1321 3R200 C 1321 3RA200 C 20CD208 Normal Duty 200 1321 3R200 B 1321 3RA200 B 20CD261 Heavy Duty 200 1321 3R200 B 1321 3RA200 B 20CD261 Normal Duty 250 1321 3RB250 B 1321 3RAB250 B 20CD325 Heavy Duty 250 1321 3RB250 B 1321 3RAB250 B 20CD325 Normal Duty 350 1321 3RB320 B 1321 3RAB320 B 20CD385 Heavy Duty 350 1321 3RB320 B 1321 3RAB320 B 20CD385 Normal Duty 400 1321 3RB400 B 1321 3RAB400 B 20CD416 Heavy Duty 350 1321 3RB320 B 1321 3RAB320 B 20CD416 Normal Duty 450 1321 3RB400 B 1321 3RAB400 B 20CD460 Heavy Duty 400 1321 3RB400 B 1321 3RAB400 B 20CD460 Normal Duty 450 1321 3R500 B 1321 3RA500 B 20CD502 Heavy Duty 450 1321 3RB400 B 1321 3RAB400 B 20CD502 Normal Duty 500 1321 3R500 B 1321 3RA500 B 20CD590 Heavy Duty 500 1321 3R500 B 1321 3RA500 B 20CD590 No
216. inst minimum resistance for drive being used For 11 and 15 kW 15 and 20 Hp applications use two 7 5 kW 10 Hp size resistors wired in parallel Internal Dynamic Brake Resistor Kits Drive Input Brake Resistance Voltage Q Frame Cat No A 20AB DB1 A 62 B 20AB DB1 B 200 240V ac C 20AB DB1 C 22 D 20AB DB1 D A 20AD DB1 A 115 B 20AD DB1 B 380 480V ac C 20AD DB1 C 62 D 20AD DB1 D A 20AD DB1 A 115 B 20AD DB1 B 600V ac C 20AD DB1 C D Not Available 54 Allen Bradley AC Adjustable Frequency Drives PowerFlex 70 Medium Duty External Dynamic Brake Resistors These resistors provide a larger duty cycle capability than the internal type Includes an internal thermal switch for use in external safety circuit PowerFlex 70 AC Drive Medium Duty External DB Resistor Max Application Type 1 Application Type 2 Min DB Resistance Braking Braking Braking Normal Heavy Res E Continuou Max Torque Torque Torque Duty Duty Ohms Ohms s Power Energy of ND of ND of ND kW Hp kW Hp 10 Part Number 5 kw kJ Motor Motor Duty Cycle Motor Duty Cycle 200 240 Volt AC Input Drives 0 37 0 5 0 25 0 33 33 AK R2 091P500 91 0 086 17 293 100 46 150 31 0 75 1 0 0 55 0 75 33 AK R2 091P500 91 0 086 17 218 100 23 150 15 1 5 2 0 1 1 1 5 33 AK R2 091P500 91 0 086 17 109 100 11 109 11
217. ion IP0_ No test required IP1_ A rigid sphere 50 mm in diameter shall not completely pass through any opening Force 50 N IP2 A jointed test finger 80 mm long and 12 mm in diameter may penetrate to its 80 mm length but shall have adequate clearance as specified above from hazardous live parts in every possible position of the test finger as both joints are bent through an angle up to 90 Force 10 N IP3_ A test rod 2 5 mm in diameter shall not penetrate and adequate clearance shall be kept from hazardous live parts as specified above Force 3 N IP4_ A test wire mm in diameter shall not penetrate and adequate clearance shall be kept from hazardous live parts as specified above Force 1 N IP5_ A test wire 1 mm in diameter shall not penetrate and adequate clearance shall be kept from hazardous live parts as specified on page Important 11 Force 1 N IP6_ A test wire 1 mm in diameter shall not penetrate and adequate clearance shall be kept from hazardous live parts as specified on page Important 11 Force 1 N Tests for Protection Against Solid Foreign Objects first characteristic numeral For first numerals 1 2 3 and 4 the protection against solid foreign objects is satisfactory if the full diameter of the specified probe does not pass through any opening Note that for first numerals 3 and 4 the probes are intended to simulate foreign objects which may be spherical Where sha
218. ion Volts per Hertz Adjustable Voltage Control User Sets Multi Language Adv Drive OL Protection Adv Bus Regulation Adv PID Control Spd or Trq Flux Braking Fast Stop Scale Blocks Droop Analog Trim Invert TorqProve Position Indexing Speed Profiler Adv Flying Start Motor OL Protection Common Bus Capability Parameter Linking Open Motor Lead Detection IP 20 Open 50 C IP 21 NEMA 1 40 C IP 54 Flange 40 C DeviceNet ControlNet Coax ControlNet Fiber EtherNet IP Remote 1 0 RS485 DF1 PROFIBUS DP Interbus Modbus RTU Bluetooth Allen Bradley PowerFlex 700H 200 N A N A 132 560 kW 200 900 HP 110 560 kW 150 800 HP 160 800 kW Volts per Hertz Sensorless Vector Slip Compensation User Sets Multi Language Drive OL Protection Bus Regulation PI Control Speed Droop Analog Trim Flying Start Motor OL Protection IP 21 NEMA 1 Normal Duty 40 C DeviceNet ControlNet Coax ControlNet Fiber EtherNet IP Remote 1 0 RS485 DF1 PROFIBUS DP Interbus LonWorks Modbus RTU Metasys N2 Siemens P1 FLN Bluetooth AC Adjustable Frequency Drives PowerFlex Selection Guide PowerFlex 700S 20D N A 0 75 55 kW 1 100 HP 0 75 800 kW 1 1250 HP 50 800 kW 1 1100 HP 75 1200 kW Vector Control VC w FORCE Technology Sensorless VC Slip Compensation Encoder Speed Control Encoderless Speed Control Torque Regulation Volts per Hertz Perm
219. ion restrictions are documented in the product user documentation See www ab com certification Actual approval of product for use in EU Hazardous classified locations is indicated by the marking on the product and not by statements in this catalog or any product literature DEMKO Certification In addition to the CE mark a limited number of Allen Bradley branded products have DEMKO certification D DEMKO certifies products for general use as well as hazardous locations As a Notified Body for the European Hazardous Location Directives DEMKO verifies that products comply with the applicable European directives and standards for use in hazardous locations Refer to the specific product nameplate for the actual hazardous location rating Actual DEMKO approval of product is indicated by the marking on the product and not by statements in this catalog or any product literature Allen Bradley AC Adjustable Frequency Drives Important Safety and Product Information Australian C Tick Compliance Allen Bradley branded products covered by Australian acts are intended for sale and use within the Australian market and conform with the essential requirements of these acts Declarations of Conformity for Allen Bradley branded products are available as required Actual C Tick conformity is indicated by the label on the product and not by statements in this catalog or any product literature ISO 9001 Registration Rockwell
220. ionally defined Class I Zone 2 Group IIC area classification see IEC publication 60079 10 Therefore products labeled Class I Division 2 Group A B C D may be used in Class I Zone 2 Group IIC environments Actual UL listing is indicated by the marking on the product and not by statements in this catalog or any product literature 161 AC Adjustable Frequency Drives Important Safety and Product Information CSA Certification In many cases Rockwell Automation pursues applicable CSA certifications for its products CSA certifies products for general use as well as for use in hazardous locations Products in this catalog might be certified in one of these two ways CSA Certification CSA The product is certified by the Canadian Standards Association for use in Non hazardous Locations CSA Class I Division 2 Hazardous Location Certification The product is listed by the Canadian Standards Association as certified for use in Class I Division 2 Group A B C D or non hazardous locations Although Rockwell Automation is only using the Class I Division 2 Group A B C D designation on its products it should be noted that this hazardous location classification is equivalent to the internationally defined Class I Zone 2 Group IIC area classification see IEC publication 60079 10 Therefore products labeled Class I Division 2 Group A B C D may be used in Class I Zone 2 Group IIC environments Actual CSA certification
221. isable Mushroom P B 817 Motor Fault Pilot Light Allen Bradley Must select either ND or HD Bypass option BO or B1 Power Disconnecting Means option P1 P2 P3 P4 P6 or P7 and Control Power option C1 or C5 93 AC Adjustable Frequency Drives PowerFlex 700 Packaged Drives Programs PowerFlex 700 Quick Ship Program The Quick Ship Program order entry system has been simplified minimizing the time required to place an order To enter your order type in the first 20 characters of the string and the system will complete the rest Normal Heavy Duty Duty Dimensions Weight Frame Hp Hp Type in Cat No Name Plated Cat No HxWxD kg Ib 21BDO11A6AYNANBONNQS ND BO C1 J2 JA P6 S1 810 813 x 610x422 mm 102 1 9 o jS ST BROT ORY NANEONNGS 13 S9 82 0 x 24 0 x 16 6 in 225 21BD022A6AYNANBONNQS ND BO C1 J2 JA P6 S1 810 813 x 610x422 mm 102 1 1 m 21BDOZZAGAYNANBONNQS S13 S9 82 0 x 24 0 x 16 6 in 225 21 BDO34A6AYNANBONNQS ND BO C1 J2 J4 P6 S1 S10 965 x 610x 422mm 102 1 z 25 ia eS 13 S9 38 0 x 24 0 x 16 6 in 225 21 BDO6SAGAYNANBONNQS ND B0 C1 J2 J4 P6 S1 S10 965 x 762 x 422 mm 127 0 3 a en PIEDUGSAOSONANEDMPIIS 813 89 88 0 x 30 0 x 16 6 in 280 Note Consult factory for orders larger than 1 drive per frame size PowerFlex 700 Packaged Drives Programs How to Order Step 1 Select the basic PowerFlex 700 Drive Catalog Number based on application requirements
222. ix5730 No K DriveLogix Comm Option ControlNet Coax 5 il Controller DriveLogix Comm Option ControlNet Redundant Coax 2 Pu eai with DriveLogix5730 EtherNet IP L DriveLogix Comm Option ControlNet Fiber 8 3 DriveLogix Comm Option ControlNet Redundant Fiber 8 4 DriveLogix Comm Option DeviceNet Open Conn 8 5 DriveLogix Comm Option EtherNet IP Twisted Pair 8 6 Must have the DriveLogix option 8 Requires Expanded Cassette when used with Phase II Control Allen Bradley 145 AC Adjustable Frequency Drives PowerFlex 700S Notes 146 Allen Bradley AC Adjustable Frequency Drives PowerFlex 7000 Medium Voltage Drives Allen Bradley The Allen Bradley PowerFlex 7000 medium voltage drives family incorporates leading edge technology embedded communications and significant commonality across multiple platforms networks operator interface programming and hardware Designed for end users solution providers and OEMs the PowerFlex 7000 air cooled and liquid cooled medium voltage drives meet applications ranging from fractional to 6340kW 8500 hp PowerFlex 7000 medium voltage drives control speed torque direction starting and stopping of standard asynchronous or synchronous AC motors PowerFlex 7000 drives adhere to the most common worldwide standards including NEC IEC NEMA UL and CSA and are available with supply voltages at medium voltage from 2400 6600 volts PowerFlex 7000 medium voltage
223. justable Frequency Drives PowerFlex 40 User Installed Options IP30 NEMA 1 UL Type 1 Conversion Kit Communication Option Kits Description Drive Frame Cat No Description Cat No Field installed kit Converts drive to B 22 JBAB Serial Converter Module RS485 to RS232 IP30 NEMA 1 UL Type 1 enclosure Description Provides serial communication via DF1 Includes conduit box with mounting C 22 JBAC protocol for use with DriveExplorer and DriveExecutive screws and plastic top panel software 22 SCM 232 Field installed kit Converts drive to B 22 JBCB Includes DSI to RS232 serial converter 1203 SFC serial IP30 NEMA 1 UL Type 1 enclosure cable Includes communication option 22 RJ45CBL C20 cable and DriveExplorer Lite CD conduit box with mounting screws c 22 JBCC Serial Cable and plastic top panel Description 2 0 meter serial cable with a locking low profile 1203 SFC connector to connect to the serial converter and a 9 pin sub miniature D female connector to connect a computer Human Interface Module Option Kits and Accessories Null Cable Converter Description For use when connecting the serial converter 1203 SNM Description Cat No to DriveExplorer on a handheld PC LCD Display Remote Panel Mount Digital Speed DSI Cable PANIEL Control CopyCat capable IP66 NEMA Type 4X 12 22 HIM C2S Description 2 0 meter RJ45 to RJ45 cable mal
224. kaged Drives Programs Product Selection 480V ac Three Phase Drives IP54 NEMA Type IP20 NEMA Type 12 less HIM Output Amps Nominal Ratings 1 less HIM w Fan amp Filter 480V ac Input Normal Duty Heavy Duty Cat No Cat No Cont 1 Min 3 Sec Hp Hp Frame Size Positions b d Positions b d 1 1 1 2 1 6 0 5 0 33 0 21BD1P1A 21BD1P1H 2 1 2 4 3 2 1 0 75 0 21BD2P1A 21BD2P1H 3 4 4 5 6 2 1 5 0 21BD3P4A 21BD3P4H 5 5 5 7 5 3 2 0 21BD5POA 21BD5POH 8 8 8 12 5 3 0 21BD8POA 21BD8POH 11 12 1 16 5 7 5 5 0 21BD011A 21BD011H 14 16 5 22 10 7 5 1 21BD014A 21BD014H 22 24 2 33 15 10 1 21BD022A 21BD022H 27 33 44 20 15 2 21BD027A 21BD027H 34 40 5 54 25 20 2 21BD034A 21BD034H 40 51 68 30 25 3 21BD040A 21BD040H 52 60 80 40 30 3 21BD052A 21BD052H 65 78 104 50 40 3 21BD065A 21BD065H 77 65 85 98 116 130 60 50 4 21BD077A 21BD077H 96 77 106 116 144 154 75 60 5 21BD096A 21BD096H 125 96 138 144 163 168 100 75 5 21BD125A 21BD125H 156 125 172 188 233 250 125 100 6 21BD156A 21BD156H 180 156 198 234 270 312 150 125 6 21BD180A 21BD180H 248 180 273 270 372 360 200 150 6 21BD248A 21BD248H Base Drive Catalog Number Includes PowerFlex 700 Drive User Manual Frames 4 5 amp 6 have dual current ratings one for normal duty applications and one for heavy duty applications in parenthesis The drive may be operated at either rating
225. l provides exceptional speed regulation and very high levels of torque across the entire speed range of the drive 3 0 2 5 AE 5 20 2 15 31 0 co E 0 5 0 0 T 1 0 10 20 30 40 50 60 70 80 90 100 Frequency Hz ArmorStart with Sensorless Vector Control 3 Hp High Speed Additional Features 8 Preset Speeds Skip Frequency Flying Start Auto Restart Process Control Loop PID Step Logic Functionality Timer Counter Functions 27 Bulletin 284 ArmorStart Distributed Motor Controllers Description of Features Overload Protection The Bulletin 284 ArmorStart Distributed Motor Controller incorporates as standard electronic motor overload protection This overload protection is accomplished electronically with an Pt algorithm The ArmorStart s overload protection is programmable via the communication network providing the user with flexibility The overload trip class allows for class 10 overload protection Ambient insensitivity is inherent in the electronic design of the overload LED Status Indication The LED Status Indication provides 4 status LEDs and a Reset button The LEDs provide status indication for the following POWER LED The LED is illuminated solid green when control power is present and with the proper polarity RUN LED This LED is illuminated solid green when the motor is running NETWORK LED This bicolor red green LEDs indica
226. ley AC Adjustable Frequency Drives PowerFlex 70 Contents Conformity to Standard Product Packaged Product Standards this page this page Description this page page 63 Catalog Number Explanation page 46 page 64 Product Selection page 49 page 66 User Installed Options page 53 Isolation Transformers page 61 page 61 Input amp Output Line Reactors page 56 page 56 Factory Installed Options page 62 page 68 Quick Ship Program page 65 Conformity to Standards The PowerFlex 70 conforms to the following Conformity to UL Listed Standard Product Packaged Product Y CSA Certified c UL Y IEC Designed to Meet CE Approved excluding 600V C Tick excluding 600V x SJAJ 8 NSF Certified IP66 NEMA Type 4X 12 only v T V Certified v Certified to EN 954 1 Category 3 for 240V 400V and 480V ratings of PowerFlex 70 Enhanced Control with DriveGuard Safe Off option TUV Approved to EN 954 1 Enhanced Control with Allen Bradley Category 3 for 600V ratings of PowerFlex 70 DriveGuard Safe Off option PowerFlex 70 AC Drive Drive Description PowerFlex 70 drives are designed to worldwide standards and ratings allowing out of the box performance around the globe Available ratings include 0 5 to 25 Hp output at 240V ac input 0 5 to 50 Hp output at 480V ac input 0 5 to 50 Hp output at 600V ac input The Pow
227. lus Drive Start Up With ProtectionPlus Drive Start Up Services from Rockwell Automation users can leverage the extensive product and industry experience of Rockwell Automation technicians to quickly commission drives and reduce the time between integration and actual start up ProtectionPlus Drive Start Up Services verify drive installation to ensure proper electrical mechanical and environmental criteria are met This includes verification of power and I O wiring to the drive custom drive configuration tuning to meet application specific requirements and diagnosing troubleshooting problems that occur during a standalone drive start up ProtectionPlus can also extend an eligible product parts warranty and add a labor warranty For more information about ProtectionPlus Drive Services contact your local Rockwell Automation sales office or authorized distributor or visit http support rockwellautomation com SupportPrograms SupportPlus For consultation on high performance drive applications the SupportPlus program is offered SupportPlus uses expert level Rockwell Automation system engineers to support the user s engineering team SupportPlus engineers will work with the end user to layout the appropriate architecture configure drives recommend programming techniques and provide application assistance on the most effective ways to implement the control solution For more information please call 262 512 8176 or refer to www ab com sup
228. mal Duty 30 1321 3R45 B 1321 3RA45 B 1321 3R45 B 1321 3RA45 B 20BD052 Heavy Duty 30 1321 3R45 B 1321 3RA45 B 1321 3R55 B 1321 3RA55 B 20BD052 Normal Duty 40 1321 3R55 B 1321 3RA55 B 1321 3R55 B 1321 3RA55 B 20BD065 Heavy Duty 40 1321 3R55 B 1321 3RA55 B 1321 3R80 B 1321 3RA80 B 20BD065 Normal Duty 50 1321 3R80 B 1321 3RA80 B 1321 3R80 B 1321 3RA80 B 20BD077 Heavy Duty 50 1321 3R80 B 1321 3RA80 B 1321 3R80 B 1321 3RA80 B 20BD077 Normal Duty 60 1321 3R80 B 1321 3RA80 B 1321 3R80 B 1321 3RA80 B 20BD096 Heavy Duty 60 1321 3R80 B 1321 3RA80 B 1321 3R80 B 1321 3RA80 B 20BD096 Normal Duty 75 1321 3R100 B 1321 3RA100 B 1321 3R100 B 1321 3RA100 B 20BD125 Heavy Duty 75 1321 3R100 B 1321 3RA100 B 1321 3R100 B 1321 3RA100 B 20BD125 Normal Duty 100 1321 3R130 B 1321 3RA130 B 1321 3R130 B 1321 3RA130 B 20BD156 Heavy Duty 100 1321 3R130 B 1321 3RA130 B 1321 3R130 B 1321 3RA130 B 20BD156 Normal Duty 125 1321 3R160 B 1321 3RA160 B 1321 3R160 B 1321 3RA160 B 20BD180 Heavy Duty 125 1321 3R160 B 1321 3RA160 B 1321 3R160 B 1321 3RA160 B 20BD180 Normal Duty 150 1321 3R200 B 1321 3RA200 B 1321 3R200 C 1321 3RA200 C 20BD248 Heavy Duty 150 1321 3R200 B 1321 3RA200 B 1321 3R200 C 1321 3RA200 C 20BD248 Normal Duty 200 1321 3RB250 B 1321 3RAB250 B 1321 3RB250 B 1321 3RAB250 B Input line reactors were sized based on the NEC fundamental motor amps Output line reactors were sized based on the VFD rated output currents 86 Allen Bradley AC Adjustable Frequency Drives
229. mal Duty 30 1321 3R80 B 1321 3RA80 B 1321 3R80 B 1321 3RA80 B 20BB104 Heavy Duty 30 1321 3R80 B 1321 3RA80 B 1321 3R80 B 1321 3RA80 B 20BB104 Normal Duty 40 1321 3R100 B 1321 3RA100 B 1321 3R100 B 1321 3RA100 B 20BB130 Heavy Duty 40 1321 3R100 B 1321 3RA100 B 1321 3R100 B 1321 3RA100 B 20BB130 Normal Duty 50 1321 3R130 B 1321 3RA130 B 1321 3R130 B 1321 3RA130 B 20BB154 Heavy Duty 50 1321 3R130 B 1321 3RA130 B 1321 3R130 B 1321 3RA130 B 20BB154 Normal Duty 60 1321 3R160 B 1321 3RA160 B 1321 3R160 B 1321 3RA160 B 20BB192 Heavy Duty 60 1321 3R160 B 1321 3RA160 B 1321 3R160 B 1321 3RA160 B 20BB192 Normal Duty 75 1321 3R200 B 1321 3RA200 B 1321 3R200 B 1321 3RA200 B 20BB260 Heavy Duty 75 1321 3R200 B 1321 3RA200 B 1321 3R200 B 1321 3RA200 B 20BB260 Normal Duty 100 1321 3RB250 B 1321 3RAB250 B 1321 3RB250 B 1321 3RAB250 B Input line reactors were sized based on the NEC fundamental motor amps Output line reactors were sized based on the VFD rated output currents Allen Bradley 85 AC Adjustable Frequency Drives PowerFlex 700 Input and Output Line Reactors 480V 60 Hz Three Phase 3 Impedance Input Line Reactor Output Line Reactor IPOO Open Style IP11 NEMA Type 1 IPOO Open Style IP11 NEMA Type 1 Drive Cat No Duty Hp Cat No Cat No Cat No Cat No 20BD1P1 Heavy
230. ment software or materials not supplied by Seller As used in this paragraph the term Products shall mean only Seller s standard hardware and software that are generally commercially available and expressly excludes third party branded equipment software THIS PARAGRAPH IS IN LIEU OF ALL WARRANTIES OR REPRESENTATIONS WHETHER EXPRESS OR IMPLIED THAT THE PRODUCTS WILL BE FREE OF THE RIGHTFUL CLAIM OF ANY THIRD PARTY BY WAY OF INFRINGEMENT OR THE LIKE Resale of Third Party Branded Products and Services NOTWITHSTANDING ANY OTHER PROVISION HEREIN SELLER MAKES NO REPRESENTATIONS PROVIDES NO INDEMNITIES INTELLECTUAL PROPERTY OR OTHERWISE AND DISCLAIMS ALL WARRANTIES OF ANY KIND EXPRESS OR IMPLIED RELATIVE TO ANY THIRD PARTY BRANDED PRODUCT OR SERVICE INCLUDING TRAINING WHICH MAY BE RESOLD OR SUBLICENSED BY SELLER AS A DISCRETE ITEM HEREUNDER 158 Licensed Software and Firmware Use of Products comprised of software or firmware may be subject to Buyer s acceptance of additional terms and conditions set forth in separate Seller or third party license agreements that will control to the extent necessary to resolve any conflict with the terms and conditions stated or otherwise referenced herein In the absence of a separate Seller s license agreement Buyer is granted a non exclusive non transferable license to use provided Seller s software or firmware only in object code form and solely in conjunction with Seller pro
231. metal that can cause burns if there is contact with skin The batteries are sealed so there is seldom a problem of contact with lithium as long as reasonable care is exercised when handling them They should only be used in their intended application and not subjected to rough handling When batteries are replaced in equipment the batteries removed should be disposed of in accordance with the battery supplier s instructions The Department of Transportation has certain regulations that prohibit shipment of equipment with batteries installed if the batteries contain 0 5 grams or greater of lithium The batteries must be removed from equipment and shipped separately in a container approved by the Department of Transportation Additional Department of Transportation restrictions apply to the shipment of lithium batteries NEMA Standards Publication No ICS 1 3 1986 Preventive Maintenance of Industrial Control and System Equipment is recommended for personnel responsible for maintenance of equipment Allen Bradley AC Adjustable Frequency Drives Important Safety and Product Information 5 3 Repair If equipment condition indicates repair or replacement the manufacturer s instruction manual should be followed carefully Diagnostic information within such a manual should be used to identify the probable source of the problem and to formulate a repair plan The level of field repair recommended by the manufacturer should be followed
232. n Communication 1 O Options Catalog Code Option Description Position 12 Description Code RS485 Standard 4 DeviceNet VO 4 In 2 Out w Spring Return HOA and Power R3 DeviceNet D Disconnect Aux Contact EtherNet IP E DeviceNet Point I O w IB4 4 Inputs R4 PROFIBUS DP P P3 plus 4 I O Quick Disconnect 0 05 MM Power Disconnect Means Enclosure Options Description Option Code Description as Motor cleus Protector P3 DeviceNet Quick Disconnect Bottom E22 a Ee DeviceNet Quick Disconnect Side E23 If option P3 or P6 is not selected branch circuit protection must be ee supplied by user Operator Devices Door Mounted Description Option P B Pushbutton S S Selector Switch P L Pilot Light Code H O A S S Start Stop Spd Ref S1 Auto Manual S S Speed Ref S4 Start and Stop PB S7 Forward Reverse S8 Local Control with Off Run Forward and a Local Remote S S S20 Local Off Remote with N O Interposing Relay S21 Allen Bradley 23 AC Adjustable Frequency Drives PowerFlex 40 Packaged Drives Programs Codes and Standards Code Standard UL c UL CSA MO UL508C U CSA C 22 2 No 14 This program provides UL listed from the factory as standard E European Conformance Standard C LV FEE ae 0178 EN N EMC Directive 89 336 EEC EMC EN 61800 3 This program meets CE directives noted C Tick EN 61800 3 This program meets C Tick directives
233. ncy Drives PowerFlex Drive Packages for Fan amp Pump Applications Overview The Packaged Product program allows users to create Disconnect and Contactor Bypass packages based on their specific needs and requirements A limited factory installed option set is offered to optimize package configurations while providing a versatile and cost effective solution All configurations feature wall mount NEMA Type 1 packaging The program has two levels Standard Packaged Drives The Standard Packaged Drives Program allows users to create drive packages based on their specific needs A complete drive package may be specified by assembling a single catalog number string that includes a base drive and all required options Packaging is available for 208V 480V and 600V systems in NEMA Type 1 enclosures The program consists of a fully defined catalog string identified within this price sheet Three packaged configurations are offered which provide consistent manufacturing and minimize customer resources by reducing engineering manufacturing and installation time Typical delivery is 20 business days from order entry and can be ordered through the Passport order entry system Engineered Drives The Engineered Drives Program offers users the ability to create drive packages beyond the Standard Packaged Drives offering Options may or may not be defined within this publication Product can be ordered by Assembling a catalog string from the options liste
234. nd installation time Product can be ordered through the order entry system Engineered Drives The Engineered Drives Program offers users the ability to create drive packages beyond the Standard Packaged Drives offering Product can be ordered by entering a custom quote request for additional options not listed A custom quote will require a Passport quote using SP SDB CUSTOM as the line item part number and entering a description of the base catalog string and custom options in the Competitive Summary For questions or help with a custom quote please contact the Engineered Drives Group at 262 512 8415 PowerFlex 40 Packaged Drives Programs How to Order Step 1 Select the basic PowerFlex 40 Drive Catalog Number based on application requirements nominal HP Step 2 Specify Options The following pages list and describe the available options The listing is divided into simple categories to assist in quickly locating specific needs Some options are horsepower and or voltage specific or will have special rules associated with them Read all Footnotes Example An application requires a variable speed control for an existing 3 HP 480V ac conveyor motor Both drive and motor will be located in a wash down environment Drive mounted keypad is required for programming RS485 for communication a system disconnect providing branch circuit protection and Hand Off Auto Description Cat No Code Posi
235. ndamental motor amps Output line reactors were sized based on the VFD rated output currents Input and Output Line Reactors 240V 60 Hz Three Phase 5 Impedance Input Line Reactor Output Line Reactor IPOO Open Style IP11 NEMA Type 1 IPOO Open Style IP11 NEMA Type 1 Drive Cat No Duty Hp Cat No Cat No Cat No Cat No 20AB2P2 Heavy Duty 0 33 1321 3R2 A 1321 3RA2 A 1321 3R2 A 1321 3RA2 A 20AB2P2 Normal Duty 0 5 1321 3R2 A 1321 3RA2 A 1321 3R2 A 1321 3RA2 A 20AB4P2 Heavy Duty 0 75 1321 3R4 B 1321 3RA4 B 1321 3R4 B 1321 3RA4 B 20AB4P2 Normal Duty 1 0 1321 3R4 B 1321 3RA4 B 1321 3R4 B 1321 3RA4 B 20AB6P8 Heavy Duty 1 5 1321 3R8 B 1321 3RA8 B 1321 3R8 B 1321 3RA8 B 20AB6P8 Normal Duty 2 0 1321 3R8 B 1321 3RA8 B 1321 3R8 B 1321 3RA8 B 20AB9P6 Heavy Duty 2 0 1321 3R8 B 1321 3RA8 B 1321 3R12 B 1321 3RA12 B 20AB9P6 Normal Duty 3 0 1321 3R12 B 1321 3RA12 B 1321 3R12 B 1321 3RA12 B 20AB015 Heavy Duty 3 0 1321 3R12 B 1321 3RA12 B 1321 3R18 B 1321 3RA18 B 20AB015 Normal Duty 5 0 1321 3R18 B 1321 3RA18 B 1321 3R18 B 1321 3RA18 B 20AB022 Heavy Duty 5 0 1321 3R18 B 1321 3RA18 B 1321 3R25 B 1321 3RA25 B 20AB022 Normal Duty 1 5 1321 3R25 B 1321 3RA25 B 1321 3R25 B 1321 3RA25 B 20AB028 Heavy Duty 7 5 1321 3R25 B 1321 3RA25 B 1321 3R35 B 1321 3RA35 B 20AB028 Normal Duty 10 1321 3R35 B 1321 3RA35 B 1321 3R35 B 1321 3RA35 B 20AB
236. ndards Code Standard Action CE C Consult the factory with European Conformance requirements to meet the Standard separate Low Voltage and or EMC directives Provide a one line power IEEE519 distribution drawing and the Harmonic Distortion Levels associated specification to the factory for review This program provides UL panel t UL US recognition from the factory as standard UL c UL CSA Engineered Drives Program Only Allen Bradley AC Adjustable Frequency Drives PowerFlex 700 Packaged Drives Programs Drawing and Test Options For Standard Packaged Drives Only Description One Set of Cat No Manufacturing Drawings 279 x 432 mm 11 x 17 in One set of schematics Information Only Manufacture Proceeding Not to be used as Approval Drawings Diskette 1301 MFDISK Electronic Drawings 1301 MFDWG E Black amp Whites 1301 MFDWG Vellums 1301 MFRV Final Drawings as shipped 279 x 432 mm 11 x 17 in One set of schematics Copy of Drawings that Shipped with the Job Diskette 1301 FINDISK Electronic Drawings 1301 FINDWG E Black amp Whites 1301 FINDWG Vellums 1301 FINRV Mylar 1301 FINRM Test Report Drive Only 1301 TESTR Engineered Drives Program Only Approval Drawings 279 x 432 mm 11 x 17 in One set of schematics Manufacture Held Until Approved Prints are Received Diskette 1301 APPDISK Electron
237. ne for normal duty applications and one for heavy duty applications in parenthesis The drive may be operated at either rating 650V dc Input Drives 650V dc Input 540V dc Input IP20 NEMA Type 1 Output Amps Normal Heavy Output Amps Normal Heavy DC Pre Cat No Frame Cort 1 Min 3 Sec Duty Hp Duty Hp Cont 1 Min 3 Sec Duty kW Duty kW charge 20D Size 96 77 106 116 144 154 75 60 105 85 116 128 158 170 55 45 N JO96A0ENNANANE 5 96 77 106 116 144 154 75 60 105 85 116 128 158 170 55 45 Y RO96A0ENNANANE 5 125 96 138 144 163 168 100 75 125 96 138 144 163 168 55 45 N J125A0ENNANANE 5 125 96 138 144 163 168 100 75 125 96 138 144 163 168 55 45 Y R125A0ENNANANE 5 156 125 172 188 233 250 125 100 170 140 187 210 255 280 90 75 N J156A0ENNANANE 6 156 125 172 188 233 250 125 100 170 140 187 210 255 280 90 75 Y R156A0ENNANANE 6 180 156 198 234 270 312 150 125 205 170 220 255 289 313 110 90 N J180A0ENNANANE 6 180 156 198 234 270 312 150 125 205 170 220 255 289 313 110 90 Y R180A0ENNANANE 6 248 180 gt 273 270 372 360 200 150 260 205 gt 286 308 390 410 132 110 N J248A0ENNANANE 6 248 180 gt 273 270 372 360 200 150 260 205 gt 286 308 390 410 132 110 Y R248A0ENNANANE 6
238. noted Refer to the PowerFlex 40 User Manual publication 22B UMO01 Option Selection Reference Guide Option Must Be Used With Cannot Be Used With Voltage Only one can be selected Current Rating Only one can be selected Enclosure Type Only one can be selected Interface Module Only one can be selected Emission Class Only one can be selected Version Only one can be selected 4 D E or P E22 D Position 12 4 E P Position 12 E23 E23 D Position 12 4 E P Position 12 E22 P3 P6 P6 P3 R3 D Position 12 4 E P Position 12 R4 R5 S1 S4 S7 S8 S20 S21 R4 D Position 12 4 E P Position 12 R3 R5 R5 D Position 12 C Position 9 4 E P Position 12 R3 R4 S1 S4 S7 S8 S20 S21 S1 R3 R5 S4 S7 S20 S21 S4 R3 R5 S1 S20 S21 S7 R3 R5 S1 S20 S21 S8 R3 R5 S20 S21 S20 end e R3 R5 S1 S4 S7 S8 S21 S21 R3 R5 S1 S4 S7 S8 S20 24 Allen Bradley AC Adjustable Frequency Drives PowerFlex 40 Packaged Drives Programs Dimensions Frame B di 15 98 203 2 da r 9 TEN 36 6
239. ntrol Relay i 5 10 Maximum continuous rating for Normal Duty JF Drive Fault Control Relay Must b ified i ue e Spec drives JM Alarm Control Relay Maximum continuous rating for Normal Duty drives d JR Drive Run Control Relay Enclosure x JT At Speed a Relay c2 Code Enclosure a we en Amp Rating 6 AAI IP 20 NEMA Type 1 Style 1 uitput Contactor p g LQN Output Line Reactor Normal Duty 240V 60Hz Input AA2 IP 20 NEMA Type 1 Style 2 LQH Output Line Reactor Heavy Duty Code Amps kW Hp AA3 IP 20 NEMA Type 1 Style 3 LRN Input Line Reactor Normal Duty 2p2 22 0 37 0 5 AF IP65 NEMA Type 4 12 Indoor 3 3 LRH Input Line Reactor Heavy Duty 4P2 42 0 75 1 0 AH IP65 NEMA Type 3 4 Outdoor z 2 Must be specified ME Drive Bypass Motor Run Time Meter 6P8 6 8 1 5 2 0 MH Motor Heater Control Remote Power SIRE 9 6 22 8 0 e N1 Analog Input Isolator 0 10V 015 15 3 4 0 5 0 HIM N2 Analog Input Isolator 4 20mA 022 22 5 5 7 5 Code Interface Module N3 Analog Output Isolator 0 10V 028 28 7 5 10 HO Blank HIM NP No Drive Input Protection gt hin E pis NEN H1 Digital LED HIM PR1 Prog Relay Qty 1 8 on continuous rating for Normal Duty H2 Digital LCD HIM PR Prog Relay Qty 1 H3 Full Numeric LCD HIM H4 Analog LCD HIM H5 Prog Only LCD HIM C3 Full Numeric LCD 4 12 Indoor C5 Prog Only LCD 4 12 Indoor 64 Must be specified wy Allen Bradley AC Adjustable Frequency Drives PowerFlex
240. nual Bypass Heavy Duty 3P4 3 4 1 5 2 0 BR Drive Mounted Brake Resistor b 5PO 5 0 2 2 3 0 CB Input Circuit Breaker Voltage Rating 8P0 8 0 4 0 5 0 CF 115V Control Power Code Voltage Ph 011 11 5 5 7 5 DS Input Fused Disconnect Switch B 240V ack 3 014 14 7 5 10 DIA Hand Off Auto D 480V acx 3 022 22 11 15 D2A Drive Run P L E 600V act 3 027 27 15 20 D2B Drive Fault P L X 208V acx 3 Must be specified D2C At Speed PL 400V act 3 Maximum continuous rating for Normal Duty D2D Drive Alarm P L Supports the Standard Control version of the drives D3A Control Power On P L PowerFlex 70 c4 D4A Drive Mode P L amp Bypass Mode P L Must be specified D4B Auto Bypass Enable On P L amp Bypass Custom quote required Amp Rating 5 Mode PLL 600V 60Hz Input D5A Drive Disable M H P B c1 Code Amps kW Hp D6A Motor Fault Pilot Light NUBHHGUE 0P9 0 9 0 37 0 5 ET Nameplate Door Mounted mp Rating a em z 1P7 1 7 0 75 1 0 FASP Fire Alarm 8 Smoke Purge Logic EE Fr TT 2P7 27 1 5 2 0 FB Input Fusing TEL gt S os 3P9 3 9 2 2 3 0 GC ControlNet Comm Module AED 48 075 A 0 6P1 6 1 4 0 5 0 GD DeviceNet Comm Module 9P0 9 0 5 5 7 5 GDN2 Johnson Controls Metasys Interface 6P8 7 8 1 5 2 0 011 11 7 5 10 5 10 Gl Interbus Comm Module 9P6 11 2 2 3 0 E T 1060 017 17 11 15 GP Profibus Comm Module 022 22 15 20 GR RIO Comm Module 022 25 3 5 5 7 5 m e 528 E FENO Must be specified JC Control Power On Co
241. o Size 2 2 2 4 3 3 0 5 0 33 2 5 2 8 3 8 0 37 20BB2P2A0AYNBNCO 0 4 2 4 8 6 4 1 0 75 4 8 5 6 7 0 75 0 37 20BB4P2A0AYNBNCO 0 6 8 9 12 2 1 5 7 8 10 4 13 8 1 5 0 75 20BB6P8A0AYNBNCO 1 9 6 10 6 14 4 3 2 11 12 1 17 2 2 1 5 20BB9PGADAYNBNCO 1 15 3 16 8 23 5 3 17 5 19 3 26 3 4 2 2 20BB015A0AYNBNCO 1 22 24 2 33 7 5 5 25 3 27 8 38 5 5 4 20BB022A0AYNBNCO 1 28 33 44 10 7 5 32 2 38 50 6 7 5 5 5 20BB028A0AYNBNCO 2 42 46 2 63 15 10 48 3 53 1 72 5 11 7 5 20BB042A0AYNBNCO 3 52 63 80 20 15 56 64 86 15 11 20BB052A0AYNBNCO 3 70 78 105 25 20 78 2 86 117 3 18 5 15 20BB070A0ANNANCO 4 80 105 136 30 25 92 117 3 156 4 22 18 5 20BB080A0ANNANCO 4 104 80 115 120 175 160 40 30 120 92 132 138 175 175 30 22 20BB104A0ANNANCO 5 130 104 143 156 175 175 50 40 130 104 143 156 175 175 37 30 20BB130A0ANNANCO 5 154 130 169 195 231 260 60 50 177 150 195 225 266 300 45 37 20BB154A0ANNANCO 6 192 154 211 231 288 308 75 60 221 177 243 266 308 308 55 45 20BB192A0ANNANCO 6 260 205 286 305 390 410 100 75 260 205 286 305 390 410 66 55 20BB260A0ANNANCO 6 Catalog number corresponds to output amps in these columns Drive must be programmed to lower voltage to obtain higher currents shown at right Frame 5 and 6 drives have dual current ratings one for normal duty applications and one for heavy duty applications in parenthesis The drive may be operated at either rating 380
242. ol Expanded Yes Yes D 208 240V ac 1 7 5 Hp 22 Y Sim NIA ha e Y Slim N A Yes H 1 115 Y 380 480V ac 2 62 Y All N Feedback Options Cat Code Internal EMC Filter Description Position None N cesse Resolver 10 26V 10 kHz 10 16 bit A Drive Input Voltage CE Filter Frame Pestini Stegman High Resolution Encoder Hyperface 8 5V DC 20 208 240V ac Standard 1 6 A bit 100k r B 380 480V ac Standard 1 6 A Multi Device Interface for Stegmann or Linear Temposonics C 380 500V ac No 9 N 380 500V ac Standard 98 Up B 2nd Encoder 5V or 12V Configurable by the Drive E 600 690V ac Standard 1 6 A Drive Guard Safe Off w 2nd Encoder S For use on ungrounded distribution systems Requires Expanded Cassette when used with Phase II Control For use with Phase Control ONLY For use with Phase Il Control Only Internal Communication Adapters Additional Configurations Cat Code Cat Code Description Position j Embedded None N Description Communication Position m ControlNet Coax Communication Adapter DPI C ae WA N DeviceNet Communication Adapter DPI D PIERE Dias en Manon N A A EtherNet IP Communication Adapter DPI E Phase Control with DriveLogix5720 m E ControlNet Fiber Communication Adapter DPI Q Controller 768k bytes of User Memory Remote I O Communication Adapter DPI R Phase II Control No E RS 485 DF1 Communication Adapter DPI S Phase II Control with DriveLog
243. omitted if calculations show safety factor of 5 1 for cast metal and 4 1 for fabricated steel Temperature Test The enclosed device is subjected to a temperature test to determine maximum temperature at any point on the external surface The device must be marked with a temperature code based on the result only if the temperature exceeds 212 F 100 C Dust Penetration Test The device is operated at full rated load until equilibrium temperatures are attained then allowed to cool to ambient room temperature through six heating and cooling cycles covering at least 30 hours while continuously exposed to circulating dust of specified properties in a test chamber No dust shall enter the enclosure Temperature Test with Dust Blanket This test is conducted as described for the Dust Penetration test except that the recirculating dust nozzles are positioned so that the dust is not blown directly on the device under test The device is operated at full rated load and under abnormal conditions for equipment subject to overloading until equilibrium temperatures are attained Dust in contact with the enclosure shall not ignite or discolor from heat and the exterior temperatures based on 104 F 40 C ambient shall not exceed Group Normal Operation Abnormal Operation E 392 F 200 C 392 F 200 C F 302 F 150 C 392 F 200 C G 248 F 120 C 329 F 165 C Degree of Protection IEC Publica
244. ont 1 Min 2 Sec Duty Hp Duty Hp Cont 1 Min 2 Sec Duty kW Duty kW 20CE 600V Frame Size 170 144 187 216 245 245 150 150 170 144 187 216 245 245 160 132 170A0ANNBNNO 9 208 170 230 250 289 289 200 150 208 170 230 250 289 289 200 160 208A0ANNBNNO 9 261 208 287 312 375 375 250 200 261 208 287 312 375 375 250 200 261A0ANNBNNO 10 325 261 358 392 470 470 350 250 325 261 358 392 470 470 315 250 325A0ANNBNNO 10 385 325 424 488 585 585 400 350 385 325 424 488 585 585 355 315 385A0ANNBNNO 10 416 325 458 488 585 585 450 350 416 325 t 458 488 585 585 400 315 416A0ANNBNNO 10 460 385 506 578 693 693 450 400 460 385 506 578 693 693 450 355 460A0ANNBNNO 11 502 460 552 690 828 828 500 450 502 460 552 690 828 828 500 450 502A0ANNBNNO 11 590 502 649 753 904 904 600 500 590 502 649 753 904 904 560 500 590A0ANNBNNO 11 650 690 715 885 1062 1062 700 650 650 590 715 885 1062 1062 630 560 650A0ANNBNNO 12 750 650 825 975 1170 1170 800 700 750 650 825 975 1170 1170 710 630 750A0ANNBNNO 12 820 750 902 975 1170 1170 900 700 820 750 902 975 1170 1170 800 630 820A0ANNBNNO 12 These drives have dual current ratings one for normal duty applications and one for heavy duty applications in parenthesis The drive may be operated at either
245. ormance for both induction and permanent magnet motors Compact Space Saving Design The PowerFlex family offers a compact Zero Stacking M design allowing side by side mounting to optimize panel space With a variety of enclosure and package options PowerFlex drives are able to meet your specific application requirements Advanced Communications Capabilities To help you gain the most from your automation investment PowerFlex drives utilize an open network architecture to integrate your manufacturing process from shop floor to top floor PowerFlex drives provide common features and services for DeviceNet ControlNet and EtherNet IP networks as well as supporting PROFIBUS InterBus Universal Remote I O and RS485 DF1 Common Operator Interface and Programming Featuring an advanced common operator interface PowerFlex drives reduce training and simplify operation With a consistent programming structure common PC tools for programming monitoring and troubleshooting consistent parameter names and descriptions PowerFlex drives reduce set up time and costs Choice Value and Support And because the PowerFlex family is from Rockwell Automation you can be sure these world class solutions come backed by world leading service and support maximizing your automation investment now and in the future 2 Allen Bradley AC Adjustable Frequency Drives 7000 Po wer OX O Allen Bradley Powerflex mm Tum LI A amp
246. ormed on 600V class drives Release pending at date of printing Verify before ordering d Enclosure Code Enclosure A IP20 NEMA Type 1 N Open IPO0 F 36 IP54 NEMA Type 12 Frames 9 amp up Only 3 Frames 5 amp 6 pending e HIM Code Operator Interface 0 Blank Cover 2 Digital LCD 3 Full Numeric LCD 5 Prog Only LCD C Full Numeric LCD Door Mount Frames 10 amp up only Allen Bradley g Brake Code w Brake IGBT 1 Y Yes N No Brake IGBT is standard on Frames 1 3 and optional on Frames 4 9 ONLY h Brake Resistor Code w Resistor Y Yes N No Not available for Frame 3 drives or larger i Emission Code CE Filter CM Choke A de Yes Yes B gt Yes No NS No No Frames 1 6 Only gt Frames 9 amp up Only 8 For use on ungrounded distribution systems Frame 9 drives only J Comm Slot Code Version N None C DPI ControlNet Coax D DPI DeviceNet E DPI EtherNet IP Q DPI ControlNet Fiber R DPI RIO S DPI RS 485 DF1 1 DriveLogix ControlNet Coax 2 DriveLogix ControlNet Redundant Coax 3 DriveLogix ControlNet Fiber 4 DriveLogix ControlNet Redundant Fiber 5 DriveLogix DeviceNet Open Conn 6 DriveLogix EtherNet IP k Control Options Gode Sonne Lome cassette A io No No Expanded B iis No Yes Expanded C m Yes No Expanded D iud Yes
247. osition g ControlNet Fiber Q 208 600V ac Standard B C Dy E Y Remote I O R 208 600V ac Optional 4 Ye RS 485 DF1TM S 208 600V ac Optional 5 Y No Adapter N 208 600V ac Optional 6 hi PowerFlex 700 options only Control and I O Options Cat Code Control Frame Position k Enhanced Control without DriveGuard B C D E E Standard Control with 24V DC AC VO ae A PowerFlex 700 options only Feedback Option Cat Code Description Position None 0 110 Allen Bradley AC Adjustable Frequency Drives PowerFlex Drive Packages for Fan amp Pump Applications Drawing Options Engineered Drives Program Only Description One Set of Manufacturing Drawings 279 x 432 mm 11 x 17 in One set of schematics Information Only Manufacture Proceeding Not to be used as Approval Drawings Cat No Diskette 1301 MFDISK FP Electronic Drawings 1301 MFDWG E FP Black amp Whites 1301 MFDWG FP Final Drawings as shipped 279 x 432 mm 11 x 17 in One set of schematics Copy of Drawings that Shipped with the Job Diskette 1301 FINDISK FP Electronic Drawings 1301 FINDWG E FP Black amp Whites 1301 FINDWG FP Approval Drawings 279 x 432 mm 11 x 17 in One set of schematics Manufacture Held Until Approved Prints are Received Diskette 1301 APPDISK FP Electronic Drawings 1301 APP
248. oubleshooting the PowerFlex 700H 115 AC Adjustable Frequency Drives PowerFlex 700H Catalog Number Explanation Position 1 3 4 5 7 8 9 10 11 12 13 14 15 16 20C D 261 A A Y N B N N 0 a b C d e f g h i j k a 03 f Drive NDRaing Documentation Code Type 600V 60Hz Input Code Type 20C PowerFlex 700H Code Amps ND HD Hp ND HD A User Manual 170 170 144 150 150 208 208 170 200 150 b 261 261 208 250 200 g 325 325 261 350 250 Brake Voltage Rating 385 385 325 400 350 Code w Brake IGBT Code Voltage Ph 416 416 325 450 350 Y Yes c 400V ac 3 460 460 385 450 400 N No D oe 2 502 502 460 500 450 Brake IGBT is available on Frame 9 drives E 600V ac 3 590 590 502 600 500 only F 690V ac 3 650 650 590 700 650 750 750 650 800 700 820 820 750 900 700 h c1 Brake Resistor ND Rating c4 Code w Resistor 400V 50Hz Input ND Rating N No Code Amps ND HD kW ND HD 690V 50Hz Input 261 261 205 132 110 Code Amps ND HD kW ND HD 300 300 245 160 132 170 170 144 160 132 i 385 385 800 200 160 208 208 170 200 160 Emission 460 460 385 250 200 261 261 208 250 200 Code CM Choke 500 500 420 250 250 325 325 261 315 250 B Yes No 590 590 520 315 250 385 385 325 355 815 N No No 650 650 590 355 315
249. pe of the entry path leaves any doubt about ingress or a spherical object capable of motion it may be necessary to examine drawings or to provide special access for the object probe For first numerals 5 and 6 see test descriptions below for acceptance criteria 166 IPO No test required IP1_ The full diameter of a rigid sphere 50 mm in diameter must not pass through any opening at a test force of 50 N IP2_ The full diameter of a rigid sphere 12 5 mm in diameter must not pass through any opening at a test force of 30 N IP3 Arigid steel rod 2 5 mm in diameter must not pass through any opening at a test force of 3 N IP4_ Arigid steel wire 1 mm in diameter must not pass through any opening at a test force of 1 N IP5_ The test specimen is supported inside a specified dust chamber where talcum powder able to pass through a square meshed sieve with wire diameter 50 mm and width between wires 75 mm is kept in suspension Enclosures for equipment subject to thermal cycling effects category 1 are vacuum pumped to a reduced internal pressure relative to the surrounding atmosphere maximum depression 2 kPa maximum extraction rate 60 volumes per hour If extraction rate of 40 to 60 volumes h is obtained test is continued until 80 volumes have been drawn through or 8 h has elapsed If extraction rate is less than 40 volumes h at 20 kPa depression test time 8 h Enclosures for equipment not subject to
250. port abdrives 144 Factory Installed Options Phase I amp Il Drives Human Interface and Wireless Interface Modules IP20 NEMA Type 1 Position e Catalog Code 2 Catalog Code 3 LCD Digital Speed LCD Full Numeric i Catalog Code C Catalog Code 0 No HIM Blank Cover Catalog Code 8 Catalog Code 5 LCD Programmer Only Door Mounted LCD Full DPI WIM Numeric Frame 10 amp Up Documentation Cat Code Description Position f Quick Start Guide and CD E No Documentation N Internal Brake IGBT Cat Code Drive Input Voltage Brake IGBT Frame Position g Standard 1 3 Y 4 Y 5 Y 208 480V ac Optional 4 6 N 6 Y 9 Y Allen Bradley AC Adjustable Frequency Drives PowerFlex 700S Internal Dynamic Brake Resistors Control Options Phase II Control Catalog These resistors have a limited duty cycle Refer to the PowerFlex Logix Code Dynamic Braking Selection Guide to determine if an internal Expansion m A sp E E Control Option Cassette Board SynchLink Position k resistor will be sufficient for your application An external resistor Phasc may be required Control N A N A Standard N Expanded No No A Brake Resistance Cat Code Expanded No Yes B Drive Input Voltage Frame Q Position h heiss Expanded Yes No C do 9s X Contr
251. purchased which ensures after hours assistance For more information on Rockwell Automation s Technical Support offering for Drives please visit http www ab com support abdrives Active Inactive Product Support All current drive products receive support at no charge Allen Bradley 153 AC Adjustable Frequency Drives Technical Services and Support Discontinued Obsolete Product Support Description Cat No Single Incident Support Stand alone Drive TS SISAD Custom Drive TS SICD Annual Site Contract One Year Stand alone Drive TS OYSAD One Year Custom Drive TS OYCD ProtectionPlus Drive Start Up With ProtectionPlus Drive Start Up Services from Rockwell Automation users can leverage the extensive product and industry experience of Rockwell Automation technicians to quickly commission drives and reduce the time between integration and actual start up SupportPlus For consultation on high performance drive applications the SupportPlus program is offered SupportPlus uses expert level Rockwell Automation system engineers to support the user s engineering team SupportPlus engineers will work with the end user to layout the appropriate architecture configure drives recommend programming techniques and provide application ProtectionPlus Drive Start Up Services verify drive installation to ensure proper electrical mechanical and environmental criteria are met This includes verification of
252. r may be required Brake Resistance Cat Code Drive Input Voltage Frame Q Position h 480V ac 0 2 N Std Engineered Drives Program Only 0 62 id 1 2 5 Hp 62 Y 240V ac 1 7 5 Hp 22 Y 2 22 Y 0 115 Y 480V ac 1 115 Y 2 68 Y 240V ac 0 2 N Sta Internal EMC Filter Drive Input Common Cat Code Voltage Frame CE Filter Mode Choke Position i 480V ac 0 6 Yes Yes A Std Engineered Drives Program Only 240V ac 0 6 Yes No B Std Allen Bradley Internal Communication Adapters Cat Code Description Position j ControlNet C DeviceNet D EtherNet E HVAC H Interbus l No Adapter N PROFIBUS P Remote I O R RS 485 DF1 S Engineered Drives Program Only LonWorks L 1 O Options Cat Code Description One Required Position k Standard 24V dc ac A Standard 115V ac B Vector 24V dc C Vector 115V ac D Drive input interface only Other configured options may require option C1 or user supplied 115V Vector Control option utilizes DPI Only Feedback Options Vector Control Only Description One Required Position I No Encoder 0 Std 12V Encoder 1 Special Options Quick Ship Program Description One Required Position n No Special Option NN Std Quick Ship QS Drive Duty Description One Required Position p Normal Duty ND Heavy Duty HD 97 AC Adjusta
253. r in product literature UL Certification Generally Rockwell Automation pursues applicable UL certification for its products The following are relevant types of certifications granted by Underwriters Laboratories UL UL Recognized UR or UL Recognized to Canadian cUR or UL Recognized to US and Canadian cURus safety requirements under the Component Recognition Program of Underwriters Laboratories Inc UL Recognition may be for use in general as well as Hazardous Locations The UL Recognition mark for products recognized for use in Hazardous Locations will be accompanied by the phrase Industrial Control Equipment for use in Hazardous Locations and information which indicates the nature of the Hazardous Locations This is typically Class I Division 2 Groups A B C D UL Listed UL UL Listed to Canadian cUL or UL Listed to US and Canadian safety standards cULus UL Listing may be for use in general as well as hazardous Locations The UL Listed mark for products certified for use in Hazardous Locations will be accompanied by the phrase Industrial Control Equipment for use in Hazardous Locations and information which indicates the nature of the Hazardous Locations This is typically Class I Division 2 Groups A B C D Although Rockwell Automation is only using the Class I Division 2 Group A B C D designation on its products it should be noted that this hazardous location classification is equivalent to the internat
254. r respective series first or second Second numerals 7 and 8 do not imply suitability for exposure to water jets second characteristic numeral 5 or 6 unless dual coded e g IP 5 IP 7 The IEC standard permits use of certain supplementary letters with the characteristic numerals If such letters are used refer to IEC 529 for the explanation 165 AC Adjustable Frequency Drives Important Safety and Product Information Abridged Descriptions of IEC Enclosure Test Requirements Refer to IEC 529 for complete test specifications e g test apparatus configuration tolerances etc For Metric Conversion factors see page Important 2 Tests for Protection Against Access to Hazardous Parts first characteristic numeral The first characteristic numeral of the IP number indicates compliance with the following tests for the degree of protection against access to hazardous parts It also indicates compliance with tests as shown in the next section for the degree of protection against solid foreign objects The protection against access to hazardous parts is satisfactory if adequate clearance is kept between the specified access probe and hazardous parts For voltages less than 1000V AC and 1500V DC the access probe must not touch the hazardous live parts For voltages exceeding 1000V AC and 1500V DC the equipment must be capable of withstanding specified dielectric tests with the access probe in the most unfavorable posit
255. rFlex 700H AC Drive Drive Description The PowerFlex 700H AC drive offers a cost effective compact package for general purpose variable speed applications It is designed to meet the demands for space flexibility and performance The many features allow the user to easily configure the drive for most application needs Available ratings include 200 to 900 Hp at 480V ac 150 to 900 Hp at 600V ac and 160 to 800 kW at 690V ac An LCD Human Interface Module also used with the PowerFlex 70 700 and 7008 provides multilingual text for startup metering programming and troubleshooting PowerFlex 700H AC drives are configurable for Volts per Hertz or Sensorless Vector control modes to meet a wide variety of application needs This control is housed in a module which is separately removable from the power structure The control module is the same for all drive ratings simplifying installation and maintenance for the entire product line Optional I O is available as 24V de or 115V ac Optional internal communication modules are available as user installed kits These provide fast and efficient control and or data exchange with host controllers over popular interfaces These interfaces include DeviceNet ControlNet EtherNetTM TP PROFIBUS DP Interbus Remote I O Serial Communications and other open control and communication networks PC tools such as DriveExplorer and DriveTools SP assist with programming monitoring and tr
256. radley AC Adjustable Frequency Drives PowerFlex 70 Standard Drives Selection Panel Mount IP 20 NEMA Type 1 Position d A 200 240V ac Three Phase Drives IP20 NEMA Type Output Amps Nominal Power Ratings 1 without HIM 240V ac Input 208V ac Input Normal Duty Heavy Duty Cat No Cont 1 Min 3 Sec Cont 1 Min 3 Sec kw Hp kw Hp 20A Frame Size 2 2 2 4 3 3 2 5 2 7 3 7 0 37 0 5 0 25 0 33 B2P2A0AYNNNCO A 4 2 4 8 6 4 4 8 5 5 7 4 0 75 1 0 0 55 0 75 B4P2A0AYNNNCO A 6 8 9 0 12 7 8 10 3 13 8 1 5 2 0 14 1 5 B6P8AOAYNNNCO B 9 6 10 6 14 4 11 12 1 16 5 2 2 3 0 1 5 2 0 B9P6AOAYNNNCO B 15 3 17 4 23 2 17 5 19 2 26 2 4 0 5 0 3 0 3 0 B015A0AYNANCO C 22 24 2 33 25 8 27 8 37 9 5 5 7 5 4 0 5 0 B022A0AYNANCO D 28 33 44 32 2 37 9 50 6 7 5 10 5 5 7 5 B028A0AYNANCO D 42 46 2 63 43 55 5 74 11 15 2 8 10 B042A0AYNANCO D 54 63 84 62 1 72 4 96 6 15 20 11 15 B054A0AYNANCO E 70 81 108 78 2 93 1 124 18 5 25 18 20 B070A0AYNANCO E Catalog code corresponds to output amps in these columns Drive must be programmed to lower voltage to obtain higher currents shown at right 380 480V ac Three Phase Drives IP20 NEMA Type Output Amps Nominal Power Ratings 1 without HIM 480V ac Inputx 380 400V ac Input Normal Duty Heavy Duty Cat No Cont 1 Min 3 Sec Cont 1 Min 3 Sec kw Hp kw Hp 20A Frame Size
257. raph are warranted for a period of thirty 30 days from the date of shipment to Buyer or the remainder of the original warranty term whichever is longer d Services Seller warrants that Products comprised solely of services e g training on site repair engineering and custom application programming services will be performed by appropriately skilled personnel employed or retained by Seller e Open Box Products Seller warrants that hardware Products sold as Open Box e g customer and distributor returns factory refurbished or reconditioned etc will be free from defects in material and workmanship for a period of ninety 90 days from the date of invoice from Seller or its appointed distributor as the case may be Open Box Products while serviceable may not reflect the latest series or revision Repaired or replacement Products provided as a result of this warranty subparagraph are similarly warranted for a period of thirty 30 days from the date of shipment to Buyer or the remainder of the original ninety day warranty term for that particular Product whichever is longer Buyer Specifications Compatibility Seller does not warrant and will not be liable for any design materials construction criteria or goods furnished or specified by Buyer including that sourced from other manufacturers or vendors specified by Buyer Any warranty applicable to such Buyer specified items will be limited solely to the
258. rating The 2 sec output current is only available at initial start or drive operating at light load Normal duty rating is limited to 35 C surrounding air Allen Bradley 117 AC Adjustable Frequency Drives PowerFlex 700H User Installed Options Human Interface and Wireless Interface Modules No HIM Blank Plate 20 HIM AO LCD Digital Speed 20 HIM A2 LCD Full Numeric 20 HIM A3 LCD Programmer Only 20 HIM A5 DPI NEMA 1 WIM 20 WIM N1 DPI NEMA 4 WIM Remote Panel Mount Remote Panel Mount Remote Panel Mount Full Numeric Programmer Only 20 HIM C3S 20 HIM C5S 20 WIM N4S Remote Panel Handheld Local Mount IP66 UL Drive Mount Type 4x 12 Description Cat No Cat No No HIM Blank Plate 20 HIM AO LCD Display Digital Speed 20 HIM A2 LCD Display Full Numeric Keypad 20 HIM A3 20 HIM C3S LCD Display Programmer Only 20 HIM A5 20 HIM C5S DPI NEMA 1 WIM 20 WIM N1 DPI NEMA 4 WIM 20 WIM N4S For indoor use only Includes a 1202 C30 interface cable 3 meters for connection to the drive 118 Human Interface Module Accessories Description Cat No Bezel Kit for LCD HIMs NEMA 1 20 HIM B1 PowerFlex HIM Interface Cable 1 m 39 in 20 HIM H10 Cable Kit Male Female gt 0 33 Meters 1 1 Feet 1202 H03 1 Meter 3 3 Feet 1202 H10 3 Meter 9 8 Feet 1202 H30 9 Meter 29 5 Feet 1202 H90 DPI SCANport One to Two Port Split
259. rbus Communication Adapter DPI 20 COMN I PROFIBUS Communication Adapter DPI 20 COMM P ControlNet Fiber Communication Adapter DPI 20 COMM Q Remote I O Communication Adapter DPI 20 COMM R RS 485 DF1 Communication Adapter DPI 20 COMM S DriveLogix ControlNet Communication Adapter 1788 CNC DriveLogix Comm Option ControlNet Redundant Coax 1788 CNCR DriveLogix Comm Option ControlNet Fiber 1788 CNF DriveLogix Comm Option ControlNet Redundant Fiber 1788 CNFR DriveLogix Comm Option DeviceNet Open Conn 1788 DNBO DriveLogix Comm Option EtherNet IP Twisted Pair 1788 ENBT DriveLogix5730 Comm Option Embedded EtherNet IP 3 EU External DPI Communications Kit en External DPI I O Option Board ee External Comms Power Supply sn Compact I O Module 3 Channel 1769 SM1 For use with DriveLogix option only For use only with External DPI Communications Kits 20 XCOMM DC BASE 3 For use with Phase II Control ONLY Requires Logix Expansion Board 20D DL2 LEBO when used with Phase Il Control Communication Accessories Description Cat No Smart Self powered Serial Converter RS 232 1203 SSS includes 1203 SFC and 1202 C10 Cables Serial Null Modem Adapter 1203 SNM ControlNet T Tap Right Angle 1 Meter Coax Cable Assembly 1786 TPR Allen Bradley Accessories Note Please refer to publication number 1756 TD008 for details on SynchLink
260. ribed in this publication those responsible for the application and use of these products must satisfy themselves that all necessary steps have been taken to assure that each application and use meets all performance and safety requirements including any applicable laws regulations codes and standards Factory provided user manuals and technical documentation should not be solely relied on for those purposes Rockwell Automation reserves the right to change the features or characteristics of its products at any time Therefore the information contained in this publication is subject to change at any time without notice The illustrations charts diagrams and layout examples shown in this guide are intended solely as examples Since there are many variables and requirements associated with any particular installation Rockwell Automation can not assume responsibility or liability including intellectual property infringement liability for actual use based upon the examples shown in this publication Allen Bradley Publication SGI 1 1 General Information Safety Guidelines for Solid State Control available from you local Rockwell Automation office describes some important differences between solid state equipment and electromechanical devices which should be taken into consideration when applying products such as those described in this publication Allen Bradley Metric Conversion Chart Metric Conversion Factors
261. rive Packages for Fan amp Pump Applications 575V 60 Hz Three Phase Drive Ratings Input Line Reactor Output Line Reactor IPOO Open Style IP11 NEMA Type 1 IPOO Open Style 1P11 NEMA Type 1 kw Hp Amps Cat No Cat No Cat No Cat No 3 Impedance 2 2 3 0 3 9 1321 3R4 C 1321 3RA4 C 1321 3R4 C 1321 3RA4 C 4 0 5 0 6 1 1321 3R8 C 1321 3RA8 C 1321 3R8 C 1321 3RA8 C 5 5 7 5 9 0 1321 3R12 C 1321 3RA12 C 1321 3R12 C 1321 3RA12 C 7 5 10 11 1321 3R12 B 1321 3RA12 B 1321 3R12 B 1321 3RA12 B 11 15 17 1321 3R18 B 1321 3RA18 B 1321 3R18 B 1321 3RA18 B 15 20 22 1321 3R25 B 1321 3RA25 B 1321 3R25 B 1321 3RA25 B 18 5 25 27 1321 3R35 C 1321 3RA35 C 1321 3R35 C 1321 3RA35 C 22 30 32 1321 3R35 B 1321 3RA35 B 1321 3R35 B 1321 3RA35 B 30 40 4 1321 3R45 B 1321 3RA45 B 1321 3R45 B 1321 3RA45 B 37 50 52 1321 3R55 B 1321 3RA55 B 1321 3R55 B 1321 3RA55 B 45 60 62 1321 3R80 B 1321 3RA80 B 1321 3R80 B 1321 3RA80 B 55 75 77 1321 3R80 B 1321 3RA80 B 1321 3R80 B 1321 3RA80 B 75 100 99 1321 3R100 B 1321 3RA100 B 1321 3R100 B 1321 3RA100 B 90 125 125 1321 3R130 B 1321 3RA130 B 1321 3R130 B 1321 3RA130 B 110 150 144 1321 3R160 B 1321 3RA160 B 1321 3R160 B 1321 3RA160 B 5 Impedance 2 2 3 0 3 9 1321 3R4 D 1321 3RA4 D 1321 3R4 D 1321 3RA4 D 4 0 5 0 6 1 1321 3R8 D 1321 3RA8 D 1321 3R8 D 1321 3RA8 D 5 5 7 5 9 0 1321 3R12 Ct 1321 3RA12 C 1321 3R1
262. rmal Duty 600 1321 3R600 B 1321 3RA600 B 20CD650 Heavy Duty 650 1321 3R600 B 1321 3RA600 B 20CD650 Normal Duty 700 1321 3R750 C 1321 3RA750 C 20CD750 Heavy Duty 700 1321 3R750 C 1321 3RA750 C 20CD750 Normal Duty 800 1321 3R750 C 1321 3RA750 C 20CD820 Heavy Duty 700 1321 3R750 C 1321 3RA750 C 20CD820 Normal Duty 900 1321 3R850 C 1321 3RA850 C Allen Bradley AC Adjustable Frequency Drives PowerFlex 700H Factory Installed Options Human Interface and Wireless Interface Modules IP20 NEMA Type 1 Position e Catalog Code 0 No HIM Blank Cover Catalog Code C Catalog Code 3 LCD Full Numeric Catalog Code 8 Door Mounted LCD DPI WIM Full Numeric Frame 10 amp Up Internal Brake IGBT Brake IGBT Frame Position g None 9 10 11 N Optional 9 Y Internal EMC Filter and Common Mode Choke Drive Input Voltage CE Filter Common Cat Code Mode Choke Position i 380 500V ac amp with No 600 690V ac sm Filter Choke B 380 500V ac amp No 600 690Vac No Filter Choke is For use with ungrounded distribution systems Control and I O Options Cat Code Description Position k 24V dc Digital Input w Analog I O amp 115V ac Digital Output A 115V ac Digital Input w Analog I O amp 115V ac Digital Output B None N Allen Bradley 121 AC Adjustable Frequency Drives PowerFlex 700H Notes 122 Allen Bradley AC Adjustable Frequency Drives PowerFlex 700S
263. roduct Packaged Product Standards this page this page Description this page page 39 Catalog Number Explanation page 32 page 40 Product Selection page 33 page 41 User Installed Options page 34 Conformity to Standards The PowerFlex 400 conforms to the following Conformity to UL Listed Standard Product Packaged Product Y IEC Designed to Meet CUL Listed for Canada CE Approved C Tick UL508C Plenum Rating SSA A A Allen Bradley ae gt Ex Amp T L y PowerFlex 400 AC Drive Family Drive Description The PowerFlex 400 offers a wide range of features for integration into fan and pump applications Drives are available in four frame sizes that cover ratings from 2 2 to 37 5 kW 3 to 50 Hp 200 240V AC and 2 2 to 110 kW 3 to 150 Hp 380 480V AC Drives feature integral RS485 communications and support Drive Serial Interface DSI Modbus RTU and Metasys N2 Protocols PowerFlex 400 drives are also compatible with PC tools such as DriveExplorer and DriveTools SP which assist with programming monitoring and troubleshooting PowerFlex drives An integral 2 line 16 character LCD operator keypad provides text for metering programming and troubleshooting LED indicators provide system configuration status 31 AC Adjustable Frequency Drives PowerFlex 400 Catalog Number Explanation To interpret the meaning of a catalog number m
264. rrosive agents 6 9 Y Y Y Y Y See below for abridged description of NEMA enclosure test requirements Refer to NEMA Standards Publication No 250 for complete test specifications Non hazardous materials not Class III ignitable or combustible Allen Bradley 163 AC Adjustable Frequency Drives Important Safety and Product Information Abridged Description of NEMA Enclosure Test Requirements 6 2 Rod Entry Test A 1 8 in 3 18 mm diameter rod must not be able to enter enclosure except at locations where nearest live part is more than 4 in 102 mm from an opening such opening shall not permit a 1 2 in 13 mm diameter rod to enter 6 3 Drip Test Water is dripped onto enclosure for 30 minutes from an overhead pan having uniformly spaced spouts one every 20 sq in 12900 mm of pan area each spout having a drip rate of 20 drops per minute Evaluation 6 3 2 2 No water shall have entered enclosure 6 4 Rain Test Entire top and all exposed sides are sprayed with water at a pressure of 5 psi 0 35 kg cm from nozzles for one hour at a rate to cause water to rise 18 in 457 mm in a straight sided pan beneath the enclosure Evaluation 6 4 2 1 No water shall have reached live parts insulation or mechanisms Evaluation 6 4 2 2 No water shall have entered enclosure 6 5 1 1 2 Outdoor Dust Test Alternate Method Enclosure and external mechanisms are subjected to a stream of wa
265. s HIM IP20 NEMA Type 1 Position e Catalog Code 0 Catalog Code 2 No HIM Blank Cover LCD Digital Speed Catalog Code 3 LCD Full Numeric Internal Dynamic Brake Resistors These resistors have a limited duty cycle Refer to the PowerFlex Dynamic Braking Selection Guide to determine if an internal resistor will be sufficient for your application An external resistor may be required Drive Input Brake Resistance Cat Code Voltage Frame Q Position h B 62 Y 208V ac C 62 M D 22 NY B 115 Y 480V ac C 115 M D 62 y B 115 M 600V ac C 115 Y Internal EMC Filter and Common Mode Choke Catalog Code 4 Catalog Code 5 LCD Analog Speed LCD Programmer Only Drive Input Cat Code Voltage Frame CE Filter Position i Cat Code 208V ac B C D Yes A Description Position e B C D E Yes A Blank Cover 0 E 4 5 6 Yes A LCD Display Digital Speed 2 B C D E No N LCD Display Full Numeric Keypad 3 GOV ae 4 5 6 Yes A LCD Display Analog Speed 4 Potentiometer LCD Display Programmer Only 5 Internal Communication Adapters Cat Code Documentation Description Position j Gatleode ControlNet Coax C Description Position f DeviceNet D User Manual A EtherNet IP E RS 485 HVAC H Internal Brake IGBT o meer LonWorks E Driv iliput Cat Code PROFIBUS DP P Voltage Brake IGBT Frame P
266. s handheld or remote 3 Required in addition to 20 HIM H10 for distances up to a total maximum of 10 Meters 32 8 Feet Communication Option Kits Description Cat No ControlNet Communication Adapter Coax 20 COMM C DeviceNet Communication Adapter 20 COMM D EtherNet IP Communication Adapter 20 COMM E RS485 HVAC Communication Adapter 20 COMM H Interbus Communication Adapter 20 COMM I LonWorks Communication Adapter 20 COMM L PROFIBUS DP Communication Adapter 20 COMM P ControlNet Communication Adapter Fiber 20 COMM Q Remote I O Communication Adapter 20 COMM R RS 485 DF1 Communication Adapter 20 COMM S External DPI Communications Kit ag External DPI I O Option Board Se External Comms Power Supply 20 XCOMM AC PS1 Compact I O Module 3 Channel 1769 SM1 Smart Self powered Serial Converter RS 232 DF1 1203 SSS includes 1203 SFC and 1202 C10 Cables Serial Null Modem Adapter 1203 SNM Other Options Description Cat No 5V 12V Encoder 20A ENC 1 DriveGuard Safe Off Board 20A DG01 Service Connection Board SK M9 SCB1 115V ac Interface AK M9 115VAC 1 Frame E Flange Gasket AK M9 GASKET1 E4 Works only with PowerFlex 70 Enhanced Control Provides temporary DPI HIM connection for NEMA 1 and Flange drives with cover removed 53 AC Adjustable Frequency Drives PowerFlex 70 Dynamic Brake Resistors Small Duty Internal Dynamic Brake Resistors Limited duty resistors
267. s limited to 40 C surrounding air Stand Alone Wall Mount IP54 NEMA Type 12 Position d G 380 480V ac Three Phase Drives 480V ac Input 380 400V ac Input Output Amps Normal Heavy Output Amps Normal Heavy Frame Cont 1 Min 3 Sec Duty Hp Duty Hp Cont 1 Min 3 Sec Duty kW Duty kW Cat No Size 96 77 106 116 144 154 75 60 105 85 116 128 1158 170 55 45 20BDO96GOANNANCO 5 125 96 1138 144 163 168 100 75 125 96 138 144 163 168 55 45 20BD125GOANNANCO 5 156 125 172 188 233 250 125 100 170 140 187 210 255 280 90 75 20BD156GOANNANCO 6 180 156 198 234 270 312 150 125 205 170 220 255 289 313 110 90 20BD180GOANNANCO 6 180 273 270 372 360 200 150 260 205 gt 286 308 390 410 132 110 20BD248G0ANNANCO 6 Catalog number corresponds to output amps in these columns Drive must be programmed to lower voltage to obtain higher currents shown at right Frame 5 and 6 drives have dual current ratings one for normal duty applications and one for heavy duty applications in parenthesis The drive may be operated at either rating Rating is limited to 45 C surrounding air Rating is limited to 40 C surrounding air 80 Allen Bradley AC Adjustable Frequency Drives PowerFlex 700 User Installed Options Human Interface and Wireless Interface Modules LCD Digital Speed 20 HI
268. s provided as a result of this warranty subparagraph are similarly warranted for a period of six 6 months from the date of shipment to Buyer or the remainder of the original warranty term for that particular Product whichever is longer b Software and Firmware Unless otherwise provided in a Seller or third party license Seller warrants that standard software or Allen Bradley AC Adjustable Frequency Drives Important Safety and Product Information firmware Products furnished hereunder when used with Seller specified hardware will perform in accordance with published specifications prepared approved and issued by Seller for a period of one 1 year from the date of invoice from Seller or its appointed distributor as the case may be Seller makes no representation or warranty express or implied that the operation of the software or firmware Products will be uninterrupted or error free or that the functions contained therein will meet or satisfy Buyer s intended use or requirements c Non Warranty Factory Remanufacture Repair and Field Exchange Seller warrants that non warranty factory remanufactured or field exchanged hardware Products or repaired hardware Product components will be free from defects in material and workmanship for a period of one 1 year from the date of invoice from Seller or its appointed distributor as the case may be Repaired or replacement Products provided as a result of this warranty subparag
269. s selected See Accessories for available dynamic brake modules Output Contactor An internal contactor will be sourced from control voltage to isolate the load side of the Bulletin 284 ArmorStart Distributed Motor Controller When control power is applied the output contactor is closed and when control power is removed the output contact opens There is no switching element such as a relay in the system If control power is lost then the output contactor will open since its coil power is lost A sequenced stop involving the output contact cannot be performed Source Brake Contactor An internal contactor will be used to switch the electromechanical brake on off This contactor s coil will be driven by the auxiliary relay output of the ArmorStart Distributed Motor Controller A 3 meter 3 pin cable for connection to an electromechanical brake is provided as standard when option is selected Shielded Motor Cable A 3 meter shielded 4 conductor cordset is provided instead of the 3 meter unshielded 4 conductor cordset If the EMI Filter is selected a 3 meter shielded 4 conductor cordset is provided as standard Safety Monitor The Safety Monitor Option allows for independent monitoring of the output status of the device The function is implemented using a normally closed contact which complies with IEC 60947 5 1 for mechanically linked contacts Two terminal blocks are provided as the inputs which maybe used with an external safety circui
270. se One Drive Mounted Input 3 Input 3 Output 3 Output 3 Drive Options Contactor BM1 or BM2 Adjustable Range in Brake Resistor Normal Duty Heavy Duty Normal Duty Heavy Duty Only KM Amps gt BR LRN LRH LQN LQH CF ND HD Area Factor BM1 BM2 Area Factor Area Factor Area Factor Area Factor Area Factor Area Factor Area Factor 208V ac Three Phase Drives A26 2 4 4 0 1 6 2 4 A54 AO A58 A58 A58 A58 A16 A26 4 0 6 0 2 4 4 0 A54 AO A58 A58 A58 A58 A16 A26 6 0 10 6 0 10 A54 AO A58 A58 A58 A58 A16 A26 10 16 6 0 10 A54 AO A58 A58 A58 A58 A16 A26 16 24 10 16 A54 AO A58 A58 A58 A58 A16 A26 18 30 16 24 A54 AO A60 A60 A60 A60 A16 A26 30 45 18 30 A54 AO A60 A60 A60 A60 A16 240V ac Three Phase Drives A26 1 6 2 4 1 6 2 4 A54 AO A58 A58 A58 A58 A16 A26 4 0 6 0 2 4 4 0 A54 AO A58 A58 A58 A58 A16 A26 6 0 10 4 0 6 0 A54 AO A58 A58 A58 A58 A16 A26 6 0 10 6 0 10 A54 AO A58 A58 A58 A58 A16 A26 10 16 6 0 10 A54 AO A58 A58 A58 A58 A16 A26 16 24 10 16 A54 AO A60 A58 A60 A60 A16 A26 18 30 18 30 A54 AO A60 A60 A60 A60 A16 480V ac Three Phase Drives A26 1 0 1 6 0 6 1 0 A54 AO A58 A58 A58 A58 A16 A26 1 6 2 4 1 0 1 6 A54 AO A58 A58 A58 A58 A16 A26 2 4 4 0 2 4 4 0 A54 AO A58 A58 A58 A58 A16 A26 4 0 6 0 2 4 4 0 A54 AO A58 A58 A58 A58 A16 A26 6 0 10 4 0 6 0 A54 AO A58 A58 A58 A58 A16 A26 10 16 6 0 10 A54 AO A58 A58 A58 A58 A16 A26 1
271. sprayed 3 min minimum Enclosure is immersed in water in its service position for 30 min Lowest point of enclosures less than 850 mm tall 1000 mm below surface of water Highest point of enclosures more than 850 mm tall 150 mm below surface of water Test conditions are subject to agreement between manufacturer and user but shall be at least as severe as those for IP 7 Allen Bradley 167 AC Adjustable Frequency Drives Important Safety and Product Information Notes 168 Allen Bradley For more information on Allen Bradley drives please visit our website at http www ab com drives CompactLogix ControlLogix DriveExplorer DriveTools DriveTools 2000 DriveLogix FlexLogix Logix PowerFlex ArmorStart Pocket DriveExplorer DriveTools SP DeviceLogix ArmorPoint RSLogix 5000 SoftLogix5800 SCANport SynchLink FORCE Technology Zero Stacking TorqProv DriveExecutive DriveObserver DriveTools32 DriveManager32 DriveMonitor32 DrivePanel32 DriveBlockEditor32 DriveTrending32 DriveManager DriveMonitor DrivePanel DriveBlockEditor 1336 Force 1336 IMPACT SMC Dialog Plus 160 SSC SMP 3 DriveTrending DPI DSI etc are trademarks of Rockwell Automation Trademarks not belonging to Rockwell Automation are property of their respective companies www rockwellautomation com Corporate Headquarters Rockwell Automation 777 East Wisconsin Avenue Suite 1400 Milwaukee WI 53202 5302 USA Tel 1 414 212 5200
272. t Code C3 Cat Code C5 Remote Panel Mount Remote Panel Mount LCD Full Numeric LCD Programmer Only Control Interface and Feedback Options Option Area Option Area Description Code Factor Description Code Factor Drive Mounted Drive Digital Output Options No HIM Blank Plate HO A0 Control Relays LED Display Digital Keypad H1 AO Auxiliary Contacts 2 Form C 2 N O 2 N C LCD Display Digital Keypad H2 A0 Alarm M A10 LCD Display Full Numeric Keypad H3 AO At Speed JT A10 LCD Display Analog Potentiometer H4 AO Drive Fault JF A10 LCD Display Programming Only H5 AO Drive Run JR A10 Door Mount Programmable Relay Quantity 1 PR1 A10 2 Display Full Numeric Keypad NEMA Type C3 N A Programmable Relay Quantity 1 PR2 A10 Drive Output Pilot Lights LCD Display Programming Only NEMA Type 4 12 05 N A Drive Run D2AS Al Drive Fault D2B A1 At Speed D2C A1 Drive Alarm D2D A1 Control Relay Option Control Power On JC A10 Building Management Control Interface Fire Alarm and Smoke Purge Response FASP A20 Analog Isolators Analog Input Isolator 0 10V N1 A20 Analog Input Isolator 4 20 mA N2 A20 Analog Output Isolator 0 10V N3 A20 Auto Bypass Logic BAS A2 68 Maximum of two Drive Digital Output Options can be selected Note D2A JR One Digital Output D2B JF One Digital Output D2C JT One D
273. t Required in addition to 20 HIM H10 for distances up to a total maximum of 10 Meters 32 8 Feet Allen Bradley DPI NEMA 4 WIM Remote Panel Mount Remote Panel Mount Programmer Only 20 HIM C5S 20 WIM N4S Control Cassette Option Kits Control with 1 O Cat No Standard Control No 1 0 20B STD N Standard Control with 24V dc ac 20B STD AO Standard Control with 115V ac 20B STD BO Vector Control Series B with 24V dc 20B VECTB CO Vector Control Series B with 115V ac 20B VECTB DO Vector Control option utilizes DPI Only Encoder Option Kit Vector Control Only Description Cat No 12V Encoder 20B ENC 1 1 O Option Kit Standard Control Only Description Cat No 20 DA1 A0 24V dc ac 115V ac 20 DA1 BO 81 AC Adjustable Frequency Drives PowerFlex 700 Communication Option Kits Description Cat No ControlNet Communication Adapter Coax 20 COMM C DeviceNet Communication Adapter 20 COMM D EtherNet IP Communication Adapter 20 COMM E HVAC Communication Adapter 20 COMM H Interbus Communication Adapter 20 COMM I LonWorks Communication Adapter 4 20 COMM L PROFIBUS DP Communication Adapter 20 COMM P ControlNet Communication Adapter Fiber 20 COMM Q Remote I O Communication Adapter 20 COMM R RS 485 DF1 Communication Adapter 20 COMM S 20 XCOMM External Comms Power Supply AC PS1 ue 20 XCOMM External DPI Communications Kit DC BASE 20 XC
274. t The external safety circuit monitors the status of the contactor 0 10V Analog Input The Bulletin 284 Distributed Motor Controller with Sensorless Vector Control provides a 0 10V analog input The 0 10V Analog Input 15 A factory installed option provides a 0 10V external frequency command from the 0 10V or 10V analog input or remote potentiometer A 5 pin micro receptacle is provided for connectivity for customer connection A shielded 5 conductor cordset or patch cord is recommended Allen Bradley Bulletin 284 ArmorStart Distributed Motor Controllers Catalog Number Explanation Option Option Option a b C d e f g h i j k a el g Bulletin Number Output Current Short Circuit Protection Motor Circuit 284 Combination Starter 200 240V Protector Code Description 10 10 A Rated Device b B2P3 2 3 A 0 4 kW 0 5 Hp 25 25 A Rated Device E B4P5 4 5 A 0 75 kW 1 0 Hp h ae B7P6 7 6 A 1 5 KW 2 0H D DeviceNet m Line Motor Connections Conduit Round A ArmorPoint e2 CR blank 3 meter unshielded single ended cordset male 90 Output Current CR N 3 meter shielded single ended Cc 380 480V cordset male 90 Enclosure Type Code Description CR Wx No cable F Type 4 IP67 D1P4 1 4 A 0 4 kW 0 5 Hp 7 D2P3 2 3 A 0 75 kW 1 0 Hp d D4PO 4 0 A 1 5 kW 2 0 Hp Option 1 D6PO 6 0 A 2 2 kW 3 0 Hp Code Description Torque Performance Mode i 2 D7P6
275. t Current kW Hp A Frame Size Rating Cat No Cat No 2 2 3 0 6 0 Cc IP20 UL Open Type 22C D6PON103 22C D6POF103 4 0 5 0 10 5 C IP20 UL Open Type 22C D010N103 22C D010F103 5 5 7 5 12 C IP20 UL Open Type 22C D012N103 22C D012F103 75 10 17 C IP20 UL Open Type 22C D017N103 22C D017F103 13 15 22 C IP20 UL Open Type 22C D022N103 22C D022F103 15 20 30 C IP20 UL Open Type 22C D030N103 22C D030F103 18 5 25 38 D IP30 NEMA 1 UL Type 1 22C D038A103 22 30 45 5 D IP30 NEMA 1 UL Type 1 22C D045A103 30 40 60 D IP30 NEMA 1 UL Type 1 22C D060A103 37 50 72 E IP30 NEMA 1 UL Type 1 22C D072A103 45 60 88 E IP30 NEMA 1 UL Type 1 22C D088A103 55 75 105 E IP30 NEMA 1 UL Type 1 22C D105A103 75 100 142 E IP30 NEMA 1 UL Type 1 22C D142A103 90 125 170 F IP30 NEMA 1 UL Type 1 22C D170A103 110 150 208 F IP30 NEMA 1 UL Type 1 22C D208A103 Drive terminals are sized according to UL Depending on operating ambient and wire used some local or national codes may require a larger wire size than what the power terminals can accept Multiple conductors 90 C wire and or lugs may be required Refer to the PowerFlex 400 User Manual for details on terminal block wire ranges IP30 NEMA 1 UL Type 1 can be achieved for panel mount drives with top cover and optional conduit box kit installed Field installed conversion kit specified under User Installed Options 11 and 15 kW 15 and 20 Hp Frame C flange mount drives require extern
276. t of a consolidation merger or any other form of corporate reorganization 159 AC Adjustable Frequency Drives Important Safety and Product Information Language The parties acknowledge that they have required that the agreement evidenced hereby be drawn up in English Les parties reconnaissent avoir exig la r daction en anglais du Contrat In the event of a conflict between the English and other language versions the English version will prevail Preventive Maintenance and Repair Maintenance of Solid State Control This section is excerpted from Rockwell Automation publication SGI 1 1 Safety Guidelines for the Application Installation and Maintenance of Solid State Control and parts of Section 5 of NEMA Standards Publication No ICS 1 1 1987 titled Safety Guidelines for the Application Installation and Maintenance of Solid State Control The text from the NEMA Standard has been reprinted verbatim with NEMA s permission Text set off from the NEMA standard content under the heading Information contains Rockwell Automation comments for the NEMA content immediately preceding it The comments provide information to help readers better understand the characteristics of industrial equipment employing solid state technology NEMA text is provided solely as a convenience to the reader and Rockwell Automation assumes no responsibility for its completeness or validity NEMA Standards Publication No ICS 1 1 1984 Rev No 1
277. talog Reference Ratings 480V Control Performance Features Ambient Temperature Limit for Enclosure Types Communications Options 1 eee n eer n Packaged Drive 23B 0 5 15 HP Volts per Hertz PowerFlex 70 Enhanced Control Standard Packaged Drive 21A 0 5 50 HP Vector Control VC w FORCE Technology Sensorless Vector Sensorless VC Slip Compensation Slip Compensation All Standard Drive Features Power Disconnect Options Control and Interface Options 1 0 Options Quick Disconnect Options Program Specific Documentation Additional Custom Capabilities IP 66 NEMA 4 12 0 to 40 C NEMA 4 indoor outdoor IP 66 NEMA 4X 0 to 40 C indoor outdoor Integral RS485 Optional DeviceNet EtherNet IP PROFIBUS DP Bluetooth Encoder Speed Control Encoderless Speed Control Torque Regulation Volts per Hertz All Standard Drive Features Power Disconnect Options Control and Interface Options Bypass and Bypass Options Power Conditioning Options Motor Interface Options Order Specific Documentation Additional Custom Capabilities IP 20 NEMA 1 0 to 40 C PowerFlex 700 Vector Control Standard Packaged Drive 21B 0 5 200 HP Vector Control VC w FORCE Technology Sensorless VC Slip Compensation Encoder Speed Control Encoderless Speed Control Torque Regulation Volts per Hertz Adjustable Voltage Control All Standard Drive Features Power Disconnect Options Control and
278. ter Cable 1203 S03 Required only when HIM is used as handheld or remote Required in addition to 20 HIM H10 for distances up to a total maximum of 10 Meters 32 8 Feet Protective Cover for DC Bus or Internal Brake IGBT Terminals Description Touch Cover Converts IPOO0 Open Type drive to IP20 NEMA Type 1 No wiring space 20 OPT TC provided Top Hat Converts IP00 Open Type drive to a IP20 NEMA Type 1 Allows for wiring space GC Communication Option Kits Description Cat No ControlNet Communication Adapter Coax 20 COMM C DeviceNet Communication Adapter 20 COMM D EtherNet IP Communication Adapter 20 COMM E HVAC Communication Adapter 20 COMM H Interbus Communication Adapter 20 COMM I LonWorks Communication Adapter 20 COMM L PROFIBUS DP Communication Adapter 20 COMM P ControlNet Communication Adapter Fiber 20 COMM Q Remote I O Communication Adapter 20 COMM R RS 485 DF1 Communication Adapter 20 COMM S 20 XCOMM External Comms Power Supply AC PS1 ims a 20 XCOMM External DPI Communications Kit DC BASE 20 XCOMM External DPI I O Option Board IO OPT1 Serial Null Modem Adapter 1203 SNM Smart Self powered Serial Converter RS 232 includes 1203 SSS 1203 SFC and 1202 C10 Cables Compact I O Module 3 Channel 1769 SM1 For use only with External DP Communications Kits 20 XCOMM DC BASE Allen Bradley AC Adjustable Frequency Drives PowerFlex 700H
279. ter at 45 gallons 170 5 liters per minute from a 1 in 25 4 mm diameter nozzle directed at all joints from all angles from a distance of 10 to 12 feet 3 to 3 7 meters Test time is 48 seconds times the test length height width depth of enclosure in feet or a minimum of 5 minutes No water shall enter enclosure 6 5 1 2 2 Indoor Dust Test Alternate Method Atomized water at a pressure of 30 psi 2 11 kg cm is sprayed on all seams joints and external operating mechanisms from a distance of 12 to 15 in 305 to 381mm at a rate of 3 gallons 11 liters per hour No less than 5 ozs 142 gms of water per linear foot of test length height length depth of enclosure is applied No water shall enter enclosure 6 6 External Icing Test Water is sprayed on enclosure for one hour in a cold room 35 6 F 2 C then room temperature is lowered to approximately 23 F 5 C and water spray is Enclosure Selection Criteria Continued controlled so as to cause ice to build up at a rate of 1 4 in 6 4 mm per hour until 3 4 in 19 mm thick ice has formed on top surface of a 1 in 25 4 mm diameter metal test bar then temperature is maintained at 23 F 5 C for 3 hours Evaluation 6 6 2 2 Equipment shall be undamaged after ice has melted external mechanisms not required to be operable while ice laden 6 7 Hosedown Test Enclosure and external mechanisms are subjected to a stream of water
280. tes the status of the communication link FAULT LED Indicates Controller Fault trip condition The Reset Button as a local trip reset Inputs The inputs are single keyed 2 inputs per connector which are sourced from DeviceNet power 24V DC with LED status indication Outputs The outputs are dual key connectors Which are sourced from the control voltage power which can be either 24V DC 120V AC or 240V AC with LED status indication Motor Cable With every Bulletin 284 ArmorStart Distributed Motor Controller a 3 meter unshielded 4 conductor cordset is provided with each unit as standard If the optional EMI filter is selected a 3 meter shielded 4 conductor cordset is provided with each unit as standard Fault Diagnostics Fault diagnostics capabilities built into the Bulletin 284 ArmorStart Distributed Motor Controller help you pinpoint a problem for easy troubleshooting and quick re starting Short Circuit Overload Phase Short Ground Fault Stall Control Power Loss nput Short Circuit Overcurrent Overtemperature DeviceNet Power Loss nternal Communication Fault DC Bus Fault EEPROM Fault Hardware Fault Restart Retries Miscellaneous Fault Network and Expandable I O Capabilities The Bulletin 284D ArmorStart Distributed Motor Controller delivers enhanced control to access parameter settings and provides fault diagnostics and remote start stop control Devi
281. thermal cycling effects and designated category 2 in the relevant product standard are tested for 8 h without vacuum pumping Protection is satisfactory if talcum powder has not accumulated in a quantity or location such that as with any other kind of dust it could interfere with the correct operation of the equipment or impair safety and no dust has been deposited where it could lead to tracking along creepage distances IP6_ All enclosures are tested as category 1 as specified above for IP5 The protection is satisfactory if no deposit of dust is observable inside the enclosure at the end of the test Tests for Protection Against Water second characteristic numeral The second characteristic numeral of the IP number indicates compliance with the following tests for the degree of protection against water For numerals 1 through 7 the protection is satisfactory if any water that has entered does not interfere with satisfactory operation does not reach live parts not designed to operate when wet and does not accumulate near a cable entry or enter the cable For second numeral 8 the protection is satisfactory if no water has entered the enclosure IP 0 No test required IP 1 Water is dripped onto the enclosure from a drip box having spouts spaced on a 20 mm square pattern at a rainfall rate of 1 mm min The enclosure is placed in its normal operating position under the drip box Test time 10 min Allen Br
282. thesis The drive may be operated at either rating Rating is limited to 40 C surrounding air CE Certification testing has not been performed on 600V class drives 3 Rating is limited to 35 C surrounding air Release pending at date of printing Verify before ordering 128 Allen Bradley AC Adjustable Frequency Drives PowerFlex 700S DC Input Drives DC input for Frames 1 4 use the same code as AC input Refer to the tables below for frames 5 and 6 325V dc Input Drives 325V dc Input 280V dc Input IP20 NEMA Type 1 Output Amps Normal Heavy Output Amps Normal Heavy Cat No Frame Cort 1 Min 3 Sec Duty Hp Duty Hp Cort 1 Min 3 Sec Duty kW Duty kW 20D Size 104 80 115 120 175 160 40 30 120 92 132 138 175 175 30 22 Y N104A0ENNANANE 5 130 104 143 156 175 175 50 40 130 104 143 156 175 175 37 30 Y N130A0ENNANANE 5 154 130 169 195 231 260 60 50 177 150 195 225 266 300 45 37 Y N154A0ENNANANE 6 192 154 211 231 288 308 75 60 221 177 243 266 308 308 55 45 Y N192A0ENNANANE 6 260 205 286 305 390 410 100 75 260 205 286 305 390 410 66 55 Y N260A0ENNANANE 6 Catalog number corresponds to output amps in these columns Drive must be programmed to lower voltage to obtain higher currents shown at right Frame 5 and 6 drives have dual current ratings o
283. tion Bulletin Number 23B 1 3 Voltage Rating D 5 Drive Rating 6PO 6 8 Enclosure D 9 Interface Module 1 10 Emission Class 0 11 Version 4 12 Special Options NN 13 14 Base List Fused Disconnect Switch P6 Hand Off Auto S1 23B D6P0D104NN P6 S1 Allen Bradley 21 AC Adjustable Frequency Drives PowerFlex 40 Packaged Drives Programs Catalog Number Explanation To interpret the meaning of a catalog number match the values of the catalog number code in positions a b c etc with the tables labeled a b c etc below Position 1 3 4 5 6 8 9 10 11 12 13 14 15 16 a b C d e f g h i j a e j Drive Options Code Type Code Interface Module Code Description PowerFlex 40 Fixed Keypad on Drive E22 DeviceNet Quick Disconnect Bottom DeviceNet Quick Disconnect b f Er Left Side Voltage Rating Emission Class J10x ZAC Master Left Feed Code Ph Code Rating J11 ZAC Master Right Feed D 480V ac 3 0 Nat Filtered J12x ZAC Infeed Left Feed J13 ZAC Infeed Right Feed c g J14 Intermediate Left Feed Amp Rating Version J15x Intermediate Right Feed 480V 60Hz Input Code Version P3 Motor Circuit Protector Code Amps kW Hp 4 RS485 Standard TO Disconnect Switch Fused 1P4 14 0 4 0 5 D DeviceNet a iiid p E a eturn and Power Disconnec 2P3 2 3 0 75 1 0 E EtherNet IP Aux Contact am 4 0 1 5 2 0 r PROFIBUS DP R4 D
284. tion 529 describes standard Degrees of Protection that enclosures of a product are designed to provide when properly installed Allen Bradley Summary The publication defines degrees of protection with respect to e Persons Equipment within the enclosure Ingress of water It does not define e Protection against risk of explosion Environmental protection e g against humidity corrosive atmospheres or fluids fungus or the ingress of vermin Note The IEC test requirements for Degrees of Protection against liquid ingress refer only to water Those products in this catalog which have a high degree of protection against ingress of liquid in most cases include Nitrile seals These have good resistance to a wide range of oils coolants and cutting fluids However some of the available lubricants hydraulic fluids and solvents can cause severe deterioration of Nitrile and other polymers Some of the products listed are available with seals of Viton or other materials for improved resistance to such liquids For specific advice on this subject refer to your local Allen Bradley Sales Office IEC Enclosure Classification The degree of protection is indicated by two letters IP and two numerals International Standard IEC 529 contains descriptions and associated test requirements that define the degree of protection each numeral specifies The following table indicates the general degree of protection refer to Abridged
285. tomer must select one of the following P1 P2 P3 P4 P6 or P7 If option P1 is selected power disconnecting means and drive branch circuit protection must be supplied by user Description Option Code No Input Protection P1 Drive Input Fuses P2 Drive Circuit Breaker P3 Drive Bypass Mode Circuit Breaker P4 Drive Disconnect Switch Fused P6 Drive Bypass Mode Fused Disconnect P7 This option can not be used with Bypass This option must be used in conjunction with a Bypass Option Power and Bypass Options Description Option Code Contactor Drive Input P11 t3 Contactor Drive Output P12 183 No Bypass Required BO Manual Bypass B1 4364 Automatic Bypass B2 4 Either an input contactor or output contactor may be chosen but not both when Bypass is selected 5 This option must be used in conjunction with the Auxiliary Fault Contact option J2 Includes a Class 10 Adjustable Thermal Overload Relay that does not require separate heater elements This option includes Drive Off Bypass selector switch and must be used in conjunction with the Auxiliary Fault Contact option J2 Also requires option B1 3 Requires option C1 or user supplied 115V option C5 BO or B1 must be selected Control Power and Line Reactor Options Description Option Code 115V Control Power Drive Options Only C1 115V Control Power User Supplied
286. top of frame ratings frame A D These packages are a subset of the Standard Packaged Drives Program noted below and can be ordered through the Passport order entry system This program uses the Standard Control version of the PowerFlex 70 Standard Packaged Drives The Standard Packaged Drives Program allows users to create drive packages based on their specific needs A complete drive package may be specified by assembling a single catalog number string that includes a base drive and all required options Packaging is available for 208V 240V 480V and 600V requirements in NEMA Type 1 IP20 NEMA 4 12 IP65 indoor and NEMA 3 4 IP65 outdoor The program consists of a fully defined catalog string identified within this price sheet Focused on higher volume repeat business the standard designs provide consistent manufacturing and minimizes customer resources by reducing engineering manufacturing and installation time Typical delivery is 10 business days from order entry and can be ordered through the Passport order entry system This program uses the Standard Control version of the PowerFlex 70 Engineered Drives The Engineered Drives Program offers users the ability to create drive packages beyond the Standard Packaged Drives offering This program supports both the Standard and the Enhanced Control versions of the PowerFlex 70 Options may or may not be defined within this publication Product can be ordered by Assembling a catalog string
287. ty 0 33 1321 3R2 D 1321 3RA2 D 1321 3R2 D 1321 3RA2 D 20BB2P2 Normal Duty 0 5 1321 3R2 D 1321 3RA2 D 1321 3R2 D 1321 3RA2 D 20BB4P2 Heavy Duty 0 75 1321 3R4 A 1321 3RA4 A 1321 3R4 A 1321 3RA4 A 20BB4P2 Normal Duty 1 1321 3R4 A 1321 3RA4 A 1321 3R4 A 1321 3RA4 A 20BB6P8 Heavy Duty 15 1321 3R8 B 1321 3RA8 B 1321 3R8 A 1321 3RA8 A 20BB6P8 Normal Duty 2 1321 3R8 A 1321 3RA8 A 1321 3R8 A 1321 3RA8 A 20BB9P6 Heavy Duty 2 1321 3R8 A 1321 3RA8 A 1321 3R12 A 1321 3RA12 A 20BB9P6 Normal Duty 3 1321 3R12 A 1321 3RA12 A 1321 3R12 A 1321 3RA12 A 20BB015 Heavy Duty 3 1321 3R12 A 1321 3RA12 A 1321 3R18 A 1321 3RA18 A 20BB015 Normal Duty 5 1321 3R18 A 1321 3RA18 A 1321 3R18 A 1321 3RA18 A 20BB022 Heavy Duty 5 1321 3R18 A 1321 3RA18 A 1321 3R25 A 1321 3RA25 A 20BB022 Normal Duty 7 5 1321 3R25 A 1321 3RA25 A 1321 3R25 A 1321 3RA25 A 20BB028 Heavy Duty 7 5 1321 3R25 A 1321 3RA25 A 1321 3R35 A 1321 3RA35 A 20BB028 Normal Duty 10 1321 3R35 A 1321 3RA35 A 1321 3R35 A 1321 3RA35 A 20BB042 Heavy Duty 10 1321 3R35 A 1321 3RA35 A 1321 3R45 A 1321 3RA45 A 20BB042 Normal Duty 15 1321 3R45 A 1321 3RA45 A 1321 3R45 A 1321 3RA45 A 20BB052 Heavy Duty 15 1321 3R45 A 1321 3RA45 A 1321 3R55 A 1321 3RA55 A 20BB052 Normal Duty 20 1321 3R55 A 1321 3RA55 A 1321 3R55 A 1321 3RA55 A 20BB070 Heavy Duty 20 1321 3R55 A 1321 3RA55 A 1321 3R80 A 1321 3RA80 A 20BB070 Normal Duty 25 1321 3R80 A 1321 3RA80 A 1321 3R80 A 1321 3RA80 A 20BB080 Heavy Duty 25 1321 3R80 A 1321 3RA80 A 1321 3R80 A 1321 3RA80 A
288. ve Mounted LCD Full Numeric amp A Door Mounted Bezel w Blank Cover NEMA Type 1 Drive Mounted LCD Full Numeric amp B Door Mounted Bezel w LCD Digital Speed NEMA Type 1 Door Mounted Bezel w LCD Full Numeric NEMA Type 1 Drive Mounted LCD Full Numeric amp D Door Mounted Bezel w LCD Analog Speed NEMA Type 1 Drive Mounted LCD Full Numeric amp E Door Mounted Bezel w LCD Programmer Only NEMA Type 1 Drive Mounted LCD Full Numeric amp E Door Mounted Bezel w LCD Full Numeric NEMA Type 12 Drive Mounted LCD Full Numeric amp G Door Mounted Programmer Only NEMA Type 12 f Documentation User Manual Standard g Brake Code w Brake IGBT Y Yes Std for 0 3 N No Std for 4 6 Brake IGBT is standard on Frames 0 3 and optional on Frame 4 6 drives h Brake Resistor Code w Resistor Y x4 Yes Internal N No Standard Not available for Frame 3 drives or larger Engineered Drives Program Only Allen Bradley AC Adjustable Frequency Drives PowerFlex 700 Packaged Drives Programs I o Feedback Options Emission Code Type Code Description 0 None ND Normal Duty Filter w CM Choke 1 12V Encoder HD 8 Heavy Duty ld B0 8 Bypass Not Required B Filter wo CM Choke B1 Manual Byp
289. vided Products with no rights to sublicense disclose disassemble decompile reverse engineer or otherwise modify the software or firmware Packing and Marking Buyer specified packing or marking may be subject to additional charges not otherwise included in the price of the Products Weights and Dimensions Published or advertised weights and dimensions are estimates or approximations only and are not warranted Prices Prices and other information shown in any Seller publication including product catalogs and brochures are subject to change without notice and to confirmation by specific quotation Such publications are not offers to sell and are maintained only as a source of general information Prices do not include sales use excise customs value added or similar taxes Buyer will pay or reimburse Seller for all such taxes as may be applicable Time and material services will be provided in accordance with Seller s published service rates including applicable overtime and travel expenses in effect as of the date such services are provided unless otherwise confirmed by Seller s written quotation or order acknowledgment Billable service time includes travel time to and from the job site and all time Seller s representatives are available for work and waiting whether on or off the job site to perform the services Changes and Substitutions Buyer requested order changes including those affecting the identity scop
290. werFlex 40 Contents Standard Product Packaged Product Conformity to Standards this page page 24 Description this page page 21 Catalog Number Explanation page 14 page 22 Product Selection page 15 page 23 User Installed Options page 17 Em Factory Installed ER Options page 23 Conformity to Standards PowerFlex 40 drives conform to the following Conformity to UL Listed Standard Product IEC Designed to Meet CE Approved C Tick AIAJ SJS Allen Bradley PowerFlex 40 AC Drive Drive Description PowerFlex 40 drives are designed to worldwide standards and ratings allowing out of the box performance around the globe Drives are available in two frame sizes that cover ratings from 0 4 to 11 kW 0 5 to 15 Hp 100 to 120 volts 200 to 240 volts 380 to 480 volts and 460 to 600 volts Drives feature integral RS485 communications and are compatible with PC tools such as DriveExplorer and DriveTools SP which assist with programming monitoring and troubleshooting PowerFlex drives 13 AC Adjustable Frequency Drives PowerFlex 40 Catalog Number Explanation Position 1 3 4 5 6 8 9 10 11 12 13 14 2B A 2P3 N 1 4 AA a b c d e g h a c4 e Drive Rating HIM Code Type 380 480V Three Phase Input Code Interface Module 22B PowerFlex
291. x D DeviceNet E EtherNet IP H RS 485 HVAC I Interbus L LonWorks P PROFIBUS DP Q ControlNet Fiber R Remote I O S RS 485 DF1 N None k Control amp I O Code 1 0 Volts Ax Standard 24V dc ac CE Enhanced 24V do PowerFlex 700 options only PowerFlex 70 options only I Feedback Code Feedback 0 None m Package Code Description A Main Input Disconnect 3 Contactor Full B Feature Bypass with Disconnect 3 Contactor Basic C Bypass with Disconnect n Reserved O Options Code Description LR Input Line Reactor Only available with Package Code A and B drives 1 0 10 HP 208V 1 0 25 Hp 9 480V and 3 0 25 HP Q 600V 105 AC Adjustable Frequency Drives PowerFlex Drive Packages for Fan amp Pump Applications Available Packaging Selections Position m 3 Contactor Full Feature 3 Contactor Basic 3 Contactor Basic Main Input Disconnect Bypass with Disconnect Bypass with Disconnect Bypass with Disconnect Catalog Code A Catalog Code B Catalog Code C Catalog Code C SS ee AAA E O O Y O al O d PowerFlex PowerFlex Drive Drive 1 200 HP e 5 Luiz ga a bh o AAR N Lo AC 1 60 HP Motor 1 150 HP 106 PowerFlex Drive 75 100 HP Allen Bradley Product Selection 208V ac Main Input Disconnect Package Code A Drive Ratings Output Current AC Adjustable Frequency Drives Pow
292. y 150 1321 3R200 C 1321 3RA200 C 1321 3R200 C 1321 3RA200 C 20DD248 Normal Duty 200 1321 3RB250 C 1321 3RAB250 C 1321 3RB250 C 1321 3RAB250 C 20DD261 Heavy Duty 200 1321 3R200 C 1321 3RA200 C 1321 3R200 C 1321 3RA200 C 20DD261 Normal Duty 200 1321 3RB250 C 1321 3RAB250 C 1321 3RB250 C 1321 3RAB250 C 20DD300 Heavy Duty 150 1321 3RB250 C 1321 3RAB250 C 1321 3RB250 C 1321 3RAB250 C Input line reactors were sized based on the NEC fundamental motor amps Output line reactors were sized based on the VFD rated output currents 4 impedance 140 Allen Bradley AC Adjustable Frequency Drives PowerFlex 700S Input and Output Line Reactors 600V 60 Hz Three Phase 3 Impedance Input Line Reactor Output Line Reactor IPOO Open Style IP11 NEMA Type 1 IPOO Open Style IP11 NEMA Type 1 Drive Cat No Duty Hp Cat No Cat No Cat No Cat No 20DE1P7 Heavy Duty 0 5 1321 3R1 C 1321 3RA1 C 1321 3R2 B 1321 3RA2 B 20DE1P7 Normal Duty 1 1321 3R2 B 1321 3RA2 B 1321 3R2 B 1321 3RA2 B 20DE2P7 Heavy Duty 1 1321 3R2 B 1321 3RA2 B 1321 3R4 D 1321 3RA4 D 20DE2P7 Normal Duty 2 1321 3R4 D 1321 3RA4 D 1321 3R4 D 1321 3RA4 D 20DE3P9 Heavy Duty 2 1321 3R4 D 1321 3RA4 D 1321 3R4 C 1321 3RA4 C 20DE3P9 Normal Duty 3 1321 3R4 C 1321 3RA4 C 1321 3R4 C 1321 3RA4 C 20DE6P1 Heavy Duty 3 1321 3R4 C
293. ying many lifting applications Available ratings include 0 5 to 100 Hp at 240V ac 0 5 to 200 Hp at 480V ac 1 to 150 Hp at 600V ac and 45 to 132 kW at 690V ac PowerFlex 700 AC drives are configurable for Volts per Hertz Sensorless Vector and Vector Control with Force Technology to meet all application needs This control is housed in a separately removable cassette which is the same for all drive ratings simplifying installation and maintenance for the entire product line I O is available as 24V de or 120V ac and an encoder interface option is also available 75 AC Adjustable Frequency Drives PowerFlex 700 Catalog Number Explanation Position 1 3 4 57 8 9 10 11 12 13 14 15 16 17 18 19 20 a b C d e f g h 1 j k l m n a c2 c4 Drive ND Rating ND Rating Code Type 400V 50 Hz Input 600V 60 Hz Input 20B PowerFlex 700 Code Amps kW Code Amps Hp 1P3 1 3 0 37 1P7 17 1 0 2P1 24 0 75 2P7 27 2 0 b 3P5 3 5 1 5 3P9 3 9 3 0 5P0 5 0 22 6P1 6 1 5 0 Voltage Rating 8P7 87 40 9PO 9 0 75 Code Voltage Ph Prechg 011 115 5 5 011 11 10 B 240V ac 3 015 154 75 017 17 15 c 400V ac 3 2 022 22 11 022 22 20 2 480V ac 3 030 30 15 027 27 25 E 600V ac 3 037 37 18 5 032 32 30 F 690V ac 3 3 2 043 43 22 041 4 40 H 540V dc 38 E N 056 56 3

Download Pdf Manuals

image

Related Search

Related Contents

Transpondeur Mode S Becker BXP 6401  Avaya Mobile Voice Client 2050 User Guide  Samsung HW-H500 دليل المستخدم  Kensington Triple Trek  Manuale Utente Per Minitorce A Gas Valex Cod. 1850123  PNY GeForce7 7300LE PCI-E 128MB GeForce 7300  JWWA B 103準拠 水道用地下式消火栓 取扱説明書(H  Oxford Infared Heater User Manual  Plustek OpticSlim M12  NOTICE D`INSTALLATION ET D`EMPLOI  

Copyright © All rights reserved.