Home
instructions for use and maintenance
Contents
1. 12 2 2 Cleaning the brazier Periodically with a frequency ranging from one to three days depending on the operating hours of the boiler remove the ash that is deposited inside the brazier Fig 12 1 This has the purpose of ensuring free flow of combustion air through the holes inthe BURN POT Fig 12 1 12 2 3 Cleaning the ash bin The ash bin should be cleaned every week or whenever necessary To access the ash bin open the door and remove the bin Fig 12 2 Empty the bin into a special metal ash collection container Vacuum any residual ash from the compartment that houses the ash bin Reposition the ash bin Close the doors Lift remove the burn pot and clean the surfaces and the compartments inside the burn pot Fig 12 3 Fig 12 2 Fig 12 3 cod 004772540 05 2013 Palazzetti PN Italy 53 134 PALAZZET TI USE AND amp MAINTENANCE 12 2 4 Cleaning the flue gas compartment The flue gas compartment should be cleaned fortnightly or whenever necessary Take out the lever for moving the turbulators and removing the soot Fig 12 5 Insert this into the special notch
2. The boiler will turn off also in case the water temperature continues to rise despite the modulation In this case the boiler will turn on only if the temperature difference between the value you set up and the real one is higher than 20 C In this configuration it is therefore recommended to regulate a high water temperature ex 70 C CONFIGURATION 2 Set this configuration to switch the boiler on or off manually or by timer when the boiler is connected directly to the central heating radiators The boiler will modulate output according to the room temperature read by the probe on the boiler The Eco mode function can be used to have the boiler switch off or on based on the set room temperature The frost protection function can also be set in this configuration CONFIGURATION 3 Set this configuration when wanting to connect the boiler to a storage tank with coil The boiler will be controlled switch on and off based on the temperature read by the probe in the storage tank The frost protection function can also be set in this configuration CONFIGURATION 4 Set this configuration when wanting to connect the boiler to a storage tank without coil The boiler will switch on based on the temperature read by the probe in the storage tank and will switch off based on the boiler return temperature The frost protection function can also be set in this configuration CS Some typical installation diagrams are shown on th
3. If information is requested from the manufacturer of the product always refer to the serial number and other identifying data shown on the product s identification label Special maintenance Special maintenance operations must be carried out by qualified personnel who are authorised to work on the model of boiler that this manual refers to Responsibility for installation PALAZZETTI accepts no responsibility for the work carried out to install the producy such responsibility lies with the installer who is required to carry out checks on the flue and air intake and ensure installation is completed correctly Furthermore all safety standards required by relevant legislation in force in the country where the boiler is installed must be complied with Use The boiler must only be used in compliance with the instructions provided in this manual as well as with all safety standards required by relevant legislation in force in the country where the boiler is installed cod 004772540 05 2013 Palazzetti PN Italy 1 7 1 8 1 9 INTRODUCTION MAIN REFERENCE STANDARDS A Directive 2006 95 EC Electrical equipment designed for use within certain voltage limits B Machinery Directive 2006 42 EC C Directive 2004 108 EC Approximation of the laws of the Member States relating to electromagnetic compatibility D Directive 89 391 EEC Introduction of measures to encourage improvements in the safety and he
4. 10 5 RESTARTING AFTER A POWER FAILURE In the event of power failures the stove will switch back on automatically checking the safety conditions when power returns 10 6 LOCK KEYPAD FUNCTION This function is used to disable the use of the control panel and avoid accidental modifications To enable disable the function a Use the arrow buttons 9 to go to the setup menu X and then press b Use the button to select the password 7 and then press lt to confirm c Select submenu 10 and confirm by pressing d Use the buttons to set one of the following values OFF Lock keypad disabled Lo Only the on off button d is enabled HI Lock keypad enabled e Press L to confirm the settings 50 134 cod 004772540 05 2013 Palazzetti PN Italy USE AND amp MAINTENANCE PALAZZETTI 10 7 FROST PROTECTION FUNCTION In configurations 2 3 and 4 a minimum temperature can be set below which the boiler will switch on outside of the set time bands Configuration 2 To set the frost protection temperature a Use the arrow buttons 9 D to go to the setup menu Yl and then press 4 b Use the button to select the password 7 and then press to confirm c Select submenu L 9 and confirm by pressing d The value will flash change it using the buttons OFF 3 20 C e Press to confirm the settings Configuration 3 and 4 To set the frost p
5. FLUE GAS EXHAUST The boiler is equipped with exhaust fan The boiler operates with negative pressure in the combustion chamber and consequently the flue gas discharge must be airtight The boiler must be connected to its own separate flue gas exhaust system capable of ensuring adequate atmospheric dispersion of the combustion byproducts The components making up the flue gas exhaust system must be suitable for the specific operating conditions and bear the CE mark The pipes used to discharge the flue gas must have a nominal diameter of 10 cm Fig 5 5 The flues should be suitably insulated e g using rock wool or made using double wall steel pipes except for the initial vertical section inside the room An initial vertical section measuring a minimum of 1 5 metres is required to ensure correct flue gas exhaust For the flue dimensioning use OPa There should be at least three changes in direction along the flue in addition to the flue connection at the rear of the boiler using 45 angle connectors Use always a T connector with inspection cap on all horizontal or vertical changes in flue direction It is necessary to connect a pipe at the bottom of the T junction in order to discharge the smoke condensate that could form in the flue gas exhaust Fig 5 6 The maximum length of horizontal sections is 2 3 m with an upwards slope of 3 5 Fig 5 5 Anchor the flues to the wall using special collars T
6. or mental abilities or without sufficient experience or knowledge unless they are supervised or instructed on the use of the appliance by a person responsible for their safety The intended use of the boiler described above and the configurations available are the only ones permitted by the manufacturer never use the boiler in any way not described in the instructions provided 32 134 1 3 1 4 1 5 1 6 INTRODUCTION a 4 i PURPOSE AND CONTENTS OF THIS MANUAL The purpose of this manual is to provide the fundamental and essential rules for correct installation maintenance and use of the product Carefully following these rules will ensure a high level of boiler safety and productivity HOW TO KEEP THIS MANUAL Storage and reference This manual must be kept with care and must be always available for reference by the user and by assembly and maintenance personnel The installation manual is an integral part of the boiler Damage or loss If required an additional copy can be ordered from PALAZZETTI Sale of the boiler If the boiler is sold the user must also provide the new owner this manual UPDATES TO THE MANUAL This manual represents the state of the art at the time the boiler was introduced onto the market GENERAL INFORMATION The information given in this manual apply as a general rule any Community legislation national or municipal must still be complied with Requesting information
7. 2 ii Setup Is the number of degrees centigrade below the switch 05 5056 8 Restart delta off temperature at which the stove switches on again 0 7 40 C automatically except in configuration 1 ds 9 Frost protection Minimum temperature below which the stove switches on OFF 3 20 C temperature except in configuration 1 OFF 3 50 C HU Lock keypad Disables the buttons on the keypad OFF Lo Hi 11 Display brightness Sets display brightness OFF 13 5 ie J Display mode Sets how the data is displayed OFF 1 4 1331 Buzzer volume Sets the buzzer volume OFF 1 5 14 Type of pellets Three different types of pellet can be set 1 3 Allows the activation of the manual loading from the 115 External tank external tank optional 30 Installer menu Sets displays the stove configuration PWD 54 40 Service menu Menu reserved for the service centre Submenus 301 and u in the Setup menu are password protected and reserved for service centre personnel 7 2 USING THE CONTROL PANEL The arrow buttons 3 are used to scroll between the different menus that are highlighted e When selecting a given function simply press the button and then modify the values again using the buttons e Pressing the button confirms the setting e In general all values that are flashing can be modified using the buttons The cancel button is used to cancel any changes pressing and holding
8. I s I Termostato exterior i I I I I I I I I I I I I I I I I I I I I I I I I I I I I dS omponenti compresi nella stufa omponents included in the stove omponenten enthalten in den Ofen omposants prevus dans le po le iezas incluidas en el kit estufa Sonda temperatura ambiente Room probe Raumtemperatur Fuehler Sonde temp rature ambiante Sonda temperatura ambiental Componenti compresi nella stufa Components included in the stove Komponenten enthalten in den Ofen Composants prevus dans le po le Piezas incluidas en el kit estufa 134 136 cod 004772540 05 2013 Palazzetti PN Italy PALAZZET TI CONFIGURAZIONE 3 CONFIGURATION 3 KONFIGURATION 3 CONFIGURATION 3 CONFIGURACI N 3 Sonda puffer Heat Storage probe Puffer Fuehler Sonde brancher dans le ballon tampon Sonda deposito inercial PANNELLO SOLARE Componenti compresi nella stufa Components included in the stove Komponenten enthalten in den Ofen Composants prevus dans le po le Piezas incluidas en el kit estufa Sonda puffer Heat Storage probe Puffer Fuehler S
9. a worn component before it malfunctions helps prevent accidents due to sudden breakages which may cause serious harm to people and things Perform the periodical maintenance checks as described in the chapter on Maintenance 1 13 IDENTIFICATION LABEL The serial number plate on the boiler shows all the typical product data including the manufacturer s details the serial number and C markings 1 14 DELIVERY OF THE BOILER The boiler is delivered packaged and secured to a wooden pallet for handling by forklift and or other equipment The following material is provided inside the boiler e installation user and maintenance manual e flue gas attachment 33 134 P WI WIL ECAA N PED Bb ier PALAZZET TI N N gt SAFETY WARNINGS INSTALLATION WARNINGS Comply with the requirements specified in thismanual The boiler assembly and dismantling instructions are reserved exclusively for specialist technicians Users should always contact our service centre to request work to be performed by qualified technicians Before having work performed by other technical personnel verify their effective technical competence Responsibility for work carried out in the place where the boiler is installed lies with the user the user is also responsible for making sure the installation checks are completed The user must abide by all local national and European safety requirements The appliance m
10. and move it up and down to remove the soot deposits from the tubes Fig 12 6 Remove the lever and put it back in its original place Use a special ash vacuum cleaner to vacuum up the residues on the flue gas manifold 12 2 5 Cleaning the glass This is done using a damp cloth or moistened paper passed through the ash Rub until the glass is clean Fig 12 7 Detergents suitable for cleaning kitchen ovens can also be used Never clean the glass while the boiler is operating and never use abrasive sponges Do not wet the door gasket as this may be damaged 12 2 6 Cleaning the flue This should be performed at least twice a year at the start of and half way through winter and in any case whenever necessary Fig 12 8 If there are horizontal sections check for and remove any accumulated ash and soot before these block the flow of flue gas If not cleaned correctly the boiler may not operate properly with problems including poor combustion blackening of the glass blockage of the burn pot by ash and pellets accumulated ash and excessive fouling of the heat exchanger with a consequent decline in efficiency 12 2 7 Cleaning the outside of the boiler The outside of the boiler must only be cleaned using a dry non abrasive cloth Do not use detergents and never clean when the boiler is hot Fig 12 8 54 134 cod 004772540 05 2013 Palazze
11. confirm d The value will flash change it using the and buttons 8 40 C e Press the button to confirm the set value 10 9 INTEGRATED PRODUCTION OF SANITARY HOT WATER Only in models equipped with an hydraulic unit for the production of sanitary hot water it is possible to produce into the boiler also sanitary hot water in addition to hot water for heating systems This production can take place only if the boiler is operating If the boiler is switched off sanitary hot water cannot be produced cod 004772540 05 2013 Palazzetti PN Italy 51 134 PALAZZETTI USE AND amp MAINTENANCE 11 ALARM MANAGEMENT If a malfunction occurs the following procedure is activated 1 audible alarm beep 2 one of the following system LEDs come on bd WA 3 ifthe problem concerns an error the boiler will switch off Pressing and holding the cancel button shows the error code on the display ERROR WARNING CODE DESCRIPTION POSSIBLE CAUSES LED EGOI Faulty control panel Control panel fault VA ope Remote control signal communication error Control panel fault VA nnd SS poe board and control panel N interrupted or detached C t EUU S If this appears when changing configuration ignore the Pd error No pellets Pellet quality EID Failed ignition error Faulty ignition system A Outlet water temperature too high Burn pot dirtv Problems with the heat
12. must remain closed during operation Operation on traditional wood is not possible The boiler must not be used as a rubbish incinerator STORING THE PELLETS The pellets must be kept in a place that s dry and not too cold Its suggested to keep some sacks of pellets in the same room where the boiler is installed or an adjacent room as long as the temperature and humidity are acceptable Damp and or cold pellets 5 C reduce the fuel heat value and mean the burn pot unburned material and boiler will need to be cleaned more frequently Pay special care when storing and handling the sacks of pellets Make sure these are not crushed to prevent the pellets from becoming sawdust Sawdust introduced into the hopper may block the pellet feed system Use of poor quality pellets may affect normal pellet boiler operation and render the warranty void The features of the pellets must comply with the requirements of EN 14961 2 cod 004772540 05 2013 Palazzetti PN Italy PALAZZET TI Fig 3 1 4 HANDLING AND TRANSPORT The boiler is delivered complete with all parts included Beware of the tendency of the boiler to tip over The boiler s centre of gravity is towards the front of the appliance Always keep this in mind when moving the boiler on the transport pallet When lifting avoid jolts or sudden movements Make sure that the forklift capacity exceeds the weight of the boiler being lifted The operat
13. surface are prohibited by law and affect proper boiler operation The flue gas can be discharged through a traditional chimney Fig 5 8 as long as the following rules are observed check the conditions of the chimney old chimneys should be renovated by introducing steel piping with suitable insulation rock wool vermiculite the flue gas can be discharged directly into the chimney only if the latter has a maximum cross section of 15 x 15 cm or diameter of 15 cm and features an inspection opening For larger chimneys suitably insulated steel pipes need to be inserted on the inside diameter according to the length Fig 5 9 Makes sure connections to brick chimneys are suitably sealed Avoid contact with combustible materials e g wooden beams and in any case insulate these using fireproof material metres If the flues run through wooden roofs or walls C Seal special certified pass through kits need to be used D Inspection available on the market Il m Z 7 I A Chimney pot with wind protection Fig 5 8 B Maximum cross section of 15 x 15 cm or diameter of 15 cm and maximum height of 4 5 1 Vermiculite and or rock wool 2 Steel pipes 3 Closure panel Fig 5 9 cod 004772540 05 2013 Palazzetti PN Italy 39 134 PALAZZET TI INSTALLATION 6 6 1 6 2 6 2 1 6 2 1 1 6 2 2 6 2 3 6 2 4 6 2 5 INSTALLATION ar A T
14. surfaces For this reason maximum care must be paid during operation specifically do not touch or get too close to the door to avoid getting burned donot touch the flue donot perform any type of cleaning 34 134 INTRODUCTION s do not remove the ash do not open the door e do not open the ash bin make sure children keep away from the boiler Comply with the requirements specified in this manual e Follow the instructions and warnings highlighted on the metal labels affixed to the boiler These labels are safety devices therefore they must always be perfectly legible If damaged or illegible they must be replaced contacting the manufacturer for an original spare label Only use fuel compliant with the specifications shown in the corresponding chapter of this manual Strictly follow the routine and special maintenance plan e Donotusethe boiler without first having performed the daily inspection as specified in the chapter on Maintenance in this manual e Donotuse the boiler in the event of malfunctions suspected breakage or unusual noises e Do not pour or spray water onto the boiler when operating orto extinguish the flame in the burn pot e Do not switch the boiler off by unplugging the power cord e Do not rest your weight on the open door as this may affect stability e Do not use the boiler in any way as a support or anchor e Do not clean the boiler until the structure an
15. the and buttons 4 Small pellets 2 Medium sized pellets 3 Large pellets e Press to confirm the settings cod 004772540 05 2013 Palazzetti PN Italy 47 134 PALAZZET TI USE AND amp MAINTENANCE 9 BOILER OPERATION 9 1 STARTING THE BOILER To start the boiler hold the 6 button for several seconds The flame icon will start flashing during the ignition stage until remaining on steady when the boiler has started Automatic boiler ignition the boiler comes with an automatic device that starts the pellet boiler without using other traditional fire lighters AN Avoid lighting the flame manually if the boiler s automatic ignition system is not working correctly When the boiler is started the first time unpleasant odours or smoke may be generated caused by evaporation or drying of certain materials used This phenomenon will gradually disappear The room should be well ventilated when starting the boiler the first few times 9 2 MODIFYING THE PARAMETERS The boiler operating parameters can be modified as described in paragraph 7 3 C amp 7 The values set will be retained until next modified even when the boiler is switched off or unplugged from the power supply 9 3 SWITCHING OFF To switch the boiler off hold the 6 button for a few seconds the flame icon will switch off C amp 7 To start the boiler again it s recommended to wait for the boiler to cool down completely AN The boiler
16. the button displays any active alarm or error codes 44 134 cod 004772540 05 2013 Palazzetti PN Italy USE AND amp MAINTENANCE PALAZZETTI 7 3 OPERATING PARAMETERS Boiler operation is determined by the Power level and Temperature parameters set by the user 7 3 1 setting the power level The power level defines the amount of heat produced by the boiler and consequently directly affects fuel consumption a Use the q buttons to go to the power menu and press l b The power level value will flash set the value using the buttons 1 minimum 5 maximum c Press to confirm the settings m Z E 7 I 7 3 2 Setting the temperature Different temperature values can be set depending on the boilers configuration a Use the lt D buttons to go to the temperature menu E and press b The current value will flash change it using the buttons c Press to confirm the settings Water temperature configurations 1 only setting this value changes the desired hot water outlet temperature Room temperature configuration 2 only setting this value defines the desired room temperature read directly by a probe fitted on the boiler Storage temperature configurations 3 and 4 only identifies the minimum desired temperature inside the storage tank cod 004772540 05 2013 Palazzetti PN Italy 45 134 PALAZZET TI 8 8 1 8 2 8 3 8 3 1 PRELIMINARY OPER
17. ATIONS LOADING THE PELLETS The first operation to be performed before starting the appliance is to fill the hopper with fuel pellets The pellets are loaded into in the hopper using a SCOOP Do not empty the sack directly into the hopper so as to avoid loading sawdust or other foreign bodies that may affect proper boiler operation and avoid spilling pellets outside of the hopper Make sure the hopper lid is well closed again after having loaded the pellets At this point to take advantage Autonomy function use the arrow buttons to move to the combustible icon lt s and confirm by pressing e Select Full bv pressing and press 6 button to confirm In order to disable this function select Off instead of Full POWER SUPPLY Plug the boiler into the mains power supply move the power switch at the rear of the boiler to position I Fig 8 2 If the connections are correct the boiler will emit a series of intermittent beeps the display will come on If not using the appliance for an extended period the switch at the rear of the boiler should be moved to position O INITIAL SETTINGS The language current date and time need to be set before using the boiler Time and Date setting To set the date USE AND amp MAINTENANCE Fig 1 Fig 2 a Use the lt D buttons to go to t
18. ED flashing boiler in the ignition stage or in standby LED off boiler off 43 134 PALAZZETTI USE AND amp MAINTENANCE 7 1 2 Description of the menus ICON FUNCTION DESCRIPTION VALUES Power Stove output setting 1 5 se Fan This parameter is not enabled on water heating models Displays the room temperature reading and is used to set the desired i W Temperature temperature 6 C 51 C Displays the operating autonomy and resets the value when filling the _ ls Fuel pellet hopper L FULL 1 or deactivates the warning L UFF j 9 Timer Enables or disables the timer When enabled the icon d will be ON OFF displaved steadv not flashing ICON FUNCTION SUBMENU DESCRIPTION VALUES 13 Weekly timer 7 the programs max 3 to the different days of the d1 d7 Ce Programs Program setting menu P1 P6 33 Time date Time and date setting Displays the number of hours remaining until recommended 4 Hours remaining maintenance When Hi is displayed the remaining time exceeds 999 hours 5 ou Displays the current software version information 8 Water It allows to set the desired temperature for the water supply 60 80 C temperature only in configuration 2 UU Enables or disables Eco Mode in which the stove L 1 Eco function automatically switches off and on based on room temperature OFF Eco only in configuration
19. G AND nanna 55 St ELECTRICIAN TINTRODUC TION 2 aaacasa 32 2 SAFETY WARNINGS coissi u A r aE E ER E O aE p a aS 34 4 HANDLING AND TRANSPORT iii 35 13 DECOMMISSIONING AND DISPOSAL nr 55 SHUNTER TRANSPORTER 30 134 cod 004772540 05 2013 Palazzetti PN Italy PALAZZETTI INDEX 1 INTRODUCTION 32 10 FUNCTIONS AVAILABLE 49 1 1 SYMBOLS 32 10 1 TIMER FUNCTION 49 1 2 INTENDED USE 32 10 2 ECO MODE SAVING FUNCTION 50 1 3 PURPOSE AND CONTENTS OF THIS MANUAL 32 10 3 AUTONOMY FUNCTION 50 1 4 HOW TO KEEP THIS MANUAL 32 10 4 REFILL FUNCTION 50 1 5 UPDATES TO THE MANUAL 32 10 5 RESTARTING AFTER A POWER FAILURE 50 m 1 6 GENERAL INFORMATION 32 10 6 LOCK KEYPAD FUNCTION 50 wa 1 7 MAIN REFERENCE STANDARDS 33 10 7 FROST PROTECTION FUNCTION 51 G 1 8 PRODUCT WARRANTY 33 10 8 RESTART DELTA FUNCTION 51 19 MANUFACTURER S LIABILITY 33 10 9 INTEGRATED PRODUCTION OF SANITARY HOT o 1 10 INTENDED USERS 33 WATER 51 L 1 11 TECHNICAL SERVICE 33 1 12 SPARE PARTS 33 1 13 IDENTIFICATION LABEL 33 11 ALARM MANAGEMENT 52 1 14 DELIVERY OF THE BOILER 33 12 MAINTENANCE 53 2 SAFETY WARNINGS 34 12 1 SAFETY PRECAUTIONS 53 21 INSTALLATION WARNINGS 34 12 2 ROUTINE USER MAINTENANCE 53 22 MAINTENANCE WARNINGS 34 12 3 SPECIAL MAINTENANCE 55 2 3 WARNING FOR THE USER 34 13 DECOMMISSIONING AND DISPOSAL 55 3 FUEL SPECIFICATIONS 35 3 1 FUEL SPECIFICATIONS 35 14 HYDRAULIC DIAGRAM 134 3 2 STORING THE PELLET
20. OTRE NOUVEAU CHAUDI RE GRANUL S NOUS VOUS INVITONS SUIVRE ATTENTIVEMENT LES INSTRUCTIONS REPORT ES DANS CETTE NOTICE ESTIMADO CLIENTE ES DESEAMOS AGRADECERLE POR LA PREFERENCIA QUE NOS HA OTORGADO ADQUIRIENDO NUESTRO PRODUCTO Y LO FELICITAMOS POR SU ELECCI N PARA EL MEJOR USO DE SU NUEVA CALDERA DE PELLETS LO INVITAMOS A LEER CON ATENCI N CUANTO SE DESCRIBE EN EL PRESENTE MANUAL cod 004772540 05 2013 Palazzetti PN Italy 3 134 PALAZZET TI SUMMARY FOR SKILLS TINTRODUC TION sige 32 w 2 SAFETY WARNINGS TE 34 4 3 FUEL SPECIFICATIONS 5i i 35 8 PRELIMINARY OPERATIONS uuu ninna aai aditi on 46 S BOILER OP ERAN 2 48 TO FUNCTIONS AVAILABLE eor o e Rn EO SE En nU aaa 49 11 SN ELUCET 52 12 MAINTENANCE m 53 13 DECOMMISSIONING AND DISPOSAL ran 55 LINTRODUGTION m 32 ZSAPETY WARNING U ies ta eee ene ees ea ee eee ete esr oa 34 S FUEL SPECIFICATIONS uu u ene cere ec aac ara E MISSE 35 4 HANDLING AND TRANSPORTI 35 5 INSTALLATION SITE PREPARATION iii 36 SINS TALCA TON car uuu Sum a au mas 40 TBOIEER DESCRIPTION u uu ail 43 PRELIMINARY OPERATIONS uu u uuu i gideb BA 46 a i MAINTENANGE ii uuu EE M 53 13 DECOMMISSIONIN
21. PALAZZETTI IL CALORE CHE PIACE ALLA NATURA MANUALE DI INSTALLAZIONE USO E MANUTENZIONE INSTALLATION USER AND MAINTENANCE MANUAL INSTALLATIONS BEDIENUNGS UND WARTUNGSANLEITUNGEN NOTICE D INSTALLATION MANUAL DE INSTALACION USO Y MANTENIMIENTO CALDAIA A PELLET PELLET BOILER PELLETKESSEL CHAUDIERE PELLET CALDERA DE PELLET PALAZZETTI GENTILE CLIENTE IT DESIDERIAMO INNANZITUTTO RINGRAZIARLA PER LA PREFERENZA CHE HA VOLUTO ACCORDARCI ACQUISTANDO IL NOSTRO PRODOTTO E CI CONGRATULIAMO CON LEI PER LA SCELTA PER CONSENTIRLE DI UTILIZZARE AL MEGLIO LA SUA NUOVA CALDAIA A PELLET LA INVITIAMO A SEGUIRE ATTENTAMENTE QUANTO DESCRITTO NEL PRESENTE MANUALE DEAR CUSTOMER 3B WE D LIKE TO THANK YOU FOR HAVING PURCHASED ONE OF OUR PRODUCTS AND CONGRATULATE YOU ON YOUR CHOICE TO MAKE SURE YOU GET THE MOST OUT OF YOUR NEW PELLET BOILER PLEASE CAREFULLY FOLLOW THE INSTRUCTIONS PROVIDED IN THIS MANUAL SEHR GEEHRTER KUNDE DE ZUALLERERST M CHTEN WIR IHNEN F R DEN UNS GEW HRTEN VORZUG DANKEN UND ZUR WAHL GRATULIEREN DAMIT Sie IHREN NEUEN PELLETKESSEL SO GUT WIE M GLICH BENUTZEN K NNEN BITTEN WIR SIE DIE IN DIESER BEDIENUNGS UND WARTUNGSANLEITUNG ENTHALTENEN ANGABEN GENAU ZU BEFOLGEN CHER CLIENT F NOUS SOUHAITONS AVANT TOUT VOUS REMERCIER DE LA PR F RENCE QUE VOUS NOUS AVEZ ACCORD E EN ACHETANT NOTRE PRODUIT ET VOUS F LICITIONS POUR VOTRE CHOIX AFIN DE VOUS PERMETTRE DE PROFITER AU MIEUX DE V
22. S 35 4 HANDLING AND TRANSPORT 35 5 INSTALLATION SITE PREPARATION 36 5 1 GENERAL INFORMATION 36 5 2 SAFETY PRECAUTIONS 36 5 9 BOILER INSTALLATION SITE 36 5 4 COMBUSTION AIR 37 5 5 FLUE GAS EXHAUST 38 6 INSTALLATION 40 6 1 LEVELLING THE BOILER 40 6 2 SYSTEM CONNECTIONS 40 6 3 INITIAL CONFIGURATION 41 7 BOILER DESCRIPTION 43 7 1 CONTROL PANEL 43 7 2 USING THE CONTROL PANEL 44 7 3 OPERATING PARAMETERS 45 8 PRELIMINARY OPERATIONS 46 8 1 LOADING THE PELLETS 46 8 2 POWER SUPPLY 46 8 3 INITIAL SETTINGS 46 9 BOILER OPERATION 48 9 1 STARTING THE BOILER 48 9 2 MODIFYING THE PARAMETERS 48 9 3 SWITCHING OFF 48 9 4 OPERATION WITH ROOM THERMOSTAT 48 9 5 OPERATION WITH ROOM PROBE ON THE BOILER 16 9 6 OPERATION IN COMBINATION WITHA STORAGE TANK 48 cod 004772540 05 2013 Palazzetti PN Italy 31 134 PALAZZET TI 1 1 1 1 2 INTRODUCTION PALAZZETTI heating appliances are built and tested in accordance with the safety requirements specified by the relevant European directives This manual is intended for owners installers users and maintenance personnel of the PALAZZETTI pellet boilers and is an integral part of the product If there are any doubts regarding the contents of this manual or for any other explanations please contact the manufacturer or an authorised service centre quoting the paragraph number in question No printing translation and reproduction of this manual in part or whole is allowed wi
23. Use the arrow buttons 3 D to go to the setup menu T and then press b Use the button to select the password 7 and then press to confirm Select submenu L 1 and confirm by pressing d Set one of the following values using the buttons ECO Eco Mode function enabled OFF Eco Mode function disabled e Press to confirm the settings 10 3 AUTONOMY FUNCTION This function is used to display the number of hours of operating autonomy remaining before having to refill with pellets Use the arrow buttons to move to the gt symbol and display the estimated operating hours before having to refill with pellets The autonomy is calculated according to the operating parameters set at that moment on the stove The estimated values are quite reliable as long FULL is selected and confirmed whenever refilling the stove completely Lo indicates the reserve fuel level 10 4 REFILL FUNCTION This function is used to tell the stove that the hopper is being filled with pellets In this way the stove can estimate based on the operating parameters how many hours of autonomy remain before having to fill the hopper with pellets again After having completely filled the pellet hopper a Use the arrow buttons lt D to move to the fuel icon li and press ente b Use the buttons to select FULL and press enter To disable this function select UFF instead of FULL
24. alth of workers at work E Directive 89 106 EEC Approximation of the laws regulations and administrative provisions of the Member States relating to construction products F Directive 85 374 EEC Approximation of the laws regulations and administrative provisions of the Member States concerning liability for defective products Directive 1999 5 EC Radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity H Standard EN 303 5 2012 Concerning heating boilers for solid fuels Heating boilers for solid fuels hand and automatically stoked nominal heat output up to 500 kW PRODUCT WARRANTY In order to make use of the product warranty pursuant to Directive 1999 44 EC users must fully comply with the instructions specified in this manual and specifically e always use the boiler within its operating limits e always carry out regular and thorough maintenance e allow the boiler to be used by people of proven ability attitude and suitably trained for the purpose e use original spare parts made specifically for the model of boiler in question In addition the following must be provided e tax receipt showing the purchase date e certificate of conformity of installation issued by the installer Failure to follow the instructions provided in this manual will render the warranty void MANUFACTURER S LIABILITY By providing this manual PALAZZETTI decli
25. based on the type of configuration 4 9 e The current time is shown The operating autonomy in hours before having to refill the hopper is shown If the function 4 filling has been activated e Press to confirm the settings 8 3 3 Setting the display brightnes Display brightness when in standby mode can be set a Use the arrow buttons 9 to go to the setup menu T and then press b Use the button to select the password 7 and then press lt to confirm c Use the button to scroll to and select submenu L I and press to confirm d Set the desired brightness OFF 8 using the buttons and press to confirm 8 3 4 Setting the volume The volume of the buzzer can be set based on requirements a Use the arrow buttons lt D to go to the setup menu Yl and then press 4 b Use the button to select the password 7 and then press to confirm c Use the button to scroll to and select submenu 3 and press to confirm d Set the desired volume OFF 1 to 5 using the buttons and press to confirm 8 3 5 Setting the type of pellets The type of pellets used can be set a Use the arrow buttons J D to go to the setup menu and then press b Use the button to select the password 7 and then press to confirm c Use the button to scroll to and select submenu 14 and press to confirm d Set one of the following values using
26. by pressing d Use the 3 buttons to choose the day d1 d7 to assign the programs to e Select this using the button f The value of the first program to assign will flash P P6 or OFF to disable g Set the value using the buttons and press Dy h The value of the second program to assign will flash P i or DFF to disable i Set the value using the buttons and press b j The value of the third program to assign will flash i or OFF to disable k Set the value using the buttons and press to confirm the settings 10 1 3 Enabling disabling the timer a Use the arrow buttons lt D to go to the Timer menu Q b Select this using the button C Use the buttons to scroll and select 0M to enable the timer or OFF to disable it d Press to confirm the selection When the timer is enabled the 14 icon will be on steady indicating that the timer is active cod 004772540 05 2013 Palazzetti PN Italy 49 134 PALAZZET TI USE AND amp MAINTENANCE 10 2 ECO MODE SAVING FUNCTION Enabling this function means that the stove switches off when reaching the desired room temperature If this function is not enabled the stove modulates operation so as to maintain the desired temperature while consuming the least amount of fuel possible The Eco Mode function is only available in configuration 2 To enable disable the function a
27. d ash have completely cooled down e Touch doors only when the boiler has cooled down e Perform all operations without haste in such a way as to ensure maximum safety e Inthe event of fire in the chimney switch the boiler off using the procedure described later e Inthe event of boiler malfunctions due to flues with incorrect draught clean the flue according to the procedure described in the Maintenance chapter e The flue must be cleaned as described in the Maintenance chapter s Do not touch the painted parts during operation to avoid damaging the paintwork cod 004772540 05 2013 Palazzetti PN Italy 8 gt D INTRODUCTION FUEL SPECIFICATIONS FUEL SPECIFICATIONS Pellets Fig 3 1 are made from various types of mechanically compacted wood in compliance with environmental protection standards Pellets are the only fuel that can be used on this type of boiler The efficiency and heat output of the boiler may vary in relation to the type and quality of pellets used The pellet boiler requires pellets with the following characteristics e diameter 6 mm max length 30 mm max moisture content lt 12 9 e ash content lt 0 596 calorific value gt 17 MJ kg dry base The boiler has a pellet hopper with the capacity specified in the technical data table The pellet hopper is located at the top of the boiler It must always be able to be opened to load the pellets and
28. e last few pages of the booklet cod 004772540 05 2013 Palazzetti PN Italy 41 134 PALAZZETTI USE AND amp MAINTENANCE USE AND amp MAINTENANCE l 42 134 cod 004772540 05 2013 Palazzetti PN Italy USE AND amp MAINTENANCE PALAZZETTI 7 BOILER DESCRIPTION Before reading this booklet check the description of the boiler provided in the Product Booklet enclosed 7 1 CONTROL PANEL The control panel consists of A a top part with status LEDs and backlit icons that identify each function LED display ON button D Cancel and display error button functions F twobuttons and to access the submenus and set the operating parameters G an enter button 5 confirm the parameter or the settings 5 Allthe buttons are capacitive therefore the functions are activated without needing to press hard on the buttons rather by just touching the surface 7 1 1 STATUS LEDS WARNING two arrow buttons to scroll between the various DESCRIPTION Pellets running out Indicates that the pellet hopper needs to be refilled Maintenance Indicates the need to perform maintenance Service ndicates an error Remote control receiver OPTIONAL Timer active Indicates whether the timer function is active Status LED near the 6 button cod 004772540 05 2013 Palazzetti PN Italy LED on steady boiler on and operating L
29. he best configuration needs to be selected for boiler operation Before proceeding power up the boiler using the safety switch on the rear a Use the arrow buttons lt D to go to the setup menu Yl and then press b Use the button to select the password 7 and then press to confirm c Use the buttons to scroll to and select submenu 30 0 will flash on the display d Press lt and enter the value 54 using the buttons e Press to confirm f The current configuration will be displayed g To change the configuration press and enter the value of the new configuration using the buttons h Press to confirm After having changed the configuration a communication error message may be displayed for a few seconds Ignore this and switch the boiler off using the safety switch on the rear wait a few seconds and switch it back on FOUR DIFFERENT CONFIGURATIONS ARE AVAILABLE CONFIGURATION 1 Set this configuration when the boiler is controlled by an external thermostat or timer thermostat This configuration can also be used to switch the boiler on or off manually or by timer without using an external thermostat but rather leaving the two terminals jumpered as per the factory setting In this configuration the boiler switches off when reaching the external thermostat setting or alternatively modulates output to minimise fuel consumption when reaching the set water temperature
30. he boiler must be installed by qualified personnel in compliance with EN 10683 that must also provide verbal instructions to the user before using the appliance for the first time LEVELLING THE BOILER The boiler must be levelled by adjusting the feet then checked using a spirit level SYSTEM CONNECTIONS Electrical connection The boiler is connected to the electrical system simply using the plug supplied The electrical connection plug must be easily accessible when the boiler is installed If the power cord is damaged it must be replaced by the technical service or a qualified technician to prevent any kind of risk Earth The system must be earthed and fitted with a residual current circuit breaker in accordance with legislation in force Fig 6 2 The flue must have its own earth connection Connection to an external timer thermostat The boiler can be connected to an external timer thermostat that switches the boiler on or off according to the set temperature When the set temperature is reached the thermostat opens the circuit and consequently switches off the boiler The external thermostat is connected to the two terminals on the rear of the boiler which are jumpered in the factory Disconnect the jumper and connect the two thermostat contacts The boiler must be set to configuration 1 following the instructions shown in the paragraph on Initial configuration After first installing the timer thermostat the boi
31. he flue gas exhaust attachment MUST NOT BE connected to e a chimney used by other heat generators boilers boilers fireplaces etc air exhaust systems range hoods vents etc even if these are ducted Shut off or draught valves must not be used Combustion byproducts must be discharged through the roof If the flue is longer than 5 metres and there is insufficient draught many changes in direction unsuitable discharge terminal etc flue gas exhaust may be less than optimum In these cases the operating parameters will need to be modified flue gas exhaust and pellet load to adapt the boiler to the actual characteristics of the flue Contact technical service for this procedure Make one or more holes that must be sealed on the exhaust pipe fitting to allow the control of the emissions after the installation 38 134 3 ba WES Sh L B B Q10cm L E e N x Y Fig 5 5 Fig 5 6 cod 004772540 05 2013 Palazzetti PN Italy INSTALLATION PALAZZET TI 5 5 1 Discharge through roof using a traditional A chimney The chimney used to discharge the flue gas must be made in accordance with standards UNI 10683 EN 1856 1 2 EN 1857 EN 1443 EN 13384 1 3 EN 12391 1 both as regards the dimensions and the construction materials used DAMAGED chimneys made from unsuitable material asbestos cement galvanised steel etc with a rough and porous inside
32. he setup menu Yl and press b Use the button to select the password 7 and then press to confirm c Use the button to scroll to and select submenu L 33 and press to confirm d The hour value will flash set the value using the buttons and press D e The minutes value will flash set the value using the buttons and press gt f The day value will flash set the value using the buttons and press D g The month value will flash set the value using the buttons and press D h The year value will flash set the value using the buttons and press D i The current weekday value will flash Monday 1 Sunday 7 set the value using the buttons j Press lt to confirm the settings 46 134 cod 004772540 05 2013 Palazzetti PN Italy USE AND amp MAINTENANCE PALAZZETTI 8 3 2 Setting the display mode The data shown on the display when this is in standby mode can be set a Use the arrow buttons 9 to go to the setup menu X and then press b Use the button to select the password 7 and then press to confirm c Use the button to scroll to and select submenu L ie and press lt to confirm d Set one of the following values using the and buttons OFF The display remains on the last operation set by the user 1 All operating parameters are displayed cyclically 2 The room or water probe temperature is shown
33. in such a way that it can t be accidentally obstructed If it s not possible to make a fresh air opening in the wall behind the boiler not a perimeter wall an opening must be made on the wall in the room where the boiler is installed that faces the outside If no fresh air opening can be made in the room it can be made in an adjacent room as long as the two rooms are connected by a ventilation grill Fig 5 4 C Shutter box G Grill S Shutters Standard UNI 10683 prohibits combustion air being drawn in from garages combustible material stores or places where there is a fire risk If there are other heating appliances in the same room the fresh air vents must guarantee the required volume of air for correct operation of all the appliances If one or more exhaust fans range hoods are installed and operating in the room where the boiler is located combustion problems may occur due to a lack of combustion air If in the room there are other generators the total amount of burned power must not exceed 35 kW and ventilation should be properly calculated based on the total of the power and the technical specifications of the generators m us 7 I 0 AH AA AA AH LL L H H HHHH Fig 5 4 cod 004772540 05 2013 Palazzetti PN Italy 37 134 PALAZZETTI MA 0 5 5
34. ing svstem Problems with the pump E105 Temperature probe malfunction Faulty return water temperature probe VA E105 Temperature probe malfunction Faulty buffer tank temperature probe VA Safety error Door open VA Flue gas exhaust system dirty Seal gaskets worn Insufficient combustion air P th safet E103 Problems with the heating system Pd Problems with the pump Problems with overheating in the pellet hopper Faulty outlet water temperature probe T t b Ifunct EMO valise SA A Faultv air temperature probe Pd E Flue gas temperature probe malfunction Faulty flue gas temperature probe Pd A A HDD Low pellet level icon flashing Pellets running out A Scheduled maintenance warning icons The boiler periodically requires maintenance to be 71 HUUC flashing performed bv a Qualified technician S CA 2 9001 Pressure sensor malfunction icon pressure sensor or board fault F flashing f Combustion chamber burn pot or flue gas exhaust system dirty Pi m Clean boiler Pressure measuring tubes detached or blocked Combustion air intake blocked dad inniti No pellets Faulty ignition heater Worn gaskets Incorrect Failed ignition error Pum pot Position g g bd Only for the models equipped with safety microswitches on the door or on the hopper lid ter having checked the type of message the alarm can be reset by pressing the on off button for a few moments In case of error E109 or E108
35. ler needs to be switched on manually Fig 6 2 while the timer thermostat is in call status This operation is also required in the event of power failures or if the boiler is switched off manually To avoid overlapping the working time bands it s recommend to disable set to OFF the boiler s timer see par 10 1 Operation with room probe In certain circumstances the boiler may need to modulate operation based on the temperature read by the room probe fitted on the boiler The boiler must be set to configuration 2 following the instructions shown in paragraph 6 3 Connection to a storage tank with coil The boiler can be used to maintain the temperature inside a storage tank fitted with coll In this case simply disconnect the external temperature probe from the boiler and fit it in the probe socket on the storage tank The boiler must be set to configuration 3 following the instructions shown in paragraph 6 3 Connection to a storage tank without coil The boiler can be used to maintain the temperature inside a storage tank without coll In this case simply disconnect the external temperature probe from the boiler and fit it in the probe socket on the storage tank The boiler must be set to configuration 4 following the instructions shown in paragraph 6 3 40 134 cod 004772540 05 2013 Palazzetti PN Italy USE AND amp MAINTENANCE PALAZZETTI 6 3 INITIAL CONFIGURATION Depending on the type of installation t
36. lly A do not work in adverse conditions B always be in a fit mental physical state for working and make sure that personal protective equipment is in perfectly working order C always wear safety gloves always wear safety shoes E always use electrically insulated tools make sure that the area being used for assembly and dismantling is clear of any obstacles 36 134 INSTALLATION 5 3 BOILER INSTALLATION SITE Fig 5 1 and the corresponding table show the minimum clearances from objects expressed in centimetres that must be observed when positioning the boiler to ensure safety and access for maintenance A Adjacent wall B Rear wall C Side wall D Protective flooring LL L Es mi L LI Fig 5 1 Protect all structures that mav catch fire if exposed to excessive heat for both the boiler and the flue gas attachment Floors made from flammable materials such as wood parquet linoleum laminates or carpets must be protected by a suitably sized fireproof base underneath boiler Such base may be made from steel slate glass or stone and must cover the floor in the part underneath the boiler and the flue attachment and must extend at least 50 cm at the front The manufacturer declines all liability for any alterations to the characteristics of the material making up the floor underneath the protective base Any eleme
37. matically switching the stove on and off Up to six customised programs can be set For each program the following can be set on time off time and desired temperature Up to three programs can be assigned for each day of the week The days of the week are identified by numbers Monday d1 Tuesday d2 Sunday 10 1 1 Setting the programs a Use the arrow buttons Q D to go to the setup menu Yl and then press b Use the button to select the password 7 and then press to confirm Select submenu 2 and confirm by pressing d Use the buttons to scroll the programs P1 P6 e The on hours value will flash set the value using the buttons and press D f The minutes value will flash set the value using the buttons and press gt g The off hours value will flash set the value using the buttons and press Dy h The minutes value will flash set the value using the buttons and press DI i The desired temperature value will flash set the value using the buttons and press gt j Press to confirm the settings 10 1 2 Assigning the programs to specific days This function can be used to assign up to three different programs to a certain day a Use the arrow buttons lt D to go to the setup menu Yl and then press 4 b Use the button to select the password 7 and then press to confirm c Select submenu J and confirm
38. mpts to maintain the desired temperature while minimising fuel consumption If the user has enabled the Eco mode function under submenu L 1 of the setup menu the boiler rather than modulating its output switches off when reaching the set temperature and switches on again when the room temperature falls below the delta set in submenu 1 of the setup menu The desired room temperature can be set in temperature menu CG Submenu L b Jof the setup menu can be used to set the desired water outlet temperature the best temperature for the heating system in question should be suggested by the heating system installer 9 6 OPERATION IN COMBINATION WITH A STORAGE TANK For operation in combination with a storage tank the installer will have set configuration 3 or 4 depending on whether the storage tank is with or without a coil inside The boiler is controlled based on the temperature read by the probe in the storage tank When reaching the storage tank temperature set in the temperature menu e the boiler switches off and switches on again if the temperature falls below the delta set in submenu L BJ of the setup menu 1 The frost protection function can also be set in this configuration 48 134 cod 004772540 05 2013 Palazzetti PN Italy USE AND amp MAINTENANCE PALAZZETTI 10 FUNCTIONS AVAILABLE 10 1 TIMER FUNCTION Its possible to set enable and assign to the various days of the week customised programs for auto
39. nes all liability both civil and criminal direct or indirect deriving from e installation not in compliance with the standards in force in the country concerned and with safety directives e partial or total failure to follow the instructions provided in this manual e installation by unqualified and untrained personnel use not in compliance with safety directives modifications and repairs on the boiler that are not authorised by the manufacturer G So cod 004772540 05 2013 Palazzetti PN Italy PALAZZETTI use of spare parts that are not original or not specific for the model of boiler lack of maintenance exceptional events 1 10 INTENDED USERS The user of the boiler must be a responsible adult with sufficient technical knowledge to carry out routine maintenance on the parts of the boiler Make sure children do not play close to the boiler while it s operating TECHNICAL SERVICE PALAZZETTI has an extensive network of service centres staffed by specialists trained directly by the company Please contact our head office or sales network for details of your nearest authorised service centre The company forum http forum palazzetti it offers access to a vast amount of information and allows users to exchange ideas opinions and suggestions 1 12 SPARE PARTS Only use original spare parts Do not wait for components to become worn out before replacing them Replace
40. nts made from wood e g beams or other combustible material located near the boiler should be protected with fireproof material Flammable walls or elements must be kept at least 80 cm away from the boiler cod 004772540 05 2013 Palazzetti PN Italy INSTALLATION PALAZZETTI Leave enough clearance for maintenance work Make sure the minimum distance from flammable materials x is observed as shown on the pipes PI used to make up the flue or chimney Fig 5 2 Pi Combustible wall Pp Floor protection 5 4 COMBUSTION AIR During operation the boiler takes in a certain amount of air from the room where it s installed this air must be replaced through an opening to the outside from the room Fig 5 3 PA Fresh air vent If the wall behind of the boiler is an outside wall Pi make an opening for drawing in combustion air NA around 20 30 cm above the floor observing the xw 150 cm dimensions shown on the product data sheet at e the end of this booklet wir ix In general the minimum opening section required Z for the air intake must be 6 cm per kW of power minimum section possible 100 cm2 if near the ria Pp L floor otherwise it must be increased by 50 A permanent non closable vent cover must be placed on the outside of the opening in especially windy areas or places exposed to bad weather install rain and wind protection elements Fig 5 2 Make sure that the air vent is located
41. onde brancher dans le ballon tampon Sonda deposito inercial Components included in the stove Komponenten enthalten in den Ofen Composants prevus dans le po le Piezas incluidas en el kit estufa cod 004772540 05 2013 Palazzetti PN Italy 135 136 PALAZZET TI IL CALORE CHE PIACE ALLA NATURA Palazzetti Lelio s p a Via Roveredo 103 cap 33080 Porcia PN ITALY Internet www palazzetti it Per maggiori informazioni tecniche di installazione o di funzionamento operativo il SERVIZIO DI CONSULENZA TECNICA POST VENDITA 0434 591121 l elenco completo dei centri di assistenza tecnica CAT lo trovi su www palazzetti it La Ditta Palazzetti non si assume alcuna responsabilit per eventuali errori del presente opuscolo e si ritiene libera di variare senza preavviso le caratteristiche dei propri prodotti Palazzetti accepts no liability for any mistakes in this handbook and is free to modify the features of its products without prior notice Die Firma Palazzetti bernimmt f r eventuelle Fehler in diesem Heft keine Verantwortung und behalt sich das Recht vor die Eigenschaften ihrer Produkte ohne Vorbescheid zu ndern Palazzetti d cline toute responsabilit en cas d erreurs dans la pr sente documentation et conserve la facult de modifier sans pr avis les caract risti
42. or of the forklift or other hoisting equipment is responsible for lifting the loads Prevent children from playing with the packaging components e g film and polystyrene Danger of suffocation 35 134 m G E 7 I PALAZZET TI 9 5 1 5 2 INSTALLATION SITE PREPARATION GENERAL INFORMATION The following paragraphs provide instructions that must be complied with in order to ensure maximum efficiency of the product purchased and safe operation The following instructions are however subordinate to compliance with any national regional and local laws and standards in force in the country where the product is installed SAFETY PRECAUTIONS Responsibility for work carried out in the place where the boiler is installed lies with the user the user is also responsible for making sure the installation checks are completed The user must abide by all local national and European safety requirements The appliance must be installed on floors with a suitable load bearing capacity The boiler assembly and dismantling instructions are reserved exclusively for specialist technicians Users should always contact our service centre to request work to be performed by qualified technicians Before having work performed by other technical personnel verify their effective technical competence Before starting to assemble or dismantle the boiler the installer must heed the safety precautions required by law specifica
43. ques de l appareil La empresa Palazzetti no se responsabiliza de los errores eventuales de este manual y tiene el derecho de modificar sin previo aviso las caracter sticas de sus productos Proizvajalec Palazzetti ne prevzema odgovornosti za morebitne napake v tem zvezku in si pridrzuje pravico do vnosa sprememb na svojih izdelkih Drez predhodnega obvestila Ufficio libretti Palazzetti cod 004772540 05 2013 Palazzetti PN Italy
44. reactivate the manual switch thermostats located on the facade of the boiler Fig 11 1 before resetting the alarm Then the boiler can be started again Fig 11 1 52 134 cod 004772540 05 2013 Palazzetti PN Italy USE AND amp MAINTENANCE PALAZZETTI 12 MAINTENANCE 12 1 SAFETY PRECAUTIONS Before performing any maintenance operations adopt the following precautions Make sure that all the parts of the boiler have cooled down Make sure that the ash is completely extinguished Use the personal protective equipment specified by directive 89 391 EEC Make sure that the main power switch is off Make sure that the power supply cannot be reconnected accidentally Unplug the cord from the socket on the wall Always use suitable tools for maintenance Once maintenance or repairs have been completed before operating the boiler again restore all protection features and reactivate all safety devices C amp 7 A suitable ash vacuum cleaner canister makes it simpler to clean the ash m Z 7 I 12 2 ROUTINE USER MAINTENANCE 12 2 1 Cleaning the inside of the firebox The boiler requires simple yet frequent and thorough cleaning in order to guarantee efficient and correct operation at all times AN Clean the boiler only when it s off and has cooled down Open the aesthetic door and then by using the three knobs open the combustion chamber door
45. rotection temperature a Use the arrow buttons J to go to the setup menu T and then press b Use the button to select the password 7 and then press to confirm c Select submenu L 3 and confirm by pressing d The value will flash change it using the buttons OFF 3 50 C e Press to confirm the settings Setting the value to OFF in step d disables the function 10 8 RESTART DELTA FUNCTION Restart delta configurations 2 3 and 4 is the number of degrees centigrade below the switch off temperature at which the stove switches on again automatically For example if the stove is set to switch off at 20 C Eco Mode active and Restart delta is set to 4 C the stove will switch on again when the temperature measured is less than or equal to 16 C Configuration 2 To set the restart delta value a Use the arrow buttons lt D to go to the setup menu Yl and then press 4 b Use the button to select the password 7 and then press to confirm Select submenu B and press to confirm d The value will flash change it using the and buttons US 506 e Press the button to confirm the set value Configuration 3 and 4 To set the restart delta value a Use the arrow buttons lt D to go to the setup menu Yl and then press b Use the button to select the password 7 and then press to confirm Select submenu B and press to
46. should only be switched off following the procedure described above Never switch the boiler off by unplugging it from the power supply 9 4 OPERATION WITH ROOM THERMOSTAT When the boiler is controlled by an external thermostat or timer thermostat the installer must have set configuration 1 In this configuration the boiler switches off when reaching the external thermostat setting or alternatively modulates output that is the boiler attempts to maintain the desired temperature while minimising fuel consumption when reaching the set water temperature The boiler switches on again automatically when the temperature falls below the value set on the external thermostat circuit closed CS Onfirst ignition or if the boiler has been switched off manually button the boiler needs to be started directly from the control panel The boiler will go off automatically even in the case the water temperature keeps growing notwithstanding the modulation mode In this case the boiler will ignite only if the difference between the selected and actual temperature is over 20 C Therefore if you choose this configuration we suggest that you select a high water temperature e g 70 C 9 5 OPERATION WITH ROOM PROBE ON THE BOILER The boiler can be switched on off manually or in programmed mode In this type of configuration the boiler modulates output according to the room temperature read by the probe on the boiler that is the boiler atte
47. thout the permission of PALAZZETTI The technical information illustrations and specifications included in this manual may not be disclosed Do not operate the appliance if any of the instructions provided in the manual are not understood if there are any doubts always contact specialist PALAZZETTI personnel for explanations PALAZZETTI reserves the right to modify the technical and or functional specifications of the boiler at any time without prior notice SYMBOLS The most important points in this manual are highlighted by the following symbols INSTRUCTION Instructions concerning correct boiler operation and the responsibilities of operators IMPORTANT This denotes very important information DANGER This specifies the behaviour required to prevent accidents or damage to materials INTENDED USE PALAZZETTI pellet boiler is a product designed for heating the home to be installed indoors with automatic operation exclusively on wood pellets This product is classified as apparatus of type B The appliance can be used to heat the water to a temperature lower than the boiling temperature It should be connected to a heating system sized on the basis of its performance and its power see technical features The pellet boiler works only with the door of the firebox closed and should never be opened during operation The appliance is not intended for use by people including children with limited physical sensorial
48. tti PN Italy USE AND amp MAINTENANCE PALAZZETTI 12 3 SPECIAL MAINTENANCE The pellet boiler is a solid fuel fired heater and as such requires annual maintenance to be performed by a Palazzetti Authorised Service Centre once a year preferably at the start of the season The purpose of such maintenance is to ensure all the components are in perfect working order If the control panel shows the VA symbols together immediately contact the Service Centre to have special maintenance performed on the boiler This warning can be reset temporarily by pressing the button and then starting the boiler again The warning will be shown again until special maintenance is performed by the Authorised Service Centre which will also reset the operating hour counter INSPECTION AND OR MAINTENANCE PLAN __ smo 1Wontu JGMONTHSJ 1 YEAR Bun pat x j Ash binicomparmen __ H Gms f x T Heat exchange __ xz TT ignition heatersoket x T_T TT Five gas mani L T x T Doorandbumpotgasets L o 1 T x Fus TGS Enum T_T T T responsibility of the Authorised Service Centre b AP 13 DECOMMISSIONING AND P Al 34 DISPOSAL Decommissioning and disposal of the boiler are the exclusive responsibility of the owner who must act in accordance with the laws in force in the country where the boiler is installed with regards to safety and en
49. ust be installed on floors with a suitable load bearing capacity Make sure that the flue and air intake duct arrangements correspond to the type of installation Do not make any electrical connections using temporary or uninsulated cables Make sure the electrical system is earthed correctly Before starting to assemble or dismantle the boiler the installer must heed the safety precautions required by law specifically A do not work in adverse conditions B always bein a fit mental physical state for working and make sure that personal protective equipment is in perfect working order always wear safety gloves always wear safety shoes always use electrically insulated tools make sure that the area being used for assembly and dismantling is clear of any obstacles WARNINGS Comply with the requirements specified in this manual Use always personal protective equipment and other means of protection e Before starting any maintenance work make sure that the boiler if it had been operating has cooled down e f even just one of the safety devices is not calibrated or not working the boiler must be considered out of service e Disconnect power before working on electrical or electronic parts and connectors WARNING FOR THE USER e Prepare the boiler installation site in accordance with local national and European regulations e As the boiler is a heating appliance it has very hot outside
50. vironmental protection The boiler may also be dismantled and disposed of by companies authorised to recover and dispose of the materials in question C INSTRUCTION always observe the standards in force in the country where the boiler is decommissioned as regards disposal of the materials and the waste disposal report where required IMPORTANT All dismantling operations for decommissioning the boiler must be performed when the boiler is off and disconnected from the power supply remove all electrical equipment separate the batteries fitted on the electronic boards have the structure of the boiler scrapped by an authorised company W IMPORTANT Dumping the boiler in accessible areas represents a serious hazard to people and animals Liabilitv for anv harm caused to people or animals alwavs lies with the owner When decommissioning the boiler the ce mark this manual and other documents relating to this boiler must be destroved cod 004772540 05 2013 Palazzetti PN Italy 55 134 PALAZZET TI 14 CONFIGURAZIONI DISPONIBILI AVAILABLE CONFIGURATIONS KONFIGURATIONEN ERHALTLICHCONFIGURATIONS DISPONIBLES CONFIGURACIONES DISPONIBLES KONFIGURACIJE NA VOLJO CONFIGURAZIONE 1 CONFIGURATION 1 KONFIGURATION 1 CONFIGURATION 1 CONFIGURACI N 1 Termostato esterno Wall thermostat Raumtemepratur Thermostat I I I I I I I I I I I I I I I I I I I I I I I I I I I Thermostat externe
Download Pdf Manuals
Related Search
Related Contents
Télécharger le manuel en PDF ATTO Technology 1180D User's Manual AristoFeed 30-4W MA6 AristoFeed 30-4W MA6 Philips Softone Lustre Lustre energy saving bulb 872790021186301 FireLock® Fire-Pac Série 745 Display Shelving Installation Instructions 取扱説明書 詳細版 Kombi-Mikrowelle Micro-ondes combi Forno a microonde Intellinet 560269 patch panel accessory Copyright © All rights reserved.