Home
MAnuAL CrAnE SCALE OCS
Contents
1. Rear four digit of current accumulated value L Front four digit of current accumulated value O Return to weight ATTENTION 1 Press TARE ZERO query weight and accumulated value 2 press MR return CLEAR OPERATION ILLUSTRATION CLEAR CLr Confirm accumulation clearance CLEAR noCLr Cancel accumulation clearance ZERO DISPLAY MR ZERO Display current zero value OVERLOAD QUERY MR CLEAR Display overloading times VOLTAGE DISPLAY MR F1 Display battery voltage POWER OFF OPERATION ILLUSTRATION LORE Display battery voltage and power off www vetek com e info vetek com
2. 1t 600 OCS 2t 600 80 ji i OCS 3t 730 100 55 28 OCS 5t 850 120 70 48 OCS 10t 850 130 70 64 OCS 15t 900 140 70 68 www vetek com e info vetek com VETEK O user manual OPERATION GUIDE TURNING ON Press button OFF ON on the scale display as below sequence 88888 display self testing 3000 max capacity U6 30 current battery voltage waiting stable signal 0 STB lights up ready for operation ZERO Press button ZERO on the scale or press key 0 on the controller TARERING Press button TARE on the scale or press key 0 on the controller WEIGHT HOLDING Tryck in knappen HOLD p fj rrkontrollen LOW POWER WARNING If the voltage is less than 5 8V the display will flash until indicate LB and power off automatically in 1 minute The battery recharging is needed OVERLOADING WARNING When weight more than 100 F S 9e the display indicate OL Removing object is necessary POWER SAVING When no weight changed shows up until weights changed or power off in 60 minutes RECHARGING BATTERY 1 Turn off the scale Connect the adaptor to AC power supply and plug the connector into the socket in the rear of scale When the indicator turns from green to red charging is over 2 If the scale needs to work non stop take off the dead battery and replace it with a full one Recharging the dead battery separately ATTENTION Normally re
3. L VETEK user manual MANUAL CRANE SCALE OCS Models OCS A OCS Band OCS C Before using please carefully read this usage manual MODEL A B MODEL G CONTENTS The safety guides Product features Product specification Electronic diagram Structure and dimension Operation guide Display illustration Warnings Trouble shooting Remote controller guide NN OOO FR WWD D Box 79 Industrivagen 3 Tel 46 0 176 208920 Web www vetek com REVISED 1 Scandinavia s largest webshop for scales 760 40 Vaddo Sweden Fax 46 0 176 208929 Email info vetek com 03 2010 VETEK G user manual Before using please carefully read this usage manual THE SAFETY GUIDES Please read through the following instruction and advice before using crane scale e Overloading is harshly prohibited e Long time loading will decrease the accuracy and shorten the life of the scale Before using please check the battery voltage and recharge in time e Before using please check the safety between hook shackle and junction parts Do not try to repair the crane scale by yourself e Use dedicated charger only PRODUCT FEATURES Excellent Quality Strictly in accordance with OIML R76 and European directives High Safety Aluminum casting case highly firmed hook and shackle special load cell for safety installation Strong Reliability High quality components on PCB to insure long time stability Broad Applicability 56mm high
4. ble Check and replace load cell Keep the scale in dry environment Wait 3 5 minutes after powering on Scale should be hung up Make the hook flexible against off axis loading Replace battery Replace the connector Check and clean it Replace controller battery BRIGHTNESS OPTION F1 O 5 levels O no display 1 Min bright 5 Max bright Default 3 ZERO ZERO Set O when empty load HOLD OPERATION ILLUSTRATION HOLD TARE 1 TARE DIRECTLY Hold the weight HOLD lights on Press it again to resume OPERATION ILLUSTRATION TARE 2 SET TARE TARE light on display net weight Press it again to return gross weight OPERATION ILLUSTRATION Display current tare value MR TARE M TARE ZERO CLEAR MR Modify tare value Input the tare value Exit TARE light on Display weight without tare upon weighing www vetek com e info vetek com L VETEK user manual ACCUMULATION 1 ACCUMULATION OPERATION ILLUSTRATION M No Current accumulation times H High 4 digits of current accumulated value L Low 4 digits of current accumulated value ATTENTION f Accumulation value will display twice before the scale return to weigh mod automatically Or press MR to return directly 2 Total accumulation H xxxx L xxxx E g H2244 L5566 22445566 3 Query OPERATION ILLUSTRATION MR M No Current accumulation times Current weight H
5. character display 30m distance in sight widely used in storage industry textile industry metallurgy industry etc Simply Operation Automatic low battery check electricity energy saving power off and overloading alarming wireless remote controller and dedicated charger Complete function Kg Lb conversion hold tare division option stability regulation accumulation query gross net weight remote power off etc www vetek com e info vetek com VETEK O user manual PRODUCT SPECIFICATIONS Accuracy Class Similar to OIML III Division NO 3000 Display 56mm 5 digits LED LCD Zero Range 4 F S Tare Range 100 F S Stable Reading Time lt 10S Overload Indication 100 F S 9e Safety Load 125 F S Ultimate Load AOO F S Battery Life 250 hours Power 6V 10Ah rechargeable sealed acid lead batteries 150 x 50 x 90 mm Battery Charger DC9OV 1 5A Remote Controlling Distance gt 10m Batteries of Remote Controller AAA Batteries x 2pcs Operation Temperature 10 C 40 C Operation Humidity ELECTRONIC DIAGRAM lt 90 RH under 20 C Infrared control Control key Load cell i Amplifier Display www vetek com e info vetek com L VETEK user manual STRUCTURE AND DIMENSION OCS A B OCS 0 5t 420 OCs 1t 420 65 35 12 OCs 2t 420 65 35 12 OCS 3t 600 80 45 14 OCS 5t 730 100 55 24 OCS 10t 850 120 70 44 OCS 15t 900 140 70 60 OCs 20t 900 140 70 60 OCS G FOR STEEL INDUSTRY OCS
6. charging time should not exceed 8 hours However long time charging will not damage the battery TURNING OFF Press key OFF ON on the scale for 3 seconds or press OFF on the controller for 3 seconds display as below sequence U6 30 current battery voltage OFF display 2 seconds before power off ATTENTION When no weight changed it power off in 60 minutes automatically www vetek com e info vetek com L VETEK user manual DISPLAY ILLUSTRATION Err10 Err41 Err42 Erri3 CLr noCLr 88888 noACC SHIFt U6 30 SCALE SEtUP UAdJ OL Lb Lo End OFF WARNINGS Waiting stable signal Accumulated weight doesn t exceed Min Capacity Accumulated times exceed 30times Accumulated weight exceed 99999 Accumulated repeated multi accumulation is not allowed Confirm accumulation clearance Cancel accumulation clearance Confirm accumulation deletion No accumulation Switch to other mode Battery voltage Calibration Parameter setting Battery adjustment Overload warning Power saving mode Batterisparlage End Power off 1 For good performance and precise measurement be careful with daily operation and maintenance 2 Rotate the loading object rather than the scale if needed 3 Don t use the scale under thunder or rain 4 Check the clips pins and screws regularly 5 When battery is out of power or battery indicator
7. turns red check the battery and replace it with a full one 6 When scale is disengaged hang it on special shelf in dry and well ventilated room Put the scale on the ground is not suggested www vetek com e info vetek com VETEK G user manual TROUBLE SHOOTING No display when power on No display when power on Display flashes Can not turn on off Can not zero Can not tare Recharging indicator does not light Recharging indicator does not light Unstable display Unstable display Unstable display The display doesn t show O when nothing is loaded The display doesn t show O when nothing is loaded Weighing value in big error Battery can not recharge Battery can not recharge Short remote distance Short remote distance Battery is damaged Battery is not connected Low battery power OFF ON button damaged ZERO button damaged TARE button damaged Defective adaptor The adaptor isn t connected well The load is in motion Overloaded or defective loadcell Scale is damp Load cell is not ready to work Improper placement of scale Improper operation Defective battery Defective recharge connector Receiver is too dirty Low battery power of controller REMOTE CONTROLLER GUIDE Check battery Reconnect the battery Recharge the battery Check amp clean the button Check amp clean the button Check amp clean the button Check the adaptor Check the plug Keep the load object sta
Download Pdf Manuals
Related Search
Related Contents
Ligne - Haute PEGASUS Software User Manual : Module MFILERUNNER Samsung Barra de Sonido ASUS G20AJ User's Manual ) クロ一ラクレ一ン 二アラインマスク』空気仕縮装置 取扱説明書 English (US) User Manual Add-On Computer Peripherals (ACP) FTLX8541F2-AO network transceiver module HABILETÉS SOCIALES ET THEORIE DE L`ESPRIT Copyright © All rights reserved.
Failed to retrieve file