1. Implementation regulation of energy efficiency label for room air conditioners 1 General provisions 1 1 The implementation regulations are developed according to Rules on the administration of Energy Efficiency Labeling hereinafter referred to as the Rules 1 e the No 17 Order issued by National Development and Reform Commission NDRC and General Administration of Quality Supervision Inspection and Quarantine of the People s Republic of China AQSIQ 1 2 The Regulations are applicable to application registration and publication of energy efficiency label hereinafter referred to as the Label for motor driven compressed refrigerators with the capacity of 500L and below for air cooling condenser complete shut off electromotor compressor room air conditioners with 14 000 W and below under climate T1 The regulations are not applicable to movable VFER or VRF air conditioners 2 Form and Specification 2 1 The label is a colorful one with blue and white background 109 mm long and 66 mm wide 2 2 The label title is Zhongguo Nengxiao Biaoshi English title CHINA ENERGY LABEL and includes content below 1 Manufacturer s title or abbreviated title 2 Product specification and model 3 Energy efficiency grade 4 Energy efficiency ratio 5 Cooling capacity W 6 Power input W 7 Serial number of the relevant national standard for energy efficiency 2 3 Refer to Annex 3 for details 3 Energy effici
2. d test report Energy efficiency ratio in the energy efficiency label should not exceed the value range of the corresponding energy efficiency grade 4 5 The currently valid edition of GB 12021 3 of the national standards shall be served as proofs 5 The printing and pasting of labels 5 1 The manufacturer or importer should print labels by themselves and be responsible for the printing quality 5 2 The label should adopt the cooper plate paper weighing 80g or above for printing 5 3 The label shall be pasted with non dry glue No stain shall be left on the surface after its removal 5 4 Every manufactured or imported air conditioner should be pasted with a label and explained in the product user s manual 5 5 The label shall be placed respectively on the front panel of the in door unit fir split air conditioners or on the top right corner of the indoor unit for vertical ones 5 5 The label placed on the air conditioners should comply with stipulations in the article 2 of the rules and the pattern words and color should not be altered The label specification may be amplified according to the stipulations in article 2 1 of the rules 5 6 If the label used in the product user s manual and publicity may be enlarged and decreased according to proportion The label can be printed in black and white but the words in the label should be clear and legible 6 Filing of labels 6 1 The manufacturers or importers should be filed one by one acc
3. ence of the special stamp for test report or the official seal of the inspecting unit shall be invalid 2 The duplicated report without being affixed with the special stamp for test report or the official seal of the inspecting unit shall be invalid Unless approved by the authorizing unit in the written form any part of the report shall not be duplicated 3 The report without signet of chief inspector exam amp check person or approval person shall be invalid and the report should be affixed with the perforation seal 4 The report shall be invalid in case of any alteration 5 In case of any objections to the test report it is required to propose such objections to the inspecting unit within 15 days upon receipt of the report and the overdue objections shall be rejected 6 The authorized institution shall be only liable for the sample test 7 The basis for test and assessment is the current valid edition of the standard quoted by Implementation Rules of Room air conditioners Energy Efficiency Label Testing Report Report Number Page _ of _pages in all Name of Model sample Sar Serial number Grade of of sample samples Site of sample Number of samples Date of sample Cardinal number of samples Original serial number or production date Date of sampling Arrival date of sample Testing criteria Subjected to be Cooling capacity power consumption for cooling and ener
4. ency test 3 1 The testing way of cooling capacity power input and energy efficiency ratio shall be pursuant to the current valid edition of GB 12021 3 3 2 Please refer to appendix Room air conditioners Test Report hereinafter referred to as the test report for the format of the test report 3 3 The manufacturer or importer may inspect products by themselves or authorize inspecting authorities approved by national lab approval committee to conduct test Energy efficiency inspecting lab is required to submit relevant filing material about the inspecting lab and the materials should include personnel capabilities equipment capabilities test management codes etc The authorized institution is required to check and examine the test capabilities of the test lab 4 Remark of the label information 4 1 The name of the manufacturer refers to product brand owner or user assuming legal liabilities for the product 4 2 The product specification model should be complied pursuant to the currently valid edition of GB T 7725 or use serial number of the enterprise and keep consistent with the remark in the product plate 4 3 The energy efficiency grade should be identified according to the energy efficiency grade judging method requirements in the currently valid edition of GB 12021 3 and the test report 4 4 Cooling capacity power input and energy efficiency ratio should be identified according to the currently valid editions of GB 12021 3 an
5. gy efficiency ratio tested Cooling capacity power consumption for cooling and energy efficiency ratio of room air conditioners of XXXX type manufactured by XXXX is tested the testing items should comply with related requirements in GB 12021 3 and the energy efficiency grade is grade X blank space below Test conclusion Seal for test report Yy mm dd Report nunber Page _ of _pages in all Product model Split Unitary Power supply Diphase Triphase Electronic thermal components Yes No Multi pole switch Yes No Coff completely Mechanical temperature controller Yes No Temperature controller and other controllers Yes No Components for protecting purpose under i Yes No abnormal situation Electric control circuit Yes No Non detachable power supply cords Yes No Independent control panel Yes No Line controller Yes No Remote controller Yes No Rated voltage V Rated frequency Hz Rated current A Anti electric shock protection class Waterproof grade Maximum cooling power input W uononysurt pug uondiosop ojduweg Maximum cooling input current W Heating power input of heat pump W without electric heating Heating power input of heat pump W without electr
6. ic heating Heating power input of electrical heating devices W Maximum heating power input W Maximum heating input current W Indoor noise dB A Outdoor noise dB A Other descriptions Report Number Page _ of _pages in all uononnsur pug uondiiosap ajdures The sample plate and photo product external appearance and controlled parts should be attached and the photos should be clear and legible Report number Page of pages in all 7 Actually Assessment Energy Technological Rated Standard f No Test item measured for single efficiency requirements value value value item grade Tested according to the Energy testing methods set out by 1 efficiency rate GB12 21 3 The result shall EER be less than the energy efficient limit Unit W W Tested according to the testing methods set out by Cooling 2 GB 12021 3 The result shall capacity be less than 95 of the rated value Unit W Tested according to the Power testing methods set out by 3 consumption GB12 21 3 The result shall for cooling be less than 110 tof the rated value Unit W Appendix 2 Room Air Conditioners Energy Efficiency Label Filing Form I The filing party declares Our institution hereby guarantees The energy efficiency label information used is consistent with the filing information The filing in the authorized inst
7. itution is updated when the model product is altered with its energy efficiency label Guarantee the product of this model consistently meets relevant use requirements of the energy efficiency label II Energy efficiency label filing information Name of the manufacturer Product specification and model Item Values Remark Cooling capacity W Power input W Energy efficiency ratio W W Energy efficiency grade III Initial use date The filed label begins to be used since IV Other information Sample description Product model Split U nitary Power supply Diphase Tr iphase Electronic thermal components Z o Multi pole switch Coff completely Z Mechanical temperature controller Z Temperature controller and other controllers Z Components for protecting purpose under abnormal situation Z Electric control circuit Z Non detachable power supply cords Z Independent control panel Line controller Z Remote controller Z Z ojloj jojoljo Rated voltage V Rated frequency Hz Rated current A Anti electric shock protection class Waterproof grade Maximum coo
8. ling power input W Maximum cooling input current W Heating power input of heat pump W without electric heating Heating power input of heat pump W without electric heating Heating power input of electrical heating devices W Maximum heating power input W Maximum heating input current W Indoor noise dB A Outdoor noise dB A Applicable area m Heating capacity W Heating power input W Coefficient of performance COP W W Unitary or indoor Outdoor Appearance size lengths x width x height mm Refrigerants name Perfusion amount of refrigerants kg Extended model information Energy eds uk Cooling capacit f Energy Ne eaters vy Powerinpue cw efficiency ote cicncy i and model wW ratio W W grade Filing party affixed with the official seal Date
9. ording to the models of the product No test report is required for product with the same cooling system and energy efficiency ratio 6 2 The manufacturer or importer should submit the Room Air Conditioners Energy Efficiency Label Filing Form See Appendix 3 via letters and submit related filing materials stipulated by the Method within 30 days upon using the label and fill in related filing information on China energy efficiency label website www energylabel gov cn at the same time The filing materials should be complete and truthful 6 3 In case of any changes about the product filing information it is required to file again in the authorized institution 6 4 The authorized institution should finish label information check amp exam and filing work within 10 workdays upon receipt of the filing materials the time for manufacturer or importer to supplement materials will not be counted As for those pursuant to the requirements in article 6 2 of the rules the authorized institution should register label information file documents make filing number and announce on China energy efficiency label website As for those not pursuant to the requirements in the article 6 2 of the rules the authorized institution shall inform the manufacturer or importer of supplementing materials or replacing the used label in a timely way 6 5 The manufacturer or importer should submit the report on label use status in the previous year to the a
10. uthorized institution prior to March 15 every year The Report should include main content as follows label filing status of all models label supervision and punishment status label use status and other relevant energy efficiency label materials 6 6 The materials in foreign language should be accompanied with Chinese version and the latter shall prevail 7 Label announcements 7 1 As for the enterprises passing the filing check the authorized institution should announce the label information of the filed products on China energy efficiency label website and publish the label information of the filed products in related media periodically 7 2 Announce the filing information according to the label filing number 7 3 The authorized institution should build a product energy efficiency database provide information inquiry services about product energy efficiency for manufacturers and consumers and announce the label check supervision and test status in time 7 4 The authorized institution will accept the complaint concerning the label from manufacturers and consumers telephone 010 58811738 Appendix 1 Room Air Conditioners Energy Efficiency Test Report Report number Testing body with seal Tested by date Reviewed by E date Approved by date Product name Model specification Manufacturer Trademark Authorizing unit Factory Notes 1 The report with abs

Download Pdf Manuals

image

Related Search

Implemen.. implement.diy.hrms implement.dk implement.dyhr implement.diyhr.in/3iinfotech-ss implement.html implement.3i login implement implement synonym implement.3i infotech

Related Contents

Sony CDX-GT260MP Limited Warranty  Service Manual  Plus d`heures sup ? Non merci ! mode d`emploi  AB 1771 IFE User Manual - Artisan Technology Group    E-A-RTONE® 3 A  Socket Mobile E300 User's Manual  For Dummies CompTIA A+ Certification All-In-One, 2nd Edition  User Manual - PMC Rentals  Cher Soft Secrets  