Home
        Sonata 150 ELS User Manual
         Contents
1.    Wipe actuator shaft with oiled rag  DO NOT use WD40 or  equivalent     Check SPACE LINK pivot link and regrease    Check spreader bar tilt frame attachment to SPACE LINK   Remove bolt  amp  regrease  Ensure SPACE LINK and  attachments move freely    Check mast to boom pivot point  remove bolts and lightly  regrease bush and retighten  ensuring free movement at  pivot     A MAJOR SERVICE SHOULD BE CARRIED OUT EVERY 12    MONTHS AS A MINIMUM REQUIREMENT     IMPORTANT  An annual load test to the safe working load  Swi  is required for compliance with AS ISO 10535     2011    SONATA 150 ELS User Manual Page  12    TROUBLE SHOOTING    WARNING TROUBLE SHOOTING SHOULD ONLY BE CARRIED  OUT BY ALLEGRO CONCEPTS AUTHORISED PERSONNEL  FAMILIAR WITH BOTH USE  ELECTRICAL AND MECHANICAL  FEATURES OF PATIENT LIFTING HOISTS     The following is a guideline only to general trouble shooting     Before carrying out any trouble shooting ensure that     v Red emergency stop button is released     Maintenance procedures checked  amp  followed     v  v All cable connections are secure   v    Battery is fully charged     i ot POSSIBLE FAULT ACTION    Warning buzzer sounds within  control box    Battery charger power indicator  LED does not light up     Actuator will not run and no  relay  click is heard from control box     Actuator will not run via  handset  but control box relays click     Actuator cannot lift full load or  runs slow     No response from control box   no clicking of relays is he
2.  Attach push handle assembly with hex bolts supplied with  handle assembly     Attach battery by clipping battery pack on top of control box     Plug the lift actuator cable into port 1 positioned on the  underside of the control box  ensuring it is driven firmly home in  the socket     Your SONATA 150 ELS hoist uses an electric leg adjustment   plug the leg actuator lead into port 2 positioned on the  underside of the control box     Plug the handset lead into the large socket on underside of  control box   See next diagram  ensure alignment of tongue on  handset plug with groove in control box handset connection  port  When aligned press home firmly  A smear of Vaseline on  the o ring may assist if plug is tight    Check operation of lifter via handset  ensuring that the RED  EMERGENCY STOP BUTTON ON THE CONTROL BOX IS  RELEASED  Turn the knob quarter turn clockwise to release     SONATA 150 ELS User Manual Page  6    HOIST OPERATION AND CHARGING  HANDSET    v The handset activates the lift actuator by the use of two low  pressure buttons  protected by a strong plastic cover  These  are symbolised by arrows  diagram   The arrows indicate the  direction of travel to raise or lower the hoist jib  When either  button is released the jib will remain in position     v The SONATA 150 ELS hoist incorporates an actuator  driven leg opening adjustment  Two buttons will be seen on  the handset with arrows and symbolised legs indicating the  direction of travel  This function allows a
3.  eX Do not dry clean     Ia Do not tumble dry     SLING MAINTENANCE AND CARE    WARNING  Prior to use  inspect slings including webbing  straps  and key hole buckles for wear  Examine stitching for fraying   breakage and unravelling     DAMAGED SLINGS SHOULD NOT BE USED     PARTS LIST AND DESCRIPTION    A full parts list is available upon request    SONATA 150 ELS User Manual Page  17    LOG BOOK       Service Type Condition Report       Date        Inspected by           Signature              Action taken  Date                    Service Type Condition Report    Date           Inspected by           Signature              Action taken  Date                       SONATA 150 ELS User Manual Page  18       Service Type Condition Report       Date        Inspected by           Signature              Action taken  Date                    Service Type Condition Report       Date        Inspected by           Signature              Action taken  Date                       SONATA 150 ELS User Manual Page  19       Distributed by     STO    CONCEPTS PTY LTD    30 32 James Street  Lidcombe  NSW 2141 Australia  Phone  02 9749 7812 Fax  02 9749 2144  Email  sales allegroconcepts com au  www allegroconcepts com au    SONATA 150 ELS User Manual Page  20    
4. ATA 150 ELS    v Standard padded spreader bar  v ALLEGRO pivot frame   v Tri hook yoke   v Four point yoke   v Weighing device   The ALLEGRO CONCEPTS range of patient lifting equipment   including lifters  slings and accessories  has been designed  and tested to comply with AS ISO 10535     2011   Hoists for  the transfer of disabled persons     Requirements and test  methods     SONATA 150 ELS User Manual Page  3    IMPORTANT SAFETY CONSIDERATIONS  INTENDED USE OF THE PRODUCT    The SONATA 150 ELS compact mobile patient lifting hoist has been  designed to lift and transfer a less able person with the assistance of  a carer     The SONATA 150 ELS should be used with one of the ALLEGRO  range of patient slings  as assessed by a competent trained person     NB  Not all slings and accessories are compatible with this hoist  If  you are unsure please contact ALLEGRO CONCEPTS     The correct and appropriate use of the SONATA 150 ELS hoist will  reduce the risks associated with manual patient handling  The lifting    transferring task should be assessed  amp  planned by a trained user     SAFETY CONSIDERATIONS   v Ensure that all users read this guide before operating the  hoist    v Do not operate the hoist without training in the safe  operation of hoists  amp  slings  IF INDOUBT DO NOT USE    y Only use slings which have been assessed as suitable by a  competent trained professional    v Read the relevant sling users guide which is provided with  each sling  before use    v Do n
5. SONATA 150 ELS    MOBILE PATIENT LIFTING HOIST    USER MANUAL    G  G  IMPORTANT     Do not use the SONATA 150 ELS PATIENT LIFTING HOIST  Without having first read this manual        CONCEPTS PTY LTD    30 32 James Street  Lidcombe  NSW 2141 Australia  Phone  02 9749 7812 Fax  02 9749 2144  Email  sales allegroconcepts com au  www allegroconcepts com au       CONTENTS    SONATA 150 ELS Overview  Important safety considerations  SONATA 150 ELS Assembly instructions  Hoist operation and charging  Lifting procedures  Maintenance   Trouble shooting  Specifications   Warranty   Slings   Key to symbols   Parts list    Log book    10    12    13    14    16    17    17    18    SONATA 150 ELS User Manual Page  2    SONATA 150 ELS    Overview    The SONATA 150 ELS is designed primarily for domestic use  or a lightweight compact patient lifting hoist    The SONATA 150 ELS whilst being compact  provides  superior patient space through the use of SPACE LINK     technology  The SONATA 150 ELS in fact offers more patient  space than most other larger size lifters  The unique feature of  SPACE LINK    allows a patient to be rotated through 360   at  full lift height  thus making the carers job easier and safer     The SONATA 150 ELS lifting range allows patients to be lifted  from the floor  bed or chair with ease and safety     The SONATA 150 ELS is a powered unit using trusted  industry leading LINAK components  giving a safe working  load  SWL  of 150kg    Options available with the SON
6. ard     Actuator works in one  direction only    Flat battery pack   Faulty battery pack     No mains connection   Internal fuse blown   Battery chargers is defective     Control box is defective   Handset defective    Actuator plug not pushed in to  control box   Actuator defective   Control box defective     Batteries not charged   defective     Load too high for lifter   Actuator motor damaged     Emergency stop button engaged     Hoist battery completely flat   Blown fuse in battery pack   Faulty control box     Handset defective   Control box defective     SONATA 150 ELS User Manual    Recharge battery   Replace battery     Plug into mains   Replace fuse   Repair replace charger     Replace control box     Push firmly into correct port   Replace actuator or control     Chargel replace batteries   Replace actuator     Release emergency stop  button   Charge battery   Replace repair control box     Replace handset   Repair replace control box        Page  13    SONATA 150 ELS SPECIFICATIONS    Safe working load  SWL    Base length   External base width   Internal base width closed   Internal base width open   Maximum internal length   Base width adjustment   Under bed clearance   Minimum height of spreader bar  Maximum height of spreader bar  Hoisting range   Height of centre suspension point   max reach  Lifter weight   Minimum storage height   Patient lift space   Under base height   Maximum hoist reach   Minimum hoist reach   Maximum hoist reach   maximum height  Minimu
7. ating     SONATA 150 ELS User Manual Page  11    GENERAL MAINTENANCE    To prolong the working life of the lifter and for trouble free operation  it is recommended that periodic inspections should be performed  routinely and as often as necessary  Periodic inspections should be  performed by a person who is suitably qualified and well acquainted  with the design  use and care of patient lifting hoists     If inspection reveals that the safety of the hoist is jeopardised in any  way the hoist should be IMMEDIATELY WITHDRAWN FROM  SERVICE  tagged as such and the owner notified     MAINTENANCE GUIDE  amp  CHECK LIST    v  v  v    SANNA     lt     XR R R     lt  lt     General visual inspection of lifter    Check castors are tightly attached to legs    Check castors run  amp  swivel freely  remove any hair  amp  fluff  from axle    Check castor brakes operate efficiently    Over haul castors  amp  pack with grease    Inspect surfaces for scratches  amp  chips   Clean surfacers with a neutral detergent  remove any  adhesive tape with orange or eucalyptus oil    Examine all moving parts and fasteners for wear and fatigue   lubricate and  or adjust as required    NB leg pivot bushes incorporate a Teflon coated pivot bush  which requires minimal lubrication    Check tightness of bolt in leg bushes    Check linkages are secure in leg adjuster ball joints    Check all electrical components for correct operation    Check battery charger operation    Remove dirt  amp  dust from actuator 
8. ll sling  attachments are secure and that the sling is positioned  correctly  Check patient comfort  Lower and realign sling if  necessary     Continue to lift until patient is clear of chair  bed etc   ensuring that during the course of the lift the patient is clear  of any obstructions     SONATA 150 ELS User Manual Page  10    MOVING THE PATIENT    A PATIENT HOIST IS PRIMARILY A LIFTING DEVICE  If possible  always move patients from room to room in a wheelchair or other  transport device  However  If you must move a patient while  supported in a lifter the following are suggested     v    v    Lower the patient so the feet are just off the ground  This  enhances the patients    perception of security     Where possible always pull the lifter rather than push  in  particular when changing direction or steering around  corners     Walk the rear of the hoist around so that it is heading in the  new direction     Whilst manoeuvring in a small or confined area  two carers  will make the job easier     Move the hoist smoothly and avoid abrupt stops and turns to  minimise patient swing     LOWERING THE PATIENT    v    Position the patient over the chair or bed to be lowered onto  and begin the lowering procedure with the handset down  button  Check to make sure the patient remains comfortable  during descent     All General Purpose and Pivot slings have handles sewn  onto the back of the sling  These will assist the carer to pull  back the patient into the correct position for se
9. m hoist reach   minimum height  Turning radius    Weight of heaviest part  Base assembly     SONATA 150 ELS User Manual    150kg  1005mm  605mm  530mm  1010mm  860mm  Electric Adjustment  125mm  340mm  1685mm  930mm  134mm  39kg  1235mm  165  50mm  875mm  445mm  610mm  435mm  1100mm  17 5kg    Page  14    WARRANTY    ALLEGRO CONCEPTS PTY LTD warrants its products to be free  from defects in materials and workmanship under normal use and  service and will within the period stated below  from the date of  purchase  repair or replace without cost to the original customer  any  part assembly or portion thereof which shall be returned to  ALLEGRO CONCEPTS PTY LTD and from OUR inspection shows  to be defective     v Patient lifter including electronics 2 years  Accessories on lifter 2 years  Patient slings 1 year    v  v  v Weighing devices 1 year  v    Batteries 3 months    ALLEGRO CONCEPTS PTY LTD cannot be held responsible for  any personal injury  damage to the hoist or damage to property as a  result of the improper or unsafe use of the product     No warranty claim shall apply where the product or any part thereof  has been modified  varied  altered or damaged either accidentally or  through improper or negligent use    No warranty claim shall apply where the hoist is repaired or serviced  by any persons not accredited by the authorised distributor     Warranty does not extend to items or components which may require  replacement due to normal wear and tear   e g  castors  mo
10. n unrestricted range  of leg adjustment     v The handset is also fitted with a battery indicator light  This  will flash when the batteries reach a maximum discharge of  18 volts  NB the light will only flash when the hoist is under  load     v The connection for the handset is located on the underside  of the control box        a7    Handset Port Leg Actuator        Port 2    SONATA 150 ELS User Manual Page  7    ACTUATOR    The SONATA 150 ELS mobile patient lifting hoist uses a LINAK  single speed actuator with an emergency controlled lowering release  handle   twist red collar located at top of actuator shaft clockwise    This allows the patient to be lowered in the event of a fault in the  hoist or deep discharged batteries     md    kS    CHARGING    The SONATA 150 ELS is supplied with a LINAK external wall  mount charger  This is powered by plugging the 3 pin plug into a  standard 240V ac outlet   To recharge the battery pack  perform the following steps    1  Release battery pack from control box by pulling the handle  on the pack towards you  Use both hands to support the  battery pack when removing nor replacing it     2  Clip the battery pack from the control box onto the charging  unit  ensuring it is seated properly on the charger base    3  Charger will automatically activate the charging sequence    CHARGING INDICATOR DISPLAY    y GREEN mains power on light will be illuminated when  connected to 240 v power supply     v ORANGE LIGHT illuminated indicates batter
11. ot use the hoist if there is any doubt about wear or  damage to the unit  In particular the spreader bar or the  ALLEGRO Pivot Frame    v Do not use the hoist if there is any fraying or stitch damage  to the sling or if the sling is damaged in any other way    v DO NOT EXCEED THE SAFE WORKING LOAD OF THE  SONATA 150 ELS HOIST   150kg    v Ensure when the hoist is in use that the surrounding area is  clear and the person being lifted is clear of all obstructing  objects     Jib  SONATA 150 ELS User Manual Page  4          Mast   3   Q  G L      Padded  Spreader  Bar       Push  Handle    Actuator    Battery  amp   Control  Box    SONATA 150 ELS User Manual Page 5    ASSEMBLY INSTRUCTIONS  SONATA 150 ELS    The ALLEGRO range of patient lifting and transfer hoists are fully  assembled  load tested and certified at the factory before being partially  dismantled for packing and shipping    Use the instructions below as a guide to assemble your SONATA 150    hoist     1     Remove lifter components from protective packing and lay out  on a smooth surface to prevent damage to powder coating on  lifter sub assemblies     Lift the mast assembly and slide into mast holder receiving  socket on base chassis  Ensure the mast assembly is  completely engaged in the mast socket  Tighten the locking  clamp hex bolt to prevent movement between mast and base  chassis     Attach lift actuator to jib  by aligning actuator clevis with actuator  mount bracket  Insert bolt and tighten nylock nut    
12. process     Where possible always pull the lifter for maximum safety and  comfort    Move the hoist slowly to avoid patient swing whilst standing   The hoist should not be used on uneven surfaces or on an  incline greater than 5 deg     Never leave a patient in a sling unattended     Ensure brakes of the chair  bed  trolley that the patient is  being lifted from are locked     The braking castors on the lifter should be off  This allows  the lifter to create its own centre of gravity  C G   over the  weight of the patient  N B  This action may result in the lifter  moving slightly during the initial phase of the lift     GENERAL LIFTING PROCEDURE    The information supplied below is not intended to be construed as a  training manual but as a general guide to lifting procedure only     v  v    Fit sling to patient  REFER TO SLING INSTRUCTION FOR USE      Manoeuvre the hoist around the patient  adjusting the legs to  fit around chair  wheel chair etc  If lifting from a bed ensure  under bed clearance is sufficient to manoeuvre the lifter legs     Lower the spreader bar sufficiently to allow fitting of sling  attachment loops onto the spreader bar hooks  Ensure  spreader bar does not contact with patients face or body     If using the ALLEGRO Pivot Frame  lower the Pivot Frame  sufficiently to allow attachment of the keyhole buckles onto  the Pivot Frame studs     Use the handset to raise the hoist boom enough to take up  the patients weight  At this point stop the lift  check a
13. uldings  and paint work   for which ALLEGRO CONCEPTS PTY LTD nor its  distributors can be held responsible     BATTERIES   Batteries carry a limited warranty from the original manufacturer  which is subject to a stringent wear and tear clause  Any battery  faults due to defect in original manufacture will normally become  apparent within the first two months of use     Any gradual deterioration in performance after this period is normally  associated with fair wear and tear  misuse and accidental damage   and as such is not covered by the manufacturers    warranty     SONATA 150 ELS User Manual Page  15    SLINGS    ALLEGRO CONCEPTS PTY LTD manufactures a large range of  patient lifting slings in both mesh and fabric to suit the ALLEGRO  range of patient lifting hoists  A range of custom made to  specification slings are available on request     SLING SIZES AVAILABLE  e X small      Small   Medium    Large     Xlarge     XX large    MAIN SLING CATEGORIES             General Purpose Sling General Purpose Sling with Head Support             Pivot Sling Amputee Sling    SONATA 150 ELS User Manual Page  16    KEY TO SYMBOLS    The following symbols are used on the lifter and attachments  including the range of General Purpose and Pivot slings     SWL Safe working load  this symbol represents the  maximum load the lifter  sling or attachment is rated to  for safe operation     SLING CARE SYMBOLS    X Do not use bleach  LR Wash at a max temp of      85   Celsius     24 Do not iron 
14. y currently  charging        ORANGE LIGHT will extinguish when battery pack is fully  charged     SONATA 150 ELS User Manual Page  8    SONATA 150 ELS External Charging  Unit    DO       CHARGING DOs  amp  DON Ts    Do charge the battery whenever possible  This will extend the battery  life  A large number of cycles can be obtained from operating on the  batteries  but battery lifetime is reduced with frequent discharging     v    v    v    Do inspect all cables particularly the mains power cable on  the charger for any damage  replace where necessary     Do stow the handset and if fitted with charger  the mains  power cable when transporting the hoist     Do clean the actuators  control box  charger  battery and  handset at regular intervals to remove dust and dirt     DON   T    v    Don t allow the batteries to fully discharge before connecting  to charger  The batteries are a lead acid gel type that can be  trickle charged continuously and have a high current  discharge capacity  The batteries are not the nickel cadmium  type and must not be periodically fully discharged  Battery  life is greatly reduced by deep or complete discharging of the  batteries  Longer lifetime is obtained by maintaining fully  charged batteries     SONATA 150 ELS User Manual Page  9    LIFTING PROCEDURES    v    Carer should be fully conversant and trained in the use of  lifter and sling  This will decrease patient apprehension and  increase their co operation and overall safety of the lifting  
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
取扱説明書  Bionaire BAP9700S User's Manual  Installation Manual - Hytrol Conveyor Company, Inc.  Guía del usuario - Portal del Empleo  Danby DCR033B1BDB User's Manual  DeLOCK Kabel eSATApd  ShTA.exe  Poulan PO19542LT Parts Manual  Agilent 3395/3396 Integrator  Rhino Anschraubpumpen 24:1/48:1 und 32:1/65:1    Copyright © All rights reserved. 