Home

Air King User Manual

image

Contents

1. ING OF BOTH THE CIRCULATOR AND CABLE COULD FAIL IF SUB ae JECTED TO ABUSE NEGLECT OR IMPROPER INSTALLATION 1 OPERATION 1 Plug in cord and select desired operating speed with pull cord 2 WARNING This fan should be used only in a clean dry environment Mounting of this product in any way other then specified in the instruction sheet will null CAUTION THE SECONDARY SUPPORT CABLE PROVIDED and void the manufacturer s warranty SHOULD BE USED ANYTIME THE CIRCULATOR IS MOUNTED OVERHEAD FOR ADDITIONAL SAFETY MAINTENANCE Figure 2 SECON DARY SUPPORT CABLE WARNING ALWAYS UNPLUG THE CORD BEFORE SERVICING Loop one end of Cable around the Large Diameter Wires of both the CLEANING Use a soft cloth and a mild soap solution such as liquid dish Front and Rear Circulator Guard Figure 4 washing detergent 2 Attach a Cable Clamp with the U on the tail side of the loop leaving CAUTION DO NOT USE GASOLINE BENZINE THINNER HARSH a tail approximately 1 to 2 inches Tighten Clamp Nuts Make sure no CLEANERS ETC WHICH WILL DAMAGE THE FAN part of the Cable interferes with the Blade Figure 4 Dry all parts with a soft cloth completely before reconnecting to power supply 3 Wrap the other end of the Cable around a secure building joist truss STORAGE When not in use keep unit in a clean dry place l Beam or other support near the Fan Do not attach
2. doors Rain may create an electrical hazard 8 Completely reassemble fan according to instructions before reconnecting to power supply WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICE WARNING THIS PLUG IS A SAFETY FEATURE TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK AND PERSONAL INJURY DO NOT REMOVE REPLACE REPAIR OR TAMPER WITHTHE ORIGINALLY SUPPLIED PLUG IF THE FAN DOES NOT FUNCTION PROPERLY IT MAY BE DUE TO THE SAFETY DEVICE INCOR PORATED IN THIS PLUG RETURN TO AN AUTHORIZED SERVICE CENTER OR CALL 800 233 0268 MONDAY FRIDAY BETWEEN 8 00 A M AND 5 00 P M EST IF THE PLUG WARNING LABEL IS MISSING OR DAMAGED CALL THE TOLL FREE NUMBER FOR A REPLACEMENT LABEL Rev A 9 07 locations THIS FAN DOES NOT MEET THE REQUIRMENTS OF NEC ARTICLE 500 2002 ARNING This fan should be used only in a clean dry environment Mounting of this product in any way other then specified in the instruction sheet will null and void the manufacturer s warranty WARNING BECAUSE OF SIZE AND WEIGHT OF THIS FAN MAKE SURE ALL PARTS ARE COMPLETELY ASSEMBLED ACCORDINGTO INSTRUCTIONS FAILURETO DO SO COULD RESULT IN FAN COMING APART DURING OPERATION AND OR PERSONAL INJURY BEAM MOUNT INSTALLATION Locate the L shaped pipe to the desired location on the I Beam flange Install the 5 16 x 2 U Bolt over the pipe and through the clamping plate holes The flat part of t
3. ATION ANY IMPLIED WARRANTY OF MERCHANTABILITY LAST ONE YEAR FROMTHE DATE OF ORIGINAL PURCHASE OR UNTIL THE ORIGINAL PURCHASER OF THE PRODUCT SELLS OR TRANSFERS THE PRODUCT WHICHEVER FIRST OCCURS AND IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE I INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER OR Il REPLACMENT OR REPAIR OF ANY HOUSE FUSES CIRCUIT BREAKERS OR RECEPTACLES NOTWITHSTANDING ANYTHING TO THE CONTRARY IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY EXCEED THE PURCHASE PRICE OF THE PRODUCT AND ANY SUCH LIABILITY SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD Some states and provinces do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so these exclusions or limitations may not apply to you This warranty gives you specific legal rights You may also have other rights which vary from state to state and province to province Proof of purchase is required before a warranty claim will be accepted Po NY A BY AYO CUSTOMER SERVICE Toll Free 800 233 0268 Email producthelp laskoproducts com Our Customer Service team is available to assist you with product questions service center locations and replacement parts They can be reached Monday through Friday 8am 5pm Eastern Please have you
4. OPERATING INSTRUCTIONS amp PARTS MANUAL 20 I BEAM MOUNT FAN 20 50 8 cm MODEL 9520 Ventilation Products READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE INSTALL OPERATE OR MAINTAIN THE PRODUCT DESCRIBED PROTECT YOUR SELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND OR PROPERTY DAMAGE RETAIN INSTRUCTIONS FOR FUTURE REFERENCE 9 This Fan is not suitable for use in hazardous locations Please refer to National Electric Code NEC Article 500 or applicable state or local codes or standards relating to electrical requirements for Hazardous DESCRIPTION The Air King 20 50 8 cm l Beam mount fan features 3 speed pull cord operation and a 3 paddle fan blade This fan has a permanently lubricated motor with a 9 ft 2 74 m 18 3 cord set and is constructed of sturdy powder coated steel SPECIFICATIONS MO tol ssciscvsscsseesarseesecssevessazeszanes 120 V 50 60 Hz Blade diameter 20 50 8 cm Model 9520 Speeds aspinius 3 COMMU iisa eeestis Pull Cord Air flow distribution 0 360 APPIOVAIS irissen UL ETL Listed Close mesh fan guard meets OSHA requirements 1 Make certain that the power source conforms to the electrical requirements of the fan 2 The power cord is equipped with a three prong grounded plug that must be inserted into a matching receptacle Under no circumstance
5. cable to l Beam MOTOR IS PERMANENTLY LUBRICATED mount pipe Figure 3 Take up all excess slack in the Cable Figure 3 Figure 4 PART BAG Large Guard Description Qty Wires 5 16 x 2 U Bolt _ lt Clamp Plate Secondary Sf 5 16 13 Nut Support j 5 16 Lock Washer 5 16 Flat Washer Rubber Spacer Grill Knob Set Screw 1 4 20 Secondary Support Kit Allen Key LIMITED WARRANTY WHAT THIS WARRANTY COVERS This product is warranted against defects in workmanship and or materials HOW LONG THIS WARRANTY LASTS This warranty extends only to the original purchaser of the product and lasts for one 1 year from the date of original purchase or until the original purchaser of the product sells or transfers the product whichever first occurs WHAT AIR KING WILL DO During the warranty period Air King will at its sole option repair or replace any part or parts that prove to be defective or replace the whole product with the same or comparable model WHAT THIS WARRANTY DOES NOT COVER This warranty does not apply if the product was damaged or failed because of accident improper handling or operation shipping damage abuse misuse unauthorized repairs made or attempted This warranty does not cover shipping costs for the return of products to Air King for repair or replacement Air King will pay return shipping charges from Air King following warranty repairs or replacement ANY AND ALL WARRANTIES EXPRESSED OR IMPLIED INCLUDING WITHOUT LIMIT
6. he clamping plate fits on the l Beam flange and the end with the slight bend goes against the pipe Install flat washer lock washer and nuts Finger tighten the nuts on the U Bolt Figure 1 2 Slide the clamping plate onto I Beam flange until U Bolts contact flange 3 Adjust L shaped pipe so forward clamp plate is as close to the label at the bend as possible 4 Tighten nuts on bolt so pipe does not move 5 Screw on the adapter mount as far as it will go on to the L shaped pipe Tighten set screw in pipe coupling with provided allen key 6 Align Yoke with grill mounting threads Loosely attach one Grill Knob and one Rubber Spacer to the Head Assembly Attach the other Grill Knob and Rubber Spacer to the Head Assembly and FIRMLY tighten Return to the first Grill Knob and FIRMLY tighten Figure 2 5 16 Nut 5 16 Lock Washer Tighten Clamp Plate Here 5 16 Flat Washer 1 4 Set Screw gan Yoke ir WWI S Tighten Bolt EE Z Figure 1 5084037 MODEL 9520 CAUTION USE ONLY THE MOUNTING HARDWARE WHICH IS RECOMMENDED FOR USE ON THIS FAN Rubber 4 Attach the remaining Cable Clamp as indicated in Step 2 The excess Spacer tail should be trimmed to extend 1 to 2 inches past the Clamp Th 5 Check the Assembly to assure the Blade is free of all obstructions Yoke CAUTION USE OF THE SECONDARY SUPPORT CABLE DOES NOT Mi i GUARANTEE PROTECTION AGAINST INJURY OF PERSONS MOUNT
7. r model number available as well as the type and style located on the underside of your product Please do not return product to place of purchase Customer Service Dept 820 Lincoln Ave West Chester PA 19380 Please do not send product to this location www laskoproducts com PARTS FOR DISCONTINUED OBSOLETE AND CERTAIN OTHER PRODUCTS MAY NOT BE AVAILABLE DUE TO SAFETY REASONS MANY ELECTRONIC COMPONENTS AND MOST HEATER COMPONENTS ARE NOT AVAILABLE TO CONSUMERS FOR INSTALLATION OR REPLACEMENT Rev A 9 07 2 5084037
8. s should the grounding prong be cut off the plug Where a two prong wall receptacle is encountered it must be replaced with a properly grounded three prong receptacle installed in accordance with the National Electrical Code NEC and all applicable local codes and ordinances This work must be done only by a qualified electrician using copper wire only WARNING USE OF ATHREE PRONG TO TWO PRONG ADAPTER IS NOT RECOMMENDED IMPROPER CONNECTION MAY CREATE THE RISK OF ELECTRICAL SHOCK USE OF SUCH ADAPTERS IS NOT PERMITTED IN CANADA 3 Where possible avoid the use of extension cords If they must be used minimize the risk of overheating by ensuring that they are UL listed and of the proper gauge and length Never use a single extension cord to operate more than one fan 4 Do not insert fingers or foreign objects into the fan Do not block or tamper with the fan in any manner while it is in operation Do not touch the fan while in operation or just after it has been turned off as some parts may be hot enough to cause injury 5 Unplug power cord before installing or servicing the fan AARNING DO NOT DEPEND UPON THE ON OFF SWITCH AS THE SOLE MEANS OF DISCONNECTING POWER WHEN INSTALLING OR SERVICING THE FAN ALWAYS UNPLUG THE POWER CORD 6 This fan is intended for general use ONLY It must NOT be used in potentially dangerous locations such as flammable explosive chemical laden or wet atmospheres 7 DO NOT mount fan near windows or bay

Download Pdf Manuals

image

Related Search

Related Contents

- XeVision  Atomic Accessories DSA.95 game console accessory  【チラシ】仮想化を成功に導くHP + VMware  Samsung SM-B312EH Manuel de l'utilisateur  Untitled - Qafqaz University  DENSÍMETROS NUCLEARES Roadreader™ Plus de TROXLER  User Manual AO 6008 rev O  平成ー 9年度医療機器自主回収一覧 (クラス五)  Sanus Systems VST15  ToughPAR V12 Manual  