1.                                                                   ww   w           The values stated above aren   t      values  they are gathered by trying new  metals  As the dimensions of the metals increase  there is an increase in the depth as  seen in the ratios stated in the table  If metals remain under the ground for a long  time  in pace of that time they establish a magnetic area and these magnetic areas  radiates as if there are transmitters  By this means  the receiver of the research  antenna ensures detection of the same target in 3 4 times deeper areas        BATTERY AND CHARGER    16 8 V  3 3 A Rechargeable Lithium Polymer Battery  Operating voltage 12 V  16 8 V    16 8 v 500 mA Lithium Polymer Battery Charger  Input 000000      100 240 v   50 60 Hz   180 mA  city mains        22    ACCESSORIES    Condura Plastic totebag    for the whole hardware            Double zippered Condura   plastic carriage bag   Lithium Polymer Battery  reinforced for deep   search coil   Optional     Universal AC charger    System box leather 100   240 Volt  50 and    totebag     Automotive charger   Optional        Warranty Period  2 Years  Note  Battery  bags  headphones and chargers  are not covered by warranty     2                                Fax   90 216 641 61 65    5        info makrodetector  com  WWW  makrodetector  com      gt      gt        i              
2.        3  Deep Search Coil  600x1000 mm  and Carrying Case  Optional     This is the search coil system developed for deep exploration that can be carried by two  persons  There is a separate carrying case for this search coil  This system can only  operate in LCD mode  When sensitivity is set to 60  it will be possible to carry out  exploration easily without affecting from small metal pieces and without any ground  setting        5  Batteries    14 8 V  4 Ampere Lithium Polymer rechargeable batteries   Battery Operating Voltage  Min   12 V   Battery Operating Voltage  Max   14 8 V   Battery Current  4      Battery Life  4 6 hours    6  Battery Charger    It is a device to charge 14 8 V 4 Ampere Lithium Polymer  batteries    Input  AC 100 240 V   50 60 Hz   1A  City mains    Output  DC 12   16 8 V   400 mA   Charge duration  10 hours    7  Carrying Case   It is a case used for transport and storing of the System box  the  360x440 mm Search coil and accessories     8  Headphone    It is the piece that maintains vocal communication between the  detector and the operator  Waterproof speaker on the electronic  system is turned off when using the headphone to enable only  the operator to hear the sound of the detector              11     ELECTRONIC SYSTEM UNIT       GROUND  The key that allows switching to Ground Setting mode in LCD system  mode     SETUP  The key that allows switching to the Settings Menu     DEPTH  The key that enables the device to switch to diameter screen an
3.  RESET lowers the search coil    3 5 cm    parallel to the ground  If the device  receiving negative effects the operator lifts the detector and presses the         button  several times  if the effect is positive the operator presses the         button several  times and presses reset button  then lowers the search coil to 3 5 cm form the  ground  The procedure must be repeated until the ground effect is neutralized  The  device is ground balanced when you do not get to hear any signal when lowering  the search coil for exploring  After the effect is neutralized the operator raises the  detector search coil 8 15 cm above the ground and switches to the explore mode by  pressing the    ACCEPT    button  Stabilizing the detector 8 15 cm from the ground will  give you reliable search results     13    10     40            If there is no ground effect on the device there  is no interaction on the bar that is indicated in  the figure and    Ground Setting 100   Completed    expression is displayed  In this  case the device is ready for exploring and you  may switch to explore mode by pressing the     ACCEPT    button     In case there is ground effect onlthe device an  interaction is observed in the    GROUND  ADJUST    bars that are indicated in the figure   To eliminate this effect press         button for          effect and press         button for         effect  Press          or         buttons until this effect is eliminated  and    Ground Setting 100  Completed     expres
4.  a metal or a mineral source by reading the oscilloscope  right     1  Target is a small metal and close to 5  Target is a large metal and deep   surface             Metal Target Surface Be  Surface           O       2  Target is a couple of small metals        6  Target is a large metal and deeper  close to surface  underground               Surface  gt    Surface   5        3  Target is    couple of small metals        7  Target is a cavity and very close to  slightly deep  surface             Surface                   Surface  at      amp        Metal Target 8    4  Target is a large metal and close to 8  Target is a cavity and deep   surface        Surface  Metal Target    Depth         rf        Surface  5                         17    9  Target is a cavity and deeper 11  If the oscilloscope line draws a  underground  straight line close to center line  it  points that the ground is a high mineral  soil  So  the ground balance needed to  be recalibrated        Surface    Depth    a         10  Target is a metal inside of a cavity   or       phe    Depth    If the signal line increases very sharp and decreases with same velocity there is no need  to calculate depth  Because  this shows that the target is very close the surface   Oscilloscope never draws a straight line while it receives signals from true target  it  always draws sinuous lines  Oscilloscope line is closer the center line when the target is  deep and line is away from the center line when the target is clos
5.  depth during exploring     Press the    DEPTH    key when in explore mode  after the target is detected    First the dimensions of the target should be  determined in depth mode  This operation is  explained in detail with operator help menu   To enter the help menu form a yellow frame  around the    HELP    window by using         and          keys    Press the    ACCEPT    button after forming this  frame    In this menu it is explained to the in detail how  to determine the dimensions of the target    To enter the determined width dimension  place the yellow frame on    Width    by using          and         keys  Press the    ACCEPT    button to  convert the yellow frame to green     19       Commented by computing the ground effe  target      enwitonmental effect andthe distance of       Lenght       ot       He Cr       Enter the    Width    value by using                         keys  Press the    ACCEPT    button after entering  the width value and convert the frame into  yellow    To enter the determined length dimension  place the yellow frame on    Length    by using          and         keys  Press the    ACCEPT    button to  convert the yellow frame to green    Enter the    Length    value by using                         keys  Press the    ACCEPT    button after entering  the length value    Press the    SCAN     button after this operation  and pass over the target again and release the     SCAN    button   After this operation the device presents an     Analy
6.  is electronic and very sensitive  never assemble and  operate before reading the user manual     Do not start searching before making ground settings  It will not be  possible that the device operate correctly unless the ground setup is  made     Do not use any other detector or a device that emit magnetic waves  within 10 m proximity of the device     Prevent the device from abrupt movements and possible shock     Do not expose the search coil to direct heat  do not exert force  during assembly and use     The battery should be decently placed in its casing and care should  be taken                 poles are not connected by a metal pieces     Do not expose the battery to heat   Charge the battery in room temperature   Do not exert pressure on the LCD monitor       Once a month discharge the battery by plugging it to detector and  recharge again in case of enduring the battery life        ACCESSORIES AND COMPONENTS    1  Electronic System Box and Case    It is the part where the detector sockets  headphone socket joystick feed socket and  battery socket are located and where measurement results are evaluated and displayed  on the LCD monitor  There is a carrying apparatus for easy transport of this system        2  General Search Coil  360x440 mm      It is the system that consists of the search coil for general  purposes  There are no LEDs on this system and operator follows  the results on a LCD monitor located on the system box  This  system can only be used in LCD mode 
7. Makro Detector       ince 1996                                   COMPONE NMS                                     4  Electronic System                                       6  Assembly and Charging the Battery                                      7  Using tne LED MOJ Cusco soe                               9  What is Ground Setting and How It Is                                                            12  How Ground Setting 15                                      13  Performing Search with LCD System       15  Reading the                                        17  Ferrous Metal Elimination Function                                                                             18  Getting and Analysis Report by Analyzing the                                                  19  Detection of Target                                                19  Recording and Examination Of                                                                         21                                                                             22  AC COSSON 22                               23    PLEASE DO NOT START ASSEMBLING  OR USING BEFORE READING THE  WARNINGS SECTION        WARNINGS     Some metals that are buried under ground for a long time and rotten like sheet  steel and tin  lead  galvanize etc   May in some cases may give an impression as  gold     Position of metals under the ground influence perception of the device and may  cause an effect as gold or precious metal     Since the device
8. d carry out  depth analysis     RECORD  The key that enables entry to recording screen in addition to recording  the report in report analysis section     RESET  Resets all detector settings  Default Settings  in reference to recent settings  whenever resetting is done                s The minus key            The plus key   SCAN  A key that enables analyzing a target when pressed passing over it     ACCEPT  The key that approves the related function and enable to switch to the  previous menu     ON OFF Switch  The switch that is used for selecting between device turn off  and system selection     LCD  The section that presents data to the operator in LCD system     6    ASSEMBLY AND CHARGING THE BATTERY    1  CHARGING THE BATTERY     Remove the battery from the system box and connect to the charger  When battery is  being charged red LED will lights and when the charging is done green LED will lights  If  there is no battery attached to the charger or the attached battery is fully charged the  green LED lights  After charging  disconnect the battery from the charger and place it into  system box     The charging period required for a fully depleted battery to be fully charged is 7 hours                 2  ASSEMBLY     Search coil is taken off the carrying case and telescopic extension tube is inserted  piece  Nr 1 into piece Nr 2 as shown in the diagram and tighten the sleeve     The search coil is dismounted from the extension tube when packing in the carrying case   Disman
9. d of the device in whatever  mode is it in  The current adjusted sensitivity level is displayed as   on the screen     Select the    SENSITIVITY    mode by pressing         and         keys as described above  After this  mode is selected press the    ACCEPT    button the sensitivity indicator bar will turn from  yellow into green  Adjust the sensitivity level by pressing         and         keys and press     ACCEPT    button  The green indicator bar turns back into yellow  Now the sensitivity  level is adjusted as you desired and you can switch to the previous mode by pressing     SETUP    button     Adjustment of IRON Mode            SETUP    button is pressed for switching the level of IRON mode of the device on and off  in whatever mode is it in  The current IRON mode is displayed as open or closed     You may find more detailed information about the properties of this mode and how it is  used in following sections     Using the RESET Button     When the device is in use some interference may  occur due to the environment or unbalanced search  coil movement  These interferences start to show  on the screen and cause the device to give a sound  alarm  Resetting can be done by pressing the     RESET    button on the system box  By resetting the  effects of interference are eliminated  Resetting  should not be done when the search coil is over the  target  This will cause loss of depth   misinterpretation of received signal and the target become invisible to the device   Re
10. e     Ferrous Metal Elimination Function     The device can enable to filter the worthless metals  by the device and warn the operator if desired  For  this operation    IRON    mode should be off  To  switch off this mode press    SETUP    button when in  explore or ground modes  Select the    IRON    mode  by pressing the         key  After selecting this mode  press the    ACCEPT    button  Place the frame that  turns from yellow to into green on    OFF    and press  the    ACCEPT    button again  After this operation  press    SETUP    button to switch to the previous  mode  Following this step the device will filter worthless metals  To be able to detect  worthless metals again this mode should be switched back to    ON    mode by repeating  above mentioned operation           18    Getting and Analysis report by Analyzing the Target     To get an analysis report by analyzing the detected  target during exploration     e Press the    RESET    button by removing the    search coil off the target after the target is  detected     e Press and hold the    SCAN    button when    passing over the target again slowly  At  that moment the device analyzes the  target     e Release the    SCAN    button after you pass    overt the target     After this operation the device presents the     ANALYSIS REPORT    to the operator  Type of the  metal  magnitude of the target and the ratios of  other environmental effects are received     Detection of Target Depth     For detecting target
11. e device to LCD System     the commutator switch is adjusted to LCD     After the device is switched on the operator makes  the desired language selection by using         and          keys and press    ACCEPT    button to finalize the    language selection     When the device is on the LCD mode the screen  system is enabled and the device detects the  installed search coil and prepares for that search  coil  If no search coil is installed on the device a  warning is displayed on the screen     Coil and System Error Warnings       there is an error in the search coil or in the system     SEARCH COIL FAULT    or    SYSTEM FAULT    warning  lights blink at the bottom of the screen and a sound  alarm is heard to warn the operator after the device  is switched on  In this case the operator should  switch off the device  check the connectors and       The Search Head  Mounted to the Devi    CAVITY METAL IRON VA LUAULE              SCAROM HEAD FALLI       OAVITY METAL IRON VALUAQNLE                     FALLI a             witch on the device again  If the warning persists authorized service should be called     Checking Battery Charge Level     The device switches to    Ground  Adjustment    section after it detects the  search coil  At the bottom of this section  there is an area that indicates battery status and the operator detects battery status by  referring to this area  If the battery is depleted or does not have adequate charge switch  off the device and charge the batterie
12. he operator  as    CAVITY    or    METAL       If the target is a CAVITY  there is a raise on the     CAVITY    bar and decrease in the graph  The    GAVITY METAL IRON VALUARLE    intensity of the    CAVITY    bar is indicated as            on top depending on the magnitude of the  effect of target        15    If the target is valuable metal  there is a raise  both on the    METAL    and    VALUABLE    that is  expressed in   depending on the magnitude  of the effect  The effect of metal can be  monitored in the graph on top of the bars     If the target is worthless metal there is a raise  both on the    METAL       IRON    that is expressed  in   depending on the magnitude of the  effect        When an alarm is received from the device over any point  the device is taken away  from the target and reset in an area where no signal is received and the search coil  is passed over the same target again  If there is increase in the    CAVITY    bar  our  target is a cavity  If there is increase in the    METAL    and    VALUABLE    or    IRON    bar   our target is a metal  If required the    RESET    button is pressed and search coil is  passed over the target once more  This last operation is done to be sure about the  result     16    READING THE OSCILLOSCOPE    Oscilloscope draws plan view of an underground target  It helps us to pre understanding  the shape  quantity and depth of the target  Also it is a very important system that allows    knowing that the source signal is
13. s installing the charger     Adjustment of SOUND Level        SETUP    button is pressed for adjusting the level of sound of  the device in whatever mode is it in        The current adjusted sound level is displayed as   on the  screen           Select the    SOUND    mode by pressing         and         keys as described above  After this  mode is selected press the    ACCEPT    button  the sound indicator bar will turn from  yellow into green  Adjust the sound level by pressing         and         keys and press     ACCEPT    button  The green indicator bar turns back into yellow  Now the sound level is  adjusted as you desired and you can switch to the previous mode by pressing    SETUP       button     Adjusting LIGHT Level           SETUP    button is pressed for adjusting the level of light of the device in whatever mode  is it in  The current adjusted light level is displayed as   on the screen             Select the    LIGHT    mode by pressing         and         keys as described above  After this  mode is selected press the    ACCEPT    button  the light indicator bar will turn from yellow  into green  Adjust the light level by pressing         and         keys and press    ACCEPT    button   The green indicator bar turns back into yellow  Now the light level is adjusted as you  desired and you can switch to the previous mode by pressing    SETUP    button     10    Adjustment of SENSITIVITY Level           SETUP    button is pressed for adjusting the level of soun
14. setting procedure is carried out after the search coil is removed away from the  target        11    WHAT IS GROUND SETTING AND HOW IT IS DONE     In our country land formation and soil composition vary in relation to regions  In some  regions the composition may vary frequently  Sand  lime  red earth with dense mineral  content  rocky formation  etc       These variations in soil composition mislead the detector and cause perception as metal  or cavity  Therefore first we have to launch the soil characteristics of the region to the  detector   s system  Launching these data will block all misleading effects that may come  up from the ground  these will be perceived as misleading signals from the ground  and  thus eliminated     Ground setting is one of the most important provisions of exploration  Therefore the  operator should be a keen observer and should be able to detect variations in the  ground  He has to observe soil compositions continuously to be able to make ground  adjustment again in case misleading signals the device will perceive results from  variations in soil composition     Ground setting is made for the device to recognize the soil and not to be affected by it   Thus the device is not affected from metal or cavity reflections of varying soil  compositions  If ground setting is not properly done it will cause loss of depth and  minerals to be evaluated as metals or cavities  Therefore ground settings should be  made as correctly as possible     Considering 
15. sion is displayed     Vivo a NONE        uU         l    After pressing         or buttons lift the search coil 40 cm above ground and press  the    RESET    button and observe the ground effect by holding the search coil 3 5 cm    above ground  if ground effect persists try to eliminate this effect by pressing         or          buttons        If we are not able to eliminate the ground effect decrease the sensitivity level one  step and repeat the above defined operation     After the ground effect is eliminated you may press the    ACCEPT    button and switch  to Explore Mode     14    PERFORMING SEARCH WITH LCD SYSTEM    After    GROUND    setting is completed     ACCEPT    button is pressed and switched to  Explore Mode            Hold the search coil 8 15 cm above and parallel to the  ground  You can explore by moving the search coil slowly  with a right to left sweeping motion or by walking straight   Try to detect a target by exploring this way     When the device detects a metal or a cavity it  gives a sound alarm and interaction occur on  CAVITY  METAL  IRON and VALUABLE bars  according to the power of the signal  At the  same time the effect of the target can be  monitored on the graph above the bars  Metal  targets are indicated with upper projecting  lines and cavity targets are indicated with  lower projecting lines on this graph     Ground effect that may be formed together  with the target is also displayed on the display   This ground effect is indicated to t
16. sis Report    that indicates whether the  target is METAL or CAVITY  entered dimension  values and environmental effects    Press the    ACCEPT    button to leave this  report    Switched back to Depth mode and switched to  explore mode by pressing the    DEPTH    button     20          Lenght             Hidth  90                              120         Width  90            Lenght  120        AMETER   0 X 120 cm       Recording and Examination of Records     The device can record the analysis reports as  directed by the operator     Press the    RECORD    button after the  report is prepared and save the    Analysis  Report      Press the    ACCEPT    button after you  receive a message on the monitor that  recording is completed    To examine the records later enter the  record menu by pressing the    RECORD     button when in explore mode and you can  examine the records by pressing         and          keys     Press the    ACCEPT    button when in the  record menu  On top of the monitor there  are    Erase record    and    Exit    windows   Use the         and         keys to activate these  windows    Press    ACCEPT    button when there is a  frame around    Exit    window to exit from  the record menu    Press the    ACCEPT    button and approve  the operation when there is a frame  around    Erase record    window to delete a  record     21       TECHNICAL PROPERTIES    Deep Search Coil  General Search Coil   Optional                                                 
17. the general condition of land formation in our country  a ground setting  system is established that will eliminate ground effect on the device     12    HOW GROUND SETTING IS MADE     When the device is switched on it starts with the    GROUND  ADJUST    mode  Ground adjustment should be done before  using the device for correct results  During exploration when  soil composition has changed and when ground adjustment  has to be done again switch to ground mode by pressing the     GROUND    button and re adjust ground settings after  checking existing settings        3 1191 13       Ground Setting Phases    1  When the device is switched on in    LCD    mode  ground  adjustment is displayed automatically                         Ji        A        IYA ONI         2  Lift the search coil 40 cm above ground and press the    RESET     button     3  When in ground mode the effect of ground on the device is  displayed on the monitor as    Ground Effect     This effect will  change when ground adjustment is made   NOTE  The search  coil must be lifted 40 cm above the ground and the RESET button to be pressed in  order to reset previous values  otherwise following results will not be reliable         4  Make sure that there are no metal objects or cavities in the ground where ground  setting will be made  If ground setting could not be adjusted it will be repeated ina  neighboring area     5  The operator lifts the detector search coil    40 cm    above the ground and after  pressing
18. tling is carried out as the reverse of the process described above     CAUTION  Do not take apart the screws that connect the Connecting piece and Search  coil  Take off only the telescopic tube without damaging cable coil and suitably store in    the carrying case   1 2       General Search Coil                Battery       System Unit Deep Search Coil  B        Optional     Headphone                      SEARCH COIL CONNECTION    Transmits the data received from search coil to the Electronic system box  The 5 pin    A     plugs shown in the above figure are connected to socket    A    on the system box     HEADPHONE CONNECTION   Enables signal sound to be switched from external loudspeaker to the headphone  The     B    plug shown in the figure in the previous page is connected to socket    B    on the  system box     BATTERY CONNECTION   The batteries shown in the previous page is located in the direction of the arrow in the  system box and battery compartment lid is closed  The battery is so placed that the poles  on the battery is in contact with the springs mounted in the battery compartment     USING THE LCD MODE    NOTE  The LCD system function of the device can only be used when 360x440mm search  coil and 600x1000mm search coil is installed  Install the 360x440mm or 600x1000mm  search coil to the system box as described in the    assembly    section     The device has two separate systems  One of these systems is the LED  System  the other is LCD System  To switch th
    