1.     WARNING THIS COMMUNICATION PORT IS FOR FUTURE OPTIONS        2 7 Connecting the load    Before you connect your appliance s  to the inverter output  always check it s maximum power  consumption  Do not connect appliances to the inverter needing more than the nominal power  rating of the inverter continuously  Some appliances like motors or pumps  may draw high inrush  currents during startup  In this kind of situations  it is possible that the startup current exceedes   the overcurrent trip level of the inverter  In this case the output voltage will quickly decrease to limit  the output current of the inverter  If this overcurrent trip level is continuously exceeded  the inverter  will shut down and restart within 18 seconds  In this case it is advisable to disconnect this  appliance from the inverter  since it requires to much power to be driven by this inverter  Note that  at higher ambient temperature levels  the overload capacity of the inverter is reduced     Besides indicating the type of error  the red LED on the inverter also functions as an overload  indicator  When heavy loads are switched on  this LED will quickly be activated due to the inrush  current of the load  If the ERROR OVERLOAD LED stays on for 6 seconds  the inverter will shut  down and jumps into the overload error mode  see chapter 3 1     NEVER CONNECT THE INVERTER   S OUTPUT TO THE AC DISTRIBUTION  GRID  LIKE YOUR HOUSEHOLD AC WALL OUTLET  IT WILL DAMAGE THE  INVERTER     CAUTION    WHEN CONNECTI
2.   Inverter is not working  AC Present LED OFF     Possible cause   Remedy     A Eo   Power switch in OFF  0  position Push the power switch either in the ON  I  or in  the ASB  Il  position    Poor contact between the inverter s battery Clean battery terminals or inverter wire   wires and the battery terminals  contacts  Tighten battery terminal screws    Blown inverter fuse Replace damaged fuse with the correct type   Make sure you disconnect the battery before  changing the fuse  See chapter 5 2 for further  information regarding fuse replacement     Very poor battery condition Replace battery or charge it first    Remote ON OFF switch link removed and or Make sure that there is a closed circuit between    remote switch in OFF position the two Remote ON OFF switch contacts to  start the inverter     PROBLEM     Battery voltage too low or too high    error keeps on appearing    AAA en ee a A  Possible cause   Remedy    A AE A  Poor connection or inadequate wiring between   When extending the battery wires of the inverter  battery and inverter  resulting in too much make sure you use the correct wire gauge     voltage drop 1 5 times larger than the fixed battery wires   It   s  not advisable to extend the battery wires to  more than 3 meters     General failure in your electrical system  in case   Check your electrical system or consult an  of no direct battery connection  electrical engineer to check it for you    PROBLEM     Overloaded or shorted output    error keeps on ap
3.  This acoustic message will start at a battery  voltage close to the shutdown voltage    The inverter also shuts down when too high input ripple voltage is detected  reducing the inverter s  lifetime  High input ripple voltage values are mostly caused by using too small batteries and or  extending the DC cables too much or with insufficient wire gauge  When the inverter shuts down  due to too high input ripple voltage  indicated by four blinks per second  it must be restarted  manually     THE PHOENIX 12 1000 MUST BE CONNECTED ONLY TO A 12V BATTERY  SYSTEM     The inverter will not operate from a 6V battery and will be damaged when  connected to battery voltages higher than 16V        CAUTION    2 4 1 Using power supplies instead of batteries    It is not recommended to power the inverter directly from a DC power supply when full inverter  performance is required  Most power supplies are not able to supply the huge surge currents  required by the inverter  and usually generate a too high ripple voltage causing the inverter s high  ripple protection to trip     2 5 Connection to the battery    The Phoenix 12 1000 is equipped with two 25 mm  wires with a length of 1 5 meters  Unless it is  absolutely necessary  Victron Energy advises not to extend the battery wires  Extending the battery  wires may increase system losses and can cause inverter malfunctioning like tripping the input  ripple protection circuit  If it is unavoidable to extend these wires  use a wire gauge of at le
4.  and lighting        2 5 1 General precautions about working with batteries    1     Working in vicinity of a lead acid battery is dangerous  Batteries can generate explosive  gases during operation  Never smoke or allow a spark or flame in vicinity of a battery   Provide sufficient ventilation around the battery       Wear eye and clothing protection  Avoid touching eyes while working near batteries     Wash your hands when done       If battery acid contacts skin or clothing  wash immediately with soap and water  If acid    enters eye  immediately flood eye with running cold water for at least 15 minutes and get  medical attention immediately       Be careful when using metal tools in vicinity of batteries  Dropping a metal tool onto a    battery might cause a shorted battery and an explosion       Remove personal metal items such as rings  bracelets  necklaces  and watches when    working with a battery  A battery can produce a short circuit current high enough to weld  a ring or the like to metal  causing severe burns     victron energy  AO     2 6 The serial communication port    The Phoenix 12 1000 inverter is equipped with an RS485 serial communications port for future use   The communication port wiring is designed to work with a standard RJ45 terminated Ethernet  compatible patch cable  Maximum recommended cable length is approx  50 meters     DO NOT CONNECT THE INVERTER   S SERIAL COMMUNICATION PORT TO    AN ETHERNET NETWORK OR TO ANY OTHER NON COMPATIBLE  NETWORKS 
5.  from direct sunlight or heat  producing equipment  additional cooling by an external fan   Note   Don   t turn off the inverter when it   s operating in an    Inverter temperature too high  Cooling  down    error  The inverter needs this error time to cool down        PROBLEM     Too high input ripple voltage    error keeps on appearing  Possible cause   Remedy      Input voltage ripple is too large caused by poor   Reduce load  enlarge battery capacity  make   inverter installation sure the DC wires are not extended too long   lt 3  meters  and that sufficient wire gauge is used    gt 1 5x the standard equipped wire gauge    check eventual generators dynamos high ripple  chargers which are connected to the same DC  system     PROBLEM   Inverter jumps between continuous mode and pulsed ASB mode all the time    Possible cause   Remedy     Connected load is not compensated or the ratio   Connect an additional load to the output   between inrush current and continuous current   is too large        If none of the above remedies will help solve the problem you encounter  it   s best to contact your  local Victron Energy distributor for further help and or possible repair of your inverter  Do not try to  repair the inverter yourself  there are dangerous high voltages present inside  Attempts to repair  and or modify the inverter will directly void your warranty       WARRANTY    Victron Energy warrants this inverter to be free from defects in workmanship or materials for 24  month
6. A    max  50 meters    The main on off switch on the inverter frontpanel always overrides the remote on off switch  So in  order to use the remote switch  the main on off switch must be in the ON or Automatic standby   ASB  position  Maximum recommended length of the remote switch wires are 50 meters  Use  professional quality wiring for these connections to avoid easy wire damage  The recommended  wire gauge is 0 2mm   AWG24  or greater     MAKE SURE THAT WHEN INSTALLING THE REMOTE SWITCH  THE  BATTERY IS NOT CONNECTED YET     CAUTION       victron energy  Oy    2 3 The ground terminal    In order to complete the grounding circuit of your AC system  the inverter s housing can be  connected to ground by using the dedicated ground screw  See the figure below for the location of  the ground screw  Use a wire gauge of at least 2 5mm   AWG13  for the ground wire                  O   4  1    chassis ground  screw       2 4 Battery requirements    For correct operation  the battery voltage should be between 11V and 14 4V  The recommended  battery capacity is  gt  300 Ah  This capacity can be halved for short time inverter usage not requiring  more than nominal output power  The DC input current at nominal output power is approx  88A     The inverter shuts down when the battery voltage is below approx  10 5V and above approx  16V   When the battery voltage is too low or too high  first the inverter will generate one beep per second  to inform you about a possible inverter shut down 
7. AS  FALLEN TO AN ACCEPTABLE LEVEL AGAIN     WARNING  IN A TOO HIGH INPUT RIPPLE VOLTAGE    ERROR  THE INVERTER WILL  NOT AUTOMATICALLY RESTART BUT NEEDS TO BE RESET MANUALLY   Manual reset is neccesary to notify the user that something is wrong with the  inverter s installation  too small battery  too long or thin DC wires etc         3 2 Acoustic messages    To warn you before the inverter might shut down  it is equipped with an acoustic alarm  This can  be very useful when you are  for example  working with a computer that runs from the inverter   The inverter will warn you just before it is going to shut down  so you can save or finish your work  before you lose power    There are three kinds of acoustic messages depending on the cause of possible inverter  shutdown  These messages are related to the red LED blinking sequences mentioned previously     Message 1  One beep per second  The battery voltage has reached a too low or too high  level  If the battery voltage respectively decreases or increases any further  the  inverter shuts down    Message 2  Two beeps per second  The inverter will shut down soon due to an  overloaded output  Note that with heavy overloads the alarm will not sound due to  rapid inverter shut down  Normally the inverter warns approx  10 seconds before  shutdown    Message 3  Three beeps per second  The inverter will shut down when it   s temperature rises  another two degrees Celsius     victron energy  Oy    3 3 Troubleshooting guide    PROBLEM  
8. MC   Generic Immunity Standard    Signed   R  Vader    U    Authority   Managing Director    Date   27 November 2002    victron energy  MO     36    Stock number     Dealer     Victron Energy B V   The Netherlands    General phone   Customer support desk     General and Service fax     Sales fax     E mail   Internet site     Doc  no   Date     31    0 36   535 97 00   31    0 36   535 97 77   31    0 36   531 16 66   31    0 36   535 97 40    sales victronenergy com  http   www  victronenergy com    ISM010037000 REV00 doc  27 11 2002    victron energy  y    
9. NG MORE THAN ONE APPLIANCE TO THE INVERTER   IN COMBINATION WITH A COMPUTER  NOTE THAT IF ONE OF THE  APPLIANCES STARTS UP  IT CAN CAUSE YOUR COMPUTER TO REBOOT  DUE TO A SUDDEN VOLTAGE DROP     WARNING       victron energy  Oy    2 8 Turning on the inverter    When all the above requirements are checked and satisfied and all connections are made  it s  time to turn on your Phoenix inverter by pushing the power switch in the    I    position  After a short  two tone beep  the sinewave shaped output voltage gently rises until 230V 50Hz   1   or  115V 60Hz   1   is reached  ready to power your appliances     When the inverter is not supplying power to an appliance for an extended time  it is recommended  to use the inverter in Automatic Standby  ASB  mode to reduce the inverter   s own power draw  In  this case the power switch must be pushed in the   II     position  In ASB mode the inverter will  generate a testpulse on it s output once per second  to check that there is a load applied  When the  ASB mode is activated  by generating a reversed two tone beep   the blue AC Present LED will  flash continuously for 4 seconds while the inverter outputs a continuous 230V  or 115V  sinewave   After this 4 seconds the continuous output will change to a pulsed output  Every time this pulse is  generated the blue LED is activated too  in order to indicate that there   s a lethal AC voltage present  at the output  When a load is connected to the inverter output  or switched on  drawing 
10. ast 1 5  times larger than the ones supplied with the inverter  Maximum recommended battery wire length is  approx  3 meters  Make sure that the joint between the original wires and the extension wires is  made solid and with very low electrical resistance in mind     victron energy  AO     BATTERY TERMINALS   Recommended battery fuse size is   150A  200A    TO AVOID FIRE HAZARDS CAUSED BY DAMAGED DC WIRES  ALWAYS  PLACE A BATTERY SYSTEM FUSE AS CLOSE AS POSSIBLE TO YOUR    CAUTION    BATTERY     THE RED WIRE MUST BE CONNECTED TO THE POSITIVE     TERMINAL  AND THE BLACK WIRE TO THE NEGATIVE     TERMINAL OF THE    Reverse polarity connection of the battery wires can damage the inverter   Damage caused by reversed polarity is not covered by the warranty  Make sure    CAUTION the powerswitch is in the OFF    0    position before connecting the battery     IF THE INVERTER IS CONNECTED TO THE BATTERY WITH INCORRECT  POLARITY  THE DC FUSE WILL BLOW   To replace the internal DC fuse  see chapter 5 2 for further information  If the    fuse blows again  even with the correct polarity applied  the inverter is damaged  and must be returned for service     WARNING    DO NOT CONNECT OTHER DC POWERED EQUIPMENT TO THE SAME  BATTERY THAT POWERS YOUR INVERTER   It s possible that the performance of some equipment  that isn t properly    WARNING protected against ripple current  may be affected when connected to the same  battery that powers the inverter   This dosn t apply for batterychargers
11. ated externally on the product  Whenever it is likely that the earth protection has been damaged   the product must be turned off and secured against unintended operation  please contact qualified  service staff     Ensure that the in leads are fitted with fuses and circuit breakers  Never replace a safety component  with a different type  Consult the manual to determine the correct component     Before applying power  ensure that the available power source matches the configuration settings of  the product as described in the manual     Ensure that the equipment is used under the correct ambient conditions  Never operate the product in  a wet or dusty environment  Ensure there is adequate free space for ventilation around the product  and check that the ventilation vents are not blocked    Ensure that the required voltage does not exceed the product s capacity    Transport and Storage   Ensure that the mains power and battery leads have been disconnected before storing or transporting  the product     No liability can be accepted for any transport damage if the equipment is shipped in non original  packaging     Store the product in a dry environment  the storage temperature must be between  20  C en 60  C     Consult the battery manufacturer s manual in respect of transport  storage  charging  recharging and  disposal of the battery     victron energy  MO     TABLE OF CONTENTS      INTRODUCTION      INSTALLATION F   2 1 Placement of the inverter  in  2 2 Using the  Remote O
12. iarise yourself with the safety features and instructions by first reading the documentation  supplied with this product before using the equipment  This product has been designed and tested in  accordance with international standards  The equipment must be used exclusively for the purpose for  which it was designed     WARNING  ELECTRIC SHOCK HAZARD    The product is used in conjunction with a permanent energy source  battery   Input and or output  terminals may still be dangerously energised  even when the equipment is switched off  Always switch  off the A C supply and the battery before carrying out maintenance or servicing the product     The product has no internal user serviceable components  Do not remove the front plate or operate  the product if any panels have been removed  All servicing must be undertaken by qualified personnel     Never use the product where there is a risk of gas or dust explosions  Consult the battery  manufacturer s information to ascertain that the product is intended for use in conjunction with the  battery  Always comply with the battery manufacturer s safety instructions     WARNING  Do not lift heavy loads without assistance     Installation  Read the installation instructions in the user manual before switching on the equipment     This is a Safety Class   product  supplied with a protective earthing terminal   Uninterruptable  protective earthing must be provided at the AC input and or output terminals  An additional earth point  is loc
13. inverter abuse like  reverse polarity of battery connections  Both fuses can be accessed by removing the cover of the  enclosure as described below     BEFORE OPENING THE INVERTER TO REPLACE A FUSE  ALWAYS  DISCONNECT THE BATTERY FROM THE INVERTER FOLLOWED BY  DISCHARGING THE INTERNAL CAPACITORS BY PUSHING THE POWER  SWITCH  OF THE DISCONNECTED INVERTER  IN THE  l  POSITION FOR 10  SECONDS     CAUTION       1  Unscrew the 8 top cover screws  4 on each side  see picture below  to lift the top cover enabling  access to the internal fuses  To make removing the top cover easier  it is advisable to slightly  unscrew the remaining left  and right screws on one side of the inverter     Remove these four screws at both Gently lift the cover upwards  ends of the inverter enclosure                                        2  Now the top side of the main PCB is visible as well as the location of the two fuses  See the    figure below for the fuse locations   UBA             AC Fuse DC Fuse             ra  OEA                                                          victron energy 15  Oy    FUSE TYPES    Model DC fuse    Phoenix 12 1000 5x20mm 10Amp 250V slow blow Pudenz type no  156 5611 6121  125Amp automotive strip fuse    3  The AC side fuse can be replaced by turning and pushing the plastic cap counter clockwise until  the cap releases and can be pulled out  The DC fuse can be replaced by unscrewing the two  nuts  Make sure the new fuse is inserted in exactly the same position as the 
14. ld  Operating temperature range  ambient     voltage and high input ripple voltage  blinking sequences of the red LED  battery voltage and high input ripple voltage  Other indications Overload  red LED   AC Present  blue LED     DC input connection  AC output connection  Enclosure body size  I x h x w   Protection class  Inverter weight  e inverter complies with the following  standards   EN50081 1 Generic Emissions Standard  EN50082 1 Generic Immunity Standard  EN60950   Safety Standard  EN60742 Transformer Standard  Note   the given specifications are subject to change without notice  Measured with resistive load   Non linear load  crest factor 3 1    Cont  output at 25  C 7      Cont  output power at 25  C         Cont  output power at 40  C 7    Peak power   Z    Output voltage   Output waveform   Input voltage  O    O omia      f  ooo Range static     oo Range 1000VA     Efficiency    Maximum    IN   Prom    Automatic standby threshold       gt        17    victron energy  MO     6 2 Declaration of conformity    CE    IMPORTER   Victron Energy  ADDRESS   De Paal 35  1351 JG Almere Haven  The Netherlands  Declares that the following products    PRODUCT TYPE   DC TO AC SINEWAVE INVERTER  MODELS     Phoenix 12 1000  Conforms to the requirements of the following Directive of the European Union    EMC Directive 89 336 EEC    The above products are in conformity with the following harmonized standards        EN50081 1  1994 EMC   Generic Emissions Standard    EN50082 1  1997 E
15. more than  approx  10W  the inverter jumps to the continuous mode immediately  delivering power to the load   When the load is disconnected again  or switched off  the blue LED starts flashing for 4 seconds  and the inverter jumps back to the pulsed output ASB mode  This way the inverter automatically  jumps to a low power  sleep  mode when there is no power demand on the output     Note that some loads like TV video equipment  with standby mode  and alarm clocks need  continuous power so that the ASB mode can not be used    With some small non compensated loads  it is possible that the inverter jumps from continuous  output to pulsed output and vice versa all the time  In this case you have to connect a small  additional load to the AC output     IF THE INVERTER JUMPED INTO AN    ERROR MODE     SEE CHAPTER 3 1   DUE TO AN OVERLOAD OR SHORT CIRCUIT  THE INVERTER WILL  AUTOMATICALLY RESTART AFTER ABOUT 18 SECONDS   In case of a high temperature error  the inverter will automatically restart after it  has reached an acceptable temperature  Right before the inverter will restart  it  will warn you with a short beep    WARNING NEVER SERVICE THE AC CONNECTIONS WHEN THE INVERTER IS STILL  RUNNING IN AN ERROR MODE     THE LARGE BUILT IN ELECTROLYTIC CAPACITORS CAN HOLD   SIGNIFICANT DC VOLTAGE WHEN THE BATTERIES ARE   DISCONNECTED    To avoid sparks or short inverter operation  it is advisable to switch on the   inverter for 10 seconds after battery disconnection  before you transpo
16. n Off  function  2 3 The ground terminal 8  2 4 Battery requirements     2 4 1 Using power supplies instead of batteries   2 5 Connection to the battery    2 5 1 General precautions about working with batteries  2 6 The serial communication port   nd os  2 7 Connecting the load  2 8 Turning on the inverter      SELF DIAGNOSIS SYSTEM   TROUBLESHOOTING    3 1 The blink sequence table    3 2 Acoustical messages       3 3 Troubleshooting guideline      WARRANTY      MAINTENANCE   FUSE REPLACEMENT  5 1 Maintenance  5 2 Replacing fuses      TECHNICAL SPECIFICATIONS   DECLARATION OF CONFORMITY     6 1 Phoenix 12 1000  6 2 Declaration of conformity     victron energy  MO     1  INTRODUCTION    Thank you for choosing a Phoenix DC to AC inverter  The Phoenix inverter series are one of the most  sophisticated inverters available today  With high reliability  efficiency and sine quality as our most  important design goals  the Phoenix inverter series is developed to serve you with safe and trouble  free operation for years     Your Phoenix inverter features an advanced micro processor control system with a MOSFET power  stage and a low loss toroidal transformer  This toroidal transformer in combination with well over  dimensioned power components  ensures very reliable operation  so that extreme overload conditions   like startup of compressors or pumps  can be handled safely     To get optimum feedback from your inverter while operating  a built in diagnosis system will warn you  of sta
17. ng requirements      a  Avoid any contact with water on the inverter  Do not expose the inverter to rain or moisture   b  Do not place the unit in direct sunlight or other high temperature environments  Ambient air    temperature should be between 0   C and 40   C  humidity  lt  95  non condensing   Note that in  some extreme situations the inverter s case temperature can exceed 70   C     victron energy  AO     c  Do not obstruct the airflow around the inverter  Leave at least 10 centimeters clearance around  the inverter  Do not place items on or over the inverter while it   s operating  When the inverter is  running too hot  it will shut down until a safe temperature level is reached to restart the inverter     d  Never use the inverter in locations where there is gas or explosion danger  for example  directly on top of batteries  or close to volatile liquids     e  Do not expose the inverter to dusty environments   2 2 Using the  Remote On Off  function   This Phoenix inverter offers the possibility to connect an external  remote   on off SPST switch   min  6OVDC 1A   The two wires of the external switch must be connected to the terminals blocks    as indicated below  Before connecting an external switch  the factory installed link wire must be  removed first  Make sure that when installing the remote switch  the battery is NOT connected yet     1 2                                                                                          s m         installed ink il a po  
18. pearing    Possible cause   Remedy      Inverter is overloaded Make sure that the total power rating of the  connected equipment is lower than the nominal  inverter power rating     Connected equipment features a bad power reduce the required power consumption of the   factor  cose at sinusoidal currents  load  Please note that for example a computer  load features a bad power factor  which causes  a reduction of the maximum output power of the  inverter by approx  20     Connected equipment causes a short circuit at   Make sure that the connected equipment is not   the inverter   s output broken or malfunctioning  Check if the AC  power cord between the inverter and the  connected equipment is ok  Any physical  damage on the power cord can produce a short  circuit  Be careful in this kind of situations    Connected equipment produces a too large Try to power up connected equipment   inrush current successively  and not simultaneously  Or    The red Error Overload LED stays on at load connect the load first and then turn on the   startup  inverter  Otherwise stop using the connected  load  it   s not suitable to drive it with this inverter       victron energy 13     Oy    PROBLEM    Inverter temperature too high  Cooling down    error keeps on appearing    Possible cause   Remedy      Airflow around the inverter is obstructed Make sure there is at least 10 centimeters of  clearance around the inverter  Remove any  items placed on or over the inverter  Keep the  inverter away
19. previous one  see  picture below   Apply sufficient torque to the nuts so that the spring washers are fully  compressed  but avoid bending the main PCB                                            gt     M5 nut  Flatblade Spring washer  screwdriver     f plain washer  ESS an plain washer  DC FUSE                                                                                              J    AC Fuseholder DC Fuse sideview with correct order  sideview of mounting washers and nuts    4  Place the cover carefully back again  without hitting the internal DC fuse and or frontpanel  printed circuit board  Put all eight screws including the spring washers back in place  Now you  can reinstall your inverter  If the replaced fuse blows again while the inverter is installed  correctly  the unit must be returned for serive to your local distributor     16 victron energy  Oy    6  TECHNICAL SPECIFICATIONS   DECLARATION OF CONFORMITY  6 1 Phoenix 12 1000    TECHNICAL DATA    Phoenix 12 1000    Cont  output at 25   Cont  output power at 25  C  Cont  output power at 40  C  Peak power  Short circuit output current  Output frequency  Admissible cos y of Toad    Input voltage   CO  Nominal 12VDC    Range  static  10 5     16VDC  Range   1000VA 9 7     16VDC  Maximum input ripple voltage   1 3VACrms    Efficiency ANN a  Maximum    Pnom    No load power consumption at nominal  input voltage   No load power consumption at nominal  input voltage in automatic standby mode   Automatic standby thresho
20. rt the  WARNING inverter        3  SELF DIAGNOSIS SYSTEM   TROUBLESHOOTING    3 1 The blink sequence table    This Phoenix inverter is equipped with a self diagnosis system  to inform you about the cause of  inverter shut down  To visualize this  the red Error Overload LED can blink in four different  sequences  The duration  or timeperiod  of this sequence is about 1 second  During this timeperiod  the red LED can blink four times in a row at most  The number of blinks in this time period indicates  the cause of inverter shut down     victron energy 11  AO     12    In the table below you can find out what kind of blinking sequence belongs to which error                             Red LED conditions     O   LED blinking   e   LEDON   O   LEDOFF   Time period  1 second  Type of error   0000 Battery voltage too low or too high   one blink per second    0000 Overloaded or shorted output   two blinks per second    0000 Inverter temperature too high  Cooling down   three blinks per second    0000 Too high input ripple voltage   four blinks per second    e     Overload  output in current limit             IN A  BATTERY VOLTAGE TOO LOW OR TOO HIGH  ERROR  THE  INVERTER WILL AUTOMATICALLY RESTART WHEN THE BATTERY  VOLTAGE IS IN NORMAL SPECIFIED RANGE AGAIN     IN AN    OVERLOADED OR SHORTED OUTPUT  ERROR  THE INVERTER  WILL AUTOMATICALLY RESTART AFTER APPROX  18 SECONDS    IN AN    INVERTER TEMPERATURE TOO HIGH  ERROR  THE INVERTER  WILL AUTOMATICALLY RESTART WHEN THE TEMPERATURE H
21. s from the date of purchase  During this period Victron Energy will repair the defective  inverter free of charge  Victron Energy is not responsible for any costs of the transport of this  inverter     This warranty is void if the inverter has suffered any physical damage or alteration  either internally  or externally  and does not cover damage arising from improper use  attempting to operate the  inverter with excessive power consumption requirements  or from use in an unsuitable  environment     This warranty will not apply where the product has been misused  neglected  improperly installed  or repaired by anyone other than Victron Energy  Victron Energy is not responsible for any loss   damage or costs arising from improper use  use in an unsuitable environment  improper installing  of the inverter and inverter malfunctioning     victron energy  MO     5  MAINTENANCE   FUSE REPLACEMENT    5 1 Maintenance    Your Phoenix inverter does not need any specific maintenance besides checking all DC and AC  connections at least once a year  Check if all nuts and bolts in the electrical system are still  tightened sufficiently and if that cables are in good condition  Keep the inverter reasonably clean  and remove dust fibres gathered at the fan in  and outlets to avoid airflow obstruction     5 2 Replacing fuses    The inverter is equipped with two internal fuses  one on the DC side and one on the AC side   These fuses will only blow in case of serious malfunction and or external 
22. tus optically by different blinking sequences  depending on the error situation  See the  troubleshooting chapter for the blinking sequence table  Also  the inverter will warn you acoustically  before it   s going to shut down due to low battery  overload or high temperature condition  A  bidirectional communication port is available too  for future options like a remote panel or connection  to a network of power system equipment     To get optimum performance and safe operation from your inverter  it must be installed and used  properly  Please read this manual very carefully  especially the warning and caution statements   before installing and using your Phoenix inverter     2  INSTALLATION    2 1 Location of the inverter                                                                                        pas     a  ea EME         3    l  FAN         1 2 3 4 5                                                             1  Ceiling mounting   Only recommended when ceiling is fixed and not  removable  2  Floor mounting   OK    3  Vertical wall mounting  fan at bottom   OK  beware of small objects falling through the  ventilation openings on top    4  Vertical wall mounting  fan on top   Not recommended  reduces inverter capacity due to  insufficient cooling     5  Horizontal wall mounting   OK    For best operating results  the inverter should be placed on a flat surface  To ensure a trouble free  operation of the inverter  it must be used in locations that meet the followi
23. victron ene  AN  y rgy    USER MANUAL  GEBRUIKSAANWIJZING    Phoenix 12 1000       CE    Copyrights    1999  2000 Victron Energy B V   All Rights Reserved    This publication or part thereoff  may not reproduced in any form by any  method  for any purpose     VICTRON ENERGY B V  MAKES NO WARRANTY  EITHER  EXPRESSED OR IMPLIED  INCLUDING BUT NOT LIMITED TO ANY  IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A  PARTICULAR PURPOSE  REGARDING THESE VICTRON ENERGY  PRODUCTS AND MAKES SUCH VICTRON ENERGY PRODUCTS  AVAILABLE SOLELY ON AN    AS IS    BASIS     IN NO EVENT SHALL VICTRON ENERGY B V  BE LIABLE TO  ANYONE FOR SPECIAL  COLLATERAL  INCIDENTAL  OR  CONSEQUENTIAL DAMAGES IN CONNECTION WITH OR ARISING  OUT OF PURCHASE OR USE OF THESE VICTRON ENERGY  PRODUCTS  THE SOLE AND EXCLUSIVE LIABILITY TO VICTRON  ENERGY B V   REGARDLESS OF THE FORM OF ACTION  SHALL  NOT EXCEED THE PURCHASE PRICE OF THE VICTRON ENERGY  PRODUCTS DESCRIBED HERE IN     For conditions of use and permission to use this manual for publication in  other than the Dutch or English language  contact Victron Energy B V     Victron Energy B V  reserves the right to revise and improve its products  as it sees fit  This publication describes the state of this product at the  time of its publication and may not reflect the product at all times in the  future     victron energy  MO     English description Page 4    Nederlandse beschrijving Pagina 19    victron energy  MO     SAFETY RULES    General   Please famil
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Motorola 6802931J79 Cell Phone User Manual    Strain Gage Bridge Amplifier GSV-2 - ME  OneCommand Manager Application for Solaris Release  Lathem PayClock Express Time System User Manual    TANDBERG 7000 MXP User Manual  KOHLER K-3828-RA-0 Installation Guide    Olympus Trip 500 Instruction Manual    Copyright © All rights reserved. 