1. Only legitimated persons are allowed for advanced setting li A Password is needed lil Please refer to Advanced Setting Instruction
2. testee did not blow within 30 seconds tester can select Refuse to confirm the testee refused to do the test or select Test Again to allow testee to do the test again If testee failed to give a valid breath sample tester can select Discontinue to confirm or select Test Again to allow testee to do the test again A passive test can be performed by select Manual during the testee is blowing Test Record Over 10 000 test records can be stored Use or to move to the previous or next record For printing an individual test record select the test record which needs to be printed connect the printer with the device by the cable provided switch on the printer select and the test result will be printed automatically a Setting Date amp Time Set correct Date and Time ii Select Update to confirm Auto Off I Select time limit to turn off the device automatically il Select to confirm Print I Select Auto Print to print the result automatically after each test li Select number of printout copies needed lil Select to confirm IV If last calibration date needs to be shown on the printout select Cal I When the screen displays Calibration Needed send the device for calibration Il A password is needed for calibration to ensure calibration is performed by eligible persons lil Please refer to Calibration Instruction Advanced Setting I
3. ALCOVISOR Mark X User Manual Please read this manual carefully before using Alcovisor Mark X Alcovisor Mark X uses an electrochemical fuel cell to detect and measure the concentration of alcohol vapor in expired breath Although the Alcovisor Mark X is extremely simple to operate it is important that the following procedure is used each time a breath is given Deviation from the proper procedure will not generally affect the result of a test However the integrity and capability of an operator and even the legality of any resulting action could be questioned and brought into doubt if it is found later that the operator did not follow the proper testing procedure PRETEST QUESTIONING some foods and even non alcoholic drinks may contain traces of alcohol which will affect the test result through a mouth alcohol effect To prevent this wherever possible insure that a delay of about 20 minutes has elapsed since taking anything by mouth even medicines which may contain alcohol Even a glass of water prior to the test will cool the mouth and dilute the saliva temporarily reducing the amount of alcohol in the breath and consequently the instrument reading A delay of at least two minutes should take place between the time of last smoked and the test STRUCTURE MOUTHPIECE HOLDER FUNCTION BUTTON A ON OFF BUTTON ENTER BUTTON FUNCTION BUTTON B 12V PORT USB PORT ICON DESCRIP
4. TION o innos o omera Previous Screen Cancel amp Print Screen DETAILED PROCEDURE Screening Test Attach a sampling cup onto the sample port Select the Screening Test icon by Function Button A amp B and Enter Button When displays Please Blow take a deep breath and blow to the sampling cup until BEEP tone stops Alcohol Detected or No Alcohol displays on the display A passive test can be performed by select Manual during the testee is blowing Select 2 to start another test If Alcohol Present use mouthpiece to perform a standard test to obtain an accurate test result with reading NOTE Screening Test is only used for screening tests it is to check whether alcohol is found in the breath sample An accurate test result can only be obtained by standard test NOTE Test records of the screen tests cannot be printed nor stored gr pi i Standard Test Attach a disposable mouthpiece onto the sample port Select the Standard Test icon by Function Button A amp B and Enter Button When displays Please Blow take a deep breath and blow until BEEP tone stops Test result displays on the display If printer is using connect the printer with the device by the cable provided switch on the printer After test result displays select and the test result will be printed automatically O Select 2 to start another test If
Download Pdf Manuals
Related Search
Related Contents
取扱説明書 (1.87 MB/PDF) Sony 2UPC-R154 transfer roll SA-LS-1 Light Sensor User Manual PROCEDURE DE 5 JOURS AXRF RF Subsystem and AutoCal Unit Getting 局所洗浄用セット - 川澄化学工業株式会社 Manual del usuario 取扱説明書 Copyright © All rights reserved.
Failed to retrieve file