Home

IR MANUAL PDF - GSM Activate

image

Contents

1. 2 01798856323 3 01798898765 Max 3 numbers Note You can only send one number at a time it is important to wait until you receive a text acknowledgement STORED before sending the second number This may take some time depending on how busy your network is If you wish to cancel a number follow this example Hash 1 or 2 or 3 Star Star 1 Then send this as a text to the simcard Below is a notepad to help you remember the names and numbers that you have saved to your simcard in the event you need to modify or delete In the future 1 2 3 Now you have the simcard programmed please make sure that you have set Dipswitch 1 to ON if you would like it to make a phone call to you Dipswitch 1 OFF if you would prefer to Receive a text message Page 7 7 How to turn on the Alarm Module At this point to turn on the alarm you simply send a text message command Activate to the alarm it will send you a text message acknowledgement back Alarm on To switch off the alarm send the text command Deactivate When the alarm has been triggered it will revert to standby To reactivate the alarm you will need to send the Activate command again Alarm output relay This is a dry contact relay which can be used to activate auxiliary equipment or external alarm systems The relay has a COM amp N O contacts 3Amp Load Signal strength max To help make sure that you place the unit in a suitable position
2. on 7 Alignment of the infrared beams There are two adjustments left and right and up and down the photo below should give you the indication of how to do this Receiver unit Green led confirmation of good alignment Alarm on led Brightness varies depending on instinctive level It is possible to align the infrared beams using a multi metre You can do this by placing your two metre leads into the side of the receiver you should have a voltage reading of proximity 2 5 volts to 4 volts the higher the voltage the more aligned the beams are Vertical alignment Adjustment screw Horizontal adjustment Left Alignment Right The voltage adjustment is only available on the receiver unit 8 When you re satisfied that the transmitter and the receiver are in alignment which will be indicated by the green led turning on you can then carry out a walk test By interrupting the infrared beam the red alarm light on the receiver should come on for approximately 4 seconds if this is the case then the unit is now working properly Page 6 6 Programing the GSM Alarm Module You are now ready to start programming the GSM module this will allow the unit to send a Text message or phone call depending on how you set the unit up but first you need to program the simcard with the telephone numbers maximum 3 numbers Example Hash 1 or 2 or 3 Star phone number star 1 01798123456 Then send this as a text to the simcard
3. you can text the unit to see how much signal strength you have by texting SS this will indicate the strength of the signal you will receive a text telling you if it s good average poor signal we strongly recommend that you place the unit where you can get at least average signal you will find that with a poor signal it will be unreliable and is not suitable 3 metre signal booster cable is available from our sales department Telephone 0800 772 0783 or for technical support 0800 2461583 Email sales gsm activate co uk Web www gsm activate co uk Quick reference Send Text Activate Deactivate SS 1 123456 79989 V1 08032015 Operation Turn Alarm on Turn Alarm off Check signal strength To store phone number 1 To delete phone number 1 Page 8 Acknowledgment Alarm on Alarm off Good Ave Poor Stored Deleted
4. 1 to ON position and the infrared beam has been triggered you will receive a telephone call alert After six ring tones the call will automatically hang up you do not need to Answer the call Dipswitch 2 OFF If you select Dipswitch 2 to OFF position the alarm output relay will trigger for 10 sec every time the beam is broken regardless if the alarm has been switched ON or OFF Dipswitch 2 ON If you select Dipswitch 2 to ON position the alarm output relay will only trigger when the beam is broken and the alarm is turned ON Page 3 12 24 Vde Input m L eod Fal 4 M ill Alarm output if required E Ml ceann Aad pak jeans OM Hr E E E E Ty 3 ST Dipswitch 1 Off will send Text message Dipswitch 1 On Phone call gt Boa Dipswitch 2 OFF The alarm output relay will trigger when the alarm has been set to ON only and the beams have been broken ala 1 Dipswitch 2 ON The alarm output relay will trigger if the alarm is ON or OFF and the beams have been broken IMPORTANT PLEASE READ Please make sure you disconnect the power when you fit the Simcard AND YOU PLACE THE SIMCARD WITH THE CLIPPED CORNER FACING OUT WARDS PLEASE LOOK AT PICTURE ABOVE 4 Output relay The output relay connection can be used to trigger an external alarm system or auxiliary equipment even a door bell When the infrared beam has been broken the output relay will latch on fo
5. O RCTIVATE GSM PERIMETER amp INTRUDER ALARM Remote Monitoring amp Control using your mobile phone www gsm activate co uk Product Information Our GSM Perimeter and Intruder alarm system can be used for indoor and outdoor purposes the transmitter and receiver can be placed up to 100 metres outdoors and 300 metres indoors placing two invisible beams between each other when the beams are broken it will trigger the alarm and using the GSM technology it will send you a text message or phone call to your mobile phone or land line to alert you Fra Frequency Quad band Freq 850 900 1800 1900 Z Power Supply Voltage 12 24 Vdc2 Amp max Current used in standby mode 25 ma max IP Enclosure rating for outside installation 3 Amp Relay output Standard 2G simcard No Landline Required Dimensions L175 xW100 xH90mm Transmitter Dimensions L175 xW100 xH100mm Receiver Operating Temperature 10 40 C sensor range 100m outdoors 300m indoors Autorreset Dipswitch setting for call or text alert Text for signal strength Stay Active Sim Function Programme Simcard by Text message Table of contents 1 setting up the gsm module 2 Fitting the simcard 3 Selecting the dipswich Text Phone call 4 Relay output 5 Installation of the infrared beams 6 Programming the gsm alarm module Page 2 I Setting up the GSM Alarm Module New simcards will need registering before they can be used Full details of how to do this can norma
6. lly be found in the simcard pack It will pes require that the simcard is inserted into a mobile phone a number dialled and instructions followed While the SIM is in the mobile phone it would be a good time to disable any PIN codes call diverts ring back and disable features such as voicemail and text alerts details of how to do this is found on the simcard provider s web site or by calling their customer services Please use one of the following SIM card providers Vodafone TMobile O2 Giff Gaff or Orange EE we do not recommend the three network Please note the GSM Perimeter and Intruder alarm has a built in sim active function which keeps track of the unit s activity and if there has been no usage for 6 weeks it will send out a text message to a preset recorded number to keep the simcard alive this then eliminates the problems of simcards being shut down if they are unused for 3 months 2 Fitting the simcard Ref to page 4 1 Slide back the sim door and lift it up 2 slide the simcard in to the door making sure that the clipped corner of the simcard lines up with the clipped corner of the sim holder 3 Close the sim door 4 Slide the sim door to lock the simcard in place oe Selecting Dipswitch Ref to page 4 Dipswitch 1 OFF If you select Dipswitch 1 to OFF position and the infrared beam has been triggered the unit will send you a text message Alarm Triggered Dipswitch TON If you select Dipswitch
7. r approximately 10 seconds Note The GSM alarm system does not have to be activated for this to happen when the IR Beam has been broken the output relay will always toggle ON and OFF Please ref to Selecting Dipswitch on page 3 Page 4 5 Installation of the infrared beams 1 Find a suitable location for the transmitter and receiver and ensure the sensors are mounted on a stable structure 2 When installing the receiver take care to position the receiver out of direct sunlight as this will reduce the sensitivity 3 Ensure the sensors line of sight is free from false alarm sources such as bushes trees etc Pay attention to these they may change seasonally 4 It is important to have the correct Power Supply to operate this device successfully You will need a 12 volt 2 Amp supply or 12 volt battery you can purchase both of these from the website www gsm activate co uk 5 Below is a photograph of how to connect the transmitter and receiver if you are going to use the relay alarm output you will need to refer to the diagram Below To Bell Alarm systems Lights ect KUE FIITGE j hete dr em If required T LIVE INFRARED SENSOR Shae EEE 12 Volt Supply TT Receiver Transmitter Page 5 5 Installation of the infrared beams continued 6 Now you have the transmitter and receiver fitted to the location you can carry out alignment you will now need to turn the power