Catella PACS 5.0 Web Viewer User Manual

image

Contents

1. Please note the measurement details will appear in the default color and font Refer Annotation settings on page 43 to set the default measurement settings To change the default line and fill color settings and the location of the lines double click the line A Set Properties dialog as shown below will open Set Properties Left 176 Top p DN MEOUES Line Style Solid Line 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 23 A D AMD Technologies Inc Catella 5 0 Web Viewer User Manual Eme Specify the left X and top Y positions width and height of the measurement rectangle Then select the line color line width and line style Finally click OK 4 1 23 Apply Window Level Presets This feature of the CATELLA PACS 5 0 Web Viewer Application helps you to apply predefined Window level presets to the selected image To do this Right click the image and select appropriate preset name from the Pop up You will notice that the window width and level of the image being adjusted based on the selected preset Please note that all the presets corresponding to the modality to which selected image belongs to will be listed out in the Popup Refer Modality Settings for adding or editing the presets 4 1 24 Mark key Image This option of the viewer helps you to mark the important images of the currently opened series as key image for future reference report preparation etc To do this select the requ
2. AMD Technologies Inc 218 Bronwood Avenue Los Angeles CA 90049 3104 T 310 470 8900 T 800 423 3535 F 310 471 8900 W digitalams com W ams4illuminators com E info digitalams com Catella PACS 5 0 Web Viewer User Manual 10 X J A1010200 Initial Draft 2214146 4 032020090 Updated Document K 22148 0416 200 9 Updated Document KO 22 4 7 05132010 Updated Document K 22 1 77 05192010 Updated Document K 22 1 76 4 07092010 Updated Document K Ooo T S S O SEE EE A D AMD Technologies Inc Catella 5 0 Web Viewer User Manual M Table of Contents Chapter 1 Getting Slarled iion en oie rate tua tte ces deco ua rate reader R eters ETEA E Ue cutus Deeds AEEA 4 jer m 4 ke Wr riii S 4 prom Uc ct 4 Chapter 2 S0 tWare Select isa fore areca ie ooa A es eiie u Eso e Do cdUo O D NUR x UE 4 This chapter describes how to logon to the CATELLA PACS 5 0 Web viewer and also explains the menus available in the CATELLA PACS 5 0 Web Viewer Interface 2 4 ZAR Prae oreet S 4 ZELUS ael EL LP TET m 5 Chapter 3 Query and Load DICOM Files eller rere esee ene e sense nau a aun nana ass
3. To edit Window level preset 1 Select the modality and then select desired preset name from the displayed list of presets Click on the Edit button in the Modality Settings Dialog 2 The Presets Dialog opens Make the required changes in the Window width and Level and click on the OK Button y The Preset Name is restricted from editing 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 33 AMD Technologies Inc Catella 5 0 Web Viewer User Manual To delete Window level presets 1 Select the modality and then select desired preset name from the displayed list of presets 2 Click Del button A Confirm Dialog opens Click on the OK Button to continue 6 3 Annotation Settings This functionality enables you to set the properties of the annotation options like line arrow rectangle ellipse or circle and the text marked on the image On clicking the Annotation tab in the CATELLA PACS 5 0 Web Viewer Application Setting Dialog the option to change the line fill and font settings will be displayed in the Application Settings Dialog Application Settings Modality Annotations Filters Reporting Line Settings Fill Settings Font Settings E Font Measurement Font Clear v Solid Line Y ee ee Line Color Select the default color of the line to be drawn on the image Line Width Lege width of line drawn on the image Range should be from 1
4. 20 JPEG Extended 1 2 84 WINDOW LEVELLING PRESETS Chest Abdomen Lung Brain Bone Head Neck The primary elements in the Modality Settings Dialog are listed below 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 32 a A D AMD Technologies Inc Catella 5 0 Web Viewer User Manual LAE Image Layout Select the default series layout for the selected modality interpolation for the modality selected Level window for the chosen modality Select this option to display image attributes nieplavin Checking this displays the modality in the Search Screen thus S p ay helping you to query the studies corresponding to the modality earch using the search option Imaae Orderin Displays the images of the series in ascending or descending i i order of their slice number Add To add window level presets for the selected modality mE EMEN To edit the selected window level preset To delete the selected window level preset To save the settings Start in WL The dicom images should be displayed with the default window mode level presets C HIererreg ption to select the compression mode ompression 6 2 1 How to Add Edit Delete Presets To add Window level presets 1 Select the modality for which the preset is applicable Click button in the Modality Settings Dialog 2 APresets Dialog opens Specify the Preset Name and the Window width and Level Then click OK button Presets E 1500 600
5. 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 11 X A D AMD Technologies Inc Catella 5 0 Web Viewer User Manual Em LT Angle formed between a line drawn parallel to the superior Cobb Anale endplate of one vertebra above the fracture and a line drawn e g parallel to the inferior endplate of the vertebra one level below the fracture FEE Line with Midpoint Draws a line with the mid point highlighted ese an arc and indicates the arc degrees and the leght of a between the start and stop point Single line will be made like a line but when user releases at Horizon Angle the end point the line displays across the entire film The dangle that is displayed is the degrees of this line to a horizontal line Start with using the same process as a hortizon line User picks a point in the line and pulls up or down from this point to Horizon Orthogonical Angle create a perpendicular line Both the horizon angle and length of the perpendicular line are displayed Holding the end of the perpendicular line will allow the T to be moved or rotated Pleses L and R labels on the image First label is L and E Left and Right Markers secand labels Press the down area next to this button to display the choices Cervical C1 C7 Thoracic 1 T12 Lumbar L1 L7 Socral pube S1 S5 Select the label you wish to atart with in any series and then click on the point you wish labeled The next click will place the next sequenti
6. General settings in the Preferences The images will be downloaded as thumbnails as shown below If you wish to download the selected images right click on the mouse and select the option to either download using default compression or download images using any one of the listed compressions in the context menu 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 31 ae A D AMD Technologies Inc Catella 5 0 Web Viewer User Manual CLAE Download using default compression Implicit VR Little Endian Explicit VR Little Endian JPEG Baseline JPEG Extended JPEG Lossless JPEG Lossless First Order RLE JPEG 2000 Lossless JPEG 2000 Lossy Presets Processing Mode Display Delete all annotations Reset Level and orientation Select all images Export images to powerpoint Create AVI file From series Note This functionality is only available with the CatellaDcmServer exe version 2 2 1 245 6 2 Modality Settings This functionality enables you to set the image layout zoom interpolation image attribute display condition and window leveling presets for each of the modalities like CR CT MR etc On clicking the Modality Settings Tab in the CATELLA PACS 5 0 Web Viewer Application Settings Dialog a Modality Settings Options appears in the Application Settings Dialog as shown below Application Settings General Modality Annotations Filters Reporting R SS Cae Wd Ced o P i ME AE S AIE I A A
7. administration There 1s no evidence of any intra or extra hepatic dilatation of biliary radicles Portal vein and IVC are normally enhancing after contrast administration Common Bile duct 1s normal Gall Bladder Gall Bladder is sub hepatic in position and shows normal attenuation values E Pancreas Pancreas is normal in size and shows normal attenuation values No evidence of any focal mass lesion or calcification Pancreatic duct is normal Spleen Vertical scan length of the spleen is 09 0 cms Spleen is normal in size and shows normal attenuation values Both adrenals are normally imaged No evidence of any abnormal mass lesion or calcification in the adrenal glands Kidneys Both kidneys are normal in size and shows normal attenuation values There 1s no evidence of any abnormal mass lesion or calcification Both Kidneys show normal concentration and excretion of contrast media Both ureter are normally visualised stomach Ascending colon transverse colon Caecum and Descending colon are normal Ee 0 i Cael Enter the Template name and select the modality which corresponds to the Report Template lt If you want the report template to be visible to all users check the Public checkbox Then type in the necessary report details and change the font settings of the text using the Formatting Toolbar if required Once you are done with the report preparation click on the OK button to save the report Template To
8. AMD Technologies Inc Catella 5 0 Web Viewer User Manual click the Q button or right click the image and select Reset Level and Orientation option or press the F2 Key in the keyboard 4 1 5 Change Window width and level To change the window width and level Click D button or Right click the Image Review Region and select Mode Window Level option from the Pop Up or Click the w key in the keyboard Left click and drag the mouse pointer over the image 4 1 6 View Hounsfield of image To view the Hounsfield of the image Click ada button or Right click the Image Review Region select Mode gt Hounsfield option from the Pop Up or Click the H key in the keyboard Left click and drag the mouse pointer over the image to view the hounsfield of that image portion 4 1 7 How to Draw This section describes the procedure to draw a line arrow rectangle or ellipse on the image Draw a line on the image c 1 Click button Of Right click the Image Review Region and select Mode gt Line from the Pop Up Or Click L key in the keyboard 2 Left click and drag the mouse to draw a line on the image Draw an arrow on the image 1 Click button Of Right click the Image Review Region and select Mode Arrow from the Pop Up Or Click A key in the keyboard 2 Left click and drag the mouse to draw an arrow on the image Draw a rectangle on the Of 2010 AMD Technologies Inc D
9. Edit the report Template Double click the desired report template name or select the Report Template name and click on the Edit button in the Reporting Dialog shown in page 55 Make the required changes in the report template Then click on the ok button to save the changes To delete the selected report template Click on the Delete button 7 3 How to design a new Report Header To design a new report header Click on the Header Designer button in the Reporting Dialog shown in the page 55 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 39 EEG A D AMD Technologies Inc Catella 5 0 Web Viewer User Manual A Report Designer Window as shown below will open Report Header Designer W Letterhead Margin 200 Font Name Ba rx x E EXESESERERERER ERE ERE fail Formatting Toolbar Report Header Area To include center information click on the Center Information Tab If the letterhead is to be included in the Report select the Use Letterhead check box and enter the top margin value Notes The top margin value indicates the space between the top of the page and the patient information grid The top margin value is in pixels not in cm or inches Otherwise type in the required details You can change the format of the text such as font indent position alignment etc in the Reporting Region using the formatting toolbar Note 1 Pressing the Enter key in the keyboard will result in double line spacing betwe
10. L PRIMA 3 26 2002 12 48 21 PM 1 2332 200035 3123 100 11 12 10 1 2 840 10008 5 1 4 1 1 2 1 2 3392 200035 3123 100 11 12 10 3 26 2002 9 26 2002 12 20 36 FM 12 46 22 PM NULL CT Hitachi Medcal Comnorahben Barve Lal NULL Pront HHE HHC CT I0 Unkncem Data Type Lachh iam iDODODOO137 NULL Page 18 ae A D AMD Technologies Inc Catella 5 0 Web Viewer User Manual M 3 Click the OK Button to continue 4 1 14 Export Image to desired storage location To export the image to a desired storage location 1 Select the desired image in the Image Review Region 2 Click see 3 A Select Destination Dialog opens Button Select Destination un Target Deve c Output Format JPEG Fies 4 Select the Target Drive and Output Format and Click on the OK Button 4 1 15 Export Images as Powerpoint To export the selected image to an existing Powerpoint presentation file or a new presentation file 1 Select the images right click and choose Export images as PowerPoint 2 A Presentation dialog will appear Presentations Mew Presentation Insert inta file 3 Click on New Presentation to export the image to a New Presentation file 4 To insert the image to an existing presentation click Insert to File option An Open dialog will be displayed Select the file and click Open button Note The option above will work only when Microsoft PowerPoint is installed in
11. Manual Click is button Of Right click the Image Review Region and select Display option from the Pop Up and then click the appropriate option like 1x1 in the Submenu Note Pressing the 1 2 3 keys in the keyboard will display appropriate number of images in the image review screen To decrease the number of images displayed per page Click l button 4 1 12 Send the selected image to a print composer To send the selected image to a print composer Right click the Image Review Region and select Send to composer option from the Pop Up Or Press F5 key in the keyboard y The Printer is to be configured before enabling this option 4 1 13 View DICOM Attributes To view the DICOM attributes of the selected image 1 Right click on the Image Review Region and select Image Attributes option from the Pop Up 2 A DICOM Attribute dialog opens as shown below DICOM Attributes x Group Element Description Wale Image Type neers Creation Date Inana Creation T nme Ingtance Lreaor UID SOF Class UID SOP Instance UID Study Date Image Date Study Time lenauge Time Accesuon Numbes Modaity M anol scturer Intibulion Name Helenmng Prescians Name Manutacturer s Model Name Prreaba Creator Privabe Creador Unknown Element 3 1100 Falieril s Hane Patera ID Patert s Bath Date Pizilza Fa 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Muliple values ORIGIMA
12. SE os E 6 ERHSGE fi fizz TOINX14IN v Size Orientation rn EE Clear The names of all the DICOM Printers or the Network printers connected to your machine will be listed out in the Select Printer combo box Select the appropriate printer name Please note The print layout changes depending on the default print layout set for the selected printer Now select the print layout that indicates how many images to print on a single sheet For example selecting the i option helps you to print two images on one sheet of paper You can also design your own print layout by selecting the required number of rows and columns using the Rows Columns Option Right clicking and selecting Split Vertically Horizontally from Popup can split the selected cell accordingly 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 26 e A D AMD Technologies Inc Catella 5 0 Web Viewer User Manual CANLA To merge the adjacent cells right left upper and lower cells right click and select Merge with Right Left Upper Lower Cells from the Pop Up as shown below Archive Image Viewer PrintComposer Preferences HEITIS mmm m ESRREE TEMENE You can import required DICOM images to empty cells of the print composer window by right clicking and selecting Import DICOM File A Browse For Folder Dialog will pop up on your screen Then locate the desired DICOM Files and click OK Right clicking and sele
13. a aaa anna aaa RR RR aaa n nn nnn 6 3 1 Query from the DICOM Server ee eee e Li ieeeeeeeeceu i eene eene sean ana a saa n sea assa asas sn seas ananas 6 J2 E030 DICOM File e 7 3 3 Load DICOMDIR m m 8 JA TOWING SUS 9 o ieii ig Ay TAOS VIC WSN t 9 41 mag Viewer OV ET VIG T a 9 4 1 1 Deselect an Annotation LOO i eondeiouuc sd iin d ra sats qua eU rar va d da pae del ea wa ERE Rv KG d 12 WEN Avete mina E NETT mU TM 12 4 1 39 Rotate Flip and Invern IMAQS caseoquxtusistend Yates iesus v RguS uw aaia URL UU adi aka e aon 12 4 1 4 Reset Level and Orientation of IMaQC ccccccssssecccccseseeeeecceeeeeeeeseeueceeesaeaeeeesssaeeeesessaseeees 13 4 1 5 Change Window width and level ccccceecccccceseseeeeeeeeeeeeeeeeeeeeeeeeeeseeeseeeesseeeeeeeessaaeeeeeesseeeeees 14 4 1 6 View Hounsfield of IMAGC ccccssesecccccsessececccseseccecceeueeeeesseaeeeeesseaeeeeessaugeeeesssaaeeeesssaaseress 14 QA SE FOW WO Bc Fe RTT 14 4 1 8 Include text on the Img eoe ipe rana Eee denuteceusengrad Eee koe Fexna ses PesucoG exe etkPuS Pepe n eere parer teen ede 15 4 1 9 Adjust the Display Parameters of the image cccsesccecsseeeeeeseeeeeeeeeeeeseeseeeseaeeeeeeaee
14. aaeeeeeessaaees 33 b 3 ANNON Se HOS saisis cube sates vuderncusbea Due ipsu dues usb ivc e mmus rou aueedsocuteryiaedudessauctesueseousan Ud 34 0 4 Fier an ET PIE c n 34 Chapler 7 ri oolguB sig E M 37 7 1 GCat gorize Rep rt Templal s EE SER 37 VOV DESIN FRE DONG TEMPIE tT 38 7 3 How to design a new Report Header ccccccccssssseecccsesseeeseceesseeeseeesseeeeeeenseeeseoensseeeseoeeneeeesens 39 7 4 Reporting Procedure 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 3 A D AMD Technologies Inc Catella 5 0 Web Viewer User Manual ed Chapter 1 Getting Started 1 1 Overview The web based CATELLA PACS 5 0 Web Viewer is the ideal DICOM viewing and image manipulation tool used by radiologists and physicians to access the studies from any remote computer connected to the Internet via a secure password protected login It can be easily configured in any PACS environment 1 2 Features Accessible anytime anywhere via a PC with an Internet connection Fully compliant with the ACR NEMA DICOM 3 0 standard Individual upgrading of a PC is eliminated when a new version or upgrade of software is released More user friendly 1 3 USE Used in small to medium sized medical imaging centers or hospitals for diagnostic viewing and manipulating medical images Chapter 2 Software Setup This chapter describes how to logon to the CATELLA PACS 5 0 Web vi
15. ait or Landscape After carrying out the required print settings click on the Print Button to print the images Note 1 Orientation indicates how the document is positioned on the page Portrait orients the print vertically while landscape orients the print horizontally 2 As there is no print preview option ensure that you have selected the correct images before the printing operation You can use the Clear Button to clear all the images in the Print Composer Window 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 28 AD AMD Technologies Inc Catella 5 0 Web Viewer User Manual Chapter 6 Preference Settings Once CATELLA PACS 5 0 Web Viewer is installed you have to set the General Modality Annotation Filter and Report settings before you start working with the CATELLA PACS 5 0 Web Viewer application This chapter describes each of the settings in detail 6 1 General Settings This functionality allows you to set various general settings like the default series layout for the image review window default DICOM printer etc On clicking the Preference Button in the CATELLA PACS 5 0 Web Viewer Main Screen an Application Settings Dialog opens Application Settings Save General Settings Change Password The fields in the General Settings Dialog and their descriptions are listed below Descriptions Series Layout Select the default series layout for the image review window Select the de
16. al label on the film For example select S2 for the first label and the next label will be S3 Copying and Moving Annotations To copy an annotation click on the annotation press Control C to copy To move an annotation click on the annotation move the pointer to the new location and then press Control V to move 4 1 1 Deselect an Annotation Tool To deselect the selected annotation tool or to activate the mouse pointer Click N button or Right click on the Image Review Region and select Mode gt Select or Press the Esc Key in the keyboard 4 1 2 Zoom and Pan Image To zoom and pan the whole image Ih Click button or Right click on the Image Review Region and select Mode Pan Zoom from the Pop Up Left click and drag the mouse over the image zoom in or out the image To pan the image right click and drag the mouse To zoom a specific region of an image Right click the Image Review Region and select Mode gt Lens Left click and drag the mouse over the image Refer Modality Settings to set the zoom window size and zoom percentage 4 1 3 Rotate Flip and Invert Image 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 12 S A D AMD Technologies Inc Catella 5 0 Web Viewer User Manual You can use the Rotate amp Flip options to flip or mirror the entire image and to rotate the image according to the number of degrees specified You can also view the negatives of the image using the Invert option Th
17. cting Remove DICOM File will remove the DICOM image from the particular cell Select the number of copies you want to print If required you can zoom in or out the images in the desired cells of the Print Layout Window by clicking on this L5 T button and left clicking and dragging the mouse over the image To pan the zoomed image right click and drag the mouse over the image with the S i button being selected You can change the window level of the selected image by clicking on this p button and left clicking and dragging the mouse over the image To print only a certain circular or rectangular area of the image click on these c 2S Shutter buttons respectively and drag the mouse over the image You will notice only the image area that you have defined being displayed as shown below Please note 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 27 A D AMD Technologies Inc Catella 5 0 Web Viewer User Manual en To remove the shutter i e to view the entire image right click the image and select Remove Shutter Click button to get the mouse pointer or to deselect selected button zoom and pan button window level button and shutter button Archive Image Viewer Windong p L LT am LE adjuste age 1311 E EE EE ESE Gr EE 4 General Now select the paper size on which you want to print the images and then select the paper orientation either as Portr
18. e table listed below gives a quick overview of the procedure to invert rotate and flip the images Rotate Image to Left by 90 Degrees or anticlockwise direction Rotate Image to Right by 90 Degrees or clockwise direction 5 Click button or Right click the Image Review Region and select Processing gt Rotate Left option from the Pop Up or Click Ctrl lt keys in the keyboard r Click Button or Right click the Image Review Region and select Processing gt Rotate Right option from the Pop Up Or Click Ctrl gt keys in the keyboard Click A Button Or Right click the Image Review Region and select Processing gt Flip Vertically option from the Pop Up Or Click shift lt keys in the keyboard Flip Image Vertically Click E button Of Right click the Image Review Region and select Processing gt Flip Horizontally from the Pop Up Of Click shift gt keys in the keyboard Flip Image Horizontally Click button Of Right click the Image Review Region and select Processing gt Invert Image from the Pop Up Of Click I key in the keyboard Invert the RGB value of the image or view the negatives of the image 4 1 4 Reset Level and Orientation of image This option is used to reset the level and orientation of the image after zooming rotating or flipping the image To reset the image 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 13 A D
19. eesaaeeeeens 17 4 1 10 Display Hide Overlays on the image ccccceseeeeceeeceeeeeeeeesaeeeeeeesaeeeceeeseaeeeeeeessaaeeeeeessaeeeees 17 4 1 11 Change Image per Page ccccccccccssscecceesseecceeseecceeeseecseueeeeceaseeessaeeeeseuseeessueeessageeesssaseneess 17 4 1 12 Send the selected image to a print composer esseesssssesseseeeeeneennnne 18 4 1 13 View DICOM Attributes sseeeeesesssseseeenennnnnnnnnnnnnnnmnne nennen nnne nennen enirn nnn nns n naar nns 18 4 1 14 Export Image to desired storage lOCAtION ccccseeeeeceeeeeeeeaeeeeecseeeeeceeeeeessaeeeesaeeeeesaaeeeeens 19 4 1 15 Export Images as Powerpoint cccccccseeeececeeeeeecaeeeeeeseeeeeeaeeeessaaeeesseeseeessaeeeesegeeeesseeeesens 19 4 1 16 Select All IMAG TE ET 19 AmUNCIC AVIBI Se 20 4 1 18 Send Image to Remote Node eessssssessssesesseee nennen nennen nnn nnns nnn nnns 20 A NA Oe TAY Fale TI T OTT 20 4 1 20 Linear Measurement ccccceecccesececeeeeeceueeeceueeeseeeesaeeseaseessaeeeseasessaueessaueessaseessueeessnseesaaees 21 4 1 21 Area Measurements scaeisqdurxpensunrnbka duskEu VR RDXERR EY ER CA IEA Uk Ee EE cond Uf aveRN DER al DEI rYN PUERO nhF EOS ER 21 4 1 22 Angular Measurements ccccceeeeccceeeeeeceeeeeeeceaseeeceaueeeeseaseeessaeeessaaeeeeseaeeeessageeessaeeeeessaeeeseas 23 4 1 23 Apply Window Level Pre
20. eld View Hounsfield value of the image Lens Mode Zoom in specific region of the image i h LES Adjust sharpness enhancement window width and level of the image Annotation Options Draw a line on the image Adjust Image C D D on D oO lt D e C o o Q 2 cC D Line Arrow Draw an arrow on the image Rectangle Draw a rectangle on the image Circle Draw a circle on the image Text Type text on the image Free Hand Tool Draw free hand polygonal shape Save Save annotations a Navigation Options Increase the number of images displayed per page Decrease the number of images displayed per page View the previous page View the next page Move to the First page Move to the Last page E Export Images Export the selected images to a desired storage location a Display Hide Overlays Display hide the overlays on the image Multiframe Playback Options Play a DICOM Avi Play the DICOM AVI Please note to increase the playing speed of the AVI press the key in the keyboard Use the key to reduce the playing speed of the AVI Measurement Options Carry out linear measurements on the image Angular Measurement Find angle between two different points on the image Elliptical Area Measurement Read the area of the Elliptical Region of Interest ROI of the image Rectangular Area Read the area of the Rectangular Region of Interest ROI of Measurement the image
21. elected remote DICOM node To do this click on the in the Archival Screen and then select the desired remote node or right click on the selected the image s and choose Send to Remote Node and then select the desired remote node Please note All the nodes that the administrator has added using the Server Application will be listed out here 4 1 19 Play Frames To play all the frames of the selected series in a loop click e button and a Cine dialog pops up Now select the playing speed as slow normal or fast And then click the Play button gts To E stop the playing click the Stop button E z i j i j S low Normal Fast ESES 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 20 ALD AMD Technologies Inc Catella 5 0 Web Viewer User Manual 4 1 20 Linear Measurement The Linear Measurement Functionality of the CATELLA PACS 5 0 Web Viewer Software helps you to measure the length of the desired part of the image in mm To do this click b button in the Image Review Window and drag the mouse to draw a line from the desired point of start and end on the image You will notice a line with its length displayed on the image as shown below Please note the measurement details will appear in the default color and font Refer Annotation settings in page 43 to set the default measurement settings To change the default line color settings and the location of the measurement line double click the measurement
22. en the text lines Use Shift Enter keys in the keyboard for single line spacing between the text lines 2 The font size available in the Report Master does not correspond to other window applications Here 128 pt 2 10 pt 3 12 pt 4 14 pt 5 18 pt 6 24 pt 7 36 pt 3 If tables or a logo are to be included in the report then create the same in MS Word MS FrontPage and copy and paste it in the report Report Header Designer ff Letterhead Margin 200 Font Mame Size E Y a ESEIESESERERSESESESESESERAESERE i AMD Technologies Inc To include the Patient information click the Patient Information button in the Report Header Designer Dialog and type the required details Then place the cursor in the required location of the Report Header area select the required fields from the Field drop down list and click on the Add button Say for example if you like to include the Patient ID in the Patient Information Grid of the Report click at the position where you want the patient id to be displayed in the Report header and then select ID from the Field Drop Down box and click the Add button 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 40 4 p MIENE AMD Technologies Inc Catella 5 0 Web Viewer User Manual Note If you want to include a table in the Report Header area create the same in the Microsoft Word or FrontPage and copy paste it in the Report Report Header Design
23. er Patient Hame PatientlName Patient ID PatientID study Date otudyDate study Description otudyDescnption Click on the ok Button and specify the Report Template Name 7 4 Reporting Procedure This functionality of CATELLA PACS 5 0 Web Viewer enables you to create a Report for the selected study using preset report templates A Reporting Screen as shown below appears on clicking the Report option in the Study Information Display Region in the Image Viewer Screen Please note that the reporting functionality is available only for the studies in the local archive pm Archive image Views Print compose M ENNELCENENEEN LL CNN ee T ea Sare Papert Prates Papert Er j j l 1 i toni Hare z ope a poppe pz pe CA ERE CLER EA EA ELE Formatting Toolbar Reporting Area The reporting screen comprises fields as listed below 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 41 AMD Technologies Inc Catella 5 0 Web Viewer User Manual Fede Denon Series Select the image series for which a report has to be prepared Report Layout Select a report layout type Template Select a predefined template Name Print the report Save Report To save the report Finalize Report Click this button if do not want to make further changes in the report To Prepare a Report Select the desired Report Layout from the Layout combo box The report la
24. ewer and also explains the menus available in the CATELLA PACS 5 0 Web Viewer Interface 2 1 Login To log into the software 1 Open the Internet Explorer and type in the default URL Uniform Resource Locator of the CATELLA PACS 5 0 Web Viewer 2 A Login Screen as shown below opens Login Enter the username and the password and click on the Login button Please note The Administrator is the default user with the highest privilege to configure the CATELLA PACS 5 0 Web Viewer Application You can log into the application using any of the user names that the administrator have added using your Server software Refer to the Catella PACS 5 0 Server Manual for details 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 4 TD AMD Technologies Inc Catella 5 0 Web Viewer User Manual 2 2 Main Screen This section gives you the overview of all the key elements available in the CATELLA PACS 5 0 Web Viewer Main Screen shown below Study Date M oO d a it y NFIEM E EM PUE EC EMEN Ee ES View the report of the selected study Load DICOM files to the CATELLA PACS 5 0 Web VIEWER Load DICOMDIR to the CATELLA PACS 5 0 Web VIEWER query server based on customizable search criteria predefined Search Filters aM Review the image corresponding to the selected study Review all the Images and Reports corresponding to the e selected studies Carryout various functionality settings of the application li
25. fault DICOM printer Please note that all the DICOM printers added using the CATELLA PACS 5 0 Web Application will be listed here Refer section 6 1 1 to know how to add a printer Display Scout Lines Enable this option to display the scout lines on the DICOM Image Reset mode after Enabling this option will deselect the annotation tool immediately annotating after the annotation process Display ROI Check this to view the information like perimeter area mean etc of the Region of Interest ROI of the image while using area information for areas measurement option Retain Hounsfield labels on mouse up Selecting this will display the Hounsfield labels on the image Download images as Selecting this will display the representative thumbnails of the thumbnails images Once you have selected the appropriate options click on this Save General Settings button to save the settings Change Password This is used to change the password for the user or Default DICOM Printer 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 29 AMD Technologies Inc Catella 5 0 Web Viewer User Manual 6 1 1 To add a new DICOM Printer 1 Click on the E button in the General settings next to the Default Dicom Printer combo box 2 A DICOM Printer list Dialog opens as shown below DICOM Printer List aS GP e RC TER 1 Click on the aa button in the DICOM Printer Frame of the DICOM Printer List Dialog 2 A DICOM Printer Settin
26. gs Dialog opens DICOM Printer DICOM Printer Settings Device 3 Specify the Application Entity AE Title Hostname Port and Description of the DICOM Printer in the corresponding edit boxes 4 Then select the default orientation destination film size magnification and print layout for the DICOM Printer 6 Select the priority medium and number of copies and click on the OK Button Note The Application Entity Title Hostname Port number Orientation and Film Size fields are mandatory 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 30 rem A D AMD Technologies Inc Catella 5 0 Web Viewer User Manual A Once you have added a new DICOM printer click on the button to check whether the connection with that DICOM printer is successful or not 6 1 2 To edit the DICOM Printer settings 1 Select the DICOM printer that you wish to edit from the list 2 Click on the button in the DICOM Printer Frame of the DICOM Printer List Dialog 3 The DICOM Printer Settings dialog opens Make the necessary changes and click on the OK Button Note The AE Title Name is restricted from editing 6 1 3 To delete the DICOM Printer Select the DICOM printer to be deleted from the displayed list Click on the DICOM Printers Frame A Confirm Dialog opens Click on the OK Button to continue r Delete button in the 6 1 4 To download the images as thumbnails Select the option Download images as Thumbnails in the
27. ialog shown below A dialog displaying all the predefined report templates will be displayed as shown below Application Settings General Modality Annotations Filters Reporting Tremen OOOO T MRI CERVICAL SPINE CT CERVICAL SPINE CT ABDOMEN CT SHOULDER US Abdomen Male US 2 3 Trimester US Early Pregnancy s Header Designer Category List m Eg Det Click on the Add button in the Reporting Dialog shown in the previous page which will be followed by a screen as shown below 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 38 AMD Technologies Inc Catella 5 0 Web Viewer User Manual Report Templates Template cr ABDOMEN Modality CT Category None v Public Font Name Size E ab pote s fe jefe fe le sep e gt S S CT ABDOMEN Formatting Toolbar After a preliminary AP Topogram of abdomen was studied through a series of axial sections of 10 mm thickness from high diaphragm up to the level of symphasis pubis stomach and small bowel were opacified by oral contrast Contrast enhancement was done by injecting 80 cc of angiographin intravenously through pressure injector at the rate of 2 5 ml per second Liver Vertical scan length of liver is 14cms Liver is normal in size and shows normal attenuation values No evidence of any focal mass lesion seen 3 Portal vein and porta hepatis are normal Portal and Hepatic veins are normally enhancing after the contrast
28. ired image in the Image Review Window and right click and choose Mark as Key Image Note Clicking on the Open Key Image button in the Archival Screen lists all the key images that you marked in the Archival Screen 4 1 25 Digital Subtraction Angiography DSA This option helps to apply mask for the Digital Subtraction Angiography DSA images DICOM Avi thereby reducing noise in DSA images without increasing the total dose To do this right click on the DICOM Avi that you have loaded in the Image Review Window and choose DSA A DSA Dialog displaying the selected AVI opens as shown below Click To EN Stop the playing avi Brew Prev Frame View the previous frame of the avi 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 24 c A D AMD Technologies Inc Catella 5 0 Web Viewer User Manual CLA Enable the Apply Mask Option and adjust the slide bar to reduce the noise level in the DSA image BF DSA m 4 1 26 Sync Series This feature of the CATELLA PACS 5 0 Web Viewer Application helps you to review the normal image series and the dark fluid image series corresponding to a patient simultaneously To do this Load the desired normal image series of the selected study to the image viewer window of CATELLA PACS 5 0 Web Viewer Application Then select the appropriate image that you would like to review and click on the button You will notice that the dark fluid image corresponding t
29. isted out in the Series combo box Select the required series The Thumbnails corresponding to the selected series will be displayed in the Thumbnail Display Region as shown below Double click on the image to add the image to the report Finally click on the Save button to save the report End of the Document 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 43
30. ke Password Modality Annotation and Filter Settings 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 5 AMD Technologies Inc Catella 5 0 Web Viewer User Manual Chapter 3 Query and Load DICOM Files CATELLA PACS 5 0 Web Viewer offers you the functionality to query and retrieve the Study details that you want from the default query server based on customizable search criteria 3 1 Query from the DICOM Server To query Study Details using the advanced search option Click on Advanced Search button and specify any one of the search criteria like patient name ID sex modality study date accession and filter in the corresponding fields Then click on the Search button The nearest match retrieved from the default query server assigned for the user will be displayed in the Study Details Display Region as shown below Double clicking the desired study detail will enable you to view the corresponding images and to perform various image review operations Note Use the Clear button to clear all the queried studies The administrator assigns the default query server using the server application zm referen A ren Bit Compass iles Dicom Dir PatientID First Name Age Sex Study Date Study Desc MOD Reporting Accession 4 Images p 130620081718 15 Enter study MR PENDING 1 i 141020081603 sadf lt Enter study SC PENDING 4 120620081136 dsfds lt Ente
31. lick the desired study from the queried list of studies or select the desired study and click Open Study Button An Image Review Screen opens displaying the images in the default series layout Refer General Settings to set the default series layout 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 9 AMD Technologies Inc Catella 5 0 Web Viewer User Manual 1c a AIS ODE 4 JO m ow 2e ds i 6 ula ui I mn n Rl Now to carryout various annotations on the image double click on the desired frame of the image series and make the annotations on the image using the annotation toolbar Please note The annotation tools of the Image Review Screen are enabled only on selecting the image The following table gives a quick overview of all the annotation tools available in CATELLA PACS 5 0 Web Viewer Icon Option ClickTo Edit Options Get the mouse pointer or to deselect the selected annotation tool Rotate Left Rotate the image to the left Rotate Right Rotate the image to the right Flip Horizontally Flip the image horizontally Flip Vertically Flip the image vertically Reset Reset the annotations zoom pan rotate and flip operations performed on the image Display Options OD Window Leveling View the window width and level 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 10 em A D AMD Technologies Inc SCE Invert View negatives of the image Hounsfi
32. line A Set Properties dialog as shown below will open Set Properties Lett 2T Top 100 m Heicht FE Line Color Line Width Line Style Solid Line Specify the left X and top Y positions width and height of the measurement line and then select the line color and line style Finally click OK 4 1 21 Area Measurements The Area Measurement Functionality of the CATELLA PACS 5 0 Web Viewer Software helps you to measure the area perimeter mean min max and standard deviation of the required Region Of Interest ROI ry To do this click gt button in the Image Review Window and drag the mouse to define a square or rectangle of the required size You will notice a rectangle with all angular measurement values like area perimeter ROI mean etc displayed on the image as shown below Please note the ROI details will be displayed on the image only if the Display ROI Information for Areas Option in the General I Settings Dialog is enabled Refer General Settings in page 39 to enable this option 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 21 AMD Technologies Inc Catella 5 0 Web Viewer User Manual Active Jutmage viewers Pret composes cow Reporng sss NN ENE SUE FT ker na amp D 3A4 d Note The measurement details will appear in the default color and font Refer Annotation settings in 48 to set the default measurement settings To change the default line and fi
33. ll color settings and the location of the measurement Area double click the measurement rectangle A Set Properties dialog as shown below will open Set Properties Lett 33 Top 5A Nas MELLE Line Color Line Width Line Style Transparent Fill Calei Fill Style Specify the left X and top Y positions width and height of the measurement rectangle Then select the line color line width and line style and also the fill color and fill style of the rectangle Check the Transparent Box if you wish the image to see through the background color of the measurement rectangle 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 22 AMD Technologies Inc Catella 5 0 Web Viewer User Manual Finally click OK 4 1 22 Angular Measurements The Angular Measurement Functionality of the CATELLA PACS 5 0 Web Viewer Software helps you to measure the angle between different points of the image Please note only the angle between 0 180 degrees can be measured To do this click A button in the Image Review Window or right click on the image and select Mode gt Angular Measurement Drag the mouse on the image to define a base line and then click at the end of the base line and drag the mouse to a desired point You will notice the angle defined between the two lines being displayed on the image as shown below Print Composer L CD Writer Reporting GDE d nt a OS e al B gt xi a i Q d a B ea ibi Od
34. n the _ Predefined Filters bytton You will notice that all the filters that you have defined using the Filter Settings will be listed out as shown in the figure given below Refer the Filter Settings on page 44 to define edit or delete a search filter 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 6 A AMD Technologies Inc Catella 5 0 Web Viewer User Manual M Now click on the desired filter name All the study details matching the selected filter criteria will be displayed on your screen FUJIDOOD1 TANAKA HANAKO um OVCHESI Satish 00000017198 Mr KRISHNAN 45y s D SR FENDI Rumm T R ORBED 003 RcLAAMGD cT REFORTED ec O coro 0 y o ma mam mS Ww 5o oaea mv VOGLER a7 osr NNI Hg NE HS LEN Ug Seca a a EE CE Le ae i COSE HE HER LN UNE 2003 Monday May 26 2003 FINALIZED Bl CT AORTA RUNOFF FINALIZED DORTRCTM 76893476 d nnn ASKN IRMN 08v cr Paez 9 2008 UpperExtemiies CR PENDING LEFT SHOULDER CR PENDING 022 30 2008 Enter study description CT PENDING 76893476 LNC NNNM MN SURIYA SIVAKUMAR 520081030 EDGE web test Pg R i H H i H F H i H F dvanced Se 3 2 Load DICOM File If you wish to review the image corresponding to a specific study you can load that DICOM File onto the CATELLA PACS 5 0 Web Viewer by clicking on the button in your CATELLA Archival Screen Next an O
35. ng to the selected studies in advance thereby reducing the time taken to load the images during the image review process To do this select the studies whose image you wish to download from the Archival Screen and right click and choose Download from the Pop up A Downloads Dialog opens as shown below Downloads Pirau 1 3 12 2 1107 5 1 4 50051 4 0 16 atlsrvr 113 341 Lerlac 1 312 2 1107 5 1 4 50051 4 0 16 atlsrvr 0 288 DAVID RAJU 78 Y 7M 1 2 825 0 1 36580043 6 4915 207 atlsrvr 0 8 DR PMV SUNDARAM 1 31221107 5 2 10 17430 5 0 1 atlsrvr 0 61 PRAKASH KUMAR 42 1 312 2 1107 5 1 2 11291 20070 atlsrvr 0 101 DAVID RAJU 78 Y 7M 1 2 826 0 1 3680043 6 6927 100 atlsrvr 0 14 DAVID RAJU 78 Y 7M 1 312 2 1107 5 1 2 11291 20070 atlsrvr 0 86 1048 2007 AMARESH 15Y M 11 1 312 2 1107 5 1 2 11291 20070 atlsrvr 0 1 Use the Move UP and Move Down buttons to increase or decrease the process priority of the selected study Clicking on the Pause button pauses the download process Click on the Hide button to hide the Download Window Right clicking the Study list Area of the Archival Screen and selecting View Downloads helps you to view the download window Chapter 4 Image Viewer CATELLA PACS 5 0 Web Viewer enables you to perform various annotations markups on the image using the annotation tools This chapter describes the annotation tools and how to use them 4 1 Image Viewer Overview To annotate the image 1 Double c
36. o the selected normal image being displayed on the image review window as shown below Note Choose the image series layout as 2x2 d DESERT Archive Image Viewer Print Composer at head general 26 Apr 04 X w Q o i A 5 PH Oo a ry gt rm localizer MR 2 Ise rst tra CV TIMB S14 b4 4 Do Js e b G dah n i 12 tirm tra dark fluid Cv 1 MR t se tra CV 1 MR t se sag CV 1 MR 12 tirm cor dark fluid Cv 1 MR t1 se sag CV 2 MR tof fi3d tra 5 slab KRI SR MR lt MIP Collection MIP Range Cv 1 MR Report x erto 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 25 SEE EE A D AMD Technologies Inc Catella 5 0 Web Viewer User Manual BILLS Chapter 5 Print Composer CATELLA PACS 5 0 Web Viewer offers you the functionality to print all the selected images in the desired print layout using a DICOM printer or any other network printer 5 1 Print Composer Overview To print the selected images Click on the Print Composer tab in the main screen The images of the selected study that you have added using the Send to Print Composer option in the Image Review Screen will appear on the Print Composer Window will be displayed in the default print layout as shown below Refer page 25 for sending images to the Print Composer A DEERE Archive Image Viewer Print Composer Preferences Select Printer one v IOG LAR S
37. oc 340 3 503 Rev 01 A D AMD Technologies Inc Catella 5 0 Web Viewer User Manual SS Ortype inthe field Patient ID Specify patient ID Note To get the details of all patients leave the field blank or type in the field Select the patient s sex Modality Choose the modality Study date span Select study date span as today yesterday last week or last month Specify the accession number Lists the default query source for the filter Set as default Select this checkbox to set the filter as a default filter To edit Filter 1 Select the desired Filter name from listed filter names 2 Click Edit button in the Filter Settings Dialog 3 A Search Filter Dialog opens 4 Make the necessary changes and click on the OK Button The Filter name is restricted from editing To delete Filter 1 Select the desired Filter name from the list 2 Click on the Del button in the Filter Settings Dialog 3 A Confirm Dialog opens Click on the OK Button to continue 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 36 AMD Technologies Inc Catella 5 0 Web Viewer User Manual Chapter 7 Report Designer The chapter gives you a detailed description on how to design a Report Header and Report Templates for various studies how to carry out report settings and how to prepare a report for the selected study 7 1 Categorize Report Templates This option of the CATELLA PACS 5 0 Web Viewer Applicati
38. oc 340 3 503 Rev 01 Page 14 m A D AMD Technologies Inc Catella 5 0 Web Viewer User Manual SS Right click the Image Review Region and select Mode gt Rectangle from the Pop Up Or Click R key in the keyboard 2 Left click and drag the mouse to define a rectangle Draw a circle or ellipse on O the image 1 Click button Of Right click the Image Review Region and select Mode gt Ellipse from the Pop Up Of Click E key in the keyboard 2 Left click and drag the mouse to define a circle or ellipse Draw a freehand line or shape 1 Click 4 button 2 Left click and drag the mouse to define a freehand shape Note To delete a specific annotation line arrow rectangle circle or text box that you have marked on the image select the required one and press Delete Key in the keyboard To delete all the annotations marked on the image right click and select Delete All Annotations All the annotations line arrow circle and rectangle will appear in default line and fill settings To change the default line and fill settings and to change the location and size of the image double click the annotation A Properties Dialog as shown below will open Specify the new location and size of the annotation Then change the required parameters like line color line width line style fill color and fill style Click on the OK button to save the settings Notes To allow images to show through the backg
39. on helps you to categorize the report templates To do this Click on the Preferences button in the CATELLA PACS 5 0 Web Viewer Screen and choose the Reporting Tab in the Application Settings dialog An Application Setting Dialog displaying all the predefined report templates opens Application Settings General Modality Annotations Filters Reporting Template Name MRI CERVICAL SPINE CERVICAL SPINE ABDOMEN SHOULDER Abdomen Male 2 3 Trimester Early Pregnancy Nj Header Designer Category List jada ES Det Now to add a new report template category click on the Category List button in the Application Settings dialog A Category List Dialog as shown below opens Category List E Category Name General Abdomen 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 37 AMD Technologies Inc Catella 5 0 Web Viewer User Manual Click on the Add button in the Category List Dialog and enter the category name in the dialog shown below To edit the category name select the required name from the Category List Dialog and make the required changes in the category name Pacswebviewer Category M ame enera Clicking on the Delete button deletes the selected category name from the list 7 2 Design Report Template To design a new report template Click on the Preferences button in the CATELLA PACS 5 0 Web Viewer Screen and choose the Reporting Tab in the Application Settings D
40. pen Dialog pops up on your screen Locate the DICOM file that you wish to load and click on the OK button per 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 7 AMD Technologies Inc Catella 5 0 Web Viewer User Manual The selected file will open in the Image Viewer Window as shown below Double click on the image and carry out various annotations using the available annotation tools Refer image review section in page 15 for details nage Views ereerences LU AJG cp E 4 xam ORs c g DO NADBOLAH BAD 3 3 Load DICOMDIR To load a DICOMDIR to the CATELLA PACS 5 0 Web Viewer Application click on the button and select the DICOMDIR File which you would like to load from an Open Dialog as shown below Lek pri G Desktop E my Documents E biy Computer id my Network Places r images Di Sangeeths F DICOMDIR File name DICOMDIR z Filet of ippa DICOMDIR Files 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 8 a A D AMD Technologies Inc Catella 5 0 Web Viewer User Manual ES You will notice that all the images corresponding to the selected DICOMDIR will be displayed on your Image Viewer Window To mark annotations on the image double click on the required image and mark annotations using the annotation toolbar and Pop Up Options 3 4 Download Studies This option of the CATELLA PACS 5 0 Web Viewer helps you to download all the images correspondi
41. r study SC PENDING 5 amm rer Dene 0000001719 Mr KRISHHAH 45Yrs M 642001 CT PENDING 100 02195 MJEEVARATHIHAM 055V F 7 15 2002 REHALA ANGIO CT PENDING 44 10482007 AMARESH 16Y M 2122 M 4242007 PLAN CT PENDING 12 5560 07 VEHKATESH S 32Y M M 5 02007 CHEST CR PENDING 20070510133501 Lrodofncd Diera 5740 07 SABANNA 55Y M M 54102007 CHEST CR PENDING 200705101515 cla samen 5707 07 RAVAHAMMA 35Y F F 5 11 2007 CHEST CR PENDING 200705111216 5793107 SUBBAIAH 65Y M M 5 112007 SPINE CR PENDING 200705111309 ID HO BH 392 DEVAI23Y F F 5 11 2007 CHEST CR PENDING 200705111129 IDHO 2303 SIHCHAHA 9 MONTHIF F 5 11 2007 CHEST CR PENDING 200705111214 IDHO 2297 B O MAHALAKSHMI F 5 11 2007 CHEST CR PENDING 200705111209 E 5760 07 GANGAMMA 48Y F F 5 11 2007 CHEST CR PENDING 200705111317 irs 2717 2003 ID HO BH 376 KRISHNAILP 61M M 5 112007 CHEST CR PENDING 200705110937 E IDNO 752 CHANDRA 45Y F F 5 11 2007 SPINE CR PENDING 2007051113061 j 2 17 2005 w HO 2308 AMEEN SHAREEF 4Y M M 541 2007 Lower Extremities CR PENDING 200705111332 Mte aaee D HO 2313 RAVI KUMAR 13Y M M 5112007 CHEST CR PENDING 200705111539 M 9538 06 BHAGYAMMA 32Y F F 5 11 2007 CHEST CR PENDING 200705111120 5785 07 BASAVA HAYAKA M 5 112007 CHEST CR PENDING 200705111548 1 n 4 b o OCE Series Description MOD SeriesDate Series Time Series UID Clear _ No data to display gt To query the study details based on predefined filters Click o
42. round color of the annotation circle ellipse rectangle square and text box select the Fill Style option in the Set Properties dialog as Clear Refer to Annotation Settings for the default properties of the line arrow rectangle and ellipse drawn on the image 4 1 8 Include text on the image To include text on the image 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 15 AMD Technologies Inc Catella 5 0 Web Viewer User Manual 1 Click I button or Right click the Image Review Region and select Mode gt Text option from the Pop Up Or Click the T key in the keyboard 2 Left click and drag the mouse from the desired point of start and end to define a text box of the desired size You can move the text box to a desired position with the mouse if necessary or you can change the size of the text box using one of grab tabs around the edge Type the text in the text box and click the Enter Key or click the mouse pointer anywhere outside the text box 3 You will notice that the text will appear in the default font settings To change the font settings of the text and the location and size of the text box double click on the text box Refer to Annotation Settings to change the default font settings of the text tool 4 A Properties dialog as shown below will open Specify the new location and size of the text box Set Properties Eg Left m Top j2 Width mo Height ps Transparent Fill Coen rill St
43. sets sees nnne nnne nnne nnns 24 4 1 24 Mark Key MAGS savesiseenisvascvkar isti mtv std vag pss 3d pida dd aw SR dnas dw AR D bl e UR viva P Enc dvd 24 4 1 25 Digital Subtraction Angiography DSA cccccccccecceseeeeeeeseeeeeeeeesaeeseeeeesaeeeeeesssaaeeeeeessaaeeeees 24 As ict Ost ING Ie ISS E E A EA E E E E E A A E N E 25 Chaple 5 FHD CGOMPO SOP M M 26 5 1 Print Composer Overview s ssssnnsssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nnmnnn nnmnnn mnnn 26 Chapter 6 Preference Settings crccisc ica a reas its seo eee a mae eu a eae a race neeeeeavane eee 29 Sm BR GON ead ella po CN ERE DOE 29 6 1 1 To add a new DICOM Printer eeeeeeesssssssseeeseeeeeeeennnnnn nennen nnne nnn nnn nnns nnn 30 6 1 2 To edit the DICOM Printer settings ssseseeesseesseeeeeeneennnnnennnnnnnn nnne nnne 31 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 2 A D AMD Technologies Inc Catella 5 0 Web Viewer User Manual Sst 6 1 3 To delete the DICOM PYInter ccccccccsseseeccceeeeeceeeeeeeeeeeeeseeeseseeeeeeeeeseeeeeeeeeeessseaaaeeeeeeeeseaaas 31 6 1 4 To download the images as thumbnails ccseeccceeeeseeeeeeeeeaeeeeeeeeseeeeeeeessaeaeeesessaaeeeesssaaees 31 6 2 Tao 2 ol SENINGS TEE CET ETE 32 6 2 1 How to Add Edit Delete Presets cccccccscccccececseeeeeeeecaeeeeeeeeeeeeseeeeeseeeeeeeessaaaeeeeess
44. to Line Style To select the line style To make the fill color transparent Fill color To set the fill color for the rectangle and ellipse drawn on the image To set the fill style for the rectangle and ellipse drawn on the image Fill Style Note To allow the images to see through the background of the annotation set the fill style as Clear To set the default font for the text included on the image E ed To set the font for the measurement tool Apply To Save the settings 6 4 Filter Settings This functionality enables you to carry out the search filter settings On clicking the Filter Tab in the Application Settings Dialog the options to add edit and delete the search filters will appear in the Application Settings Dialog as shown below 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 34 AMD Technologies Inc Catella 5 0 Web Viewer User Manual Application Settings m Erit Hz Filter M ame Patient Mame a Study Description To Add Search Filter Settings On clicking the button in the Filter Settings Dialog a Search Filter Dialog as shown below opens Specify the filter name and other required details and click on the OK button Filters The table below gives a quick overview of the fields in the Search Filter dialog Fils A A Descriptions Note To get the details of all patients leave the field blank Page 35 2010 AMD Technologies Inc D
45. yle Then click the Set Font Tab in the Properties dialog which will be followed by a Font Dialog as shown below Change the font name style size and color if required and click on the OK button 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 16 Catella 5 0 Web Viewer User Manual Aral Black O Arial Narrow Book Antiqua Bookman Old Style Century Gothic O Comic Sans M5 Effects Sample Strikeout underline Color ET white kd Script Westem 4 1 9 Adjust the Display Parameters of the image This option of the CATELLA PACS 5 0 Web Viewer helps you to change the display parameters such as the sharpness window width and level and the enhancement values of the image To do this click the ry button in the Image Review window or right click and select Processing gt Adjust Image from the Pop Up An Adjust Image Dialog as shown below will pop up on your screen as shown below Next change the required parameters and click ok Adjust Image i i 9 4 1 10 Display Hide Overlays on the image To display hide overlays like measurement scales values etc on the image Click D button Of Right click on the Image and select Processing gt Display Overlays from the Pop Up 4 1 11 Change Image per page To increase the number of images displayed per page 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 17 AMD Technologies Inc Catella 5 0 Web Viewer User
46. your system If you close CATELLA PACS 5 0 Web Viewer before saving the PowerPoint presentation then PowerPoint will be closed automatically 4 1 16 Select All Images This option is used to select all the images to add the images to the print composer window to create avi and to send the images to the remote DICOM node 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 19 AMD Technologies Inc Catella 5 0 Web Viewer User Manual To select all the images displayed in your Image Review Window Right click on the image and choose Select All or press Ctrl A keys in the keyboard Note To select random images press Ctrl key and select desired images using the mouse 4 1 17 Create AVI file This option allows you to create an avi file by merging the selected image series To do this right click the image and select Create AVI File from Series option A Save As Dialog opens Enter the file name and click ok Then a Video Compression dialog as shown below will open Select the compression type and click OK Video Compression Compressor E Kev Frame Every E fames Data Rate 0 KB sec Note 1 The avi can be created only when the images are of the same size 2 The file size and quality of the avi depends on the compression selected The Microsoft MPEG 4 Video Codec is the recommended compression type 4 1 18 Send Image to Remote Node This option enables you to send all the selected images to the s
47. youts available are Report only Report with images at side and top and only images 1 2 4 6 per page The report layout including the predefined Report Header will be displayed in the Reporting Area as shown below AC DEREN m D a Archive Image Viewer Print Composer Preferences t1 se COR CV 1 Images At Top Lo Save Report Finalize Report f prn eum ps Font Name i Patient Name DR P V SUNDARAM 69 M Patient ID 2411 Study Date 08 May 04 Study Description head general _ ill Lith i Reporting Hotes alignment of cervical spin is normal I Refer Design Report Header on page 50 for details The Predefined Report Templates corresponding to the selected study will be listed out in the Template combo box Select the appropriate report template The contents corresponding to the selected template will be listed out in the Reporting Area Make the required changes in the report using the formatting toolbar Note The font size available in the Reporting Region does not correspond to other windows applications Here 128 pt 2 10 pt 3 12 pt 4 14 pt 5 18 pt 6224 pt 7 36 pt 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 42 me A D AMD Technologies Inc Catella 5 0 Web Viewer User Manual S Refer Design Report Template for details The image series available for the selected patient will be l

Download Pdf Manuals

image

Related Search

Related Contents

H113-8-2009  Kensington Pocket KeyPad Calculator  Hotpoint VTD 6000 Clothes Dryer User Manual  Manual de usuario Primera Sesión Sistema “Consejos Escolares de  Scosche tuneFREQ RDS  Rubbermaid Commercial Products FG9T5800BLA Instructions / Assembly  Garland 2000 User's Manual  Whirlpool RF3305XX User's Manual  PF7S USER MANUAL  User Manual: JCI 140 Static Monitor  