Home

GSM Alarm System S3526 User Manual Ver 1.2 Date Issued: 2009

image

Contents

1. Press the button on the remote control the Control Unit enters arm status under this status any sensor triggered the control unit will alarm and the siren will sound 90S Press the button mi on the remote control the Control Unit disarms immediately under this status any sensor triggered the control unit will not alarm and the siren will not sound except the Emergency Button Press Emergency button on the remote control or Press any Emergency button The Control Unit will enter emergency alarm status The siren will not sound but will alert the pre set phone number immediately 7 2 Arm or Disarm by SMS and Telephone There re two way to operate it Method 1 Send SMS to Arm or Disarm 2 Call to the Control unit In order to operate it easier we designed simply commands as below Arm Disarm Switch ON the relay output for 3 minutes Switch OFF the relay output Switch ON the siren for 3minutes Switch OFF the siren immediately IXXXXNENE NE O the password 7 3 External AC power failure alarm When the system detects a power cut in external AC power for longer then two seconds it will send SMS to the SMS Alert target cell phones when the AC power restored it will send SMS to you without calling King Pigeon Hi Tech Co Ltd Page of20 Ver1 2 File No 35260011 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com 7 4 Handling the received
2. the SMS Command Control functions may not work in all countries elephone and SMS Commands For GSM Alarm System Setup Basic Functions Functions amp Descriptions 1H Set the control unit when triggered The siren will sound Default E g When the control unit triggered the siren will not sound King Pigeon Hi Tech Co Ltd Page of20 Ver1 2 File No 35260011 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com Set wired zone as NC type Set wired zone as NO type Default Modify password The original password is 1234 Setup SMS Alert Telephone numbers Com Functions amp Descriptions Inquire the preset SMS Alert telephone numbers Can t inquire it by telephone only by SMS Set the Hst SMS Alert telephone Number Set the SMS Alert telephone Number Set the SMS Alert telephone Number Setup Call Alert Telephone numbers Com Functions amp Descriptions Inquire the preset Dial phone number Can t inquire it by phone only by SMS Setup SMS Alert Contents C Functions amp Descriptions Inquire the Wired zone Name Can t inquire it by phone t inquire Set the thellst wired zone name Set the 2ndj wireld zone name Set the fist wireless zone name Inquire the wireless zone names Can t inquire it by phone Set the wireless zone name Set the Brd wireless zone name Set the 4th wireless zone name Set the Bth wireless zone name King Pigeon Hi Tech Co Ltd Page o
3. remote control operation information by SMS 12 Equips SOS Alarm button on the remote control for emergency alarm 13 Standby internal rechargeable battery which can last 12 hours King Pigeon Hi Tech Co Ltd Page of 20 Ver 1 2 File No 35260011 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com 14 Based on the GSM communication network and Operation Menu Display technology apply to wide range situations 6 Settings The 83526 designed for easiler setup all the setup can be done by SMS commands Also you can setup it by call the commands are the same as the SMS Commands Before the setting please read the user manual carefully Then insert the SIMCard and fix it well then power on the mainframe the control unit will search and register the GSM Network automatically once the Run Led flashs 1 second and off 3 seconds means the gsm netwok was registered then you can start to set it Also you can set the system by SMS after it finished GSM Network registration Please setup it following the follow table 1 When set the system by SMS if success will return one SMS to confirm otherwise means the setting failure 2 When set the Control Unit by phone the system will request you inout password to enter the system if success will make a long Di sound to confirm if it makes didi sound means the setting failure The operation commands please see tables 3 Depending on the infrastructure
4. separate by more than between 1 5 to 3 0cm Low Voltage Indicator i Double Faced Tape Work Indicator A o Q In some circumstances an Infrared beam fence is more appropriate than magnetic sensors i e veranda picture window balcony boundary wall e t c King Pigeon Hi Tech Co Ltd Page of 20 Ver1 2 File No 35260011 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com For a Scrolling Steel Door a special Wireless Scroll Steel Door magnetic sensor must be used due to interference of the wireless signal caused by the steel door Installation attach the larger half to the floor and attach rivet or glue the smaller half to the scroll steel door An alarm is triggered when the halves Wielas Siqnal Transmitter Scroll Steel Door 8 3 Install the wireless PIR Motion Sensor King Pigeon Hi Tech Co Ltd Page of 20 Ver 1 2 File No 35260011 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com The PIR sensor will detect a person since human temperature is different to ambient temperature When triggered the PIR will signal the Control Unit Apply the detection area illustration below when installing Cs 40 degree Wireless PIR motion sensor 50 degree Surveillance Area 2 1m 5 9m sensor windous infrared 5m 10m infrared Wireless curtain sensor detection area illustration below p 8 4 Instal
5. KING PIGEON GSM Alarm System 3526 User Manual Ver 1 2 Date Issued 2009 06 07 All rights reserved by King Pigeon Hi Tech Co Ltd Website Http www GSMalarmsystem com A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com Table of contents Brief introduction 2 Safety Directions 2 Standard Packing list 3 Physical Layout 3 Features n nnn nnn nnn nnn n nnn nnn 5 SEUNG Aeee n ne nnn nnn nnn nnn nn nen ne 6 Operating Instructions 8 Installation 10 Add wireless Sensors 14 Technical specifications 16 Important information 17 Maintenance 17 Quality Warranty 18 King Pigeon Hi Tech Co Ltd Page of20 Ver1 2 File No 35260011 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com 1 Brief introduction The GSM Alarm System S3526 is a new security protection solution special for home house and office and other applications It based on Wireless GSM Communication network When any sensor activated it will Call amp Send SMS to owners telephone immediately The GSM Alarm System S3526 ca
6. alarm lf the Control Unit receives any alarm signal from any sensors will start the siren intermittently and switch on the relay output At the same time dial the Call alert telephone numbers one by one three times If programmed it will also send SMS to SMS Alert Target cell phones the SMS content will include the zone name If answered the alarm calling you can listen into sounds from the alarm system area After answered the call press 01 to arm press to disarm lf the user hangs up the Control Unit will stop alarm and call other alarm telephones until answered 7 5 Arm disarm and wiretap through telephone You can use any telephone to call the Control Unit after detecting 15 seconds will make click sounds waiting for you to enter the password if the entered password is correct you can arm or disarm it and listen in the control unit area 8 Installation Before installing the control unit and sensors and sirens please help to test the system firstly including wireless sensor wired sensor power supply gsm signal etc 8 1 Insert SIM into Control Unit In the backside of the control unit please install the GSM SIM ard BS Up side downe King Pigeon Hi Tech Co Ltd Page of 20 Ver 1 2 File No 35260011 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com 8 2 Install the Magnetic door window sensors Magnetic door window sensors signal the Control Unit when the two parts
7. f 20 Ver 1 2 File No 35260011 om 70 71 72 80 84H A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com 86 Set the wireless zone name 87 Setthe wireless zone name 88 Set the wireless zone name Send to arm the system or call into the system then enter to arm it Change the password send H234 31 1111 Or call into the system then enter H234 31 1111 Means change the password 1234 to 1111 Set the first dial phone Number 20202020 Send SMS 1234 51 20202020 to the system or call the system then enter 1234 51 20202020 Delete the preset alarm number Send SMS or call the sytsem then enter 1234 51 Will delete the first dial phone number the same format to delete the other alarm phone numbers and SMS alert numbers Send SMS 1234 41 or call the system then enter 1234 41 to delete the first SMS alert number Change the zone name The zone names should less than 12 letters Send 1234 81 door to change the wireless zone 1 name to door Please help to setup the first SMS Alert Number firstly so that you can receive all the confirmation SMS 7 Operating Instructions 7 1 Arm or Disarm and Emergency Alarm by remote controls ireless ANT Disarm Button This Button Useless mergency Button King Pigeon Hi Tech Co Ltd Page of 20 Ver 1 2 File No 35260011 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com
8. isuse by the Operating Instructions In no event shall the manufacturer be liable for any alarm system altered by purchasers The End Any questions please help to contact us feel free Email Us Sales Kingpigeon com cn Http www GS Malarmsystem com Http www Kingpigeon com cn King Pigeon Hi Tech Co Ltd Page of 20 Ver 1 2 File No 35260011 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com Warranty Card Model Product ID Date of Purchase Date of Production Maintenance Record Dealer King Pigeon Hi Tech Co Ltd Page of 20 Ver 1 2 File No 35260011
9. l other sensors For smoke you can use wireless smoke sensor for gas leakage detection you can install gas leakage sensor below King Pigeon Hi Tech Co Ltd Page of 20 Ver1 2 File No 35260011 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com E B a eS ae aL i 8 5 Install the Control Unit In order to avoid destruction of the Control Unit by intruders please install it in a concealed location convenient to the operator If applicable ensure that an uninterruptible AC power outlet is available near the Control Unit First connect accessories to the Control Unit then the AC adapter 8 6 Install Siren Connect the Siren and the Speaker to the Control Unit and fix them in appropriate locations Strobe Siren Siren Linght Siren 8 7 Install Other Wired Sensors Connect the sensors t two cable to the interface 2 is ok the S3022 can supports 4 Wired Sensors so you can add Wired Photoelectric Beams sensors for outter install temperature sensors water leakage sensors wired smoke sensor wired Panic Button Wired PIR Motion Sensors and so on 9 Add Wireless Sensors to the Control Unit The Wireless sensors in the package box are pre coded prior to shipping Add additional wireless sensors to the control units please help to see King Pigeon Hi Tech Co Ltd Page J of 20 Ver 1 2 File No 35260011 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem c
10. ling Door Sensor Temperature Sensors and Other Sensors 4 Physical Layout 4 1 Control Unit physical layout Alarm k Out status Monitor ay a h Charge Powel amp amp Gy E amp x a ge King Pigeon Hi Tech Co Ltd Page of 20 Ver 1 2 File No 35260011 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com External 12VDC Power Status LED power on will on Arm Status LED in armed mode it flashs green always green is disarmed Busy Always red color means the mainframe calling out or sending SMS out or triggered normally it flashs Alarming it will on and the buzzer will make a sound Relay output closed it will on otherwise it is off Microphone working will on otherwise it is off Charge Under charge the internal backup battery it will on otherwise it is off 4 2 8Pin connector definition GSM Network Led flash 1 time per 1 second means searching and registering GSM network Flash 1 second and off 3 seconds means the gsm netwok was registered always on means under the communication Otherwise means the SIMCard hasn t been fixed well or GSM network signal is weakness Alarm Out Monitor 12VDC Power output Wired Sensor inputi 12VDC Power Input Siren Relay Output Wired Sensor Input 2 External Power Switch GSM ANT GHD GHD Interface PNT eo OCS PIN2 Siren positive electrode 12VDC Power Output Source can use it fo
11. n setup by SMS easiler What you need is a SIMCard which supports Call ID function 2 Safety Directions Safe Startup Do not use GSM Alarm System when using GSM equipment is prohibited or might bring disturbance or danger Interference All wireless equipment might interfere network signals of GSM Alarm System and influence its performance Avoid Use at Gas Station Do not use GSM Alarm System at a gas station Power off GSM Alarm System it near fuels or chemicals Power it off near Blasting Places Please follow relevant restrictive regulations Avoid using the device in blasting places Reasonable Use Please install the product at suitable places as described in the product documentation Avoid signal screening by covering the mainframe King Pigeon Hi Tech Co Ltd Page of 20 Ver 1 2 File No 35260011 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com Use Qualified Maintenance Service Maintenance can be carried out only by qualified maintainer Waterproofness The product is not waterproof Please install it at dry places and keep it dry 3 Standard Packing List Control Unit X1 Wireless Magnetic Door Sensor X1 Wireless Remote Controls X 2 Wireless PIR Motion Sensor X1 Wired Mini Siren 110dB X1 Regulated 12vDC Power Supply X1 User Manual X1 Optional Accessories Wired or Wireless Sensors PIR Motion Sensors Glass Break Sensors Magnetic Window Sensors Magnetic Steel Scrol
12. nstall the Control Unit and set the Control Unit 2 Do not install the system in close vicinity with objects that generate strong interference such as TV set and computer Install the system in a hidden place Avoid getting water into the Control Unit 5 Have a secure connection to the main power supply This product was designed for the indoor use Opening the control unit cover will void the warranty 12 Maintenance 1 Incase of failure please contact the distributor or manufacturer 2 If the Control Unit works while the remote control and other sensors fail please check and change the battery 3 If the remote control works but the Control Unit fails to send SMS texts switch the power of Control Unit off and switch it on after one minute Test this system after another minute or check the settings are correct and the GSM Signals are strong enough King Pigeon Hi Tech Co Ltd Page J of 20 Ver 1 2 File No 35260011 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com lf the Control Unit can run and sensors work but cannot send SMS texts please change SIM Card to check it lf the problem cannot be solved please contact the distributor or manufacturer 13 Warranty 1 2 This system is warranted to be free of defects in material and workmanship for one year from the date of purchase This warranty does not extend to any defect malfunction or failure caused by abuse or m
13. oesn t makes Di sound means the learning failure please try again King Pigeon Hi Tech Co Ltd Page of 20 Ver 1 2 File No 35260011 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com Appendix Zone Appendix Zone Setting Table g Table Po meee ete tate ae EAEN Wireless Zone Activated zone 4 Wireless Zone Activated 1 1 0 1 zones Wireless Zone Activated 1 1 1 0 zone 7 Wireless Zone Activated 1 0 0 1 zone Wireless Zone Activated 0 1 0 1 1 All the Zone Names can be edited by user through SMS Commands 10 Technical specifications of Control Unit Rated Voltage 12VDC 1 5A Working temperature 100 O 600 Storage temperature 20 O 600 Relative humidity 10 90 No condensation Work frequency GSM900 1800Mhz King Pigeon Hi Tech Co Ltd Page of 20 Ver 1 2 File No 35260011 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com Communication protocol GSM PHASE 2 2 include data service Wireless sensor receiving frequency 433 0 5MHz Wired Zones 2 Wireless Zones 8 Related Voltage of the Output Relay 2A 250V AC Effective distance of wireless transmission 100 m Open area Battery Built in lithium ion battery 1000mAh_ 7 2V Standby time Approx 12hours depending on the network condition Net Weight 0 80Kg 11 Important information 1 Please read the User Manual carefully before you i
14. om below Open the back cover of the Wireless sensor carefully Locate the IC boards black jumpers labelled AO A7 and DO D3 The A0 A7 3X8 PIN connectors are the Wireless Address bits code area and the DO D3 are 3X4 PIN connectors are Wireless data bits code area Also you can see the H N and L letters besides the 3X8 PIN and 3X4 PIN connectors like below Connect L and N is means 0 and connect H and N is means 1 connect neither L and N nor H and N is means 2 According to below table select the Zone and set the 3X4 PIN Wireless data bits code area according to selected zone According to the wireless sensors in the Standard package set all wireless sensors Wireless Address bits the same Then install the cover carefully Turn off the sensors power before setting Trigger the wireless sensor and test the setting result If the wireless sensors do not work please check the jumpers again 10 You can set many sensors in the same zone After you restored the system to factory deflaut By press the Reset Button you should learn the wireless senors to the control units again The method is below Step 1 Power on the Control Units and waiting it registered successful Step 2 Press the Reset button in the backside of the control unit nearby the Simcard Solt the Busy LED will turn Red Color trigger any wireless sensor the Busy Led will flash and make Di Sound to confirm the operation If the control unit d
15. r any device or sensors that need 12VDC to work PING Output relay negative electrode King Pigeon Hi Tech Co Ltd Page of 20 Ver 1 2 File No 35260011 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com Relate Voltage 2A 250VAC Output relay positive electrode Relate Voltage 2A 250VAC GND Wired sensor input 1 e g Temperature sensor Wired sensor input 2 e g Photoelectric Beams Sensor The Output relay is similar the Power Switch you can use it to control the light gate DVR and other applications Its drived by 5VDC related voltage is 2A 250VAC lt 40W when you use high viotage applications please note the cables 5 Features 1 GSM Frequency Dual Band 900 1800MHz 2 Can armed disarmed by SMS or remote control 3 Automaticed send SMS Alert to the pre set cellphone when any sensor triggered 4 Equips with 2 Wired Zones NC NO is optional Zone Name is editable 5 Equips with 8 Wireless Zones Zone Name is editable 6 Supports 3 SMS Alert telephones and 5 Call alarm phone numbers 7 Equips with 1 relay output it like a switch use for driving DVR light gate or other electric appliances once the system triggered The relay output On or Off can be controlled by SMS or Telephone 8 The external power failure alert function 9 Supports wiretap through internal Mircophone 10 Can remote start Siren and arm Disarm the system by telephone 11 Can alert the

Download Pdf Manuals

image

Related Search

Related Contents

La détection de gaz à la portée de tous  GE Wayside Signals Data Sheet  télécharger le magazine Oct. 2013    User manual ver. 1.62  II-EVB-600 User Manual  Avaya ST2 User's Manual  La marque Charte Ambassadeur  NETTOYANT JANTES SANS ACIDE  Válvula Val-Matic® de Aire y Vacío de 1/2"  

Copyright © All rights reserved.
Failed to retrieve file