Home
WX14 SOFTWARE USER MANUAL for WX14 SATELLITE RECEIVER
Contents
1. D Which user account do you want to use to run this program Current user BSTARKEY 0330 Public User Protect my computer and data from unauthorized program activity This option can prevent computer viruses from harming your computer or personal data but selecting it might cause the program to Function improperly O The following user Figure 4 Wxp User Dialog Copyright Zephyrus Electronics 2013 All rights reserved This document and all information contained herein are confidential and proprietary and may not be copied or transferred in whole or in part to any person not the original recipient without the express written consent of Zephyrus WX14 Software User Project WX14 Satellite Receiver UM 1001 Manual Rev R2 Page 10 14 of the boot loading process will be displayed for each step in the process NOTE MAKE SURE THE RADIO BUTTON Protect my computer and data from unauthorized program activity IS NOT SELECTED OR THE DOWNLOAD WILL FAIL Windows 7 has a slightly different user dialog box as shown below and selecting the OK button is all that is required Once the download is completed a reset command is sent to the microprocessor and once the receiver has re initialized any previous connections should re connect n A SPER ae Map User Account Control x Program name batchisp exe Publisher Unknown File origin Hard drive on this computer V Show
2. Copyright Zephyrus Electronics 2013 All rights reserved This document and all information contained herein are confidential and proprietary and may not be copied or transferred in whole or in part to any person not the original recipient without the express written consent of Zephyrus WX14 Software User Project WX14 Satellite Receiver UM 1001 Manual Rev R2 Page 5 14 2 Hardware Requirements The minimum PC hardware A P4 Processor 512 MB Ram XVGA video 5 MB Hard disk space available gt gt gt Copyright Zephyrus Electronics 2013 All rights reserved This document and all information contained herein are confidential and proprietary and may not be copied or transferred in whole or in part to any person not the original recipient without the express written consent of Zephyrus WX14 Software User Project WX14 Satellite Receiver UM 1001 Manual Rev R2 Page 6 14 3 Software Description The software GUI contains 5 tabbed pages which are used to either control the WX14 receiver or collect status information concerning the performance of the satellite receiver There is one informational tab which is used to display the current revision and data of the software The tabbed pages consist of Status Connections Data Redirect Firmware Update WX14 Settings and the About tab The following paragraphs describes the purpose and capabilities of each of the tabs 3 1 Tab
3. HELLO request was succesful A 2 4 37 Firmware version is 02 00 05 2 4 37 Network Config was successfully read 21 03 2012 4 37 Network MAC was successfully read 21 03 2012 4 Figure 5 WX14 Settings The IP section sets the IP address that the receiver will use for it s Ethernet communications The IP address will be used for both control and data TCP connections Different port numbers should be selected for the control and data ports The standard Mask and Gateway information needs to match the network on which the receiver is connected via Ethernet Use the button labeled GET to retrieve the current IP configuration Use the button labeled Set to save the new IP configuration to the receiver When the SET button is selected to set the IP Port settings a reset command is sent to the receiver so the new settings will take affect The button labeled Reset Board is used to send a reset command to the receiver The button labeled Frontend Auto is used to force the receiver to store it s current configurations to the user EEPROM NOTE THIS FUNCTION IS RESERVED FOR FUTURE RELEASES Copyright Zephyrus Electronics 2013 All rights reserved This document and all information contained herein are confidential and proprietary and may not be copied or transferred in whole or in part to any person not the original recipient without the express written consent of Zephyrus WX14 Softwa
4. z WX14 Software User Project WX14 Satellite Receiver UM 1001 Manual Rev R2 Page 1 14 WX14 SOFTWARE USER MANUAL for WX14 SATELLITE RECEIVER Copyright Zephyrus Electronics 2013 All rights reserved This document and all information contained herein are confidential and proprietary and may not be copied or transferred in whole or in part to any person not the original recipient without the express written consent of Zephyrus WX14 Software User Project WX14 Satellite Receiver UM 1001 Manual Rev R2 Page 2 14 Revision history Revision Description Date Initial Release covers User Software release 1 0 0 25 02 29 12 Changes to user GUI include removing the Data Redirect 03 21 12 page removing the data output selections from the WX14 Settings page additional windows opened for firmware updates to work on both Wxp and Win7 Covers User Software release 1 0 0 26 Copyright Zephyrus Electronics 2013 All rights reserved This document and all information contained herein are confidential and proprietary and may not be copied or transferred in whole or in part to any person not the original recipient without the express written consent of Zephyrus WX14 Software User Project WX14 Satellite Receiver UM 1001 Manual Rev R2 Page 3 14 WN 3 1 TABLE OF CONTENT Introduction eee 4 Hardware RequireMent
5. of data received versus the total number of data blocks received Copyright Zephyrus Electronics 2013 All rights reserved This document and all information contained herein are confidential and proprietary and may not be copied or transferred in whole or in part to any person not the original recipient without the express written consent of Zephyrus WX14 Software User Project WX14 Satellite Receiver UM 1001 Manual Rev R2 Page 8 14 3 1 2 Connections The Connections screen is shown in Figure 2 below Use this tab to enable connections to the satellite receiver for either control or receiving data The Control is for monitoring the receiver status and setting certain parameters WX 14 Software TEAR Status Connections Firmware Update WX14 Settings About Enable control connection Ethernet USB Connected Enable data connection Same as control connection Ethernet separate port for data Connected Serial port 21 03 2012 12 34 37 HELLO request was succesful 21 03 2012 12 34 37 Firmware version is 02 00 05 21 03 2012 12 34 37 Network Config was successfully read 21 03 2012 12 34 37 Network MAC was successfully read 21 03 2012 12 34 37 Data output types were successfully read Figure 2 Connections Control connection This section allows the user to select either an IP address and port number or a USB port number
6. to access control of the receiver Using the IP address and port number allows the user to gain control of the receiver from a remote location The USB is used typically for local control of the receiver The USB currently implements a Windows USB to Serial driver and will appear in the Device Manager as a serial port Once the correct parameters are entered in the appropriate fields the user can enable the control connection by selecting the check box to the left labeled Enable control connection Data connection This section allows the user to select several options for obtaining data from the receiver If the radio button labeled Same as control connection is selected then the data will be received on which ever port the control port is configured for If the radio button labeled Ethernet separate port for data is selected the data will be received using the same IP address as the control port but on a different port number specified in the Port field If the radio button labeled Serial port is selected the data will be received on the serial port specified in the Com Port field to the left The user can enable the data port selected in the Data connection group by selecting the check box labeled Enable data connection Copyright Zephyrus Electronics 2013 All rights reserved This document and all information contained herein are confidential and proprietary and may not be copied or transferred in whole or in p
7. art to any person not the original recipient without the express written consent of Zephyrus WX14 Software User Project WX14 Satellite Receiver UM 1001 Manual Rev R2 Page 9 14 3 1 3 Firmware Update The Firmware Update screen is shown in Figure 3 below WX 14 Software oh Status Connections Firmware Update w14 Settings About Program 21 03 2012 12 34 37 HELLO request was succesful 21 03 2012 12 34 37 Firmware version is 02 00 05 21 03 2012 12 34 37 Network Config was successfully read 21 03 2012 12 34 37 Network MAC was successfully read 21 03 2012 12 34 37 Data output types were successfully read Figure 3 Firmware Update The Firmware Update tab can be used to update the microprocessor firmware as well as to update the FPGA firmware To update the microprocessor firmware use the following step 1 Select the button labeled MCU Firmware This button should be grayed out if the client code is not connected to the receiver using the USB port This should open a file selection dialog box Navigate to the folder containing the new firmware file that is to be downloaded to the receiver The file name should have the extension hex Once the file has been selected a user dialog box will appear as shown below Windows XP that will ask for permission to run the program batchisp exe A separate DOS window will open and the status
8. atellite signal When in Alignment mode the receivers front LCD panel can be used to align the Satellite dish for best reception 5 Level Indicates the internal voltage level applied to the gain circuits Copyright Zephyrus Electronics 2013 All rights reserved This document and all information contained herein are confidential and proprietary and may not be copied or transferred in whole or in part to any person not the original recipient without the express written consent of Zephyrus WX14 Software User Manual Project WX14 Satellite Receiver UM 1001 Rev R2 Page 7 14 6 Signal Quality Indicates the current quality of the incoming signal 7 Loss Frames Number of frames that could not be decoded 8 Gain Internal RF gain factor 9 Freq Internal oscillator setting EMWIN Data Section This section displays information about the data being received It is only active when the Data port is connected on the Connections tab 1 Good Blocks Displays the number of good blocks received since the last time the display log was cleared using the Clear button located in the bottom of the Data Section 2 Total Blocks Displays the total number of blocks received since the last time the display log was cleared using the the Clear button located in the bottom of the Data Section 3 Quality Display the quality of the of the data received This is based on the number of good blocks
9. bed Pages 3 1 1 Status The Status screen is shown in Figure 1 below WX 14 Software Status Connections Firmware Update W214 Settings About Signal EMWIN Data Good Blocks Freq Viterbi Frame as Total Blocks 191 Mode Normal Align Quality 197 8 Level 1 78 Signal Quality 100 Sig Quality Avg i 99 99 Loss Frames j1 Firmware version 02 00 05 RF Gain 31 FE P version 2 0 0 0 OSC Freq 33 21 03 201 2 14 30 24 HELLO request was succesful 21 03 2012 14 30 24 Firmware version is 02 00 05 21 03 2012 14 30 24 Network Config was successfully read 21 03 2012 14 30 24 Network MAC was successfully read 21 03 201 2 14 30 24 Data output types were successfully read Figure 1 Status Screen Signal section This section displays information about the signal quality The information is displayed only when the control port is connected on the Connections tab Most of this information is used when it becomes necessary to call the factory for technical support 1 Freq Status indicating if there is a lock on the frequency receiving data 2 Viterbi Status indicating the decoding sequence is locked on the receiving data stream 3 Frame Status indicating the frame sync is locked on the receiving data stream 4 Mode Indicates whether the receiver is in Normal receiving mode or in Alignment mode When in Normal mode data is being extracted from the locked on s
10. cccccccccceeeeeeeeeeeeeeaeeeeeeeeeeeeeeaaaaaeeeeeeeesesaaaaaeeeeeeeeeesaaaaeeeeeeeaaaaeeeeeeeeeesaas 5 Software DeSCripliOn casiwsiiiaiiiaiiiaiiiiiaieveieeedividivstavs david vs dasa da ANTEE E vadvevavavaxivavccecdvexccexdvexens 6 Tabbed Pages issia EEEN E ee 6 lt a ed I gt 0 TA rere errr errr ere 6 312 COMMECUONS vsissvsvevevvvatvvavaaiaaaavaaaaaaaaaaaaaea vest veaseada wave evisu vaeetavsts geccdvexdvexdvexdvandecxdecudvcndac 8 31 9 Firmware Update ss sssscsssssessssassancacsreansacasvancansyeansaaargasaneh narran 0404 ASA iDa 9 3 1 4 WX14 Settings cece cece eee eeeceeee eee eee e eee aaeeeeeeeeeeeeeaaaaeeeeeeeeeeecacccccaeeeeeeeeeseeccsneeeeees 11 Xd oT 00 0 EREEREER EREEREER 12 Software File Folder LAyOut cccccecceeeeeceeeeeeeeeeeeeccaeeeeeeeeeseeecaaeeeeeeeeeseeccceeeeaeeeeeeeeeeenunnaeeeeess 13 Others GOCUMENS eccirni sarin N NAANA NRA A NA AERAR NE NERAN NANa SANANA ARASEN AAAA 14 Copyright Zephyrus Electronics 2013 All rights reserved This document and all information contained herein are confidential and proprietary and may not be copied or transferred in whole or in part to any person not the original recipient without the express written consent of Zephyrus WX14 Software User Project WX14 Satellite Receiver UM 1001 Manual Rev R2 Page 4 14 1 Introduction The purpose of this document is to provide an overview of the usage of the WX 14 software and it s capabilities
11. d proprietary and may not be copied or transferred in whole or in part to any person not the original recipient without the express written consent of Zephyrus WX14 Software User Project WX14 Satellite Receiver UM 1001 Manual Rev R2 Page 14 14 5 Others documents Reference Source Description Copyright Zephyrus Electronics 2013 All rights reserved This document and all information contained herein are confidential and proprietary and may not be copied or transferred in whole or in part to any person not the original recipient without the express written consent of Zephyrus
12. details Yes k No Change when these notifications appear Figure 5 Firmware Update The FE FW section is for updating the FPGA firmware To update the FPGA firmware use the following steps 1 Make sure the client code is connected to the receiver via the USB port Select the button labeled Program located in the center FE FW section A file selection dialog box will appear Locate and select the FPGA firmware file with the extension POF to be programmed into the FPGA The status bar will show the progress of the download After the the program is downloaded a manual reset of the receiver will be needed This can be done using the Reset button located on the WX14 Settings page Copyright Zephyrus Electronics 2013 All rights reserved This document and all information contained herein are confidential and proprietary and may not be copied or transferred in whole or in part to any person not the original recipient without the express written consent of Zephyrus WX14 Software User Project WX14 Satellite Receiver UM 1001 Manual Rev R2 Page 11 14 3 1 4 WX14 Settings The WX14 Settings screen is shown in Figure 6 below WX 14 Software HE Status Connections Firmware Update W14 Settings About IP IP 192 168 0 50 Control Port 7002 Mask 255 255 255 0 DataPor 7003 Get ct Gateway 192 168 0 1 MAC 00 50 C2 EF F0 03 Frontend Auto Reset Board 4 37
13. re User Project WX14 Satellite Receiver UM 1001 Manual Rev R2 Page 12 14 3 1 5 About The About screen is shown in Figure 7 below WX 14 Software Status Connections Firmware Update WRI4 Settings About WX 14 Software ver 1 0 0 26 Latest build date 3 20 2012 4 05 51 PM c 2011 Zephyrus Electronics Ltd ll rights reserved Web http zephyrus us E mail mailto supporzephyrus us 21 03 2012 12 57 25 Network MAC was successfully read 21 03 2012 12 57 25 Data output types were successfully read Figure 6 About The About tab displays information about the WX14 software Copyright Zephyrus Electronics 2013 All rights reserved This document and all information contained herein are confidential and proprietary and may not be copied or transferred in whole or in part to any person not the original recipient without the express written consent of Zephyrus WX14 Software User Project WX14 Satellite Receiver UM 1001 Manual Rev R2 Page 13 14 4 Software File Folder Layout When the software is installed the following file folder is created C Program Files Zephyrus WX 14 Software All firmware files are to be stored in a sub directory called isp under the main installation directory Copyright Zephyrus Electronics 2013 All rights reserved This document and all information contained herein are confidential an
Download Pdf Manuals
Related Search
Related Contents
NTK Samsung Samsung B100 คู่มือการใช้งาน benutzerhandbuch k4652nb, k4653nb k4710, k4730 OWNER´S MANUAL Seat system for Power Wheelchair [1] Mode démploi à l'intérieur Operating instructions Sauna Infrarouge Uniden DGA940 Telephone User Manual MCS® 51 Microcontroller Family User`s Manual Service Manual - AS Catering Supplies Recticel Insulation Products RECTICEL INSULATION RECTICEL Copyright © All rights reserved.
Failed to retrieve file