Home
GB PKN10 serial node with colour LCD display User`s manual
Contents
1. Format BMP 320 x 240 16bit RGB565 b Input2 Name input2 bmp Format BMP 320 x 240 16bit RGB565 C Input3 Name input3 bmp Format BMP 320 x 240 16bit RGB565 d Input4 Name input4 bmp Format BMP 320 x 240 16bit RGB565 e Background Name background bmp Format BMP 320 x 240 16bit RGB565 f Logo Name logo bmp Format BMP 220 x 60 16bit RGB565 g Other images Name not significant Format BMP 320 x 240 16bit RGB565 e Wav files PKN10 device checks wav files on the SD card at start up for the voice announcer These files should have a specially assigned name and format Format can be 16kHz 8 bit mono or standard CD format 44 1kHz 16 bit stereo Assigned names for wav files SEC Electronics PKN10 V0 3 page 8 GB Lift status Floor S00 up wav elevator going up FO1 wav floor 1 SO1 down wav elevator going down F02 wav floor 2 S02 open wav doors opening na S03 close wav doors closing F32 wav floor 32 SO4 maxload wa maximal load reached S05 overload wav lift overloaded S06 error wav out of service S07 gongi wav single gong up S08 gong2 wav double gong down Important are only the first three characters Sxx for lift status and Fxx for floor and file type wav Configuration file The configuration file is a text file and can be edited with Windows Notepad Settings in this file are shown in the local configuration except for the out of service text and the floor display
2. firmware update was successful there will be a sign Firmware upgrade OK please turn PKN10 ON OFF and you would be returned to the upgrade setting To make the firmware update make effect switch off the device and turn it back on SEC Electronics PKN10 V0 3 page 7 GB MicroSD card contents e PKN10 cfg configuration file contents is described below If present it is compared with device configuration in FLASH In case they are different configuration from card is copied to FLASH That means this file or micro SD card shouldn t be present if the configuration is changed locally with pushbutton Changes will be deleted at the next power up in this case e PKN10firmware bin file with a PKN10 firmware upgrade It is prepared from hex file with a PKNO9make exe software tool Firmware is changed only when this is requested in the local configuration e PKN10font bin file with fonts and symbols It is prepared from monochrome bitmap fonts with the PKNO9make exe tool It is usually upgraded together with the firmware The upgrade shall be enabled in the local configuration e BMP images PKN10 device checks bitmap image files on the SD card at start up so that those images can be shown as a screensaver background logo or a slide show If an image has a name input1 bmp then these image will be shown if input 1 is active and the same goes for input2 3 4 Image format and name specification a Input Name inputl bmp
3. table 1 my floor O Not active travel direction is shown according to the controller settings 1 48 PKN10 shows direction only when car is in the preset station 2 display starts at the floor Default floor table is 2 1 O 1 48 display offset can be set with this parameter Setting 1 means that 2 is displayed in the lowest station setting 2 means that 1 is displayed in the lowest station and so on This function works with the changed floor table too see parameter floor01 floor48 3 inputi Input I1 function definition not active in PKNO6 compatible mode 0 Not active 1 Fire alarm door A 2 Fire alarm door B 4 input2 Input I2 function definition not active in PKNO6 compatible mode 0 Not active 1 Fire alarm door A 2 Fire alarm door B 5 input3 Input I3 function definition not active in PKNO6 compatible mode 0 Not active 1 Landing door control 2 Fire fighter key SEC Electronics PKN10 V0 3 page 9 10 11 GB input4 Input I4 function definition not active in PKNO6 compatible mode 0 Not active 1 Landing door control 2 Fire fighter key slave mode Slave mode has to be active in case of more then one PKN10 device in the same floor O Not active setting for the first or the only PKNOO9 device in the same floor 1 Acts as a slave setting for the second or the third PKN10 device in the same floor pknO6 compatible 0 Serial line protocol is ada
4. D card 2 Bitmap images are changed in intervals preset by parameter slide show delay SEC Electronics PKN10 V0 3 page 10 16 17 18 19 20 GB screen saver delay 0 Screensaver function is not active current floor is shown all the time 1 3600 Time of lift inactivity before screensaver is activated Inactivity means that information shown by display is not changed slide show delay Image change interval 0 Slide show is not active 1 90 Image change interval for proper operation parameter screen saver must be set to 2 and screen saver delay to 1 second or more background transparency color selects which color is considered transparent is replaced with background image for logo and arrows 0 Off 1 Black is transparent 2 White is transparent emergency light Selects display behaviour on battery power 0 normal operation shows background image and communication error 1 emergency light mode shows only white blank screen and date time to maximise car illumination floor01 floor48 Floor designation name table from station 1 to 48 Name can be one or two characters long allowed characters are 0 9 A Z C S Z C Parameter can t be set in local configuration Colours can be selected from a predefined O to 7 palette or in 16 bit RGB format as hex constants Bits 15 11 are for blue bits 10 to 5 for green and bits 4 to 0 for red Examples 0x0000 black OxFFFF w
5. GB Osec electronics GB PKN10 serial node with colour LCD display User s manual Bac 49a 6253 KneZak SLOVENIA tel 386 5 753 2006 fax 386 5 753 2007 email sec electronics siol net http www secelectro com SEC Electronics PKN10 V0 3 page 1 GB PKN10 Serial node with colour LCD display Features 5 7 colour LCD display with adjustable indication and background colour Car position and travel direction indication time and date indication colour image can be used for background when lift is idle images can run in a slideshow logo image can be shown all the time when input1 4 is active an image can be show with a predefined image name Voice announcer with microSD card Additional relay output for emergency call disable when doors are open Terminals for two pushbuttons with call indication speaker output emergency light battery and four additional inputs Connector for output direction indicators Call button illumination Customizable floor display tables Serial communication compatible with all SEC controllers 145 0 132 7 L 5 0 I N J nnnnn J E O soon 9 9 ooon 9 oona o n 0000 99 0000 e ooo o o C LO SE ST Oo N oO o OO T o LA em e O D m O Ln oo gungngguunuugd 9o nn i me I 119 3 140 0 150 0 Figure 1 PKN10 simplified front view with dimensions all in mm SEC Electronics PKN10 V0 3 page 2 GB Technical specific
6. ameters on the PKN10 device are preset in the factory so additional settings are not necessary If changes are required the procedures are described in the following chapters The Chapter on Local configuration is intended for all users while the chapter about Micro SD card contents is intended only for advanced users Its use is only necessary to access some advanced device settings Local configuration PKN10 device configuration can be made locally with three pushbuttons on the back side To enter the Main menu press the OK button Local configuration consists of four options 1 Set date time 2 Parameters 3 Diagnostic display 4 Upgrade from microSD SEC Electronics PKN10 V0 3 page 6 GB With the UP and Down buttons navigate to the desired configuration and then press OK button to enter To exit the configuration navigate to exit and press OK button Set date time to change the time navigate to set time and press OK With the UP and DOWN buttons set the desired hour and press OK to move to minutes Repeat the procedure for minutes and seconds When you set the seconds and press the OK button you will return to the date time setting To change the date navigate to set date and press OK With the UP and DOWN buttons set the desired day and press OK to move to month Repeat the procedure for month year and day of week When you set the day of week and press the OK button you will return to the date time settin
7. ations Display size 115 mm x 82 mm Supply voltage 24 V DC 15 Unit size 145 mm x 150 mm x 35 mm Supply current max 200 mA idle with backlight on max 350mA when charging battery unit only without load on the outputs Degree of protection IPOO EMC EN12015 in EN12016 Approvals CE Digital outputs max 100 mA each Audio output 5 W max into 4 ohm Ambient temperature max 45 C gt E cen O 8 BY Be CR2032 Sr5 8 2 58 SSL link SSL link date time zzzzz aN O88 output input battery 65566 i DOO D K2 D QD V vooo I Sooo O BAT10 K10 Je uE Ji 22 S J3 J4 connect SSL CAN bus link input nt termination power and OV D1 can D3 D2 microSD card HE f i L menu B U1 E navigation B B keys B B U2 speaker volume 653 BOTs oo E mM T4 on or ON ON ON ES c o OOzOOoz cc of a Z0 Z20 xx 3 gt O O ao p2 x oun S N Do SEC PKN10 V1 0 U17 5000000000 2 gt oO0a gt rmnnna SCORCH ESS o Ls w o2n2a2 A no LLE E o Figure 2 PKN10 rear view with connections SEC Electronics PKN10 page 3 GB K1 8 pin RJ 45 connector SSL input K2 8 pin RJ 45 connector SSL output K3 5 way 5 08 mm terminal block external 24 V DC power supply and 12 V 1 3 Ah battery connection K5 2 way 5 08 mm terminal block speaker output max 5W min 4 ohm K6 Micro SD card socket K7 10 way 5 08 mm terminal block inputs and outputs see figure 2 and the description b
8. elow K8 6 4 pin RJ 11 connector direction indicator outputs K9 6 way 3 91 mm terminal block emergency call disable relay K10 5 way 3 91 mm terminal block CAN communication link currently not used J1 J2 jumpers to select power supply via SSL closed or external power supply via K3 open J3 J4 CAN bus termination currently not used D1 green LED ON when device is working properly blinking when communication doesn t work D2 green LED CAN communication status currently not used D3 red LED ON when audio output is active D4 green LED ON when Micro SD card is inserted K7 terminal description terminal 1 24 V DC from external power supply terminal 2 call DOWN terminal 3 OV terminal 4 24 V DC terminal 5 call UP terminal 6 OV terminal 7 multifunction input 4 terminal 8 multifunction input 3 terminal 9 multifunction input 2 terminal 10 multifunction input 1 Terminal 1 is in Figure 2 on the left side K8 pinout pin 1 OV pin 2 indicator up pin 3 indicator down pin 4 OV Pin 1 is in Figure 2 on the left side SEC Electronics PKN10 V0 3 page 4 Figure 4 call pushbutton wiring for group operation Figure 4 shows possible call pushbutton wiring in a group an example on the figure is for duplex when each lift has its own serial line with PKN10 Call and display operation is correct in all modes including when one of lifts doesn t work or is switched off Pushbutt
9. g To return to main menu select return and press OK Parameters to change the parameters navigate to parameters and press OK Parameters are displayed line by line as described in the chapter Configuration file The active parameter is marked with a cursor and its value can be changed if you press the OK button and then you can change the value with the UP and Down buttons To return press the OK button again At the end you can choose between two options 1 Discard changes and return no changes will be saved 2 Save changes and return all changes will be saved Diagnostic display has no editable parameters its purpose is for monitoring the current status of the device To exit press OK Upgrade from microSD to upgrade from microSD you first must have valid files on the card as described in the chapter about Micro SD card contents If you would like to update fonts navigate to upgrade font and press OK If your microSD card has a valid font file you would have an option proceed with font upgrade otherwise you would have only cancel font upgrade If the font update was successful there will be a sign Font upgrade OK and you would be returned to the upgrade setting If you would like to update firmware navigate to upgrade firmware and press OK If your microSD card has a valid firmware file you would have an option proceed with firmware upgrade otherwise you would have only cancel firmware upgrade If the
10. hite OxF800 blue 0x07EO0 green Ox001F red A predefined eight colour palette is available in local configuration is O black 1 blue 2 green 3 light blue 4 red 5 violet 6 yellow 7 white SEC Electronics PKN10 V0 3 page 11
11. on backlight E type parameter F17 can be active on one PKN10 only so landing button backlight should be switched off on all other lifts in the group with the parameter F22 SEC Electronics PKN10 V0 3 page 5 GB Power supply 24V DC is usually supplied to PKN10 via SSL serial link from the main controller module However the current that can be supplied via SSL link is limited to 1000 mA due to wiring and connector limitations If jumpers J1 and J2 are removed the module does not draw power from the SSL link and has to be connected to external power supply via K3 It is recommended to use K3 for power supply if you have to use the SSL link to supply power the number of PKN10 modules is limited to a maximum of 2 Please consult SEC Electronics if you have a specific configuration Operation 1 Connect call pushbuttons indicators direction indicators SSL link optional battery and power supply if it is not from SSL link 2 PKN10 performs the start up procedure at power on its progress is shown on the display Device configuration can be changed if a Micro SD card is inserted in the socket Possible contents of SD card are described bellow in chapters Micro SD card contents and Configuration file 3 Symbol X is displayed if the serial communication SSL doesn t work properly with the main lift controller 4 PKN10 device starts normal operation when serial line activity SSL is detected Parameter setting Par
12. pted to PKN10 additional inputs master slave and works only in combination with PKN10 devices and E type CPU B V0 57 or higher 1 PKN10 acts as PKNO6 and can be used together with PKNO6 devices Node devices or older E type CPU B firmware error display Displayed when lift doesn t operate due to an error or it operates in a special mode priority fire fireman maintenance or evacuation drive 0 No entry sign see picture 1 X sign the same as for serial communication error 2 Out of service display default is OS see the next parameter os text Displayed when the lift doesn t operate normally and parameter error display is set to 2 Default is OS can be one or two characters long Parameter can t be set in the local configuration os mode Display mode when lift doesn t operate normally 0 Floor number and error message defined by parameter error display are displayed alternatively 1 Floor number is shown all the time there is no message that lift is not in function 2 An error message defined with parameter error display is displayed all the time There is no information about current car position No entry sign background color 0 7 or 0x0000 0xFFFF see explanation bellow character color 0 7 or 0x0000 0xFFFF see explanation bellow arrow color 0 7 or 0x0000 0xFFFF see explanation bellow Screen saver 0 Off 1 Static bitmap image the first found on the S
Download Pdf Manuals
Related Search
Related Contents
Thank you for choosing this mobile phone SPT SR-1884SS Use and Care Manual Operating Instructions XDJ-R1 - Pioneer Electronics SUPER SIRIO 18-25 CS Copyright © All rights reserved.
Failed to retrieve file