Home
User manual Package Listing CFX-SR-6520
Contents
1. CONTROLLER KEYPAD READER Croskgy 8C 3000 CONTROL STATION User manual 1 Programmable Functions Relay latching or momentary Relay activate independently or together Change Codes 1 master 1000 users amp prox cards SRK 6520 Door open detection 2 Programmable Timers Door relay time 00 99 seconds Alarm time 00 99 minutes 3 Wiring Connections Electric Lock External Bell External Push Switch Magnetic Contacts Alarm 4 Keypad 12 keys 1 Bell button 5 Programming memory Non volatile Eeprom memory IMPORTANT INFORAMTION There are no user serviceable parts contained with in the SRK 6520 access control keypad If holes are to be drilled before mounting onto a wall check for hidden cables and or pipes before drilling Use safety goggles when drilling or hammering in cables clips Every effort has been made to provide accurate information however slight variations can occur We also reserve the right to make changes for product improvement at any time NOTE PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL THE SRK 6520 1 Attach the rear plate to a single or double gang electrical box or secure to the wall firmly with at least three flat head screws 2 When wiring has been completed attach the front cover to the rear plate Figuret Wiring Cable Hamess Figure2 Tamper Switch NVM Reset Pins The front cover can be permanently secured by using the short scre
2. Note Press to save changes and exit engineer programming when all programming has been completed otherwise changes will not be saved Changing Master amp User Codes SRK 6520 In engineer programming mode To change Master code Press 0 new master code re enter new master code Upon acceptance Open LED illuminates and stops flashing Press after changing the master code otherwise unit will disregard the new code and revert back to the factory default code Note the master code must be 4 8 digit number Adding User Codes SRK 6520 To Add User and User Codes SRK 6520 Press 1 user code user identification Note the user identification must be 3 digit number within 000 999 and the user door release must be 6 digit code Adding User Codes amp Cards SRK 6520 To Add Usercards amp codes SRK 6520 Press 1 read card user identification Note the user identification must be 3 digit number if adding more than 1 card read the next card after inputting the 3 digit code forthe previous card when you have finished adding all cards pressthe key 1 card must be 000 up to 999 Then the SRK 6520 control station added a user card it was auto added a user code with 1234
3. password code 1234 this can be modified so that each user has aunique individual 4 digit code Press read usercard user passoword new password re enter new password Using Password Code to release the door Press user passoword Technical Specification DC Supply Voltage Low voltage input 9 14Vdc unregulated Current Consumption 100mA quiescent maximum Door Relay 5Amp 12Vdc Tamper Protection Negative loop normally closed Codes SRK 6520 1 Master 100 codes 1 Master 1000 cards and 1000 codes Keypad 12 keys 1 bell push button 3 LED status indicators Card Types EM or EM compatible Card Frequency 125KHz SRK 6520 Induction Distance 5 15cm SRK 6520 Wiring Connections Electric lock Remote door control Door open detection External door bell External Alarm Memory Non volatile eeprom memory Operating Temperature OC to 60 C 32F to 140F Keypad Housing ABS high impact plastic Dimensions 120mm x 115mm x 23mm Weight 175g Package Listing Name Spec Quantity Remark Digital Keypad SRK 6520 1 UserManual SRK 6520 1 Self Tapping 4 5mm x 27 mm a eect Screws fixing Used for Seep eng O2 6mmx7 5 mm 1 front case Screws and back case Pastern Stopper O6mmx27mm 4 Used for fixing Cable 10pinx 300mm 1 Lroshoy Reliable Durable Affordable CFX SR 6520 a INDOOR STAND ALONE ACCESS
4. Reliable Durable Affordable roskox Delete User Card or Cards SRK 6520 There are 3 options to delete a user card or cards in engineering mode a Press 2 0000 to delete alluser cards b Press 2 read card to delete individual user card c Press 2 user identification number to delete individual user card User Operation Mode SRK 6520 There are 3 different options for user operation mode card only card and password valid code The optioned used is common to all users Press 3 00 valid card only Press 3 01 valid card and password Press 3 02 validcard or password Setting Door Relay Strike Time The door relay output can be operated as either normally opened or normally closed amaximum current of 10 ampere can pass through the relay if used as normally opened or 5 ampere if normally closed The door relay time can be set from 0 seconds to a maximum of 99 seconds The factory default setting is 6 seconds and can be changed through the keypad Press 4 newtimefrom00 99 seconds Setting Alarm Signal Output Time Press 5 new time from 00 99minutes Setting Door Open Detection Press 6 00 todisable thisfunction factory setting Press 6 01 to enable this function In order forthis feature towork door contacts must be connected There are 2 programming functions that work together inthis mode a Ifdoor notclosed after opening keypad buzzer sounds b If door forced open keyp
5. ad buzzer sounds and sends alarm signal Setting Security Arrangement SRK 6520 There are two levels of keypad security available for the SRK 6520 Press 7 01 entered 4wrong passwords in succession the keypad is locked for 10 minutes Press 7 02 entered 4 wrong passwords in succession the keypad activates and alarm signal To disable this feature Press 7 00 factory default setting Setting Security Arrangement SRK 6520 There are two levels of keypad security available for the SRK 6520 Press 7 01 toread 10 invalid cards or valid cards then enter 4 wrong passwords in succession the keypad is locked for 10 minutes Press 7 02 toread 10 invalid cards or valid cards then enter 4 wrong passwords in succession the keypad activates and alarm signal To disable this feature Press 7 00 factory default setting Resetting To Factory Default Setting To revert all settings to the factory default values then the Non Volatile Memory Eeprom must be reset Reset Non Volatile Memory by switching of the power and placing the jumper connector onto the pins 1 amp 2 as per figure 2 After switching power onremove jumper the SRK 6520 will give a beep andis now reset to factory default values Changing User Password Code SRK 6520 Press userpassoword user identification number newpassoword re enternewpassword 11 Changing User Password Code SRK 6520 The factory default setting foreach user
6. w supplied SRK 6520 Printed Circuit Board 1 Unplug thecable harness andconnect the nece ssary cables See Figure 3 2 Tape any wires that are unused 3 Plug the cable harness See Figure 2 4 Attachthe front cover See Figure 1 Terminal Wire Connector 1 Function BELL1 Green Bell Push Button BELL2 White Bell Push Button ALARM Grey Alarm To Door Remote Control Button OPEN Yellow Then Negative D_IN Brown To Door Contact Then To Door In 12V Red 12Vdc sitive Regulated Power Input Negative Regulated GND Black Power Input NO Blue Door Strike Relay N O COM Purple Door Strike Relay Com NC Orange Door Strike Relay N C Do Not Plug Adaptor Our Transformer Into Mains UntilAll Wiring Has Been Completed And The Front Cover Secured Figure2 common power supply connection Siaran Power Supply BELL1 BELL2 ALARM OPEN D_IN 12V Green White Grey Yellow ema Puch Swital Brown Red Black Blue Purple Lt Diode 1N4007 special power connection 7 Sebury Sao Special Power Supply VL ACL Ve ATL iode 1N4007 Ld L LI Diode 1N4007 After all wiring is complete and the unit face plate is attached to the back plate apply 12Vdc power to the unit Ready LED illuminated and accept LED flashing Engineer Programming Mode SRK 6520 Toenter programming mode Press 9999 within 5seconds Ready and AcceptLED illuminated Open LED flashing
Download Pdf Manuals
Related Search
Related Contents
Alpine IVA-D300 CD Player User Manual Hyundai H-CMMD4048 Car Radio OWNER`S MANUAL Operating FM/MW/LW Compact Disc Player FM/MW/LW Mini Disc Player Remote communication manual tract 2013 super menteur Washing Machine User's Manual Waschmaschine Beretta MYNUTE GREEN - "Sos" Assistenza Caldaie Roma Long Range Proximity Card Reader Installation Manual Copyright © All rights reserved.
Failed to retrieve file