Home

Instructions for use / installation of the boso profil

image

Contents

1. Instructions for use installation of the boso profil manager XD Home Powerful software for computer assisted blood pressure control and observation of therapy Compatible with the following blood pressure meters medilife PC2 medilife PC3 BOSCH SOHN GERMANY These instructions for use and installation of the boso profil manager XD Home app ly to version 4 2 0 133 and above Please refer to the readme txt file on the installati on CD for new information The drive letters in these instructions for use are simply examples C for the local hard drive D for the CD DVD drive The path data corresponds to a standard single user installation under the german Windows 7 32 bit operating system and may be different in other operating sy stems or language versions Microsoft and Microsoft Windows are registered trademarks of the Microsoft Corpo ration Table of contents N SEER KS N KA NM N i 4 4 2 id 2 a eh ek Before installation ee ee eene 6 BEE JE Reis Ve EE 6 Operating the software us EER N SR a ik 6 Installing boso profil manager XD Home 7 Converting data from profilmanager 3 ee ee ee ee ee 10 Installing the USB connection cable 12 Start aei ED ED ee RENE IH EE 13 Patient registry for all applications 14 BERE UU T T 14 a Modify button nennen 14 a Deletes DUTTON sito tor ann ne roa Po Pouf 14 Export Import lt e sessies ese Es gee rrr tooth de non tr e
2. selection You can restrict the reading selection to only morning measurements or only afternoon measurements here 26 3 5 2 Period selection V Period 06 04 2005 10 02 2012 v You can select a specific period for assessment among all the readings by selecting a period Click on the arrow symbol in the data fields to open a calendar making selection easier Click on the month or year to change it immediately 4 Juni 2012 N Mo Di Mi Do Fr Sa So 28 29 30 AF 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 1 2 3 4 6 T 2 EIER ee 3 5 3 Time scope selection field This allows you to select the period for which measurements are displayed You have the choice of Auto Day Week Month Quarter or Year Auto is the default setting In this setting the time scope is scaled from the first measurement to the last Right clicking in the diagram allows you to shift the graph horizontally with the mouse 3 5 4 Print button This produces a print out of the pulse pressure profile pulse profile and statistics If you selected PDF file in the printer settings chapter 3 7 3 a PDF file will be created The name of this PDF file is medi pat YYYYMMDD pp pdf where pat patient number YYYYMMDD date of measurement pp pulse pressure reference letter 27 3 6 Statistics registry Patient zen boso PP profile Statistics Patient measurement s
3. 04 2005 30 04 2005 07 05 2005 14 05 2005 21 05 2005 28 05 2005 04 06 2005 11 06 2005 18 06 2005 25 06 2005 all Morning O Afternoon Period 06 04 2005 v 27 06 2005 Time Scope Auto v Print Version 42 0 132 CRC32 7EB8D631 User Sysdba Server local Pattern 50 DB C ProgramData Boso profmanXD f This displays the trend for the calculated mean arterial blood pressure MAP diastole DIA 1 3 pulse pressure PP The pulse trend can be hidden or displayed by the Ctrl P key combination Move the cursor over the measurement to obtain more information about individual readings The date time and reading are displayed in the top left hand corner of the diagram 3 4 1 All Morning Afternoon selection You can restrict the reading selection to only morning measurements or only afternoon measurements here 24 3 4 2 Period selection V Period 06 04 2005 10 02 2012 v You can select a specific period for assessment among all the readings by selecting a period Click on the arrow symbol in the data fields to open a calendar making selection easier Click on the month or year to change it immediately 4 Juni 2012 N Mo Di Mi Do Fr Sa So 28 29 30 1f 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 2 30 1 23 4 56 7 8 3 4 3 Time scope selection field This allows you to select the period for which measurements are displayed You have the choice of Aut
4. afternoon interval periods 34 3 7 6 Profile sub registry Limits Display Draw envelope curve Mark limits In the profile displays Sys Dia MAP PP profile registry an envelope curve line connecting the individual measurements is normally drawn with the limits shown as a horizontal line Both the envelope curve and the limit lines can be hidden 35 4 Warranty provisions Irrespective of statutory warranty rights boso guarantees the software data carrier to be free from material and processing defects for 90 days from the date of purchase In the light of the warranty undertaking given above boso is obliged to replace the data carrier and the software it contains under the following conditions the customer purchaser notifies boso of the defect in writing within 90 days of the date of purchase or the customer purchaser returns the defective data carrier to the dealer or direct to boso at the address below within 90 days boso BOSCH SOHN GmbH u Co KG Bahnhofstr 64 72417 Jungingen Germany boso does not offer any warranty either explicitly or tacitly beyond the warranty undertaking given above 36 5 Limitation of liability a The software is supplied to you on the basis of the current state of development b Irrespective of the provision set out in chapter 4 boso and its dealers accept no liability for risks with regard to the results and performance of the software We bea
5. ailszads 27 3 6 Statistics DUON eina t EG cbe dtr Rank e een cd ad Pu afud 28 3 6 1 Mr Un 23 oU RIO NAR OE AE N EE N ER EE 29 3 7 Settings button in Patient registry ee ee ee 30 3 7 1 Doctor sub registty sss s svo ee annan nnan nenn ee ee ee ee ee 30 3 4 2 Import export sub registry ssssssssssssssse eene eene 31 3 7 3 Printer settings sub registrY ee ee Re ee 32 3 7 4 slaterfaeesubsregisHY sees nde Ee ER RR Ee cnn ddr ea tera ee 33 3 7 5 Limits sub registrY ee ee ee ee ee ee nennen 34 3 7 6 Profile subsr glstty EER ES ertt tte rennen 35 4 Warranty DFOVISIONS ese WEE ee eN Ee ee keen nan pede ea Eae De 36 5 Limitation of liability ee Rae Re Ee AE Re ee ER tenerent 37 6 Explanation of Icons neun 37 Appendix A Extract from GDT record description ses 38 Contents of package 1 installation CD 1 user manual boso profil manager XD Home Minimum operating requirements e Pentium Il or higher e 512 MB RAM Graphics card 100 MB free hard disk space e USB 1 1 interface e Microsoft Windows XP Accuracy of the values displayed Systole diastole puls accuracy of the measuring instruments used Intended use of a medical device Software for representation of the determined values recorded by boso measuring instruments archiving of measured values in a separate database printout of the data for tra
6. file is medi pat YYYYMMDD sys pdf where pat patient number YYYYMMDD date of measurement sys SYS DIA reference letter 29 3 7 Settings button in Patient registry 3 7 1 Doctor sub registry Doctor Name Dr med Mustermann Street Musterstra e 1 City 12345 Musterstadt Telephone 01234 567890 Fax 01234 567 891 The personal details of the doctor treating the patient are entered in the Doctor registry and used to produce the footer in the print out 30 3 7 2 Import Export sub registry 5 Doctor Import Export Printer Settings Interface Limits Profile GDT Import File C temp import gdt m Export File C temp export gdt m V Produce PDF file during GDT export GDT export permanently active including variable file names yyyymmdd_hhnnss If you are using a clinic data processing system that supports the GDT interface this is where the path and file names for export and import files are set You have direct access to the Windows directory structure via the buttons next to the input fields for import and export files For example c prax_edv import gdt Import file clinic DP system export file Export file 2 clinic DP system import file GDT import takes place automatically when you start the program or manually by clicking the Export Import gt Import GDT button if a valid GDT import fil
7. v You can select a specific period for assessment among all the readings by selecting a period Click on the arrow symbol in the data fields to open a calendar making selection easier Click on the month or year to change it immediately A Juni 2012 N Di Mi Do Fr Sa So 29 VA 2 3 5 6 7 8 9 10 12 13 14 15 16 17 19 20 21 22 23 24 26 27 28 29 30 1 3 4 56 7 8 EE v RNRR NIE 3 3 3 Time scope selection field This allows you to select the period for which measurements are displayed You have the choice of Auto Day Week Month Quarter or Year Auto is the default setting In this setting the time scope is scaled from the first measurement to the last Right clicking in the diagram allows you to shift the graph horizontally with the mouse 3 3 4 Print button This produces a print out of the SYS DIA profile pulse profile and statistics If you selected PDF file in the printer settings chapter 3 7 3 a PDF file will be created The name of this PDF file is medi pat YYYYMMDD sys pdf where pat patient number YYYYMMDD date of measurement sys SYS DIA reference letter 23 3 4 MAP profile registry Name B fo Patentno 1 B j E Patient measurement boso Patient PP profile Statistics 09 04 2005 16 04 2005 23 04 2005 30 04 2005 07 05 2005 14 05 2005 21 05 2005 28 05 2005 04 06 2005 11 06 2005 18 06 2005 25 06 2005 160 140 120 100 09 04 2005 16 04 2005 23
8. ault folder is used unchanged Where should boso profilmanager XD be installed k Setup will install boso profilmanager XD into the following folder To continue dick Next If you would like to select a different folder click Browse Atleast 30 1 MB of free disk space is required At the end of installation tick the Install boso USB Driver checkbox to install the USB driver needed for the PC connection cable ass cJ ss Completing the boso profilmanager XD Setup Wizard Setup has finished installing boso profilmanager XD on your computer The application may be launched by selecting the installed icons Click Finish to exit Setup Once you have successfully installed the single user version of boso profil manager XD Home click on the Close button to close the installation screen 1 3 Converting data from boso profil manager 3 Use the Konverter exe program to convert existing data from earlier Firebird databa ses Launch the program either via Windows Explorer from the directory path C Programme Boso ProfmanXD or via the Windows start button selecting the program Transfer data from boso profil manager 3 under the boso profil manager XD Home program group file path in German J boso profilmanager XD E boso profilmanager XD E3 Daten bernahme aus Profilmanage js profilmanager XD deinstallieren profilmanager XD Hilfe The databases to be converted m
9. d o gp ERA Ee si 14 EXPORL EXCEN N EE IE EK N NE 14 Export patient XML ee ee ee ee ee ee ee ee 14 lA DORE patient OM een 15 Miesies PIE c 15 i SOTUNGS haa PUNON i Ese RR ES N EE our REEN ee 16 Print ss DUO EER EE en ER RE Ee Ee RETE 16 Patient measurement application sesse ee ke AR essere ER AR RAGE EE EE 17 Patient registry A 17 Measurements lt s T 17 Delete period button 19 Moore py DUEEOTIa cs ara 19 Manual data Don eicere Er rete se Reg EE sd cero a ut dn 19 aPN elio T T 19 Trasfer data button eene nennen 20 interval limits Buttons kann 21 All Morning Afternoon selection 21 j Beriod selectiODu uu sicot EE SE een ndo su x de 21 Sys dia profile registry 22 All Morning Afternoon selection 22 Penod SCICCUOM REIS ashe ernennen een ve EE 23 Time scope selection field ee ee 23 a EIE DUTON imei ete dogs os ER BE a EER AE ie EER Ee ce E AERE or 23 MAP profile registreer EE ees 24 All Morning Afternoon selection ee ee ee 24 jPeriod SCI CUO Mis sessie ee seke nee ei Re 25 Time scope selection eld 25 Pinta sF 12T ses n ee EE EE DR EE DE 25 PP profile registry ener trt rette ee EE Eg ee ER Ene 26 All Morning Afternoon selection ee ee ee ee 26 Time scope selection eld 27 Perlod SEIECHON ss EER coti EG na Uc DE ie 27 3 5 4 BEINE old ro RE GE opcre repe SR E EXER OE denda E sant
10. data from GDT import all existing data will be assigned to the patient from the GDT import file 2 1 6 Settings button The settings are explained in the sections dealing with particular applications chapters 3 to 5 as they are application specific 2 1 7 Print button Patient data is presented on screen preview printed out on the printer selected under Setup and or in the configured PDF file The Windows standard printer is the default for print outs If you selected PDF file in the printer settings a PDF file will be created The name of this PDF file is pmXD_pat pdf Where pat patient number 3 Patient measurement application 3 1 Patient registry see section 2 1 Patient registry for all applications See chapter 3 7 for Settings button 3 2 Measurements registry Patient eee boso PP profile I 04 2005 04 2005 04 2005 04 2005 04 2005 04 2005 04 2005 04 2005 04 2005 04 2005 04 2005 04 2005 04 2005 13 04 2005 04 2005 14 04 2005 14 04 2005 15 04 2005 15 04 2005 16 04 2005 16 04 2005 17 04 2005 m ono Delete Period Export GDT ono H om m m m o m or m m Tode IL TES Cr OE KA EA EE STAT m m al OMorning Af
11. e is present in the relevant directory GDT export takes place only if the patient being imported from the clinic DP system is active Export takes place automatically when the program is closed down if mea surements have been read in from the device during the current program session or can be performed manually at any time by clicking the Export GDT button in the Measurements registry tic import It is reactivated when the first patient is reselected Data export is also deactivated if no import has first taken place Further informations to the available options Produce PDF file during GDT export and GDT export permanently active see 3 4 2 T Data export is deactivated if another patient has been selected after automa 31 3 7 3 Printer settings sub registry Doctor Import Export Printer Settings Interface Limits Profile Target J Printer Monochrome PDF file 1 c temp Formats for configured printing New V Patient data V PP Sys Dia V Readings Delete Mp ox cne In the Printer settings registry you decide whether the print out should be produced in paper form as a screen print and or as a PDF document once the relevant Print buttons have been clicked while the program is running If you select Printer then the Output Options dialogue appea
12. e the file dpinst_32bit exe present after installation in the directory C Programme Boso profmanXD ftdi as administrator and then plug the USB cable into a free USB port Patient Meier b U S U PP profile statisties Patient no Surname First name Date of birth Place Postal code Remark 18 Mustermann Manfred 13 Accessing the help function Press the F1 key or button to call up these and other instructions for use in PDF format at any time 2 1 Patient registry Click on a patient to select him or her Patients can be sorted by clicking on the header of the relevant column Use the Restore column order function to go back to the original sorting by patient number To do this right click in the header row of the patient table You can search by name via the Search function 2 1 1 New button This sets up a new patient The name and patient number fields must be completed The system will suggest a patient number but you can change this manually 2 1 1 Modify button This alters an existing patient s personal data 2 1 1 Delete button This deletes a patient This process is irreversible all data including measurements from all parts of the application are deleted and cannot be recovered 2 1 4 Export Import button 2 1 4 1 Export Excel exports data for the cur
13. ent has already been performed 3 2 3 Manual data button Additional readings can be added to the active set of readings here 3 2 4 Print button This prints out the list of readings If you selected PDF file in the printer settings chapter 3 7 3 a PDF file will be created The name of this PDF file is medi_pat _YYYYMMDD_m pdf where pat patient number YYYYMMDD date of measurement m measurement reference letter 3 2 5 Transfer data button Connect the meter to the PC Please press the START STOP button on the measuring device Within 3 seconds Once you have clicked on the Transfer data button the START STOP button on the blood pressure meter must be pressed within 6 seconds in order to transfer data from the blood pressure meter Measurements will be transferred from the meter which is connected Please press the START STOP button on the measuring device Reading data Once data has been successfully transferred you can set up a new period or assign the data to an existing period 9 New Period Add new row generate new period 06 04 2005 27 06 2005 medilfe PC3 x Jf ew jJ 20 3 2 6 Interval limits button The limits for morning and afternoon measurements can be defined here The default setting is midnight to 11 59 a m for morning and noon to 11 59 p m for afternoon 3 2 7 All Morning Afternoon selection You can restrict the readin
14. g selection to only morning measurements or only afternoon measurements here 3 2 8 Period selection V Period 06 04 2005 v 10 02 2012 v You can select a specific period for assessment among all the readings by selecting a period Click on the arrow symbol in the data fields to open a calendar making selection easier Click on the month or year to change it immediately 4 Juni 2012 N Mo Di Mi Do Fr Sa So 29 30 31 edad 2 3 5 6 7 8 9 10 13 14 15 16 17 19 20 21 22 23 24 27 28 29 30 1 3 45 67 8 See k wnRobaBb Hi SON 21 3 3 Sys dia profile registry SC Jo Patient measurement boso PP profile I Statistics 09 04 2005 16 04 2005 23 04 2005 30 04 2005 07 05 2005 14 05 2005 21 05 2005 28 05 2005 04 06 2005 11 06 2005 18 06 2005 25 06 2005 09 04 2005 16 04 2005 23 04 2005 30 04 2005 07 05 2005 14 05 2005 21 05 2005 28 05 2005 04 06 2005 11 06 2005 18 06 2005 25 06 2005 This displays the blood pressure trend The pulse trend can be hidden or displayed by the Ctrl P key combination Move the cursor over the measurement to obtain more information about individual readings The date time and reading are displayed in the top left hand corner of the diagram 3 3 1 All Morning Afternoon selection You can restrict the reading selection to only morning measurements or only afternoon measurements here 22 3 3 2 Period selection V Period 06 04 2005 v 10 02 2012
15. nsmission to the doctor 1 1 Before installation You have chosen boso profil manager XD Home a software solution which gives you optimum results with minimum input time It has been deliberately designed to be operated without the usual menu structure based on individual registries This is why the user manual also refers to individual windows and program parts as registries 1 1 1 Data backup To avoid losing data you should back up the profman fdb file from the C ProgramData Boso profmanXD sub directory at regular intervals 1 1 2 Operating the software The program is operated by the mouse PC requirements A Computers used to assess data must comply with the latest version of European standard EN 60601 1 1 2 Installing boso profil manager XD Home To install boso profil manager XD Home start file DA Setup_profmanXDHome exe manually or automatically via the autostart function which runs when you have inserted the CD in doubt start the Setup profmanXDHome exe program with the right T Make sure that you have administrator rights when installing the program if mouse button execute as administrator Select your preferred language for installation screenshot in German a Wahlen Sie die Sprache aus die w hrend der Installation benutzt werden soll The available languages are German English and Hungarian You can change the target folder for installation individually but in most cases the def
16. o Day Week Month Quarter or Year Auto is the default setting In this setting the time scope is scaled from the first measurement to the last Right clicking in the diagram allows you to shift the graph horizontally with the mouse 3 4 4 Print button This produces a print out of the MAP profile pulse profile and statistics If you selected PDF file in the printer settings chapter 3 7 3 a PDF file will be created The name of this PDF file is medi_pat _YYYYMMDD_map pdf where pat patient number YYYYMMDD date of measurement map MAP reference letter 25 3 5 PP profile registry Name aa Patientno 1 B E Patient measurement boso 09 04 2005 16 04 2005 23 04 2005 30 04 2005 07 05 2005 14 05 2005 21 05 2005 28 05 2005 04 06 2005 11 06 2005 18 06 2005 25 06 2005 160 140 120 100 09 04 2005 16 04 2005 23 04 2005 30 04 2005 07 05 2005 14 05 2005 21 05 2005 28 05 2005 04 06 2005 11 06 2005 18 06 2005 25 06 2005 Period 06 04 2005 27 06 2005 Time Scope Auto L Print Pattern 50 DB C ProgramData Boso profmanXD y This displays the trend for the calculated pulse pressure PP SYS DIA The pulse trend can be hidden or displayed by the Ctrl P key combination Move the cursor over the measurement to obtain more information about individual readings The date time and reading are displayed in the top left hand corner of the diagram 3 5 1 All Morning Afternoon
17. ocess 6200 Date of examination 6228 Results table text formatted 6302 File archiving identifier 6303 File format 6304 File content 6305 File reference 38 BOSCH SOHN GmbH u Co KG Bahnhofstra e 64 72417 Jungingen s Germany Phone 49 0 74 77 92 75 0 e Telefax 49 0 74 77 10 21 www boso de mail zentrale boso de Subject to errors and alterations 15 05 2014 39 BOSCH SOHN GmbH u Co KG Bahnhofstra e 64 e 72417 Jungingen s Germany Phone 49 0 74 77 92 75 0 e Telefax 49 0 74 77 10 21 www boso de mail zentrale boso de Subject to errors and alterations 25 08 2014 40
18. r no liability for indirect losses consequential losses loss of earnings losses due to lost or damaged data or other commercial or financial losses c The aforementioned exclusion of liability does not apply to liability under product liability legislation or to cases of deliberate action or gross negligence on our part or on the part of our agents 6 Explanation of icons Read instruction manual Year of manufacture Manufacturer E 20 IN Important advice 37 Appendix A Extract from GDT record description The record types and their field identifiers needed to create the GDT interface of this software are described below Record type 6302 Request new examination Field 8000 record identification 8100 record length 8315 GDT ID of recipient 8316 GDT ID of sender 8410 Testident BDMOO shortcut patient measurement 9218 GDT version number 3000 patient number 3101 patient s surname 3102 patient s first name 3103 patient s date of birth 3105 insurance number 3106 patient s address town 3107 patient s address street 3110 patient s gender 1 male 2 female 3622 patient s height cm 3623 patient s weight kg Record type 6310 Transmit data from examination Field 8000 record identification 8100 record length 8315 GDT ID of recipient 8316 GDT ID of sender 9218 GDT version number 3000 patient number patient identification 8402 Map for a particular device and pr
19. rently selected patient in Excel readable xls format You can choose whatever file name and storage location you like 2 1 4 2 Export patient XML exports data for the currently selected patient in profil manager XD Home readable xml format 2 1 4 3 Import Patient XML imports data for a selected patient The following rules apply to 2 1 4 2 and 2 1 4 3 The transfer path from the transfer file settings is used for incorporation into the clinic s data processing system see next chapter Settings button The file name is made up of the active application and the patient number For example medicus 10 xml stands for patient data for the patient with patient number 10 2 1 5 Import GDT The GDT import file if available is read and the included patient is selected or crea ted If a patient with the imported patient number already exists the following screen appears r i jent Do you want to select this patient Personal Data Other Name Mayer Patient No 10 Forename Franz Insurance No Date of birth 04 11 1970 E N 9 Male dd mm yyyy Female N Address Dimensions street Musterstra e 99 Height 175 5 cm N Ze City 12345 Musterhausen Weight 75 5 kg L T Remarks Muster Patient N U N R f Yes select this patient No use patient data from GDT import Cancel The button Yes select this patient selects the indicated patient With the button No use patient
20. rs when you click on the Print buttons while the program is running You can choose either a print output Printer or a screen view Preview The File function has no significance here If you select PDF file a PDF file is produced The name of this PDF file is created in different ways depending on the application and this process is described in more detail in the individual applications IN You must select at least one medium Printer or PDF file If you select the monochrome option the print will be in black and white If you press the Configured print out printer symbol the print out format configured here will be used and only the selected pages will be printed L3 Patiententkonfigurierter Ausdruck 32 3 7 4 Interface sub registry First available USB connection If the First available USB port option is active the first FTDI USB port under Windows will be used to transfer data If more than one FTDI USB port is installed disconnect the ports that are not needed from the computer or deactivate the option If the First available USB port option is not active the serial COM interface or USB port selected in the port list will be used for data transfer 33 3 7 5 Limits sub registry The limits for the individual periods can be set in order to allow customised assessment The limit settings for morning and afternoon are based on the morning and
21. tatistics 06 04 2005 27 06 2005 Total 00 00 24 00 Morning 00 00 12 00 Readings 157 Arrhythmias recognized 1 Readings 79 Arrhythmias recognized 1 Min Average Min Average 113 160 8 5 Sys mmHg 113 1620 67 93 5 Dia mmHg 69 93 0 70 1 Puls 1 min 60 69 9 115 9 MAP mmHg 95 1160 PP mmHg 27 69 0 Afternoon 12 00 00 00 Readings 78 Arrhythmias recognized 0 Min Average Fall in the afternoon Sys mmHg 131 159 6 Rise in the afternoon Dia mmHg 67 39 Rise in the afternoon Puls 1 min 62 70 2 Fall in the afternoon MAP mmHg 90 115 8 Fall in the afternoon PP mmHg 28 65 6 User Sysdba Measurements for the complete period morning and afternoon periods are assessed separately The total number of readings in the individual periods and the number of arrhythmias recognised are displayed The following values are displayed in the individual columns Min smallest value in the interval in question Mean arithmetic mean in the interval in question Max largest value in the interval in question SD standard deviation in the interval in question gt Limit percentage above the limits that have been set The percentage increase decrease in the afternoon is displayed 28 3 6 1 Print button This produces a print out of the SYS DIA profile pulse profile and statistics If you selected PDF file in the printer settings chapter 3 7 3 a PDF file will be created The name of this PDF
22. ternoon iod 06 04 2005 v 27 06 2005 Version 4 2 0 132 CRC32 7EB8D631 User Sysdba Server local All measurements that have been read in to date for the selected patient are displayed here Both the period and the blood pressure meter with which the series of measure ments was carried out are displayed 17 07 04 2005 07 04 2005 08 04 2005 08 04 2005 09 04 2005 09 04 2005 10 04 2005 10 04 2005 11 04 2005 11 04 2005 12 04 2005 1 EY SEER 3 4 5 678 9 10 The column content is as follows serial numbers of measurements date and time of measurement SYS systolic blood pressure DIA diastolic blood pressure PUL pulse MAP mean arterial blood pressure calculated as DIA 1 3 pulse pressure PP pulse pressure SYS DIA Arr indication of arrhythmia Exclude if you highlight this the measurement will not be taken into account for assessment in the profile and statistics 10 Remark Double click in the measurement line to add a remark to a measurement This opens the remark input field OONAUBRWN Date 06 04 2005 Time 18 26 Sys 144 Remark IE Test Puls 65 MAP 98 PP 69 18 3 2 1 Delete period button This irrevocably deletes a complete set of readings 3 2 2 Export GDT button This generates the GDT export file manually Only available if the GDT import of the active pati
23. ust be on the local system Conversion via the network is not possible Enter a username and password to register with the Firebird database server The default username is sysdba and the default password is masterkey Select the storage location for the profil manager XD Home file in the Target DB profil manager XD Home field Select the storage location of the database you want to convert profil manager 3 Click on the Connect button to connect to the source database Once you have established a connection with the source database start transferring data by clicking on the button of the same name Start transfer screenshot in German 2 Benutzername Sysdba sswort iade 4 Ziel DB profilmanager XD C ProgramData Boso profmanXD profman fdb Daten bernahme aus ABI Daten bernahme aus Profilmanager 3 Quell DB Profman 3 C ProgramData Boso Profman boso_tm pm adb Connect Ubernahme starten Wichtiger Hinweis Die Konvertierung muss auf dem Server durchgef hrt werden Alle Files m ssen sich auf dem lokalen Filesystem kein fwerk befinden 11 1 4 Installing the USB connection cable If the USB driver was pre installed during installation this is normally the case you simply need to plug the USB connection cable provided into a free USB port The cable is then automatically recognised and installed If the driver was not pre installed you must execut