1.  can be connected to the water draining hole located at  the top of the water collection tank to directly drain out the water drops  After completing the draining  push  up the upper red button to remove the hose   refer to figure 5     Figure 4 Figure 5       The LOW FOG 3000 FT is equipped with a pump temperature sensor  When the fog fluid is used up in the  tank  the pump will stop running due to the rising of the temperature  When the machine temperature drops  down  the pump will resume to run  Please check to see if the fog fluid is sufficient in the fluid tank    A black square metal mesh is located at the back of the machine  This is the air inlet of the fan  Please do not  block the inlet and clean it routinely to keep the cleanness     If the fog volume is too low  the machine generates noise during operation or the fog cannot be smoothly  sprayed  please turn off the power immediately and check if the fog fluid is sufficient  whether the external  fuse  controller connection or power supply has any problem  If none of the above shows any problem  insert  the power plug again  If the machine still cannot normally operate  please check whether the hose connect   ing to the fog fluid tank is blocked  and if any fluid is flowing  If the cause cannot be identified  please do not  allow the machine to operate to avoid damage  Turn offthe machine immediately and let it cool down  Please  contact an Robe dealer or a designated service center Do not disassemble the machine 
2.  for a longer period  clean it and drain all fog fluid from the tank  Disconnect and  store the fog pipe and power cord  Store the machine and all parts into the parts tank located at front of the  machine  Warm up the machine once a month  to protect it from moisture    Store the machine cool and dry     12  Technical specifications    Power  230 240V AC  50 60 Hz    or 100 120 V AC  50 60 Hz optionally   Power consuption  750 W    120V   600W    230V   Refrigerant  R 404A  1 75 Ib   Rated current  6 7 A    120V  3 2 A    230V   Start current  61A  120V  21AQ 230V   Capacity  3200 BTU  hr    120V  2745 BTU  hr    230V    Compressor   s breaker  15 A  250 V    120V  10 A  250 V    230V  Fog machine s breaker  15 A 250V   Heater  1450 W  120V  2500 W    230V   First heat Up time  24 min    120V  12 min    230V     Tank capacity  10 Liters   Output  12 000 cu ft Min   340m  min    Liquid used  Premium Fog  Performance Fog  Fluid cons  rate  11 min Liter  high output    DMX channels  1   DMX connection  3 pin and 5 pin XLR male female    Dimensions  mm   L 780 x W 608 x H 688 mm    Weight  empty tank   120 kg   Remote included   LCD Timer Panel Controller  2 m cable  Accessory included  3m fog conducting hose   Additional information  Self contained unit    no CO  dry ice required    Floor mount installations  4 wheels     November 13  2012  Specifications are subject to change without specification    
3. LOW FOG 3000 FT                 USER MANUAL F Tse ries     EEEE    Version  1 1                ROBE Lighting s r o  e Czech Republice www robe cz Mas       LOW FOG 3000 FT       Table of contents      Introduction     Safety instructions     Unpacking 8 Inspection  Setup     Operation     LCD Timer panel controller    Important notes     DMX 512 settings   9  Operation notice  10 Configuration the pump power for local AC power   11  Maintenace of the machine  12  Technical specifications    ONOORWD      O  O    O    NOOUTOUOTRR R    1  Introduction    Thank you for choosing an ROBE LOW FOG 3000 FT  The machine has some terrific new features on top of  the fog cooling provided by the DNG 100 originally  The fog generator is integrated into this new machine to  make sure the machine will not take too much space in order to maximize the usage of the entire stage     Different from others  Robe s fog machines do not use carbon dioxide  and do not pollute environment and  and are not harmful for human health  The DNG 200 is a great machine that offers low fog special effects as  well as environmental friendly features  a true green machine    Please follow these operation  safety and maintenance instructions to ensure a long and safe life for your fog  machine     2  Safety instructions    Risk of electric shock   Disconnect the appliance from the electric supply before removing the cover     Keep this device dry    For indoor use only  Not designed for outdoor use    The ideal op
4. by yourself     After using the LOW FOG 3000 FT for a long time  there may be residue on the floor which could be a pos   sible cause of danger  Please note the material of the floor and pay special attention to the safety of persons  walking on it     7    The LOW FOG 3000 FT does not use dry ice  It is very environmental friendly and safe  However  the output  fog is easily to be blown away by wind     8  DMX 512 settings    The LOW FOG 3000 FT is equipped with a DMX512 system  For connecting a DMX controller  3 pin   and 5 pin male female XLR connections are provided at the back of the machine  The machine uses one control  channel for adjusting the output volume  The channel has a DMX value range of O to 255  After connecting  a DMX controller  timer functions such as output duration and interval can be programmed using the DMX  controller or the DMX control software  The machine cannot be controlled via the D 20 control anymore  By  using the DMX protocol  fog machines  lighting effects  and other special effects machines can be intercon   nected and easily controlled     192   255   high volume  60   output     127   191   medium volume  52   output   32   126   low volume  35   output     0   31   off  no fog output     Between the values O to 31 the machine does not have sufficient output volume and is off   Between the values 31 to 126 the machine has a minimal output volume of 35    Between the values 127 to 191 the machine has a medium output volume of 52     Betwe
5. chine will automatically emit fog  The time intervals  duration  and fog volume depend  on the corresponding menu settings  Press the button TIMER  to activate the timer mode  The display indicates  the set time interval  The unit counts down to O seconds and emits fog  To deactivate the timer mode  press  the buttonTIMER again     Continuous operation   Press the button VOLUME  to activate continuous fog output  The display indicates the value that was set in  menu item  Volume Out    i e  Nonstop Burst  High  Medium or Low To stop the fog output  press the button  VOLUME once again     Manual operation   For immediate fog output at the maximum volume of fog  keep the button MANUAL pressed  The display  indicates  Manual Output     As soon as you release the button  the fog output will stop  The manual opera   tion will take priority over the continuous operation and the timer operation  Even if one of these operating  modes is activated  the fog machine will always emit the maximum volume of fog when the button MANUAL  is pressed     7  Important notes    A water collection tray is equipped at the rear of DNG 200  When the compressor is running for condensed  fog  some water drops will flow into the tray  Please check the water level of the tray routinely and drain it on  time to prevent overflow   refer to figure 4      If the machine is to be used for a long time or the water drops cannot be checked momentarily  the water  collection tray can be removed and a 6 mm PU hose
6. en the values 191 to 255 the machine has a maximum output volume of 60       9  Operation notice    After operation  please wait 15 minutes before turning off the machine    Please do not turn the power on and off continuously  There must be at least a one minute interval between  each power on and off    Operate the machine in a well ventilated area    Do not position two or more DNG 200 machines side by side to prevent poor hot air ventilation    Do not operate the machine under direct sunlight    It is strongly suggested not to have the machine produce continuous fog output over 20 minutes  Overtime  usage might reduce the efficiency and lifespan of the compressor     10 Configuration the pump power for local AC power     The device pump is factory configured for 230V 50Hz If your AC power is different the pump power can be  configured for the local voltage using the follow procedure     1  Press the CX    button and turn on the machine at the same time        5  The current voltage will appear on the display  Use and buttons to choose the one you need   6  Presss Enter Key after chosen the voltage    7  The main screen will appear on the display    11  Maintenace of the machine    DANGER    Disconnect from the mains before starting any maintenance work     Cleaning your fog machine regularly will help reduce costly replacement and repair charges    Do not allow the fog fluid to become contaminated  The cap should be on the tank at all times    Prior to storing the machine
7. erating temperature is between 10   and 30   Celsius    Two sets of professional power cords are used by this machine  It is important to confirm the electrical voltage  before plugging the power cord into the power outlet  Use a threeplug grounded power outlet    If the machine is moved or transported  it shall be stationed for one hour to allow the coolant in the cooler to  stabilize before using it again    If the machine is moved horizontally  please station it for 5 minutes before starting the operation again   Please unplug the power cord or turn off the machine if it is not in use    This machine is not water proof  If moisture  water  or fog fluid gets inside the housing  immediately unplug  the unit and clean it  If the machine cannot be cleaned  please contact a service technician or your Robe  distributor before using it again    No user serviceable parts inside  Refer to your Robe dealer or other qualified service personnel    For adult use only  The fog machine must be installed out of the reach of children  Never leave the unit running  unattended    Operate the machine in a well ventilated area  Never cover the unit s vents  The fog machine is best installed  1 meter away from all objects    It is important to place the machine on a flat surface instead of a surface with slope to revent any moving of  the machine    If your Robe LOW FOG 3000 FT fog generator fails to work properly  please turn off the   power for five minutes and turn it on again  If the proble
8. eration  Press the button FUNCTION until the display indicates  Duration Set     Use the buttons UP and DOWN to  adjust the duration of the fog outputs in timer mode within the range of 10 and 100 seconds    Setting the fog output volume  Press the button FUNCTION until the display indicates    Volume Out     Use the buttons UP and DOWN to select  one of four default settings for the fog output volume   e Nonstop Burst The machine will continuously produce low fog  The output volume is automatically  adjusted by the machine based on the operating temperature   e High Volume    about 60 output volume  e Medium Volume    about 52 output volume  e Low Volume    about 35 output volume    Output volume Output duration Pause between fog outputs  Nonstop burst Continuous output         High volume  Continuous output              When set to  Nonstop Burst    or  Low Volume     the machine will continuously produce low fog   However  the setting    Nonstop Burst    will produce the higher output volume      Please suspend the operation for 5 minutes before switching from the setting    Nonstop Burst    to  the setting    High Volume    or    Medium Volume         Setting the DMX512 address   Press the button FUNCTION until the display indicates    DMX 512 Add     Use the buttons UP and DOWN  to  set the machine to the same address as on your DMX controller  Please refer to the chapter DMX512 settings  for more information on DMX operation    Timer operation   In the time mode  the ma
9. hus the air in the  liquid pipe is drained out  Once the fog comes out smoothly  the LCD Timer panel controller can be set  If the  machine is used infrequently  please follow this procedure every time it is used to drain out the air     The heater average temperature of the LOW FOG 3000 FT is 220  C     6  LCD Timer panel controller    The LCD Timer panel controller is equipped with a 2 meter line  a 5 pin XLR connector  and an LCD screen  displaying all operation statuses of the fog machine  The interface allows the operator to customize fog ma   chine functions by adjusting the fogging duration  interval  and volume as well as the DMX address  There  are six buttons on the control board  All current operating parameters are automatically stored in non volatile  memory  allowing the machine to be powered down without losing function settings     Configuration of the buttons   1    Function  button    Interval Set   Duration Set   Volume Out   Nonstop Burst   High Volume   Medium Volume   Low Volume   DMX 512 Add    2  A Up Down button    3  Timer  button          4   6    Volume  button                      5     84   Manual button       Menu settings with the button FUNCTION   Setting time intervals for timer operation  Press the button FUNCTION until the display indicates    Interval Set     Use the buttons UP and DOWN to adjust  the intervals between the individual fog outputs in timer mode within the range of 10 and 300 seconds   Setting the output duration for timer op
10. m still exists  contact your Robe distributor for servi   ce    Always allow the machine to cool down before attempting to clean or service it    Please use Robe FLR Light Fog Fluid only  Please do not fill in any other fluid into the tank to ensure the  quality of the fog and the life of the machine     Pay attention to all warning labels and instructions printed on the exterior  of your LOW FOG 3000 FT    3  Unpacking  amp  Inspection    Open the shipping carton and verify that all equipment necessary to operate the system has arrived intact   The shipping carton should contain the following items      LOW FOG 3000 FT machine     LCD Timer Panel controller  preinstalled in the machine      Two power cords for connecting to Neutrik PowerCon connectors      3m fog conducting hose     User s manual  item 3 5 placed in the storage box on the top of the machine      Water collection tray  preinstalled in the machine      3m PU tube  6mm      4  Setup    1  The wheels at the bottom of the DNG 200 help to move the machine  wheel fixing mechanisms are located  at the diagonal line  Position the machine at a spot  press down the fixing mechanism to prevent it from moving   To move the machine  press the opposite side of the fixing mechanism to release it  Please note that the         machine is not allowed to place on a slope due to its big size   refer to figure 1          Figure 1      2  Please aim the key on the PowerCon terminal of the power cord to the slot ofthe connector on 
11. the machine   plug it in and turn it about 10   clockwise until the power cord is completely fixed  The upper power cord is for  the fog generator and the bottom one is for the compressor   refer to figure 2 and 3        Figure 2 Figures    3  Connect the machine with the black fog conducting hose  it is a three meter pipe  The length of the pipe  can be adjusted to fit the actual need   refer to figure 4  Fill Robe Premium fog fluid to the tank  tighten the  tank cap     5  Operation    1  Connect the power cord to a grounded outlet  press down two sets of power switches located at the back  side of the machine  Please press the power switch of the compressor below first and then the power switch  of the fog machine  The warm up process is started  The LCD screen on the D 20 controller will show    War   ming up       2  While the unit is warming up  fog output will not be possible yet  Please wait till the LCD screen shows     ReadyTo Fog       3  Program the necessary menu settings with the control panel of the LCD Timer panel controller  refer to  chapter LCD Timer panel controller     The LOW FOG 3000 FT is equipped with a DMX512 system  3 pin and 5 pin DMX connectors each are located  at the back panel of the machine for optional use   refer to chapter DMX512 settings     4  When operating the machine for the first time  wait until the controllers LCD screen shows    Ready To  Fog     Actuate the button Manual for a few seconds to initiate fog output from the machine  T
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Navman 4100 GPS Receiver User Manual  iStarUSA D-400-6 computer case  (施行規則、運用要領併記)(PDF  MAVERICK-II Installation and Hardware Reference Manual  Owner`s Manual - Power Acoustik  PYLE Audio PLPSE9WL User's Manual  - LTI Motion  OM, Hanseatic, SL546 E, SL546 ED, 966855701  "取扱説明書"  公民館だより平成27年 2月号(PDF 467KB)    Copyright © All rights reserved. 