1. html offers the complete line of Healthometer Medical Scales Visit www balances com for your next Healthometer Scale SERVICE ADDENDUM 594KL How To Change The Calibration Weight 1 Turn the scale on 2 At the same time press the TARE ZERO and KG LB buttons The letter t and a number representing the current automatic shut off value will appear on the display 3 Press the TARE ZERO button CAL and then 600 0 will appear on the display The rightmost digit will be flashing NOTE To change the desired calibration weight value use the HOLD RELEASE button to move the flashing digit to the left and use the KG LB button to increment the flashing digit 4 Press the TARE ZERO button again The display will show CAL 00 5 Press the TARE ZERO button again The display will show CAL SP Load the calibration weight default weight is 600 lbs Press TARE ZERO The display will show 600 0 or whatever the calibration weight value was set to 6 Remove the weight from the scale The scale returns to the normal weighing mode 6 http scaleman com health o meter html offers the complete line of Healthometer Medical Scales
2. to 125 F Humidity 85 rH Scale Dimensions 33 x 24 x 37 1 2 Arm Width 20 1 2 2 http scaleman com health o meter html offers the complete line of Healthometer Medical Scales Visit www balances com for your next Healthometer Scale SET UP Your scale is a precision instrument and should be handled accordingly The Health o Meter Professional Digital Chair Scale is shipped completely assembled so no additional assembly required Some protective plastic cardboard and foam will need to be removed before using Remove metal bands attached to small skid Remove cardboard at the front and the back end of the chair Remove protective foam and plastic cover on the display Plug the scale s AC adapter into the chair scale display and into the power source OPERATING INSTRUCTIONS Make sure the scale is on a hard level surface before using Press the ON OFF button to turn on the scale The indicator will start the initialization count from 000000 to 999999 Wait until 0 0 and the arrows above ZERO and STABLE appear on the display The model 594KL model is designed to provide convenient and accurate weighing to the less mobile The side arms and footrest are movable for easy access and patient comfort See Figure Place the patient on the scale The scale will display the patient weight NOTE the weigh will change until the patient is stable Once the patient is stable an arrow will appear above STABLE on th
3. Visit www balances com for your next Healthometer Scale Health o meter SA Ge ee ee es ee oe O ASSEMBLY amp OPERATING INSTRUCTIONS DIRECTIVES DE MONTAGE ET D UTILISATION INSTRUCCIONES DE MONTAJE Y USO ELECTRONIC CHAIR SCALE MODEL 594KL FAUTEUIL DE PES E LECTRONIQUE MOD LE 594KL BALANZA ELECTRONICA CON SILLA MODELO 594KL Please register your product at www homscales com Veuillez enregistrer votre produit sur www homscales com Registre su balanza en nuestro sitio Web www homscales com Rev 20110623 http scaleman com health o meter html offers the complete line of Healthometer Medical Scales Visit www balances com for your next Healthometer Scale Health o meter oa a er ee a E ey a T MODEL 594KL Thank you for your purchase of this product Please read this manual carefully and keep it handy for ready reference ENG a 2 FRANGAIS iresisnnicninscsndenincancaascnninsnidunendadudteiniennieainanbi 6 ESPANOL assests Steeceusodatantsusieanadanradoeudinansdanamaewacaieny 10 TABLE OF CONTENTS CAUTION AND WARNING seeen 2 SCALE SPECIFICATIONS ceecee 2 SET UP iyore ai ao aiaia 3 OPERATION INSTRUCTIONS eee 3 PROGRAMMING AUTO OFF IME s 3 NATIT AIC Bs seociccecates decieewn ceases tate centteeacecieee 3 TROBE SHOOTING viiertsalors ss cocci 4 CALIBRATION PROCEDURE onnee 4 LIMITED WARRANTY 0 0 eee eeeeeeeeeeeeeesneeeaeeeeeeeenneees 5 SERVICE ADDENDUM sssccccscrstea
4. cscertcsceudticenccerecdeenties 6 CAUTION AND WARNINGI To prevent injury and damage to your scale please follow these instructions very carefully Do not transport the scale while the platform is loaded For accurate weighing the scale must be placed on a flat stable surface For accurate weighing verify proper operation according to the procedure described in this manual before each use Do not use in the presence of flammable materials Operating at other voltages and frequencies than specified could damage the equipment Do not leave patient unattended in the chair Do not use chair scale in place of a wheelchair to transport patients Do not bounce scale down stairs as doing so may damage internal parts SCALE SPECIFICATIONS GENERAL Health o meter s Digital Chair Scale model 594KL uses sophisticated microprocessor technology This precision instrument is designed to provide accurate reliable and repeatable weight measurements and features that make the weighing process simple fast and convenient The scale is set up to determine the weight of a stationary patient The weight can be displayed in pounds or in kilograms The unit can be operated using its AC adaptor or by a 9V DC rechargeable battery SCALE SPECIFICATIONS Power Requirements Adapter 100 249VAC 9VDC 50 60Hz Battery 6VDC Rechargeable both included Environmental Operating temperatures 5 C to 40 C 41 F to 104 F Storage temperature 1 C to 52 C 30 F
5. e display 7 Press and hold the KG LB button for 3 seconds to select the weigh mode either kilograms or pounds 8 Weight may remain displayed on the scale by pressing the HOLD RELEASE button To release press the HOLD RELEASE button again NOTE The scale will always default to the settings and units last used NO DESCRIPTION FUNCTION Health o meter 1 HOLD RELEASE Holds the value of the weighed object on the LEE MODEL 594KL display until the button is pressed again to HOLD RELEASE ES Es EA BACK LIGHT Turns eer ees back light on and off PON gt Ore ON D KG LB Ki and holding button for 3 seconds toggles between kilograms or pounds TARE ZERO Zeros the scale prior to weighing or sets a ON OFF Turns scale ON and OFF PROGRAMMING AUTO OFF TIME The 594KL has an Auto Off feature that will automatically turn the scale off after a period of inactivity This battery saving feature is programmable by the user The 594KL can be programmed to automatically power off from 0 disabled to 18 minutes The default shut off value set by the factory is 2 minutes 1 Press ON OFF and wait for the display to show 0 0 2 Atthe same time press both the TARE ZERO and KG LB buttons The display will show t along with a number representing the current shut off setting 3 Use the KG LB button to change the shut off setting The shut off values are set in 3 minute increments t 0 disab
6. hanical connection If problem persist replace the load cell Low saturation state Low A D The load cell is not connected properly Check cables and mechanical connection If problem persist replace the load cell eC CALIBRATION PROCEDURE This scale has been calibrated at the factory and does not require re calibration prior to use The following procedure should be performed only to correct any error in calibration For maximum accuracy calibration should be done in kilograms using certified weights If you only have certified weights in pounds convert them to kilograms i e 1 Ib 0 454 kg The recommended calibration weight is 200 kg however calibration can be performed using any weight no less than 20 kg and no more than 200 kg 1 Turn the scale on At the same time press the TARE ZERO and KG LB buttons t and the a number representing the current automatic shut off value will appear on the display Press the TAER ZERO button CAL and then 600 0 will appear on the display Press the TARE ZERO button again The display will show CAL 00 Press the TARE ZERO button again The display will show CAL SP Load 600LB of calibration weight on to the scale and press the TARE ZERO button The display will show 600 0 6 Remove the weight from the scale The scale returns to the normal weighing mode aro 4 http scaleman com health o meter html offers the complete line of Healthometer Medical Scales Visit w
7. l Scales Visit www balances com for your next Healthometer Scale TROUBLESHOOTING Refer to the following instructions to check and correct any failure before contacting service personnel SYMPTON POSSIBLE CAUSE CORRECTIVE ACTION Scale does not turn on Dead Battery Attach adapter to recharge battery Faulty electrical outlet Use a different outlet Bad Power Supply Replace adapter Questionable weight or the scale External object interfering with the scale Remove interfering object from the scale does not zero The display did not show 0 0 before 2 Ask the patient to get off the scale and begin weighing weighing process again Scale is not on a level floor Place the scale on a level floor and begin weighing process again Scale is out of calibration Check weight with know weight value The display shows OF The load on the scale exceeds the maximum Remove the excess weight and use the scale according to its capacity 440 Ibs 200 kg limits ERROR LIST ERROR NO DEFINITION CHECK REPLACE A D value is lower when CAL Scale is below minimum calibration weight Calibration weight must be more than 20kg The recommended calibration weight is 270kg 600 Ibs Or The load on the scale exceeds the capacity 440 Ib 200kg Remove excess weight and use the scale according to its limits High saturation state High A D The load cell is not connected properly Check cables and mec
8. led t 1 3 minutes t 2 6 minutes t 7 21 minutes 4 Press TARE ZERO to save the desired turn off value CAL will appear on the display 5 Press BACKLIGHT to exit Wait for 0 0 to appear and the scale is now ready for Fornal operation GENERAL The Maintenance and Troubleshooting sections provide instructions for maintenance cleaning troubleshooting and operator replaceable parts for the Physical Digital Chair Scale Maintenance operations other than those described in these sections should be performed by qualified service personnel MAINTENANCE Before first use and after periods of non use check the scale for proper operation and function If the scale does not operate correctly refer to quali fied service personnel 1 Check overall appearance of the total scale for any obvious damage abuse etc 2 Inspect condition of AC adapter cord and prongs replace if needed CLEANING Proper care and cleaning is essential to ensure a long life of accurate and effective operation Disconnect the scale from the AC power source 1 Clean all external surfaces with a clean damp cloth or tissue Mild soap and water solution may be used Dry with a clean soft cloth 2 Do not immerse the scale into cleaning or other liquid solution 3 Do not use Isopropyl Alcohol or other solutions to clean the display surface 3 http scaleman com health o meter html offers the complete line of Healthometer Medica
9. of God such as fire floods hurricanes and tornadoes This warranty gives you specifi c legal rights and you may also have other rights that vary from country to country state to state province to province or jurisdiction to jurisdiction To get warranty service make sure you keep your sales receipt or document showing proof of purchase Call 1 800 638 3722 or 1 708 377 0600 to receive a return authorization number Attach proof of purchase to your defective product along with your name address daytime telephone number and description of the problem Carefully package the product and send with shipping and insurance prepaid to Pelstar LLC Attention R A Repair Department 11800 South Austin Ave Unit B Alsip IL 60803 If your scale is not covered by warranty or has been damaged an estimate of repair costs or replacement costs will be provided to you for approval prior to servicing or replacing PELSTAR LLC 9500 West 55th Street McCook IL 60525 USA 1 800 638 3722 or 1 708 377 0600 ProPlus is a registered trademark of Pelstar LLC Health o meter is a registered trademark of Sunbeam Products Inc used under license Health o meter Professional products are manufactured designed and owned by Pelstar LLC We reserve the right to improve enhance or modify Health o meter Professional product features or specifications without notice PRODUCT LIFE 10 YEARS 100 000 CYCLES 5 http scaleman com health o meter
10. ww balances com for your next Healthometer Scale LIMITED WARRANTY What does the Warranty Cover Pelstar LLC scales are warranted from date of purchase against defects of materials or in workmanship for a period of one 1 year If product fails to function properly return the product freight prepaid and properly packed to Pelstar See To Get Warranty Service below for instructions If manufacturer determines that a defect of material or in workmanship exists customers sole remedy will be repair or replacement of scale at no charge Replacement will be made with a new or remanufactured product or component If the product is no longer available replacement may be made with a similar product of equal or greater value All parts including repaired and replaced parts are covered only for the original warranty period Who is Covered The original purchaser of the product must have proof of purchase to receive warranty service Pelstar dealers or retail stores selling Pelstar products do not have the right to alter or modify or any way change the terms and conditions of this warranty What is Excluded Your warranty does not cover normal wear of parts or damage resulting from any of the following negligent use or misuse of the product use on improper voltage or current use contrary to the operating instruction abuse including tampering damage in transit or unauthorized repair or alternations Further the warranty does not cover Acts
Download Pdf Manuals
Related Search
Related Contents
NETWORK POWER MONITOR R9 / NPM-R9 Sanapathic Manual Plantes momies ( 3 Mb) - nieuwkoop 技術研究開発及び実用化に対する支援等 SUSE Linux-Dokumentation 「ぽけっと」 2009年10月号(PDF:901.3KB) Cooler Master Sniper MANUAL DEL USUARIO Eurofase 17535-038 Installation Guide DOT MATRIX PRINTER MODEL CBM-910 Copyright © All rights reserved.