Contents
1. Always lit Arming status Blinking quickly Stay safe arming status Blinking slowly Coming into delayed arming status GSM signal Blinking every 1 second GSM signal weak or SIM card not found LED Blinking every 3 seconds GSM module and SIM card working properly Not lit Without electricity first time energization Upon correctly installed SIM card all wired sensors if applicable and antenna the DC power can be connected Upon power up the alarm panel will carry a self test sequence as below e Six Defense Zones LED and two Functional LED s on front panel will flash in order once and end with a buzzer long Beep e The GSM Signal LED flashes with one second interval for checking the GSM signal e If GSM network detected all right Beep sound stops and Signal LED becomes flashing every three seconds the GSM signal and SIM card are all confirmed normal system is READY Now switch the stand by battery switch to ON remote control coding Remote control coding When the alarm panel is disarmed follow the steps below to add remote control s to panel 1 Press the SET key once and release immediately alarm panel returns one short Beep and all Defense zone LED s light this is the configuration mode for remote control coding Press any key on the remote control to trigger a wireless signal to the Panel 3 When the panel receives signal and Beep twice it means remote control ke
2. send SMS Messages 123431 or using phone should input 1234 31 32 user number Add or delete 2 group of phone number for voice calling upon alarm triggered 33 user number Add or delete 3 group of phone number for voice calling upon alarm triggered 34 user number Add or delete 4 group of phone number for voice calling upon alarm triggered 35 user number Add or delete 5 group of phone number for voice calling upon alarm triggered 36 user number Add or delete 6 group of phone number for voice calling upon alarm triggered 37 user number Add or delete 1 group of phone number for receiving SMS messages Example if the user wants to add phone number 12345678 send SMS Messages 12343712345678 or using phone should input 1234 37 12345678 Example if the user wants to delete second group number send SMS Messages 123437 or using phone should input 1234 37 38 user number Add or delete 2 group of phone number for receiving SMS messages 39 user number Add or delete 3 group of phone number for receiving SMS messages 50 new password Modify user operation password For example if user wants to set new user password as 4321 please send SMS Messages 1234504321 or using phone should input 1234 50 4321 51 00 99 Set Delayed Arming when pr
3. BOATSTEWARD GSM Boat Monitor User manual 1 System Foreword This wireless GSM intelligent monitoring system is built on leading microprocessor technology with advanced GSM digital signal processing power It is a highly integrated system of text messages multiple mode s of wireless coding long distance appliances controlling short messages identification and other technologies When alarming it will automatically inform of the alerting device and location through text messages It is stable reliable and safe With human manipulation and telecom phone line removed it can be comprehensively applied to places at which wire phone networks can NOT cover protection needed It is able to protect users property and personnel safety 2 General introduction of functions ten zones set as normal stay safe intelligent emergency open or closed types etc Using phone cellphone or SMS to configure amp control the panel remotely Four wired zones six wireless zones each zone can be equipped with many accessories Three groups of phone numbers for SMS messages One normally open signal output which can be externally linked to operate heating etc Built in short message contents Short message content from alarming zone can be amended Wireless intelligent study coding compatible with 2 262 normal encoding and a million group encoding convenient and flexible for adding or reducing accessories Telephone long distance telecont
4. ation should be clean so that the sensor can be attached to the door and frame firmly with double faced adhesive or alternatively fixed 2 Each sensor comprises of sensor and magnet The sensor should be installed on the fixed frame and the magnet should be placed on the movable surface with a distance not exceeding 6mm Guideline for Installing PIR Motion Sensor 1 Installation height is about 2 2 meters above ground and the optimized detection angle for most motion detectors is 90 degree s The sensor should face the detected area with this consideration for best coverage 3 Within coverage of detection there should not be any objects for obstruction There should be not be two infrared detectors in the same area as they will possibly intervere with each other 5 Avoid the IR detector facing direct sunlight cooling or heating airflows or other appliances that cause the temperature changing sharply and thus cause false alarm 6 Most infra red detector need about 5 minutes to heat up before they are READY for normal operation 7 Unless specified otherwise most infra red detector are indoor use and not reliable for use outdoor 6 Cell phone long distance control programming All programming for this panel are accomplished through cell phone or fixed phone call to the host GSM card by pressing on the keys in fixed phones or cell phones or sending short messages via cell phone On working status and the GSM network detection is no
5. d quit after 20 seconds 7 Note Difference between Defense Zone Types NORMAL Defense Zone the Panel only works on the arming status When disarming there is no response STAY SAFE Defense zone can be shut off solely through the remote control keyfob to ensure no external influence will cancel the man overboard function INTELLIGENT Defense zone if the detector in the Defense zone is triggered only once it will not immediately alarm But if being triggered once again within 30 seconds after the first triggering it will alarm immediately EMERGENCY Defense zone no matter on arming or disarming status if detector is triggered it will alert Usually used in connection with Smoke Detectors Gas Detectors and emergency button etc CLOSED Defense zone no matter arming or disarming status detectors will not alert even being triggered 8 Leaving factory default Password 1234 Long distance control Open Ringing times once Siren timing 1 minute Aural remote control siren open Delayed arming Osecond Delayed alerting 0 second 9 System Specification Input voltage DC 9V 12V Standby current lt 25mA Alerting current lt 450 mA Wireless frequency 315 433 868 915MHZ 2262 1 5 4 7M EV1527 300K GSM SYSTEM supporting GSM850 900 1800 1900MHz Standby battery NIF HIAAA 6 DC7 4V Siren loudness 110dB Accessories parameters this annunciator is compatible with PT2262 code PT2240 c
6. e Zone 1 LED on this is the configuration mode of zone 1 3 Trigger the detector s for this zone to send a wireless signal to the Panel When the panel receives the signal and Beep twice it means the detector has been added to the panel successfully Repeat this step for all detectors in this zone 5 If panel receives signal and Beep only once it means this detector has been learned before If panel receives signal and Beep for 3 times it means error By pressing SET you can step to each zone and repeat step 3 for detectors in all zone s 7 Pressing SET key again and again until all Defense zone LED off to exit the configuration model and system READY again Note The panel can learn up to 32 detectors of different types Deleting sensors from the panel When the panel is disarmed follow the steps below to delete sensors from the panel 1 Press the SET key once and release immediately alarm panel returns one short Beep and all Defense zone LED s are lit this is the configuration mode for remote control coding 2 Press SET key once and release again until the LED of the Defense zone wanted is on this is the configuration mode of your target zone 3 Then press and hold the SET key for 3 seconds panel Beep for a long time and when all Defense zone LED s go out then all detectors in this zone have been deleted Guideline for Installing Magnetic sensor 1 The surface for sensor install
7. en by command positive and ground wires of siren reversed repair or change plug or jack change the jack line activate siren by command use another siren to double check reverse the wires to try 7 the transmission distance of detector to panel is too short a nearby emitter is sending code Panel receiver stoppage standby battery of the Panel insufficient move one detector next to panel and try identify the interfering source and eliminate it check Panel power whether plugged well 8 the signal LED blinking quickly SIM card un loaded SIM card is setting PIN code GSM signal weak reload SIM card cancel PIN code of SIM change to place with strong signal Suggested TEXT TEMPLATES for your phone TEXT Set alarm 12341 ALARM ON Unset Alarm 12340 ALARM OFF Relay On Heating 12343 HEATING ON Relay Off Heating 12344 HEATING OFF 12 Alarm Status Enquiry 123420 ALARM STATUS Alert amp Alerting Number 123421 ALERT ALERTING No Add Phone Nol for SMS 123437 eK 1 SMS phone No Add Phone No 2 for SMS 123438 HHH 21 SMS phone No 13
8. ess the arming key from the remote control it will not enter into arming status immediately but delay for a certain number of second _ Range From 0 to 99 seconds For example set delayed arming for 10 seconds send SMS Messages 12345110 or using phone should input 1234 51 10 52 00 99 Set Delayed Alarming on the arming status if a detector is triggered the Panel will not alarm at once It will delay a certain time before making voice calling sending SMS message or sound the siren _ Range The time can be set from 0 to 99 seconds _ For example set delayed alarming time as 10 seconds send SMS Messages 12345210 or using phone should input 1234 52 10 53 00 20 Setting the siren sounding time when the Panel triggered Default time is 1 minutes _ Range From 1 20 minutes _ Forexample if you want to set the siren alerting time 5 minutes 7 send 12345305 or using phone should input 1234 53 05 54 0 1 Open and close of alerting linkage If the Panel alerts need the relay open linkage or not 1 means linkage needed and 0 not _Forexample Panel relay output is connected to flashlight and other equipment If output alerting it needs linkage blinking Send SMS Messages 1234541 When the Panel triggered the output relay at the back of the Panel will be connected and external equipment will start up Telephone setting just press
9. ncy alerting If an emergency arises press on the emergency key in the remote control unit or the man overboard fobs this in turn will operate the sounder and send a text message 4 Installation and debugging host and SIM card installation The panel should be installed in a central zone of the monitored area so as to make sure that all wireless detectors can be best received Take care to keep away from large scale metal objects or appliances with high frequency interference The control panel B a i ie ann 2 Siren output port 4 4 ae 9 3 Linkage output port ia 4 Speaker p gt wreLess osu il 5 Wired Defense zone input Alarm System Security 6 SET Key 7 Stand by electricity switch 8 Antenna pedestal 9 SIM card slot Yal gB 10 Defense zone indication light Ba 11 Arming light 12 Signal light o 5 40 4 10 1112 E x a 5 s gt n u _ 5 3 pa 5 The host settling indicating information function Signal Interpretation Buzzer Short Beep once Key pressing indication Long Beep once Confirm receipt of a key stroke Continuous short Beep for 2 times Correct command received Continuous short Beep for 3 times Error in command Beep at moderate intervals SIM card not found Defense Zone Always lit Defense zone alerting LED Blinking Defense zone coming into delayed alerting Arming LED
10. ns Defense zones to 6 DB means the type of Defense zone 1 means NORMAL Defense Zone 2 means STAY SAFE Defense zone 3 means INTELLIGENT Defense zone 4 means EMERGENCY Defense zone 5 means CLOSED Defense zone Chas two types of status 0 means siren no sound when alarming 1 means siren sound when alarming For example to set 5 Defense zone as NORMAL Defense Zone 8 and the 5 Defense zone alarming requires siren sounding send SMS Messages 12346005 11 61 AA B C D This command is used to set the status of the four wired Defense zones d AA is double subarea use 07 to 10 to refer to Defense zones 7 to 10 B means the type of Defense zone 1 means NORMAL Defense Zone 2 means STAY Defense zone 3 means INTELLIGENT Defense zone 4 means EMERGENCY Defense zone 5 means CLOSED Defense zone Chas two types 0 and 1 0 means no rings in that Defense zone when alerting 1 means ringing in that Defense zone when alerting D has two types 0 and 1 O means open circuit alerting and 1 means short circuit alerting _ For example set Defense zone 7 as EMERGENCY Defense zone no siren ringing when the 7 Defense zone alerts and short circuit alarming send SMS Messages 12346107101 13 0000 This command to restore the factory default setting This command will only delete the password but not delete the remote control and sensors already programmed _ For example if
11. ntent Used to set SMS Messages content given by Panel when the first Defense zone alerts SMS Messages content can NOT exceed twelve characters For example send SMS Messages 123481 the front door is opened At that time when the first Defense zone is triggered the SMS Messages of the front door is opened will be sent to the short message alarming number 82 Defense zone two SMS Messages content Used to set SMS Messages content given by Panel when the second Defense zone alerts ditto 83 Defense zone two SMS Messages content Used to set SMS Messages content given by Panel when the third Defense zone alerts ditto The forth to ninth Defense zone can be inferred as above 90 Defense zone ten SMS Messages content Used to set SMS Messages content given by Panel when the tenth Defense zone alerts ditto Telephone alert receiving After host alerts it will automatically dial all pre set telephones and cell phones in sequence When the user picks up the phone it will immediately broadcast alerting record and let user obtain the alarming information After receiving the phone if you only listen to alerting voice without long distance control please directly hang up the host will continuously dial the latter phone for alerting until someone picks up If there is no person to receive the calls the host will dial all phones in circulati
12. ode and EV1527 shorten code In use of PT2262 code timing resistor is suggested 1 5M to 4 7M In use of EV1527 shorten code timing resistor is 300K The address code AO A7 of door status switch infrared and other accessories can be any code We do not suggest it is all empty Data code D3 D0 is any code except 0001 0010 or 0100 It is suggested to use 1010 11 11 Troubleshooting Problem Probable Reasons Available Solutions 1 Alarm does not dial out no arming alerting phone incorrectly set parts improperly installed code no match SIM card overdue do arming operation re set according to the specification coordinating the location of parts re coding 5 pay to the SIM card 2 cannot long distance operation password input wrongly or forgotten retry password or reset password 3 no record indication when alerting voice message not recorded record voice message 4 remote control keyfob out of order coding un matched with the Panel insufficient battery power battery pieces poor contact or voltage un matched with Panel re learn the remote control change battery to correct type contact the local dealer to change the matched remote control keyfob 5 infrared detector out of order low power change to the same type battery 6 siren without sound siren plug or jack in short circuit or broken line siren out of order closed sir
13. on for three times then automatically hang up and at the same time it conducts long distance remote control on the alerting host through telephone and cellphone keyboard operation 1 key Arming 3 key Monitoring 5 key Talkback open 7 key Siren ringing 9 key Relay open 2 key Disarming 4 key Monitoring closed 6 key Talkback closed 8 key Siren closed 0 key Relay Closed key Quits from the status and hang up the system will not dial the next group of numbers NOTE monitoring time is 20 seconds If you wish to continue to monitor user needs to press 3 key again To support talkback function the host needs to connect to another passive loudspeaker which is 8 ohm and its power above 0 5W Telephone long distance operation Dial the phone number connected to the alerting panel through telephone or cell phone After a cycle of ringing input password default password is 1234 then pressing phone or cell phone keys 10 Complete operation is as follows 1 key Arming 2 key Disarming 3 key Monitoring 4 key Monitoring closed 5 key Talkback open 6 key Talkback closed 7 key Siren ringing 8 key Siren closed 9 key Relay open 0 key Relay Closed key Quits from the status and hang up the system will not dial the next group of numbers key Enter the system settling If without any operations the host will automatically hang up an
14. rmal Use cell phone or fixed phone to dial SIM card number in the panel it will automatically receive the call After pick up by the panel enter the password the default password is 1234 then press key to enter phone long distance function settling General Command Syntax There are two methods of configuring the alarm panel they are sending SMS command to panel via mobile phone and interactive setup using any analog phone set 1 General command pattern sent via SMS is password command parameter e g setting SMS phone no 1234379999999 2 general input sequence sent via phone interactively is call in key in password key in key in command key in parameter key in using the above same example no need to key in one by one after receipt of the confirmation beep 1234 37999999 Number setting and function setting command as follow 12 0 1 Disable and enable SMS Messages function 0 means not activated e 1 means activated Default activated Example to disable SMS Messages function send SMS Messages 1234120 or using phone should input 1234 12 0 31 phone number Add or delete 1 group of phone number for voice calling upon alarm triggered Example if the user wants to add phone number 12345678 send SMS Messages 12343112345678 or using phone should input 1234 31 12345678 Example if the user wants to delete 1 group number
15. rol for arming disarming and controlling appliances EEPROM information protection information will never be lost Built in NI Lithium battery will automatically be transferred to stand by after outage with short message prompting DC supply and standby twenty four hour normal guarding and unbroken service Panel using double triple or quadruple GSM GPRS wireless industry module depending on model which is stable and reliable 3 Manipulation specification 3 1 Arming Arming means that all detectors are working When something triggers the detectors the alerting system will alarm at once After arming operation the Set light on the panel will remain on Remote control operation pressing on the arming key in the remote control unit once will Set 3 2 Stay safe arming Stay is for arming the Man Overboard Board fobs and or gas detector smoke detector and bilge alarm When armed the Set light on the panel will flicker Remote control operation pressing on the arming key then the stay key in the remote control unit once each will Set 3 3 Disarming operation Disarming means that when the panel alerts it can stop the alerting or put the system into disarm status After disarming even triggering detectors can NOT make the panel alert except for the detectors in emergency Defense zone s Bilge level Smoke Detector Gas Detector or the emergency key in the remote control unit After disarming arming light goes out 3 4 Emerge
16. those key on the phone 55 0 1 Used to set whether the siren sounds when the panel is set or unset via remote control Value 1 means sound and 0 not Default is making sound For example send SMS Messages 1234551 meaning siren without indicating voice when arming and disarming by remote control keyfob Telephone setting just press those key on the phone 56 AAAA Used to set system time _ For example to set system time as half past 20 o clock send SMS Messages 1234 562030 This means to set system time as half past 20 o clock Telephone setting is just press those key on the phone 57 AAAA BBBB Used to set first group of timing arming and disarming For example send SMS Messages 12345722000700 to Panel This means from 22 o clock at night it automatically enters into arming status and automatically disarms at 7 o clock in the morning Telephone setting is just press those key on the phone 58 AAAA BBBB Used to set second group of timing arming and disarming For example send SMS Messages 12345812001300 to Panel This means from 12 o clock at noon it automatically enters into arming status and automatically disarms at 13 o clock in the afternoon telephone setting just press those key on the phone 60 AA B C This command is used to set six Defense zones status AA is double subarea and 01 to 06 mea
17. yfob has been added to the panel successfully this remote control can now be used to control the panel If the panel receives a signal and Beep only once it means remote control keyfob has been learned before 4 All remote controls required can be configured by repeating step 3 above 5 Pressing SET key again and again until all Defense zone LED off to exit the configuration model and system READY again Note The Panel allows a maximum of 20 remote control keyfob s Remote control deletion When the panel is disarmed follow the steps below to delete remote control to panel 1 press the SET key once and release immediately alarm panel returns one short Beep and all Defense zone LED s light this is the configuration mode for remote control coding 2 Then press and hold the SET key for 3 seconds panel Beep for a long time and when all Defense zone LED s go out then all remote control s have been deleted Note For the remote control keyfob deletion operation one operation will delete all remote control keyfob s Defense zone coding Defense zone coding When the alarm panel is disarmed follow the steps below to add sensors or detectors to panel 1 Press the SET key once and release immediately alarm panel returns one short Beep and all Defense zone LED s light this is the configuration mode for remote control coding 2 Press SET key once and release immediately Defens
18. you need to restore the factory default setting send 1234130000 to the main unit _ If the users forget the password thento restore the device you need to use Forced Restore Steps are E Turn off the back up battery switch and AC power E Press and hold RESET button at the back while turn on the power E Keep press and hold the RESET button for about 5 seconds until the buzzer gives one long Beep and all LED flash in sequence then release RESET button all setting deleted phone number deleted password return to 1234 all remote control and sensors deleted alarm panel fully returned to factory setting Operation Commands Following commands only for SMS Messages long distance operation and settlement O Long distance SMS Messages disarming send SMS Messages 12340 1 Long distance SMS Messages arming send SMS Messages 12341 2 Long distance SMS Messages STAY arming send SMS Messages 12342 9 Long distance SMS Messages Relay closing send SMS Messages 12343 AH Long distance SMS Messages Relay opening send SMS Messages 12344 20 To inquire arming and disarming status send SMS Messages 123420 21 To inquire alerting number and alert receiving number configured in the panel send SMS Messages 123421 80 Used to inquire SMS Messages contents from all Defense zones For example send SMS Messages 123480 81 Defense zone one SMS Messages co
Download Pdf Manuals
Related Search
Related Contents
Answers to Exercises SF-1000 fog machine user manual NEC VersaPro J カタログ MSDS Desgarregar e imprimir o manual completo () Quantum 7100 User's Manual ubuntu for non-geeks ubuntu for non-geeks GRASA ALIMENTARIA W-A 278 1 Press - B&H Photo Video Digital Cameras, Photography Basespace User Manual Copyright © All rights reserved.