Home

User Manual English - Cal

image

Contents

1. 2 ADVANCE SETTING hx AE MODE AUTO SHUTTER N A IRIS N A BRIGHT N A WB MODE AUTO R GAIN N A B GAIN HI RESOLUTION OFF BACK EXIT J Camera Setting In the camera setting menu you can access camera module related settings Please note that depending on module s capability some functions may not be available Please contact your local sales representative for detailed information ZOOM SPEED Defines the speed whith which zoom functions are performed DIGITAL ZOOM Activates or deactivates the camera module s digital zoom function BLC MODE Selects the Back Light Compensation mode which improves the image when an object has strong back light SLOW SHUTTER Activates the Slow Shutter function of the camera which provides a higher light sensibility in low lit environments IR CUT FILTER Enables the removal of Infrared Cutter Filter IRC also known as DAY NIGHT mode Enabling the IRC the camera turns into Black White mode and has higher sensibility to low light situations or turns on the IR light depending on the light condition Selectable between On Off or Auto Only available on camera modules with IRC function LINE SYNC Enables and disables Line Synchronization Advanced Setting Under the advanced setting you can make improvements tothe image quality depending on different environmental conditions AE MODE Auto Exposure mode Depends on the light condition in
2. Patterns Patterns record the user s movement while performing PTZ operations and stores themas a track The Speed Dome can record up to 4 tracks with max 180 sec each PATTERN NUMBER Supports up to 4 patterns PROGRAM PATTERN Starts recording the pattern when selected You can perfom PTZ movements for recording not exceeding 180 sec Press IRIS OPEN to save the track RUN PATTERN Starts the current pattern CLEAR PATTERN Deletes the current pattern EDIT PATTERN LABEL Sets the name for the current pattern Tour Tour is an auto operation running through selected preset points with definable pause time Atour can store up to 24 preset points TOUR NUMBER Supports up to 4 tours TOUR PRESETS P0 Move the joystick up and down to select the preset points by number and save the settings by going to the left end of the line If a selected point has the value 0 all the following preset points will be ignored SPEED 5 Speed of the dome between 2 points TOUR DWELL TM Pause duration after reaching a preset point Duration can be set between 00 60 s RUN TOUR Starts the tour and exits the OSD Menu Some products may not be available in your country please contact our distributor for more details ZONES ZONE NUMBER 1 SET LEFT LIMIT SET RIGHT LIMIT CLEAR ZONE EDIT ZONE LABEL BACK EXIT WINDOW BLANKING WINDOW NUMBER 01 EDIT WINDOW ENABLE WINDOW OFF C
3. 1 High Speed Dome Camera Series User Manual English v2 33 WARNING CONTENTS TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS PRODUCT TO RAIN 1 Precaution 1 OR MOISTURE DO NOT INSERT ANY METALLIC OBJECTS THROUGH THE VENTILATION GRILLS OR eg a ee ieee OTHER OPENINGS ON THE EQUIPMENT 2 2 3 E a 3 A NNSA WOM 4 CAUTION 1 Operating th 5 10 RISK OF ELECTRIC SHOCK voltage constituting a risk of electric 6 0 11 DONOT OPEN 12 System 19 CAUTION REDUCE THE RISK Motion Clear 14 OF ELECTRIC SHOCK DO NOT j USER SERVICEABLE PARTS importantopetating SERVICE PERSONNEL SHOULD instructions in the literature Platterns 2 2 17 Zones and Privacy 18 Alarm 19 7 Protocol Setting 20 FCC COMPLIANCE STATEMENT gt IP PO
4. Make sure that the enviroment of installation meets the requirements of the appliance such as holding the weight and providing enough space for bracket and power supply 4 Some products may not be available in your country please contact our distributor for more details 4 INSTALLATION 4 INSTALLATION Connector description Using optional accessories The speed dome camera series can be connected to various optional accessories through the standard connector types which simplifiy the cable handling and avoid possible mistakes All accessories are tested for max Compatibility and best performance Outdoor power adaptor box 3 Axis keyboard RED 24 230V to AC 24 controller BLACK 24 Power power supp y AC 24 Power supply Power input GN A Telemetric control camera setup YELLOW RS485 GREEN Rs485 RS 485 t RS 485 Connector To keyboard or DVR devices for telemetric control RJ 11 Indoor power adaptor 21 High Res AC 230V to AC 24V security monitor Inner Conn Signal 24 Power supply gt 40 Outer Conn Ground 4 Video output Video Output to monitor or DVR BNC Professional Real time 16 Channel DVR AC 230V IAR Power input J RED Alarminput 1 1 Alarm input 2 YELLOW
5. ALARMS RESUME OFF RESET DELAY 020 ALARM CONTACT ALARM SETTING BACK EXIT ALARM SETTING ALARM NUMBER 001 ALARMACTION TOUR ACTIVATEAUX 1 BACK EXIT cor Alarms RESUME Continues the previous function of the camera before the alarm was activated RESET DELAY How long the camera stays in Alarm mode ALARM CONTACT Setting between N C normal Close or N O normal Open ALARM NUMBER Ranging from 1 7 ALARM ACTION Setting for PRESET SCAN TOUR PAT 1 4 or NONE if the camera s alarm function is activated ACTIVATE AUX Setting Alarm Output when alarm is activated Select between AUX1 AUX2 not connected or BOTH Alarm Connection on Backboard 1 95 3 2 1 GND ALARMAS Alarm input 1to 7 Common port gt Alarm output 1 gt Alarm output 2 7 PROTOCOL SETTING a Protocol Setting This procedure is needed if a connection of the telemetric control with the keyboard device is desired You need to setup the dome address and protocol settings i a a ia The spe
6. SI FI SI Fe SI aI OI AI OI I SO RIO ay aa j Sy SHI LO oe Kee Kea Kean Kee Cae Ka Kae Fae Ca Fae Fae Fae 1 Ca Kae Fae Fa Cae Fae Fae Fae Ca Fa eae Kea Kea Kee Kea Kean Fae Cae Cee Fee Fae Kea Ca Ca Kee Fae Fae Ce Fa Fa Fae Ca Co Fo wa IN OO SILO Some products may not be available your country please contact our distributor for more details Gam bami kami bami bami I I I I I I I 4 4 4 4 4 4 4 4 4 4 4 4 4 4 7 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 1 Sy SOCIOL OOOO CO Ol OY bamn 4 4 El oa a A Jo So S A A A I Slo oo oo A SIN 4 4 IOIO M ke em 4 4 1 21 a OI Ol Re OI RI OI RI OI RI OI RI COI RI OI RI olm 4 72 an a 2 24 r lt gt 2 4 4 04 1 1 2 OI IY 4 4 4 4 4 4 4 4 4 Some products may not be ava
7. Alarm input 3 GREEN Alarm input 4 BLACK RS485 cable GRAY telemetric control of the appliance uses RS485 serial communication with duplex transmission technology Alarm I O WHITE Alarm output N O Depending on the cable type and baud rate the transmission distance could vary The BLUE Alarm output N C following table shows max distances based on cable with 0 56mm 24AWG twisted pair I O interface to additional alarm Baud Rate Due the environmental interferences such as eletromagnetic and induction fields or number of sensor or control devices 2400 bps 1700m connected appliance on the RS485 bus the 4800 bps 1100 transmission range may decrease 9600 bps 19200 bps 6 Some products may not be available in your country please contact our distributor for more details Some products may not be available in your country please contact our distributor for more details 4 INSTALLATION RS485 Termination Devices using RS485 control are usually connected in daisy chain which reqiuers termination with 120Q resistor on both ends The following graphic illustrates the connection methods Please note that a daisy chain connection type shall not exceed 7 meters RS 485 0 1200 1200 485 sister Resistor Device 1 Device 2 Device 3 The speed dome series provide an integrated termination switch It should be turned ON on the dome servin
8. 000 Sec 1 3 to 1 10 000 Sec Iris Control Auto Manua Auto Slow Shutter Gain Control Auto Manual 3 to 28 dB 2 dB steps 16steps Video Output VBS 1 0Vp p Sync Negative Y C Output S N Ratio More than 50 dB Pan Speed 0 4 300 per Sec Tilt Speed 0 4 150 per Sec Pan Range 360 Tilt Range 0 90 Communication RS485 multiple protocol coax Preset Positions 128 Presets Auto Pan Yes between 2 presets Tour Sequence 4 progr Tours with max 24 presets 4 Pattern up to 180s Alarm inputs 7 inputs 2 output Operating Temp Outdoor 40 C to 60 C Indoor 10 C to50 C Power 24V AC 24 60 VA outdoor 25 NOTES 26 Some products may not be available in your country please contact our distributor for more details Some products may not be available in your country please contact our distributor for more details
9. Instruction and 1 piece base plate operation manual 1 piece 1 piece Outdoor 7 Outdoor housing 1 piece with sun shield and cover 1 piece WARNING The transparent cover part is sensitive and must be handled with care Do not touch or rub the surface in any way with the protection foil Inproper cleaning methods will cause permanent scratches on the cover and cause unclear image or focusing error of the camera For cleaning the cover replace the original cover with the spare cover then wash it by immersing it into warm water containing a non corrosive cleaning agent 5 7 Spare dome Instruction and cover operation manual 1 piece 1 piece Some products may not be available in your country please contact our distributor for more details 4 INSTALLATION Safety Instructions before starting Do not install and operate this appliance in a flammable or explosive environment Make sure that the installation is done according to the local electricity safety regulations of your country Before installation and maintenance make sure that the appliance is disconnected from the power source Do not use any power source other than 24V AC in order to prevent damages to the device Please refer to the section Precaution for more details Handle the device during the installation with care Droping the product or extreme vibration may cause irreparable dama
10. I COI COI COI CI CIC ICICI I I I 4 7 1 41 41 41 41 41 41 4 4 41 4 41 41 4 4 41 4 41 41 4 4 4 41 41 41 41 4 4 41 41 4 4 1 1 kaad kaad 2 hami hami bami hami basni bami hami bami kaad kaad kaad kaad hami hami hami hami bami hami i ka eea a II ka YI OI OI COI COI I RI a CI CI ee ee I I RI I COI COI ee eea a I eI I YI COI a k ba ba ed a hami bami ed 1 4 41 21 1 41 41 21 41 4 ee Qa DI RI OS GI OI Ra OI RI SI RI OJ GI OI a OJ Ra OJ RI OJ aI OI RI DI RI OJ RI OJ Re OI Re OI Reo fae H SH LOD LD J LD LED LED LED LED LED LD Kej Ke N Kea Kea 1 21 Cae Fae Fae Fa 3 3 3 3 4 3 3 3 4 4 4 SOLO Ol Ol Clo 4 4 4 4 4 Some products may not be available in your country please contact our distributor for more details SIDI OI OO FYI RI RI RI OI OI COI COI RI RI RI RI OI 1 1 4 4 41 41 COI CI CI 4 4 NI olo 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 ned baw SII
11. ING indicates the selection CAMERA SETTING FUNCTION SETTING UP DOWN Moving between current menu items WINDOW BLANKING gt Changing the value in sub items ALARM RIGHT Enter the selected menu item EXIT Confirm the value change and return to item selection LEFT Exit from sub menu For more inforamtion please refer to the illustration on the next page for the OSD Menu structure Symbols and indicator Cursor Sub item is selected use up down to change value This item has subitem s AUTO SCAN 1 PATTERN 1 MAIN MENU WINDOW BLANKING ALARMS gt FUNCTION SETTING CAMERA SETTING MOTTON SYSTEM SETTING 2 Some products not be available in your country please contact our distributor for more details Some products may not be available in your country please contact our distributor for more details 6 OSD System Setting SYSTEM SETTING EDIT DOME LABEL INITIAL INFO DISPLAY SETUP MOTION CLEAR PASSWORD SETUP BACK EXIT EDIT DOME LABEL INITIAL INFO FIRMWARE V2 33 PROTOCOL FACTORY DOME ADDRESS 001 COMM 4800 8 1 BACK EXIT DISPLAY SETUP DOME LABEL OFF XX PRESET LABEL OFF ZOOM LABEL ON ZONE LABEL OFF DIRECTION LABEL ON TEMPRATURE LABEL OFF BACK EXIT A System Setting In the system setting menu you can modify operation and display settings such a
12. LEAR WINDOW BACK EXIT Zones You can define the zones in the whole PT range up to 8 zones When the display setting Zone Label is activated its label will be displayed on the screen The defined ranges of the zones should not be overlapping ZONE NUMBER Supports up to 8 zones SET LEFT LIMIT Left boarder of the current zone SET RIGHT LIMIT Right boarder of the current zone CLEAR ZONE Delet the current zone EDIT ZONE LABEL Changes the label name of the current zone Privacy Mask Window Blanking Privacy Mask is used to protect the privacy area that should not be displayed once the camera is pointed onit such as lavatory areas or the operation desk of an machine This might be mandatory required by local law regulations The Speed Dome supports up to 24 private masks depending on the installed camera module please contact your local sales representative for more information Hitachi camera modules 8 masking areas Sony Camera modules upto 24 masking areas except the 45 series provides only 8 LG CNB Camera modules no masking function WINDOW NUMBER Mask number EDIT WINDOW Edit position of the mask using the keyboard s joystick Presse IRIS OPEN to save ENABLE WINDOW Shows the mask on the screen 18 CLEAR WINDOW Deletes the mask Some products may not be available in your country please contact our distributor for more details 6 OSD Alarm Setting
13. TS CONSE 8 Address 1 21 FCC INFORMATION THIS EQUIPMENT HAS BEEN TESTED AND FOUND COMPLY WITH THE LIMITS FOR A CLASS DIGITAL DEVICE PURSUANT PART 15 OF THE FCC RULES THESE 9 25 LIMITS ARE DESIGHEND PROVIDE REASONABLE PROTECTION AGAINST HAMRFUL INTERFERENCE WHEN THE EQUIPMENT IS OPERATED IN A COMMERCIAL ENVIRONMENT THIS EQUIPMENT GENERATES USES AND CAN RADIATE RADIO FREQUENCY ENGERGY AND IF NOT INSTALLED AND USED IN ACCORDANCE WITH THE INSTRUCTION MANUAL MAY CAUSE HARMFUL INTERFERENCE TO RADIO COMMUNICATIONS OPERATION OF THIS EQUIPMENT INA RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPENSE CAUTION CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE COULD VOID THE USERS S AUTHORITY TO OPERATE THE EQUIPMENT CE COMPLIANCE STATEMENT WARNING THIS IS A CLASS A PRODUCT IN A DOMESTIC ENVIRONMENT THIS PRODUCT MAY CAUSE RADIO INTERFERENCE IN WHICH CASE THE USER MAY BE REQUIRED TO TAKE ADEQUATE MEASURES CAUTION BEFORE ATTEMPTING TO CONECT OR OPERATE THIS PRODUCT PLEASE READ THE LABEL ON THE BOTTOMAND USER S MANUAL CAREFULLY Technical specification are subjects to change without prior notification Manual
14. ed dome support multiple communication Some products may not be available in your country please contact our distributor for more details 8 Sw1 Sw2 protocols The settings can be changed by rearranging the DIP Switches on the rear side of the connector board as illustrated Please use the following table for detailed information SW 1 Represents the dome s address in binary form A oae iene the list on the next pages for B02 001100 DIAMOND 100100 205 protocol settting baud rate PUNDA t0110 DIP 1 to 6 Protocol settings KALATEL 010100 DIP 7 and 8 Baud rate settings LILIN 110100 Baudrate DIP 7 DIPS MOLYNX 001000 2400 bps 0 0 PANASONIC 1111000 4800 bps 1 0 PELCO D P 100000 9600 bps 0 1 5 000001 19200 bps 1 1 7 SAMSUNG 000100 SANTACHI 011000 UNIVISION 010001 VCL 110000 VICON 101000 AD 001100 Some products may not be available in your country please contact our distributor for more details yO OY OY OY 2 Oy OY OY OY SooSo yO Oy OY OY OY OY Kase Fam Kam Ka Fa Fa Fam Fa Fa Ka Fae Fae Kae Kae Kae ae Kae Fae Fa Fa DYE OOO OY OY COICO YOY COI COI COI OI CI COI OI COICO I COI C
15. efines the idle time prior to start a custom defined action park action The duration can vary from 1 to 240 minutes This function can bedisabled by setting the minute to 0 PARK ACTION The action which will be started after the idle time park time Selectable between Preset Scan Pattern Nr Tour or None POWER UP ACTION Action which starts after power up and self test Selectable between Auto Preset 1 Scan Pattern Nr Tour or None By selecting Auto the dome will resume the last action before power off FAN ENABLED Defines the temperature limit in C at which the internal cooling starts operating The standard limit is 40 C Clear You can clear setting s memory or reset the camera to factory default The follwing functions are supported Clear all zones Clear all presets Clear all patterns Clear all tours Clear all windows Factory defaults Warning The clear action cannot be undone Once an item is cleared it is impossible to retrieve the deleted setting Please make sure that the requested clear action is desired Password setup You can change password to access the OSD menu Default Password is 000000 14 Some products may not be available in your country please contact our distributor for more details CAMERA SETTING ZOOM SPEED HIGH DIGITAL ZOOM ON BLC MODE OFF SLOW SHUTTER ON IR CUT FILTER AUTO LINE SYNC OFF WDR MODE ON ADVANCE SETTING
16. et points memory 80 can be used for auto tour function 4 pattern tours 4 Scan tour Basic setup directly from keyboard Advanced setup through OSD On Screen Display menu Up to 24 privacy masking zones despends on camera module 7 alarm input amp 2 output 4 input amp 1 output pre wired Multi protocol through RS485 or coaxial cable Direction indicator on screen Aluminum alloy structure with high intensity and heat sinking High precision step motor for flicker less image during movement Camera Features High resolution with 530TVL and Wide Dynamic Auto Focus Auto lris Auto Brightness control Auto Balance IR cutter control Day Night mode switching Auto Slow Shutter Temperature monitoring and protection Alarm notification will be displayed once the inner temperature exceeds the limit In low temperature area the dome camera will only start after the operation temperature is reached Cooling fan activity is managed by the CPU extends the duration Other features Proportional pan for Focus Speed on different zoom factor Auto resuming user defined action such as tour pattern or scan after selectable idle time Power up Action activates tour or pattern by default depends on camera module type Some products may not be available in your country please contact our distributor for more details 3 PACKING LIST Indoor 227777 Core unit Indoor Roof Mount
17. g as the last device If a controller keyboard is used you also need to turn the termination ON on the keyboard Please refer to the keyboard s manual for details Termination on Termination Termination Termination on off off How toturn termination ON on the speed dome The termination switch is located on the rear side of the connection board For turning it ON open theconnector board How to open the connector board The connector board can be opened rear side by holding the metal clip and pull 1 Metal Clip holder Termination Jumper Press the metal Jumper 1 3 3 clip in and pull Term On ON ON OFF the board the Term Off default OFF ON ON Some products may not be available in your country please contact our distributor for more details outlined direction 4 INSTALLATION Star Connection The star form connection is a popular way to connect different devices It enables longer distance connection of different dome cameras It is recommended to use RS485 distributor to ensure the telemetric data transmission The advantage of star connection is that every channel can work independently and supports a cable length up to 1000 meters depending on the quality of the cable In case more dome cameras are installed the star connect
18. ges and void the warranty Do not install or operate the appliance close to high voltage devices or high voltage cables The safety distance should remain at least 50 m To archive best image quality it is recommanded to use underground cables shielded by steel tube Do not install the cable without any protection In a thunderstorm area or region with high inductive voltage such as high voltage transformer stations it is necessary to use additional lightning proof equipment and or lightning robs for protection For outdoor installations lightning protection and grounding of the device should be considered Please refer to the industrial saftey regulations of your country Grounding of the appliance should include anti interference fulfill the safety requirements Do not connect the ground with short circuited or other high voltage electric networks The resistance of down conductor should not exceed 4 Ohm and its thickness should be atleast 25mm This appliance has the lightning proof function which can prevent damages caused by high voltage pulse such as lightning strikes below 1500 V This appliance meets the 1 standard for water and dust proof Do not install the in door model for out door applications as the model is not designed withstanding permanent water exposure Make sure that the installation is protected from long time water drop or spatter which may damage the appliance
19. ilable in your country please contact our distributor for more details OY OY OY OY OY OY OY OIC Mm LO 4 LO rm LO FOO OY SSS LO LOD OPO Ke Ke Ke 3 1 1 coon hae try please contact our distributor for more details Some products may not be available your cou 9 SPECIFICATION OK SEM181 V48DN OK SEM26I V48DN OK SEMW36I V53DN OK SEM18S V48DN OK SEM26S V48DN OK SEMW36S V53DN OK SEM18HB V48DN OK SEM26HB V48DN OK SEMW36HB V53DN Day Night Day Night Day Night Signal Format PAL NTSC Scanning Progressive Image Sensor 1 4 inch Ex View CCD H Resolution 470 TVL 440K Pixels PAL 470 TVL 530 TVL High Resolution Viewing Angle 48 0 Wide end 54 2 Wide end 57 8 Wide end 2 8 Tele end 2 2 Tele end 1 7 Tele end Zoom 18x Opt 12x Digital 26x Opt 12x Digital 36x Opt 12x Digital Min Illumination 0 7 Lux 1 50 sec Color Day 0 7Lx 1 50 0 11 1 3 Day 2 0Lx 1 50 0 14Lx 1 3 Day 1 4Lx 1 50 0 1Lx 1 3 2 Night 0 01Lx 1 3 Night 0 7Lx 1 50 0 05Lx 1 3 Night 0 01Lx 1 3 Focus Auto Manual White Balance Auto Manual ATW Indoor Outdoor One Push WB Manual WB Wide Dynamic Function Sb36 Wb36 models Shutter Speed 1 to 1 10
20. ion can be extended with Termination additional RS485 distributors activated on every end RS485 cable up to 1000m per channel RS 485 Distributor Termination on Video Cable Coaxial cable with 750 impedance with copper conductor at the center and shielded with 95 copper The following table shows different cable types and their maximum length The values are for reference only Cable standard Max Dist Depending on the qualiy tof the cable RG 59 0 229m 750 ft environmental conditions the RG6 U 305m 1000 ft transmission distance might decrease RG11 U 457m 1500 ft If the cable length is more than 400 m it is recommended to use optional accessories such as video amlifiers or twisted pair video converters to amplify the video signal Up to 750m coaxial cable Video Amplifier optional High Res Monitor optional x Real time DVR Center Extend connection distance with optional video amplifier Up to 1200 twisted pair or cat 5 cable transmitter 5 optional He High Res Monitor optional x Real time DVR Center Extend connection distance with Twisted Pair optional video converter Some products may not be available in your country please contact our distributor for more details 4 INSTALLATION Installi
21. l information CAM TITLE 32 0 Temperature Current temperature inside the speed Optional bracket accessories dome C The speed dome can be equipped with various bracket accessories for indoor and Cam title User definable camera title ZONE 1 outdoor installation Please contact your distributor for further details Zone Current zone name A285 78 18X Pan deg Pan angle 0 359 Tilt deg Tilt angle 0 90 Zoom Factor Zoom factor Zoom factor N 5 22 2 Display of the information be activated L Tiltdegree i deactivated through the OSD menu Pplease refer to Pan degree Ceilling Wall mount and Corner Indoor wall Pole Outdoor the system setting for detais mount Power box mount mount mount Power box Zone description PTZ operation For the surveillance operation the dome be controlled from a keyboard device Multiplexer or DVR through RS485 interface Make sure that the cable is connected Indoor Indoor ceilling Extended wall 5 Wall and the settings baud rate Address ID and protocol of both keyboard and the dome embedded mount mount mounting mount are correctly configurated For further details on operating the PTZ please refer to the mount bracket user s manual of the keyboard 10 Some products may not be available in your country please contact our distributor for more details Some products may not be available in your country please contact our dist
22. may contain mistakes or print errors All trade marks mentioned belong to their respective owners Refer all work related to the installaion of this product to qualified service personnel or system installers Do not attemp to disassemble the appliance To prevent electric shock do not remove screws or cover There are no user serviceable parts inside Contact qualified service personnel for maintenance Handle the appliance with care Do not strike or shake as this may damage the appliance It should be protected against extreme pressure vibration and humidity during transportation and storage Damages caused by improper transportation voids the warranty Do not use strong or abrasive detergents when cleaning the appliance body and transparent cover Use adry cloth to clean the appliance when dirty When the dirt is hard to remove use a mild detergent and wipe gently Do not operate the apliance beyond its specified temperature humidity or power source ratings Do not use the dome camera in an extreme environment where high temperature or high humidity exists Use the indoor models within 10 C to 50 C 14 F to 122 F and a humidity below 90 The input power source is 24V AC 50 60 2 and requires 1000 Use the outdoor models within 20 C to 60 C 4 F to 140 F and a humidity below 90 The input power source is 24V AC 50 60 2 and requires 2500 Do not expose the indoor dome cameramodel to water or moisture do
23. ng the core unit to base board The core units and base boards are packed seperatly in order to protect them during transportation After unpacking and during the installation the core unit should be installed as follows Initial Screen After powering up the camera will enter into the self test mode and display the status screen see picture left It contains information about the model and current settings p 5 THE SPEED DOME Installing the core unit by inserting it into the housing Please note the position of tt the connector For releasing please press the lever lock to core and pull off the unit Connector Interface The intial screen will remain on until any user action is taken If the power up action is set the initial info wil vanish immediately FIRMWARE Model number V2 25 Current firmware version Protocol Control protocol which currently used Dome address Address ID of speed dome Please refer to the section Protocol setup for details Comm 9600 N 8 1 Current setting of the serial communication interface 9600 Baud rate Please refer to section Baud Rate setup for details N 8 1 No parity bit 8 bit length 1 stop bit This setting cannot be changed Power LED Once the base board is connected to power the power LED will light up Operation Screen Temperature The operation screen can display additiona
24. not try to operate it in wet areas Take immediate action when the indoor speed dome gets wet Turn off the power and refer servicing to qualified service personnel Moisture may damage the appliance and cause eletric shock Do not expose the camera lens directly to sunlight or other strong light sources This will cause permanent damage to the camera and voids the warranty Read this user s manual carefully before operating the appliance Make sure local electric safty standard are followed when using or installing the appliance Do not install the camera in other orientation as designed Do not bend or squeez the sturcture as this may damage the mechanic sturcture of the appliance and voids the warranty Do not touch the cover with bare hands or any objects These will scratch the surface and negatively affect the image qulaity Some products may not be available in your country please contact our distributor for more details The high speed dome camera series are designed for in and outdoor video surveillance applications The integrated motorized pan tilt mechanic allows users to maneuver the camera to any position 360 horizontal and 180 vertical Both series can be equipped with digital zoom camera modules which provide zooming functon from 18 to 36 times optical and advanced image features Key features 360 Pan and 180 Tilt range 90 with auto image flip Support most well known camera modules 128 pres
25. ributor for more details OSD Menu The speed dome are equipped with the new OSD Menu function All operational functions and camera related settings can be controlled here In order to use the OSD function a telemetric controller device such as keyboard DVR or other devices with similiar functions is required Please make sure that the device used is properly physically connected to the dome and all connection parameters are set How to start the OSD Menu To start the OSD Menu you need to press the following sequence on the keyboard With keyboard call 9 5 Enter or 2 call 9 Enter With keyboard Shot 91 5 Shot 9 Enter 3 Axis In case a DVR is used for operating the OSD select go to preset 95 or 2 X go to preset 9 Please refer to the DVR s operation manual for more details Note that in some situations it is not possible to access the OSD menu 1 The dome is running a tour 2 Performing PTZ operations 3 Dome is receiving a command other than OSD request from the keyboard To solve this inability stop the operation and try again Main menu and navigation After entering the OSD Menu the screen will show menu items Use the controller s joystick to navigate the Main Menu menu s main and sub items by moving in the desired direction The angle mark on the beginning of every item gt SYSTEM SETT
26. s dome label temperature and display of various values on the operational screen Dome Label 1 use UP or DOWN to change the character 2 use RIGHT to move to next character 3 use RIGHT to move to last char and to save 4 use Left to go to first char and to cancel Initial Info Shows the information about current settings Display Setup Enables the display for the on screen info during operaton mode Dome label Name of the dome Preset label Shows the label of every preset Zoom label Shows zoom factor on screen Zone label Shows the zone name Direction label Shows the coordinates Temperature label Shows the current temp in the dome Some products may not be available in your country please contact our distributor for more details 6 OSD Motion Clear Password MOTION FLIP ON PROPORTION ON PARK TIME 005 PARK ACTION SCAN POWER UP ACTION AUTO FAN ENABLED 040 BACK EXIT CLEAR CLEAR ALL ZONES CLEAR ALL PRESETS CLEAR ALL PATTERNS CLEAR ALL TOURS CLEAR ALL WINDOWS FACTORY DEFAULTS RESTART BACK EXIT PASSWORD SETUP OLD PASSWORD NEW PASSWORD CONF PASSWORD ENABLE PASSWORD OFF BACK EXIT Motion control AUTO FLIP Auto image flip tilt range from 90 to 180 PROPORTIONAL PAN Depending on the zoom factor the dome will adjust the pan and tilt speed automatically for comfortable viewing PARK TIME D
27. the surveillance area you can set the AE in different modes and adjust the parameters such as shutter speed iris factor and brightness for the best image quality WB MODE White Balance mode an image improvement based on DSP processing You can also adjust the Red Gain or Blue Gain to change the color tone Hi RESOLUTION Switch between 470 530 TVL only with FCB 1010P FUNCTION SETTING PRESETS SCAN PATTERNS TOUR ZONES gt BACK EXIT PRESETS PRESET NUMBER 001 SET PRESET SHOW PRESET CLEAR PRESET EDIT PRESET LABEL BACK EXIT EDIT PRESET LABEL LABEL MAINENTR BACK EXIT SCAN Some products may not be available in your country please contact our distributor for more details SCAN NUMBER 01 SCAN SPEED 63 SET LEFT LIMIT SET RIGHT LIMIT CLEAR SCAN RUN SCAN EDIT SCAN LABEL BACK EXIT Function Setting In function setting menu you can define and activate different PTZ funcitons such as preset points auto scan tours and patterns Presets and tour functions can also be set or activated directly from the keyboard without entering the OSD Menu Please refer to the keyboard s manual for operation details Presets PRESET NUMBER supports up to 128 presets The number can be selected from 0 to 128 SET PRESET Defining the preset points directly in OSD by entering this menu item and move the PTZ Press IRIS OPEN key on the keyboard to sa
28. ve If the preset is pointed within digital zoom it will automatically go back to the max optical zoom range in order to provide the best image quality SHOW PRESET Moves to the current preset point CLEAR PRESET Clears the current preset EDIT PRESET LABEL For the current preset you can define a name which will be displayed on the operation screen once the preset is called Please choose the preset number first The avaialbe characters are 0 9 A Z lt gt and space Scan The SCAN function moves the PTZ between 2 predefined points with constant speed The following parameters can be set SCAN NUMBER Supports up to 4 scans SCAN SPEED Cruising speed between the points SET LEFT LIMIT Defines the left point SET RIGHT LIMIT Defines the right point CLEAR SCAN Deletes the scan setting RUN SCAN Starts the scan function EDIT SCAN LABEL Sets the name for the scan 16 Some products may not be available in your country please contact our distributor for more details PATTERNS PATTERN NUMBER 1 PROGRAM PATTERN RUN PATTERN CLEAR PATTERN EDIT PATTERN LABEL BACK EXIT TOURS TOUR NUMBER 1 EDIT TOUR RUN TOUR CLEAR TOUR BACK EXIT EDIT TOUR PO S TM PO S TM PO S TM 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00

Download Pdf Manuals