GFK2194F IC69xDNM200 IPI - GE Intelligent Platforms: Support

image

Contents

1. 1 00 1 04 Aug 2004 IC693DNM200 Firmware Boot Firmware EDS File Version Catalog Suffix Version Version 9030master eds Date Comments Label change No changes to features CD 1 25 1 00 1 04 Jul 2011 ak performance or compatibility Firmware Version 1 25 corrects issue with BD 1 25 1 00 1 04 Jul 2006 faults caused by multiple successive COMMREQs BC 1 22 1 00 1 04 Nov 2004 AB 1 18 1 00 1 04 Dec 2003 AA 1 16 1 00 1 04 Aug 2002 Upgrades Firmware version 1 25 of the DeviceNet module firmware replaces all previous versions It is backward compatible with all previous firmware versions of the DeviceNet modules C693DNM200 and IC693DNS201 The module can be field upgraded to firmware version 1 25 using the following upgrade kit which can be downloaded from the Support website http support ge ip com Upgrade kit 444752253 G03 DeviceNet Master IC694DNM200 BB IC693DNM200 CD 3 September 2014 GFK 2194F Known Restrictions and Open Issues in this Release Restriction Rack Locations Supported Description The DeviceNet Master modules DNM200 are supported in the following rack types For the RX3i main rack only any slot except slot 0 For the Series 90 30 main rack only any slot except slots 0 and 1 The DeviceNet Master modules are NOT supported in remote or expansion racks Input Scan Rate Whenever the PLC is in RUN mode the DNM200 module requires the CPU to sc
2. NM200 s configuration should always include at least one slave module RX3i Logs Fault when Upgrading DNM Firmware Configuration Download with no Network Power The RX3i CPU will log an Unsupported Hardware fault against the DNM200 when upgrading the DNM200 s firmware This fault can be safely ignored The DeviceNet Master module DNM200 fails during the second store of HWC when there is no network power Users should make every effort to ensure that DeviceNet network power is available to the DNM200 when storing Hardware Configuration power cycling the PLC with configuration available in retentive memory reading Hardware Configuration from Flash EEPROM If the module fails because of this issue restore network power and power cycle the rack that contains the DNM200 Module Restart Complete The Module Restart Complete fault is not supported for either DNM200 or DNS201 as indicated in the user s manual GFK 2196 This will be corrected in the next revision of the manual Configuration as POLL and COS CYC The DeviceNet specification does not allow a single device to be configured as both Polled on one connection and COS or Cyclic on the other connection If configured this way one of the connections will only consume data and will not produce data back to the master device Server Status EX bit The EX bit in the module s Server Status field will be 1 even when Explicit Messaging is disabl
3. PACSystems RxX3i Series 90 30 DeviceNet Master IC694DNM200 BB IC693DNM200 CD GFK 2194F September 2014 IMPORTANT PRODUCT INFORMATION The DeviceNet Master Module allows a control system CPU to send and receive data over a DeviceNet network The module can act as master for up to 63 slaves on the DeviceNet NETPOWER network It can also be configured to simultaneously function as a slave to another master on ihe bus MODSTATUS NETSTATUS Features The DeviceNet Master Module allows a PACSystems RX3i or a Series 90 30 PLC to send and 1C694DNM200 receive I O data from a DeviceNet network Module features include DEVICENET Support for all standard data rates 125K 250K 500K ac ae Support for 255 bytes input data transfer and 255 bytes output data transfer per SERVICE RS232 slave Support for 3972 bytes of input data transfer and 3972 bytes of output data transfer per master Support for two I O connections per Slave Typically one connection is used for Polled and the other is used for Strobe Cyclic or COS Support for Poll Strobe Cyclic and COS I O Connections and Explicit Messaging Support for Unconnected Message Manager UCMM with one proxy connection per slave device Support for configuration of the global scan rate Support for configuration of update rates for Poll and COS Cyclic on a connection basis Support for PLC application initiated explicit messaging via a COMMREQ Master can be con
4. an its inputs at least once per second If more than 1 second expires between one input scan and the next the module declares a PLC fault defaults its outputs according to its Fault State Transmission setting and does not recover until the rack containing the module is power cycled Because of this if you have a DNM200 module in your PLC do not execute a SUS_IO function block or SVC_REQ 45 Skip Next I O Scan RxX3i users should use caution when configuring the DNM200 for a scan set that is not scanned every sweep the of sweeps times the sweep time cannot exceed 1000ms Finally RX3i users should not let the CPU s sweep time approach a length of 1000ms DNM Rejects SET_PLC_DATA GET_PLC_DATA for greater than 255 bytes The DeviceNet server function rejects any SET_PLC_DATA service request that contains more than 255 bytes and any GET_PLC_DATA service request that asks for more than 255 bytes If more than 255 bytes are attempted then SET_PLC_DATA will return error 15h FFh too much data and GET_PLC_DATA will return error 11h FFh reply data too large The descriptions of these requests in Chapter 7 of Series 90 30 Programmable Controller DeviceNet Modules GFK 2196 will be updated in the next revision of the manual DNM Network Status Only Reported when Slave Configured The DeviceNet Master module DNM200 does not present valid network status firmware ID inputs unless at least one slave is configured The D
5. ccount Configuration The HE693DNT250 module must be configured via its serial port prior to adding it to the rack configuration of the PLC No such initial module configuration is required for the DNM200 All configuration is done using the programmer Slave Status Reporting The HE693DNT250 reports slave status called Online Status in four words of AI memory The DNM200 DeviceNet Master reports slave status in 64 contiguous bits of any reference memory as configured default location is l Additional Status Information The DNM200 DeviceNet Master has three additional words of optional status information server status CAN status and firmware revision See the Series 90 30 DeviceNet Modules User s Manual GFK 2196 for more information Explicit Messaging When sending an explicit message with the HE693DNT250 module the message must be created in a block of R memory then the block s starting location and length must be moved into 4 words of AQ memory and finally the Send Explicit Message bit in the Output Data Assembly must be set Errors are reported in bits in the Input Data Assembly When sending an explicit message with an DNM200 DeviceNet Master Module the message is built in a block of memory then a COMMREQ is issued to send the message Errors are reported in the COMMREQ status word and in Word 5 of the response Block Move Function The DNM200 has no equivalent to the Block Move configuratio
6. dicates a trademark of General Electric Company and or its subsidiaries All other trademarks are the property of their respective owners Copyright 2002 2014 by General Electric Company All Rights Reserved 2 GFK 2194F Specifications DNM200 DeviceNet Master IC694DNM200 BB IC693DNM200 CD September 2014 Catalog Numbers Description IC693DNM200 IC694DNM200 Master Module for DeviceNet networks Mounting Location Series 90 30 Series 90 30 main rack Any slot except slots 0 and 1 DeviceNet Master modules cannot be installed in remote or expansion racks Environment Storage temperature 40 C to 85 C Operating temperature 0 C to 60 C Backplane Current Consumption Data rates 450mA at 5VDC typical Supports all standard DeviceNet data rates 125K 250K and 500K Baud For product standards and general specifications PACSystems RX3i refer to the PACSystems RX3i System Manual GFK 2314 Series 90 30 refer to Product Agency Approvals Standards General Specifications GFK 0867 Release Information Release History Catalog Suffix Version IC694DNM200 Firmware Boot Firmware EDS File Version Version 9030master eds Date Comments Label change No changes to features BB 1 25 1 00 1 04 Jul 2011 E performance or compatibility Firmware Version 1 25 corrects issue with AB 1 25 1 00 1 04 Jul 2006 faults caused by multiple successive COMMREQs AA 1 22
7. ed in the module s hardware configuration 4 DeviceNet Master IC694DNM200 BB IC693DNM200 CD GFK 2194F September 2014 Operating Notes Limits on the Size of the Total Configuration The number and type of slave devices and the amount of data they can exchange with the master may be limited by the CPU memory available The amount of CPU memory available for the DeviceNet configuration depends on the CPU model being used the version of the CPU firmware the number and type of other modules in the configuration the number and type of slave devices configured and the amount and type of communication in progress with an external programmer or HMI devices With Logic Developer PLC the size of the current configuration can be read by selecting Data View for the hardware configuration and adding the sizes of the components listed LD PLC will not allow configurations for the 90 30 CPU to be larger than 65 535 bytes The size of the DeviceNet configuration is also limited by the size of the user configuration space for the models listed below CPU 311 313 4 736 bytes available CPU 331 4 673 bytes available For the RX3i the size of the configuration is limited only by the total amount of user memory available Migrating from the HE693DNT250 Module If the 1C693 IC694DNM200 DeviceNet Master Module will be used to replace a HE693DNT250 master module in an existing application the following differences must be taken into a
8. figured to operate as a slave simultaneously with master operation Configurable fault behavior on loss of communication Reports loss or reestablishment of communication with slaves in PLC fault table configurable Support for 64 network device status bits Note the bit for the master itself is always zero DEVICENET Firmware update via service port on module Compatibility Compatible with PACSystems RX3i IC695CPU310 CPU Requires PACSystems release 3 5 or later CPU firmware Compatible with any Series 90 30 CPU except IC693CPU321 and IC693CPU340 Configuration size is limited for CPU311 313 331 as described under Operating Notes Requires Series 90 30 release 8 0 or later CPU firmware Release 10 or later is recommended if available for the particular CPU in use Support in Series 90 30 requires Proficy Machine Edition Logic Developer PLC version 3 0 SP1 Special 2 or later Support in RX3i requires Machine Edition Logic Developer PLC version 5 5 or later Not compatible with the VersaPro Control or Logicmaster programming software applications The Series 90 30 Hand Held Programmer IC693PRG300 cannot be used to configure this module The DNM200 supercedes the HE693DNT250 master module for new applications It may be retrofitted into existing applications of the HE693DNT250 master module but its functional differences must be taken into account For details see Operating Notes on page 4 In
9. n an enclosure certified in accordance with EN60079 15 for use in Zone 2 Group IIC and rated IP54 The enclosure shall only be able to be opened with the use of a tool
10. n parameter used for backward compatibility between newer and older versions of the HE693DNT250 Fault Reporting Fault reporting in the DNM200 can be disabled to match the behavior of the HE693DNT250 Serial Port Functionality The RS 485 port on the HE693DNT250 is used to supply configuration information to the module prior to PLC rack configuration The RS 232 port on the DNM200 DeviceNet Master Module is used for firmware upgrades DeviceNet Master IC694DNM200 BB IC693DNM200 CD 5 September 2014 GFK 2194F Hardware Installation Pre installation Check Upon receiving your 90 30 and RX3i equipment carefully inspect all shipping containers for damage If any part of the system is damaged notify the carrier immediately The damaged shipping container should be saved as evidence for inspection by the carrier As the consignee it is your responsibility to register a claim with the carrier for damage incurred during shipment GE Intelligent Platforms will fully cooperate with you however should such action be necessary After unpacking the 90 30 and RX3i equipment record all serial numbers Serial numbers are required if you should need to contact Customer Care during the warranty period All shipping containers and all packing material should be saved should it be necessary to transport or ship any part of the system Verify that all components of the system have been received and that they agree with your order If the system recei
11. ved does not agree with your order contact Customer Care Installation Location This product is intended to be for use with the 90 30 and RX3i systems Its components are considered open equipment having live electrical parts that may be accessible to users and must be installed in a protective enclosure or incorporated into an assembly that is manufactured to provide safety As a minimum the enclosure or assembly shall provide a degree of protection against solid objects up to 12mm e g fingers This equates to a NEMA UL Type 1 enclosure or an IP20 rating IEC60529 providing at least a pollution degree 2 environment Installation in Hazardous Locations The following information is for products bearing the UL marking for Hazardous Areas or ATEX marking for explosive atmospheres Class 1 Division 2 Groups ABCD e This equipment shall be installed in an ultimate enclosure suitable for the environment that is only accessible with the use of a tool e Suitable for use in Class Division 2 Groups A B C and D Hazardous Locations or nonhazardous locations only A Warning EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS DIVISION 2 A Warning WHEN IN HAZARDOUS LOCATIONS TURN OFF POWER BEFORE REPLACING OR WIRING MODULES AND A Warning DO NOT CONNECT OR DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS ATEX Zone 2 This product must be mounted i